Calibration Lab ILAC ( ISO / IEC 17025 ) Factory Automatic QC Inspection System According to IEC 61298 ISO 9001 OEM / ODM Service & Distributor Wanted www.eyc-tech.com MEASURING SPECIALIST eYc, Your Solution Provider | Temperature | Humidity | Pressure | | Dew Point | Flow | CO, CO 2 , PM2.5 | | Air Velocity | Signal Transmitter |
8
Embed
eYc, Your Solution Provider MEASURING SPECIALIST · Level 2 - Calibration Laboratory ILAC/TAF(ISO/IEC17025) Calibration service & Automated quality inspection system Accreditation
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
• Sensor Type : Piezoresistive diaphragm• Measuring Range : Absolute pressure:0 ... 10 bar Relative pressure:0 … 40 bar• Output : 4 … 20 mA• Signal Connection : 2-wire• Accuracy : ± 0.3 % of F.S.• Application : Instrument manufacturing / Machine devices / Water plant / Air devices
P043
• Measuring pressure for liquid• Relative Pressure : 0.1 ... 400 bar• Accuracy ( at 20 °C ± 5 °C ) : ± 0.5 % of F.S.• Housing material : SUS 316• Isolated diaphragm material : SUS 316L• Application : Process equipment / Food and Pharmaceutical Industry / Machine devices
Pressure Transmitter
P045
• -80 ... +80 ℃ / -80 ...+60 dp℃• Analog output / RS-485 ( Programmable )• Accuracy : Dew point : ± 3 dp ℃ ± ( 0.02%F.S./℃ ); Temp. : ± 0.15 ℃±0.002 ℃ x tactual Frost point, absolute humidity etc ...• Application : Industrial process / Pharmaceutical Industry
• Measuring range : 0 ... 20 m/s• Analog output• Accuracy : ± 5 % of F.S.• IP54 • Switching Analog output by dip switch• Application : Light industry process / HVAC Building / Factory
FTS14
Air Velocity Transmitter
• Measuring range : 0 ... 40 m/s• Analog output / RS-485 ( Programmable )• Accuracy : ± 2 % of F.S.• Auto-zero key, IP54 • Switch for physical quantity:[m/s]、[ft/s]...• Application : Light industry process / Pharmaceutical / Paper Industry
Air Velocity Transmitter
FTS34/35
• Measuring range : 0 ... 120 m/s Probe temperature range : 0 ... + 120 ℃ • Analog output / RS-485 ( Programmable ) • Accuracy : ± 1.5 % F.S. ; Temp. : ± 0.3 ℃ • Rugged aluminum alloy, IP65• Application : Industrial process / Chemical / Pharmaceutical / Iron and steel industry
Thermo Air Velocity Transmitter
FTM84/85
• Measuring Range : 0.1 ... 100 bar• Electric Connection : DIN43650• Accuracy : ± 0.1% of F.S.• Connection : Internal thread 1/4-18NPT• Output : 4 ... 20mA• Signal Connection : 2-wire• Application : Petrochemical industry / Chemical industry
• Input type : Thermo Differential Pressure Module• Measuring range : 0 ... 500 pa• Accuracy ( at 25 ℃ ) : ± 0.5 % of F.S.• ModBus : RS-485• Physical switch : mbar / Pa / hPa / kPa / mmH2O / mmWS / inH2O / mmHg• Square root function • Application : Monitor differential pressure of Cleanroom / Filter environment / Air duct
Average Flow Measuring Tube +Differential Pressure Transmitter
AFMT+PHM33
Hot Wire Thermal Flow Controller
FTM06
• Type : PTC thermistor• Range : Water : 0 ... 1.5 m/s : Air : 0 ... 20 m/s• Output Signal : Analog : 4 ... 20mA / 0 ... 10V ; RS-485 ; IP67• Product Accuracy : 3% < 1.5 m/s ; 3% < 20 m/s• Application : Industrial process gas supply, consumption and dry flow monitoring
AFMS-160
S-type Pitot tube
• Output : Operating pressure : Max 10 bar Operating temperature : Max. 250 °C ; Temperature tolerance : 800°C• Installation connection : 12" below 3/4" PT movable thread 18" or more is 1" PT movable thread• Length : 25 ... 1500mm / Customization• Application match : P063&SD06+DPM02 or PHM33 or PMM33+DPM02
• Type : PTC thermistor• Measuring range : Water : 1 ... 200 cm/s Oil : 3 ... 300 cm/s Gas Flow : 20 ... 2000 cm/s• Supply supply : 24 ± 10 %VDC ; IP67• Current consumption : ≤ 60 mA• Operating temperature : -40 ... 85 °C• Application : Venting systems / Hydraulic
Thermal Flow Controller
FTC04
• Sensor Type : Piezoresistive diaphragm• Measuring Range : 0 ... 20 bar• Output : 4 … 20mA• Accuracy : ± 0.5 % of F.S.• Signal Connection : 2-wire• Housing : SUS 316L• Application : Mechanical equipment / Water plant / Air equipment / Chiller unit
Differential Pressure Transmitter
P063
www.eyc-tech.com
Air velocity / Flow / Pressure / Gas
• Measuring range : 0 ... 20 m/s;0 ... 10 V• Accuracy : ± 5 % of F.S.• Economical type• Application : HVAC air process / Clean room / Laminar flow
Hot wire Air Velocity Transmitter
FTS07
Gas Monitoring Transmitter
• Input : T / H / CO / HCHO / VOC• Analog output / RS-485 ( Programmable )• Accuracy : Temp. : ± 0.3 ℃ Humidity : ± 3 % RH CO : ± 3 % of F.S. HCHO : ±5 % of F.S. VOC :±5% of F.S.• Application : Monitor parking lot / Factory Air quality
GTH53
• Input : Current / Voltage / RTD / TC Potentiometer / Linear Resistance / • Local display, Setting by key pad ( DPT02 )• Analog output / RS-485 / Relay / Frequency ( DPT02 )• Isolation : Power supply / Analog Input & Output / RS-485• Application : Distribution cabinet / Industrial facility
Signal Display MonitorSignal Converter
DPT02 / DPM02
• CO2 : 0 ... 2000 PPM• Analog output / RS-485 ( Programmable )• Accuracy : ± 40 PPM ± 3 % of reading• Non-dispersive Infrared ( NDIR )• Indoor monitor• Application : HVAC / Air conditioning / Museums / Supermarkets / Data centers / Wharehouses
• 330° turnable ; the direction of panel is changeable; good monitoring • Intput : 4 ... 20 mA • Accuracy : 0.2 % of F.S.• Electrical connection : DIN 43650 plug / M12 connector• Application : Steel Industry / Water Plants Environmental Engineering
Integrated Signal Indicator
SD05
330°210°
Air Quality LED Monitor
• Monitor PM2.5, CO2, temperature & humidity via RS-485 at the same time. • Display Type : High Brightness LED• Signal Output : RS-485 ; Protocol ; Interface : Modbus RTU ; Power : AC 230V / DC 24V, 5A• As the local situation and refer to CO2 indication standards to transfer the suitable emoticon• Refer to PMV indication to display the real-time body sensing.
DMB04
PM2.5 Air Quality Monitor
• Real-Time Data of PM2.5, CO2, temperature & humidity• Measuring Range : 0 ... 50 ℃ ; 0 ... 100 %RH ; 0 ... 2000 PPM ; 0 ... 500 μg/m³ • Accuracy : ± 0.5 ℃ ; ± 5 %RH ( 30 ... 80 %RH ) ; ± 40 PPM ± 3 % of Reading ; ± 10 μg/m³ ± 5% of Reading• Application : Indoor air quaility / HVAC / Air ventilation system / Department store
TGP03 / THP03
• Measuring media : air• Differential pressure transmitter• Average flow measuring tube length : 2 ... 40” • Operating pressure : max. 10 bar• Operating temperature : 250 ℃• Stainless steel 316• Application : Exhaust gas removal
Average Flow Measuring Tube +Differential Pressure Transmitter