Top Banner
Failur Failur es es
29

Failures

Jan 03, 2016

Download

Documents

elmo-barr

Failures. The Ramsgate Walkway Collapse 1964. 1994 6 killed. 4 people died. The Ramsgate Walkway Collapse. The Ronan Point Collapse 1968. 4 people killed. Code of practice used : CP114 Structural Design of Reinforced Concrete Buildings. Stability and robustness. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Failures

FailuresFailures

Page 2: Failures

1994 6 killed

The Ramsgate Walkway Collapse 1964The Ramsgate Walkway Collapse 1964

4 people died

Page 3: Failures

Bearing Stub axle

Assumed position of resultant of forces on axle

Ramsgate Walkway support

The Ramsgate Walkway CollapseThe Ramsgate Walkway Collapse

Page 4: Failures

The Ronan Point Collapse 1968

Code of practice used :

CP114 Structural Design of Reinforced Concrete Buildings

4 people killed

Page 5: Failures

Stability and robustnessStability and robustness

Buildings of this type can be very robust

Page 6: Failures

The Cleddau (Milford Haven) The Cleddau (Milford Haven) Bridge Collapse 1970 Bridge Collapse 1970

4 people died when the bridge collapsed under construction.

The diaphragm above the pier buckled causing the then cantilevering section of the deck to collapse.

Page 7: Failures

The Cleddau (Milford Haven) The Cleddau (Milford Haven) Bridge Collapse 1970 Bridge Collapse 1970

At that time the use of finite element analysis was not well developed.

Doing a shell element model with non-linear geometry and non-linear material behaviour would have been a major achievement.

Nowadays it would be quite feasible and would certainly give warnings of the problem.

Page 8: Failures

Failures

Charles de Gaulle Airport 2004

Main reason for the collapse: lack of ductility to resist dynamic punching shear

4 deaths

Page 9: Failures

Punching shear failure

Page 10: Failures

Failures

Millennium Footbridge, London 2000

Synchronous lateral excitation

Page 11: Failures

The Hartford Connecticut Civic Center Roof Collapse 1978

Happened at night - no deaths

Page 12: Failures

Two major modelling errors were the main sources of this collapse. Second order effects (non-linear geometry) were important but not included in the model resulting in lower stiffness and higher internal forces than predicted.

The Hartford Connecticut Civic Center Collapse

Page 13: Failures

Secondly the centroidal axes of the members were not coincident at the joints. This caused significant underestimates of moments in the members.

The Hartford Connecticut Civic Center Collapse

Page 14: Failures
Page 15: Failures

Sleipner Platform before collapse - 1991

No deaths but very high financial loss

Page 16: Failures
Page 17: Failures

Sleipner - Plan

Page 18: Failures

Sleipner - Mesh at Tricell

Page 19: Failures

Sleipner - Detail of Mesh at Tricell Junction

Page 20: Failures

0.5 m 4.5 m

Internal hydrostatic pressure

Plan of tricell

Page 21: Failures

Calculation (checking model) for shear stress in tricell wall of Sleipner Platform

Operating Conditions: Span of Wall - 4.5 m

Effective depth - 500 mm, Pressure head 67.0 m

Pressure at 67 m depth: p = gh = 1000 x 9.81 x 67 = 66x 104 N/m

= p x area = 66x 104 x 4.5 x 1.0 = 3000 x 103 NLoad on 1.0 m strip at 67 m depth: W

W

Max shear: V = W/2 = 3000 x 103 /2 = 1500 x 103 N

500

1000 Shear stress in concrete: vc = V/(bd) = 1500x103/(500x 1000) = 3 N/mm2

Maximum design shear stress (BS 8110 for unreinforced section): vc (BS8110) = 0.91 N/mm2

Page 22: Failures

Sleipner Collapse

The collapse was due to the choice of an inadequate mesh of 3D elements for the walls of the tricells. The estimate of shear stress in the wall was about 1/3 of a realistic value.

The computational model was not valid

Page 23: Failures

Hyatt Regency walkway collapseHyatt Regency walkway collapse

1981 - 114 dead

Page 24: Failures

Hyatt Regency

Error in understanding the load path for the hangers - Modelling error

Fault in designer/contractor relationship

Lack of robustness

Page 25: Failures

The Tay Bridge Disaster 1879• Completed in February

1878.

• Longest bridge in the world at time - 2 miles.

Page 26: Failures

View showing collapsed spans.

• To date - worst structural accident in the British Isles.

77 people killled

Page 27: Failures
Page 28: Failures

Pier No. 5 Looking North

Lifting of windward column.

(Dundee City Council, Central Library, Photographic Collection)

 

Page 29: Failures

THE END