Top Banner
3/25/14 1 Factors Affecting Coriolis Flowmeters Chris Mills, NEL Potentially ^ NEL VISCOSITY / REYNOLDS NO TEMPERATURE & PRESSURE TWO PHASE OIL & GAS CONCLUSIONS CONTENTS
15

Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

Mar 15, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

1

Factors Affecting Coriolis Flowmeters

Chris Mills, NEL!

Potentially ^

•! NEL

•! VISCOSITY / REYNOLDS NO

•! TEMPERATURE & PRESSURE

•! TWO PHASE OIL & GAS

•! CONCLUSIONS

!

CONTENTS

Page 2: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

2

NEL

Viscosity / Reynolds No

Page 3: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

3

Test Meters –!Used as research tools to identify influencing factors

Generic test meter descriptions: –!A: CORIOLIS Twin-tube ( 4" ) ; QMAX ~ 150 kg/s

Test Matrix –!5, 10, 20, ! , 90 l/s –!10, 20, 30 & 40 ºC –!Kerosene & Primol ( 2 – 300 cSt )

Coriolis Meters in Viscous Oil

Test Meter “A” (Coriolis)

-1.5

-1.0

-0.5

0.0

0.5

0 10 20 30 40 50 60 70 80

Mas

s Fl

owra

te E

rror

(%)

Reference Flowrate (kg/s)

Kerosene 10°C (3 cSt)Kerosene 20°C (2 cSt)Kerosene 30°C (2 cSt)Kerosene 40°C (2 cSt)

Coriolis Meters in Viscous Oil

Page 4: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

4

Test Meter “A” (Coriolis)

-1.5

-1.0

-0.5

0.0

0.5

0 10 20 30 40 50 60 70 80

Mas

s Fl

owra

te E

rror

(%)

Reference Flowrate (kg/s)

Kerosene 10°C (3 cSt)Kerosene 20°C (2 cSt)Kerosene 30°C (2 cSt)Kerosene 40°C (2 cSt)

Coriolis Meters in Viscous Oil

-1.5

-1.0

-0.5

0.0

0.5

0 10 20 30 40 50 60 70 80

Mas

s Fl

owra

te E

rror

(%)

Reference Flowrate (kg/s)

Primol 10°C (300 cSt)Primol 20°C (175 cSt)Primol 30°C (80 cSt)Primol 40°C (50 cSt)

Test Meter “A” (Coriolis)

Coriolis Meters in Viscous Oil

-1.50

-1.00

-0.50

0.00

0.50

100 1000 10000 100000 1000000

Mas

s Fl

owra

te E

rror

(%)

Pipe Reynolds Number

Kerosene 10°C (3 cSt)Kerosene 20°C (2 cSt)Kerosene 30°C (2 cSt)Kerosene 40°C (2 cSt)Primol 10°C (300 cSt)Primol 20°C (175 cSt)Primol 30°C (80 cSt)Primol 40°C (50 cSt)

Page 5: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

5

Test Meter “A” (Coriolis)

Coriolis Meters in Viscous Oil

-0.75

-0.50

-0.25

0.00

0.25

100 1000 10000 100000 1000000

Den

sity

Err

or (%

)

Pipe Reynolds Number

Kerosene 10°C (3 cSt)Kerosene 20°C (2 cSt)Kerosene 30°C (2 cSt)Kerosene 40°C (2 cSt)Primol 10°C (300 cSt)Primol 20°C (175 cSt)Primol 30°C (80 cSt)Primol 40°C (50 cSt)

Temperature & Pressure

Page 6: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

6

Joint Industry Project

Temperature & Pressure

Two Phase Oil & Gas

Page 7: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

7

Flow Regimes

Coriolis Two Phase Flow

Flow Regimes

Coriolis Two Phase Flow

Page 8: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

8

Coriolis Two Phase Flow

Programme: –! Assess effects of GVF on Coriolis

flowmeters –! Vertically installed –! Testing at 20 cP from 0 – 25 % GVF

(Two Phase Liquid & Gas Flow) –! Flow diagnostics

Test Meter “A” (Coriolis)

-1.00

-0.80

-0.60

-0.40

-0.20

0.00

0.20

0.40

0.60

0 5 10 15 20 25 30 35 40

Mas

s Fl

ow E

rror

, [%

]

Ref. Mass. Flow, [kg/s]

Gravi Calibration

MM Calibration

Coriolis Two Phase Flow

Page 9: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

9

Test Meter “A” (Coriolis)

-45.00

-35.00

-25.00

-15.00

-5.00

5.00

15.00

25.00

0 5 10 15 20 25 30 35 40

Mas

s Fl

ow E

rror

, [%

]

Ref. Mass. Flow, [kg/s]

< 1 % GVF

< 10 % GVF

< 25 % GVF

Coriolis Two Phase Flow

Test Meter “A” (Coriolis)

-45.00

-35.00

-25.00

-15.00

-5.00

5.00

15.00

25.00

0 5 10 15 20 25 30 35 40

Mas

s Fl

ow E

rror

, [%

]

Ref. Mass. Flow, [kg/s]

0.1 % GVF

0.2 % GVF

0.5 % GVF

1 % GVF

2 % GVF

4 % GVF

6 % GVF

8 % GVF

10 % GVF

15 % GVF

20 % GVF

25 % GVF

Coriolis Two Phase Flow

Page 10: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

10

Test Meter “A” (Coriolis)

-45.00

-35.00

-25.00

-15.00

-5.00

5.00

15.00

25.00

0 5 10 15 20 25 30 35

Mas

s Fl

ow E

rror

, [%

]

GVF, [%]

3 kg/s

5 kg/s

11 kg/s

18 kg/s

25 kg/s

35 kg/s

Coriolis Two Phase Flow

Test Meter “A” (Coriolis)

-30.00

-25.00

-20.00

-15.00

-10.00

-5.00

0.00

5.00

0 5 10 15 20 25 30

Mix

ture

Den

sity

Err

or, [

%]

GVF, [%]

3 kg/s

5 kg/s

11 kg/s

18 kg/s

25 kg/s

35 kg/s

Coriolis Two Phase Flow

Page 11: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

11

Test Meter “B” (Coriolis)

-1.00

-0.80

-0.60

-0.40

-0.20

0.00

0.20

0.40

0.60

0.80

1.00

0 5 10 15 20 25 30 35 40

Mas

s Fl

ow E

rror

, [%

]

Ref. Mass. Flow, [kg/s]

Gravi Calibration

MM Calibration

Coriolis Two Phase Flow

Test Meter “B” (Coriolis)

-25.00

-20.00

-15.00

-10.00

-5.00

0.00

5.00

10.00

15.00

20.00

25.00

0 5 10 15 20 25 30 35 40

Mas

s Fl

ow E

rror

, [%

]

Ref. Mass. Flow, [kg/s]

< 1 % GVF

< 10 % GVF

< 25 % GVF

Coriolis Two Phase Flow

Mix

ture

Den

sity

Err

or, [

%]

Page 12: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

12

Test Meter “B” (Coriolis)

-25.00

-20.00

-15.00

-10.00

-5.00

0.00

5.00

10.00

15.00

20.00

25.00

0 5 10 15 20 25 30 35 40

Mas

s Fl

ow E

rror

, [%

]

Ref. Mass. Flow, [kg/s]

0.1 % GVF

0.2 % GVF

0.5 % GVF

1 % GVF

2 % GVF

4 % GVF

6 % GVF

8 % GVF

10 % GVF

15 % GVF

20 % GVF

25 % GVF

Coriolis Two Phase Flow

Test Meter “B” (Coriolis)

-25.00

-20.00

-15.00

-10.00

-5.00

0.00

5.00

10.00

15.00

20.00

25.00

0 5 10 15 20 25 30

Mas

s Fl

ow E

rror

, [%

]

GVF, [%]

3 kg/s

5 kg/s

11 kg/s

18 kg/s

25 kg/s

35 kg/s

Coriolis Two Phase Flow

Page 13: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

13

Test Meter “B” (Coriolis)

-7.00

-6.00

-5.00

-4.00

-3.00

-2.00

-1.00

0.00

1.00

2.00

0 5 10 15 20 25 30

Mas

s Fl

ow E

rror

, [%

]

GVF, [%]

3 kg/s

5 kg/s

11 kg/s

18 kg/s

25 kg/s

35 kg/s

Coriolis Two Phase Flow

Test Meter “Z” (Coriolis)

0.00

20.00

40.00

60.00

80.00

100.00

120.00

0 5 10 15 20 25 30

[

]

GVF, [%]

3 kg/s

5 kg/s

11 kg/s

18 kg/s

25 kg/s

35 kg/s

Coriolis Two Phase Flow

Page 14: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

14

Test Meter “Z” (Coriolis)

80.00

81.00

82.00

83.00

84.00

85.00

86.00

87.00

0 5 10 15 20 25 30

Raw

Tub

e Fr

eque

ncy,

[H

z]

GVF, [%]

3 kg/s

5 kg/s

11 kg/s

18 kg/s

25 kg/s

35 kg/s

Coriolis Two Phase Flow

Test Meter “Z” (Coriolis)

80.00

81.00

82.00

83.00

84.00

85.00

86.00

87.00

0 5 10 15 20 25 30

Raw

Tub

e Fr

eque

ncy,

[H

z]

GVF, [%]

All Data

Linear (All Data)

Coriolis Two Phase Flow

Page 15: Factors Affecting Coriolis Flowmeters - VSL...Christopher Mills, Factors Affecting Coriolis Flowmeters, 2014v3.ppt Author John Lansing Created Date 20140326021934Z ...

3/25/14

15

Test Meter “Z” (Coriolis)

-60.00

-50.00

-40.00

-30.00

-20.00

-10.00

0.00

10.00

20.00

0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00

Mas

s Fl

ow E

rror

[%

]

GVF [%]

Corrected Data

Coriolis Two Phase Flow

Conclusions

Key Findings: •! Viscosity / Re No

–!Under-reading evident

–! The performance of Coriolis devices by different manufacturers are not necessarily similar.

•! Temperature & Pressure –!Confidential due to JIP

•! Oil & Gas –! Large mis-measurement evident for both mass flow

and density at low velocities