+85.300 +85.300 +85.300 +84.400 +85.300 +80.600 +85.300 +83.700 +85.300 +85.300 +85.300 +84.400 +85.300 BASEMENT OUTLINE +85.300 +84.400 +85.300 1 16 slope 1/21 slope +84.940 +84.940 Grass area 20m2 +84.828 +85.300 BOULEVARD PEDESTRIAN LINK COURT YARD BC CARPARK RAMP SOUTH PLAZA NORTH PLAZA EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM FH FH FH EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM FH EX - WM EX - WM EX - WM SV SV EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM FH EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM SV EX - WM SV SV EX - WM EX - WM EX - WM EX - WM EX - WM FH EX - WM EX - WM EX - WM EX - WM FH EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM EX - WM 6 ASBESTOS 1975 6 ASBESTOS 1975 6 ASBESTOS 1975 BB SV WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM SV SV PROPOSED OFF SITE WATERMAIN CONNECTION LOCATION TO EXISTING 14' ASBESTOS 1975 IN ACCORDANCE WITH STD-W-06 (NEW PE - CI) FROM STANDARD DETAILS WATER NETWORKS IW-CDS-5020-01 Rev. 03 ELECTRONIC BULK FLOW METER IN ACCORDANCE WITH STD-W-26 FROM STANDARD DETAILS WATER NETWORKS IW-CDS-5020-01 Rev. 03 AND SECTION 3.15.4 OF CODE OF PRACTICE (IW-CDS-5020-03) PROPOSED SLUICE VALUES FOR PE & DI PIPES IN ACCORDANCE WITH STD-W-14 & 15 FROM STANDARD DETAILS WATER NETWORKS IW-CDS-5020-01 Rev. 03 ENSURE MINIMUM PIPE SEPARATION DISTANCES IN ACCORDANCE WITH STD-W-11 FROM STANDARD DETAILS WATER NETWORKS IW-CDS-5020-01 Rev. 03 EXISTING WATERMAIN TO BE DECOMMISSIONED, SUBJECT TO DIVERSION AGREEMENT WITH IRISH WATER SV WM WM WM FH BASEMENT EXTENT (DASHED GREY) BASEMENT EXTENT (DASHED GREY) WM WM EX - WM BB SV EX - WM LEGEND: EXISTING WATERMAIN 14" " ASBESTOS 1975 EXISTING WATERMAIN TO BE DECOMISIONED PROPOSED WATERMAIN DN160mm HDPE SDR 17 PE 100 SLUICE VALVE BOUNDARY BOX THRUST BLOCK Drn by: Chkd by: Aprvd by: Code Status Revision Date: Scale: @ A1 Project: Title: Originator Zone Type Role Number Level Rev No. Date Revision Note Drn by Chkd by · FOR SETTING OUT REFER TO ARCHITECT'S DRAWINGS. · THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS AND ALL OTHER RELEVANT DRAWINGS AND SPECIFICATIONS. · DO NOT SCALE DRAWING. USE FIGURED DIMENSIONS ONLY. · NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM OR STORED IN ANY RETRIEVAL SYSTEM OF ANY NATURE WITHOUT THE WRITTEN PERMISSION OF O'CONNOR SUTTON CRONIN AS COPYRIGHT HOLDER EXCEPT AS AGREED FOR USE ON THE PROJECT FOR WHICH THE DOCUMENT WAS ORIGINALLY ISSUED. - - - Client: - - - Head Office, 9 Prussia Street, Dublin 7. D07 KT57 TEL +353 (0)1 8682000 e: [email protected] w: www.ocsc.ie Dublin London Belfast Galway Cork ENVIRONMENT QUALITY HEALTH & SAFETY ISO 14001:2015 ISO 9001:2015 OHSAS 18001:2007 NSAI Certified NSAI Certified NSAI Certified BIM Verified Design & Construction Capital/Delivery PAS 1192-2 bsi. O'CONNOR SUTTON CRONIN Multidisciplinary Consulting Engineers ORDNANCE SURVEY OF IRELAND LICENCE NO. EN0000819 © GOVERNMENT OF IRELAND Sandyford GP Limited. Sandyford Central Proposed Watermain Layout SFC OCSC 00 01 DR C 0520 A1 C02 21.02.19 NTS JB AH MOR P01 14.06.19 SUITABLE FOR INFORMATION JB AH C01 19.07.19 PAC SUBMISSION JS JB P02 05.11.2019 SUITABLE FOR REVIEW / COMMENT MK AH C02 14.11.2019 STAGE COMPLETE - PLANNING MK PR PLANNING DRAWING. NOT FOR CONSTRUCTION. ALL LEVELS GIVEN ARE RELATIVE TO ORDNANCE DATUM. THIS DRAWING HAS BEEN ISSUED FOR INFORMATION PURPOSES ONLY AND MUST NOT BE USED FOR CONSTRUCTION UNDER ANY CIRCUMSTANCES