Top Banner
FLUE GAS TREATMENT Latest Flue Gas Filtration technology designed for the cremation industry. www.facultatieve-technologies.com Switzerland Locarno Lugano Scotland Aberdeen Sydes Brae Warriston England Alford Barham Bath Bedford Braintee Bramcote Carlisle Coventry Durham Exeter Harrogate Hereford Lambeth (London) Maidstone Mid Warwicks Milton Keynes Mintlyn Ollerton Surrey & Sussex Three Counties Wear Valley Westerleigh West Norwood (London) Germany Dresden Frankfurt Forst Hameln Koblenz Lahr Luneburg Memmingen Neubrandenburg Schmalkalden Weissenfels Willich Italy Domodossola Isola St Michel Livorno Parma Piscina Torino Verona France Clermont-Ferrand Herlies Nice Olonne-sur-Mer Paris Ponthierry Quimper Strasbourg Wattrelos Belgium Brugge Bruxelle (Uccle) Hasselt Vilvoorde The Netherlands Assen Almelo Dieren Den Haag Emmen Enschede Geleen Heerlen Heeze Helmond Kerkrade Leiden Rotterdam Schagen Tilburg Uden Uithoorn Velsen Venlo Vlijmen Zoetermeer Sweden Falun Mora Racksta Uppsala Vaxjo Monaco Monaco Luxembourg Luxembourg Spain Barcelona FACULTATIEVE TECHNOLOGIES dedicated to the service of our clients Cremators Filter and mercury abatement systems High Speed Cremulator Ash Transfer Cabinet Specialist installation and commissioning Remote technical support Service by local Regional Engineers Design Study capabilities Examples of our European filter installations
2

Examples of our FACULTATIEVE TECHNOLOGIES · 2015-08-31 · pass directly to the waste heat boiler, where the gases are cooled as they pass through the boiler tubes. To ensure the

Jun 20, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Examples of our FACULTATIEVE TECHNOLOGIES · 2015-08-31 · pass directly to the waste heat boiler, where the gases are cooled as they pass through the boiler tubes. To ensure the

FLUE GAS TREATMENT Latest Flue Gas Filtration technology designed

for the cremation industry.

www.facultatieve-technologies.com

Switzerland

LocarnoLugano

Scotland

AberdeenSydes BraeWarriston

England

AlfordBarham

BathBedford

BrainteeBramcote

CarlisleCoventryDurham

ExeterHarrogate

HerefordLambeth (London)

MaidstoneMid WarwicksMilton Keynes

MintlynOllerton

Surrey & SussexThree Counties

Wear ValleyWesterleigh

West Norwood (London)

Germany

DresdenFrankfurt

ForstHamelnKoblenz

LahrLuneburg

MemmingenNeubrandenburg

SchmalkaldenWeissenfels

Willich

Italy

DomodossolaIsola St Michel

LivornoParmaPiscinaTorinoVerona

France

Clermont-FerrandHerlies NiceOlonne-sur-Mer ParisPonthierry QuimperStrasbourg Wattrelos

Belgium

BruggeBruxelle (Uccle)HasseltVilvoorde

The Netherlands

AssenAlmeloDierenDen HaagEmmenEnschedeGeleenHeerlenHeezeHelmondKerkradeLeidenRotterdamSchagenTilburgUdenUithoornVelsenVenloVlijmenZoetermeer

Sweden

FalunMoraRackstaUppsalaVaxjo

Monaco

Monaco

Luxembourg

Luxembourg

Spain

Barcelona

FACULTATIEVE TECHNOLOGIESdedicated to the service of our clients

✔ Cremators✔ Filter and mercury abatement systems✔ High Speed Cremulator✔ Ash Transfer Cabinet✔ Specialist installation and commissioning✔ Remote technical support ✔ Service by local Regional Engineers✔ Design Study capabilities

Examples of our European filter installations

Page 2: Examples of our FACULTATIEVE TECHNOLOGIES · 2015-08-31 · pass directly to the waste heat boiler, where the gases are cooled as they pass through the boiler tubes. To ensure the

PROCESSFlue gases evolving from the combustion of the coffin pass through the post combustion zone and pass directly to the waste heat boiler, where the gases are cooled as they pass through the boiler tubes. To ensure the highest levels of automation, the boiler is fitted with an automated tube cleaning system.

The flue gases enter the boiler at 800/850°C and exit at around 150/170 °C.

This reduction in temperature is necessary to ensure the optimal chemical reaction between the pollutant and chemical reagent “Factivate”.

The reagent is automatically injected into the system, requiring no manual intervention.

If fitted as an option, the main particles will be pre-filtered by cyclonic separation.

The pollutants are adsorbed onto the chemical additive, captured by the filter media by the formation of a filter cake.

The filter system benefits from an automated cleaning cycle, triggered by process conditions. The cleaning process typically operates at the end of each day, transferring the spent product from the filter to the storage drum.

Collected in dedicated drums, the spent reagent is then collected and transported to specialist disposal and recycling centres.

Emergency vent by-pass

FTIII cremator

Space for an additional (future)

cremator

Cyclone (optional supply)

Filtration system designed to accept

an additional (second) cremator

Flue Gas Analyser O2/CO2

(optional supply)

Filter System Control Panel

Waste Flue Gas Boiler - designed

to accept an additional (second)

cremator

Automated reagent dosing station

Spent reagent

Uniquely designed to fit the smallest of locations

FTIII cremator

SCADA Control screens

Example of a cremator installation (type FTII or FTIII cremator) and dedicated filtration system.

Filter installation

A Coffin chargerB CrematorC Analytical PanelD Automatic Process ControlE Waste Flue Gas BoilerF Air Blast CoolerG Emergency bypass damperH Preheat - filter bypass

damper

I ReagentJ Bag FilterK Spent reagentL FGT Isolation damperM ID fanN Chimney

Let us show you how you may benefit from our advice and support.

The installations of Facultatieve Technologies perform to the following:

PG5/2 (04) U.K

27.BIm.SchV Germany

Vlarem II Belgium

NeR The Netherlands

Arrêté du 29 dec 94 & new projects

France

OPAIR Switzerland

and of course with the particular standards of Sweden, Denmark, Italy, Spain, Austria, Portugal and the requirements of the OSPAR agreement for mercury abatement.

High SpeedCremulator FT IIIFT II FT USAFT I

Ash Transfer CabinetMinimaster Maximaster Model 2 Model 3 Model 4/4b Model VP500Filter