FAULT MESSAGES:- Sr No Problem Fault Message Action To Be Taken Window AC 1 Room Temp Sensor Faulty/ cable cut E1 Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor. 2 Coil Temp Sensor Faulty/ cable cut E2 Check coil sensor wiring, Change coil sensor, Track/ SMD on PCB in series of coil sensor. VDS52 1 Coil Temp Sensor Faulty/ cable cut F8 Check coil sensor wiring, Change coil sensor, Track/ SMD on PCB in series of coil sensor. 2 IDU Motor Faulty/ Cable cut/ feedback not received F6 Check motor wires, Feedback wires, Motor Jam, Track burn/ SMD burn in series with feedback signal. 3 Room Temp Sensor Faulty/ cable cut F1 Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor. VKS52/VZS32/VGS33/VGS53 1 Coil Temp Sensor Faulty/ cable cut Green Led blink along with operation LED Check coil sensor wiring, Change coil sensor, Track/ SMD on PCB in series of coil sensor. 2 Room Temp Sensor Faulty/ cable cut Green Led blink along with operation LED Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor. 3 IDU Motor Faulty/ Cable cut/ feedback not received Only Green Led blink after 1 min Check motor wires, Feedback wires, Motor Jam, Track burn/ SMD burn in series with feedback signal.
7

FAULT MESSAGES:- Sr NoProblemFault Message Action To Be Taken Window AC 1Room Temp Sensor Faulty/ cable cutE1 Check room sensor wiring, Change room sensor,

Dec 15, 2015

Download

Documents

Dana Pease
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: FAULT MESSAGES:- Sr NoProblemFault Message Action To Be Taken Window AC 1Room Temp Sensor Faulty/ cable cutE1 Check room sensor wiring, Change room sensor,

FAULT MESSAGES:-Sr No Problem Fault Message Action To Be Taken

       

Window AC

1 Room Temp Sensor Faulty/ cable cut E1Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor.

2 Coil Temp Sensor Faulty/ cable cut E2Check coil sensor wiring, Change coil sensor, Track/ SMD on PCB in series of coil sensor.

VDS52

1 Coil Temp Sensor Faulty/ cable cut F8Check coil sensor wiring, Change coil sensor, Track/ SMD on PCB in series of coil sensor.

2IDU Motor Faulty/ Cable cut/ feedback not received

F6Check motor wires, Feedback wires, Motor Jam, Track burn/ SMD burn in series with feedback signal.

3 Room Temp Sensor Faulty/ cable cut F1Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor.

VKS52/VZS32/VGS33/VGS53

1 Coil Temp Sensor Faulty/ cable cutGreen Led blink along with operation LED

Check coil sensor wiring, Change coil sensor, Track/ SMD on PCB in series of coil sensor.

2 Room Temp Sensor Faulty/ cable cutGreen Led blink along with operation LED

Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor.

3IDU Motor Faulty/ Cable cut/ feedback not received

Only Green Led blink after 1 min

Check motor wires, Feedback wires, Motor Jam, Track burn/ SMD burn in series with feedback signal.

Page 2: FAULT MESSAGES:- Sr NoProblemFault Message Action To Be Taken Window AC 1Room Temp Sensor Faulty/ cable cutE1 Check room sensor wiring, Change room sensor,

FAULT MESSAGES

Sr No Problem Fault Message Action To Be TakenETS/EYS/VYS32/52

1 Coil Temp Sensor Faulty/ cable cut F8Check coil sensor wiring, Change coil sensor, Track/ SMD on PCB in series of coil sensor.

2IDU Motor Faulty/ Cable cut/ feedback not received

F6Check motor wires, Feedback wires, Motor Jam, Track burn/ SMD burn in series with feedback signal.

3 Room Temp Sensor Faulty/ cable cut F7Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor.

VPS/VQS/VTS/VBS/VKS/VRS 23/33/53/35/55

1 Blower Motor Error H6Check motor wires, Feedback wires, Motor Jam, Track burn/ SMD burn in series with feedback signal.

2 Coil Sensor Error F2Check coil sensor wiring, Change coil sensor, Track/ SMD on PCB in series of coil sensor.

3 Temp Sensor Error F1Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor.

4Check Connector 04 ( Jumper on

PCB )C5 Clean & Place connector 04 properly. 

SAC TCL

1 Blower Motor Error E6Check motor wires, Feedback wires, Motor Jam, Track burn/ SMD burn in series with feedback signal.

2 Coil Sensor Error E2Check coil sensor wiring, Change coil sensor, Track/ SMD on PCB in series of coil sensor.

3 Temp Sensor Error E1Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor.

Page 3: FAULT MESSAGES:- Sr NoProblemFault Message Action To Be Taken Window AC 1Room Temp Sensor Faulty/ cable cutE1 Check room sensor wiring, Change room sensor,

FAULT MESSAGES – Inverter AC

ODU FAULT MESSAGESSr No Problem Red Light Yellow Light Green Light Action To Be Taken

1Outdoor Evaporator Temperature Sensor Malfunction

5 Blink    Check sensor wiring, Connector of Sensor,  Change outdoor sensor, Track/ SMD on PCB in series of  sensor.

2Outdoor Ambient Temperature Sensor Malfunction

6 Blink    Check sensor wiring, Connector of Sensor,  Change outdoor Ambient sensor, Track/ SMD on PCB in series of  sensor.

3 Overcurrent Protection   5 Blink  Check Compressor Wiring for Short Ckt, Room Sensor/ Wiring/ Connector faulty.

4 IPM Protection   4 Blink  If fault is permanent after 6 times, Check the PCB for Module Burnt/ Track Burnt/ Any damage. 

5 Communication Malfunction     Off

Check the Communication cable between IDU & ODU for Cable Cut/ Loose connection/ Any other High Power cable adjascent to the AC cable.

IDU FAULT MESSAGES  Problem   Error Code   Action To Be Taken1 Jumper Cap Malfunction   C5   Clean & Place connector 04 properly. 

2 Indoor Sensor Malfunction   FP  Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor.

3 Indoor Fan Failure   H6  Check motor wires, Feedback wires, Motor Jam, Track burn/ SMD burn in series with feedback signal.

4 IPM Protection   H5  If fault is permanent after 6 times, Check the PCB for Module Burnt/ Track Burnt/ Any damage. 

Page 4: FAULT MESSAGES:- Sr NoProblemFault Message Action To Be Taken Window AC 1Room Temp Sensor Faulty/ cable cutE1 Check room sensor wiring, Change room sensor,

Connector 04 ( C5 Error In VPS )

Page 5: FAULT MESSAGES:- Sr NoProblemFault Message Action To Be Taken Window AC 1Room Temp Sensor Faulty/ cable cutE1 Check room sensor wiring, Change room sensor,

WAC Control PCB

SMD in series with Room sensor signal.

Page 6: FAULT MESSAGES:- Sr NoProblemFault Message Action To Be Taken Window AC 1Room Temp Sensor Faulty/ cable cutE1 Check room sensor wiring, Change room sensor,

VDR 10K561 ( Over-Voltage protector )

WAC Power PCB

Relays Can Damage Due To:-

1 Short Circuit in wiring2 Wrong Wiring3 Loose connections at Terminals ( Sparking )

Page 7: FAULT MESSAGES:- Sr NoProblemFault Message Action To Be Taken Window AC 1Room Temp Sensor Faulty/ cable cutE1 Check room sensor wiring, Change room sensor,

F6 Or H6 Error in SAC

Can Be Due to:-1Motor Wires Cut2Feedback wires cut3Motor Jam ( Feedback signal not received)4Track Burn on PCB ( Feedback not reach to MICON5Faulty Connector of Feedback.

Motor Feedback connector ( 3 Pin)Includes Vcc, Feedback & Gnd.( Check 5V between Vcc & Gnd )