June 7, 2005 ILC BDS Meeting 1 Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2 nBPM (SLAC) nBPM (KEK) FONT Compton / laserwire ODR Existing ATF Extraction Line Coupling Correction / Emittance Diagnostics
13

Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

Jan 15, 2016

Download

Documents

kasie

Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2. Coupling Correction / Emittance Diagnostics. FONT. nBPM (KEK). nBPM (SLAC). Compton / laserwire. Existing ATF Extraction Line. ODR. FF Optics Modifications. From Tauchi-san’s email ([bds 117] June 2, 2005): - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 1

Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

nBPM (SLAC)nBPM (KEK)

FONT

Compton / laserwire

ODR

Existing ATF Extraction Line

Coupling Correction /Emittance Diagnostics

Page 2: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 2

Page 3: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 3

FF Optics ModificationsFrom Tauchi-san’s email ([bds 117] June 2, 2005):

5. Optics modifications:

(1) concentrate on "optimal" design (straight) … done (2) change bends from sector bends to rectangular … done (3) use 0.8 m bends (as used in ATF) instead of 1 m for better field

stability and more space … done (4) remove octupoles (do not use them, and they are tight) … done (OC0

removed; OC1 moved away from SF1) (5) extend diagnostics section (use up to ~10 m additional space) … done (6) QM14 is the strongest quad, and is close to max field of BT quads,

need to check if its strength can be reduced by reoptimizing the matching section … done (QM14[K1L] = -1.1 m-1)

Page 4: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 4

30 cm offset

ΔL = 7.1 m (w.r.t. baseline)

β*x,y = 4,0.1 mm

Page 5: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 5

baseline

optimal

Assembly Hall

Page 6: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 6

-1% +1%

Page 7: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 7

• ideally

–correction section with 4 independent skew quadrupoles, followed by

–2D (4 wire scanner) emittance measurement section–optics for orthogonal control of the 4 coupling phases–minimize εy once with each skew quadrupole

• in present ATF extraction line

–non-optimal optics in EXT straight section–wire scanners and skew quads interspersed–each wire scanner has x, y, and “u/v” (small angle, ~10°) wires

• one attempt at full 4D beam matrix measurement and correction was inconclusive1

Coupling Correction

1 See http://atfweb.kek.jp/atf/Reports/ATF-99-01.pdf

Page 8: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 8

“Ideal” skew correction / ε diagnostic sectionSQ SQ SQ SQ

WS WS WS WS

90°90°

180°90°

90°90°

45°45°

45°45°

45°45°

– x– y

See http://www.slac.stanford.edu/cgi-wrap/getdoc/slac-pub-8581.pdf

Page 9: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 9

90°90°

180°90°

90°90°

– x– y

33°57°

57°33°

33°57°

57°33°

SQ SQ SQ SQ

WS WS WS WS WS

59.210.8

108.05.9

59.210.8

108.05.9

59.210.8σ (μm)

2.0 2.0 2.0 2.0 2.0

2.0 2.0 2.0 2.0

1.3 1.3 1.3 1.3

For MAD files see http://www.slac.stanford.edu/~mdw/ATF2/optimal

Page 10: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 10

new quadrupole (between QF3X and BH1X.3)

1 2

-1 0 0 0

-0.52 -1 0 0

0 0 -1 0

0 0 1.37 -1

K KR

Page 11: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 11

sL

w1 w2 w3

N

L 2

min02

nnc 1cot

cc 120

0

00 2

1 2

L

3n

A ‘Drift’ A ‘Drift’ -Diagnostic Section-Diagnostic Section

3 wire scanners (or profile monitors)

00 ,

20

0min

1

00 ,

from Paul Emma …

Page 12: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 12

– x– y

σmin = 3 μm

Page 13: Extended Coupling Correction and Emittance Diagnostic Section for “optimal” ATF2

June 7, 2005 ILC BDS Meeting 13

Continuing Work

• optimize system bandwidth and performance

• add BPMs and dipole correctors• simulate steering and dispersion/coupling

correction with machine/diagnostic errors• verify what space is needed for diagnostic

equipment in chicane• investigate drift ε–diagnostic section• writeup for ATF2 proposal document