pmeasuring.com FacilityPro® Processors Data Processing and System Control Without measurement there is no control BENEFITS • Designed specifically for pharmaceutical environmental monitoring • Integration and control of viable and nonviable sampling • High data integrity • Ultimate efficiency and reduced error • Simple installation and validation • Flexible integration APPLICATIONS Monitoring of critical environments including: • Filling lines • Isolators and RABS • Blow-Fill-Seal • Lyophilizer processes and transfer carts • Biosafety cabinets and flow hoods • General cleanroom and facility monitoring Viable/Nonviable/Environmental Monitoring The FacilityPro® Processor provides the central hub for an environmental monitoring system. The Processor communicates with cleanroom sensors, including particle and microbial monitors, while buffering data and checking tolerances for alarm activation. Industrial Automation Architecture As a key component of industrial automation architecture, this embedded system offers high reliability as it controls samples and communicates with central soſtware. Three Versions FacilityPro Processors are available in three versions, with varying features to support a range of system designs and applications: • FacilityPro 5010 • FacilityPro 3000 • FacilityPro 1000 All three FacilityPro Processors are compatible with either the FacilityPro SCADA server soſtware or the FacilityPro SMART server module. The FacilityPro 1000 Processor is also suitable for OEM applications, providing an integration path between Particle Measuring Systems sensors and third-party soſtware platforms. FacilityPro 3000 FacilityPro 1000 FacilityPro 5010
8
Embed
FacilityPro® Processors - IESMAT · 2018-05-14 · FacilityPro® Processors Data Processing and System Control Display 6.5-in TFT LCD with resistive touchscreen Processor AMD Geode
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
pmeasuring.com
FacilityPro® ProcessorsData Processing and System Control
Without measurement there is no control
B E N E F I T S• Designed specifically for pharmaceutical
environmental monitoring
• Integration and control of viable and nonviable sampling
• High data integrity
• Ultimate efficiency and reduced error
• Simple installation and validation
• Flexible integration
A P P L I C AT I O N SMonitoring of critical environments including:
• Filling lines
• Isolators and RABS
• Blow-Fill-Seal
• Lyophilizer processes and transfer carts
• Biosafety cabinets and flow hoods
• General cleanroom and facility monitoring
Viable/Nonviable/Environmental Monitoring
The FacilityPro® Processor provides the central hub for an environmental monitoring system. The Processor communicates with cleanroom sensors, including particle and microbial monitors, while buffering data and checking tolerances for alarm activation.
Industrial Automation Architecture
As a key component of industrial automation architecture, this embedded system offers high reliability as it controls samples and communicates with central software.
Three Versions
FacilityPro Processors are available in three versions, with varying features to support a range of system designs and applications:
• FacilityPro 5010
• FacilityPro 3000
• FacilityPro 1000
All three FacilityPro Processors are compatible with either the FacilityPro SCADA server software or the FacilityPro SMART server module. The FacilityPro 1000 Processor is also suitable for OEM applications, providing an integration path between Particle Measuring Systems sensors and third-party software platforms.
FacilityPro 3000
FacilityPro 1000
FacilityPro 5010
FacilityPro® ProcessorsData Processing and System Control
Display 6.5-in TFT LCD with resistive touchscreen
Processor AMD Geode LX800 (500 MHz)
Dimensions (l, w, h) 13.5 x 19.0 x 8.75 in (34.3 x 48.3 x 22.3 cm), 5U height
FacilityPro 5010A fully-integrated solution for system control. Modules housed in a standard 19-inch rack.
FacilityPro® ProcessorsData Processing and System Control
Processor Intel Atom N455 (1.66 GHz)
Dimensions (l, w, h) 6.2 x 19.0 x 13.2 in (15.8 x 48.3 x 33.5 cm)
Weight 27.5 lb (12.5 kg)
Power 100 – 240 VAC, 50 – 60 Hz, 350 W
Inputs/Outputs 16 relay or digital outputs (configurable)8 digital inputs8 analog inputs, 0 – 10 VDC or 4-20mA (optional)
FacilityPro 3000A reliable data and I/O processor designed specifically for smaller systems.
Processor Intel Atom N455 (1.66 GHz)
Dimensions (l, w, h) 5.7 x 9.0 x 2.6 in (14.5 x 23.0 x 6.5 cm)
Weight 2.5 lb (1.14 kg)
Power 120 VDC, 1.5 A
Inputs/Outputs None (via ENODE® interface)
FacilityPro 1000Data processor with no built-in I/O, designed to provide a reliable Ethernet interface to viable and nonviable sensors and to upgrade existing ENODE-based systems.
FacilityPro® ProcessorsData Processing and System Control
ENODE®and FacilityPro® are registered trademarks of Particle Measuring Systems, Inc.Windows® is a registered trademark of Microsoft Corporation.
All other trademarks are the property of their respective owners.Particle Measuring Systems, Inc. reserves the right to change specifications without notice.
points per Processor 8, 16, 32 (groups of 8) 16 (8 particle, 8 microbial) 64 (groups of 8)
Digital ouputs (selectable relay or 24
VDC)- 16 up to 64 in processor
(optional I/O module)
Digital inputs - 8 up to 32 in processor (optional I/O module)
Analog inputs (optional) - 8 up to 24 in processor
(optional I/O module)
ENODE support y - -
Cubic meter algorithms y y y
Tolerance checking y y y
Recipe-driven sampling y y y
Data buffer y y y
Real-time microbial monitoring - - y
Vacuum and air flow control - - y
Microbial monitoring with central vacuum - - y
- : not supported y : supported
pmeasuring.com
FacilityPro® SoftwareData Management, Reporting, and Automation
Without measurement there is no control
B E N E F I T S• Designed specifically for pharmaceutical
environmental monitoring
• Integration and control of viable and non-viable sampling
• High data integrity
• Ultimate efficiency and reduced error
• Simple installation and validation
• Flexible integration
A P P L I C AT I O N SMonitoring of critical environments including:
• Filling lines
• Isolators and RABS
• Blow-Fill-Seal
• Lyophilizer processes and transfer carts
• Biosafety cabinets and flow hoods
• General cleanroom and facility monitoring
Viable/Nonviable/Environmental Monitoring
FacilityPro® software provides the interface, supervisory control, data management, and reporting functionality for an environmental monitoring system. FacilityPro’s ability to manage viable, nonviable, and environmental data through a common system improves the efficiency of production operations and quality investigations.
Industrial Automation Architecture
With the FacilityPro industrial automation architecture, the data processing is performed by the Processor while the data management, display, and storage are performed by the software. This design approach increases system reliability and data integrity.
Two Main Versions
FacilityPro software is available in two main versions:
• FacilityPro SCADA Server software
• FacilityPro SMART Server module
Both software platforms offer a number of intelligent features including data mapping, alarming, reporting, and recipe-driven sampling. Both also offer client software for remote access and viewing of data. The SCADA version is built on the GE® Proficy® iFIX® SCADA platform and Historian database and provides several additional advanced features.
FacilityPro® SoftwareData Management, Reporting, and Automation
FacilityPro SMART Server ModuleThe FacilityPro SMART Server is a stand-alone module that interfaces with one FacilityPro Processor per SMART module and provides a simple monitoring and reporting tool. By distributing the data processing to the FacilityPro Processor, the FacilityPro SMART server delivers high reliability and data integrity.
The FacilityPro SMART server is 21 CFR 11 compliant and provides the user with a number of tools to improve efficiency and reduce error:
• Map for visual indication of viable, nonviable, and environmental status
• Configurable display
• Alarm notification and e-signature acknowledgement
• Configurable reports including audit, statistics, and trend reports
• Batch identifiers and data filters
• Automation of sample collection, driven by recipes
• Cubic-meter algorithms for nonviable data
• Volume-based or time-based viable sampling
• Client software for remote viewing and reporting
• 12 interface languages supported
HMI Client
FacilityPro SMART Server
Server Network
Client Netw
ork (maxim
um 2 clients)
Client StationFacilityPro® Processor
Cleanroom Sensors
Alarms and I/O
Sensor Network
I/O Signals
(1 per SMART Server)
Display resolution 1280 x 1024 minimum
Minimum requirement client CPU i5 3 GHz, RAM 8 GB, HD 500.0 GB, 2 Ethernet, 1 DVD/RW, 4 USB Ports
Operating system clients Windows® 7 Ultimate – 64bit
Specifications
FacilityPro® SoftwareData Management, Reporting, and Automation
FacilityPro SCADA Server SoftwareThe FacilityPro SCADA Server software is built on GE’s Proficy iFIX SCADA platform and Historian database. The SCADA Server software supports all the same features as the SMART Server, with the addition of the following advanced features:
• Redundant server capability
• Supports multiple FacilityPro Processors
• Supports third-party PLC integration
• Supports SMS and Email-sending software package
• Supports FacilityPro WebSpace software, providing remote access to the Server through a web browser or tablet app
• iOS (iPad®) and AndroidTM app (works in conjunction with WebSpace)
FacilityPro® SoftwareData Management, Reporting, and Automation
2016.06
FacilityPro® is a registered trademark of Particle Measuring Systems, Inc.GE®, iFIX® and Proficy® are all trademarks of General Electric.
iPad is a registered trademark of Apple, Inc.iOS® is a registered trademark of Cisco.
Android™ is a trademark of Google, Inc.Windows® is a registered trademark of Microsoft Corporation.
All other trademarks are the property of their respective owners.Particle Measuring Systems, Inc. reserves the right to change specifications without notice.