TECHNICAL FEATURES
MODEL 1402.2 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2
5002.4 6002.4 7002.4
Nominal cooling capacity kW 46.1 52.4 65.1 79.1 86.2 113.6 125.3
134.8 171 200 218.5
Absorbed power kW 16.4 20.1 21.6 28.1 33 39.5 44.4 49.9 53.9
69.1 77.8
EER - 2.81 2.61 3.01 2.81 2.61 2.88 2.82 2.70 3.17 2.90 2.81
Energy classification (2) - B C A B C B B C A B B
Nominal heating capacity kW 46.8 53.9 65 80.4 89.1 119.1 132.7
143 169.8 205.7 226.7
Absorbed power kW 13.7 16.8 19.1 25 29.6 35.6 41.4 45.8 49.8
63.3 70.6
COP - 3.41 3.21 3.41 3.21 3.01 3.35 3.21 3.12 3.41 3.25 3.21
Energy classification (2) - A B A B C B B C A B B
Power supply (50 Hz) V 400.3 + N 400.3 + N 400.3 + N 400.3 + N
400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 +
N
Nominal supply air flow m3/h 9,000 10,200 11,500 14,000 15,500
21,000 23,000 25,000 28,500 34,000 37,000
Available static pressure Pa 100 100 125 125 125 150 150 150 175
175 175
Dimensions(length x width x height) mm
2.886 x 2.219 x 1.240
2.886 x 2.219 x 1.240
2.886 x 2.219 x 1.240
2.886 x 2.219 x 1.240
2.886 x 2.219 x 1.240
3.900 x 2.219 x 1.900
3.900 x 2.219 x 1.900
3.900 x 2.219 x 1.900
4.330 x 2.219 x 2.240
4.330 x 2.219 x 2.240
4.330 x 2.219 x 2.240
Net weight kg 944 975 1,023 1,043 1,072 1,594 1,704 1,721 2,454
2,624 2,628
MODEL 1402.2 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2
5002.4 6002.4 7002.4
Nominal cooling capacity (1) kW 64.1 71.1 87.4 103.5 116.4 152
164.8 178.4 223.7 270.2 292.7
Recovery cooling capacity kW 17.7 18.2 20.8 21.4 25.3 34.8 35.4
38.4 46.3 58.7 66.9
Main circuits cooling capacity kW 46.4 529 66.9 82.1 91.1 117.3
129.5 140.1 177.5 211.5 225.8
Absorbed power kW 20.3 23.9 26.8 34.4 41.6 49.7 55.7 63.1 66 87
97.4
EER - 3.16 2.97 3.26 3.01 2.81 3.06 2.96 2.83 3.39 3.11 3.01
Energy classification (2) - A B A A B A B B A A A
Nominalheating capacity (1) kW 67.4 76.8 89.2 106 120.8 163.8
177.6 193.5 223.9 278.9 311.8
Recovery heating capacity kW 17.8 18.4 20.7 21.6 25.3 41 41.4
46.1 45.6 58.5 78
Main circuits heating capacity kW 49.6 58.4 68.5 84.4 95.5 122.8
136.2 147.4 178.2 220.4 233.7
Absorbed power kW 17.1 19.9 22.7 28.2 34.4 42.4 48.6 54.8 56.1
73.6 84.1
COP - 3.94 3.85 3.92 3.76 3.51 3.86 3.66 3.53 3.99 3.79 3.71
Energy classification (2) - A A A A A A A A A A A
Power supply (50 Hz) V 400.3 + N 400.3 + N 400.3 + N 400.3 + N
400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 +
N
Nominal supply air flow m3/h 9,000 10,200 11,500 14,000 15,500
21,000 23,000 25,000 28,500 34,000 37,000
Available static pressure Pa 100 100 125 125 125 150 150 150 175
175 175
Dimensions (length x width x height) mm
3,968 x 2,219 x 1,240
3,968 x 2,219 x 1,240
3,968 x 2,219 x 1,240
3,968 x 2,219 x 1,240
3,968 x 2,219 x 1,240
5,845 x 2,219 x 1,900
5,845 x 2,219 x 1,900
5,845 x 2,219 x 1,900
6,300 x 2,219 x 2,240
6,300 x 2,219 x 2,240
6,300 x 2,219 x 2,240
Net weight kg 1,315 1,353 1,417 1,445 1,531 2,373 2,519 2,549
3,317 3,456 3,491
STD
RCF
(1) For an air renovation flow of 90%.(2) According to EUROVENT
classification
Note: KUBIC VRC equipment has the same capacity as STDs and the
same dimensions as RCFs. For the GB modules, query configuration
and available capacity.
COMPACT, LIGHTWEIGHT AND MODULAR
2017 RANGE
A DIFFERENTROOFTOP
ANDALUCÍA
ARAGÓN
ASTURIAS
BALEARES
CANTABRIA
CASTILLA-LA MANCHAVALENCIA
CASTILLA Y LEÓNCATALUÑA
EXTREMADURA
GALICIA
LA RIOJA
MADRID
MURCIA
NAVARRA
PAÍS VASCO
Vilanova i la Geltrú
Arenys de Mar
Factory in Vilanovai la Geltrú (Spain)
Factory in Arenys de Mar (Spain)
NEW
NEW
HIPLUS AIRE ACONDICIONADO S.L.
Masia Torrents, 2Tel. +34 938 934 912Fax +34 938 939 615
08800 Vilanova i la GeltrúBarcelona, Spain
www.hitecsa.comwww.adisaheating.com
ROOFTOP TYPE UNITSWITH AXIAL FANS
Basic equipment (return air only)with standard TH TUNE
thermostat(optional PGD and MINI PGD)
KUBIC STDStandard Unit
Available modules
The thermodynamic heat recovery module includes an additional
refrigerating circuit which operates at high cooling efficiency.
This circuit takes advantage of extract air flow air to recover
part of the wasted heat. Through heat recovery it can increase both
the capacity and the nominal and seasonal efficiencies of the
unit.
KUBIC RCF Thermodynamic heatrecovery module
Free-cooling thermal or enthalpy control EC supply air plug fan
G4 gravimetric filter F6 to F9 class opacimetric filters
(in addition to G4 or Fx+Fy) Air quality sensor Dirty filters
detector Motor protection Motors for overpressure Back-up heating
coils Auxiliary heating coils Ambient temperature or wall-mounted
sensor Scheduling function and connection
* Inquire for all available options.
With MANY OPTIONAL FEATURESWith MULTIPLE CONFIGURATIONSMaximum
adaptability to existing projects
G4, F6 to F9 combinable filters
ThermostatMINI PGD
* When compared to an equivalent model from other manufacturers.
Ref. model 3002.2 with 87 kW
LESS WEIGHT
LESS HEIGHT
LESS VOLUME
-12% WEIGHT
-37% HEIGHT
-34% VOLUME
COMPACT, LIGHTWEIGHT, MODULARAND HIGHLY ENERGY EFFICIENT
A DIFFERENTROOFTOP
The units of the KUBIC series are autonomous rooftop units that
are specially designed for installation on rooftops, roof terraces
or in any other outdoor location. There are different models with
the option of cooling only or heat pump.
Its Extra-compact modular design gives a high versatility for
both installation and operation, whatever the project is. Units
will be delivered completely finished and tested, with the
appropriate load of R-410A refrigerant for their correct
operation.
Scroll type compressors
PGD Thermostat
The VRC module allows to manage different discharge air flow
renovation percentages. The assembly of three dampers also
allowsfreecooling with either thermal, enthalpy or thermo- enthalpy
management.
KUBIC VRC Module with centrifugalreturn fan
PLUGFAN FANS Greater energy efficiency Lower consumption Quieter
High pressures available Low maintenance cost
CONFIGURATION EXAMPLES
SUPPLY / RETURN SUPPLY/ NEW AIR
Any combination of supply and return is valid, taking into
account that there can only be one supply and one return.
Any combination of supply and return is valid, taking into
account that there can only be one supply and one return and one
fresh air damper.
SUPPLY / FREECOOLING
Any combination of supply and freecooling configuration is
valid, taking into account that there can only be one supply and
two dampers.
Recommended optional features
Environmentally friendly refrigerant
The module with gas burneris specially designed for the climate
control of large areas in the industrial and commercial sectors,as
well as for areas with extremely low temperatures.
KUBIC GB Module with gas burner
(Standard for RCF, VRC and GB modules)
ThermostatTH TUNE
F: fresh air damper / R: return air damper. *For specific
configurations, consult us.
Valid configurations for models up to 4502. Other
configurations, please inquire.
SUPPLY CONFIGURATIONS
Lower Upper Side
Lower Upper Left side Upper frontRight side Lower front
Lower Upper Right side Upper frontLeft side Lower front
RETURN CONFIGURATIONS
FRESH AIR DAMPER CONFIGURATIONS
FREE-COOLING CONFIGURATIONS
R
R R
R RF
FF
F
F
Lower + upper front Upper + lower front Upper + lower Front
Side
NEWMODELS
5002.4 x 6002.4 x 7002.4
COMPETITIVE ADVANTAGES• Triple return filtering.• Double circuit
with tandem compressors in order to
improve the efficiency of the equipment for partial loads
• Option for high pressure EC plug fan
• The same configuration options as the other circuits of the
range: Freecooling double dampers, VRC Module, RCF Module and GB
Module
BIG