Page 1: Exhaustairmodule FLMS45 - DomusGaia

UHB EN 1926-1531275

USER MANUAL

Exhaust air moduleFLM S45

Page 2: Exhaustairmodule FLMS45 - DomusGaia

LEK

LEKLEK

Page 3: Exhaustairmodule FLMS45 - DomusGaia

41 Important information4Installation data

5Safety information

5Serial number

5Compatible NIBE heat pumps

62 The heating installation – the heart of the

house6Exhaust air module function

7Maintenance of FLM S45

93 Disturbances in comfort

10Item register

11Contact information

3Table of ContentsFLM S45

Table of Contents

Page 4: Exhaustairmodule FLMS45 - DomusGaia

Installation dataFLM S45Product

Serial number

Installation date

Installer

SetFact.sett.

NameNo.

XDifferential brine in-/outX

100%Exhaust air fan (fan speed, normal mode)X

Serial number must always be givenCertification that the installation is carried out according to instructions in the accompanying installer manual and applicable regulations.

__________________________________________Signed______________________________Date

FLM S45Chapter 1 | Important information4

1 Important information

Page 5: Exhaustairmodule FLMS45 - DomusGaia

Safety informationThis appliance can be used by childrenaged from 8 years and above and personswith reduced physical, sensory or mentalcapabilities or lack of experience andknowledge if they have been given super-vision or instruction concerning use of theappliance in a safe way and understandthe hazards involved. Children shall notplay with the appliance. Cleaning and usermaintenance shall not bemade by childrenwithout supervision.

Rights to make any design or technicalmodifications are reserved.

©NIBE 2019.

If the supply cable is damaged, only NIBE,its service representative or similar author-ised person may replace it to prevent anydanger and damage.

SYMBOLS

NOTEThis symbol indicates danger to person or ma-chine .

CautionThis symbol indicates important informationabout what you should observewhenmaintain-ing your installation.

Serial numberThe serial number can be found at the bottom left insidethe front cover.

LEK

CautionYou need the product's (14 digit) serial numberfor servicing and support.

Compatible NIBE heatpumpsFLM S45 ventilates the building and preheats the brine,regardless of which ground source heat pump is in-stalled, but when FLM S45 is installed together with acompatible ground source heat pump, it is possible toadjust settings and read off sensor values etc. in theheat pump’s display.

COMPATIBLE PRODUCTS

• S1255• S1155

5Chapter 1 | Important informationFLM S45

Page 6: Exhaustairmodule FLMS45 - DomusGaia

0 ºC

-3 ºC

22 ºC

-3 ºC 0 ºC

0 ºC

5 ºC-4 ºC

100 ºC

35 ºC25 ºC

Brine

RefrigerantEvaporator

Condenser

Expansion valveCompressor

1

2

Heat source

Czynnik obiegu dolnego źródła

Exhaust air modulefunctionAn exhaust air module uses the heat that is in thebuilding's ventilation air to heat up the brine.

Brine circuitAn anti-freeze liquid (brine) circulates in a hose (collector)from the heat pump out to the heat source(rock/ground/lake). The energy from the heat source isstored by it heating the brine a few degrees, from about–3 °C to about 0 °C.

A

The collector then routes the brine to the heat pump’sevaporator. Here, the brine releases heat energy and thetemperature drops a few degrees. The liquid then returnsto the heat source to retrieve energy again.

B

Refrigerant circuitAnother liquid circulates in a closed system in the heatpump, a refrigerant, which also passes the evaporator.The refrigerant has a very low boiling point. In the evapor-ator the refrigerant receives the heat energy from the brineand starts to boil.

C

The gas that is produced during boiling is routed into anelectrically powered compressor. When the gas is com-pressed, the pressure increases and the gas’s temperatureincreases considerably, from approx. 5°C to approx. 100°C.

D

From the compressor, gas is forced into a heat exchanger,condenser, where it releases heat energy to the heatingsystem in the house, whereupon the gas is cooled andcondenses to a liquid form again.

E

As the pressure is still high, the refrigerant can pass anexpansion valve, where the pressure drops so that therefrigerant returns to its original temperature. The refriger-ant has now completed a full cycle. It is routed to theevaporator again and the process is repeated.

F

Heat medium circuitThe heat energy that the refrigerant produces in the con-denser is retrieved by the climate system's water, heatingmedium, which is heated to 35 °C (supply temperature).

G

VentilationThe hot air is transferred from the rooms to the heat pumpvia the exhaust air module.

J

The fan then routes the air to the exhaust air module heatexchanger. Here, the air releases the heating energy tothe brine and the air's temperature drops significantly. Thecold air is then blown out of the house.

K

The temperatures are only examples and may vary between different installations and time of year.

FLM S45Chapter 2 | The heating installation – the heart of the house6

2 The heating installation – theheart of the house

Page 7: Exhaustairmodule FLMS45 - DomusGaia

Maintenance ofFLM S45REGULAR CHECKSYour exhaust air module requires minimal maintenanceafter commissioning. On the other hand, it is recommen-ded that you check your installation regularly.

If FLM S45 is installed with a compatible heat pump andsomething untoward occurs, a message appears regard-ing the malfunction in the form of various alarm texts inthe heat pump display.

Cleaning the ventilation devicesThe building’s ventilationdevices should be cleanedregularly with, for example,a small brush tomaintain thecorrect ventilation.

The device settings mustnot be changed.

NOTEIf you take down more than one ventilationdevice for cleaning, do not mix them up.

Cleaning the air filterClean the FLM S45's air filter regularly, how often de-pends on the amount of dust in the ventilation air. Selectwhat is most suitable for your installation.

CautionThe efficiency of the installation can be im-paired by a dirty air filter.

If FLM S45 is connected to a compatible heat pump,you receive a reminder to clean the filters in the display.The default setting for the reminder is every threemonths; however, if the power to the heat pump is in-terrupted, the countdown starts from zero again.

1. Switch off the heat pump.

2. Remove the front hatch by pulling it straight out.

3. Pull out the filter cassette.

4. Remove the filter and shake/vacuum it clean.

5. Check the condition of the filter.

6. Carry out assembly in reverse order.

Even if the filter appears clean, dirt collects in it and thisaffects the efficiency of the filter. Therefore, replace itafter 1 years. New filters can be ordered via the installer.

NOTEWater or other liquids must not be used forcleaning.

LEKLEK

Filter

7Chapter 2 | The heating installation – the heart of the houseFLM S45

Page 8: Exhaustairmodule FLMS45 - DomusGaia

Checking the condensation water seal

LEK

The condensation hose from FLMS45 has to be shapedinto a water seal. On the rear of S1255 there is a groovein the insulation for the condensation hose; other com-patible heat pumps do not have this groove.

Check that there is water in the water seal. If it is empty,or has a very lowwater level so that it “gurgles”, it mustbe topped up with water.

After a period of operation dust and other particles canclog the water seal, consequently, you should checkthis regularly and clean when necessary.

FLM S45Chapter 2 | The heating installation – the heart of the house8

Page 9: Exhaustairmodule FLMS45 - DomusGaia

In most cases, the compatible heat pump notes a mal-function (a malfunction can lead to disturbance in com-fort) and indicates this with alarms and action instruc-tions in the display.

If the malfunction does not appear in the display orFLM S45 is not connected to a compatible heat pump,the following tips can be used:

BASIC ACTIONSStart by checking the following items:

• That the heat pump is running or that the supply cableto FLM S45 is connected.

• Group and main fuses of the accommodation.

• The property's earth circuit breaker.

LOW OR A LACK OF VENTILATION• Filter blocked.

– Clean or replace filter (see page 7).

• The ventilation is not adjusted.

– Order ventilation adjustment.

• Exhaust air device blocked or throttled down toomuch.

– Check and clean the exhaust air devices (see page7).

• Fan speed in reduced mode.

– 1.2.1 and select "normal".

If FLM S45 is connected to a compatible heat pump:Enter menu 1.2.1 and select "normal".

If FLM S45 is connected to another heat pump:Contact your installer!

• External switch for changing the fan speed activated.

– Check any external switches.

HIGH OR DISTRACTING VENTILATION• Filter blocked.

– Clean or replace filter (see page 7).

• The ventilation is not adjusted.

– Order ventilation adjustment.

• Fan speed in forced mode.

– If FLM S45 is connected to a compatible heat pump:Enter menu 1.2.1 and select "normal".

If FLM S45 is connected to another heat pump:Contact your installer!

• External switch for changing the fan speed activated.

– Check any external switches.

GURGLING SOUND• Not enough water in the water seal.

– Fill the water seal with water (see page 8)

• Choked water seal.

– Check and adjust the condensation water hose (seepage 8).

9Chapter 3 | Disturbances in comfortFLM S45

3 Disturbances in comfort

Page 10: Exhaustairmodule FLMS45 - DomusGaia

C

Compatible NIBE heat pumps, 5

D

Disturbances in comfort, 9Troubleshooting, 9

G

General pipe connectionsCompatible NIBE heat pumps, 5

I

Important informationInstallation data, 4Serial number, 5

Installation data, 4

M

Maintenance of FLM S45, 7Regular checks, 7

R

Regular checks, 7

S

Serial number, 5

T

The function of the exhaust air module, 6The heating installation – the heart of the house, 6Troubleshooting, 9

FLM S45Item register10

Item register

Page 11: Exhaustairmodule FLMS45 - DomusGaia

Contact information

DENMARKCZECH REPUBLICAUSTRIA

Vølund Varmeteknik A/SIndustrivej Nord 7B, 7400 HerningTel: +45 97 17 20 [email protected]

Družstevní závody Dražice - strojírnas.r.o.Dražice 69, 29471 Benátky n. Jiz.Tel: +420 326 373 [email protected]

KNV Energietechnik GmbHGahberggasse 11, 4861 SchörflingTel: +43 (0)7662 [email protected]

GERMANYFRANCEFINLAND

NIBE Systemtechnik GmbHAm Reiherpfahl 3, 29223 CelleTel: +49 (0)5141 75 46 [email protected]

NIBE Energy Systems France SASZone industrielle RD 28Rue du Pou du Ciel, 01600 ReyrieuxTél: 04 74 00 92 [email protected]

NIBE Energy Systems OyJuurakkotie 3, 01510 VantaaTel: +358 (0)9 274 [email protected]

NORWAYNETHERLANDSGREAT BRITAIN

ABK ASBrobekkveien 80, 0582 OsloTel: (+47) 23 17 05 [email protected]

NIBE Energietechniek B.V.Energieweg 31, 4906 CGOosterhoutTel: +31 (0)168 47 77 [email protected]

NIBE Energy Systems Ltd3C Broom Business Park,Bridge Way, S41 9QG ChesterfieldTel: +44 (0)845 095 [email protected]

SWEDENRUSSIAPOLAND

NIBE Energy SystemsBox 14Hannabadsvägen 5, 285 21MarkarydTel: +46 (0)433-27 [email protected]

EVANbld. 8, Yuliusa Fuchika str.603024 Nizhny NovgorodTel: +7 831 419 57 [email protected]

NIBE-BIAWAR Sp. z o.o.Al. Jana Pawla II 57, 15-703 BialystokTel: +48 (0)85 66 28 490biawar.com.pl

SWITZERLAND

NIBE Wärmetechnik c/o ait SchweizAGIndustriepark, CH-6246 AltishofenTel. +41 (0)58 252 21 [email protected]

For countries not mentioned in this list, contact NIBE Sweden or check nibe.eu for more information.

Page 12: Exhaustairmodule FLMS45 - DomusGaia

NIBE Energy SystemsHannabadsvägen 5Box 14SE-285 21 [email protected]

UHBEN19

26-1

5312

75

This manual is a publication from NIBE Energy Systems. All product illustrations, facts anddata are based on the available information at the time of the publication’s approval.NIBE Energy Systems makes reservations for any factual or printing errors in this manual.

©2019 NIBE ENERGY SYSTEMS 531275

WS name: -GemensamtWS version: a669WS release date: 2019-06-28 07:20Publish date: 2019-08-14 11:18