Top Banner
EWSD Startup Version 16 Issue Date: December 2002 - Operating Documentation A30828-X1160-A-1-76A9 Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts can also have elevated operating temperatures. Non-observance of these conditions and the safety instructions can result in personal injury or in property damage. Therefore only trained and qualified personnel may install and maintain the system. The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards. Copyright (C) Siemens AG 2002 Issued by the Public Communication Network Group Hofmannstraße 51 D-81359 München Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon a written contract.
47
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ewsd v16

EWSD StartupVersion 16

Issue Date: December 2002

- Operating Documentation

A30828-X1160-A-1-76A9

Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts can also have elevated operating temperatures.Non-observance of these conditions and the safety instructions can result in personal injury or in property damage. Therefore only trained and qualifiedpersonnel may install and maintain the system. The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply withthe applicable safety standards.

Copyright (C) Siemens AG 2002

Issued by the Public Communication Network GroupHofmannstraße 51D-81359 München

Technical modifications possible.

Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon a written contract.

Page 2: ewsd v16

2

EWSDVersion 16

Operation and Maintenance

Manuals and Descriptive Material

Documents listed in Alphabetical Order

Documents listed in Numerical Order

Page 3: ewsd v16

3

Manuals and Descriptive Material

General Information

Operational Tasks

User Manual

Maintenance Tasks

Nonstandard Maintenance

Task Manual / Output Manual (TML/OML)

EMCYMN

Basic Product Information

General Information

Operational Tasks

User Manual

Maintenance Tasks

Nonstandard Maintenance

Task Manual / Output Manual (TML/OML)

EMCYMN

Basic Product Information

Return to Operation and Maintenance

Page 4: ewsd v16

4

General Information

Introduction to EWSD Documentation

Abbreviations

Safety Instructions for Personnel and Products(EN60950/IEC60950)

Construction

➪ Return to Manuals and Descriptive Material

Page 5: ewsd v16

5

Operational Tasks

Charging

Routing

Traffic

Subscriber Administration

GeoCentrex

GeoCentrex MAC

System Administration

ADMOSS

Charging

Routing

Traffic

Subscriber Administration

GeoCentrex

GeoCentrex MAC

System Administration

ADMOSS

Operational Tasks

Page 6: ewsd v16

6

Charging

Routing

Traffic

Subscriber Administration

GeoCentrex

OMN:EXCH-TA

OMN:EXCH-RO

OMN:EXCH-SS7 (SSNC)

OMN:EXCH-SS7 (CCNC)

OMN:EXCH-NT

OMN:EXCH-TR

OMN:EXCH-SU

OMN:EXCH-CTX

Page 7: ewsd v16

7

GeoCentrex MAC

System Administration

ADMOSS

Installation Manual IMN:MAC

User Manual UMN:MAC

Administration Manual ADMIN:MAC

OMN:EXCH-SY

OMN:EXCH-ADMOSS

Page 8: ewsd v16

8

User Manual

UMN:TE

UMN:TEOMN:TE-AD

OMN:TE-SUB

OMN:TE-TRK

OMN:TE - Line Test PC

MMN:TE-SUB

MMN:TE-TRK

UMN:TE

User Manual

Page 9: ewsd v16

9

Maintenance Tasks

Access

Switching Network

Control

Signaling

Software

Construction

Access

Switching Network

Control

Signaling

Software

Construction

Maintenance Tasks

Page 10: ewsd v16

10

Access

Switching Network

Control

Signaling

Software

MMN:DLU

MMN:LTG

MMN:RSU

MMN:DAS

MMN:LTGP/STMI

MMN:SN/MCH

MMN:CP

MMN:CP-Devices

MMN:CCG

MMN:MB

MMN: SS7

MMN:SW

Saving of Error Symptoms

Page 11: ewsd v16

11

Nonstandard Maintenance

Network Node

Access

Switching Network

Signaling

Control

Software

Network Node

Access

Switching Network

Control

Signaling

Software

Nonstandard Maintenance

Page 12: ewsd v16

12

Network Node

Access

Switching Network

Control

Tracer

X.25 System Administration

PCM Error Treatment / Alarm Statistics

NM:DLU

NM:LTG

NM:RSU

NM:LTGP/STMI

NM:SN/MCH

NM:CP

NM:CP-Devices

NM:CCG

NM:MB

Audits

Page 13: ewsd v16

13

Signaling

Software

NM:SS7

NM:SW

Page 14: ewsd v16

14

Task Manual / Output Manual (TML/OML)

Task Manual (TML)Output Manual (OML)

➪ Return to Manuals and Descriptive Material

Page 15: ewsd v16

15

Basic Product Information

Signaling

IN Services

OA&M

Voice Processing

Network Node

Traffic Handling

System Software

Central System Hardware

Peripheral System Hardware

Traffic Data Administration

Subscriber Features (ISDN, analog, CENTREX)

Page 16: ewsd v16

16

Signaling

• SS7

• DSS1

• QSIG

Page 17: ewsd v16

17

SS7

DSS1

QSIG

Signaling System No. 7 (SS7)

Signaling Connection Control Part (SCCP)

Transaction Capabilities Application Part (TCAP)

SS7 Signaling between DLU and LTG in the EWSD Network Node

Digital Subscriber Signaling System No. 1 (DSS1)

Signaling Protocol between Private Networks and PBX (QSIG)

Page 18: ewsd v16

18

IN Services

• Overview

• EWSD Based IN Services

• EWSD-SSP Direct AccessServices

• EWSD-SSP Services withDirect and Dial Up Access

• IN Charging

Page 19: ewsd v16

19

Overview

EWSD Based IN Services

EWSD-SSP Direct Access Services

IN Services in EWSD

Freephone

Televoting

Reverse Charging

Number Portability Service

Time Dependent Call Forwarding

Global Series Completion Service

Selective Reverse Charging

Page 20: ewsd v16

20

EWSD-SSP Services with Direct and Dial Up Access

IN Charging

Commercial Free Call Service

Automatic Service Selection

EWSD Based IN Services in Transit Network Nodes (TXS Services)

Prepaid Card Service

AMA for IN Calls on SSP

Page 21: ewsd v16

21

OA&M

• Operation

• File Transfer

• Alarming and Safeguarding

• Interfaces

• Line Maintenance

• Trunk Maintenance

Page 22: ewsd v16

22

Operation

File Transfer

Alarming and Safeguarding

Interfaces

Profiles for Subscriber Administration

NetManager Based Tariff Administration

Administration of Password Profiles

File Transfer, Access and Management (FTAM)

File Transfer Protocol (FTP)

Security in EWSD

System Alarming

X.25 Interface, OSI Layers 1 to 3

Q3 Interface, OSI Layers 4 to 7

Page 23: ewsd v16

23

Line Maintenance

Trunk Maintenance

Line Maintenance, Overview

Line Work Station

Line Test PC

Metallic Test Access A (MTAA)

Metallic Test Access B (MTAB)

Ring-back Service

Integrated Line Test Function (ILTF)

Line Lockout

Trunk Maintenance, Overview

Trunk Work Station

Test Phone

ATME 2

Page 24: ewsd v16

24

Voice Processing

Announcements

Voice Based Dialog

Applications

Individual Digital Announcement System (INDAS)

Individual Digital Announcement System (IVPS)

User Interaction LTG (UI-LTG)

Announcement prior to Dial Tone

Page 25: ewsd v16

25

Network Node

Mechanical Design

Environmental Conditions

Reliability

Synchronization

Mechanical Design of EWSD Network Nodes

Configuration Documents for EWSD Network Nodes

Environmental Conditions for EWSD Network Nodes

Reliability of EWSD

Synchronization in Communication Networks

Page 26: ewsd v16

26

Traffic Handling

• Traffic Routing

• Numbering

• Network Management

• Charging

Page 27: ewsd v16

27

Traffic Routing

Traffic Routing

Carrier Dependent Routing

Customer Dependent Routing

Automatic Alternative Routing and Automatic Rerouting

Carrier Quota

ISDN Traffic Routing Based on Transmission Quality

Privileged Traffic

Optimized Dynamic Routing (ODR)

Intercept and Cause-Value Assignment and System Behaviour

Call Divergence Destination (CDD)

Traffic Control with the Carrier Access Code

Flexible Routing via PBX Lines

Page 28: ewsd v16

28

Numbering

Network Management

Number Portability

A-Number-Dependent Traffic Routing

Multiple Local Networks in One Network Node

Second Directory Number per Subscriber or PBX

Network Management

Automatic Congestion Control (ACC)

Call Gapping

Proportional Bidding

Call Rate Reduction (Leaky Bucket)

Trunk Reservation

Mass Call Control (MCC)

Hard to Reach Control (HTRC)

Overload handling at ISDN access

Page 29: ewsd v16

29

Charging

Pulse Metering

Automatic Message Accounting with Individual Call Charge Registration

IACHASTA with Metering

IACHASTA with AMA

Hotel Billing

Determination of Tariffs and Tariff Zones

Centralized Tariffing in Deregulated Networks

Customer Individual Charging

Subscriber Credit Limit Supervision

Meter Observation with Immediate Printout

Meter Observation

Preventive Meter Observation

Charge Data Security

Detailed Billing

Saving and Transfer of Charge Data by the SSNC

Hot Billing

Page 30: ewsd v16

30

System Software

Software Principles

Software Management

Database

Recovery, Concept and Levels

Overload Control

Page 31: ewsd v16

31

Central System Hardware

• CCNC/SSNC

• CP

• MB

• CCG

• SN

Page 32: ewsd v16

32

CCNC/SSNC

Common Channel Signaling Network Control (CCNC)

SSNC - Overview

SSNC - Software

SSNC - Hardware

SSNC - Global Title Translation (GTT)

SSNC - Multiple SS7 Networks

SSNC - High-Speed Signaling Links (HSL)

SSNC - MTP Route Verification Test (MRVT)

SSNC - SS7 Screening

SSNC - SS7 Accounting

SSNC - Multiple OPC

SSNC - Number Portability (NP) Server

SSNC - MTP Loadsharing

SSNC - Direct Linkset for Secondary OPC

SSNC - Clock Interfaces

Page 33: ewsd v16

33

CP

MB

CCG

SN

Coordination Processor 113D (CP113D)

Coordination Processor 113C/CR (CP113C/CR)

Coordination Processor 113E (CP113E)

Message Buffer B (MBB)

Message Buffer D (MBD)

Central Clock Generator A (CCGA) and Clock Distribution

Central Clock Generator, Type E (CCGE)

Switching Network (SN)

Switching Network B (SNB)

Switching Network D (SND)

Page 34: ewsd v16

34

Peripheral System Hardware

• DLU

• LTG

• RSU

Page 35: ewsd v16

35

DLU

Digital Line Unit (DLU)

Digital Line Unit B (DLUB)

Digital Line Unit D (DLUD)

Digital Line Unit V (DLUV)

Digital Line Unit G (DLUG)

Remote Control Unit (RCU)

V5.1 Interface at DLU

Overview Remote Shelter

Overview Remote Shelter DLU 400/700/1000

Overview Remote Shelter DLU 150

Remote Digital Line Unit in to Shelter (RSDLU)

Page 36: ewsd v16

36

LTG

RSU

Line/Trunk Groups (LTG) - Overview

Line/Trunk Group (LTG) - Software

Line/Trunk Group B (LTGB)

Line/Trunk Group C (LTGC)

Line/Trunk Group D (LTGD)

Line/Trunk Group F (LTGF)

Line/Trunk Group G (LTGG)

Line/Trunk Group H (LTGH)

Line/Trunk Group M (LTGM)

Line/Trunk Group N (LTGN)

Line/Trunk Group P (LTGP)

V5.2 Interface at LTG

Digital Echo Compensation

Remote Switching Unit (RSU) - Overview

Remote Switching Unit (RSU) - Functions

Page 37: ewsd v16

37

Traffic Data Administration

• Overview

• Traffic Measurement

• Traffic Monitoring

• Traffic Observation

• Traffic Structure Measurement

Page 38: ewsd v16

38

Overview

Traffic Measurement

Traffic Monitoring

Traffic Observation

Traffic Data Administration, Overview

Traffic Measurement

Traffic Monitoring

TCAP Monitoring for Network Nodes with SSNC

SCCP/TCAP Monitoring for Network Nodes with CCNC

Subscriber Observation

Page 39: ewsd v16

39

Traffic Structure Measurement

Traffic Structure Measurement

SS7 Traffic Structure Measurement for Network Nodes with CCNC

SS7 Traffic Structure Measurement for Network Nodes with SSNC

Page 40: ewsd v16

40

Subscriber Features (ISDN, analog, CENTREX)

Overview

Subscriber Features for Incoming Calls

Subscriber Features for Outgoing Calls

Display Features

Hunting Group Features / PBX Features

Conference Features / Multi-Party-Features

Charging Features

Special Subscriber Features / Operator Features

Group Features

Attendant Features

Page 41: ewsd v16

41

Overview

Subscriber Features for Incoming Calls

ISDN Analog CTX Title

X Overview ISDN

X Overview GeoCENTREX

X X X Feature Interactions

ISDN Analog CTX Title

X X X Call Waiting (CW)

X X X Selective Call Waiting (SCW)

X X X Call Forwarding Controlled by Operator (CFCO)

X X X Selective Call Forwarding (SCF)

X X X Call Forwarding to an Operator (CFO)

X X X Call Forwarding to a Voice Mail Service (CF-VMS)

X X X Call Forwarding to Any Number (CFAN)

X X X Call Forwarding to a Fixed Announcement (CFFA)

X X X Call Forwarding to a Group of Announcements (CFGA)

X Series Completion Service (SCS)

X X Call Deflection (CD)

X X X Rejection of Forwarded Calls (RFC)

X X X Selective Call Rejection (SCR)

Page 42: ewsd v16

42

Subscriber Features for Outgoing Calls

X X X Selective Call Acceptance (SCA)

X X X Kick out

X X Call Waiting Deluxe (CWD)

X X X Multiple Simultaneous Call Forwarding (MSCF)

X X X Parallel Ringing (PRNG)

X X X Do not Disturb (DND)

X X X Distinctive Ringing (DR)

X X X Selective Ringing (SR)

X X X Subaddressing (SUBA)

ISDN Analog CTX Title

X Originating Restrictions (OR)

X X Automatic Recall (AR)

X X X Selective Call Originating (SCO)

X X X Abbreviated Dialing (ABBD)

X X X Emergency Call Service (ECS)

X X X Call Completion to Busy Subscriber (CCBS)

ISDN Analog CTX Title

Page 43: ewsd v16

43

Display Features

X X X Call Completion on No Reply (CCNR)

X X X Fixed Destination Call (FDC)

X X X Call Barring

ISDN Analog CTX Title

X X X Anonymous Call Rejection (ACR)

X X Calling Name Identification Presentation (CNIP)

X X Test Data Message (TDM)

X X Calling Line Identification Presentation on Call Waiting (CLIPCW)

X X Connected Line Identification Presentation (COLP)

X X X Connected Line Identification Restriction (COLR)

X X X Calling Line Identification Presentation (CLIP)

X X X Calling Line Identification Restriction (CLIR)

X Called Line Identification Restriction (CALR)

ISDN Analog CTX Title

Page 44: ewsd v16

44

Hunting Group Features / PBX Features

Conference Features / Multi-Party-Features

ISDN Analog CTX Title

X Partial Rerouting (PR)

X Call Forwarding in Case of all Lines Disturbed (CFALD)

X X X Extension individual Call Forwarding of PBX

X Connection of ISDN PBX to two Local Network Nodes

X X X Direct Dialing-In (DDI)

X X X Line Hunting (LH)

X X X Overflow between PBXs of a PBX Group

ISDN Analog CTX Title

X X X Three-party Conference (TPC)

X X X Explicit Call Transfer (ECT)

X X X Large Conference (LC)

X X X Telemeeting

X X Call Hold (CH)

Page 45: ewsd v16

45

Charging Features

Special Subscriber Features / Operator Features

ISDN Analog CTX Title

X Account Code

X Automatic Announcement of Charges (AAOC)

X X X Advice of Charge (AOC)

X Subscriber Charge Indication

X X X No Charge Calls (NCC)

X X X Reverse Charging at Setup Time (RCST)

X X Coinbox Telephone Service

X X X Reverse Charge Call Rejection (RCCR)

ISDN Analog CTX Title

X X X General Facility Reset (GFR)

X X User-to-User Signaling (UUS)

X Subscriber Barge-in (SBI)

X X Trunk Offering/No Trunk Offering

X X X Malicious Call Recording (MCR)

X X X Automatic Feature Subscription (AFS)

X X X Automatic Turn-on (ATO)

X X X Remote Subscriber Controlled Input (RSCI)

Page 46: ewsd v16

46

X X X Closed User Group (CUG)

X X X Malicious Call Identification (MCI)

X X X Immediate Call Identification (ICI)

X X X Nailed-up Connection (NUC)

X Manager Secretary Team Function

X X Multiple Subscriber Number (MSN)

X Multiple Subscriber Number (MSN) with Different Ringing

X X X Multilevel Precedence and Preemption

X X X Personal Identification Number (PIN)

X X Voice Data Protection (VDP)

X X X Access Barring

X X X Feature Control Offline

X X X Priority (PRIO)

X Teleworking

X X Terminal Portability (TP)

X X X Preference Category During Catastrophe

X X X Alarm Call Service (ACS)

ISDN Analog CTX Title

Page 47: ewsd v16

47

Group Features

Attendant Features

ISDN Analog CTX Title

X Terminating Restrictions (TR)

X Call Pick Up (CPU)

X Night Service Call Pick Up (NSCPU)

X Group Features

X Subscriber Call Park

X Central Dial In

ISDN Analog CTX Title

X Attendant Group Features