FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 Abdulmohsen Al-Sahli, Avtandil Khalil Bairamov, Abdulaziz Al-Meshari, Gys Van Zyl, and Ali Al-Shawaf
21

FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

Aug 19, 2018

Download

Documents

lycong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES

April 26, 2017

Abdulmohsen Al-Sahli, Avtandil Khalil Bairamov, Abdulaziz Al-Meshari, Gys Van Zyl, and Ali Al-Shawaf

Page 2: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 1

OUTLINE

• Background

• Process Description

• Schematic Diagram of Damage Locations

• Investigation

Visual Examination

Chemical Analysis

Metallography

SEM/EDS

• Conclusions

Page 3: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 2

BACKGROUND

A petrochemical plant was shut down due to tubes leaks in a waste heat boiler (WHB).

The failed WHB has been in operation for about 20 years, without any previous failure.

Following the incident, inspection activities revealed the following:

• Leaks were observed at 7 tubes.

• Localized damage was observed on 70% of the ferrules.

• Leakages were always observed after the end of the ferrules.

• Tubes were observed to be externally covered with a deposit.

A leaked tube and another severely thinned tube from the WHB were analyzed to determine

the failure mechanism and contributing factors.

Page 4: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 3

PROCESS DESCRIPTION

Waste Heat Boiler

BFW Inlet

SH Header

Process Gas Inlet Process Gas Outlet

Fu

rth

er

Pro

ce

ssin

g

Steam Drum

Page 5: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 4

SCHEMATIC DIAGRAM OF DAMAGE LOCATIONS

The damage has been observed to be confined to areas after the ferrule’s end.

Page 6: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

INVESTIGATION

FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES

Page 7: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 6

VISUAL EXAMINATION OF THE LEAKED TUBE

The leaked tube sample in as-received condition.

Pin HoleNo signs of corrosion

Localized

Corrosion

Page 8: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 7

THE INTERNAL SURFACE OF THE LEAKED TUBE

Pin HoleLocalized Wall

Thinning

No Signs of Corrosion

The internal surfaces of the leaked tube.

Signs for Damage

Initiation

Page 9: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 8

VISUAL EXAMINATION OF THE SEVERELY THINNED TUBE

No signs of corrosionLocalized Corrosion

The severely tube sample in as-received condition.

Page 10: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 9

INTERNAL SURFACE OF THE THINNED TUBE

No Signs of Corrosion

Threads

White Lines

The internal surfaces of the thinned tube.

Page 11: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 10

TUBES MATERIAL CONFIRMATION

Element Sample ASTM SA213 T12*

C 0.13 0.05–0.15

Mn 0.44 0.30-0.61

Si 0.24 0.50

Cr 0.85 0.80–1.25

Mo 0.44 0.44–0.65

Fe Balance Balance

P 0.040 0.025

S 0.012 0.025

*Maximum unless otherwise indicated

XRF & C/S analyses (wt.%).

The chemical composition of the materials closely matches the chemical composition of

ASTM SA 213 T12.

Page 12: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 11

CHEMICAL COMPOSITION OF DEPOSIT FOUND ON TUBES EXTERNAL SURFACES

Element Sample

C 0.04

Mg 0.04

Al 0.08

Si 0.17

P 0.03

S 0.02

Cl 0.02

Ca 0.04

Cr 0.61

Mn 0.34

Fe Balance

Ni 0.08

Cu 0.10

Mo 0.42

XRF & C/S analyses (wt.%).

Page 13: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 12

CROSS SECTION OF THE LEAKED TUBE

Micrographs showing severe localized corrosion from the outer surface.

Localized AttackOuter Surface

Inner Surface

Page 14: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 13

MICROSTRUCTURAL ANALYSIS OF TUBES

Micrographs of the leaked tube, as polished (left) and etched with 2% Nital (right).

Page 15: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 14

SEM/EDS OF TUBE EXTERNAL SURFACE NEAR PINHOLE

Spectrum C O Na Si S Fe Cu

A1 2.51 22.79 0.22 0.20 73.53 0.75

A2 2.59 34.73 0.18 0.33 62.17

Page 16: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 15

SEM/EDS OF TUBE INTERNAL SURFACE AT PINHOLE

Spectrum C O Na Al Si P Ca Mn Fe Mo

A1 1.17 32.02 0.46 0.38 65.13 0.83

P1 2.45 33.54 0.66 0.15 0.90 5.87 0.31 7.30 48.82

P2 2.13 33.27 1.02 0.35 0.31 61.54 1.38

A2 2.55 35.51 0.18 0.28 0.12 61.37

Page 17: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 16

SEM/EDS OF TUBE EXTERNAL SURFACE AT PINHOLE

Spectrum C O Si S Cl Fe Cu Mo

A1 1.76 35.54 0.65 0.42 60.99 0.64

A2 3.86 32.57 0.64 0.68 62.26

A3 1.30 31.87 0.31 65.72 0.80

Page 18: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

CONCLUSIONS

FAILURE ANALYSIS OF WASTE HEAT BOILER

Page 19: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 18

FAILURE MECHANISM

The experimental observations suggest that the tubes failed by caustic gauging.

Page 20: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

No. 19

CONCLUSIONS

• The experimental observations suggest that the tubes failed by caustic gauging.

• The damage is confined to a small portion of the tubes where deposit formation has been

observed.

• Deposition resulted mostly due to the quality of BFW.

• Reduction of temperature gradient at the entrance of the boiler could help in reducing

deposition.

Page 21: FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES 2017/PD1/6. A... · FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES April 26, 2017 ... • Leaks were observed at 7 tubes. • Localized damage

THANK YOU!

FAILURE ANALYSIS OF WASTE HEAT BOILER TUBES