Farabaugh Engineering and Testing Inc. Project No. T281-08 Report Date: October 30, 2008 Total Pages (inclusive): 18 ASTME 1592 STANDARD TEST METHOD FOR STRUCTURAL PERFORMANCE OF SHEET METAL ROOF AND SIDING SYSTEMS BY UNIFORM STATIC AIR PRESSURE DIFFERENCE 7.2 ROOF PANEL 36" WIDE X 0.032" ALUMINUM FOR PETERSEN ALUMINUM CORP. 1005 TONNE RD. ELK GROVE VILLAGE, IL 60007 Daniel G. Farabaugh, PE ACCREDITED LABORATORY TL·186 ACCREDITED LABORATORY M ED ACCREDI TED MIAMI.DADE LABORATORY r. DANiel G. FARABAUGH, P.E. 255 Samders Station Rd. Trafford, PA 15085 .y' (412) 373-9238 e TEXAS DEPARTMENT 103/ og OF INSURANCE - , , ACCREDI TED LABORATORY 401 Wide Drive, MCKeesport, PA 15135 (412) 751-4001 FAX (412) 751-4003 WWW.FETLABS.COM I
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Farabaugh Engineering and Testing Inc.
Project No. T281-08
Report Date: October 30, 2008
Total Pages (inclusive): 18
ASTME 1592 STANDARD TEST METHOD FOR
STRUCTURAL PERFORMANCE OF SHEET METAL ROOF AND SIDING SYSTEMS BY UNIFORM STATIC AIR PRESSURE DIFFERENCE
STRUCTURAL PERFORMANCE OF SHEET METAL ROOF AND SIDING SYSTEMS BY UNIFORM STATIC AIR PRESSURE DIFFERENCE
Purpose
This test method covers the evaluation ofthe structural performance of Sheet Metal Panels and Anchor to Panel Attachments for roof or siding systems under uniform static air pressure difference.
Test Date
Test #1 (Specimen "A") - 10/23/08
Test #2 (Specimen "B") - 1 0/28/08
Test Specimen
Manufacturer: Petersen Aluminum Corp. 1 005 Tonne Rd. Elk Grove Village, IL 60007