Top Banner
ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 Support and Maintenance Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 Copyright Fujitsu Technology Solutions, Release August 2011 0
45

ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Jul 11, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

ETERNUSDX80 S2, DX90 S2,DX410 S2 and DX440 S2

Support and Maintenance

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 Copyright Fujitsu Technology Solutions, Release August 20110

Page 2: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Content

Maintenance Utilities Maintenance Operations Log and Dump Management System Utilities for User "root" System Utilities for User "f.ce"

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 Copyright Fujitsu Technology Solutions, Release August 20111

Page 3: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Maintenance Utilities

Overview Screens / Device Status Screens Preventive Maintenance Force Disable / Force Enable Locator LED Hot Spare Definition RAID Group Administration / RAID Group Recovering Volume Administration

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 Copyright Fujitsu Technology Solutions, Release August 20112

Page 4: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Overview ScreenThis screen appears directly after login to the ETERNUS

DX S2 systems Status of the hardware components General system information Global information about RAID Group, Thin Provisioning and

Snap Data Pool

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 3

Page 5: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

System InformationTop menu Component Shows details and status information of the ETERNUS DX Selected objects listed under the column "Category" show information

for the following components• Controller Enclosure and its CMs and CAs• Drive Enclosure and its IOMs• Disks

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 4

Page 6: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Enclosures and Disks OverviewFollowing tasks are available in the Action column Preventive Maintenance Force Disable, Force Enable Remove Disk Drive

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 5

Page 7: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Preventive MaintenanceDetach and replace active components showing early signs of

a failure

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 6

Page 8: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Force DisableDisable components forcibly A degraded sense information is notified and sent to the server

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 7

Page 9: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Force EnableForcibly enable a component that was earlier removed from

the system

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 8

Page 10: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Locator LEDControls the Identify LEDs on the Operator Panel and on the

CM of the Controller Enclosure "turn on" (blinking) or "turn off"

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 9

Page 11: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Hot Spare DefinitionAssign or Release Global Hot Spare Disks Defined for all RAID Groups of the entire ETERNUS DX S2 system

Assign or Release Dedicated Hot Spare Disks Defined for one selected RAID Group only

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 10

Page 12: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

RAID Group Administration Create a new RAID GroupExpand a RAID GroupCheck the RAID consistency and perform data verificationCreate Volumes

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 11

Page 13: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

RAID Group Recovering RAID Group can be recovered by executing one of the

following functionalities Force recovery (Data is recovered)

• Data reliability can be verified after the ETERNUS DX recovers from an error status , for example from a Machine Down status

Recovering by Disk maintenance (Data is not recovered)

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 12

Page 14: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Volume Administration "Category" provides the performance administration of

volumes "Action" provides all administration tasks for a selected Volume

or Group of Volumes Including the administration of the Thin Provisioning Volumes and Snap

Data Volumes

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 13

Page 15: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Maintenance Operations

Start / End Maintenance Add Drive Enclosure Exchange CM Memory DX80 S2 / DX90 S2 Add CM Memory DX400 S2 Add Channel Adapter Remove Disk Drive

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 Copyright Fujitsu Technology Solutions, Release August 201114

Page 16: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Start / End MaintenanceThis function must be enabled for operations like

"Preventive Maintenance", "Force Disable" and "Force Enable" Selecting "Start/End Maintenance" suppresses/releases all system error

messages The maintenance status appears at the upper right corner of the window

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 15

Page 17: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Add Drive EnclosureAdd Drive Enclosure without shutting down the ETERNUS DX

system An instruction wizard will guide through the installation

• Click icon "Component" select the appropriate DX system in the column "Category" and in the column "Action" click the icon "Add Drive Enclosure"

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 16

Page 18: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Exchange CM Memory DX80 S2 / DX90 S2 Change cache memory without stopping operation Dual CM configuration with CM overlapping Multipath is a pre-requisite Maximum one DIMM per CM

• 2 GB for DX80 S2 and 4 GB for DX90 S2

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 17

Page 19: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Add CM Memory DX400 S2Add additional memory capacity without stopping operation A wizard guides you through the procedure CM overlapping Multipath is a pre-requisite ETERNUS DX400 S2 systems allow a cache configuration with mixed

DIMM sizes

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 18

Page 20: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Add Channel AdapterAdd Channel Adapters without stopping operation Dual CM configuration with CM overlapping Multipath is a pre-requisite

CAs with the same adapter topology type are fitted in pairs Different CA topologies are supported within the same ETERNUS DX S2

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 19

Page 21: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Remove Disk DriveAlways use the ETERNUS Web GUI or CLI to remove an

inventoried disk drive First the target disk must be removed from any RAID or Hot Spare

configuration This feature permanently removes the disk from the configuration Disk drives must be removed one at a time

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 20

Page 22: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Log and Dump Management

Error Statistics - IOM6 Error Statistics - Disks System Event Dump Event Log / Export Log Export Panic Dump Export G-List

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 Copyright Fujitsu Technology Solutions, Release August 201121

Page 23: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Error Statistics - IOM6Error statistics of the IOM6 For example error counts that occurred at the backend SAS path For the CM and CA modules there are no error statistics available

• Performance Information is available

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 22

Page 24: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Error Statistics - DisksTracking of disk error conditions To clear disk error information, tick the check box of the disk and select

"Clear Error" in the right "Action" column Selecting "Clear All Error" clears all disk error information

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 23

Page 25: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

System Event DumpAdministration of the Event NotificationDisplay and delete Event log informationExport and delete LogExport CM Panic Dumps and Disk G-Lists

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 24

Page 26: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Event LogEvent history information such as volume creation or module

failure Entries are stored in a ring buffer with maximum of 400 log entries

• Up to 400 last events "Delete" button clears the log

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 25

Page 27: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Export LogExport or delete internal logs Segment size of the exported file and the time range of logs can be

specified By clicking the "Delete" button all internal logs can be deleted

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 26

Page 28: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Export Panic DumpExport (save) CM Panic Dumps Each CM can reserve up to two Panic Dumps

• If two or more CM failures occur, the newest and the oldest Panic Dumps are kept

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 27

Page 29: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Export G-ListExport (save) information of G-List (Growth-List) and Non-

medium Error Counts that are recorded in the disk management area of each disk

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 28

Page 30: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

System Utilities for the User "root"

Shutdown/Restart System Export ETERNUS Configuration Backup ETERNUS Configuration

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 Copyright Fujitsu Technology Solutions, Release August 201129

Page 31: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

System Utilities for the User "root"Shutdown and Restart of the ETERNUS DX systemBackup ConfigurationExport Configuration

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 30

Page 32: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Shutdown/Restart SystemShutdown or reboot Normally these tasks are rarely necessary because all hardware

activities can be done online

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 31

Page 33: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Export ConfigurationSave the ETERNUS DX configuration information in an

external user-specified folder The configuration information is saved in binary format It is recommended to export the ETERNUS DX configuration before and

after the configuration is changed This saved data file can be used to recover a critical problem later

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 32

Page 34: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Backup ConfigurationSave the configuration settings Up to four configurations can be saved and later applied to the

ETERNUS DX S2 system It is recommended to save the configuration every time the configuration

is changed

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 33

Page 35: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

System Utilities for the User "f.ce"

Apply Configuration Initialize BUD Clear Sense Data Recovery Utilities Diagnosis Disk Drives

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 Copyright Fujitsu Technology Solutions, Release August 201134

Page 36: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Apply ConfigurationThe default user account "f.ce" can apply a selected

configuration setting One of the last three configurations One of the four backup generations An exported configuration file

Two methods to apply: "Restore" and "Initialize"

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 35

Page 37: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Initialize BUDAll firmware archives, internal logs and Panic Dumps of the

ETERNUS DX S2 are deletedCurrently active firmware needs to be re-registered after the

initialization

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 36

Page 38: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Clear Sense DataDelete all statistical information and sense data It is a recommendation to delete this information after maintenance tasks This prevents the ETERNUS DX from sending out unnecessary error

reports

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 37

Page 39: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Recovery Utilities (1)Reset Backup and Restore Fail Recovery starts depending on the ETERNUS DX system status

• Status "Backup Fail" occurs on an ETERNUS DX system that cannot start up because an error occurred during a power failure or while turning off

• Status "Restore Fail" occurs on an ETERNUS DX system that cannot start up because an error occurred while turning power on

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 38

Page 40: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Recovery Utilities (2)Force write back Forcibly write back all user data that are left in the cache of the CM

• Use this function when data in the cache could not be automatically written back to the disks

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 39

Page 41: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Recovery Utilities (3)Force Restore Forcibly restore cached user data that was backed up from the cache to

the BUD during a mains power failure• If for example the ETERNUS DX has status "Not Ready", the user data on BUD

will not be restored automatically to the cache when mains power is restored

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 40

Page 42: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Recovery Utilities (4)Reset Machine Down Recovery Fail Saving cached data when both CMs are simultaneously offline

• Clears the internal ETERNUS DX status "Machine Down" To finish off recycle the power

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 41

Page 43: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Recovery Utilities (5)Reboot All CMs Do not use this function unless a specific instruction is given by the back

level support• This is a function to reboot all CMs in order to recover from Machine Down• Reboot will be performed in 30 seconds after executing this command

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 42

Page 44: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active

Copyright Fujitsu Technology Solutions, Release August 2011

Diagnosis Disk DriveDiagnosis of selected disks This feature can be used after capacity expansion with new disks Running the diagnostics has an impact on the internal performance and it

can take a long time to complete

Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 43

Page 45: ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · 2011-09-22 · Initialize BUD All firmware archives, internal logs and Panic Dumps of the ETERNUS DX S2 are deleted Currently active