Experimental Verification of Gas-Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15, 2006 ) G. W. Woodruff School of Mechanical Engineering Atlanta, GA 30332–0405 USA
19

Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

Dec 21, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

Experimental Verification of Gas-Cooled T-Tube Divertor

Performance

L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda

ARIES Meeting, UCSD (June 14-15, 2006 )

G. W. Woodruff School ofMechanical Engineering

Atlanta, GA 30332–0405 USA

Page 2: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

2

• Design, construct, and instrument a test module which closely simulates the thermal-hydraulic behavior of the proposed helium-cooled T-Tube divertor

• Experimentally measure the axial and azimuthal variations of the local heat transfer coefficient in the test module over a wide range of operating conditions

• Perform “a priori” calculations to predict the wall temperature distribution and heat transfer coefficients for the test module using the same methodology used to analyze the actual T-Tube divertor performance

• Compare the measured heat transfer coefficients with predicted values

• Develop an experimentally-validated correlation for the local Nusselt Number for use in future design analyses of similarly-configured gas-cooled components

• Use Experimental Data to guide design modifications to enhance divertor performance

Objectives

Page 3: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

3

T-Tube Divertor Geometry• Helium Pressure = 10 MPa• Inlet Temperature = 873 K• Exit Temperature = 950 K• Flow Rate/length = 0.2 kg/s.m

25 mm

85 mm

D = 15 mm

* From T. Ihle (FZK) and R. Raffray (UCSD)

Page 4: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

4

Experimental Flow Loop• Single Inlet – Counter (or Parallel) Flow • Double Inlet

Page 5: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

5

Flow Configurations

Page 6: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

6

Inlet port

Plugged end (single inlet)

Outlet port

TC 1

TC 9

Experimental Flow Loop

Page 7: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

7

20°

20°

6.813.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 6.8

(124)

150 (Heated length) All dimensions in mm

Ø12

.70

606220

150 (Heated Length)

Ø15

.88

Inner tube: Brass0.8 mm thick

Outer tube 304 SS0.51 mm thick

0.6

Copper Electrodes

Centering teflonsectors (60°)

Centering teflonsectors (60°)

Experimental Test Section

Page 8: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

8

• Addition of two 1.2 mm wide “bridges” to preserve slit width uniformity after machining

Slit Close-up

Page 9: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

9

• Addition of three 60° Teflon ring sectors to each end of outer tube to maintain concentricity with inner tube and allow the flow to discharge

Centering the tubes

Page 10: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

10

• Experimental parameter ranges selected to match the non-dimensional parameters for the proposed helium-cooled T-Tube divertor (double inlet)

Parameter Air (low flow) Air (high flow) Helium

Operating Pressure 100 kPa 500 kPa 10 MPa

Pressure Drop 3.7 kPa 20 kPa 0.1 MPaMass Flow Rate (per unit slit length)

27 g/s.m 94 g/s.m 200 g/s.m

Inlet Temp. 20° C 20° C 600° C

Average Re 1450 5000 4800

Pr 0.71 0.71 0.66

Thermal-Hydraulic Parameters

Page 11: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

11

Model 1:

Single inlet – modeling of insulation

• FLUENT 6.2, Steady, turbulent (RNG k-) model with standard wall functions

• Grid size: 810,000 cells (single inlet); 930,000 cells (double inlet)

• One symmetry plane (single inlet)

• Two symmetry planes (double inlet)

Model 2:

Double inlet – modeling of complete test section

Predicted Performance - 3D Simulation

Page 12: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

12

• Inlet temperature: 294 k

• Max temperature: 467 k

• Power Input: 100 W

• Mass flow rate: 0.00289 Kg/s

Predicted Performance – Temperature (Double Inlet)

Page 13: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

13

• Max velocity: 93 m/s

• Operating pressure: 14.3 PSI (98 kPa)

• Pressure drop: 0.54 PSI (3700 Pa)

Predicted Performance – Flow Field (Double Inlet)

Page 14: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

14

• Max Heat Transfer Coefficient:

850 W/m2k (Standard Wall Functions)

Predicted Performance – Heat Transfer Coefficient (Double Inlet)

Page 15: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

15

Experimental Results (two inlets) Temperature & Heat Transfer Coefficient

Location 1&9

Page 16: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

16

Experimental Results (two inlets) Temperature & Heat Transfer Coefficient

Location 5

Page 17: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

17

Experimental Results – Axial variation: Effect of Flow Arrangement on Heat Transfer Coefficient

• Flow configuration has a significant effect on axial variation of heat transfer coefficient. Parallel flow arrangement is preferred

Page 18: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

18

Proposed Design Modification

Page 19: Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,

19

Summary - Path Forward

• Initial results for temperature distribution and local heat transfer coefficient show reasonably good agreement between experimental data and model predictions. Predicted temperatures are conservative.

• Flow configuration has a significant impact on axial variations of heat transfer coefficient. Temperature gradients and stress levels in the gas-cooled diveror can be controlled by proper selection of flow configuration. Parallel flow is preferred.

• Experiments will be conducted for different gas flow rates, exit pressures, power input levels, and flow configurations.

Test conditions will be selected to span the expected non-dimensional parameter ranges for the proposed helium-cooled T-Tube divertor

Data for axial and azimuthal variations of the heat transfer coefficient will be obtained for single and double inlet conditions