Top Banner
Model T9000 Electro-Pneumatic Pressure Controller Features Common Features of the T9000 Products • Fully functional keypad and display. • Backlit Liquid Crystal display screen. • Output pressure displays in psig, BAR, kPa, or user-defined pressure units. • Independently adjustable PID tuning coefficients. • Reverse acting capability for analog input and output signals. • Select Current or Voltage mode for input signal or optional analog channels using the keypad. • RFI/EMI protection eliminates electromagnetic and radio interference. Operating Principles The Model T9000 Series Pressure Controllers have a closed-loop, integrated, microprocessor control system that regu- lates outlet pressure. You can control the output from the Model T9000 products using the keypad or from an analog control signal. You can control the output from the Model T9000D using the keypad and through DeviceNet TM Communication network. The Feed and Bleed Solenoid Valves con- trol pressure in the Signal Chamber of the Booster Section. A pressure sensor mea- sures the outlet pressure and provides a feedback signal to the Electronics Section. Any variation in pressure between the set- point and the outlet pressure activates the Feed and Bleed Solenoid Valves to correct the output pressure. B Model T9000 T9000 T9020 T9040 T9060 T9080 Specialists in Valves, Controls, Pneumatics, Fluid Measurement Phone: (203) 261-6711 Fax: (203) 261-8331 • www.okcautomation.com
4

Fairchild Model T9000 Electro-Pneumatic Pressure Controller · Model T9000 Electro-Pneumatic Pressure Controller ... (ISA S51.1) Adjustable from 0 to ... Fairchild Model T9000 Electro-Pneumatic

Oct 07, 2018

Download

Documents

doduong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Fairchild Model T9000 Electro-Pneumatic Pressure Controller · Model T9000 Electro-Pneumatic Pressure Controller ... (ISA S51.1) Adjustable from 0 to ... Fairchild Model T9000 Electro-Pneumatic

Model T9000 Electro-Pneumatic Pressure Controller

FeaturesCommon Features of the T9000 Products•Fullyfunctionalkeypadanddisplay.•BacklitLiquidCrystaldisplayscreen.•Outputpressuredisplaysinpsig,BAR, kPa,oruser-definedpressureunits.•IndependentlyadjustablePIDtuning coefficients.•Reverseactingcapabilityforanaloginput andoutputsignals.•SelectCurrentorVoltagemodeforinput signaloroptionalanalogchannelsusing thekeypad.•RFI/EMIprotectioneliminates electromagneticandradiointerference.

Operating PrinciplesTheModelT9000SeriesPressureControllershaveaclosed-loop,integrated,microprocessorcontrolsystemthatregu-latesoutletpressure.YoucancontroltheoutputfromtheModelT9000productsusingthekeypadorfromananalogcontrolsignal.YoucancontroltheoutputfromtheModelT9000DusingthekeypadandthroughDeviceNetTMCommunicationnetwork.

TheFeedandBleedSolenoidValvescon-trolpressureintheSignalChamberoftheBoosterSection.Apressuresensormea-surestheoutletpressureandprovidesafeedbacksignaltotheElectronicsSection.Anyvariationinpressurebetweentheset-pointandtheoutletpressureactivatestheFeedandBleedSolenoidValvestocorrecttheoutputpressure.

BModel T9000

T9000

T9020

T9040

T9060

T9080

Specialists in Valves, Controls, Pneumatics, Fluid Measurement

Phone: (203) 261-6711Fax: (203) 261-8331 • www.okcautomation.com

Page 2: Fairchild Model T9000 Electro-Pneumatic Pressure Controller · Model T9000 Electro-Pneumatic Pressure Controller ... (ISA S51.1) Adjustable from 0 to ... Fairchild Model T9000 Electro-Pneumatic

BModel T9000

T9000

T9020

T9040

T9040Flow Rate (SCFM)110(187m3/HR)@150psig,[10BAR],(1000kPa)supply

Exhaust Flow (SCFM)55(94m3/HR)@60psig,[4BAR],(400kPa)downstreampressure

T9020Flow Rate (SCFM)90(153m3/HR)@150psig,[10BAR](1000kPA)supply

Exhaust Flow (SCFM)45(77m3/HR)@60psig[4BAR],(400kPa)downsteampressure

T9000Flow Rate (SCFM)1(1.7m3/HR)@150psig,[10BAR],(1000kPa)supply

Model T9000 Electro-Pneumatic Transducer

0

30

60

90

120

150

-10 0 10 20 30 40 50 60 70 80 90 100

Supply Pressure = 150 PSIG

Setpoint = 30 PSIG

Setpoint = 60 PSIG

Setpoint = 90 PSIG

Setpoint = 120 PSIG

Air Flow, SCFM

Out

put P

ress

ure,

PSI

G

Flow CharacteristicsT9020-4072N4NFS Pressure Controller

0

30

60

90

120

150

-20 0 20 40 60 80 100 120 140

Supply Pressure = 150 PSIG

Setpoint = 30 PSIG

Setpoint = 60 PSIG

Setpoint = 90 PSIG

Setpoint = 120 PSIG

Air Flow, SCFM

Out

put P

ress

ure,

PSI

G

Flow CharacteristicsT9040-4074N4FJT Pressure Controller

Specialists in Valves, Controls, Pneumatics, Fluid Measurement

Phone: (203) 261-6711Fax: (203) 261-8331 • www.okcautomation.com

Page 3: Fairchild Model T9000 Electro-Pneumatic Pressure Controller · Model T9000 Electro-Pneumatic Pressure Controller ... (ISA S51.1) Adjustable from 0 to ... Fairchild Model T9000 Electro-Pneumatic

Flow Rate (SCFM)220(375m3/HR)@150psig,[10BAR],(1000kPa)supply

Exhaust Flow (SCFM)110(187m3/HR)@60psig[4BAR],(400kPa)downsteampressure

Flow Rate (SCFM)700(1190m3/HR)@150psig,[10BAR],(1000kPa)supply

Exhaust Flow (SCFM)350(600m3/HR)@60psig[4BAR],(400kPa)downsteampressure

T9060 T9080

Model T9000 Electro-Pneumatic Transducer

0

30

60

90

120

150

0 50 100 150 200 250

Supply Pressure = 150 PSIG

Setpoint = 30 PSIG

Setpoint = 60 PSIG

Setpoint = 90 PSIG

Setpoint = 120 PSIG

Air Flow, SCFM

Out

put P

ress

ure,

PSI

G

Flow CharacteristicsT9060-4074N4FNT Pressure Controller

BModel T9000

Specialists in Valves, Controls, Pneumatics, Fluid Measurement

Phone: (203) 261-6711Fax: (203) 261-8331 • www.okcautomation.com

Page 4: Fairchild Model T9000 Electro-Pneumatic Pressure Controller · Model T9000 Electro-Pneumatic Pressure Controller ... (ISA S51.1) Adjustable from 0 to ... Fairchild Model T9000 Electro-Pneumatic

Model T9000 Electro-Pneumatic Transducer

InstallationForoperatinginstructions,refertothecorrespondingFairchildOperation and Maintenance Instructions,OM-500T90FI,OM-500T90AB,OM-500T90AO,OM-500T90DB,OM-500T90DI,OM-500T90DO.

Forinstallationinstructions,refertoII-500T9000.

Catalog InformationSpecificationsSupply Pressure1200psig,[14BAR],(1400kPa)MaximumPneumatic Outputs psig: 0-30 0-75 0-150 [BAR]: [0-2] [0-5] [0-10] (kPa): (0-200) (0-500) (0-1000) Minimum Span psig: 12 30 60 [BAR]: [0.8] [2.0] [4.0] (kPa): (80) (200) (400)

Input Signal4-20mA,0-10VDCFlow Rate1-700SCFM(Selectdesiredconfiguration)Exhaust Flow 1-350SCFM(Selectdesiredconfiguration)

Air Consumption 0@steadystateoutputwithDeadband@1%ofFullScale Supply Pressure EffectNoMeasurableEffectElectrical Supply24VDC±10%Power ConsumptionLessthan5wattsAnalog Output Signal / Impedence4-20mA/500ohmsMaximum,0-10VDC/400ohmsMinimumDeadband (ISA S51.1)Adjustablefrom0to10%ofFullScaleUnit Accuracy (ISA S51.1)Lessthan0.50%OutputSpanFrequency [email protected](typicalbutdependsonspecificT9000productconfiguration)Vibration EffectLessthan1%ofSpanunderthefollowingconditions:[email protected]@10g’sRFI/EMI EffectLessthan0.5%.EMCDirective89/336/EECEuropeanNormsEN50081-2&EN50082-2.Temperature Range0°Fto+160°F,(-18°Cto+71°C)Materials of Construction BodyHousing........Polymer,ChromateTreatedAluminumTrim........................................................ ZincPlatedSteelElastomers......................................... Nitrile,FluorocarbonFinish........................................................................Epoxy1 Supply Pressure must be no less than 5 psig, [0.35 BAR], (35 kPa) above

maximum output.

BModel T9000

Catalog Number T90

Flow Rate1 SCFM (Basic Transducer) ....... 0090 SCFM ……………………......... 20110 SCFM …………………......... 40220 SCFM……………………........ 60700 SCFM ……………………....... 80

Input0-10 VDC . . . . . . . . . . . . . . . . . . . . . . . 04-20 mA . . . . . . . . . . . . . . . . . . . . . . . . 4DeviceNet TM . . . . . . . . . . . . . . . . . . . . . D

Output0-30 psig. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 040-75 psig. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 050-150 psig. . . . . . . . . . . . . . . . . . . . . . . . . . . . 07[0-2.0 BAR] . . . . . . . . . . . . . . . . . . . . . . . . . . . 14[0-5.0 BAR] . . . . . . . . . . . . . . . . . . . . . . . . . . . 15[0-10.0 BAR] . . . . . . . . . . . . . . . . . . . . . . . . . . 17(0-200 kPa). . . . . . . . . . . . . . . . . . . . . . . . . . . 24(0-500 kPa). . . . . . . . . . . . . . . . . . . . . . . . . . . 25(0-1000 kPa). . . . . . . . . . . . . . . . . . . . . . . . . . 27

Port Size1/4" NPT (T9000,20,40 only) . . . . . . . . . . . . . . . . 023/8" NPT (T9020,40 only) . . . . . . . . . . . . . . . . . . 031/2” NPT (T9020,40 only) . . . . . . . . . . . . . . . . . . 043/4” NPT (T9060,80 only) . . . . . . . . . . . . . . . . . . 061” NPT (T9080 only) . . . . . . . . . . . . . . . . . . . . . . 08

Port ThreadsNPTF Thread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBSPT Thread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UBSPP Thread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H

Feedback OptionNone. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N0-10 VDC Analog Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04-20 MA Analog Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-10 VDC Feedback Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54-20 MA Feedback Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

ElastomersNitrile (Not available in T9040). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NFluorocarbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J

Power Failure ModeFreeze (Maintains Setpoint) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F

Exhaust PortTapped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E

Remote Pressure Sensing Capability (see table below)

Unique Feature of the T9000D•DeviceNetTMCommunicationsconnecttheModelT9000D toadigitalnetworktoincreasefunctionalflexibility, installationspeed,andreducesystemwiringcost.

Available Options for the T9000 Series Transducer•Optionalanalogoutputchannelconfiguredasanoutput pressuremonitororasauser-definedoutput.•ExternalPneumaticFeedbackporttosensedownstream pressure.(SeeCablesandAccessoriestable)•OptionalFeedbackInputChannelconfigurabletocontrol setpoint,externalprocessvariable,oracceptauser definedinput.(Consultfactoryforavailability.)

T9000 Cables and Accessories (sold separately)

Part Number Description 032-IPI-018-2Straight,Shielded6pinFemale032-IPI-019-2Rightangle,Shielded6pinFemale21655-1N1/8-27NPTFRemotePressureSensorfitting21655-1U1/8-28BSPTRemotePressureSensorfitting

Specialists in Valves, Controls, Pneumatics, Fluid Measurement

Phone: (203) 261-6711Fax: (203) 261-8331 • www.okcautomation.com