Top Banner
J. E. “Jay” McDonald, II M.D. McDonald Eye Associates Fayetteville, Arkansas www.mcdonaldeye.com Financial disclosure: Bausch and Lomb – Consultant; Addition Technology - Advisory Board; Santen - Research Support; Acufocus - Research Support; Alcon Pharmacology - Speaker Bureau; Wave Tec – Research Support; Inspire – Consultant; Revitalvision, Inc. - Advisory Board
11

Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

Jan 06, 2016

Download

Documents

Robert Mendoza

J. E. “Jay” McDonald, II M.D. McDonald Eye Associates Fayetteville, Arkansas www.mcdonaldeye.com. Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

J. E. “Jay” McDonald, II M.D.

McDonald Eye Associates

Fayetteville, Arkansas

www.mcdonaldeye.com

Financial disclosure: Bausch and Lomb – Consultant; Addition Technology - Advisory Board; Santen - Research Support; Acufocus - Research Support; Alcon Pharmacology - Speaker Bureau; Wave Tec – Research Support; Inspire – Consultant; Revitalvision, Inc. - Advisory Board

Page 2: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

Coaxial Microincision Cataract Surgery Coaxial Microincision Cataract Surgery (MICS)(MICS)

The trend in cataract surgery is toward smaller incisions

Coaxial MICS (C-MICS)Use current phaco techniqueReduce surgically induced astigmatism (SIA)1-3

Increase wound sealability4 Reduce endothelial cell loss5

1.Heg Wee Jin. WOC 2008, Hong Kong. 2.Braga-Mele R. ASCRS in San Francisco, CA, April, 2009.3.Barrett GD. APAO Congress. Bali, Indonesia, May, 2009.4.Barrett GD, Carlsson A. Canadian Ophthalmological Society, Montreal, Canada, June, 2007. 5.Zafirakis P. ASCRS in San Francisco, CA, April, 2009.

Page 3: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

Complete MICS SystemComplete MICS System

Stellaris system for 1.8 mm phaco Akreos MICS IOL implantable through

1.8 mm incision

Page 4: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

Stellaris 1.8 Coaxial MICS Only system designed for coaxial 1.8 mm

microincision cataract surgery (C-MICS) Easy transition from small-incision to

microincision surgery StableChamber fluidics enhances

followability, holdability and chamber stability

1.8 mm C-MICS(22 gauge)

2.8 mm SICS(19 gauge)

Page 5: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

5

Akreos MICS IOLAkreos MICS IOL

Akreos MICS lens inserts through 1.8 mm phaco incision30% thinner than

Akreos AO lens Aspheric aberration-free

optic Moderate refractive index 360° posterior square-edge design

Page 6: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

StudyStudy Retrospective chart review All procedures by same surgeon in same OR Millenium small incision cataract surgery (SICS)

2.8 mm (n=45) Eyes implanted with SofPort AO or Crystalens IOL

Stellaris 1.8 mm MICS (n=63) Eyes implanted with Akreos MICS IOL

EPT, cataract density assessed perioperatively Flare/cells assessed 3.5-5.0 hours postop

Trace=0.5, 1=1.0, 1+-1.5, 2=2.0, 2+=2.5 Uncorrected and best-corrected distance visual

acuity at 3 and 6 months Some eyes targeted for monovision; measured

uncorrected and best-corrected near VA at 3 and 6 months

Page 7: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

ResultsResults

SICS MICS P-value

Cataract Density

2.12 2.150.7745

EPT 3.9 4 0.7851

Cells/Flare 1.78 1.26 0.0001

Page 8: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

Mean Distance Visual Mean Distance Visual AcuityAcuity

3M UCVA

3M BCVA

6M UCVA

6M BCVA

2.8 mm SICS

20/34 20/25 20/26 20/24

1.8 mm MICS

20/27 20/21 20/25 20/21

Page 9: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

3 Month Distance Visual Acuity3 Month Distance Visual Acuity

Page 10: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

6 Month Distance Visual Acuity6 Month Distance Visual Acuity

Page 11: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

Conclusion Microincision cataract surgery results in

a quieter postoperative eye than small incision cataract surgery

Minimizing incision size in cataract surgery may also:Decrease surgically induced astigmatismImproves wound strength and integrityReduces endothelial cell lossReduce postoperative endophthalmitisReduce patient recovery time