www.tepex.hr TEHNICAL DATA: Certificate: CESI 08 ATEX 017X Marking: 0722 Apparatus category: II 2G, I M2 Marking of explosion protection: Ex ed IIC T2 or T3 Environment temperature: -20ºC ≤ T a ≤ +40ºC -20ºC ≤ T a ≤ +60ºC with 60W Degree of protection: IP 54 in accordance with EN 60529+A1, category 1 Resistance to shock: IK 08 in accordance with EN 50102 Insulation class : I (protective earthing) in accordance with EN 61140 Rated voltage: 250V ±10% AC 24V ±10% AC/DC Frequency: 50Hz (60Hz on request) Rated power: according to table Lamps: Incandescent lamps, E 27 lampholder, for 25W, 40W, 60W, 100W Halogen lamps, E 27 lampholder, for 100W and 150W Conecting terminals: terminals L1 + N for 2 x 4 mm ² flexible/solid terminals PE for 2 x 4 mm ² flexible/solid tightening torque for screw clamp 2,2 Nm Cable entry: 1 x M25x1.5 cable gland (through-wiring possible) 1 x M25x1.5 plug Cover fixing: M 6, Hexagonal screw; without switch DESCRIPTION: The explosion protected bulkhead light fitting of the series 0403.24/.. for incan- descent and high pressure discharge lamps meets the requirements of the ATEX -Directive 94/9/EC. The explosion protected bulkhead light fitting of the series 0403.24/.. are certified for use in mines and industry areas made hazardous by flammable gases, vapors and liquids in the zones 1, 2. The bulkhead lighting fitting, type 0403.24/.. are made with the body in aluminium alloy and the transparent part in high quality borosilicate glass, thermally treated. The Lampholder (Ex) E27 is installed in enclosure made of aluminum alloy (for II 2G) or in cast iron (for I M2). The enclosure is covered with protective glass, which is protected with steel wire guard. Sealing is achived with silicon gasket between protective glass and enclosure. Installation of lamp (on wall or ceiling) is done with two steel brackets with M6 screws. Inside the lamp an explosion protected lamp-holder E27 with different incandescent lamps are assembled. EXPLOSION PROTECTED BULKHEAD LIGHT FITTING type 0403.24 5.2