Top Banner
1 November 2007 DFI Helical Foundations and Tie-Backs Seminar Evidence of Seismic Resistance of Helical Foundations Howard A. Perko, Ph.D., P.E. Magnum Piering, Inc. November 2007 DFI Helical Foundations and Tie-Backs Seminar Outline IBC Seismic Loads Seismic Case Studies Seismic Damping of Helical Piles Example Seismic Design
20

Evidence of Seismic Resistance of Helical Foundations

Dec 03, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Evidence of Seismic Resistance of Helical Foundations

1

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Evidence of Seismic Resistance of Helical

Foundations

Howard A. Perko, Ph.D., P.E.Magnum Piering, Inc.

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Outline

• IBC Seismic Loads• Seismic Case Studies• Seismic Damping of Helical Piles• Example Seismic Design

Page 2: Evidence of Seismic Resistance of Helical Foundations

2

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Earthquake Loads (IBC 2006)

• Design to Resist Earthquake Loads– Exceptions:

• One and Two-Family Dwellings in Seismic Design Categories A, B, or C where mapped short-period response < 0.4 g

• Wood Frame Buildings in Accordance with Section 2308• Agricultural Storage Structures

– Seismic Design Category• Based on Occupancy and Severity of Ground Motion

– Site Class• Classification based on Soils Present

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Seismic Design of Piers or Piles (IBC 2006)

• Seismic Design Category C– Interconnect Piles or Pile Caps with Ties

• Capable of Tension or Compression Force, Fs

Fs = 0.1 x Pc x SDS

Pc = Higher Column Load– Connection of Piles to Pile Cap

• Provide Transverse Steel as Required for Column• Provide Tension Connection

– Pile Splices• Develop Full Tensile Strength of Pile, or• Designed to Resist Seismic Load Combinations

Page 3: Evidence of Seismic Resistance of Helical Foundations

3

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Seismic Design of Piers or Piles (IBC 2006)

• Seismic Design Category D, E, or F– Meet Requirements of Seismic Design Category C– Design Details for Piles

• Designed to Withstand Maximum Imposed Ground Motions– Lateral Resistance to Structure Seismic Forces– Liquefiable Strata

– Connection of Piles to Pile Cap• Design Tension Connection for lesser of

– 1.3 x Mechanical Tensile Capacity of Pile– 1.3 x Pullout Capacity of Pile– Seismic Load Combinations

• Design Moment Connection for lesser of– Mechanical Axial, Shear, and Moment Capacity of Pile– Seismic Load Combinations

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Earthquake Loads (IBC 2006)

• Vertical Component, EV– EV = 0.25 SDS D where,

• SDS = Short Period Design Acceleration• D = Dead Load

• Horizontal Component, EH– EH = ρ QE where,

• ρ = Redundancy Factor (1 to 1.5)• QE = Horizontal Seismic Forces (CS W “Base Shear”)• CS = Seismic Response Coefficient (I SDS/R “Simplified”• W = Weight of Structure (Dead + Select Live Loads• R = Response Modification Coefficient (1.5 to 8)

Page 4: Evidence of Seismic Resistance of Helical Foundations

4

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Seismic Design Category (2006 IBC)

Seismic Design Category E:

Occupancy I, II, or III

with SD1 ≥ 0.75

Seismic Design Category F:

Occupancy IV

with SD1 ≥ 0.75

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Occupancy Category (IBC 2006)

• I : Agricultural and Storage Facilities• II: Other Structures• III: High Occupancy Structures• IV: Essential Facilities

Page 5: Evidence of Seismic Resistance of Helical Foundations

5

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Earthquake Loads (IBC 2006)

• Adjusted Maximum Acceleration– SMS = Fa Ss

• Design Acceleration– SDS = 2/3 SMS

November 2007DFI Helical Foundations and

Tie-Backs Seminar

0.2 s Acceleration, Ss (2006 IBC)

Page 6: Evidence of Seismic Resistance of Helical Foundations

6

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Site Coefficients (2006 IBC)

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Site Class Definitions (2006 IBC)

Page 7: Evidence of Seismic Resistance of Helical Foundations

7

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Residence, Northridge, CA

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Shopping Mall, Northridge, CA

Page 8: Evidence of Seismic Resistance of Helical Foundations

8

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Common Pile Failures

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Page 9: Evidence of Seismic Resistance of Helical Foundations

9

November 2007DFI Helical Foundations and

Tie-Backs Seminar

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Damping

0

5

10

15

20

25

30

35

0 1 2 3 4 5 6

Frequency (Hz)

Cap

Dis

plac

emen

t Am

plitu

de (m

m) Measured

Computed, Damping Ratio=0%

Computed, Damping Ratio=20%

Page 10: Evidence of Seismic Resistance of Helical Foundations

10

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Damping

• Pile Head Accelerations can be Reduced by 60% due to Damping

(Tabesh and Poulos, 1999)

November 2007DFI Helical Foundations and

Tie-Backs Seminar

0.2 s Acceleration, Ss (2006 IBC)

Gatlinburg, TN

Seismic Parameters:

SS = 0.50

Page 11: Evidence of Seismic Resistance of Helical Foundations

11

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Site Class Definitions (2006 IBC)Seismic Parameters:

SS = 0.50Site Class = D

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Site Coefficients (2006 IBC)Seismic Parameters:

SS = 0.50Site Class = DFa = 1.4

Page 12: Evidence of Seismic Resistance of Helical Foundations

12

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Earthquake Loads (IBC 2006)

• Adjusted Maximum Acceleration– SMS = Fa Ss

• Design Acceleration– SDS = 2/3 SMS

Seismic Parameters:

SS = 0.50Site Class = DFa = 1.4

– SMS = 1.4 (0.5) = 0.7

– SDS = 2/3 (0.7) = 0.47

SDS = 0.47

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Occupancy Category (IBC 2006)

• I : Agricultural and Storage Facilities• II: Other Structures• III: High Occupancy Structures• IV: Essential Facilities

Seismic Parameters:

SS = 0.50Site Class = DFa = 1.4SDS = 0.47Occup. = III

Page 13: Evidence of Seismic Resistance of Helical Foundations

13

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Seismic Design Category (2006 IBC)Seismic Parameters:

SS = 0.50Site Class = DFa = 1.4SDS = 0.47Occup. = IIIS.D.C. = C

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Seismic Design of Piers or Piles (IBC 2006)

• Seismic Design Category C– Interconnect Piles or Pile Caps with Ties

• Capable of Tension or Compression Force, Fs

Fs = 0.1 x Pc x SDS

Pc = Higher Column Load– Connection of Piles to Pile Cap

• Provide Transverse Steel as Required for Column• Provide Tension Connection

– Pile Splices• Develop Full Tensile Strength of Pile, or• Designed to Resist Seismic Load Combinations

Seismic Parameters:

SS = 0.50Site Class = DFa = 1.4SDS = 0.47Occup. = IIIS.D.C. = C = 0.1(50)(0.47) = 2.4 kips

= 50 kipsFS = 2.4 kips

Page 14: Evidence of Seismic Resistance of Helical Foundations

14

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Earthquake Loads (IBC 2006)

• Vertical Component, EV– EV = 0.25 SDS D where,

• SDS = Short Period Design Acceleration

• D = Dead Load

Seismic Parameters:

SS = 0.50Site Class = DFa = 1.4SDS = 0.47Occup. = IIIS.D.C. = C

– EV = 0.25 (0.47) (50 kips)– EV = 5.9 kips

FS = 2.4 kipsEV = 5.9 kips

November 2007DFI Helical Foundations and

Tie-Backs Seminar

What About Damping?

– Re-do Example with 60% Damping

Page 15: Evidence of Seismic Resistance of Helical Foundations

15

November 2007DFI Helical Foundations and

Tie-Backs Seminar

0.2 s Acceleration, Ss (2006 IBC)

Gatlinburg, TN

Seismic Parameters:

SS = 0.32

SS = 0.50 @5% Damping

Thus, SS = 0.32 @60% Damping

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Site Class Definitions (2006 IBC)Seismic Parameters:

SS = 0.32Site Class = D

Page 16: Evidence of Seismic Resistance of Helical Foundations

16

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Site Coefficients (2006 IBC)Seismic Parameters:

SS = 0.32Site Class = DFa = 1.5

SS=0.32

1.5

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Earthquake Loads (IBC 2006)

• Adjusted Maximum Acceleration– SMS = Fa Ss

• Design Acceleration– SDS = 2/3 SMS

Seismic Parameters:

SS = 0.32Site Class = DFa = 1.5

– SMS = 1.5 (0.32) = 0.48

– SDS = 2/3 (0.48) = 0.32

SDS = 0.32

Page 17: Evidence of Seismic Resistance of Helical Foundations

17

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Occupancy Category (IBC 2006)

• I : Agricultural and Storage Facilities• II: Other Structures• III: High Occupancy Structures• IV: Essential Facilities

Seismic Parameters:

SS = 0.32Site Class = DFa = 1.5SDS = 0.32Occup. = III

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Seismic Design Category (2006 IBC)Seismic Parameters:

SS = 0.32Site Class = DFa = 1.5SDS = 0.32Occup. = IIIS.D.C. = B

Page 18: Evidence of Seismic Resistance of Helical Foundations

18

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Seismic Design of Piers or Piles (IBC 2006)

• Seismic Design Category A&B– No Special Seismic Requirements

Seismic Parameters:

SS = 0.32Site Class = DFa = 1.5SDS = 0.32Occup. = IIIS.D.C. = BFS = na

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Earthquake Loads (IBC 2006)

• Vertical Component, EV– EV = 0.25 SDS D where,

• SDS = Short Period Design Acceleration

• D = Dead Load

Seismic Parameters:

SS = 0.32Site Class = DFa = 1.5SDS = 0.32Occup. = IIIS.D.C. = B

– EV = 0.25 (0.32) (50 kips)– Ev = 4.0 kips

FS = naEV = 4.0 kips

Page 19: Evidence of Seismic Resistance of Helical Foundations

19

November 2007DFI Helical Foundations and

Tie-Backs Seminar

ComparisonWith 60% Damping:

SS = 0.32Site Class = DFa = 1.5SDS = 0.32Occup. = IIIS.D.C. = BFS = naEV = 4.0 kips

With 5% Damping:

SS = 0.50Site Class = D

Fa = 1.4SDS = 0.47

Occup. = IIIS.D.C. = C

FS = 2.4 kipsEV = 5.9 kips

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Conclusions

• Historical Use of Helical Piles Suggests Excellent Earthquake Resistance

• More Research is Needed into Helical Pile Seismic Damping

• The Future of Helical Piles may be for Seismic Retrofit or New Foundations in Earthquake Prone Areas

Page 20: Evidence of Seismic Resistance of Helical Foundations

20

November 2007DFI Helical Foundations and

Tie-Backs Seminar

Conclusions…. hurry, before our Gatlinburg house looks like this…..

…. or this!