Top Banner
Nokia Siemens Networks GSM/EDGE BSS, rel. RG10(BSS), operating documentation, issue 03 Connector Panels and External Cables in Flexi BSC and TCSM3i DN70617303 Issue 1-0
111
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ET

Nokia Siemens Networks GSM/EDGE BSS, rel. RG10(BSS), operating documentation, issue 03

Connector Panels and External Cables in Flexi BSC and TCSM3i

DN70617303

Issue 1-0

Page 2: ET

2 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804bce7d

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2009. All rights reserved

f Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures.

Non-observance of these conditions and the safety instructions can result in personal injury or in property damage.

Therefore, only trained and qualified personnel may install and maintain the system.

The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.

The same text in German:

Wichtiger Hinweis zur Produktsicherheit

In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.

Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-zungen und Sachschäden führen.

Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet.

Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.

Page 3: ET

DN70617303Issue 1-0

3

Connector Panels and External Cables in Flexi BSC and TCSM3i

Id:0900d805804bce7d

Table of ContentsThis document has 111 pages.

Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.1 Use of product names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.2 Connector panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.3 Related information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.4 Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2 Connector panel types in the Flexi BSC . . . . . . . . . . . . . . . . . . . . . . . . 12

3 E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H) . . . 143.1 Connector panels CPETS-G and CPETS-H with RJ45 connectors. . . . 143.2 Flexi BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163.2.1 Optional cabling cabinet is not used . . . . . . . . . . . . . . . . . . . . . . . . . . . 163.2.2 Optional cabling cabinet is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183.3 TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343.3.1 TCSM3i for stand-alone installation option . . . . . . . . . . . . . . . . . . . . . . 343.3.2 TCSM3i for combined BSC/TCSM installation option . . . . . . . . . . . . . . 39

4 E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F) . 404.1 Connector panels CPETS-E and CPETS-F with RJ45 connectors . . . . 404.2 Flexi BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414.2.1 Optional cabling cabinet is not used . . . . . . . . . . . . . . . . . . . . . . . . . . . 424.2.2 Optional cabling cabinet is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444.3 TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 594.3.1 TCSM3i for stand-alone installation option . . . . . . . . . . . . . . . . . . . . . . 604.3.2 TCSM3i for combined BSC/TCSM installation option . . . . . . . . . . . . . . 65

5 E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F). . 665.1 Connector panels CPETC-E and CPETC-F with D37 connector packs 665.2 Flexi BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 675.2.1 Optional cabling cabinet is not used . . . . . . . . . . . . . . . . . . . . . . . . . . . 685.2.2 Optional cabling cabinet is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 695.3 TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 845.3.1 TCSM3i for stand-alone installation option . . . . . . . . . . . . . . . . . . . . . . 845.3.2 TCSM3i for combined BSC/TCSM installation option . . . . . . . . . . . . . . 90

6 Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

6.1 LAN interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 916.1.1 1 Gbit/s optical uplink LAN cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 926.1.2 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cables . . . . . . . . . . . . . . . . 926.2 External alarm cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 956.3 VDU/LPT peripheral cabling (LPT/VDU interfaces) . . . . . . . . . . . . . . . 1016.4 External synchronisation cabling (EXT SYNC interfaces) . . . . . . . . . . 103

7 Cabling panel with grounding outlets (CPGO) . . . . . . . . . . . . . . . . . . . 105

Page 4: ET

4 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804bce7d

8 Requirement specifications for external cables of M98 mechanics Flexi BSC and TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

8.1 General requirements for connectors and cable materials . . . . . . . . . . 1068.2 Requirements for specified coaxial cable assemblies . . . . . . . . . . . . . 1068.2.1 E1 coaxial unbalanced PCM cable assembly . . . . . . . . . . . . . . . . . . . . 1068.2.2 Unbalanced (coaxial) external synchronisation cable assembly (CKB) 1068.3 Requirements for specified twisted pair cable assemblies . . . . . . . . . . 1078.3.1 10 Base-T /100 Base-TX / 1000Base-T/TX LAN cable assemblies (CNI and

cross-connected LAN cable). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1078.3.2 T1 (E1) balanced PCM cable assembly (CNIS) . . . . . . . . . . . . . . . . . . 1078.3.3 E1 balanced PCM cable assembly (CNIB) . . . . . . . . . . . . . . . . . . . . . . 1078.3.4 E1 balanced PCM cable assembly (CNIA) . . . . . . . . . . . . . . . . . . . . . . 1078.3.5 Current and voltage-controlled alarm cable assembly (CNDC) . . . . . . 1088.3.6 Alarm cable (CNDE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1088.3.7 Alarm cable (CYV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1088.3.8 Alarm cable (CYR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1088.3.9 Electrical performance requirements for X.25 cable assemblies . . . . . 1088.3.10 Electrical performance requirements for optical LC cable assemblies (mul-

timode cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1098.3.11 Electrical performance requirements for optical LC cable assemblies (sin-

glemode cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

Page 5: ET

DN70617303Issue 1-0

5

Connector Panels and External Cables in Flexi BSC and TCSM3i

Id:0900d805804bce7d

List of FiguresFigure 1 Connector panel CPETS-G and CPSM cable (front view). . . . . . . . . . . 15Figure 2 Connector panel CPETS-H (front view) . . . . . . . . . . . . . . . . . . . . . . . . . 16Figure 3 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 17Figure 4 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 19Figure 5 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 35Figure 6 Connector panel CPETS-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Figure 7 Connector panel CPETS-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Figure 8 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables. . . 43Figure 9 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 43Figure 10 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables. . . 45Figure 11 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 46Figure 12 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables. . . 61Figure 13 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 61Figure 14 CPETC-E panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Figure 15 CPETC-F panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Figure 16 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 68Figure 17 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 70Figure 18 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 85Figure 19 D-connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87Figure 20 Panel CPRJ45-A with LAN, alarm, LPT/VDU, and synchronisation interfac-

es - seen from the front of the cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . 91Figure 21 Optical LC connectors, straight type . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Figure 22 Installation of the EXAU-A; mounting on the wall, cabling, and setting the

buzzer jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100Figure 23 Peripheral cables; CNM for VDU and CNP for LPT. . . . . . . . . . . . . . . 102Figure 24 CPGO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105Figure 25 Optical LC connectors, straight type . . . . . . . . . . . . . . . . . . . . . . . . . . 105

Page 6: ET

6 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804bce7d

List of TablesTable 1 BSC network elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Table 2 TCSM3i product family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Table 3 Connector panels and the CPGO used in the Flexi BSC . . . . . . . . . . . . 12Table 4 E1 trunk cable connector, pin configuration . . . . . . . . . . . . . . . . . . . . . . 17Table 5 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 17Table 6 Balanced panel at the BSCC cabinet top in first deliveries . . . . . . . . . . 18Table 7 Balanced panel at the BSCC cabinet top in upgrade deliveries . . . . . . 18Table 8 Balanced connector panels for the BSC3i . . . . . . . . . . . . . . . . . . . . . . . 19Table 9 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 19Table 10 Balanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Table 11 Balanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . . . 27Table 12 Balanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . . . 35Table 13 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 35Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface . .

36Table 15 CPETS-H balanced panels in the TCSM3i cabling cabinet - Ater-interface

38Table 16 E1 and T1 trunk cable connector, pin configuration . . . . . . . . . . . . . . . . 42Table 17 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 42Table 18 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 43Table 19 Balanced panel at the BSCC cabinet top in first deliveries . . . . . . . . . . 44Table 20 Balanced panel at the BSCC cabinet top in upgrade deliveries . . . . . . 44Table 21 Balanced connector panels in the cabling cabinet . . . . . . . . . . . . . . . . . 45Table 22 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 45Table 23 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 46Table 24 Balanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Table 25 Balanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . . . 52Table 26 Balanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . . . 60Table 27 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 60Table 28 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 61Table 29 Balanced panels in the cabling cabinet - A-interface . . . . . . . . . . . . . . . 62Table 30 Balanced panels in the cabling cabinet - Ater-interface . . . . . . . . . . . . . 65Table 31 Unbalanced panel at the BSCC cabinet top in first deliveries . . . . . . . . 68Table 32 Unbalanced panel at the BSCC cabinet top in upgrade deliveries . . . . 69Table 33 Unbalanced connector panels for the Flexi BSC . . . . . . . . . . . . . . . . . . 69Table 34 Recommended cable type for E1 coaxial trunk cables (CPRD) . . . . . . 70Table 35 Unbalanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Table 36 Unbalanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . 76Table 37 Unbalanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . 85Table 38 Recommended cable type for E1 coaxial trunk cables (CPRD) . . . . . . 85Table 39 Unbalanced panels in cabling cabinet - A-interface . . . . . . . . . . . . . . . . 87Table 40 Unbalanced panels in cabling cabinet - Ater-interface . . . . . . . . . . . . . . 90Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-

nected cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Table 42 CNIX cable connector, pin configuration in 1 Gbit/s use (cross-connected

cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Page 7: ET

DN70617303Issue 1-0

7

Connector Panels and External Cables in Flexi BSC and TCSM3i

Id:0900d805804bce7d

Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-nected cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Table 44 CNI cable connector, pin configuration in 1 Gbit/s use (straight-connected cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

Table 45 Recommended cable types for LAN cables (CNI and CNIX) . . . . . . . . 94Table 46 External alarm cabling connectors in the CPRJ45-A panel . . . . . . . . . 95Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable

with D25 connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Table 48 Signals on panel connector 21 (Voltage and current-controlled AL inputs,

AEIx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97Table 49 Signals on panel connector 23 (current-controlled ALS inputs) . . . . . . 98Table 50 General requirements for external alarm cable CNDE . . . . . . . . . . . . . 99Table 51 V.24/V.11 cable connector in the CPRJ45-A panel, pin configuration 101Table 52 Recommended cable types for V.24/V.11 cables (CNI) . . . . . . . . . . . 102Table 53 The pin configuration for connectors 18 and 19 . . . . . . . . . . . . . . . . . 103Table 54 Recommended cable types for synchronisation cables (CNI) . . . . . . 103Table 55 Pin configuration for connectors 20 and 28 . . . . . . . . . . . . . . . . . . . . 104Table 56 Main characteristics of optical singlemode cables and connectors . . 105Table 57 Main characteristics of optical multimode cables and connectors . . . 105

Page 8: ET

8 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804bce7d

Page 9: ET

DN70617303Issue 1-0

9

Connector Panels and External Cables in Flexi BSC and TCSM3i

Summary of changes

Id:0900d805804dcc03

Summary of changesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.

Issue 1-0The first issue of Connector Panels and External Cables in Flexi BSC and TCSM3i, based on Connector Panels and External Cables in BSC3i and TCSM3i. It is included in Flexi BSC first delivery and upgrade delivery documentation and in TCSM3i delivery documentation.

Page 10: ET

10 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d3524

Overview

1 OverviewThis is a description of the connector panels and the related external cables used in the first-delivery Flexi BSC and in the upgrade-delivery Flexi BSC and in the TCSM3i.

The cabling connecting the equipment to the environment is treated from the point of view of the Flexi BSC and TCSM3i, indicating how and where the external wiring is con-nected to.

1.1 Use of product namesAcronyms related to Flexi BSC are presented in the following tables.

Acronyms related to TCSM3i are presented in the following table.

1.2 Connector panelsThe following connector panels and their external cabling are discussed in this docu-ment:

BSC = Base Station Controller, a general term for all BSC network elements

General name Product name Explanation

BSCi/BSC2i BSCi High capacity (upgraded) version of the first generation DX 200 BSC (BSCE)

BSC2i High capacity version of the second gener-ation DX 200 BSC2

Flexi BSC product family

BSC3i 660 660 TRX one cabinet configuration, upgradable to Flexi BSC

BSC3i 1000/2000 1000 TRX one-cabinet or 2000 TRX two-cabinet configuration, upgradable to Flexi BSC

Flexi BSC 3000 TRX one-cabinet configuration (S14)

Table 1 BSC network elements

TCSM3i high capacity transcoder submultiplexer, TCSM3i

Installation option Product name Explanation

TCSM3i for stand-alone installation option

TCSM3i high capacity transcoder submultiplexer, American National Standards Institute (ANSI) version of TCSM3i

ET interfaces in ANSI environment

TCSM3i for stand-alone installation option

TCSM3i high capacity transcoder submultiplexer, European Telecom-munications Standards Institute (ETSI) version of TCSM3i

ET interfaces in ETSI environment

TCSM3i for combined BSC/TCSM installation option

TCSM3i for combined BSC/TCSM installation option

STM-1/OC-3 inter-faces in the A-inter-face

Table 2 TCSM3i product family

Page 11: ET

DN70617303Issue 1-0

11

Connector Panels and External Cables in Flexi BSC and TCSM3i

Overview

Id:0900d805804d3524

• CPETS-G and CPETS-H (E1 balanced) • CPETS-E and CPETS-F (E1/T1 balanced) • CPETC-E and CPETC-F (unbalanced) • CPRJ45-A • CPGO

This document also contains Requirement specification for external cables of Flexi BSC equipment.

1.3 Related informationFor information on power distribution, site requirements, cabling and dimensioning prin-ciples of the Flexi BSC, see Installation Site Requirements for Flexi BSC product Family and TCSM3i, Engineering for Flexi BSC, and Engineering for TCSM3i.

1.4 FeedbackWe are always interested to know whether our manuals provide the information you need. If you have any comments about this document or any other manual, please pass them on to your local sales representative.

Page 12: ET

12 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d0c7c

Connector panel types in the Flexi BSC

2 Connector panel types in the Flexi BSCThe site (outgoing external) cables enter the network element system through the con-nector panels. Most of the cables are terminated at the connector panels mounted in the cabling cabinet or at the equipment cabinet top (small CPETx, CPRJ45-A). Only the external STM-1/OC-3 trunk cabling and GigE Ethernet interface cabling is routed through the grounding outlets (CPGO).

The panels are connected by internal cabling through the cartridge back plane to the rear connectors of the Exchange Terminal plug-in unit ET16 (E1, T1, JT1), Clock and Tone Generator unit CL3TG-UA and the Hardware Alarm Terminal HWAT-B/-A or straight to the front connectors of SDH/SONET Exchange Terminal ETS2 and the LAN Switch plug-in units ESB24-A/ESB26.

The small CPETx panels used at the BSCC cabinet top are optional and ordered sepa-rately. The small and the large CPETx panels used in the optional cabling cabinet are delivered with the cabinet. Three cabling cabinet options are available:

• Cabling cabinet 2 PCMs / cable (connector panels CPETS-G and CPETS-H) • Cabling cabinet 1 PCM / cable (connector panels CPETS-E and CPETS-F) • Cabling cabinet coaxial PCMs (connector panels CPETC-E and CPETC-F)

Note that in Flexi BSC first deliveries, there is an additional small CPETx connector panel at the cabling cabinet top.

The panels mounted in the cabling cabinets are listed in the table below.

Panel type

Panel Connectors Description

CPETS-G 48 x E1

C111221

24 x RJ45, balanced, 2 x E1/RJ45

For balanced E1 trunk cables. Two external PCM lines are coupled to each RJ45 plug, which are terminated to the rear connectors of the ET16 Exchange Terminal plug-in units. Capacity 48 PCMs.

CPETS-E 48 x E1, T1, JT1

C109821

48 x RJ45, balanced For balanced E1, T1 or JT1 trunk cables. One external PCM line is coupled to each RJ45 plug, which are terminated to the rear connectors of the ET16 Exchange Terminal plug-in units. Capacity 48 PCMs.

CPETC-E 48 x E1

C109824

12 x 8 D-connector block unbalanced - coaxial 2 x SMD/E1

For unbalanced coaxial E1 trunk cables. One external PCM line is coupled to each pair of (Tx, Rx) SMD plugs, which are terminated to the rear connec-tors of the ET16 Exchange Terminal plug-in units. Capacity 48 PCMs.

Table 3 Connector panels and the CPGO used in the Flexi BSC

Page 13: ET

DN70617303Issue 1-0

13

Connector Panels and External Cables in Flexi BSC and TCSM3i

Connector panel types in the Flexi BSC

Id:0900d805804d0c7c

The external cables are connected to the connector panels; therefore, extra grounding devices are not needed.

CPETS-H 256 x E1

C111222

128 x RJ45, balanced, 2 x E1/RJ45

For balanced E1 trunk cables. Two external PCM lines are coupled to each RJ45 plug, which are terminated to the rear connectors of the ET16 Exchange Terminal plug-in units. Capacity 256 PCMs.

CPETS-F 256 x E1, T1, JT1

C109822

256 x RJ45, balanced For balanced E1, T1 or JT1 trunk cables. One external PCM line is coupled to each RJ45 plug, which are terminated to the rear connectors of the ET16 Exchange Terminal plug-in units. Capacity 256 PCMs.

CPETC-F 256 x E1

C109823

64 x 8 D-connector block unbalanced - coaxial 2 x SMD/E1

For unbalanced coaxial E1 trunk cables. One external PCM line is coupled to each pair of (Tx, Rx) SMD plugs, which are terminated to the rear connec-tors of the ET16 Exchange Terminal plug-in units. Capacity 256 PCMs.

CPRJ45-A 109825 16 x RJ45

2 x BNC

2 x D25

1 x D9

8 x LC

Interfaces for 100 Mbit/s and 1 Gbit/s LAN uplinks, LPTs and VDUs, incoming external syn-chronisation signals, and inputs and outputs for external alarms.

CPGO C104594

External STM-1/OC-3 trunk cables and GigE Ethernet inter-face cables

Panel type

Panel Connectors Description

Table 3 Connector panels and the CPGO used in the Flexi BSC (Cont.)

Page 14: ET

14 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

3 E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

3.1 Connector panels CPETS-G and CPETS-H with RJ45 con-nectorsThe small CPETx connector panel (CPETS-G) and the large CPETx connector panel (CPETS-H) are used for reducing site cabling as two external PCM lines are connected from each RJ45 connector. The panels fulfil E1 requirements. They can also be used for T1 interface if ANSI-specific line protection is not required.

The cabling of the CPETS-G panels is described in the cabling lists delivered in the Site Documents binder. The CPETS-G is installed at the BSCC cabinet top (one panel) or in the optional cabling cabinet (a total of four small panels, because there are three small panels in the cabinet and an additional small panel at the cabling cabinet top in first deliveries). The installation of the connector panel at the equipment cabinet top requires the use of Roof adapter (RACP) and the installation of the connector panel at the cabling cabinet top in first deliveries requires the use of Roof adapter 2 (RACP2).

For details of the panel, see figure Connector panel CPETS-G and CPSM cable (front view).

Page 15: ET

DN70617303Issue 1-0

15

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

Figure 1 Connector panel CPETS-G and CPSM cable (front view)

The cabling of the CPETS-H panels is described in the cabling lists delivered in the Site Documents binder. The CPETS-H is installed in the optional cabling cabinet (two panels).

For details of the panel, see figure Connector panel CPETS-H (front view).

CPETS-G

Front view

Rear view

0

LINEALARMS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

ET16

CPSM

DN70457779

00

02

04

06

08

10

01

03

05

07

09

11

00

01

08

09

16

17

24

25

32

33

40

41

02

03

10

11

18

19

26

27

34

35

42

43

04

05

12

13

20

21

28

29

36

37

44

45

06

07

14

15

22

23

30

31

38

39

46

47

Page 16: ET

16 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

Figure 2 Connector panel CPETS-H (front view)

3.2 Flexi BSCDepending on the maximum number ET interfaces, the Flexi BSCi can be used either with or without a cabling cabinet.

3.2.1 Optional cabling cabinet is not usedThe optional cabling cabinet is not needed, if the number ET interfaces needed does not exceed 48.

00

01

08

09

16

17

24

25

32

33

40

41

02

03

10

11

18

19

26

27

34

35

42

43

04

05

12

13

20

21

28

29

36

37

44

45

06

07

14

15

22

23

30

31

38

39

46

4748

49

56

57

64

65

72

73

80

81

88

89

50

51

58

59

66

67

74

75

82

83

90

91

52

53

60

61

68

69

76

77

84

85

92

93

54

55

62

63

70

71

78

79

86

87

94

9596

97

104

105

112

113

120

121

128

129

136

137

98

99

106

107

114

115

122

123

130

131

138

139

100

101

108

109

116

117

124

125

132

133

140

141

102

103

110

111

118

119

126

127

134

135

142

143144

145

152

153

160

161

168

169

176

177

184

185

146

147

154

155

162

163

170

171

178

179

186

187

148

149

156

157

164

165

172

173

180

181

188

189

150

151

158

159

166

167

174

175

182

183

190

191192

193

200

201

208

209

216

217

194

195

202

203

210

211

218

219

196

197

204

205

212

213

220

221

198

199

206

207

214

215

222

223

224

225

232

233

240

241

248

249

226

227

234

235

242

243

250

251

228

229

236

237

244

245

252

253

230

231

238

239

246

247

254

255

CPETS-H

DN70458754

Page 17: ET

DN70617303Issue 1-0

17

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

The E1 trunk cable connector and configuration is presented in the following table.

Recommended cable type for E1 trunk cables (CNIB) for the CPETS-G and CPETS-H is presented in the following table and figure.

Figure 3 RJ45 connector cable (CNIB cable type) with four connectors

The external trunk cable (from the ET panel) and the connector should meet the require-ments of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connector should also meet the requirements of the FCC Part 68.

The following table shows the equipping order of the CPETS-G panel at the cabinet top in first deliveries.

Pin Signal Colour Remarks

1 R White/Blue Incoming direction # 1

2 T Blue

3 R White/Green Incoming direction # 2

4 R White/Orange Outgoing direction # 1

5 T Orange

6 T Green Incoming direction # 2

7 R White/Brown Outgoing direction # 2

8 T Brown

Table 4 E1 trunk cable connector, pin configuration

Cable type: 4x(4x2xAWG26/1) 120 Ω , insulated pairs, twisted, double-shielded, cross section 0.4 mm2

Cable connector: RJ45 modular connector plug (8-pole)

Table 5 Recommended cable type for E1 trunk cables (CNIB)

CONNECTOR

DN00206525

1 2 3 4

Page 18: ET

18 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

The following table shows the equipping order of the CPETS-G panel at the cabinet top in upgrade deliveries.

3.2.2 Optional cabling cabinet is usedThe cabling cabinet must be used, if more than 48 ET interfaces are needed.

ETC car-tridge

From SGC1C-A connector position

To CPETS-G connector position

Front ports in CPETS-G panel thorough this cable

Corresponding external ET numbers

ETC 0 B 19.1A B 00 00,01,02,03 ET368,ET369,ET370,ET371

ETC 0 B 19.1J B 01 04,05,06,07 ET372,ET373,ET374,ET375

ETC 0 B 19.1R B 02 08,09,10,11 ET376,ET377,ET378,ET379

ETC 0 B 19.1Z B 03 12,13,14,15 ET380,ET381,ET382,ET383

ETC 0 B 20.1A B 04 16,17,18,19 ET256,ET257,ET258,ET259

ETC 0 B 20.1J B 05 20,21,22,23 ET260,ET261,ET262,ET263

ETC 0 B 20.1R B 06 24,25,26,27 ET264,ET265,ET266,ET267

ETC 0 B 20.1Z B 07 28,29,30,31 ET268,ET269,ET270,ET271

ETC 0 B 21.1A B 08 32,33,34,35 ET272,ET273,ET274,ET275

ETC 0 B 21.1J B 09 36,37,38,39 ET276,ET277,ET278,ET279

ETC 0 B 21.1R B 10 40,41,42,43 ET280,ET281,ET282,ET283

ETC 0 B 21.1Z B 11 44,45,46,47 ET284,ET285,ET286,ET287

Table 6 Balanced panel at the BSCC cabinet top in first deliveries

ETC car-tridge

From GT6C-A connector position

To CPETS-G connector position

Front ports in CPETS-G panel through this cable

Corresponding external ET numbers

ETC 0 B 01.1A B 00 00,01,02,03 ET512,ET513,ET514,ET515

ETC 0 B 01.1J B 01 04,05,06,07 ET516,ET517,ET518,ET519

ETC 0 B 01.1R B 02 08,09,10,11 ET520,ET521,ET522,ET523

ETC 0 B 01.1Z B 03 12,13,14,15 ET524,ET525,ET526,ET527

ETC 0 B 02.1A B 04 16,17,18,19 ET528,ET529,ET530,ET531

ETC 0 B 02.1J B 05 20,21,22,23 ET532,ET533,ET534,ET535

ETC 0 B 02.1R B 06 24,25,26,27 ET536,ET537,ET538,ET539

ETC 0 B 02.1Z B 07 28,29,30,31 ET540,ET541,ET542,ET543

ETC 0 B 03.1A B 08 32,33,34,35 ET544,ET545,ET546,ET547

ETC 0 B 03.1J B 09 36,37,38,39 ET548,ET549,ET550,ET551

ETC 0 B 03.1R B 10 40,41,42,43 ET552,ET553,ET554,ET555

ETC 0 B 03.1Z B 11 44,45,46,47 ET556,ET557,ET558,ET559

Table 7 Balanced panel at the BSCC cabinet top in upgrade deliveries

Page 19: ET

DN70617303Issue 1-0

19

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)The following table shows the connector panels in the cabling cabinet.

The cables and the connectors should meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the requirements of the FCC Part 68.

Recommended cable type for E1 trunk cables (CNIB) is presented in the following table and figure.

Figure 4 RJ45 connector cable (CNIB cable type) with four connectors

Equipping orderThe equipping order of the connector panels in the cabling cabinet in first deliveries is presented in the following table.

Panel number

Connector panel

T00 CPETS-G

0 CPETS-H

1 CPETS-G

2 CPETS-G

3 CPETS-G

4 CPETS-H

Table 8 Balanced connector panels for the BSC3i

Cable type: 4x(4x2xAWG26/1) 120 Ω , insulated pairs, twisted, double-shielded, cross section 0.4 mm2

Cable connector: RJ45 modular connector plug (8-pole)

Table 9 Recommended cable type for E1 trunk cables (CNIB)

CONNECTOR

DN00206525

1 2 3 4

Page 20: ET

20 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

ETC 0 B 22.1A Panel 00 / B 00 00,01,02,03 ET256,ET257,ET258,ET259

ETC 0 B 22.1J Panel 00 / B 01 04,05,06,07 ET260,ET261,ET262,ET263

ETC 0 B 22.1R Panel 00 / B 02 08,09,10,11 ET264,ET265,ET266,ET267

ETC 0 B 22.1Z Panel 00 / B 03 12,13,14,15 ET268,ET269,ET270,ET271

ETC 0 B 23.1A Panel 00 / B 04 16,17,18,19 ET304,ET305,ET306,ET307

ETC 0 B 23.1J Panel 00 / B 05 20,21,22,23 ET308,ET309,ET310,ET311

ETC 0 B 23.1R Panel 00 / B 06 24,25,26,27 ET312,ET313,ET314,ET315

ETC 0 B 23.1Z Panel 00 / B 07 28,29,30,31 ET316,ET317,ET318,ET319

ETC 0 B 24.1A Panel 00 / B 08 32,33,34,35 ET320,ET321,ET322,ET323

ETC 0 B 24.1J Panel 00 / B 09 36,37,38,39 ET324,ET325,ET326,ET327

ETC 0 B 24.1R Panel 00 / B 10 40,41,42,43 ET328,ET329,ET330,ET331

ETC 0 B 24.1Z Panel 00 / B 11 44,45,46,47 ET332,ET333,ET334,ET335

ETC 0 B 25.1A Panel 00 / B 12 48,49,50,51 ET336,ET337,ET338,ET339

ETC 0 B 25.1J Panel 00 / B 13 52,53,54,55 ET340,ET341,ET342,ET343

ETC 0 B 25.1R Panel 00 / B 14 56,57,58,59 ET344,ET345,ET346,ET347

ETC 0 B 25.1Z Panel 00 / B 15 60,61,62,63 ET348,ET349,ET350,ET351

ETC 0 B 26.1A Panel 00 / B 16 64,65,66,67 ET352,ET353,ET354,ET355

ETC 0 B 26.1J Panel 00 / B 17 68,69,70,71 ET356,ET357,ET358,ET359

ETC 0 B 26.1R Panel 00 / B 18 72,73,74,75 ET360,ET361,ET362,ET363

ETC 0 B 26.1Z Panel 00 / B 19 76,77,78,79 ET364,ET365,ET366,ET367

ETC 1 B 28.1A Panel 00 / B 20 80,81,82,83 ET640,ET641,ET642,ET643

ETC 1 B 28.1J Panel 00 / B 21 84,85,86,87 ET644,ET645,ET646,ET647

ETC 1 B 28.1R Panel 00 / B 22 88,89,90,91 ET648,ET649,ET650,ET651

ETC 1 B 28.1Z Panel 00 / B 23 92,93,94,95 ET652,ET653,ET654,ET655

ETC 1 B 29.1A Panel 00 / B 24 96,97,98,99 ET624,ET625,ET626,ET627

ETC 1 B 29.1J Panel 00 / B 25 100,101,102,103 ET628,ET629,ET630,ET631

ETC 1 B 29.1R Panel 00 / B 26 104,105,106,107 ET632,ET633,ET634,ET635

ETC 1 B 29.1Z Panel 00 / B 27 108,109,110,111 ET636,ET637,ET638,ET639

ETC 1 B 30.1A Panel 00 / B 28 112,113,114,115 ET512,ET513,ET514,ET515

ETC 1 B 30.1J Panel 00 / B 29 116,117,118,119 ET516,ET517,ET518,ET519

ETC 1 B 30.1R Panel 00 / B 30 120,121,122,123 ET520,ET521,ET522,ET523

ETC 1 B 30.1Z Panel 00 / B 31 124,125,126,127 ET524,ET525,ET526,ET527

ETC 1 B 31.1A Panel 00 / B 32 128,129,130,131 ET528,ET529,ET530,ET531

Table 10 Balanced panels in first deliveries

Page 21: ET

DN70617303Issue 1-0

21

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

ETC 1 B 31.1J Panel 00 / B 33 132,133,134,135 ET532,ET533,ET534,ET535

ETC 1 B 31.1R Panel 00 / B 34 136,137,138,139 ET536,ET537,ET538,ET539

ETC 1 B 31.1Z Panel 00 / B 35 140,141,142,143 ET540,ET541,ET542,ET543

ETC 1 B 32.1A Panel 00 / B 36 144,145,146,147 ET544,ET545,ET546,ET547

ETC 1 B 32.1J Panel 00 / B 37 148,149,150,151 ET548,ET549,ET550,ET551

ETC 1 B 32.1R Panel 00 / B 38 152,153,154,155 ET552,ET553,ET554,ET555

ETC 1 B 32.1Z Panel 00 / B 39 156,157,158,159 ET556,ET557,ET558,ET559

ETC 1 B 33.1A Panel 00 / B 40 160,161,162,163 ET560,ET561,ET562,ET563

ETC 1 B 33.1J Panel 00 / B 41 164,165,166,167 ET564,ET565,ET566,ET567

ETC 1 B 33.1R Panel 00 / B 42 168,169,170,171 ET568,ET569,ET570,ET571

ETC 1 B 33.1Z Panel 00 / B 43 172,173,174,175 ET572,ET573,ET574,ET575

ETC 1 B 34.1A Panel 00 / B 44 176,177,178,179 ET576,ET577,ET578,ET579

ETC 1 B 34.1J Panel 00 / B 45 180,181,182,183 ET580,ET581,ET582,ET583

ETC 1 B 34.1R Panel 00 / B 46 184,185,186,187 ET584,ET585,ET586,ET587

ETC 1 B 34.1Z Panel 00 / B 47 188,189,190,191 ET588,ET589,ET590,ET591

ETC 1 B 35.1A Panel 00 / B 48 192,193,194,195 ET592,ET593,ET594,ET595

ETC 1 B 35.1J Panel 00 / B 49 196,197,198,199 ET596,ET597,ET598,ET599

ETC 1 B 35.1R Panel 00 / B 50 200,201,202,203 ET600,ET601,ET602,ET603

ETC 1 B 35.1Z Panel 00 / B 51 204,205,206,207 ET604,ET605,ET606,ET607

ETC 1 B 36.1A Panel 00 / B 52 208,209,210,211 ET608,ET609,ET610,ET611

ETC 1 B 36.1J Panel 00 / B 53 212,213,214,215 ET612,ET613,ET614,ET615

ETC 1 B 36.1R Panel 00 / B 54 216,217,218,219 ET616,ET617,ET618,ET619

ETC 1 B 36.1Z Panel 00 / B 55 220,221,222,223 ET620,ET621,ET622,ET623

GTIC 0 B 10.1A Panel 00 / B 56 224,225,226,227ET1392,ET1393,ET1394,ET1395

GTIC 0 B 10.1J Panel 00 / B 57 228,229,230,231ET1396,ET1397,ET1398,ET1399

GTIC 0 B 10.1R Panel 00 / B 58 232,233,234,235ET1400,ET1401,ET1402,ET1403

GTIC 0 B 10.1Z Panel 00 / B 59 236,237,238,239ET1404,ET1405,ET1406,ET1407

GTIC 0 B 11.1A Panel 00 / B 60 240,241,242,243ET1280,ET1281,ET1282,ET1283

GTIC 0 B 11.1J Panel 00 / B 61 244,245,246,247ET1284,ET1285,ET1286,ET1287

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 10 Balanced panels in first deliveries (Cont.)

Page 22: ET

22 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

GTIC 0 B 11.1R Panel 00 / B 62 248,249,250,251ET1288,ET1289,ET1290,ET1291

GTIC 0 B 11.1Z Panel 00 / B 63 252,253,254,255ET1292,ET1293,ET1294,ET1295

GTIC 1 B 10.1A Panel 01 / B 00 00,01,02,03ET1920,ET1921,ET1922,ET1923

GTIC 1 B 10.1J Panel 01 / B 01 04,05,06,07ET1924,ET1925,ET1926,ET1927

GTIC 1 B 10.1R Panel 01 / B 02 08,09,10,11ET1928,ET1929,ET1930,ET1931

GTIC 1 B 10.1Z Panel 01 / B 03 12,13,14,15ET1932,ET1933,ET1934,ET1935

GTIC 1 B 11.1A Panel 01 / B 04 16,17,18,19ET1936,ET1937,ET1938,ET1939

GTIC 1 B 11.1J Panel 01 / B 05 20,21,22,23ET1940,ET1941,ET1942,ET1943

GTIC 1 B 11.1R Panel 01 / B 06 24,25,26,27ET1944,ET1945,ET1946,ET1947

GTIC 1 B 11.1Z Panel 01 / B 07 28,29,30,31ET1948,ET1949,ET1950,ET1951

GTIC 1 B 12.1A Panel 01 / B 08 32,33,34,35ET1952,ET1953,ET1954,ET1955

GTIC 1 B 12.1J Panel 01 / B 09 36,37,38,39ET1956,ET1957,ET1958,ET1959

GTIC 1 B 12.1R Panel 01 / B 10 40,41,42,43ET1960,ET1961,ET1962,ET1963

GTIC 1 B 12.1Z Panel 01 / B 11 44,45,46,47ET1964,ET1965,ET1966,ET1967

GTIC 1 B 13.1A Panel 02 / B 00 00,01,02,03ET1968,ET1969,ET1970,ET1971

GTIC 1 B 13.1J Panel 02 / B 01 04,05,06,07ET1972,ET1973,ET1974,ET1975

GTIC 1 B 13.1R Panel 02 / B 02 08,09,10,11ET1976,ET1977,ET1978,ET1979

GTIC 1 B 13.1Z Panel 02 / B 03 12,13,14,15ET1980,ET1981,ET1982,ET1983

GTIC 1 B 14.1A Panel 02 / B 04 16,17,18,19ET1984,ET1985,ET1986,ET1987

GTIC 1 B 14.1J Panel 02 / B 05 20,21,22,23ET1988,ET1989,ET1990,ET1991

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 10 Balanced panels in first deliveries (Cont.)

Page 23: ET

DN70617303Issue 1-0

23

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

GTIC 1 B 14.1R Panel 02 / B 06 24,25,26,27ET1992,ET1993,ET1994,ET1995

GTIC 1 B 14.1Z Panel 02 / B 07 28,29,30,31ET1996,ET1997,ET1998,ET1999

GTIC 1 B 15.1A Panel 02 / B 08 32,33,34,35ET2000,ET2001,ET2002,ET2003

GTIC 1 B 15.1J Panel 02 / B 09 36,37,38,39ET2004,ET2005,ET2006,ET2007

GTIC 1 B 15.1R Panel 02 / B 10 40,41,42,43ET2008,ET2009,ET2010,ET2011

GTIC 1 B 15.1Z Panel 02 / B 11 44,45,46,47ET2012,ET2013,ET2014,ET2015

GTIC 1 B 16.1A Panel 03 / B 00 00,01,02,03ET2016,ET2017,ET2018,ET2019

GTIC 1 B 16.1J Panel 03 / B 01 04,05,06,07ET2020,ET2021,ET2022,ET2023

GTIC 1 B 16.1R Panel 03 / B 02 08,09,10,11ET2024,ET2025,ET2026,ET2027

GTIC 1 B 16.1Z Panel 03 / B 03 12,13,14,15ET2028,ET2029,ET2030,ET2031

GTIC 1 B 17.1A Panel 03 / B 04 16,17,18,19ET2032,ET2033,ET2034,ET2035

GTIC 1 B 17.1J Panel 03 / B 05 20,21,22,23ET2036,ET2037,ET2038,ET2039

GTIC 1 B 17.1R Panel 03 / B 06 24,25,26,27ET2040,ET2041,ET2042,ET2043

GTIC 1 B 17.1Z Panel 03 / B 07 28,29,30,31ET2044,ET2045,ET2046,ET2047

ETC 2 B 19.1A Panel 03 / B 08 32,33,34,35ET1136,ET1137,ET1138,ET1139

ETC 2 B 19.1J Panel 03 / B 09 36,37,38,39ET1140,ET1141,ET1142,ET1143

ETC 2 B 19.1R Panel 03 / B 10 40,41,42,43ET1140,ET1141,ET1142,ET1143

ETC 2 B 19.1Z Panel 03 / B 11 44,45,46,47ET1140,ET1141,ET1142,ET1143

ETC 2 B 20.1A Panel 04 / B 00 00,01,02,03ET1024,ET1025,ET1026,ET1027

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 10 Balanced panels in first deliveries (Cont.)

Page 24: ET

24 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

ETC 2 B 20.1J Panel 04 / B 01 04,05,06,07ET1028,ET1029,ET1030,ET1031

ETC 2 B 20.1R Panel 04 / B 02 08,09,10,11ET1032,ET1033,ET1034,ET1035

ETC 2 B 20.1Z Panel 04 / B 03 12,13,14,15ET1036,ET1037,ET1038,ET1039

ETC 2 B 21.1A Panel 04 / B 04 16,17,18,19ET1040,ET1041,ET1042,ET1043

ETC 2 B 21.1J Panel 04 / B 05 20,21,22,23ET1044,ET1045,ET1046,ET1047

ETC 2 B 21.1R Panel 04 / B 06 24,25,26,27ET1048,ET1049,ET1050,ET1051

ETC 2 B 21.1Z Panel 04 / B 07 28,29,30,31ET1052,ET1053,ET1054,ET1055

ETC 2 B 22.1A Panel 04 / B 08 32,33,34,35ET1056,ET1057,ET1058,ET1059

ETC 2 B 22.1J Panel 04 / B 09 36,37,38,39ET1060,ET1061,ET1062,ET1063

ETC 2 B 22.1R Panel 04 / B 10 40,41,42,43ET1064,ET1065,ET1066,ET1067

ETC 2 B 22.1Z Panel 04 / B 11 44,45,46,47ET1068,ET1069,ET1070,ET1071

ETC 2 B 23.1A Panel 04 / B 12 48,49,50,51ET1072,ET1073,ET1074,ET1075

ETC 2 B 23.1J Panel 04 / B 13 52,53,54,55ET1076,ET1077,ET1078,ET1079

ETC 2 B 23.1R Panel 04 / B 14 56,57,58,59ET1080,ET1081,ET1082,ET1083

ETC 2 B 23.1Z Panel 04 / B 15 60,61,62,63ET1084,ET1085,ET1086,ET1087

ETC 2 B 24.1A Panel 04 / B 16 64,65,66,67ET1088,ET1089,ET1090,ET1091

ETC 2 B 24.1J Panel 04 / B 17 68,69,70,71ET1092,ET1093,ET1094,ET1095

ETC 2 B 24.1R Panel 04 / B 18 72,73,74,75ET1096,ET1097,ET1098,ET1099

ETC 2 B 24.1Z Panel 04 / B 19 76,77,78,79ET1100,ET1101,ET1102,ET1103

ETC 2 B 25.1A Panel 04 / B 20 80,81,82,83ET1104,ET1105,ET1106,ET1107

ETC 2 B 25.1J Panel 04 / B 21 84,85,86,87ET1108,ET1109,ET1110,ET1111

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 10 Balanced panels in first deliveries (Cont.)

Page 25: ET

DN70617303Issue 1-0

25

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

ETC 2 B 25.1R Panel 04 / B 22 88,89,90,91ET1112,ET1113,ET1114,ET1115

ETC 2 B 25.1Z Panel 04 / B 23 92,93,94,95ET1116,ET1117,ET1118,ET1119

ETC 2 B 26.1A Panel 04 / B 24 96,97,98,99ET1120,ET1121,ET1122,ET1123

ETC 2 B 26.1J Panel 04 / B 25 100,101,102,103ET1124,ET1125,ET1126,ET1127

ETC 2 B 26.1R Panel 04 / B 26 104,105,106,107ET1128,ET1129,ET1130,ET1131

ETC 2 B 26.1Z Panel 04 / B 27 108,109,110,111ET1132,ET1133,ET1134,ET1135

ETC 3 B 28.1A Panel 04 / B 28 112,113,114,115 ET896,ET897,ET898,ET899

ETC 3 B 28.1J Panel 04 / B 29 116,117,118,119 ET900,ET901,ET902,ET903

ETC 3 B 28.1R Panel 04 / B 30 120,121,122,123 ET904,ET905,ET906,ET907

ETC 3 B 28.1Z Panel 04 / B 31 124,125,126,127 ET908,ET909,ET910,ET911

ETC 3 B 29.1A Panel 04 / B 32 128,129,130,131 ET880,ET881,ET882,ET883

ETC 3 B 29.1J Panel 04 / B 33 132,133,134,135 ET884,ET885,ET886,ET887

ETC 3 B 29.1R Panel 04 / B 34 136,137,138,139 ET888,ET889,ET890,ET891

ETC 3 B 29.1Z Panel 04 / B 35 140,141,142,143 ET892,ET893,ET894,ET895

ETC 3 B 30.1A Panel 04 / B 36 144,145,146,147 ET768,ET769,ET770,ET771

ETC 3 B 30.1J Panel 04 / B 37 148,149,150,151 ET772,ET773,ET774,ET775

ETC 3 B 30.1R Panel 04 / B 38 152,153,154,155 ET776,ET777,ET778,ET779

ETC 3 B 30.1Z Panel 04 / B 39 156,157,158,159 ET780,ET781,ET782,ET783

ETC 3 B 31.1A Panel 04 / B 40 160,161,162,163 ET784,ET785,ET786,ET787

ETC 3 B 31.1J Panel 04 / B 41 164,165,166,167 ET788,ET789,ET790,ET791

ETC 3 B 31.1R Panel 04 / B 42 168,169,170,171 ET792,ET793,ET794,ET795

ETC 3 B 31.1Z Panel 04 / B 43 172,173,174,175 ET796,ET797,ET798,ET799

ETC 3 B 32.1A Panel 04 / B 44 176,177,178,179 ET800,ET801,ET802,ET803

ETC 3 B 32.1J Panel 04 / B 45 180,181,182,183 ET804,ET805,ET806,ET807

ETC 3 B 32.1R Panel 04 / B 46 184,185,186,187 ET808,ET809,ET810,ET811

ETC 3 B 32.1Z Panel 04 / B 47 188,189,190,191 ET812,ET813,ET814,ET815

ETC 3 B 33.1A Panel 04 / B 48 192,193,194,195 ET816,ET817,ET818,ET819

ETC 3 B 33.1J Panel 04 / B 49 196,197,198,199 ET820,ET821,ET822,ET823

ETC 3 B 33.1R Panel 04 / B 50 200,201,202,203 ET824,ET825,ET826,ET827

ETC 3 B 33.1Z Panel 04 / B 51 204,205,206,207 ET828,ET829,ET830,ET831

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 10 Balanced panels in first deliveries (Cont.)

Page 26: ET

26 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

The equipping order of the connector panels in the cabling cabinet in upgrade deliveries is presented in the following table.

ETC 3 B 34.1A Panel 04 / B 52 208,209,210,211 ET832,ET833,ET834,ET835

ETC 3 B 34.1J Panel 04 / B 53 212,213,214,215 ET836,ET837,ET838,ET839

ETC 3 B 34.1R Panel 04 / B 54 216,217,218,219 ET840,ET841,ET842,ET843

ETC 3 B 34.1Z Panel 04 / B 55 220,221,222,223 ET844,ET845,ET846,ET847

ETC 3 B 35.1A Panel 04 / B 56 224,225,226,227 ET848,ET849,ET850,ET851

ETC 3 B 35.1J Panel 04 / B 57 228,229,230,231 ET852,ET853,ET854,ET855

ETC 3 B 35.1R Panel 04 / B 58 232,233,234,235 ET856,ET857,ET858,ET859

ETC 3 B 35.1Z Panel 04 / B 59 236,237,238,239 ET860,ET861,ET862,ET863

ETC 3 B 36.1A Panel 04 / B 60 240,241,242,243 ET864,ET865,ET866,ET867

ETC 3 B 36.1J Panel 04 / B 61 244,245,246,247 ET868,ET869,ET870,ET871

ETC 3 B 36.1R Panel 04 / B 62 248,249,250,251 ET872,ET873,ET874,ET875

ETC 3 B 36.1Z Panel 04 / B 63 252,253,254,255 ET876,ET877,ET878,ET879

GTIC 0 B 12.1A Panel T00 / B 00 00,01,02,03ET1296,ET1297,ET1298,ET1299

GTIC 0 B 12.1J Panel T00 / B 01 04,05,06,07ET1300,ET1301,ET1302,ET1303

GTIC 0 B 12.1R Panel T00 / B 02 08,09,10,11ET1304,ET1305,ET1306,ET1307

GTIC 0 B 12.1Z Panel T00 / B 03 12,13,14,15ET1308,ET1309,ET1310,ET1311

GTIC 0 B 13.1A Panel T00 / B 04 16,17,18,19ET1312,ET1313,ET1314,ET1315

GTIC 0 B 13.1J Panel T00 / B 05 20,21,22,23ET1316,ET1317,ET1318,ET1319

GTIC 0 B 13.1R Panel T00 / B 06 24,25,26,27ET1320,ET1321,ET1322,ET1323

GTIC 0 B 13.1Z Panel T00 / B 07 28,29,30,31ET1324,ET1325,ET1326,ET1327

GTIC 0 B 14.1A Panel T00 / B 08 32,33,34,35ET1328,ET1329,ET1330,ET1331

GTIC 0 B 14.1J Panel T00 / B 09 36,37,38,39ET1332,ET1333,ET1334,ET1335

GTIC 0 B 14.1R Panel T00 / B 10 40,41,42,43ET1336,ET1337,ET1338,ET1339

GTIC 0 B 14.1Z Panel T00 / B 11 44,45,46,47ET1340,ET1341,ET1342,ET1343

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 10 Balanced panels in first deliveries (Cont.)

Page 27: ET

DN70617303Issue 1-0

27

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

ETC 0 B 04.1A Panel 04 / B 61 244,245,246,247 ET560,ET561,ET562,ET563

ETC 0 B 04.1J Panel 04 / B 62 248,249,250,251 ET564,ET565,ET566,ET567

ETC 0 B 04.1R Panel 04 / B 63 252,253,254,255 ET568,ET569,ET570,ET571

ETC 0 B 04.1Z Panel 04 / B 58 232,233,234,235 ET572,ET573,ET574,ET575

ETC 1 B 01.1A Panel 04 / B 59 236,237,238,239 ET576,ET577,ET578,ET579

ETC 1 B 01.1J Panel 04 / B 60 240,241,242,243 ET580,ET581,ET582,ET583

ETC 1 B 01.1R Panel 04 / B 55 220,221,222,223 ET584,ET585,ET586,ET587

ETC 1 B 01.1Z Panel 04 / B 56 224,225,226,227 ET588,ET589,ET590,ET591

ETC 1 B 02.1A Panel 04 / B 57 228,229,230,231 ET592,ET593,ET594,ET595

ETC 1 B 02.1J Panel 04 / B 52 208,209,210,211 ET596,ET597,ET598,ET599

ETC 1 B 02.1R Panel 04 / B 53 212,213,214,215 ET600,ET601,ET602,ET603

ETC 1 B 02.1Z Panel 04 / B 54 216,217,218,219 ET604,ET605,ET606,ET607

ETC 1 B 03.1A Panel 04 / B 49 196,197,198,199 ET608,ET609,ET610,ET611

ETC 1 B 03.1J Panel 04 / B 50 200,201,202,203 ET612,ET613,ET614,ET615

ETC 1 B 03.1R Panel 04 / B 51 204,205,206,207 ET616,ET617,ET618,ET619

ETC 1 B 03.1Z Panel 04 / B 47 188,189,190,191 ET620,ET621,ET622,ET623

ETC 1 B 04.1A Panel 04 / B 48 192,193,194,195 ET624,ET625,ET626,ET627

ETC 1 B 04.1J Panel 04 / B 44 176,177,178,179 ET628,ET629,ET630,ET631

ETC 1 B 04.1R Panel 04 / B 45 180,181,182,183 ET632,ET633,ET634,ET635

ETC 1 B 04.1Z Panel 04 / B 46 184,185,186,187 ET636,ET637,ET638,ET639

GTIC 0 / ETC 5

B 01.1A (GTIC 0) / B03.1A (ETC 5) Panel 04 / B 41 164,165,166,167 ET904,ET905,ET906,ET907

GTIC 0 / ETC 5

B 01.1J (GTIC 0) / B03.1J (ETC 5) Panel 04 / B 42 168,169,170,171 ET908,ET909,ET910,ET911

GTIC 0 / ETC 5

B 01.1R (GTIC 0) / B03.1R (ETC 5) Panel 04 / B 43 172,173,174,175 ET912,ET913,ET914,ET915

GTIC 0 / ETC 5

B 01.1Z (GTIC 0) / B03.1Z (ETC 5) Panel 04 / B 38 152,153,154,155 ET916,ET917,ET918,ET919

GTIC 0 / ETC 5

B 02.1A (GTIC 0) / B04.1A (ETC 5) Panel 04 / B 39 156,157,158,159 ET920,ET921,ET922,ET923

GTIC 0 / ETC 5

B 02.1J (GTIC 0) / B04.1J (ETC 5) Panel 04 / B 40 160,161,162,163 ET924,ET925,ET926,ET927

GTIC 0 / ETC 5

B 02.1R (GTIC 0) / B04.1R (ETC 5) Panel 04 / B 35 140,141,142,143 ET928,ET929,ET930,ET931

GTIC 0 / ETC 5

B 02.1Z (GTIC 0) / B04.1Z (ETC 5) Panel 04 / B 36 144,145,146,147 ET932,ET933,ET934,ET935

Table 11 Balanced panels in upgrade deliveries

Page 28: ET

28 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

GTIC 0 / ETC 5

B 03.1A (GTIC 0) / B05.1A (ETC 5) Panel 04 / B 37 148,149,150,151 ET936,ET937,ET938,ET939

GTIC 0 / ETC 5

B 03.1J (GTIC 0) / B05.1J (ETC 5) Panel 04 / B 32 128,129,130,131 ET940,ET941,ET942,ET943

GTIC 0 / ETC 5

B 03.1R (GTIC 0) / B05.1R (ETC 5) Panel 04 / B 33 132,133,134,135 ET944,ET945,ET946,ET947

GTIC 0 / ETC 5

B 03.1Z (GTIC 0) / B05.1Z (ETC 5) Panel 04 / B 34 136,137,138,139 ET948,ET949,ET950,ET951

GTIC 0 / ETC 5

B 04.1A (GTIC 0) / B06.1A (ETC 5) Panel 04 / B 29 116,117,118,119 ET816,ET817,ET818,ET819

GTIC 0 / ETC 5

B 04.1J (GTIC 0) / B06.1J (ETC 5) Panel 04 / B 30 120,121,122,123 ET820,ET821,ET822,ET823

GTIC 0 / ETC 5

B 04.1R (GTIC 0) / B06.1R (ETC 5) Panel 04 / B 31 124,125,126,127 ET824,ET825,ET826,ET827

GTIC 0 / ETC 5

B 04.1Z (GTIC 0) / B06.1Z (ETC 5) Panel 04 / B 26 104,105,106,107 ET828,ET829,ER830,ET831

GTIC 0 / ETC 5

B 05.1A (GTIC 0) / B07.1A (ETC 5) Panel 04 / B 27 108,109,110,111

ET1072,ET1073,ET1074,ET1075

GTIC 0 / ETC 5

B 05.1J (GTIC 0) / B07.1J (ETC 5) Panel 04 / B 28 112,113,114,115

ET1076,ET1077,ET1078,ET1079

GTIC 0 / ETC 5

B 05.1R (GTIC 0) / B07.1R (ETC 5) Panel 04 / B 23 92,93,94,95

ET1080,ET1081,ET1082,ET1083

GTIC 0 / ETC 5

B 05.1Z (GTIC 0) / B07.1Z (ETC 5) Panel 04 / B 24 96,97,98,99

ET1084,ET1085,ET1086,ET1087

GTIC 0 / ETC 5

B 06.1A (GTIC 0) / B08.1A (ETC 5) Panel 04 / B 25 100,101,102,103

ET1328,ET1329,ET1330,ET1331

GTIC 0 / ETC 5

B 06.1J (GTIC 0) / B08.1J (ETC 5) Panel 04 / B 20 80,81,82,83

ET1332,ET1333,ET1334,ET1335

GTIC 0 / ETC 5

B 06.1R (GTIC 0) / B08.1R (ETC 5) Panel 04 / B 21 84,85,86,87

ET1336,ET1337,ET1338,ET1339

GTIC 0 / ETC 5

B 06.1Z (GTIC 0) / B08.1Z (ETC 5) Panel 04 / B 22 88,89,90,91

ET1340,ET1341,ET1342,ET1343

GTIC 0 B 07.1A Panel 04 / B 17 68,69,70,71ET1792,ET1793,ET1794,ET1795

GTIC 0 B 07.1J Panel 04 / B 18 72,73,74,75ET1796,ET1797,ET1798,ET1799

GTIC 0 B 07.1R Panel 04 / B 19 76,77,78,79ET1800,ET1801,ET1802,ET1803

GTIC 0 B 07.1Z Panel 04 / B 15 60,61,62,63ET1804,ET1805,ET1806,ET1807

GTIC 0 B 08.1A Panel 04 / B 16 64,65,66,67ET1808,ET1809,ET1810,ET1811

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 11 Balanced panels in upgrade deliveries (Cont.)

Page 29: ET

DN70617303Issue 1-0

29

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

GTIC 0 B 08.1J Panel 04 / B 12 48,49,50,51ET1812,ET1813,ET1814,ET1815

GTIC 0 B 08.1R Panel 04 / B 13 52,53,54,55ET1816,ET1817,ET1818,ET1819

GTIC 0 B 08.1Z Panel 04 / B 14 56,57,58,59ET1820,ET1821,ET1822,ET1823

GTIC 1 B 01.1A Panel 04 / B 09 36,37,38,39ET1408,ET1409,ET1410,ET1411

GTIC 1 B 01.1J Panel 04 / B 10 40,41,42,43ET1412,ET1413,ET1414,ET1415

GTIC 1 B 01.1R Panel 04 / B 11 44,45,46,47ET1416,ET1417,ET1418,ET1419

GTIC 1 B 01.1Z Panel 04 / B 06 24,25,26,27ET1420,ET1421,ET1422,ET1423

GTIC 1 B 02.1A Panel 04 / B 07 28,29,30,31ET1424,ET1425,ET1426,ET1427

GTIC 1 B 02.1J Panel 04 / B 08 32,33,34,35ET1428,ET1429,ET1430,ET1431

GTIC 1 B 02.1R Panel 04 / B 03 12,13,14,15ET1432,ET1433,ET1434,ET1435

GTIC 1 B 02.1Z Panel 04 / B 04 16,17,18,19ET1436,ET1437,ET1438,ET1439

GTIC 1 B 03.1A Panel 04 / B 05 20,21,22,23ET1440,ET1441,ET1442,ET1443

GTIC 1 B 03.1J Panel 04 / B 00 00,01,02,03ET1444,ET1445,ET1446,ET1447

GTIC 1 B 03.1R Panel 04 / B 01 04,05,06,07ET1448,ET1449,ET1450,ET1451

GTIC 1 B 03.1Z Panel 04 / B 02 08,09,10,11ET1452,ET1453,ET1454,ET1455

GTIC 1 B 04.1A Panel 03 / B 09 36,37,38,39ET1456,ET1457,ET1458,ET1459

GTIC 1 B 04.1J Panel 03 / B 10 40,41,42,43ET1460,ET1461,ET1462,ET1463

GTIC 1 B 04.1R Panel 03 / B 11 44,45,46,47ET1464,ET1465,ET1466,ET1467

GTIC 1 B 04.1Z Panel 03 / B 06 24,25,26,27ET1468,ET1469,ET1470,ET1471

GTIC 1 B 05.1A Panel 03 / B 07 28,29,30,31ET1472,ET1473,ET1474,ET1475

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 11 Balanced panels in upgrade deliveries (Cont.)

Page 30: ET

30 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

GTIC 1 B 05.1J Panel 03 / B 08 32,33,34,35ET1476,ET1477,ET1478,ET1479

GTIC 1 B 05.1R Panel 03 / B 03 12,13,14,15ET1480,ET1481,ET1482,ET1483

GTIC 1 B 05.1Z Panel 03 / B 04 16,17,18,19ET1484,ET1485,ET1486,ET1487

GTIC 1 B 06.1A Panel 03 / B 05 20,21,22,23ET1488,ET1489,ET1490,ET1491

GTIC 1 B 06.1J Panel 03 / B 00 00,01,02,03ET1492,ET1493,ET1494,ET1495

GTIC 1 B 06.1R Panel 03 / B 01 04,05,06,07ET1496,ET1497,ET1498,ET1499

GTIC 1 B 06.1Z Panel 03 / B 02 08,09,10,11ET1500,ET1501,ET1502,ET1503

GTIC 1 B 07.1A Panel 02 / B 09 36,37,38,39ET1504,ET1505,ET1506,ET1507

GTIC 1 B 07.1J Panel 02 / B 10 40,41,42,43ET1508,ET1509,ET1510,ET1511

GTIC 1 B 07.1R Panel 02 / B 11 44,45,46,47ET1512,ET1513,ET1514,ET1515

GTIC 1 B 07.1Z Panel 02 / B 06 24,25,26,27ET1516,ET1517,ET1518,ET1519

GTIC 1 B 08.1A Panel 02 / B 07 28,29,30,31ET1520,ET1521,ET1522,ET1523

GTIC 1 B 08.1J Panel 02 / B 08 32,33,34,35ET1524,ET1525,ET1526,ET1527

GTIC 1 B 08.1R Panel 02 / B 03 12,13,14,15ET1528,ET1529,ET1530,ET1531

GTIC 1 B 08.1Z Panel 02 / B 04 16,17,18,19ET1532,ET1533,ET1534,ET1535

ETC 2 B 01.1A Panel 02 / B 05 20,21,22,23ET1344,ET1345,ET1346,ET1347

ETC 2 B 01.1J Panel 02 / B 00 00,01,02,03ET1348,ET1349,ET1350,ET1351

ETC 2 B 01.1R Panel 02 / B 01 04,05,06,07ET1352,ET1353,ET1354,ET1355

ETC 2 B 01.1Z Panel 02 / B 02 08,09,10,11ET1356,ET1357,ET1358,ET1359

ETC 2 B 02.1A Panel 01 / B 09 36,37,38,39ET1360,ET1361,ET1362,ET1363

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 11 Balanced panels in upgrade deliveries (Cont.)

Page 31: ET

DN70617303Issue 1-0

31

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

ETC 2 B 02.1J Panel 01 / B 10 40,41,42,43ET1364,ET1365,ET1366,ET1367

ETC 2 B 02.1R Panel 01 / B 11 44,45,46,47ET1368,ET1369,ET1370,ET1371

ETC 2 B 02.1Z Panel 01 / B 06 24,25,26,27ET1372,ET1373,ET1374,ET1375

ETC 2 B 03.1A Panel 01 / B 07 28,29,30,31ET1376,ET1377,ET1378,ET1379

ETC 2 B 03.1J Panel 01 / B 08 32,33,34,35ET1380,ET1381,ET1382,ET1383

ETC 2 B 03.1R Panel 01 / B 03 12,13,14,15ET1384,ET1385,ET1386,ET1387

ETC 2 B 03.1Z Panel 01 / B 04 16,17,18,19ET1388,ET1389,ET1390,ET1391

ETC 2 B 04.1A Panel 01 / B 05 20,21,22,23ET1392,ET1393,ET1394,ET1395

ETC 2 B 04.1J Panel 01 / B 00 00,01,02,03ET1396,ET1397,ET1398,ET1399

ETC 2 B 04.1R Panel 01 / B 01 04,05,06,07ET1400,ET1401,ET1402,ET1403

ETC 2 B 04.1Z Panel 01 / B 02 08,09,10,11ET1404,ET1405,ET1406,ET1407

ETC 2 B 05.1A Panel 00 / B 61 244,245,246,247ET1600,ET1601,ET1602,ET1603

ETC 2 B 05.1J Panel 00 / B 62 248,249,250,251ET1604,ET1605,ET1606,ET1607

ETC 2 B 05.1R Panel 00 / B 63 252,253,254,255ET1608,ET1609,ET1610,ET1611

ETC 2 B 05.1Z Panel 00 / B 58 232,233,234,235ET1612,ET1613,ET1614,ET1615

ETC 2 B 06.1A Panel 00 / B 59 236,237,238,239ET1616,ET1617,ET1618,ET1619

ETC 2 B 06.1J Panel 00 / B 60 240,241,242,243ET1620,ET1621,ET1622,ET1623

ETC 2 B 06.1R Panel 00 / B 55 220,221,222,223ET1624,ET1625,ET1626,ET1627

ETC 2 B 06.1Z Panel 00 / B 56 224,225,226,227ET1628,ET1629,ET1630,ET1631

ETC 2 B 07.1A Panel 00 / B 57 228,229,230,231ET1632,ET1633,ET1634,ET1635

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 11 Balanced panels in upgrade deliveries (Cont.)

Page 32: ET

32 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

ETC 2 B 07.1J Panel 00 / B 52 208,209,210,211ET1636,ET1637,ET1638,ET1639

ETC 2 B 07.1R Panel 00 / B 53 212,213,214,215ET1640,ET1641,ET1642,ET1643

ETC 2 B 07.1Z Panel 00 / B 54 216,217,218,219ET1644,ET1645,ET1646,ET1647

ETC 2 B 08.1A Panel 00 / B 49 196,197,198,199ET1648,ET1649,ET1650,ET1651

ETC 2 B 08.1J Panel 00 / B 50 200,201,202,203ET1652,ET1653,ET1654,ET1655

ETC 2 B 08.1R Panel 00 / B 51 204,205,206,207ET1656,ET1657,ET1658,ET1659

ETC 2 B 08.1Z Panel 00 / B 47 188,189,190,191ET1660,ET1661,ET1662,ET1663

ETC 3 B 01.1A Panel 00 / B 48 192,193,194,195ET1664,ET1665,ET1666,ET1667

ETC 3 B 01.1J Panel 00 / B 44 176,177,178,179ET1668,ET1669,ET1670,ET1671

ETC 3 B 01.1R Panel 00 / B 45 180,181,182,183ET1672,ET1673,ET1674,ET1675

ETC 3 B 01.1Z Panel 00 / B 46 184,185,186,187ET1676,ET1677,ET1678,ET1679

ETC 3 B 02.1A Panel 00 / B 41 164,165,166,167ET1680,ET1681,ET1682,ET1683

ETC 3 B 02.1J Panel 00 / B 42 168,169,170,171ET1684,ET1685,ET1686,ET1687

ETC 3 B 02.1R Panel 00 / B 43 172,173,174,175ET1688,ET1689,ET1690,ET1691

ETC 3 B 02.1Z Panel 00 / B 38 152,153,154,155ET1692,ET1693,ET1694,ET1695

ETC 3 B 03.1A Panel 00 / B 39 156,157,158,159ET1696,ET1697,ET1698,ET1699

ETC 3 B 03.1J Panel 00 / B 40 160,161,162,163ET1700,ET1701,ET1702,ET1703

ETC 3 B 03.1R Panel 00 / B 35 140,141,142,143ET1704,ET1705,ET1706,ET1707

ETC 3 B 03.1Z Panel 00 / B 36 144,145,146,147ET1708,ET1709,ET1710,ET1711

ETC 3 B 04.1A Panel 00 / B 37 148,149,150,151ET1712,ET1713,ET1714,ET1715

ETC 3 B 04.1J Panel 00 / B 32 128,129,130,131ET1716,ET1717,ET1718,ET1719

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 11 Balanced panels in upgrade deliveries (Cont.)

Page 33: ET

DN70617303Issue 1-0

33

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

ETC 3 B 04.1R Panel 00 / B 33 132,133,134,135ET1720,ET1721,ET1722,ET1723

ETC 3 B 04.1Z Panel 00 / B 34 136,137,138,139ET1724,ET1725,ET1726,ET1727

ETC 3 B 05.1A Panel 00 / B 29 116,117,118,119ET1728,ET1729,ET1730,ET1731

ETC 3 B 05.1J Panel 00 / B 30 120,121,122,123ET1732,ET1733,ET1734,ET1735

ETC 3 B 05.1R Panel 00 / B 31 124,125,126,127ET1736,ET1737,ET1738,ET1739

ETC 3 B 05.1Z Panel 00 / B 26 104,105,106,107ET1740,ET1741,ET1742,ET1743

ETC 3 B 06.1A Panel 00 / B 27 108,109,110,111ET1744,ET1745,ET1746,ET1747

ETC 3 B 06.1J Panel 00 / B 28 112,113,114,115ET1748,ET1749,ET1750,ET1751

ETC 3 B 06.1R Panel 00 / B 23 92,93,94,95ET1752,ET1753,ET1754,ET1755

ETC 3 B 06.1Z Panel 00 / B 24 96,97,98,99ET1756,ET1757,ET1758,ET1759

ETC 3 B 07.1A Panel 00 / B 25 100,101,102,103ET1760,ET1761,ET1762,ET1763

ETC 3 B 07.1J Panel 00 / B 20 80,81,82,83ET1764,ET1765,ET1766,ET1767

ETC 3 B 07.1R Panel 00 / B 21 84,85,86,87ET1768,ET1769,ET1770,ET1771

ETC 3 B 07.1Z Panel 00 / B 22 88,89,90,91ET1772,ET1773,ET1774,ET1775

ETC 3 B 08.1A Panel 00 / B 17 68,69,70,71ET1776,ET1777,ET1778,ET1779

ETC 3 B 08.1J Panel 00 / B 18 72,73,74,75ET1780,ET1781,ET1782,ET1783

ETC 3 B 08.1R Panel 00 / B 19 76,77,78,79ET1784,ET1785,ET1786,ET1787

ETC 3 B 08.1Z Panel 00 / B 15 60,61,62,63ET1788,ET1789,ET1790,ET1791

ETC 4 B 01.1A Panel 00 / B 16 64,65,66,67ET1920,ET1921,ET1922,ET1923

ETC 4 B 01.1J Panel 00 / B 12 48,49,50,51ET1924,ET1925,ET1926,ET1927

ETC 4 B 01.1R Panel 00 / B 13 52,53,54,55ET1928,ET1929,ET1930,ET1931

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 11 Balanced panels in upgrade deliveries (Cont.)

Page 34: ET

34 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

3.3 TCSM3iTwo installation options of the third-generation Transcoder Submultiplexer are available: the TCSM3i for stand-alone installation option and the TCSM3i for combined BSC/TCSM installation option. The TCSM3i for stand-alone installation option always has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does not have a cabling cabinet.

3.3.1 TCSM3i for stand-alone installation optionIn the TCSM3i for stand-alone installation option, the cabling cabinet is always mounted to the TCSA cabinet.

E1 (PCM) balanced trunk cable panel (CPETS-H)Two large balanced CPETS-H connector panels are used in the cabling cabinet mounted to the TCSA cabinet.

ETC 4 B 01.1Z Panel 00 / B 14 56,57,58,59ET1932,ET1933,ET1934,ET1935

ETC 4 B 02.1A Panel 00 / B 09 36,37,38,39ET1936,ET1937,ET1938,ET1939

ETC 4 B 02.1J Panel 00 / B 10 40,41,42,43ET1940,ET1941,ET1942,ET1943

ETC 4 B 02.1R Panel 00 / B 11 44,45,46,47ET1944,ET1945,ET1946,ET1947

ETC 4 B 02.1Z Panel 00 / B 06 24,25,26,27ET1948,ET1949,ET1950,ET1951

ETC 4 B 03.1A Panel 00 / B 07 28,29,30,31ET1952,ET1953,ET1954,ET1955

ETC 4 B 03.1J Panel 00 / B 08 32,33,34,35ET1956,ET1957,ET1958,ET1959

ETC 4 B 03.1R Panel 00 / B 03 12,13,14,15ET1960,ET1961,ET1962,ET1963

ETC 4 B 03.1Z Panel 00 / B 04 16,17,18,19ET1964,ET1965,ET1966,ET1967

ETC 4 B 04.1A Panel 00 / B 05 20,21,22,23ET1968,ET1969,ET1970,ET1971

ETC 4 B 04.1J Panel 00 / B 00 00,01,02,03ET1972,ET1973,ET1974,ET1975

ETC 4 B 04.1R Panel 00 / B 01 04,05,06,07ET1976,ET1977,ET1978,ET1979

ETC 4 B 04.1Z Panel 00 / B 02 08,09,10,11ET1980,ET1981,ET1982,ET1983

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 11 Balanced panels in upgrade deliveries (Cont.)

Page 35: ET

DN70617303Issue 1-0

35

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

The cables and connectors should meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the requirements of the FCC Part 68.

Recommended cable type for E1 trunk cables (CNIB) is presented in the following table and figure.

Figure 5 RJ45 connector cable (CNIB cable type) with four connectors

Equipping orderEquipping of ETs proceeds in steps. The equipping order in the cabling cabinet is pre-sented in the following table.

Panel number

Connector panel

0 CPETS-H

1 CPBP

2 CPBP

3 CPBP

4 CPETS-H

Table 12 Balanced connector panels for the TCSM3i

Cable type: 4x(4x2xAWG26/1) 120 Ω , insulated pairs, twisted, double-shielded, cross section 0.4 mm2

Cable connector: RJ45 modular connector plug (8-pole)

Table 13 Recommended cable type for E1 trunk cables (CNIB)

CONNECTOR

DN00206525

1 2 3 4

Page 36: ET

36 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

ETC car-tridge

From GT4C-A connector position

To panel / con-nector position

Front ports in CPETS-H panel

Front ports used for TR3 A-interface

ETC 0 B 01.1A Panel 0 / B 00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 01

ETC 0 B 01.1J Panel 0 / B 01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 02

ETC 0 B 01.1R Panel 0 / B 02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 03

ETC 0 B 01.1Z Panel 0 / B 03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 04

ETC 1 B 01.1A Panel 0 / B 04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 05

ETC 1 B 01.1J Panel 0 / B 05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 06

ETC 1 B 01.1R Panel 0 / B 06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 07

ETC 1 B 01.1Z Panel 0 / B 07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 08

ETC 2 B 01.1A Panel 0 / B 08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 09

ETC 2 B 01.1J Panel 0 / B 09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 10

ETC 2 B 01.1R Panel 0 / B 10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 11

ETC 2 B 01.1Z Panel 0 / B 11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 12

ETC 1 B 02.1A Panel 0 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 13

ETC 1 B 02.1J Panel 0 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 14

ETC 1 B 02.1R Panel 0 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 15

ETC 1 B 02.1Z Panel 0 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 16

ETC 0 B 02.1A Panel 0 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 01

ETC 0 B 02.1J Panel 0 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 02

ETC 0 B 02.1R Panel 0 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 03

ETC 0 B 02.1Z Panel 0 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 04

ETC 1 B 03.1A Panel 0 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 05

ETC 1 B 03.1J Panel 0 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 06

ETC 1 B 03.1R Panel 0 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 07

ETC 1 B 03.1Z Panel 0 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 08

ETC 2 B 02.1A Panel 0 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 09

ETC 2 B 02.1J Panel 0 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 10

ETC 2 B 02.1R Panel 0 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 11

ETC 2 B 02.1Z Panel 0 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 12

ETC 1 B 04.1A Panel 0 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 13

ETC 1 B 04.1J Panel 0 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 14

ETC 1 B 04.1R Panel 0 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 15

ETC 1 B 04.1Z Panel 0 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 16

ETC 0 B 03.1A Panel 0 / B32 128, 129, 130, 131 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 01

ETC 0 B 03.1J Panel 0 / B33 132, 133, 134, 135 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 02

Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface

Page 37: ET

DN70617303Issue 1-0

37

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

ETC 0 B 03.1R Panel 0 / B34 136, 137, 138, 139 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 03

ETC 0 B 03.1Z Panel 0 / B35 140, 141, 142, 143 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 04

ETC 1 B 05.1A Panel 0 / B36 144, 145, 146, 147 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 05

ETC 1 B 05.1J Panel 0 / B37 148, 149, 150, 151 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 06

ETC 1 B 05.1R Panel 0 / B38 152, 153, 154, 155 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 07

ETC 1 B 05.1Z Panel 0 / B39 156, 157, 158, 159 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 08

ETC 2 B 03.1A Panel 0 / B40 160, 161, 162, 163 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 09

ETC 2 B 03.1J Panel 0 / B41 164, 165, 166, 167 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 10

ETC 2 B 03.1R Panel 0 / B42 168, 169, 170, 171 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 11

ETC 2 B 03.1Z Panel 0 / B43 172, 173, 174, 175 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 12

ETC 1 B 06.1A Panel 0 / B44 176, 177, 178, 179 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 13

ETC 1 B 06.1J Panel 0 / B45 180, 181, 182, 183 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 14

ETC 1 B 06.1R Panel 0 / B46 184, 185, 186, 187 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 15

ETC 1 B 06.1Z Panel 0 / B47 188, 189, 190, 191 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 16

ETC 0 B 04.1A Panel 0 / B48 192, 193, 194, 195 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 01

ETC 0 B 04.1J Panel 0 / B49 196, 197, 198, 199 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 02

ETC 0 B 04.1R Panel 0 / B50 200, 201, 202, 203 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 03

ETC 0 B 04.1Z Panel 0 / B51 204, 205, 206, 207 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 04

ETC 1 B 07.1A Panel 0 / B52 208, 209, 210, 211 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 05

ETC 1 B 07.1J Panel 0 / B53 212, 213, 214, 215 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 06

ETC 1 B 07.1R Panel 0 / B54 216, 217, 218, 219 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 07

ETC 1 B 07.1Z Panel 0 / B55 220, 221, 222, 223 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 08

ETC 2 B 04.1A Panel 0 / B56 224, 225, 226, 227 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 09

ETC 2 B 04.1J Panel 0 / B57 228, 229, 230, 231 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 10

ETC 2 B 04.1R Panel 0 / B58 232, 233, 234, 235 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 11

ETC 2 B 04.1Z Panel 0 / B59 236, 237, 238, 239 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 12

ETC 1 B 08.1A Panel 0 / B60 240, 241, 242, 243 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 13

ETC 1 B 08.1J Panel 0 / B61 244, 245, 246, 247 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 14

ETC 1 B 08.1R Panel 0 / B62 248, 249, 250, 251 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 15

ETC 1 B 08.1Z Panel 0 / B63 252, 253, 254, 255 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 16

ETC 0 B 05.1A Panel 4 / B00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 01

ETC 0 B 05.1J Panel 4 / B01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 02

ETC 0 B 05.1R Panel 4 / B02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 03

ETC car-tridge

From GT4C-A connector position

To panel / con-nector position

Front ports in CPETS-H panel

Front ports used for TR3 A-interface

Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface (Cont.)

Page 38: ET

38 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804d10f1

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)

ETC 0 B 05.1Z Panel 4 / B03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 04

ETC 2 B 05.1A Panel 4 / B04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 05

ETC 2 B 05.1J Panel 4 / B05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 06

ETC 2 B 05.1R Panel 4 / B06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 07

ETC 2 B 05.1Z Panel 4 / B07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 08

ETC 0 B 06.1A Panel 4 / B08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 09

ETC 0 B 06.1J Panel 4 / B09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 10

ETC 0 B 06.1R Panel 4 / B10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 11

ETC 0 B 06.1Z Panel 4 / B11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 12

ETC 2 B 06.1A Panel 4 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 13

ETC 2 B 06.1J Panel 4 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 14

ETC 2 B 06.1R Panel 4 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 15

ETC 2 B 06.1Z Panel 4 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 16

ETC 0 B 07.1A Panel 4 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 01

ETC 0 B 07.1J Panel 4 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 02

ETC 0 B 07.1R Panel 4 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 03

ETC 0 B 07.1Z Panel 4 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 04

ETC 2 B 07.1A Panel 4 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 05

ETC 2 B 07.1J Panel 4 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 06

ETC 2 B 07.1R Panel 4 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 07

ETC 2 B 07.1Z Panel 4 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 08

ETC 0 B 08.1A Panel 4 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 09

ETC 0 B 08.1J Panel 4 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 10

ETC 0 B 08.1R Panel 4 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 11

ETC 0 B 08.1Z Panel 4 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 12

ETC 2 B 08.1A Panel 4 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 13

ETC 2 B 08.1J Panel 4 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 14

ETC 2 B 08.1R Panel 4 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 15

ETC 2 B 08.1Z Panel 4 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 16

ETC car-tridge

From GT4C-A connector position

To panel / con-nector position

Front ports in CPETS-H panel

Front ports used for TR3 A-interface

Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface (Cont.)

From car-tridge

TR3 unit slot From ET16 slot and connector position

ET panel / front ports through this cable

TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 128, 129, 130, 131

Table 15 CPETS-H balanced panels in the TCSM3i cabling cabinet - Ater-interface

Page 39: ET

DN70617303Issue 1-0

39

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) balanced trunk cable panels (CPETS-G andCPETS-H)

Id:0900d805804d10f1

3.3.2 TCSM3i for combined BSC/TCSM installation optionThe cabling cabinet is not used with the TCSA cabinet in the TCSM3i for combined BSC/TCSM installation option. Instead, the optical cabling from the front connectors of the ETS2 plug-in units is routed out of the cabinet through the CPGO at the cabinet top.

TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 132, 133, 134, 135

TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 136, 137, 138, 139

TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 140, 141, 142, 143

TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 144, 145, 146, 147

TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 148, 149, 150, 151

TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 152, 153, 154, 155

TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 156, 157, 158, 159

TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 160, 161, 162, 163

TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 164, 165, 166, 167

TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 168, 169, 170, 171

TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 172, 173, 174, 175

TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 176, 177, 178, 179

TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 180, 181, 182, 183

TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 184, 185, 186, 187

TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 188, 189, 190, 191

TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 192, 193, 194, 195

TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 196, 197, 198, 199

TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 200, 201, 202, 203

TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 204, 205, 206, 207

TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 208, 209, 210, 211

TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 212, 213, 214, 215

TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 216, 217, 218, 219

TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 220, 221, 222, 223

Notes

*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C car-tridge is used for transcoder connections of one BSC.

Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used for transcoder connections of two BSCs (one half of the TC2C cartridge for one BSC and the other half for the other BSC).

From car-tridge

TR3 unit slot From ET16 slot and connector position

ET panel / front ports through this cable

Table 15 CPETS-H balanced panels in the TCSM3i cabling cabinet - Ater-interface

Page 40: ET

40 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

4 E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

4.1 Connector panels CPETS-E and CPETS-F with RJ45 con-nectorsThe small CPETS-E connector panel and the large CPETS-F connector panels are used for E1/T1 (PCM) balanced trunk cables.

Cabling of the CPETS-E panels is described in the cabling lists delivered in the Site Doc-uments binder. The CPETS-E is installed at the BSCC cabinet top (one panel) or in the optional cabling cabinet (a total of four small panels, because there are three small panels in the cabinet and an additional small panel at the cabling cabinet top in first deliveries). The installation of the connector panel at the equipment cabinet top requires the use of Roof adapter (RACP) and the installation of the connector panel at the cabling cabinet top in first deliveries requires the use of Roof adapter 2 (RACP2).

For details of the panel, see figure Connector panel CPETS-E.

Figure 6 Connector panel CPETS-E

Cabling of the CPETS-F panels is described in the cabling lists delivered in the Site Doc-uments binder. The CPETS-F is installed in the optional cabling cabinet.

For details of the panel, see figure Connector panel CPETS-F.

CPETS-E

00 01 02 03 04 05 06 07 08 09 10 11

12 13 14 15 16 17 18 19 20 21 22 23

24 24 26 27 28 29 30 31 32 33 34 35

36 37 38 39 40 41 42 43 44 45 46 47

DN0626746

Page 41: ET

DN70617303Issue 1-0

41

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

Figure 7 Connector panel CPETS-F

4.2 Flexi BSCDepending on the maximum number ET interfaces, the BSC3i can be used either with or without a cabling cabinet.

CPETS-F00 01 02 03 04 05 06 07 08 09 10 11

12 13 14 15 16 17 18 19 20 21 22 23

24 25 26 27 28 29 30 31 32 33 34 35

36 37 38 39 40 41 42 43 44 45 46 47

48 49 50 51 52 53 54 55 56 57 58 59

60 61 62 63 64 65 66 67

68 69 70 71 72 73 74 75 76 77 78 79

80 81 82 83 84 85 86 87 88 89 90 91

92 93 94 95 96 97 98 99 100 101 102 103

104 105 106 107 108 109 110 111 112 113 114 115

116 117 118 119 120 121 122 123 124 125 126 127

128 129 130 131 132 133 134 135 136 137 138 139

140 141 142 143 144 145 146 147 148 149 150 151

152 153 154 155 156 157 158 159 160 161 162 163

164 165 166 167 168 169 170 171 172 173 174 175

176 177 178 179 180 181 182 183 184 185 186 187

188 189 190 191 192 193 194 195

196 197 198 199 200 201 202 203 204 205 206 207

208 209 210 211 212 213 214 215 216 217 218 219

220 221 222 223 224 225 226 227 228 229 230 231

232 233 234 235 236 237 238 239 240 241 242 243

244 245 246 247 248 249 250 251 252 253 254 255

DN0626407

Page 42: ET

42 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

4.2.1 Optional cabling cabinet is not usedThe optional cabling cabinet is not needed, if the number ET interfaces needed does not exceed 48.

The E1 and T1 trunk cable connector and in configuration is presented in the following table.

The external trunk cable (from the ET panel) and the connector should meet the require-ments of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connector should also meet the requirements of the FCC Part 68

Recommended cable type for T1 trunk cable (CNIS) is presented in the following table and figure.

Pin Signal Colour Remarks

1 R Orange/White Incoming direction

2 T White/Orange

3

4 R Blue/White Outgoing direction

5 T White/Blue

6

7

8

Table 16 E1 and T1 trunk cable connector, pin configuration

Cable type: 4 insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Filotex Milliflex3 SH G26/2x4)

Cable connec-tor:

RJ45 modular connector (8-pole)

Table 17 Recommended cable type for T1 trunk cables (CNIS)

Page 43: ET

DN70617303Issue 1-0

43

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

Figure 8 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables

Recommended cable type for E1 trunk cables (CNIA) is presented in the following table and figure.

Figure 9 RJ45 connector cable (CNIA cable type) with four connectors

The equipping order of the CPETS-E panel at the cabinet in the first deliveries top is pre-sented in the following table.

Cable type: 4x(2x2) insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Milliflex3 SH G26/4)

Cable connec-tor:

RJ45 modular connector plug (8-pole)

Table 18 Recommended cable type for E1 trunk cables (CNIA)

8

MODULAR CONNECTOR

SLEEVE

CABLE

IDENTIFICATIONSTICKER

DN98339941

CONNECTOR

DN00206525

1 2 3 4

Page 44: ET

44 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

The equipping order of the CPETS-E panel at the cabinet in the upgrade deliveries top is presented in the following table.

4.2.2 Optional cabling cabinet is usedIf more than 48 ET interfaces are needed, the cabling cabinet must be used.

ETC car-tridge

From SGC1C-A connector position

To CPETS-E connector position

Front ports in CPETS-E panel through this cable

Corresponding external ET numbers

ETC 0 B 19.1A B 00 00,01,02,03 ET368,ET369,ET370,ET371

ETC 0 B 19.1J B 01 04,05,06,07 ET372,ET373,ET374,ET375

ETC 0 B 19.1R B 02 08,09,10,11 ET376,ET377,ET378,ET379

ETC 0 B 19.1Z B 03 12,13,14,15 ET380,ET381,ET382,ET383

ETC 0 B 20.1A B 04 16,17,18,19 ET256,ET257,ET258,ET259

ETC 0 B 20.1J B 05 20,21,22,23 ET260,ET261,ET262,ET263

ETC 0 B 20.1R B 06 24,25,26,27 ET264,ET265,ET266,ET267

ETC 0 B 20.1Z B 07 28,29,30,31 ET268,ET269,ET270,ET271

ETC 0 B 21.1A B 08 32,33,34,35 ET272,ET273,ET274,ET275

ETC 0 B 21.1J B 09 36,37,38,39 ET276,ET277,ET278,ET279

ETC 0 B 21.1R B 10 40,41,42,43 ET280,ET281,ET282,ET283

ETC 0 B 21.1Z B 11 44,45,46,47 ET284,ET285,ET286,ET287

Table 19 Balanced panel at the BSCC cabinet top in first deliveries

ETC car-tridge

From GT6C-A connector position

To CPETS-E connector position

Front ports in CPETS-E panel through this cable

Corresponding external ET numbers

ETC 0 B 01.1A B 00 00,01,02,03 ET512,ET513,ET514,ET515

ETC 0 B 01.1J B 01 04,05,06,07 ET516,ET517,ET518,ET519

ETC 0 B 01.1R B 02 08,09,10,11 ET520,ET521,ET522,ET523

ETC 0 B 01.1Z B 03 12,13,14,15 ET524,ET525,ET526,ET527

ETC 0 B 02.1A B 04 16,17,18,19 ET528,ET529,ET530,ET531

ETC 0 B 02.1J B 05 20,21,22,23 ET532,ET533,ET534,ET535

ETC 0 B 02.1R B 06 24,25,26,27 ET536,ET537,ET538,ET539

ETC 0 B 02.1Z B 07 28,29,30,31 ET540,ET541,ET542,ET543

ETC 0 B 03.1A B 08 32,33,34,35 ET544,ET545,ET546,ET547

ETC 0 B 03.1J B 09 36,37,38,39 ET548,ET549,ET550,ET551

ETC 0 B 03.1R B 10 40,41,42,43 ET552,ET553,ET554,ET555

ETC 0 B 03.1Z B 11 44,45,46,47 ET556,ET557,ET558,ET559

Table 20 Balanced panel at the BSCC cabinet top in upgrade deliveries

Page 45: ET

DN70617303Issue 1-0

45

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)The following table shows the connector panels in the cabling cabinet.

The cables and the connectors should meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the requirements of the FCC Part 68.

Recommended cable type for T1 trunk cable (CNIS) is presented in the following table and figure.

Figure 10 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables

Recommended cable type for E1 trunk cables (CNIA) is presented in the following table and figure.

Panel number

Connector panel

T00 CPETS-E

0 CPETS-F

1 CPETS-E

2 CPETS-E

3 CPETS-E

4 CPETS-F

Table 21 Balanced connector panels in the cabling cabinet

Cable type: 4 insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Filotex Milliflex3 SH G26/2x4)

Cable connec-tor:

RJ45 modular connector (8-pole)

Table 22 Recommended cable type for T1 trunk cables (CNIS)

8

MODULAR CONNECTOR

SLEEVE

CABLE

IDENTIFICATIONSTICKER

DN98339941

Page 46: ET

46 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

Figure 11 RJ45 connector cable (CNIA cable type) with four connectors

Equipping orderThe equipping order in the cabling cabinet in the first deliveries presented in the follow-ing table.

Cable type: 4x(2x2) insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Milliflex3 SH G26/4)

Cable connec-tor:

RJ45 modular connector plug (8-pole)

Table 23 Recommended cable type for E1 trunk cables (CNIA)

CONNECTOR

DN00206525

1 2 3 4

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

ETC 0 B 22.1A Panel 00 / B 00 00,01,02,03 ET256,ET257,ET258,ET259

ETC 0 B 22.1J Panel 00 / B 01 04,05,06,07 ET260,ET261,ET262,ET263

ETC 0 B 22.1R Panel 00 / B 02 08,09,10,11 ET264,ET265,ET266,ET267

ETC 0 B 22.1Z Panel 00 / B 03 12,13,14,15 ET268,ET269,ET270,ET271

ETC 0 B 23.1A Panel 00 / B 04 16,17,18,19 ET304,ET305,ET306,ET307

ETC 0 B 23.1J Panel 00 / B 05 20,21,22,23 ET308,ET309,ET310,ET311

ETC 0 B 23.1R Panel 00 / B 06 24,25,26,27 ET312,ET313,ET314,ET315

ETC 0 B 23.1Z Panel 00 / B 07 28,29,30,31 ET316,ET317,ET318,ET319

ETC 0 B 24.1A Panel 00 / B 08 32,33,34,35 ET320,ET321,ET322,ET323

ETC 0 B 24.1J Panel 00 / B 09 36,37,38,39 ET324,ET325,ET326,ET327

ETC 0 B 24.1R Panel 00 / B 10 40,41,42,43 ET328,ET329,ET330,ET331

ETC 0 B 24.1Z Panel 00 / B 11 44,45,46,47 ET332,ET333,ET334,ET335

ETC 0 B 25.1A Panel 00 / B 12 48,49,50,51 ET336,ET337,ET338,ET339

Table 24 Balanced panels in first deliveries

Page 47: ET

DN70617303Issue 1-0

47

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

ETC 0 B 25.1J Panel 00 / B 13 52,53,54,55 ET340,ET341,ET342,ET343

ETC 0 B 25.1R Panel 00 / B 14 56,57,58,59 ET344,ET345,ET346,ET347

ETC 0 B 25.1Z Panel 00 / B 15 60,61,62,63 ET348,ET349,ET350,ET351

ETC 0 B 26.1A Panel 00 / B 16 64,65,66,67 ET352,ET353,ET354,ET355

ETC 0 B 26.1J Panel 00 / B 17 68,69,70,71 ET356,ET357,ET358,ET359

ETC 0 B 26.1R Panel 00 / B 18 72,73,74,75 ET360,ET361,ET362,ET363

ETC 0 B 26.1Z Panel 00 / B 19 76,77,78,79 ET364,ET365,ET366,ET367

ETC 1 B 28.1A Panel 00 / B 20 80,81,82,83 ET640,ET641,ET642,ET643

ETC 1 B 28.1J Panel 00 / B 21 84,85,86,87 ET644,ET645,ET646,ET647

ETC 1 B 28.1R Panel 00 / B 22 88,89,90,91 ET648,ET649,ET650,ET651

ETC 1 B 28.1Z Panel 00 / B 23 92,93,94,95 ET652,ET653,ET654,ET655

ETC 1 B 29.1A Panel 00 / B 24 96,97,98,99 ET624,ET625,ET626,ET627

ETC 1 B 29.1J Panel 00 / B 25 100,101,102,103 ET628,ET629,ET630,ET631

ETC 1 B 29.1R Panel 00 / B 26 104,105,106,107 ET632,ET633,ET634,ET635

ETC 1 B 29.1Z Panel 00 / B 27 108,109,110,111 ET636,ET637,ET638,ET639

ETC 1 B 30.1A Panel 00 / B 28 112,113,114,115 ET512,ET513,ET514,ET515

ETC 1 B 30.1J Panel 00 / B 29 116,117,118,119 ET516,ET517,ET518,ET519

ETC 1 B 30.1R Panel 00 / B 30 120,121,122,123 ET520,ET521,ET522,ET523

ETC 1 B 30.1Z Panel 00 / B 31 124,125,126,127 ET524,ET525,ET526,ET527

ETC 1 B 31.1A Panel 00 / B 32 128,129,130,131 ET528,ET529,ET530,ET531

ETC 1 B 31.1J Panel 00 / B 33 132,133,134,135 ET532,ET533,ET534,ET535

ETC 1 B 31.1R Panel 00 / B 34 136,137,138,139 ET536,ET537,ET538,ET539

ETC 1 B 31.1Z Panel 00 / B 35 140,141,142,143 ET540,ET541,ET542,ET543

ETC 1 B 32.1A Panel 00 / B 36 144,145,146,147 ET544,ET545,ET546,ET547

ETC 1 B 32.1J Panel 00 / B 37 148,149,150,151 ET548,ET549,ET550,ET551

ETC 1 B 32.1R Panel 00 / B 38 152,153,154,155 ET552,ET553,ET554,ET555

ETC 1 B 32.1Z Panel 00 / B 39 156,157,158,159 ET556,ET557,ET558,ET559

ETC 1 B 33.1A Panel 00 / B 40 160,161,162,163 ET560,ET561,ET562,ET563

ETC 1 B 33.1J Panel 00 / B 41 164,165,166,167 ET564,ET565,ET566,ET567

ETC 1 B 33.1R Panel 00 / B 42 168,169,170,171 ET568,ET569,ET570,ET571

ETC 1 B 33.1Z Panel 00 / B 43 172,173,174,175 ET572,ET573,ET574,ET575

ETC 1 B 34.1A Panel 00 / B 44 176,177,178,179 ET576,ET577,ET578,ET579

ETC 1 B 34.1J Panel 00 / B 45 180,181,182,183 ET580,ET581,ET582,ET583

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 24 Balanced panels in first deliveries (Cont.)

Page 48: ET

48 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

ETC 1 B 34.1R Panel 00 / B 46 184,185,186,187 ET584,ET585,ET586,ET587

ETC 1 B 34.1Z Panel 00 / B 47 188,189,190,191 ET588,ET589,ET590,ET591

ETC 1 B 35.1A Panel 00 / B 48 192,193,194,195 ET592,ET593,ET594,ET595

ETC 1 B 35.1J Panel 00 / B 49 196,197,198,199 ET596,ET597,ET598,ET599

ETC 1 B 35.1R Panel 00 / B 50 200,201,202,203 ET600,ET601,ET602,ET603

ETC 1 B 35.1Z Panel 00 / B 51 204,205,206,207 ET604,ET605,ET606,ET607

ETC 1 B 36.1A Panel 00 / B 52 208,209,210,211 ET608,ET609,ET610,ET611

ETC 1 B 36.1J Panel 00 / B 53 212,213,214,215 ET612,ET613,ET614,ET615

ETC 1 B 36.1R Panel 00 / B 54 216,217,218,219 ET616,ET617,ET618,ET619

ETC 1 B 36.1Z Panel 00 / B 55 220,221,222,223 ET620,ET621,ET622,ET623

GTIC 0 B 10.1A Panel 00 / B 56 224,225,226,227 ET1392,ET1393,ET1394,ET1395

GTIC 0 B 10.1J Panel 00 / B 57 228,229,230,231 ET1396,ET1397,ET1398,ET1399

GTIC 0 B 10.1R Panel 00 / B 58 232,233,234,235 ET1400,ET1401,ET1402,ET1403

GTIC 0 B 10.1Z Panel 00 / B 59 236,237,238,239 ET1404,ET1405,ET1406,ET1407

GTIC 0 B 11.1A Panel 00 / B 60 240,241,242,243 ET1280,ET1281,ET1282,ET1283

GTIC 0 B 11.1J Panel 00 / B 61 244,245,246,247 ET1284,ET1285,ET1286,ET1287

GTIC 0 B 11.1R Panel 00 / B 62 248,249,250,251 ET1288,ET1289,ET1290,ET1291

GTIC 0 B 11.1Z Panel 00 / B 63 252,253,254,255 ET1292,ET1293,ET1294,ET1295

GTIC 1 B 10.1A Panel 01 / B 00 00,01,02,03 ET1920,ET1921,ET1922,ET1923

GTIC 1 B 10.1J Panel 01 / B 01 04,05,06,07 ET1924,ET1925,ET1926,ET1927

GTIC 1 B 10.1R Panel 01 / B 02 08,09,10,11 ET1928,ET1929,ET1930,ET1931

GTIC 1 B 10.1Z Panel 01 / B 03 12,13,14,15 ET1932,ET1933,ET1934,ET1935

GTIC 1 B 11.1A Panel 01 / B 04 16,17,18,19 ET1936,ET1937,ET1938,ET1939

GTIC 1 B 11.1J Panel 01 / B 05 20,21,22,23 ET1940,ET1941,ET1942,ET1943

GTIC 1 B 11.1R Panel 01 / B 06 24,25,26,27 ET1944,ET1945,ET1946,ET1947

GTIC 1 B 11.1Z Panel 01 / B 07 28,29,30,31 ET1948,ET1949,ET1950,ET1951

GTIC 1 B 12.1A Panel 01 / B 08 32,33,34,35 ET1952,ET1953,ET1954,ET1955

GTIC 1 B 12.1J Panel 01 / B 09 36,37,38,39 ET1956,ET1957,ET1958,ET1959

GTIC 1 B 12.1R Panel 01 / B 10 40,41,42,43 ET1960,ET1961,ET1962,ET1963

GTIC 1 B 12.1Z Panel 01 / B 11 44,45,46,47 ET1964,ET1965,ET1966,ET1967

GTIC 1 B 13.1A Panel 02 / B 00 00,01,02,03 ET1968,ET1969,ET1970,ET1971

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 24 Balanced panels in first deliveries (Cont.)

Page 49: ET

DN70617303Issue 1-0

49

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

GTIC 1 B 13.1J Panel 02 / B 01 04,05,06,07 ET1972,ET1973,ET1974,ET1975

GTIC 1 B 13.1R Panel 02 / B 02 08,09,10,11 ET1976,ET1977,ET1978,ET1979

GTIC 1 B 13.1Z Panel 02 / B 03 12,13,14,15 ET1980,ET1981,ET1982,ET1983

GTIC 1 B 14.1A Panel 02 / B 04 16,17,18,19 ET1984,ET1985,ET1986,ET1987

GTIC 1 B 14.1J Panel 02 / B 05 20,21,22,23 ET1988,ET1989,ET1990,ET1991

GTIC 1 B 14.1R Panel 02 / B 06 24,25,26,27 ET1992,ET1993,ET1994,ET1995

GTIC 1 B 14.1Z Panel 02 / B 07 28,29,30,31 ET1996,ET1997,ET1998,ET1999

GTIC 1 B 15.1A Panel 02 / B 08 32,33,34,35 ET2000,ET2001,ET2002,ET2003

GTIC 1 B 15.1J Panel 02 / B 09 36,37,38,39 ET2004,ET2005,ET2006,ET2007

GTIC 1 B 15.1R Panel 02 / B 10 40,41,42,43 ET2008,ET2009,ET2010,ET2011

GTIC 1 B 15.1Z Panel 02 / B 11 44,45,46,47 ET2012,ET2013,ET2014,ET2015

GTIC 1 B 16.1A Panel 03 / B 00 00,01,02,03 ET2016,ET2017,ET2018,ET2019

GTIC 1 B 16.1J Panel 03 / B 01 04,05,06,07 ET2020,ET2021,ET2022,ET2023

GTIC 1 B 16.1R Panel 03 / B 02 08,09,10,11 ET2024,ET2025,ET2026,ET2027

GTIC 1 B 16.1Z Panel 03 / B 03 12,13,14,15 ET2028,ET2029,ET2030,ET2031

GTIC 1 B 17.1A Panel 03 / B 04 16,17,18,19 ET2032,ET2033,ET2034,ET2035

GTIC 1 B 17.1J Panel 03 / B 05 20,21,22,23 ET2036,ET2037,ET2038,ET2039

GTIC 1 B 17.1R Panel 03 / B 06 24,25,26,27 ET2040,ET2041,ET2042,ET2043

GTIC 1 B 17.1Z Panel 03 / B 07 28,29,30,31 ET2044,ET2045,ET2046,ET2047

ETC 2 B 19.1A Panel 03 / B 08 32,33,34,35 ET1136,ET1137,ET1138,ET1139

ETC 2 B 19.1J Panel 03 / B 09 36,37,38,39 ET1140,ET1141,ET1142,ET1143

ETC 2 B 19.1R Panel 03 / B 10 40,41,42,43 ET1140,ET1141,ET1142,ET1143

ETC 2 B 19.1Z Panel 03 / B 11 44,45,46,47 ET1140,ET1141,ET1142,ET1143

ETC 2 B 20.1A Panel 04 / B 00 00,01,02,03 ET1024,ET1025,ET1026,ET1027

ETC 2 B 20.1J Panel 04 / B 01 04,05,06,07 ET1028,ET1029,ET1030,ET1031

ETC 2 B 20.1R Panel 04 / B 02 08,09,10,11 ET1032,ET1033,ET1034,ET1035

ETC 2 B 20.1Z Panel 04 / B 03 12,13,14,15 ET1036,ET1037,ET1038,ET1039

ETC 2 B 21.1A Panel 04 / B 04 16,17,18,19 ET1040,ET1041,ET1042,ET1043

ETC 2 B 21.1J Panel 04 / B 05 20,21,22,23 ET1044,ET1045,ET1046,ET1047

ETC 2 B 21.1R Panel 04 / B 06 24,25,26,27 ET1048,ET1049,ET1050,ET1051

ETC 2 B 21.1Z Panel 04 / B 07 28,29,30,31 ET1052,ET1053,ET1054,ET1055

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 24 Balanced panels in first deliveries (Cont.)

Page 50: ET

50 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

ETC 2 B 22.1A Panel 04 / B 08 32,33,34,35 ET1056,ET1057,ET1058,ET1059

ETC 2 B 22.1J Panel 04 / B 09 36,37,38,39 ET1060,ET1061,ET1062,ET1063

ETC 2 B 22.1R Panel 04 / B 10 40,41,42,43 ET1064,ET1065,ET1066,ET1067

ETC 2 B 22.1Z Panel 04 / B 11 44,45,46,47 ET1068,ET1069,ET1070,ET1071

ETC 2 B 23.1A Panel 04 / B 12 48,49,50,51 ET1072,ET1073,ET1074,ET1075

ETC 2 B 23.1J Panel 04 / B 13 52,53,54,55 ET1076,ET1077,ET1078,ET1079

ETC 2 B 23.1R Panel 04 / B 14 56,57,58,59 ET1080,ET1081,ET1082,ET1083

ETC 2 B 23.1Z Panel 04 / B 15 60,61,62,63 ET1084,ET1085,ET1086,ET1087

ETC 2 B 24.1A Panel 04 / B 16 64,65,66,67 ET1088,ET1089,ET1090,ET1091

ETC 2 B 24.1J Panel 04 / B 17 68,69,70,71 ET1092,ET1093,ET1094,ET1095

ETC 2 B 24.1R Panel 04 / B 18 72,73,74,75 ET1096,ET1097,ET1098,ET1099

ETC 2 B 24.1Z Panel 04 / B 19 76,77,78,79 ET1100,ET1101,ET1102,ET1103

ETC 2 B 25.1A Panel 04 / B 20 80,81,82,83 ET1104,ET1105,ET1106,ET1107

ETC 2 B 25.1J Panel 04 / B 21 84,85,86,87 ET1108,ET1109,ET1110,ET1111

ETC 2 B 25.1R Panel 04 / B 22 88,89,90,91 ET1112,ET1113,ET1114,ET1115

ETC 2 B 25.1Z Panel 04 / B 23 92,93,94,95 ET1116,ET1117,ET1118,ET1119

ETC 2 B 26.1A Panel 04 / B 24 96,97,98,99 ET1120,ET1121,ET1122,ET1123

ETC 2 B 26.1J Panel 04 / B 25 100,101,102,103 ET1124,ET1125,ET1126,ET1127

ETC 2 B 26.1R Panel 04 / B 26 104,105,106,107 ET1128,ET1129,ET1130,ET1131

ETC 2 B 26.1Z Panel 04 / B 27 108,109,110,111 ET1132,ET1133,ET1134,ET1135

ETC 3 B 28.1A Panel 04 / B 28 112,113,114,115 ET896,ET897,ET898,ET899

ETC 3 B 28.1J Panel 04 / B 29 116,117,118,119 ET900,ET901,ET902,ET903

ETC 3 B 28.1R Panel 04 / B 30 120,121,122,123 ET904,ET905,ET906,ET907

ETC 3 B 28.1Z Panel 04 / B 31 124,125,126,127 ET908,ET909,ET910,ET911

ETC 3 B 29.1A Panel 04 / B 32 128,129,130,131 ET880,ET881,ET882,ET883

ETC 3 B 29.1J Panel 04 / B 33 132,133,134,135 ET884,ET885,ET886,ET887

ETC 3 B 29.1R Panel 04 / B 34 136,137,138,139 ET888,ET889,ET890,ET891

ETC 3 B 29.1Z Panel 04 / B 35 140,141,142,143 ET892,ET893,ET894,ET895

ETC 3 B 30.1A Panel 04 / B 36 144,145,146,147 ET768,ET769,ET770,ET771

ETC 3 B 30.1J Panel 04 / B 37 148,149,150,151 ET772,ET773,ET774,ET775

ETC 3 B 30.1R Panel 04 / B 38 152,153,154,155 ET776,ET777,ET778,ET779

ETC 3 B 30.1Z Panel 04 / B 39 156,157,158,159 ET780,ET781,ET782,ET783

ETC 3 B 31.1A Panel 04 / B 40 160,161,162,163 ET784,ET785,ET786,ET787

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 24 Balanced panels in first deliveries (Cont.)

Page 51: ET

DN70617303Issue 1-0

51

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

ETC 3 B 31.1J Panel 04 / B 41 164,165,166,167 ET788,ET789,ET790,ET791

ETC 3 B 31.1R Panel 04 / B 42 168,169,170,171 ET792,ET793,ET794,ET795

ETC 3 B 31.1Z Panel 04 / B 43 172,173,174,175 ET796,ET797,ET798,ET799

ETC 3 B 32.1A Panel 04 / B 44 176,177,178,179 ET800,ET801,ET802,ET803

ETC 3 B 32.1J Panel 04 / B 45 180,181,182,183 ET804,ET805,ET806,ET807

ETC 3 B 32.1R Panel 04 / B 46 184,185,186,187 ET808,ET809,ET810,ET811

ETC 3 B 32.1Z Panel 04 / B 47 188,189,190,191 ET812,ET813,ET814,ET815

ETC 3 B 33.1A Panel 04 / B 48 192,193,194,195 ET816,ET817,ET818,ET819

ETC 3 B 33.1J Panel 04 / B 49 196,197,198,199 ET820,ET821,ET822,ET823

ETC 3 B 33.1R Panel 04 / B 50 200,201,202,203 ET824,ET825,ET826,ET827

ETC 3 B 33.1Z Panel 04 / B 51 204,205,206,207 ET828,ET829,ET830,ET831

ETC 3 B 34.1A Panel 04 / B 52 208,209,210,211 ET832,ET833,ET834,ET835

ETC 3 B 34.1J Panel 04 / B 53 212,213,214,215 ET836,ET837,ET838,ET839

ETC 3 B 34.1R Panel 04 / B 54 216,217,218,219 ET840,ET841,ET842,ET843

ETC 3 B 34.1Z Panel 04 / B 55 220,221,222,223 ET844,ET845,ET846,ET847

ETC 3 B 35.1A Panel 04 / B 56 224,225,226,227 ET848,ET849,ET850,ET851

ETC 3 B 35.1J Panel 04 / B 57 228,229,230,231 ET852,ET853,ET854,ET855

ETC 3 B 35.1R Panel 04 / B 58 232,233,234,235 ET856,ET857,ET858,ET859

ETC 3 B 35.1Z Panel 04 / B 59 236,237,238,239 ET860,ET861,ET862,ET863

ETC 3 B 36.1A Panel 04 / B 60 240,241,242,243 ET864,ET865,ET866,ET867

ETC 3 B 36.1J Panel 04 / B 61 244,245,246,247 ET868,ET869,ET870,ET871

ETC 3 B 36.1R Panel 04 / B 62 248,249,250,251 ET872,ET873,ET874,ET875

ETC 3 B 36.1Z Panel 04 / B 63 252,253,254,255 ET876,ET877,ET878,ET879

GTIC 0 B 12.1A Panel T00 / B 00 00,01,02,03 ET1296,ET1297,ET1298,ET1299

GTIC 0 B 12.1J Panel T00 / B 01 04,05,06,07 ET1300,ET1301,ET1302,ET1303

GTIC 0 B 12.1R Panel T00 / B 02 08,09,10,11 ET1304,ET1305,ET1306,ET1307

GTIC 0 B 12.1Z Panel T00 / B 03 12,13,14,15 ET1308,ET1309,ET1310,ET1311

GTIC 0 B 13.1A Panel T00 / B 04 16,17,18,19 ET1312,ET1313,ET1314,ET1315

GTIC 0 B 13.1J Panel T00 / B 05 20,21,22,23 ET1316,ET1317,ET1318,ET1319

GTIC 0 B 13.1R Panel T00 / B 06 24,25,26,27 ET1320,ET1321,ET1322,ET1323

GTIC 0 B 13.1Z Panel T00 / B 07 28,29,30,31 ET1324,ET1325,ET1326,ET1327

GTIC 0 B 14.1A Panel T00 / B 08 32,33,34,35 ET1328,ET1329,ET1330,ET1331

GTIC 0 B 14.1J Panel T00 / B 09 36,37,38,39 ET1332,ET1333,ET1334,ET1335

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 24 Balanced panels in first deliveries (Cont.)

Page 52: ET

52 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

The equipping order of the connector panels in the cabling cabinet in upgrade deliveries is presented in the following table.

GTIC 0 B 14.1R Panel T00 / B 10 40,41,42,43 ET1336,ET1337,ET1338,ET1339

GTIC 0 B 14.1Z Panel T00 / B 11 44,45,46,47 ET1340,ET1341,ET1342,ET1343

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 24 Balanced panels in first deliveries (Cont.)

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

ETC 0 B 04.1A Panel 04 / B 61 244,245,246,247 ET560,ET561,ET562,ET563

ETC 0 B 04.1J Panel 04 / B 62 248,249,250,251 ET564,ET565,ET566,ET567

ETC 0 B 04.1R Panel 04 / B 63 252,253,254,255 ET568,ET569,ET570,ET571

ETC 0 B 04.1Z Panel 04 / B 58 232,233,234,235 ET572,ET573,ET574,ET575

ETC 1 B 01.1A Panel 04 / B 59 236,237,238,239 ET576,ET577,ET578,ET579

ETC 1 B 01.1J Panel 04 / B 60 240,241,242,243 ET580,ET581,ET582,ET583

ETC 1 B 01.1R Panel 04 / B 55 220,221,222,223 ET584,ET585,ET586,ET587

ETC 1 B 01.1Z Panel 04 / B 56 224,225,226,227 ET588,ET589,ET590,ET591

ETC 1 B 02.1A Panel 04 / B 57 228,229,230,231 ET592,ET593,ET594,ET595

ETC 1 B 02.1J Panel 04 / B 52 208,209,210,211 ET596,ET597,ET598,ET599

ETC 1 B 02.1R Panel 04 / B 53 212,213,214,215 ET600,ET601,ET602,ET603

ETC 1 B 02.1Z Panel 04 / B 54 216,217,218,219 ET604,ET605,ET606,ET607

ETC 1 B 03.1A Panel 04 / B 49 196,197,198,199 ET608,ET609,ET610,ET611

ETC 1 B 03.1J Panel 04 / B 50 200,201,202,203 ET612,ET613,ET614,ET615

ETC 1 B 03.1R Panel 04 / B 51 204,205,206,207 ET616,ET617,ET618,ET619

ETC 1 B 03.1Z Panel 04 / B 47 188,189,190,191 ET620,ET621,ET622,ET623

ETC 1 B 04.1A Panel 04 / B 48 192,193,194,195 ET624,ET625,ET626,ET627

ETC 1 B 04.1J Panel 04 / B 44 176,177,178,179 ET628,ET629,ET630,ET631

ETC 1 B 04.1R Panel 04 / B 45 180,181,182,183 ET632,ET633,ET634,ET635

ETC 1 B 04.1Z Panel 04 / B 46 184,185,186,187 ET636,ET637,ET638,ET639

GTIC 0 / ETC 5

B 01.1A (GTIC 0) / B03.1A (ETC 5) Panel 04 / B 41 164,165,166,167 ET904,ET905,ET906,ET907

GTIC 0 / ETC 5

B 01.1J (GTIC 0) / B03.1J (ETC 5) Panel 04 / B 42 168,169,170,171 ET908,ET909,ET910,ET911

GTIC 0 / ETC 5

B 01.1R (GTIC 0) / B03.1R (ETC 5) Panel 04 / B 43 172,173,174,175 ET912,ET913,ET914,ET915

Table 25 Balanced panels in upgrade deliveries

Page 53: ET

DN70617303Issue 1-0

53

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

GTIC 0 / ETC 5

B 01.1Z (GTIC 0) / B03.1Z (ETC 5) Panel 04 / B 38 152,153,154,155 ET916,ET917,ET918,ET919

GTIC 0 / ETC 5

B 02.1A (GTIC 0) / B04.1A (ETC 5) Panel 04 / B 39 156,157,158,159 ET920,ET921,ET922,ET923

GTIC 0 / ETC 5

B 02.1J (GTIC 0) / B04.1J (ETC 5) Panel 04 / B 40 160,161,162,163 ET924,ET925,ET926,ET927

GTIC 0 / ETC 5

B 02.1R (GTIC 0) / B04.1R (ETC 5) Panel 04 / B 35 140,141,142,143 ET928,ET929,ET930,ET931

GTIC 0 / ETC 5

B 02.1Z (GTIC 0) / B04.1Z (ETC 5) Panel 04 / B 36 144,145,146,147 ET932,ET933,ET934,ET935

GTIC 0 / ETC 5

B 03.1A (GTIC 0) / B05.1A (ETC 5) Panel 04 / B 37 148,149,150,151 ET936,ET937,ET938,ET939

GTIC 0 / ETC 5

B 03.1J (GTIC 0) / B05.1J (ETC 5) Panel 04 / B 32 128,129,130,131 ET940,ET941,ET942,ET943

GTIC 0 / ETC 5

B 03.1R (GTIC 0) / B05.1R (ETC 5) Panel 04 / B 33 132,133,134,135 ET944,ET945,ET946,ET947

GTIC 0 / ETC 5

B 03.1Z (GTIC 0) / B05.1Z (ETC 5) Panel 04 / B 34 136,137,138,139 ET948,ET949,ET950,ET951

GTIC 0 / ETC 5

B 04.1A (GTIC 0) / B06.1A (ETC 5) Panel 04 / B 29 116,117,118,119 ET816,ET817,ET818,ET819

GTIC 0 / ETC 5

B 04.1J (GTIC 0) / B06.1J (ETC 5) Panel 04 / B 30 120,121,122,123 ET820,ET821,ET822,ET823

GTIC 0 / ETC 5

B 04.1R (GTIC 0) / B06.1R (ETC 5) Panel 04 / B 31 124,125,126,127 ET824,ET825,ET826,ET827

GTIC 0 / ETC 5

B 04.1Z (GTIC 0) / B06.1Z (ETC 5) Panel 04 / B 26 104,105,106,107 ET828,ET829,ER830,ET831

GTIC 0 / ETC 5

B 05.1A (GTIC 0) / B07.1A (ETC 5) Panel 04 / B 27 108,109,110,111

ET1072,ET1073,ET1074,ET1075

GTIC 0 / ETC 5

B 05.1J (GTIC 0) / B07.1J (ETC 5) Panel 04 / B 28 112,113,114,115

ET1076,ET1077,ET1078,ET1079

GTIC 0 / ETC 5

B 05.1R (GTIC 0) / B07.1R (ETC 5) Panel 04 / B 23 92,93,94,95

ET1080,ET1081,ET1082,ET1083

GTIC 0 / ETC 5

B 05.1Z (GTIC 0) / B07.1Z (ETC 5) Panel 04 / B 24 96,97,98,99

ET1084,ET1085,ET1086,ET1087

GTIC 0 / ETC 5

B 06.1A (GTIC 0) / B08.1A (ETC 5) Panel 04 / B 25 100,101,102,103

ET1328,ET1329,ET1330,ET1331

GTIC 0 / ETC 5

B 06.1J (GTIC 0) / B08.1J (ETC 5) Panel 04 / B 20 80,81,82,83

ET1332,ET1333,ET1334,ET1335

GTIC 0 / ETC 5

B 06.1R (GTIC 0) / B08.1R (ETC 5) Panel 04 / B 21 84,85,86,87

ET1336,ET1337,ET1338,ET1339

GTIC 0 / ETC 5

B 06.1Z (GTIC 0) / B08.1Z (ETC 5) Panel 04 / B 22 88,89,90,91

ET1340,ET1341,ET1342,ET1343

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 25 Balanced panels in upgrade deliveries (Cont.)

Page 54: ET

54 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

GTIC 0 B 07.1A Panel 04 / B 17 68,69,70,71ET1792,ET1793,ET1794,ET1795

GTIC 0 B 07.1J Panel 04 / B 18 72,73,74,75ET1796,ET1797,ET1798,ET1799

GTIC 0 B 07.1R Panel 04 / B 19 76,77,78,79ET1800,ET1801,ET1802,ET1803

GTIC 0 B 07.1Z Panel 04 / B 15 60,61,62,63ET1804,ET1805,ET1806,ET1807

GTIC 0 B 08.1A Panel 04 / B 16 64,65,66,67ET1808,ET1809,ET1810,ET1811

GTIC 0 B 08.1J Panel 04 / B 12 48,49,50,51ET1812,ET1813,ET1814,ET1815

GTIC 0 B 08.1R Panel 04 / B 13 52,53,54,55ET1816,ET1817,ET1818,ET1819

GTIC 0 B 08.1Z Panel 04 / B 14 56,57,58,59ET1820,ET1821,ET1822,ET1823

GTIC 1 B 01.1A Panel 04 / B 09 36,37,38,39ET1408,ET1409,ET1410,ET1411

GTIC 1 B 01.1J Panel 04 / B 10 40,41,42,43ET1412,ET1413,ET1414,ET1415

GTIC 1 B 01.1R Panel 04 / B 11 44,45,46,47ET1416,ET1417,ET1418,ET1419

GTIC 1 B 01.1Z Panel 04 / B 06 24,25,26,27ET1420,ET1421,ET1422,ET1423

GTIC 1 B 02.1A Panel 04 / B 07 28,29,30,31ET1424,ET1425,ET1426,ET1427

GTIC 1 B 02.1J Panel 04 / B 08 32,33,34,35ET1428,ET1429,ET1430,ET1431

GTIC 1 B 02.1R Panel 04 / B 03 12,13,14,15ET1432,ET1433,ET1434,ET1435

GTIC 1 B 02.1Z Panel 04 / B 04 16,17,18,19ET1436,ET1437,ET1438,ET1439

GTIC 1 B 03.1A Panel 04 / B 05 20,21,22,23ET1440,ET1441,ET1442,ET1443

GTIC 1 B 03.1J Panel 04 / B 00 00,01,02,03ET1444,ET1445,ET1446,ET1447

GTIC 1 B 03.1R Panel 04 / B 01 04,05,06,07ET1448,ET1449,ET1450,ET1451

GTIC 1 B 03.1Z Panel 04 / B 02 08,09,10,11ET1452,ET1453,ET1454,ET1455

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 25 Balanced panels in upgrade deliveries (Cont.)

Page 55: ET

DN70617303Issue 1-0

55

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

GTIC 1 B 04.1A Panel 03 / B 09 36,37,38,39ET1456,ET1457,ET1458,ET1459

GTIC 1 B 04.1J Panel 03 / B 10 40,41,42,43ET1460,ET1461,ET1462,ET1463

GTIC 1 B 04.1R Panel 03 / B 11 44,45,46,47ET1464,ET1465,ET1466,ET1467

GTIC 1 B 04.1Z Panel 03 / B 06 24,25,26,27ET1468,ET1469,ET1470,ET1471

GTIC 1 B 05.1A Panel 03 / B 07 28,29,30,31ET1472,ET1473,ET1474,ET1475

GTIC 1 B 05.1J Panel 03 / B 08 32,33,34,35ET1476,ET1477,ET1478,ET1479

GTIC 1 B 05.1R Panel 03 / B 03 12,13,14,15ET1480,ET1481,ET1482,ET1483

GTIC 1 B 05.1Z Panel 03 / B 04 16,17,18,19ET1484,ET1485,ET1486,ET1487

GTIC 1 B 06.1A Panel 03 / B 05 20,21,22,23ET1488,ET1489,ET1490,ET1491

GTIC 1 B 06.1J Panel 03 / B 00 00,01,02,03ET1492,ET1493,ET1494,ET1495

GTIC 1 B 06.1R Panel 03 / B 01 04,05,06,07ET1496,ET1497,ET1498,ET1499

GTIC 1 B 06.1Z Panel 03 / B 02 08,09,10,11ET1500,ET1501,ET1502,ET1503

GTIC 1 B 07.1A Panel 02 / B 09 36,37,38,39ET1504,ET1505,ET1506,ET1507

GTIC 1 B 07.1J Panel 02 / B 10 40,41,42,43ET1508,ET1509,ET1510,ET1511

GTIC 1 B 07.1R Panel 02 / B 11 44,45,46,47ET1512,ET1513,ET1514,ET1515

GTIC 1 B 07.1Z Panel 02 / B 06 24,25,26,27ET1516,ET1517,ET1518,ET1519

GTIC 1 B 08.1A Panel 02 / B 07 28,29,30,31ET1520,ET1521,ET1522,ET1523

GTIC 1 B 08.1J Panel 02 / B 08 32,33,34,35ET1524,ET1525,ET1526,ET1527

GTIC 1 B 08.1R Panel 02 / B 03 12,13,14,15ET1528,ET1529,ET1530,ET1531

GTIC 1 B 08.1Z Panel 02 / B 04 16,17,18,19ET1532,ET1533,ET1534,ET1535

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 25 Balanced panels in upgrade deliveries (Cont.)

Page 56: ET

56 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

ETC 2 B 01.1A Panel 02 / B 05 20,21,22,23ET1344,ET1345,ET1346,ET1347

ETC 2 B 01.1J Panel 02 / B 00 00,01,02,03ET1348,ET1349,ET1350,ET1351

ETC 2 B 01.1R Panel 02 / B 01 04,05,06,07ET1352,ET1353,ET1354,ET1355

ETC 2 B 01.1Z Panel 02 / B 02 08,09,10,11ET1356,ET1357,ET1358,ET1359

ETC 2 B 02.1A Panel 01 / B 09 36,37,38,39ET1360,ET1361,ET1362,ET1363

ETC 2 B 02.1J Panel 01 / B 10 40,41,42,43ET1364,ET1365,ET1366,ET1367

ETC 2 B 02.1R Panel 01 / B 11 44,45,46,47ET1368,ET1369,ET1370,ET1371

ETC 2 B 02.1Z Panel 01 / B 06 24,25,26,27ET1372,ET1373,ET1374,ET1375

ETC 2 B 03.1A Panel 01 / B 07 28,29,30,31ET1376,ET1377,ET1378,ET1379

ETC 2 B 03.1J Panel 01 / B 08 32,33,34,35ET1380,ET1381,ET1382,ET1383

ETC 2 B 03.1R Panel 01 / B 03 12,13,14,15ET1384,ET1385,ET1386,ET1387

ETC 2 B 03.1Z Panel 01 / B 04 16,17,18,19ET1388,ET1389,ET1390,ET1391

ETC 2 B 04.1A Panel 01 / B 05 20,21,22,23ET1392,ET1393,ET1394,ET1395

ETC 2 B 04.1J Panel 01 / B 00 00,01,02,03ET1396,ET1397,ET1398,ET1399

ETC 2 B 04.1R Panel 01 / B 01 04,05,06,07ET1400,ET1401,ET1402,ET1403

ETC 2 B 04.1Z Panel 01 / B 02 08,09,10,11ET1404,ET1405,ET1406,ET1407

ETC 2 B 05.1A Panel 00 / B 61 244,245,246,247ET1600,ET1601,ET1602,ET1603

ETC 2 B 05.1J Panel 00 / B 62 248,249,250,251ET1604,ET1605,ET1606,ET1607

ETC 2 B 05.1R Panel 00 / B 63 252,253,254,255ET1608,ET1609,ET1610,ET1611

ETC 2 B 05.1Z Panel 00 / B 58 232,233,234,235ET1612,ET1613,ET1614,ET1615

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 25 Balanced panels in upgrade deliveries (Cont.)

Page 57: ET

DN70617303Issue 1-0

57

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

ETC 2 B 06.1A Panel 00 / B 59 236,237,238,239ET1616,ET1617,ET1618,ET1619

ETC 2 B 06.1J Panel 00 / B 60 240,241,242,243ET1620,ET1621,ET1622,ET1623

ETC 2 B 06.1R Panel 00 / B 55 220,221,222,223ET1624,ET1625,ET1626,ET1627

ETC 2 B 06.1Z Panel 00 / B 56 224,225,226,227ET1628,ET1629,ET1630,ET1631

ETC 2 B 07.1A Panel 00 / B 57 228,229,230,231ET1632,ET1633,ET1634,ET1635

ETC 2 B 07.1J Panel 00 / B 52 208,209,210,211ET1636,ET1637,ET1638,ET1639

ETC 2 B 07.1R Panel 00 / B 53 212,213,214,215ET1640,ET1641,ET1642,ET1643

ETC 2 B 07.1Z Panel 00 / B 54 216,217,218,219ET1644,ET1645,ET1646,ET1647

ETC 2 B 08.1A Panel 00 / B 49 196,197,198,199ET1648,ET1649,ET1650,ET1651

ETC 2 B 08.1J Panel 00 / B 50 200,201,202,203ET1652,ET1653,ET1654,ET1655

ETC 2 B 08.1R Panel 00 / B 51 204,205,206,207ET1656,ET1657,ET1658,ET1659

ETC 2 B 08.1Z Panel 00 / B 47 188,189,190,191ET1660,ET1661,ET1662,ET1663

ETC 3 B 01.1A Panel 00 / B 48 192,193,194,195ET1664,ET1665,ET1666,ET1667

ETC 3 B 01.1J Panel 00 / B 44 176,177,178,179ET1668,ET1669,ET1670,ET1671

ETC 3 B 01.1R Panel 00 / B 45 180,181,182,183ET1672,ET1673,ET1674,ET1675

ETC 3 B 01.1Z Panel 00 / B 46 184,185,186,187ET1676,ET1677,ET1678,ET1679

ETC 3 B 02.1A Panel 00 / B 41 164,165,166,167ET1680,ET1681,ET1682,ET1683

ETC 3 B 02.1J Panel 00 / B 42 168,169,170,171ET1684,ET1685,ET1686,ET1687

ETC 3 B 02.1R Panel 00 / B 43 172,173,174,175ET1688,ET1689,ET1690,ET1691

ETC 3 B 02.1Z Panel 00 / B 38 152,153,154,155ET1692,ET1693,ET1694,ET1695

ETC 3 B 03.1A Panel 00 / B 39 156,157,158,159ET1696,ET1697,ET1698,ET1699

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 25 Balanced panels in upgrade deliveries (Cont.)

Page 58: ET

58 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

ETC 3 B 03.1J Panel 00 / B 40 160,161,162,163ET1700,ET1701,ET1702,ET1703

ETC 3 B 03.1R Panel 00 / B 35 140,141,142,143ET1704,ET1705,ET1706,ET1707

ETC 3 B 03.1Z Panel 00 / B 36 144,145,146,147ET1708,ET1709,ET1710,ET1711

ETC 3 B 04.1A Panel 00 / B 37 148,149,150,151ET1712,ET1713,ET1714,ET1715

ETC 3 B 04.1J Panel 00 / B 32 128,129,130,131ET1716,ET1717,ET1718,ET1719

ETC 3 B 04.1R Panel 00 / B 33 132,133,134,135ET1720,ET1721,ET1722,ET1723

ETC 3 B 04.1Z Panel 00 / B 34 136,137,138,139ET1724,ET1725,ET1726,ET1727

ETC 3 B 05.1A Panel 00 / B 29 116,117,118,119ET1728,ET1729,ET1730,ET1731

ETC 3 B 05.1J Panel 00 / B 30 120,121,122,123ET1732,ET1733,ET1734,ET1735

ETC 3 B 05.1R Panel 00 / B 31 124,125,126,127ET1736,ET1737,ET1738,ET1739

ETC 3 B 05.1Z Panel 00 / B 26 104,105,106,107ET1740,ET1741,ET1742,ET1743

ETC 3 B 06.1A Panel 00 / B 27 108,109,110,111ET1744,ET1745,ET1746,ET1747

ETC 3 B 06.1J Panel 00 / B 28 112,113,114,115ET1748,ET1749,ET1750,ET1751

ETC 3 B 06.1R Panel 00 / B 23 92,93,94,95ET1752,ET1753,ET1754,ET1755

ETC 3 B 06.1Z Panel 00 / B 24 96,97,98,99ET1756,ET1757,ET1758,ET1759

ETC 3 B 07.1A Panel 00 / B 25 100,101,102,103ET1760,ET1761,ET1762,ET1763

ETC 3 B 07.1J Panel 00 / B 20 80,81,82,83ET1764,ET1765,ET1766,ET1767

ETC 3 B 07.1R Panel 00 / B 21 84,85,86,87ET1768,ET1769,ET1770,ET1771

ETC 3 B 07.1Z Panel 00 / B 22 88,89,90,91ET1772,ET1773,ET1774,ET1775

ETC 3 B 08.1A Panel 00 / B 17 68,69,70,71ET1776,ET1777,ET1778,ET1779

ETC 3 B 08.1J Panel 00 / B 18 72,73,74,75ET1780,ET1781,ET1782,ET1783

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 25 Balanced panels in upgrade deliveries (Cont.)

Page 59: ET

DN70617303Issue 1-0

59

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

4.3 TCSM3iTwo installation options of the third-generation Transcoder Submultiplexer are available: the TCSM3i for stand-alone installation option and the TCSM3i for combined BSC/TCSM installation option. The TCSM3i for stand-alone installation option always

ETC 3 B 08.1R Panel 00 / B 19 76,77,78,79ET1784,ET1785,ET1786,ET1787

ETC 3 B 08.1Z Panel 00 / B 15 60,61,62,63ET1788,ET1789,ET1790,ET1791

ETC 4 B 01.1A Panel 00 / B 16 64,65,66,67ET1920,ET1921,ET1922,ET1923

ETC 4 B 01.1J Panel 00 / B 12 48,49,50,51ET1924,ET1925,ET1926,ET1927

ETC 4 B 01.1R Panel 00 / B 13 52,53,54,55ET1928,ET1929,ET1930,ET1931

ETC 4 B 01.1Z Panel 00 / B 14 56,57,58,59ET1932,ET1933,ET1934,ET1935

ETC 4 B 02.1A Panel 00 / B 09 36,37,38,39ET1936,ET1937,ET1938,ET1939

ETC 4 B 02.1J Panel 00 / B 10 40,41,42,43ET1940,ET1941,ET1942,ET1943

ETC 4 B 02.1R Panel 00 / B 11 44,45,46,47ET1944,ET1945,ET1946,ET1947

ETC 4 B 02.1Z Panel 00 / B 06 24,25,26,27ET1948,ET1949,ET1950,ET1951

ETC 4 B 03.1A Panel 00 / B 07 28,29,30,31ET1952,ET1953,ET1954,ET1955

ETC 4 B 03.1J Panel 00 / B 08 32,33,34,35ET1956,ET1957,ET1958,ET1959

ETC 4 B 03.1R Panel 00 / B 03 12,13,14,15ET1960,ET1961,ET1962,ET1963

ETC 4 B 03.1Z Panel 00 / B 04 16,17,18,19ET1964,ET1965,ET1966,ET1967

ETC 4 B 04.1A Panel 00 / B 05 20,21,22,23ET1968,ET1969,ET1970,ET1971

ETC 4 B 04.1J Panel 00 / B 00 00,01,02,03ET1972,ET1973,ET1974,ET1975

ETC 4 B 04.1R Panel 00 / B 01 04,05,06,07ET1976,ET1977,ET1978,ET1979

ETC 4 B 04.1Z Panel 00 / B 02 08,09,10,11ET1980,ET1981,ET1982,ET1983

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Front ports in balanced panel through this cable

Corresponding external ET numbers

Table 25 Balanced panels in upgrade deliveries (Cont.)

Page 60: ET

60 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does not have a cabling cabinet.

4.3.1 TCSM3i for stand-alone installation optionIn the TCSM3i for stand-alone installation option, the cabling cabinet is always mounted to the TCSA cabinet. Balanced cabling panel is default, whereas the unbalanced is optional and must be ordered separately.

E1/T1 (PCM) balanced trunk cable panel (CPETS-F)Two large balanced CPETS-F panels are used in the cabling cabinet mounted to the TCSA cabinet.

The cables and connectors should meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the requirements of the FCC Part 68.

Recommended cable type for T1 trunk cable (CNIS) is presented in the following table figure.

Panel number

Connector panel

0 CPETS-F

1 CPBP

2 CPBP

3 CPBP

4 CPETS-F

Table 26 Balanced connector panels for the TCSM3i

Cable type: 4 insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Filotex Milliflex3 SH G26/2x4)

Cable connector: RJ45 modular connector (8-pole)

Table 27 Recommended cable type for T1 trunk cables (CNIS)

Page 61: ET

DN70617303Issue 1-0

61

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

Figure 12 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables

Recommended cable type for E1 trunk cables (CNIA) is presented in the following table and figure.

Figure 13 RJ45 connector cable (CNIA cable type) with four connectors

Equipping orderThe cabling cabinet is always used with the TCSM3i for stand-alone installation option. The cabling cabinet and the balanced ET panels are delivered in an optional cabling cabinet set, because TCSA cabinet is a base for both TCSM3i for stand-alone installa-tion option and for TCSM3i for combined BSC/TCSM installation option.

Cable type: 4x(2x2) insulated pairs, twisted, double-shielded, cross section 0.4 mm2 (type: Milliflex3 SH G26/4)

Cable connector: RJ45 modular connector plug (8-pole)

Table 28 Recommended cable type for E1 trunk cables (CNIA)

8

MODULAR CONNECTOR

SLEEVE

CABLE

IDENTIFICATIONSTICKER

DN98339941

CONNECTOR

DN00206525

1 2 3 4

Page 62: ET

62 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

Equipping of ETs proceeds in steps. The equipping order in the cabling cabinet is pre-sented in the following table.

ETC car-tridge

From GT4C-A connector position

To panel / con-nector position

Front ports in CPETS-F panel through this cable

Front ports used for TR3 A-interface

ETC 0 B 01.1A Panel 0 / B 00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 01

ETC 0 B 01.1J Panel 0 / B 01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 02

ETC 0 B 01.1R Panel 0 / B 02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 03

ETC 0 B 01.1Z Panel 0 / B 03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 04

ETC 1 B 01.1A Panel 0 / B 04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 05

ETC 1 B 01.1J Panel 0 / B 05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 06

ETC 1 B 01.1R Panel 0 / B 06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 07

ETC 1 B 01.1Z Panel 0 / B 07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 08

ETC 2 B 01.1A Panel 0 / B 08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 09

ETC 2 B 01.1J Panel 0 / B 09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 10

ETC 2 B 01.1R Panel 0 / B 10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 11

ETC 2 B 01.1Z Panel 0 / B 11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 12

ETC 1 B 02.1A Panel 0 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 13

ETC 1 B 02.1J Panel 0 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 14

ETC 1 B 02.1R Panel 0 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 15

ETC 1 B 02.1Z Panel 0 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 16

ETC 0 B 02.1A Panel 0 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 01

ETC 0 B 02.1J Panel 0 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 02

ETC 0 B 02.1R Panel 0 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 03

ETC 0 B 02.1Z Panel 0 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 04

ETC 1 B 03.1A Panel 0 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 05

ETC 1 B 03.1J Panel 0 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 06

ETC 1 B 03.1R Panel 0 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 07

ETC 1 B 03.1Z Panel 0 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 08

ETC 2 B 02.1A Panel 0 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 09

ETC 2 B 02.1J Panel 0 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 10

ETC 2 B 02.1R Panel 0 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 11

ETC 2 B 02.1Z Panel 0 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 12

ETC 1 B 04.1A Panel 0 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 13

ETC 1 B 04.1J Panel 0 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 14

ETC 1 B 04.1R Panel 0 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 15

ETC 1 B 04.1Z Panel 0 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 16

Table 29 Balanced panels in the cabling cabinet - A-interface

Page 63: ET

DN70617303Issue 1-0

63

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

ETC 0 B 03.1A Panel 0 / B32 128, 129, 130, 131 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 01

ETC 0 B 03.1J Panel 0 / B33 132, 133, 134, 135 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 02

ETC 0 B 03.1R Panel 0 / B34 136, 137, 138, 139 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 03

ETC 0 B 03.1Z Panel 0 / B35 140, 141, 142, 143 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 04

ETC 1 B 05.1A Panel 0 / B36 144, 145, 146, 147 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 05

ETC 1 B 05.1J Panel 0 / B37 148, 149, 150, 151 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 06

ETC 1 B 05.1R Panel 0 / B38 152, 153, 154, 155 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 07

ETC 1 B 05.1Z Panel 0 / B39 156, 157, 158, 159 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 08

ETC 2 B 03.1A Panel 0 / B40 160, 161, 162, 163 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 09

ETC 2 B 03.1J Panel 0 / B41 164, 165, 166, 167 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 10

ETC 2 B 03.1R Panel 0 / B42 168, 169, 170, 171 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 11

ETC 2 B 03.1Z Panel 0 / B43 172, 173, 174, 175 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 12

ETC 1 B 06.1A Panel 0 / B44 176, 177, 178, 179 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 13

ETC 1 B 06.1J Panel 0 / B45 180, 181, 182, 183 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 14

ETC 1 B 06.1R Panel 0 / B46 184, 185, 186, 187 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 15

ETC 1 B 06.1Z Panel 0 / B47 188, 189, 190, 191 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 16

ETC 0 B 04.1A Panel 0 / B48 192, 193, 194, 195 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 01

ETC 0 B 04.1J Panel 0 / B49 196, 197, 198, 199 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 02

ETC 0 B 04.1R Panel 0 / B50 200, 201, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 03

ETC 0 B 04.1Z Panel 0 / B51 204, 205, 206, 207 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 04

ETC 1 B 07.1A Panel 0 / B52 208, 209, 120, 211 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 05

ETC 1 B 07.1J Panel 0 / B53 212, 213, 214, 215 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 06

ETC 1 B 07.1R Panel 0 / B54 216, 217, 218, 219 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 07

ETC 1 B 07.1Z Panel 0 / B55 220, 221, 222, 223 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 08

ETC 2 B 04.1A Panel 0 / B56 224, 225, 226, 227 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 09

ETC 2 B 04.1J Panel 0 / B57 228,229, 230, 231 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 10

ETC 2 B 04.1R Panel 0 / B58 232, 233, 234, 235 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 11

ETC 2 B 04.1Z Panel 0 / B59 236, 237, 238, 239 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 12

ETC 1 B 08.1A Panel 0 / B60 240, 241, 242, 243 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 13

ETC 1 B 08.1J Panel 0 / B61 244, 245, 246, 247 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 14

ETC 1 B 08.1R Panel 0 / B62 248, 249, 250, 251 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 15

ETC 1 B 08.1Z Panel 0 / B63 252, 253, 254, 255 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 16

ETC 0 B 05.1A Panel 4 / B00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 01

ETC car-tridge

From GT4C-A connector position

To panel / con-nector position

Front ports in CPETS-F panel through this cable

Front ports used for TR3 A-interface

Table 29 Balanced panels in the cabling cabinet - A-interface (Cont.)

Page 64: ET

64 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ebded

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)

ETC 0 B 05.1J Panel 4 / B01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 02

ETC 0 B 05.1R Panel 4 / B02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 03

ETC 0 B 05.1Z Panel 4 / B03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 04

ETC 2 B 05.1A Panel 4 / B04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 05

ETC 2 B 05.1J Panel 4 / B05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 06

ETC 2 B 05.1R Panel 4 / B06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 07

ETC 2 B 05.1Z Panel 4 / B07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 08

ETC 0 B 06.1A Panel 4 / B08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 09

ETC 0 B 06.1J Panel 4 / B09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 10

ETC 0 B 06.1R Panel 4 / B10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 11

ETC 0 B 06.1Z Panel 4 / B11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 12

ETC 2 B 06.1A Panel 4 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 13

ETC 2 B 06.1J Panel 4 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 14

ETC 2 B 06.1R Panel 4 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 15

ETC 2 B 06.1Z Panel 4 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 16

ETC 0 B 07.1A Panel 4 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 01

ETC 0 B 07.1J Panel 4 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 02

ETC 0 B 07.1R Panel 4 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 03

ETC 0 B 07.1Z Panel 4 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 04

ETC 2 B 07.1A Panel 4 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 05

ETC 2 B 07.1J Panel 4 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 06

ETC 2 B 07.1R Panel 4 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 07

ETC 2 B 07.1Z Panel 4 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 08

ETC 0 B 08.1A Panel 4 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 09

ETC 0 B 08.1J Panel 4 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 10

ETC 0 B 08.1R Panel 4 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 11

ETC 0 B 08.1Z Panel 4 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 12

ETC 2 B 08.1A Panel 4 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 13

ETC 2 B 08.1J Panel 4 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 14

ETC 2 B 08.1R Panel 4 / B30 120, 121, 122,123 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 15

ETC 2 B 08.1Z Panel 4 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 16

ETC car-tridge

From GT4C-A connector position

To panel / con-nector position

Front ports in CPETS-F panel through this cable

Front ports used for TR3 A-interface

Table 29 Balanced panels in the cabling cabinet - A-interface (Cont.)

Page 65: ET

DN70617303Issue 1-0

65

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1/T1 (PCM) balanced trunk cable panels (CPETS-Eand CPETS-F)

Id:0900d805804ebded

4.3.2 TCSM3i for combined BSC/TCSM installation optionThe cabling cabinet is not used with the TCSA cabinet in the TCSM3i for combined BSC/TCSM installation option. Instead, the optical cabling from the front connectors of the ETS2 plug-in units is routed out of the cabinet through the CPGO at the cabinet top.

From car-tridge

TR3 unit slot From ET16 slot and connector position

ET panel / front ports through this cable

TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 128, 129, 130, 131

TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 132, 133, 134, 135

TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 136, 137, 138, 139

TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 140, 141, 142, 143

TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 144, 145, 146, 147

TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 148, 149, 150, 151

TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 152, 153, 154, 155

TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 156, 157, 158, 159

TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 160, 161, 162, 163

TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 164, 165, 166, 167

TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 168, 169, 170, 171

TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 172, 173, 174, 175

TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 176, 177, 178, 179

TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 180, 181, 182, 183

TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 184, 185, 186, 187

TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 188, 189, 190, 191

TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 192, 193, 194, 195

TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 196, 197, 198, 199

TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 200, 201, 202, 203

TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 204, 205, 206, 207

TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 208, 209, 210, 211

TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 212, 213, 214, 215

TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 216, 217, 218, 219

TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 220, 221, 222, 223

Notes

*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C cartridge is used for transcoder connections of one BSC.

Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used for transcoder connections of two BSCs (one half of the TC2C cartridge for one BSC and the other half for the other BSC).

Table 30 Balanced panels in the cabling cabinet - Ater-interface

Page 66: ET

66 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

5 E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

5.1 Connector panels CPETC-E and CPETC-F with D37 con-nector packsThe small CPETC-E connector panel and the large CPETC-F connector panels are used for E1 (PCM) unbalanced trunk cables.

Cabling of the CPETC-E panels is described in the cabling lists delivered in the Site Doc-uments binder. The CPETC-E is installed at the BSCC cabinet top (one panel) or in the optional cabling cabinet (a total of four small panels, because there are three small panels in the cabinet and an additional small panel at the cabling cabinet top in first deliveries). The installation of the connector panel at the equipment cabinet top requires the use of Roof adapter (RACP) and the installation of the connector panel at the cabling cabinet top in first deliveries requires the use of Roof adapter 2 (RACP2).

For details of the panel, see figure Connector panel CPETC-E.

Figure 14 CPETC-E panel

Cabling of the CPETC-F panels is described in the cabling lists delivered in the Site Doc-uments binder. The CPETC-F is installed in the optional cabling cabinet (two panels). For more information on the panel, see the following figure.

00

02

04

06

08

10

01

03

05

07

09

11

DN05160363 CPETC-E

RxTx RxTx RxTx RxTx

00

78 56 34 12

01 02 03

Page 67: ET

DN70617303Issue 1-0

67

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

Figure 15 CPETC-F panel

5.2 Flexi BSCDepending on the maximum number ET interfaces, the Flexi BSC can be used either with or without an optional cabling cabinet.

CPETC-F

00 01 02 03 04 05 06 07

08 09 10 11 12 13 14 15

16 17 18 19 20 21 22 23

24 25 26 27 28 29 30 31

32 33 34 35 36 37 38 39

48 49 50 51 52 53 54 55

56 57 58 59 60 61 62 63

40 41 42 43 44 45 46 47

DN0626419

Page 68: ET

68 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

5.2.1 Optional cabling cabinet is not usedThe optional cabling cabinet is not needed, if the number ET interfaces needed does not exceed 48.

The unbalanced (asymmetrical) PCM trunk circuit interfaces are cabled by using coaxial cable connectors from the CPETC-E panels, and the recommended cable type for E1 coaxial trunk cable is CPRD. See the following table and figure.

Figure 16 CPRD cable assembly (panel end connector mounted)

The equipping order of the CPETC-E panel in first deliveries is presented in the following table.

Cable type: Filotex ET 267 380

Cable connector: D37 connector body, type FCI DC8W8PA00; or ITT Cannon DCM-8W8P-A197

Coaxial inserts: Rosenberger 55S101-302E2; IMS 307.23.2415.421

A1 A8

DN99257685

ETC car-tridge

From SGC1C-A connector position

To CPETC-E connector position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

ETC 0 B 19.1A B 00 00 (4*ET) ET368,ET369,ET370,ET371

ETC 0 B 19.1J B 01 01 (4*ET) ET372,ET373,ET374,ET375

ETC 0 B 19.1R B 02 02 (4*ET) ET376,ET377,ET378,ET379

ETC 0 B 19.1Z B 03 03 (4*ET) ET380,ET381,ET382,ET383

ETC 0 B 20.1A B 04 04 (4*ET) ET256,ET257,ET258,ET259

ETC 0 B 20.1J B 05 05 (4*ET) ET260,ET261,ET262,ET263

ETC 0 B 20.1R B 06 06 (4*ET) ET264,ET265,ET266,ET267

ETC 0 B 20.1Z B 07 07 (4*ET) ET268,ET269,ET270,ET271

Table 31 Unbalanced panel at the BSCC cabinet top in first deliveries

Page 69: ET

DN70617303Issue 1-0

69

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

The equipping order of the CPETC-E panel in upgrade deliveries is presented in the fol-lowing table.

5.2.2 Optional cabling cabinet is usedIf more than 48 ET interfaces are needed, the cabling cabinet must be used with the Flexi BSC.

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)The following table shows the connector panels in the cabling cabinet.

ETC 0 B 21.1A B 08 08 (4*ET) ET272,ET273,ET274,ET275

ETC 0 B 21.1J B 09 09 (4*ET) ET276,ET277,ET278,ET279

ETC 0 B 21.1R B 10 10 (4*ET) ET280,ET281,ET282,ET283

ETC 0 B 21.1Z B 11 11 (4*ET) ET284,ET285,ET286,ET287

ETC car-tridge

From SGC1C-A connector position

To CPETC-E connector position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

Table 31 Unbalanced panel at the BSCC cabinet top in first deliveries (Cont.)

ETC car-tridge

From GT6C-A connector position

To CPETC-E connec-tor position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

ETC 0 B 01.1A B 00 00 (4*ET) ET512,ET513,ET514,ET515

ETC 0 B 01.1J B 01 01 (4*ET) ET516,ET517,ET518,ET519

ETC 0 B 01.1R B 02 02 (4*ET) ET520,ET521,ET522,ET523

ETC 0 B 01.1Z B 03 03 (4*ET) ET524,ET525,ET526,ET527

ETC 0 B 02.1A B 04 04 (4*ET) ET528,ET529,ET530,ET531

ETC 0 B 02.1J B 05 05 (4*ET) ET532,ET533,ET534,ET535

ETC 0 B 02.1R B 06 06 (4*ET) ET536,ET537,ET538,ET539

ETC 0 B 02.1Z B 07 07 (4*ET) ET540,ET541,ET542,ET543

ETC 0 B 03.1A B 08 08 (4*ET) ET544,ET545,ET546,ET547

ETC 0 B 03.1J B 09 09 (4*ET) ET548,ET549,ET550,ET551

ETC 0 B 03.1R B 10 10 (4*ET) ET552,ET553,ET554,ET555

ETC 0 B 03.1Z B 11 11 (4*ET) ET556,ET557,ET558,ET559

Table 32 Unbalanced panel at the BSCC cabinet top in upgrade deliveries

Panel number Connector panel

T00 CPETC-E

Table 33 Unbalanced connector panels for the Flexi BSC

Page 70: ET

70 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

The unbalanced (asymmetrical) PCM trunk circuit interfaces are cabled by using coaxial cable connectors from the CPETC-E or CPETC-F panels. The recommended cable type for E1 coaxial trunk cables is CPRD. See the following table and figure.

Figure 17 CPRD cable assembly (panel end connector mounted)

Equipping orderThe equipping order in the cabling cabinet in first deliveries is presented in the following table.

0 CPETC-F

1 CPETC-E

2 CPETC-E

3 CPETC-E

4 CPETC-F

Cable type Filotex ET 267 380

Cable connector D37 connector body, type FCI DC8W8PA00; or ITT Cannon DCM-8W8P-A197

Coaxial inserts Rosenberger 55S101-302E2; IMS 307.23.2415.421

Table 34 Recommended cable type for E1 coaxial trunk cables (CPRD)

Panel number Connector panel

Table 33 Unbalanced connector panels for the Flexi BSC (Cont.)

A1 A8

DN99257685

Page 71: ET

DN70617303Issue 1-0

71

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Multicoaxial front ports in unbalanced panel through this cable

Corresponding external ET numbers

ETC 0 B 22.1A Panel 00 / B 00 00 (4*ET) ET256,ET257,ET258,ET259

ETC 0 B 22.1J Panel 00 / B 01 01 (4*ET) ET260,ET261,ET262,ET263

ETC 0 B 22.1R Panel 00 / B 02 02 (4*ET) ET264,ET265,ET266,ET267

ETC 0 B 22.1Z Panel 00 / B 03 03 (4*ET) ET268,ET269,ET270,ET271

ETC 0 B 23.1A Panel 00 / B 04 04 (4*ET) ET304,ET305,ET306,ET307

ETC 0 B 23.1J Panel 00 / B 05 05 (4*ET) ET308,ET309,ET310,ET311

ETC 0 B 23.1R Panel 00 / B 06 06 (4*ET) ET312,ET313,ET314,ET315

ETC 0 B 23.1Z Panel 00 / B 07 07 (4*ET) ET316,ET317,ET318,ET319

ETC 0 B 24.1A Panel 00 / B 08 08 (4*ET) ET320,ET321,ET322,ET323

ETC 0 B 24.1J Panel 00 / B 09 09 (4*ET) ET324,ET325,ET326,ET327

ETC 0 B 24.1R Panel 00 / B 10 10 (4*ET) ET328,ET329,ET330,ET331

ETC 0 B 24.1Z Panel 00 / B 11 11 (4*ET) ET332,ET333,ET334,ET335

ETC 0 B 25.1A Panel 00 / B 12 12 (4*ET) ET336,ET337,ET338,ET339

ETC 0 B 25.1J Panel 00 / B 13 13 (4*ET) ET340,ET341,ET342,ET343

ETC 0 B 25.1R Panel 00 / B 14 14 (4*ET) ET344,ET345,ET346,ET347

ETC 0 B 25.1Z Panel 00 / B 15 15 (4*ET) ET348,ET349,ET350,ET351

ETC 0 B 26.1A Panel 00 / B 16 16 (4*ET) ET352,ET353,ET354,ET355

ETC 0 B 26.1J Panel 00 / B 17 17 (4*ET) ET356,ET357,ET358,ET359

ETC 0 B 26.1R Panel 00 / B 18 18 (4*ET) ET360,ET361,ET362,ET363

ETC 0 B 26.1Z Panel 00 / B 19 19 (4*ET) ET364,ET365,ET366,ET367

ETC 1 B 28.1A Panel 00 / B 20 20 (4*ET) ET640,ET641,ET642,ET643

ETC 1 B 28.1J Panel 00 / B 21 21 (4*ET) ET644,ET645,ET646,ET647

ETC 1 B 28.1R Panel 00 / B 22 22 (4*ET) ET648,ET649,ET650,ET651

ETC 1 B 28.1Z Panel 00 / B 23 23 (4*ET) ET652,ET653,ET654,ET655

ETC 1 B 29.1A Panel 00 / B 24 24 (4*ET) ET624,ET625,ET626,ET627

ETC 1 B 29.1J Panel 00 / B 25 25 (4*ET) ET628,ET629,ET630,ET631

ETC 1 B 29.1R Panel 00 / B 26 26 (4*ET) ET632,ET633,ET634,ET635

ETC 1 B 29.1Z Panel 00 / B 27 27 (4*ET) ET636,ET637,ET638,ET639

ETC 1 B 30.1A Panel 00 / B 28 28 (4*ET) ET512,ET513,ET514,ET515

ETC 1 B 30.1J Panel 00 / B 29 29 (4*ET) ET516,ET517,ET518,ET519

ETC 1 B 30.1R Panel 00 / B 30 30 (4*ET) ET520,ET521,ET522,ET523

ETC 1 B 30.1Z Panel 00 / B 31 31 (4*ET) ET524,ET525,ET526,ET527

Table 35 Unbalanced panels in first deliveries

Page 72: ET

72 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

ETC 1 B 31.1A Panel 00 / B 32 32 (4*ET) ET528,ET529,ET530,ET531

ETC 1 B 31.1J Panel 00 / B 33 33 (4*ET) ET532,ET533,ET534,ET535

ETC 1 B 31.1R Panel 00 / B 34 34 (4*ET) ET536,ET537,ET538,ET539

ETC 1 B 31.1Z Panel 00 / B 35 35 (4*ET) ET540,ET541,ET542,ET543

ETC 1 B 32.1A Panel 00 / B 36 36 (4*ET) ET544,ET545,ET546,ET547

ETC 1 B 32.1J Panel 00 / B 37 37 (4*ET) ET548,ET549,ET550,ET551

ETC 1 B 32.1R Panel 00 / B 38 38 (4*ET) ET552,ET553,ET554,ET555

ETC 1 B 32.1Z Panel 00 / B 39 39 (4*ET) ET556,ET557,ET558,ET559

ETC 1 B 33.1A Panel 00 / B 40 40 (4*ET) ET560,ET561,ET562,ET563

ETC 1 B 33.1J Panel 00 / B 41 41 (4*ET) ET564,ET565,ET566,ET567

ETC 1 B 33.1R Panel 00 / B 42 42 (4*ET) ET568,ET569,ET570,ET571

ETC 1 B 33.1Z Panel 00 / B 43 43 (4*ET) ET572,ET573,ET574,ET575

ETC 1 B 34.1A Panel 00 / B 44 44 (4*ET) ET576,ET577,ET578,ET579

ETC 1 B 34.1J Panel 00 / B 45 45 (4*ET) ET580,ET581,ET582,ET583

ETC 1 B 34.1R Panel 00 / B 46 46 (4*ET) ET584,ET585,ET586,ET587

ETC 1 B 34.1Z Panel 00 / B 47 47 (4*ET) ET588,ET589,ET590,ET591

ETC 1 B 35.1A Panel 00 / B 48 48 (4*ET) ET592,ET593,ET594,ET595

ETC 1 B 35.1J Panel 00 / B 49 49 (4*ET) ET596,ET597,ET598,ET599

ETC 1 B 35.1R Panel 00 / B 50 50 (4*ET) ET600,ET601,ET602,ET603

ETC 1 B 35.1Z Panel 00 / B 51 51 (4*ET) ET604,ET605,ET606,ET607

ETC 1 B 36.1A Panel 00 / B 52 52 (4*ET) ET608,ET609,ET610,ET611

ETC 1 B 36.1J Panel 00 / B 53 53 (4*ET) ET612,ET613,ET614,ET615

ETC 1 B 36.1R Panel 00 / B 54 54 (4*ET) ET616,ET617,ET618,ET619

ETC 1 B 36.1Z Panel 00 / B 55 55 (4*ET) ET620,ET621,ET622,ET623

GTIC 0 B 10.1A Panel 00 / B 56 56 (4*ET) ET1392,ET1393,ET1394,ET1395

GTIC 0 B 10.1J Panel 00 / B 57 57 (4*ET) ET1396,ET1397,ET1398,ET1399

GTIC 0 B 10.1R Panel 00 / B 58 58 (4*ET) ET1400,ET1401,ET1402,ET1403

GTIC 0 B 10.1Z Panel 00 / B 59 59 (4*ET) ET1404,ET1405,ET1406,ET1407

GTIC 0 B 11.1A Panel 00 / B 60 60 (4*ET) ET1280,ET1281,ET1282,ET1283

GTIC 0 B 11.1J Panel 00 / B 61 61 (4*ET) ET1284,ET1285,ET1286,ET1287

GTIC 0 B 11.1R Panel 00 / B 62 62 (4*ET) ET1288,ET1289,ET1290,ET1291

GTIC 0 B 11.1Z Panel 00 / B 63 63 (4*ET) ET1292,ET1293,ET1294,ET1295

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Multicoaxial front ports in unbalanced panel through this cable

Corresponding external ET numbers

Table 35 Unbalanced panels in first deliveries (Cont.)

Page 73: ET

DN70617303Issue 1-0

73

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

GTIC 1 B 10.1A Panel 01 / B 00 00 (4*ET) ET1920,ET1921,ET1922,ET1923

GTIC 1 B 10.1J Panel 01 / B 01 01 (4*ET) ET1924,ET1925,ET1926,ET1927

GTIC 1 B 10.1R Panel 01 / B 02 02 (4*ET) ET1928,ET1929,ET1930,ET1931

GTIC 1 B 10.1Z Panel 01 / B 03 03 (4*ET) ET1932,ET1933,ET1934,ET1935

GTIC 1 B 11.1A Panel 01 / B 04 04 (4*ET) ET1936,ET1937,ET1938,ET1939

GTIC 1 B 11.1J Panel 01 / B 05 05 (4*ET) ET1940,ET1941,ET1942,ET1943

GTIC 1 B 11.1R Panel 01 / B 06 06 (4*ET) ET1944,ET1945,ET1946,ET1947

GTIC 1 B 11.1Z Panel 01 / B 07 07 (4*ET) ET1948,ET1949,ET1950,ET1951

GTIC 1 B 12.1A Panel 01 / B 08 08 (4*ET) ET1952,ET1953,ET1954,ET1955

GTIC 1 B 12.1J Panel 01 / B 09 09 (4*ET) ET1956,ET1957,ET1958,ET1959

GTIC 1 B 12.1R Panel 01 / B 10 10 (4*ET) ET1960,ET1961,ET1962,ET1963

GTIC 1 B 12.1Z Panel 01 / B 11 11 (4*ET) ET1964,ET1965,ET1966,ET1967

GTIC 1 B 13.1A Panel 02 / B 00 00 (4*ET) ET1968,ET1969,ET1970,ET1971

GTIC 1 B 13.1J Panel 02 / B 01 01 (4*ET) ET1972,ET1973,ET1974,ET1975

GTIC 1 B 13.1R Panel 02 / B 02 02 (4*ET) ET1976,ET1977,ET1978,ET1979

GTIC 1 B 13.1Z Panel 02 / B 03 03 (4*ET) ET1980,ET1981,ET1982,ET1983

GTIC 1 B 14.1A Panel 02 / B 04 04 (4*ET) ET1984,ET1985,ET1986,ET1987

GTIC 1 B 14.1J Panel 02 / B 05 05 (4*ET) ET1988,ET1989,ET1990,ET1991

GTIC 1 B 14.1R Panel 02 / B 06 06 (4*ET) ET1992,ET1993,ET1994,ET1995

GTIC 1 B 14.1Z Panel 02 / B 07 07 (4*ET) ET1996,ET1997,ET1998,ET1999

GTIC 1 B 15.1A Panel 02 / B 08 08 (4*ET) ET2000,ET2001,ET2002,ET2003

GTIC 1 B 15.1J Panel 02 / B 09 09 (4*ET) ET2004,ET2005,ET2006,ET2007

GTIC 1 B 15.1R Panel 02 / B 10 10 (4*ET) ET2008,ET2009,ET2010,ET2011

GTIC 1 B 15.1Z Panel 02 / B 11 11 (4*ET) ET2012,ET2013,ET2014,ET2015

GTIC 1 B 16.1A Panel 03 / B 00 00 (4*ET) ET2016,ET2017,ET2018,ET2019

GTIC 1 B 16.1J Panel 03 / B 01 01 (4*ET) ET2020,ET2021,ET2022,ET2023

GTIC 1 B 16.1R Panel 03 / B 02 02 (4*ET) ET2024,ET2025,ET2026,ET2027

GTIC 1 B 16.1Z Panel 03 / B 03 03 (4*ET) ET2028,ET2029,ET2030,ET2031

GTIC 1 B 17.1A Panel 03 / B 04 04 (4*ET) ET2032,ET2033,ET2034,ET2035

GTIC 1 B 17.1J Panel 03 / B 05 05 (4*ET) ET2036,ET2037,ET2038,ET2039

GTIC 1 B 17.1R Panel 03 / B 06 06 (4*ET) ET2040,ET2041,ET2042,ET2043

GTIC 1 B 17.1Z Panel 03 / B 07 07 (4*ET) ET2044,ET2045,ET2046,ET2047

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Multicoaxial front ports in unbalanced panel through this cable

Corresponding external ET numbers

Table 35 Unbalanced panels in first deliveries (Cont.)

Page 74: ET

74 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

ETC 2 B 19.1A Panel 03 / B 08 08 (4*ET) ET1136,ET1137,ET1138,ET1139

ETC 2 B 19.1J Panel 03 / B 09 09 (4*ET) ET1140,ET1141,ET1142,ET1143

ETC 2 B 19.1R Panel 03 / B 10 10 (4*ET) ET1140,ET1141,ET1142,ET1143

ETC 2 B 19.1Z Panel 03 / B 11 11 (4*ET) ET1140,ET1141,ET1142,ET1143

ETC 2 B 20.1A Panel 04 / B 00 00 (4*ET) ET1024,ET1025,ET1026,ET1027

ETC 2 B 20.1J Panel 04 / B 01 01 (4*ET) ET1028,ET1029,ET1030,ET1031

ETC 2 B 20.1R Panel 04 / B 02 02 (4*ET) ET1032,ET1033,ET1034,ET1035

ETC 2 B 20.1Z Panel 04 / B 03 03 (4*ET) ET1036,ET1037,ET1038,ET1039

ETC 2 B 21.1A Panel 04 / B 04 04 (4*ET) ET1040,ET1041,ET1042,ET1043

ETC 2 B 21.1J Panel 04 / B 05 05 (4*ET) ET1044,ET1045,ET1046,ET1047

ETC 2 B 21.1R Panel 04 / B 06 06 (4*ET) ET1048,ET1049,ET1050,ET1051

ETC 2 B 21.1Z Panel 04 / B 07 07 (4*ET) ET1052,ET1053,ET1054,ET1055

ETC 2 B 22.1A Panel 04 / B 08 08 (4*ET) ET1056,ET1057,ET1058,ET1059

ETC 2 B 22.1J Panel 04 / B 09 09 (4*ET) ET1060,ET1061,ET1062,ET1063

ETC 2 B 22.1R Panel 04 / B 10 10 (4*ET) ET1064,ET1065,ET1066,ET1067

ETC 2 B 22.1Z Panel 04 / B 11 11 (4*ET) ET1068,ET1069,ET1070,ET1071

ETC 2 B 23.1A Panel 04 / B 12 12 (4*ET) ET1072,ET1073,ET1074,ET1075

ETC 2 B 23.1J Panel 04 / B 13 13 (4*ET) ET1076,ET1077,ET1078,ET1079

ETC 2 B 23.1R Panel 04 / B 14 14 (4*ET) ET1080,ET1081,ET1082,ET1083

ETC 2 B 23.1Z Panel 04 / B 15 15 (4*ET) ET1084,ET1085,ET1086,ET1087

ETC 2 B 24.1A Panel 04 / B 16 16 (4*ET) ET1088,ET1089,ET1090,ET1091

ETC 2 B 24.1J Panel 04 / B 17 17 (4*ET) ET1092,ET1093,ET1094,ET1095

ETC 2 B 24.1R Panel 04 / B 18 18 (4*ET) ET1096,ET1097,ET1098,ET1099

ETC 2 B 24.1Z Panel 04 / B 19 19 (4*ET) ET1100,ET1101,ET1102,ET1103

ETC 2 B 25.1A Panel 04 / B 20 20 (4*ET) ET1104,ET1105,ET1106,ET1107

ETC 2 B 25.1J Panel 04 / B 21 21 (4*ET) ET1108,ET1109,ET1110,ET1111

ETC 2 B 25.1R Panel 04 / B 22 22 (4*ET) ET1112,ET1113,ET1114,ET1115

ETC 2 B 25.1Z Panel 04 / B 23 23 (4*ET) ET1116,ET1117,ET1118,ET1119

ETC 2 B 26.1A Panel 04 / B 24 24 (4*ET) ET1120,ET1121,ET1122,ET1123

ETC 2 B 26.1J Panel 04 / B 25 25 (4*ET) ET1124,ET1125,ET1126,ET1127

ETC 2 B 26.1R Panel 04 / B 26 26 (4*ET) ET1128,ET1129,ET1130,ET1131

ETC 2 B 26.1Z Panel 04 / B 27 27 (4*ET) ET1132,ET1133,ET1134,ET1135

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Multicoaxial front ports in unbalanced panel through this cable

Corresponding external ET numbers

Table 35 Unbalanced panels in first deliveries (Cont.)

Page 75: ET

DN70617303Issue 1-0

75

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

ETC 3 B 28.1A Panel 04 / B 28 28 (4*ET) ET896,ET897,ET898,ET899

ETC 3 B 28.1J Panel 04 / B 29 29 (4*ET) ET900,ET901,ET902,ET903

ETC 3 B 28.1R Panel 04 / B 30 30 (4*ET) ET904,ET905,ET906,ET907

ETC 3 B 28.1Z Panel 04 / B 31 31 (4*ET) ET908,ET909,ET910,ET911

ETC 3 B 29.1A Panel 04 / B 32 32 (4*ET) ET880,ET881,ET882,ET883

ETC 3 B 29.1J Panel 04 / B 33 33 (4*ET) ET884,ET885,ET886,ET887

ETC 3 B 29.1R Panel 04 / B 34 34 (4*ET) ET888,ET889,ET890,ET891

ETC 3 B 29.1Z Panel 04 / B 35 35 (4*ET) ET892,ET893,ET894,ET895

ETC 3 B 30.1A Panel 04 / B 36 36 (4*ET) ET768,ET769,ET770,ET771

ETC 3 B 30.1J Panel 04 / B 37 37 (4*ET) ET772,ET773,ET774,ET775

ETC 3 B 30.1R Panel 04 / B 38 38 (4*ET) ET776,ET777,ET778,ET779

ETC 3 B 30.1Z Panel 04 / B 39 39 (4*ET) ET780,ET781,ET782,ET783

ETC 3 B 31.1A Panel 04 / B 40 40 (4*ET) ET784,ET785,ET786,ET787

ETC 3 B 31.1J Panel 04 / B 41 41 (4*ET) ET788,ET789,ET790,ET791

ETC 3 B 31.1R Panel 04 / B 42 42 (4*ET) ET792,ET793,ET794,ET795

ETC 3 B 31.1Z Panel 04 / B 43 43 (4*ET) ET796,ET797,ET798,ET799

ETC 3 B 32.1A Panel 04 / B 44 44 (4*ET) ET800,ET801,ET802,ET803

ETC 3 B 32.1J Panel 04 / B 45 45 (4*ET) ET804,ET805,ET806,ET807

ETC 3 B 32.1R Panel 04 / B 46 46 (4*ET) ET808,ET809,ET810,ET811

ETC 3 B 32.1Z Panel 04 / B 47 47 (4*ET) ET812,ET813,ET814,ET815

ETC 3 B 33.1A Panel 04 / B 48 48 (4*ET) ET816,ET817,ET818,ET819

ETC 3 B 33.1J Panel 04 / B 49 49 (4*ET) ET820,ET821,ET822,ET823

ETC 3 B 33.1R Panel 04 / B 50 50 (4*ET) ET824,ET825,ET826,ET827

ETC 3 B 33.1Z Panel 04 / B 51 51 (4*ET) ET828,ET829,ET830,ET831

ETC 3 B 34.1A Panel 04 / B 52 52 (4*ET) ET832,ET833,ET834,ET835

ETC 3 B 34.1J Panel 04 / B 53 53 (4*ET) ET836,ET837,ET838,ET839

ETC 3 B 34.1R Panel 04 / B 54 54 (4*ET) ET840,ET841,ET842,ET843

ETC 3 B 34.1Z Panel 04 / B 55 55 (4*ET) ET844,ET845,ET846,ET847

ETC 3 B 35.1A Panel 04 / B 56 56 (4*ET) ET848,ET849,ET850,ET851

ETC 3 B 35.1J Panel 04 / B 57 57 (4*ET) ET852,ET853,ET854,ET855

ETC 3 B 35.1R Panel 04 / B 58 58 (4*ET) ET856,ET857,ET858,ET859

ETC 3 B 35.1Z Panel 04 / B 59 59 (4*ET) ET860,ET861,ET862,ET863

ETC 3 B 36.1A Panel 04 / B 60 60 (4*ET) ET864,ET865,ET866,ET867

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Multicoaxial front ports in unbalanced panel through this cable

Corresponding external ET numbers

Table 35 Unbalanced panels in first deliveries (Cont.)

Page 76: ET

76 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

The equipping order in the cabling cabinet in upgrade deliveries is presented in the fol-lowing table.

ETC 3 B 36.1J Panel 04 / B 61 61 (4*ET) ET868,ET869,ET870,ET871

ETC 3 B 36.1R Panel 04 / B 62 62 (4*ET) ET872,ET873,ET874,ET875

ETC 3 B 36.1Z Panel 04 / B 63 63 (4*ET) ET876,ET877,ET878,ET879

GTIC 0 B 12.1A Panel T00 / B 00 00 (4*ET) ET1296,ET1297,ET1298,ET1299

GTIC 0 B 12.1J Panel T00 / B 01 01 (4*ET) ET1300,ET1301,ET1302,ET1303

GTIC 0 B 12.1R Panel T00 / B 02 02 (4*ET) ET1304,ET1305,ET1306,ET1307

GTIC 0 B 12.1Z Panel T00 / B 03 03 (4*ET) ET1308,ET1309,ET1310,ET1311

GTIC 0 B 13.1A Panel T00 / B 04 04 (4*ET) ET1312,ET1313,ET1314,ET1315

GTIC 0 B 13.1J Panel T00 / B 05 05 (4*ET) ET1316,ET1317,ET1318,ET1319

GTIC 0 B 13.1R Panel T00 / B 06 06 (4*ET) ET1320,ET1321,ET1322,ET1323

GTIC 0 B 13.1Z Panel T00 / B 07 07 (4*ET) ET1324,ET1325,ET1326,ET1327

GTIC 0 B 14.1A Panel T00 / B 08 08 (4*ET) ET1328,ET1329,ET1330,ET1331

GTIC 0 B 14.1J Panel T00 / B 09 09 (4*ET) ET1332,ET1333,ET1334,ET1335

GTIC 0 B 14.1R Panel T00 / B 10 10 (4*ET) ET1336,ET1337,ET1338,ET1339

GTIC 0 B 14.1Z Panel T00 / B 11 11 (4*ET) ET1340,ET1341,ET1342,ET1343

ETC/GTIC index

From SGC1C-A connector position

To panel / connector position

Multicoaxial front ports in unbalanced panel through this cable

Corresponding external ET numbers

Table 35 Unbalanced panels in first deliveries (Cont.)

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

ETC 0 B 04.1A Panel 04 / B 56 56 (4*ET) ET560,ET561,ET562,ET563

ETC 0 B 04.1J Panel 04 / B 57 57 (4*ET) ET564,ET565,ET566,ET567

ETC 0 B 04.1R Panel 04 / B 58 58 (4*ET) ET568,ET569,ET570,ET571

ETC 0 B 04.1Z Panel 04 / B 59 59 (4*ET) ET572,ET573,ET574,ET575

ETC 1 B 01.1A Panel 04 / B 60 60 (4*ET) ET576,ET577,ET578,ET579

ETC 1 B 01.1J Panel 04 / B 61 61 (4*ET) ET580,ET581,ET582,ET583

ETC 1 B 01.1R Panel 04 / B 62 62 (4*ET) ET584,ET585,ET586,ET587

ETC 1 B 01.1Z Panel 04 / B 63 63 (4*ET) ET588,ET589,ET590,ET591

ETC 1 B 02.1A Panel 04 / B 48 48 (4*ET) ET592,ET593,ET594,ET595

ETC 1 B 02.1J Panel 04 / B 49 49 (4*ET) ET596,ET597,ET598,ET599

Table 36 Unbalanced panels in upgrade deliveries

Page 77: ET

DN70617303Issue 1-0

77

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

ETC 1 B 02.1R Panel 04 / B 50 50 (4*ET) ET600,ET601,ET602,ET603

ETC 1 B 02.1Z Panel 04 / B 51 51 (4*ET) ET604,ET605,ET606,ET607

ETC 1 B 03.1A Panel 04 / B 52 52 (4*ET) ET608,ET609,ET610,ET611

ETC 1 B 03.1J Panel 04 / B 53 53 (4*ET) ET612,ET613,ET614,ET615

ETC 1 B 03.1R Panel 04 / B 54 54 (4*ET) ET616,ET617,ET618,ET619

ETC 1 B 03.1Z Panel 04 / B 55 55 (4*ET) ET620,ET621,ET622,ET623

ETC 1 B 04.1A Panel 04 / B 40 40 (4*ET) ET624,ET625,ET626,ET627

ETC 1 B 04.1J Panel 04 / B 41 41 (4*ET) ET628,ET629,ET630,ET631

ETC 1 B 04.1R Panel 04 / B 42 42 (4*ET) ET632,ET633,ET634,ET635

ETC 1 B 04.1Z Panel 04 / B 43 43 (4*ET) ET636,ET637,ET638,ET639

GTIC 0 / ETC 5

B 01.1A (GTIC 0) / B03.1A (ETC 5) Panel 04 / B 44 44 (4*ET) ET904,ET905,ET906,ET907

GTIC 0 / ETC 5

B 01.1J (GTIC 0) / B03.1J (ETC 5) Panel 04 / B 45 45 (4*ET) ET908,ET909,ET910,ET911

GTIC 0 / ETC 5

B 01.1R (GTIC 0) / B03.1R (ETC 5) Panel 04 / B 46 46 (4*ET) ET912,ET913,ET914,ET915

GTIC 0 / ETC 5

B 01.1Z (GTIC 0) / B03.1Z (ETC 5) Panel 04 / B 47 47 (4*ET) ET916,ET917,ET918,ET919

GTIC 0 / ETC 5

B 02.1A (GTIC 0) / B04.1A (ETC 5) Panel 04 / B 32 32 (4*ET) ET920,ET921,ET922,ET923

GTIC 0 / ETC 5

B 02.1J (GTIC 0) / B04.1J (ETC 5) Panel 04 / B 33 33 (4*ET) ET924,ET925,ET926,ET927

GTIC 0 / ETC 5

B 02.1R (GTIC 0) / B04.1R (ETC 5) Panel 04 / B 34 34 (4*ET) ET928,ET929,ET930,ET931

GTIC 0 / ETC 5

B 02.1Z (GTIC 0) / B04.1Z (ETC 5) Panel 04 / B 35 35 (4*ET) ET932,ET933,ET934,ET935

GTIC 0 / ETC 5

B 03.1A (GTIC 0) / B05.1A (ETC 5) Panel 04 / B 36 36 (4*ET) ET936,ET937,ET938,ET939

GTIC 0 / ETC 5

B 03.1J (GTIC 0) / B05.1J (ETC 5) Panel 04 / B 37 37 (4*ET) ET940,ET941,ET942,ET943

GTIC 0 / ETC 5

B 03.1R (GTIC 0) / B05.1R (ETC 5) Panel 04 / B 38 38 (4*ET) ET944,ET945,ET946,ET947

GTIC 0 / ETC 5

B 03.1Z (GTIC 0) / B05.1Z (ETC 5) Panel 04 / B 39 39 (4*ET) ET948,ET949,ET950,ET951

GTIC 0 / ETC 5

B 04.1A (GTIC 0) / B06.1A (ETC 5) Panel 04 / B 24 24 (4*ET) ET816,ET817,ET818,ET819

GTIC 0 / ETC 5

B 04.1J (GTIC 0) / B06.1J (ETC 5) Panel 04 / B 25 25 (4*ET) ET820,ET821,ET822,ET823

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

Page 78: ET

78 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

GTIC 0 / ETC 5

B 04.1R (GTIC 0) / B06.1R (ETC 5) Panel 04 / B 26 26 (4*ET) ET824,ET825,ET826,ET827

GTIC 0 / ETC 5

B 04.1Z (GTIC 0) / B06.1Z (ETC 5) Panel 04 / B 27 27 (4*ET) ETET828,ET829,ET830,ET831

GTIC 0 / ETC 5

B 05.1A (GTIC 0) / B07.1A (ETC 5) Panel 04 / B 28 28 (4*ET)

ET1072,ET1073,ET1074,ET1075

GTIC 0 / ETC 5

B 05.1J (GTIC 0) / B07.1J (ETC 5) Panel 04 / B 29 29 (4*ET)

ET1076,ET1077,ET1078,ET1079

GTIC 0 / ETC 5

B 05.1R (GTIC 0) / B07.1R (ETC 5) Panel 04 / B 30 30 (4*ET)

ET1080,ET1081,ET1082,ET1083

GTIC 0 / ETC 5

B 05.1Z (GTIC 0) / B07.1Z (ETC 5) Panel 04 / B 31 31 (4*ET)

ET1084,ET1085,ET1086,ET1087

GTIC 0 / ETC 5

B 06.1A (GTIC 0) / B08.1A (ETC 5) Panel 04 / B 16 16 (4*ET)

ET1328,ET1329,ET1330,ET1331

GTIC 0 / ETC 5

B 06.1J (GTIC 0) / B08.1J (ETC 5) Panel 04 / B 17 17 (4*ET)

ET1332,ET1333,ET1334,ET1335

GTIC 0 / ETC 5

B 06.1R (GTIC 0) / B08.1R (ETC 5) Panel 04 / B 18 18 (4*ET)

ET1336,ET1337,ET1338,ET1339

GTIC 0 / ETC 5

B 06.1Z (GTIC 0) / B08.1Z (ETC 5) Panel 04 / B 19 19 (4*ET)

ET1340,ET1341,ET1342,ET1343

GTIC 0 B 07.1A Panel 04 / B 20 20 (4*ET)ET1792,ET1793,ET1794,ET1795

GTIC 0 B 07.1J Panel 04 / B 21 21 (4*ET)ET1796,ET1797,ET1798,ET1799

GTIC 0 B 07.1R Panel 04 / B 22 22 (4*ET)ET1800,ET1801,ET1802,ET1803

GTIC 0 B 07.1Z Panel 04 / B 23 23 (4*ET)ET1804,ET1805,ET1806,ET1807

GTIC 0 B 08.1A Panel 04 / B 08 08 (4*ET)ET1808,ET1809,ET1810,ET1811

GTIC 0 B 08.1J Panel 04 / B 09 09 (4*ET)ET1812,ET1813,ET1814,ET1815

GTIC 0 B 08.1R Panel 04 / B 10 10 (4*ET)ET1816,ET1817,ET1818,ET1819

GTIC 0 B 08.1Z Panel 04 / B 11 11 (4*ET)ET1820,ET1821,ET1822,ET1823

GTIC 1 B 01.1A Panel 04 / B 12 12 (4*ET)ET1408,ET1409,ET1410,ET1411

GTIC 1 B 01.1J Panel 04 / B 13 13 (4*ET)ET1412,ET1413,ET1414,ET1415

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

Page 79: ET

DN70617303Issue 1-0

79

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

GTIC 1 B 01.1R Panel 04 / B 14 14 (4*ET)ET1416,ET1417,ET1418,ET1419

GTIC 1 B 01.1Z Panel 04 / B 15 15 (4*ET)ET1420,ET1421,ET1422,ET1423

GTIC 1 B 02.1A Panel 04 / B 00 00 (4*ET)ET1424,ET1425,ET1426,ET1427

GTIC 1 B 02.1J Panel 04 / B 01 01 (4*ET)ET1428,ET1429,ET1430,ET1431

GTIC 1 B 02.1R Panel 04 / B 02 02 (4*ET)ET1432,ET1433,ET1434,ET1435

GTIC 1 B 02.1Z Panel 04 / B 03 03 (4*ET)ET1436,ET1437,ET1438,ET1439

GTIC 1 B 03.1A Panel 04 / B 04 04 (4*ET)ET1440,ET1441,ET1442,ET1443

GTIC 1 B 03.1J Panel 04 / B 05 05 (4*ET)ET1444,ET1445,ET1446,ET1447

GTIC 1 B 03.1R Panel 04 / B 06 06 (4*ET)ET1448,ET1449,ET1450,ET1451

GTIC 1 B 03.1Z Panel 04 / B 07 07 (4*ET)ET1452,ET1453,ET1454,ET1455

GTIC 1 B 04.1A Panel 03 / B 10 10 (4*ET)ET1456,ET1457,ET1458,ET1459

GTIC 1 B 04.1J Panel 03 / B 11 11 (4*ET)ET1460,ET1461,ET1462,ET1463

GTIC 1 B 04.1R Panel 03 / B 08 08 (4*ET)ET1464,ET1465,ET1466,ET1467

GTIC 1 B 04.1Z Panel 03 / B 09 09 (4*ET)ET1468,ET1469,ET1470,ET1471

GTIC 1 B 05.1A Panel 03 / B 06 06 (4*ET)ET1472,ET1473,ET1474,ET1475

GTIC 1 B 05.1J Panel 03 / B 07 07 (4*ET)ET1476,ET1477,ET1478,ET1479

GTIC 1 B 05.1R Panel 03 / B 04 04 (4*ET)ET1480,ET1481,ET1482,ET1483

GTIC 1 B 05.1Z Panel 03 / B 05 05 (4*ET)ET1484,ET1485,ET1486,ET1487

GTIC 1 B 06.1A Panel 03 / B 02 02 (4*ET)ET1488,ET1489,ET1490,ET1491

GTIC 1 B 06.1J Panel 03 / B 03 03 (4*ET)ET1492,ET1493,ET1494,ET1495

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

Page 80: ET

80 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

GTIC 1 B 06.1R Panel 03 / B 00 00 (4*ET)ET1496,ET1497,ET1498,ET1499

GTIC 1 B 06.1Z Panel 03 / B 01 01 (4*ET)ET1500,ET1501,ET1502,ET1503

GTIC 1 B 07.1A Panel 02 / B 10 10 (4*ET)ET1504,ET1505,ET1506,ET1507

GTIC 1 B 07.1J Panel 02 / B 11 11 (4*ET)ET1508,ET1509,ET1510,ET1511

GTIC 1 B 07.1R Panel 02 / B 08 08 (4*ET)ET1512,ET1513,ET1514,ET1515

GTIC 1 B 07.1Z Panel 02 / B 09 09 (4*ET)ET1516,ET1517,ET1518,ET1519

GTIC 1 B 08.1A Panel 02 / B 06 06 (4*ET)ET1520,ET1521,ET1522,ET1523

GTIC 1 B 08.1J Panel 02 / B 07 07 (4*ET)ET1524,ET1525,ET1526,ET1527

GTIC 1 B 08.1R Panel 02 / B 04 04 (4*ET)ET1528,ET1529,ET1530,ET1531

GTIC 1 B 08.1Z Panel 02 / B 05 05 (4*ET)ET1532,ET1533,ET1534,ET1535

ETC 2 B 01.1A Panel 02 / B 02 02 (4*ET)ET1344,ET1345,ET1346,ET1347

ETC 2 B 01.1J Panel 02 / B 03 03 (4*ET)ET1348,ET1349,ET1350,ET1351

ETC 2 B 01.1R Panel 02 / B 00 00 (4*ET)ET1352,ET1353,ET1354,ET1355

ETC 2 B 01.1Z Panel 02 / B 01 01 (4*ET)ET1356,ET1357,ET1358,ET1359

ETC 2 B 02.1A Panel 01 / B 10 10 (4*ET)ET1360,ET1361,ET1362,ET1363

ETC 2 B 02.1J Panel 01 / B 11 11 (4*ET)ET1364,ET1365,ET1366,ET1367

ETC 2 B 02.1R Panel 01 / B 08 08 (4*ET)ET1368,ET1369,ET1370,ET1371

ETC 2 B 02.1Z Panel 01 / B 09 09 (4*ET)ET1372,ET1373,ET1374,ET1375

ETC 2 B 03.1A Panel 01 / B 06 06 (4*ET)ET1376,ET1377,ET1378,ET1379

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

Page 81: ET

DN70617303Issue 1-0

81

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

ETC 2 B 03.1J Panel 01 / B 07 07 (4*ET)ET1380,ET1381,ET1382,ET1383

ETC 2 B 03.1R Panel 01 / B 04 04 (4*ET)ET1384,ET1385,ET1386,ET1387

ETC 2 B 03.1Z Panel 01 / B 05 05 (4*ET)ET1388,ET1389,ET1390,ET1391

ETC 2 B 04.1A Panel 01 / B 02 02 (4*ET)ET1392,ET1393,ET1394,ET1395

ETC 2 B 04.1J Panel 01 / B 03 03 (4*ET)ET1396,ET1397,ET1398,ET1399

ETC 2 B 04.1R Panel 01 / B 00 00 (4*ET)ET1400,ET1401,ET1402,ET1403

ETC 2 B 04.1Z Panel 01 / B 01 01 (4*ET)ET1404,ET1405,ET1406,ET1407

ETC 2 B 05.1A Panel 00 / B 56 56 (4*ET)ET1600,ET1601,ET1602,ET1603

ETC 2 B 05.1J Panel 00 / B 57 57 (4*ET)ET1604,ET1605,ET1606,ET1607

ETC 2 B 05.1R Panel 00 / B 58 58 (4*ET)ET1608,ET1609,ET1610,ET1611

ETC 2 B 05.1Z Panel 00 / B 59 59 (4*ET)ET1612,ET1613,ET1614,ET1615

ETC 2 B 06.1A Panel 00 / B 60 60 (4*ET)ET1616,ET1617,ET1618,ET1619

ETC 2 B 06.1J Panel 00 / B 61 61 (4*ET)ET1620,ET1621,ET1622,ET1623

ETC 2 B 06.1R Panel 00 / B 62 62 (4*ET)ET1624,ET1625,ET1626,ET1627

ETC 2 B 06.1Z Panel 00 / B 63 63 (4*ET)ET1628,ET1629,ET1630,ET1631

ETC 2 B 07.1A Panel 00 / B 48 48 (4*ET)ET1632,ET1633,ET1634,ET1635

ETC 2 B 07.1J Panel 00 / B 49 49 (4*ET)ET1636,ET1637,ET1638,ET1639

ETC 2 B 07.1R Panel 00 / B 50 50 (4*ET)ET1640,ET1641,ET1642,ET1643

ETC 2 B 07.1Z Panel 00 / B 51 51 (4*ET)ET1644,ET1645,ET1646,ET1647

ETC 2 B 08.1A Panel 00 / B 52 52 (4*ET)ET1648,ET1649,ET1650,ET1651

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

Page 82: ET

82 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

ETC 2 B 08.1J Panel 00 / B 53 53 (4*ET)ET1652,ET1653,ET1654,ET1655

ETC 2 B 08.1R Panel 00 / B 54 54 (4*ET)ET1656,ET1657,ET1658,ET1659

ETC 2 B 08.1Z Panel 00 / B 55 55 (4*ET)ET1660,ET1661,ET1662,ET1663

ETC 3 B 01.1A Panel 00 / B 40 40 (4*ET)ET1664,ET1665,ET1666,ET1667

ETC 3 B 01.1J Panel 00 / B 41 41 (4*ET)ET1668,ET1669,ET1670,ET1671

ETC 3 B 01.1R Panel 00 / B 42 42 (4*ET)ET1672,ET1673,ET1674,ET1675

ETC 3 B 01.1Z Panel 00 / B 43 43 (4*ET)ET1676,ET1677,ET1678,ET1679

ETC 3 B 02.1A Panel 00 / B 44 44 (4*ET)ET1680,ET1681,ET1682,ET1683

ETC 3 B 02.1J Panel 00 / B 45 45 (4*ET)ET1684,ET1685,ET1686,ET1687

ETC 3 B 02.1R Panel 00 / B 46 46 (4*ET)ET1688,ET1689,ET1690,ET1691

ETC 3 B 02.1Z Panel 00 / B 47 47 (4*ET)ET1692,ET1693,ET1694,ET1695

ETC 3 B 03.1A Panel 00 / B 32 32 (4*ET)ET1696,ET1697,ET1698,ET1699

ETC 3 B 03.1J Panel 00 / B 33 33 (4*ET)ET1700,ET1701,ET1702,ET1703

ETC 3 B 03.1R Panel 00 / B 34 34 (4*ET)ET1704,ET1705,ET1706,ET1707

ETC 3 B 03.1Z Panel 00 / B 35 35 (4*ET)ET1708,ET1709,ET1710,ET1711

ETC 3 B 04.1A Panel 00 / B 36 36 (4*ET)ET1712,ET1713,ET1714,ET1715

ETC 3 B 04.1J Panel 00 / B 37 37 (4*ET)ET1716,ET1717,ET1718,ET1719

ETC 3 B 04.1R Panel 00 / B 38 38 (4*ET)ET1720,ET1721,ET1722,ET1723

ETC 3 B 04.1Z Panel 00 / B 39 39 (4*ET)ET1724,ET1725,ET1726,ET1727

ETC 3 B 05.1A Panel 00 / B 24 24 (4*ET)ET1728,ET1729,ET1730,ET1731

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

Page 83: ET

DN70617303Issue 1-0

83

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

ETC 3 B 05.1J Panel 00 / B 25 25 (4*ET)ET1732,ET1733,ET1734,ET1735

ETC 3 B 05.1R Panel 00 / B 26 26 (4*ET)ET1736,ET1737,ET1738,ET1739

ETC 3 B 05.1Z Panel 00 / B 27 27 (4*ET)ET1740,ET1741,ET1742,ET1743

ETC 3 B 06.1A Panel 00 / B 28 28 (4*ET)ET1744,ET1745,ET1746,ET1747

ETC 3 B 06.1J Panel 00 / B 29 29 (4*ET)ET1748,ET1749,ET1750,ET1751

ETC 3 B 06.1R Panel 00 / B 30 30 (4*ET)ET1752,ET1753,ET1754,ET1755

ETC 3 B 06.1Z Panel 00 / B 31 31 (4*ET)ET1756,ET1757,ET1758,ET1759

ETC 3 B 07.1A Panel 00 / B 16 16 (4*ET)ET1760,ET1761,ET1762,ET1763

ETC 3 B 07.1J Panel 00 / B 17 17 (4*ET)ET1764,ET1765,ET1766,ET1767

ETC 3 B 07.1R Panel 00 / B 18 18 (4*ET)ET1768,ET1769,ET1770,ET1771

ETC 3 B 07.1Z Panel 00 / B 19 19 (4*ET)ET1772,ET1773,ET1774,ET1775

ETC 3 B 08.1A Panel 00 / B 20 20 (4*ET)ET1776,ET1777,ET1778,ET1779

ETC 3 B 08.1J Panel 00 / B 21 21 (4*ET)ET1780,ET1781,ET1782,ET1783

ETC 3 B 08.1R Panel 00 / B 22 22 (4*ET)ET1784,ET1785,ET1786,ET1787

ETC 3 B 08.1Z Panel 00 / B 23 23 (4*ET)ET1788,ET1789,ET1790,ET1791

ETC 4 B 01.1A Panel 00 / B 08 08 (4*ET)ET1920,ET1921,ET1922,ET1923

ETC 4 B 01.1J Panel 00 / B 09 09 (4*ET)ET1924,ET1925,ET1926,ET1927

ETC 4 B 01.1R Panel 00 / B 10 10 (4*ET)ET1928,ET1929,ET1930,ET1931

ETC 4 B 01.1Z Panel 00 / B 11 11 (4*ET)ET1932,ET1933,ET1934,ET1935

ETC 4 B 02.1A Panel 00 / B 12 12 (4*ET)ET1936,ET1937,ET1938,ET1939

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

Page 84: ET

84 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

5.3 TCSM3iTwo installation options of the third-generation Transcoder Submultiplexer are available: the TCSM3i for stand-alone installation option and the TCSM3i for combined BSC/TCSM installation option. The TCSM3i for stand-alone installation option always has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does not have a cabling cabinet.

5.3.1 TCSM3i for stand-alone installation optionIn the TCSM3i for stand-alone installation option, the cabling cabinet is always mounted to the TCSA cabinet. Balanced cabling panel is default, whereas the unbalanced is optional and must be ordered separately.

E1 (PCM) unbalanced trunk cable panel (CPETC-F)The unbalanced connector panels for the TCSM3i are shown in the following table.

ETC 4 B 02.1J Panel 00 / B 13 13 (4*ET)ET1940,ET1941,ET1942,ET1943

ETC 4 B 02.1R Panel 00 / B 14 14 (4*ET)ET1944,ET1945,ET1946,ET1947

ETC 4 B 02.1Z Panel 00 / B 15 15 (4*ET)ET1948,ET1949,ET1950,ET1951

ETC 4 B 03.1A Panel 00 / B 00 00 (4*ET)ET1952,ET1953,ET1954,ET1955

ETC 4 B 03.1J Panel 00 / B 01 01 (4*ET)ET1956,ET1957,ET1958,ET1959

ETC 4 B 03.1R Panel 00 / B 02 02 (4*ET)ET1960,ET1961,ET1962,ET1963

ETC 4 B 03.1Z Panel 00 / B 03 03 (4*ET)ET1964,ET1965,ET1966,ET1967

ETC 4 B 04.1A Panel 00 / B 04 04 (4*ET)ET1968,ET1969,ET1970,ET1971

ETC 4 B 04.1J Panel 00 / B 05 05 (4*ET)ET1972,ET1973,ET1974,ET1975

ETC 4 B 04.1R Panel 00 / B 06 06 (4*ET)ET1976,ET1977,ET1978,ET1979

ETC 4 B 04.1Z Panel 00 / B 07 07 (4*ET)ET1980,ET1981,ET1982,ET1983

ETC/GTIC cartridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-E panel through this cable

Corresponding external ET numbers

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

Page 85: ET

DN70617303Issue 1-0

85

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

Recommended cable type for E1 coaxial trunk cables is CPRD. See the following table and figure.

Figure 18 CPRD cable assembly (panel end connector mounted)

Equipping orderThe cabling cabinet is used with the TCSM3i for stand-alone installation option.

The D-connector in the unbalanced panels is shown in the following figure and the equipping order in the cabling cabinet is presented in the following table.

Panel number

Connector panel

0 CPETC-F

1 CPBP

2 CPBP

3 CPBP

4 CPETC-F

Table 37 Unbalanced connector panels for the TCSM3i

Cable type Filotex ET 267 380

Cable connector D37 connector body, type FCI DC8W8PA00; or ITT Cannon DCM-8W8P-A197

Coaxial inserts Rosenberger 55S101-302E2; IMS 307.23.2415.421

Table 38 Recommended cable type for E1 coaxial trunk cables (CPRD)

A1 A8

DN99257685

Page 86: ET

86 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

Page 87: ET

DN70617303Issue 1-0

87

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

Figure 19 D-connector

ETC car-tridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-F panel through this cable

Coaxial insert pairs of the Multicoaxial front ports used by

ETC 0 B 01.1A Panel 0 / B 00 00 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 01

ETC 0 B 01.1J Panel 0 / B 01 01 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 02

ETC 0 B 01.1R Panel 0 / B 02 02 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 03

ETC 0 B 01.1Z Panel 0 / B 03 03 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 04

ETC 1 B 01.1A Panel 0 / B 04 04 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 05

ETC 1 B 01.1J Panel 0 / B 05 05 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 06

ETC 1 B 01.1R Panel 0 / B 06 06 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 07

ETC 1 B 01.1Z Panel 0 / B 07 07 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 08

ETC 2 B 01.1A Panel 0 / B 08 08 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 09

ETC 2 B 01.1J Panel 0 / B 09 09 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 10

ETC 2 B 01.1R Panel 0 / B 10 10 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 11

ETC 2 B 01.1Z Panel 0 / B 11 11 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 12

ETC 1 B 02.1A Panel 0 / B12 12 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 13

ETC 1 B 02.1J Panel 0 / B13 13 (4*ET) A-interf. PCM1-4/ TR3 in TC2C0 slot 14

ETC 1 B 02.1R Panel 0 / B14 14 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 15

ETC 1 B 02.1Z Panel 0 / B15 15 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 16

ETC 0 B 02.1A Panel 0 / B16 16 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 01

ETC 0 B 02.1J Panel 0 / B17 17 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 02

ETC 0 B 02.1R Panel 0 / B18 18 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 03

ETC 0 B 02.1Z Panel 0 / B19 19 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 04

ETC 1 B 03.1A Panel 0 / B20 20 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 05

ETC 1 B 03.1J Panel 0 / B21 21 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 06

ETC 1 B 03.1R Panel 0 / B22 22 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 07

ETC 1 B 03.1Z Panel 0 / B23 23 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 08

ETC 2 B 02.1A Panel 0 / B24 24 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 09

ETC 2 B 02.1J Panel 0 / B25 25 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 10

ETC 2 B 02.1R Panel 0 / B26 26 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 11

ETC 2 B 02.1Z Panel 0 / B27 27 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 12

ETC 1 B 04.1A Panel 0 / B28 28 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 13

ETC 1 B 04.1J Panel 0 / B29 29 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 14

ETC 1 B 04.1R Panel 0 / B30 30 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 15

Table 39 Unbalanced panels in cabling cabinet - A-interface

Page 88: ET

88 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

ETC 1 B 04.1Z Panel 0 / B31 31 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 16

ETC 0 B 03.1A Panel 0 / B32 32 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 01

ETC 0 B 03.1J Panel 0 / B33 33 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 02

ETC 0 B 03.1R Panel 0 / B34 34 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 03

ETC 0 B 03.1Z Panel 0 / B35 35 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 04

ETC 1 B 05.1A Panel 0 / B36 36 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 05

ETC 1 B 05.1J Panel 0 / B37 37 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 06

ETC 1 B 05.1R Panel 0 / B38 38 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 07

ETC 1 B 05.1Z Panel 0 / B39 39 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 08

ETC 2 B 03.1A Panel 0 / B40 40 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 09

ETC 2 B 03.1J Panel 0 / B41 41 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 10

ETC 2 B 03.1R Panel 0 / B42 42 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 11

ETC 2 B 03.1Z Panel 0 / B43 43 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 12

ETC 1 B 06.1A Panel 0 / B44 44 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 13

ETC 1 B 06.1J Panel 0 / B45 45 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 14

ETC 1 B 06.1R Panel 0 / B46 46 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 15

ETC 1 B 06.1Z Panel 0 / B47 47 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 16

ETC 0 B 04.1A Panel 0 / B48 48 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 01

ETC 0 B 04.1J Panel 0 / B49 49 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 02

ETC 0 B 04.1R Panel 0 / B50 50 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 03

ETC 0 B 04.1Z Panel 0 / B51 51 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 04

ETC 1 B 07.1A Panel 0 / B52 52 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 05

ETC 1 B 07.1J Panel 0 / B53 53 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 06

ETC 1 B 07.1R Panel 0 / B54 54 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 07

ETC 1 B 07.1Z Panel 0 / B55 55 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 08

ETC 2 B 04.1A Panel 0 / B56 56 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 09

ETC 2 B 04.1J Panel 0 / B57 57 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 10

ETC 2 B 04.1R Panel 0 / B58 58 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 11

ETC 2 B 04.1Z Panel 0 / B59 59 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 12

ETC 1 B 08.1A Panel 0 / B60 60 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 13

ETC 1 B 08.1J Panel 0 / B61 61 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 14

ETC 1 B 08.1R Panel 0 / B62 62 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 15

ETC 1 B 08.1Z Panel 0 / B63 63 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 16

ETC car-tridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-F panel through this cable

Coaxial insert pairs of the Multicoaxial front ports used by

Table 39 Unbalanced panels in cabling cabinet - A-interface (Cont.)

Page 89: ET

DN70617303Issue 1-0

89

Connector Panels and External Cables in Flexi BSC and TCSM3i

E1 (PCM) unbalanced trunk cable panels (CPETC-Eand CPETC-F)

Id:0900d8058049ecb0

ETC 0 B 05.1A Panel 4 / B00 00 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 01

ETC 0 B 05.1J Panel 4 / B01 01 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 02

ETC 0 B 05.1R Panel 4 / B02 02 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 03

ETC 0 B 05.1Z Panel 4 / B03 03 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 04

ETC 2 B 05.1A Panel 4 / B04 04 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 05

ETC 2 B 05.1J Panel 4 / B05 05 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 06

ETC 2 B 05.1R Panel 4 / B06 06 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 07

ETC 2 B 05.1Z Panel 4 / B07 07 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 08

ETC 0 B 06.1A Panel 4 / B08 08 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 09

ETC 0 B 06.1J Panel 4 / B09 09 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 10

ETC 0 B 06.1R Panel 4 / B10 10 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 11

ETC 0 B 06.1Z Panel 4 / B11 11 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 12

ETC 2 B 06.1A Panel 4 / B12 12 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 13

ETC 2 B 06.1J Panel 4 / B13 13 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 14

ETC 2 B 06.1R Panel 4 / B14 14 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 15

ETC 2 B 06.1Z Panel 4 / B15 15 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 16

ETC 0 B 07.1A Panel 4 / B16 16 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 01

ETC 0 B 07.1J Panel 4 / B17 17 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 02

ETC 0 B 07.1R Panel 4 / B18 18 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 03

ETC 0 B 07.1Z Panel 4 / B19 19 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 04

ETC 2 B 07.1A Panel 4 / B20 20 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 05

ETC 2 B 07.1J Panel 4 / B21 21 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 06

ETC 2 B 07.1R Panel 4 / B22 22 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 07

ETC 2 B 07.1Z Panel 4 / B23 23 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 08

ETC 0 B 08.1A Panel 4 / B24 24 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 09

ETC 0 B 08.1J Panel 4 / B25 25 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 10

ETC 0 B 08.1R Panel 4 / B26 26 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 11

ETC 0 B 08.1Z Panel 4 / B27 27 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 12

ETC 2 B 08.1A Panel 4 / B28 28 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 13

ETC 2 B 08.1J Panel 4 / B29 29 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 14

ETC 2 B 08.1R Panel 4 / B30 30 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 15

ETC 2 B 08.1Z Panel 4 / B31 31 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 16

ETC car-tridge

From GT4C-A connector position

To panel / connector position

Multicoaxial front ports in CPETC-F panel through this cable

Coaxial insert pairs of the Multicoaxial front ports used by

Table 39 Unbalanced panels in cabling cabinet - A-interface (Cont.)

Page 90: ET

90 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d8058049ecb0

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)

5.3.2 TCSM3i for combined BSC/TCSM installation optionThe cabling cabinet is not used with the TCSA cabinet in the TCSM3i for combined BSC/TCSM installation option. Instead, the optical cabling from the front connectors of the ETS2 plug-in units is routed out of the cabinet through the CPGO at the cabinet top.

From car-tridge

TR3 unit slot From ET16 slot and con-nector position

ET panel / front ports through this cable

TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 32 (4*ET)

TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 33 (4*ET)

TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 34 (4*ET)

TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 35 (4*ET)

TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 36 (4*ET)

TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 37 (4*ET)

TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 38 (4*ET)

TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 39 (4*ET)

TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 40 (4*ET)

TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 41 (4*ET)

TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 42 (4*ET)

TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 43 (4*ET)

TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 44 (4*ET)

TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 45 (4*ET)

TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 46 (4*ET)

TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 47 (4*ET)

TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 48 (4*ET)

TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 49 (4*ET)

TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 50 (4*ET)

TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 51 (4*ET)

TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 52 (4*ET)

TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 53 (4*ET)

TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 54 (4*ET)

TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 55 (4*ET)

Notes

*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C cartridge is used for transcoder connections of one BSC.

Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used for transcoder connections of two BSCs (one half of the TC2C cartridge for one BSC and the other half for the other BSC).

Table 40 Unbalanced panels in cabling cabinet - Ater-interface

Page 91: ET

DN70617303Issue 1-0

91

Connector Panels and External Cables in Flexi BSC and TCSM3i

Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)

Id:0900d805804ab823

6 Roof panel with LAN, LPT/VDU, and synchro-nisation and alarm interfaces (CPRJ45-A)The CPRJ45-A panel is located in the middle hole at the BSCC cabinet top and it can be installed without the RACP adapter. The CPRJ45-A provides interfaces for 100 Mbit/s and 1 Gbit/s LAN uplinks, LPTs and VDUs, incoming external synchronisation signals, and inputs and outputs for external alarms.

Figure 20 Panel CPRJ45-A with LAN, alarm, LPT/VDU, and synchronisation inter-faces - seen from the front of the cabinet

The various interfaces are presented in the following sections:

• LAN interfaces • External alarm cabling • LPT/VDU interfaces • External synchronisation cabling

6.1 LAN interfacesBoth 1000Base-Sx LAN interfaces (ports 04 to 07, 12 to 15) for 1 Gbit/s uplinks and 10/100/1000Base-T/Tx LAN interfaces (ports 00 to 03, 08 to 11) for 10/100 Mbit/s and 1 Gbit/s copper uplinks in CPRJ45-A panel are used.

For more information, see

• 1 Gbit/s optical uplink LAN cables

LAN INTERFACES

LPT/VDU INTERFACESEXT SYNC ININTERFACES EXT AL INTERFACES

DN0626528

06 07

14 15

00

Tx Rx Tx Rx

01

08 09

02

10

03

11

18 19

22 23

ASYMM 1CLS 0,1

28

ASYMM 0CLS 0,1

20

EXT AL OUTPUT

CURRENT-CONTROLLEDAL INPUTS

LPT 0 VDU 0SYMM 0CLS 0, 1

VDU 1 VDU 2 VDU 2 LPT 2

B A

10/100/1000Base-T/Tx uplinks 1000Base-Sx uplinks

16

(V.24)

17

(V.24)

24

(V.24)

27

(V.11)

Tx RxTx Rx

Tx Rx Tx RxTx RxTx Rx

12 13

0504

24

(V.24)

26

(V.11)

SYMM 1CLS 0, 1

EXT AL INPUT

21

CL

AS

S1

LA

SE

RP

RO

DU

CT

IEC

/EN

60825

-1

Page 92: ET

92 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ab823

Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)

• 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cables

6.1.1 1 Gbit/s optical uplink LAN cablesThe Duplex LC connectors (04-07 and 12-15) in the connector panel CPRJ45-A are reserved for 1 Gbit/s optical uplink LAN cables. The optical uplink LAN interfaces in the CPRJ45-A panel are cabled to the front connectors of Ethernet Switch plug-in units using CLCS cables.

The following figure presents optical LC connectors.

Figure 21 Optical LC connectors, straight type

The following table presents the main characteristics of the optical cables and connec-tors.

The cables and the connectors should meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70 and the requirements of the FCC Part 68.

6.1.2 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cablesThe RJ45 connectors (00 to 03 and 08 to 11) in the connector panel CPRJ45-A are reserved for 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cabling. The uplink LAN inter-faces in the CPRJ45-A panel are cabled to the front connectors of Ethernet Switch plug-in units.

The cable types available for external 10/100 Mbits/1Gbits uplink cabling are the follow-ing:

• CNIX (cross-connected cable); connector type RJ45 modular connector (8-pole) • CNI (straight-connected cable); connector type RJ45 modular connector (8-pole)

The pin configuration in 10/100 Mbit/s use of the CNIX cable connector is presented in the following table.

Fibre cable mate-rial:

62.5/125 µm multimode fibre

Straight connec-tors:

Duplex LC, according to GR-326 , IEC 60874

30 5

DN70631285

Dustcaps to LCconnectors

B

Connector 1 Connector 2

Signal at CPRJ45

Colour Remarks

1 3 TX+ Orange/White Transmit (Tx)

2 6 TX- Orange Transmit (Tx)

Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-nected cable)

Page 93: ET

DN70617303Issue 1-0

93

Connector Panels and External Cables in Flexi BSC and TCSM3i

Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)

Id:0900d805804ab823

The pin configuration in 1 Gbit/s use of the CNIX cable connector is presented in the fol-lowing table.

The pin configuration in 10/100 Mbit/s use of the CNI cable connector is presented in the following table.

3 1 RX+ White/Green Receive (Rx)

6 2 RX- Green Receive (Rx)

4 7 Blue

5 8 White/Blue

7 4 White/Brown

8 5 Brown

Connector 1

Connector 2

Signal at CPRJ45

Colour Remarks

1 3 BI_DA+ Orange/White Transmit (Tx)

2 6 BI_DA- Orange Transmit (Tx)

3 1 BI_DB+ White/Green Receive (Rx)

6 2 BI_DB- Green Receive (Rx)

4 7 BI_DC+ Blue

5 8 BI_DC- White/Blue

7 4 BI_DD+ White/Brown

8 5 BI_DD- Brown

Table 42 CNIX cable connector, pin configuration in 1 Gbit/s use (cross-connected cable)

Connector 1, 2 Signal at CPRJ45-A

Colour Remarks

1 RX+ Orange/White Receive positive (Rx)

2 RX- Orange Receive negative (Rx)

3 TX+ White/Green Transmit positive (Tx)

4 Blue

5 White/Blue

Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-nected cable)

Connector 1 Connector 2

Signal at CPRJ45

Colour Remarks

Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-nected cable) (Cont.)

Page 94: ET

94 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ab823

Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)

The pin configuration in 1 Gbit/s use of the CNI cable connector is presented in the fol-lowing table.

The main characteristics of 10/100 Mbit/s /1 Gbit/s copper LAN cables are presented in the following table.

The LAN interfaces complying with the IEEE 802.3 standard for Ethernet serial inter-faces are of 10 Base-T and 100 Base-TX.

For more information, see Requirement specifications for external cables of M98 mechanics BSC3i and TCSM3i equipment.

6 TX- Green Transmit negative (Tx)

7 White/Brown

8 Brown

Connector 1, 2 Signal at CPRJ45-A

Colour Remarks

1 BI_DB+ Orange/White Bi-rectional positive

2 BI_DB- Orange Bi-rectional negative

3 BI_DA+ White/Green Bi-rectional positive

4 BI_DD+ Blue Bi-rectional positive

5 BI_DD- White/Blue Bi-rectional negative

6 BI_DA- Green Bi-rectional negative

7 BI_DC+ White/Brown Bi-rectional positive

8 BI_DC- Brown Bi-rectional negative

Table 44 CNI cable connector, pin configuration in 1 Gbit/s use (straight-connected cable)

Cable type: 4 pairs, twisted, shielded (S-FTP), Cat. 5 E or better, AWG24/26

Cable connector: Shielded RJ45 modular connector (8-pole), Cat. 5 E or better

Table 45 Recommended cable types for LAN cables (CNI and CNIX)

Connector 1, 2 Signal at CPRJ45-A

Colour Remarks

Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-nected cable) (Cont.)

Page 95: ET

DN70617303Issue 1-0

95

Connector Panels and External Cables in Flexi BSC and TCSM3i

Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)

Id:0900d805804ab823

6.2 External alarm cablingThe CPRJ45-A panel accommodates two D25 connectors, one (21) for external alarm inputs and one (22) for external alarm outputs. There is also one D9 connector (23) for voltage and current-controlled alarm inputs. The CPRJ45-A is located in the middle hole at the equipment cabinet top.

The external alarm cabling connectors are shown in the following table.

External alarm output signals - CNDE cableExternal Alarm output signals at the CPRJ45-A panel and configurations of CNDE cable with D25 connectors are presented in the following table.

Connector Cable, Connector Cable type

21 CYR, 25-pin D-connector, male. Other end has no connector

Milliflex3 SH AWG26/15 pairs

22 CNDE, two 25-pin D-connec-tors, male. Other end only par-tially connected

Milliflex3 SH AWG26/15 pairs

23 CYV 9-pin D-connector, male. Other end has no connector

Milliflex3 SH AWG26/8 pairs

Table 46 External alarm cabling connectors in the CPRJ45-A panel

Pin Alarms CNDE CNDE CNDC

CPRJ45-A panel, connec-tor 22

Connector 22 (EXT AL OUTPUT

Connector 1 Colour Connector 2

1 AEO0 1 Blue/White 1 (EXAU-A)

2 AEO1 2 White/Blue 3 (EXAU-A)

3 AEO2 3 Orange/White

5 (EXAU-A)

4 AEO3 4 White/Orange

7 (EXAU-A)

5 AEO4 5 Green/White 9 (EXAU-A)

6 AEO5 6 White/Green 11 (EXAU-A)

7 AEO6 7 Brown/White 13 (EXAU-A)

8 AEO7 8 White/Brown 15 (EXAU-A)

9 AEO8 9 Grey/White 17 (EXAU-A)

10 AEO9 10 White/Grey 19 (EXAU-A)

11 AE10 11 Blue/Yellow 21 (EXAU-A)

12 AE11 12 Yellow/Blue 23 (EXAU-A)

13 AE12 13 Orange/Yel-low

nc

Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable with D25 connectors

Page 96: ET

96 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ab823

Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)

Alarms AEO0-AEO11 are connected directly to the EXAU-A with cable CNDE. All alarms AEO0-AEO15 can be connected to the cross connection (DDF) with cable CNDE (the other cable end, connector 2, cut off).

Four lengths of CNDE cable are available (ID codes presented):

• 5 m: C106809 • 10 m: C106819 • 20 m: C108435

14 AE13 14 Yel-low/Orange

nc

15 AE14 15 Green/Yellow nc

16 AE15 16 Yellow/Green nc

17 - 17 Brow/Yellow nc

18 - 18 Yellow/Brown nc

19 - 19 Grey/Yellow nc

20 - 20 Yellow/Grey nc

21 - 21 Blue/Violet nc

22 - 22 Violet/Blue nc

23 - 23 Orange/Vio-let

nc

24 - 24 Vio-let/Orange

nc

25 GND 25 Green/Violet 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 25

- - nc Violet/Green nc

- - nc Brow/Violet nc

- - nc Violet/Brown nc

- - nc Grey/Violet nc

- - nc Violet/Grey nc

- - 25 Connector hood

Screen wire Connector hood

Hood GND Connector hood

Cable shield Connector hood

Notes

AEO = External alarm output signal

GND = Ground signal

Pin Alarms CNDE CNDE CNDC

CPRJ45-A panel, connec-tor 22

Connector 22 (EXT AL OUTPUT

Connector 1 Colour Connector 2

Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable with D25 connectors (Cont.)

Page 97: ET

DN70617303Issue 1-0

97

Connector Panels and External Cables in Flexi BSC and TCSM3i

Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)

Id:0900d805804ab823

• 50 m: C107185

Voltage controlled external alarm inputs - alarm cable CYR

Pin; Alarms; Alarm cable CYR;

Alarm cable CYR;

CPRJ45-A panel, connec-tor 21

Connector 21 (Voltage and current-controlled EXT AL INPUT)

Pin in Connector 1

Colour

1 AEI0 1 Blue/White

2 AEI1 2 White/Blue

3 AEI2 3 Orange/White

4 AEI3 4 White/Orange

5 AEI4 5 Green/White

6 AEI5 6 White/Green

7 AEI6 7 Brown/White

8 AEI7 8 White/Brown

9 AEI8 9 Grey/White

10 AEI9 10 White/Grey

11 AEI10 11 Blue/Yellow

12 AEI11 12 Yellow/Blue

13 AEI12 13 Orange/Yellow

14 AEI13 14 Yellow/Orange

15 AEI14 15 Green/Yellow

16 AEI15 16 Yellow/Green

17 AEI16 17 Brown/Yellow

18 AEI17 18 Yellow/Brown

19 AEI18 19 Grey/Yellow

20 AEI19 20 Yellow/Grey

21 AEI20 21 Blue/Purple

22 AEI21 22 Purple/Blue

23 AEI22 23 Orange/Purple

24 AEI23 24 Purple/Orange

25 GND 25 Green/Violet

- - nc Violet/Green

- - nc Brown/Violet

- - nc Violet/Brown

- - nc Grey/Violet

Table 48 Signals on panel connector 21 (Voltage and current-controlled AL inputs, AEIx)

Page 98: ET

98 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ab823

Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)

Voltage controlled external alarm input signals are connected from MDF to CPRJ45-A panel using CYR cable. Three lengths are available (CS codes presented):

• 35 m: CS73131.35 • 50 m: CS73131.50 • 70 m: CS73131.70

24 external voltage controlled alarm inputs can be connected to Flexi BSC using the CYR cable.

Current-controlled external alarm inputs

- - nc Violet/Grey

- - 25 Connector hood

Screen wire

Hood GND Connector hood Cable shield

Note

AEI = Voltage controlled external alarm input signal

Pin; Alarms; Alarm cable CYV;

Alarm cable CYV;

CPRJ45-A panel, connec-tor 23

Connector 23 (Voltage and current-controlled EXT AL INPUT)

Pin in Connector 1

Colour

1 ALS0 1 Blue/White

2 ALS1 2 White/Blue

3 ALS2 3 Orange/White

4 ALS3 4 White/Orange

5 ALS4 5 Green/White

6 ALS5 6 White/Green

7 - 7 Brown/White

8 - 8 White/Brown

9 GND 9 Grey/White

- - nc White/Grey

- - nc Blue/Yellow

Table 49 Signals on panel connector 23 (current-controlled ALS inputs)

Pin; Alarms; Alarm cable CYR;

Alarm cable CYR;

CPRJ45-A panel, connec-tor 21

Connector 21 (Voltage and current-controlled EXT AL INPUT)

Pin in Connector 1

Colour

Table 48 Signals on panel connector 21 (Voltage and current-controlled AL inputs, AEIx) (Cont.)

Page 99: ET

DN70617303Issue 1-0

99

Connector Panels and External Cables in Flexi BSC and TCSM3i

Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)

Id:0900d805804ab823

Current-controlled external alarm input signals are connected from MDF to CPRJ45-A panel by using the CYV cable.

One length of the cable is available (ID code presented): 20 m (C72239).

Six external current-controlled alarm inputs can be connected to the Flexi BSC by using the CYV cable.

Connections to external alarm unit EXAU-AA special lamp panel (External Alarm Unit EXAU-A) can be employed for the indication of alarms.

Indicator lights have been connected to six incoming alarms of EXAU-A. In the EXAU-A, a buzzer that can be connected to any alarm is available.

Using CNDE cable, the EXAU-A can be directly connected to D25-connector 22 of the CPRJ45-A panel or through the digital distribution frame (DDF or cross connection) that connects the alarm cables coming from the network element. When the alarms are routed through the digital distribution frame (DDF) the CNDE cable is cut and the wires are connected to the cross connection.

The complete CNDE cable is available in lengths 5, 10, 20 and 50 m. The maximum distance between the EXAU-A panel and the network element equipment it is connected to is 200 m (650ft.).

General requirements for external alarm cable CNDE are presented in the following table.

- - nc Yellow/Blue

- - nc Orange/Yellow

- - nc Yellow/Orange

- - nc Green/Yellow

- - nc Yellow/Green

- - 9 Connector hood Screen wire

Hood GND Connector hood Cable shield

Note

ALS = current-controlled external alarm input signal

Cable type: 12 pairs, twisted, shielded, cross section 0.4 mm2, Milliflex3 SH AWG26/8 pairs

Cable connector: 25-pin D connector (male/female)

Table 50 General requirements for external alarm cable CNDE

Pin; Alarms; Alarm cable CYV;

Alarm cable CYV;

CPRJ45-A panel, connec-tor 23

Connector 23 (Voltage and current-controlled EXT AL INPUT)

Pin in Connector 1

Colour

Table 49 Signals on panel connector 23 (current-controlled ALS inputs) (Cont.)

Page 100: ET

100 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ab823

Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)

The EXAU-A has also a second D25 connector which makes is possible to chain several alarm units so that the alarms can be displayed on more than one unit. See figure Instal-lation of the EXAU-A; mounting on the wall, cabling, and setting the buzzer jumpers.

Figure 22 Installation of the EXAU-A; mounting on the wall, cabling, and setting the buzzer jumpers

The colours of the alarm signals are shown in the following table.

Colour Position Signal Alarm

Red (1) Uppermost (AL00) Alarm 1

Yellow (2) (AL01) Alarm 2

Green (3) (AL02) Alarm 3

Red (4) (AL03) Alarm 4

Yellow (5) (AL04) Alarm 5

Blue (6) Lowermost (AL05) Alarm 6

140

134

DN068749

CAUTION 48V

J1

GND

1AL00 -

2AL01 -

3AL02 -

4AL03 -

5AL04 -

6AL05 -

7

8

ON

BUZZER SELECTSW1

Alarm 1AL00Alarm 2AL01Alarm 3AL02Alarm 4AL03Alarm 5AL04Alarm 6AL05 Test

Buzzer Reset

Silent Mode

2

3

3

2

5

SW1

J1F1

SW2

LS1

4

1

6

Base

PCB

PCB

Cover

Page 101: ET

DN70617303Issue 1-0

101

Connector Panels and External Cables in Flexi BSC and TCSM3i

Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)

Id:0900d805804ab823

6.3 VDU/LPT peripheral cabling (LPT/VDU interfaces)The CPRJ45-A panel accommodates six RJ45 connectors for the following VDU and LPT interfaces:

• port 16 for LPT 0 (V.24) • port 17 for VDU 0 (V.24) • ports 24 and 25 for VDU1 (V.24) and VDU2 (V.24) • ports 26 and 27 for VDU2 (V.11) and LPT2 (V.11).

Each connector provides access to one interface of visual display unit / PC or printer provided by the OMU (SERO-B). Pin configurations for connectors (16 and 17, and 24 to 27) providing the VDU/LPT interfaces are listed in Table V.24/V.11 cable connector in the CPRJ45-A panel, pin configuration.

The VDU can be connected to the CPRJ45-A panel by using the CNM cable, which is a CNI-type cable provided with an RJ45 connector and a D9 connector. The LPT printer can be connected to the CPRJ45-A panel using the CNP cable, which is a CNI-type cable provided with an RJ45 connector and a D25 connector. See the following figure.

Pin Signal (V.24) Signal (V.11) Colour

1 DTR TxD+ Orange/White

2 TxD TxD- White/Orange

3 GND RxD+ Green/White

4 GND Blue/White

5 RxD White/Blue

6 DSR RxD- Green/White

7 CTS Brown/White

8 RTS White/Brown

Table 51 V.24/V.11 cable connector in the CPRJ45-A panel, pin configuration

Page 102: ET

102 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ab823

Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)

Figure 23 Peripheral cables; CNM for VDU and CNP for LPT

Recommended cable types for V.24/V.11 cables (CNI) are shown in the following table.

The cable and the connector meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The connector also meets the require-ments of the FCC Part 68.

Pos. numberConn. RJ45F

Pos. numberConn. DB25M

Wire colour

1 (DTR)

2 (TxD)

3 (GND)

4 (GND)

5 (RxD)

6 (DSR)

7 (CTS)

8 (RTS)

6 (DSR)

3 (RxD)

2 (TxD)

20 (DTR)

4 (RTS)

5 (CTS)

Conn. hood Conn. hood

Pos. numberConn. RJ45F

Pos. numberConn. DE9FWire colour

1 (DTR)

2 (TxD)

3 (GND)

4 (GND)

5 (RxD)

6 (DSR)

7 (CTS)

8 (RTS)

orange/white

orange

blue

white/blue

green

white/brown

brown

6 (DSR)

2 RxD

3 (TxD)

4 (DTR)

7 (RTS)

8 (CTS)

Conn. hood shield Conn. hood

white/green

orange/white

orange

blue

white/blue

green

white/brown

brown

shield

white/green

1 (GND)1 (GND)

5 (signal GND) 7 (signal GND)

DN02237579

A

A

C

C

VIEW A-A

RJ45F(female)

VIEW C-C

RJ45F(female)

CMN-cable

CNP-cable

L

L

12

1DE9F

(female)

VIEW B-B

BB

DB25M(male)

32

1 1

2

3

POSITION NUMBER 1

UNC-40 male locking screws

USE CABLE OUTLETOPTIMISING BUSHING

VIEW D-D

1

D D

CONNECTION CNM-cable CONNECTION CNP-cable

Cable type 4 pairs, twisted, shielded (S-FTP), Cat. 5 E, AWG24/26

Cable connector Shielded RJ45 modular connector (8-pole), Cat. 5 E.

Table 52 Recommended cable types for V.24/V.11 cables (CNI)

Page 103: ET

DN70617303Issue 1-0

103

Connector Panels and External Cables in Flexi BSC and TCSM3i

Roof panel with LAN, LPT/VDU, and synchronisationand alarm interfaces (CPRJ45-A)

Id:0900d805804ab823

6.4 External synchronisation cabling (EXT SYNC interfaces)The CPRJ45-A panel accommodates two RJ45 connectors (18 SYMM0 and 19 SYMM1) for balanced (symmetric) synchronisation interfaces, and two BNC connectors (20 ASYMM0 and 28 ASYMM1) for coaxial, unbalanced interfaces.

Balanced (symmetric)The pin configuration for connectors 18 (SYMM0 CLS 0,1) and 19 (SYMM1 CLS 0,1), and colours for CNI cable connector are presented in the following table.

Recommended cable types for balanced synchronisation cable (CNI) are shown in the following table.

Pin Connector 18 (SYMM0CLS 0,1)

Connector 19 (SYMM1CLS 0,1)

Colour (CNI) Remarks

1 FS1A FS2A Orange/White Wire A of external fre-quency standard FS1 or FS2

2 FS1B FS2B White/Orange Wire B of external fre-quency standard FS1 or FS2

3 - - Green/White

Blue/White

White/Blue

Green/White

7 - - Brown/White

8 - - White/Brown

Connector hood

RSG1 RSG2 Ground signal

Notes

FS1A = Wire A of external frequency standard FS1

FS1B = Wire B of external frequency standard FS1

FS2A = Wire A of external frequency standard FS2

FS2B = Wire B of external frequency standard FS2

RSG1 = Ground signal

RSG2 = Ground signal

Table 53 The pin configuration for connectors 18 and 19

Cable type: 4 pairs, twisted, shielded (S-FTP), Cat. 5 E, AWG24/26

Cable connector: Shielded RJ45 modular connector (8-pole), Cat. 5 E.

Table 54 Recommended cable types for synchronisation cables (CNI)

Page 104: ET

104 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804ab823

Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A)

Unbalanced (asymmetric)The pin configuration for connectors 20 and 28 is shown in the following table.

Pin Signal / Connector 20 / ASYMM0 CLS0,1

Signal / Connector 28 / ASYMM1 CLS0,1

Centre wire FS1A FS2A

Cable sheath FS1B FS2B

Table 55 Pin configuration for connectors 20 and 28

Page 105: ET

DN70617303Issue 1-0

105

Connector Panels and External Cables in Flexi BSC and TCSM3i

Cabling panel with grounding outlets (CPGO)

Id:0900d8058048f55e

7 Cabling panel with grounding outlets (CPGO)The cabling panel with grounding outlets (CPGO) is installed at site at the BSCC cabinet top of the Flexi BSC. The CPGO is used for STM-1/OC-3 trunk cables and GigE Ethernet interface cables.

Figure 24 CPGO

The cables and the connectors meet the requirements of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70 as well as the requirements of the FCC Part 68.

Figure 25 Optical LC connectors, straight type

Main characteristics of optical cables and connectors are shown in the following tables.

For more information on the optical cables, see Requirement specifications for external cables of M98 mechanics Flexi BSC product family and TCSM3i.

Fibre cable material: 9/125 um singlemode fibre

Straight or angle connectors: Duplex LC, according to GR-326, IEC 60874

Table 56 Main characteristics of optical singlemode cables and connectors

Fibre cable material: 62.5/125 um multimode fibre

Straight or angle connectors: Duplex LC, according to GR-326, IEC 60874

Table 57 Main characteristics of optical multimode cables and connectors

CPGO

DN0626582

30 5

DN70631285

Dustcaps to LCconnectors

B

Page 106: ET

106 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804f3fcb

Requirement specifications for external cables of M98 mechanics Flexi BSC and TCSM3i

8 Requirement specifications for external cables of M98 mechanics Flexi BSC and TCSM3i

8.1 General requirements for connectors and cable materialsConnectors:

• Connectors and hoods of the connectors must be shielded • 1.25 mm, or 50 microinches (0.75 mm or 30 microinches, if 1.25 mm is not available)

gold plating on the contacts • UL94 V-0 materials

Cable material:

• Shielded construction, screening effectiveness > 60 dB at 1GHz • AWG 26 conductors • Continuous pair twisting on the twisted pair cables • Operating temperature 0 to 80°C • VW-1 materials

Optional:

• Halogen free materials (IEC 332-1 or IEC 332-3) • Grey colour (RAL 7036, if available)

8.2 Requirements for specified coaxial cable assemblies

8.2.1 E1 coaxial unbalanced PCM cable assembly

Cable:

• Multicoaxial cable (8 coax) with common braid • Impedance 75 ± 3 Ω • Maximum attenuation < 9dB/100 m at 10 MHz • Nominal capacitance: < 66 pF/m • Conductor resistance: < 365 Ω/km

Connectors:

• Coaxial connectors: SMB/50 Ω/straight type

8.2.2 Unbalanced (coaxial) external synchronisation cable assembly (CKB)

Cable:

• Coaxial (BT 3002) • Impedance 75 Ω ± 4 Ω • Attenuation: 4.4 dB/100 m at 5 MHz

Page 107: ET

DN70617303Issue 1-0

107

Connector Panels and External Cables in Flexi BSC and TCSM3i

Requirement specifications for external cables of M98mechanics Flexi BSC and TCSM3i

Id:0900d805804f3fcb

• Capacitance: < 66 pF/m

Connectors:

• BNC type

8.3 Requirements for specified twisted pair cable assemblies

8.3.1 10 Base-T /100 Base-TX / 1000Base-T/TX LAN cable assemblies (CNI and cross-connected LAN cable)

Cable:

• S-FTP • Category 5 E • Meets EIA/TIA 568-A standard

Connectors:

• RJ45

8.3.2 T1 (E1) balanced PCM cable assembly (CNIS)

Cable:

• Nominal impedance: 100 ± 15 Ω • Attenuation: < 4 dB/100 m at 1 MHz • Resistance: Maximum 151 Ω/km at 20°C • Crosstalk attenuation: > 70 dB at 150 kHz

Connectors:

• Shielded 8-pole plug RJ45

8.3.3 E1 balanced PCM cable assembly (CNIB)

Cable:

• Nominal impedance: 120 ± 15 Ω • Attenuation: < 4 dB/100 m at 1 MHz • Resistance: Maximum 151 Ω/km at 20°C • Crosstalk attenuation: > 70 dB at 150 kHz

Connectors:

• Shielded 8-pole plug RJ45

8.3.4 E1 balanced PCM cable assembly (CNIA)

Cable:

• Nominal impedance: 120 ± 15 Ω • Attenuation: < 4 dB/100 m at 1 MHz • Resistance: Maximum 151 Ω/km at 20°C

Page 108: ET

108 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804f3fcb

Requirement specifications for external cables of M98 mechanics Flexi BSC and TCSM3i

• Crosstalk attenuation: > 70 dB at 150 kHz

Connectors:

• Shielded 8-pole plug RJ45

8.3.5 Current and voltage-controlled alarm cable assembly (CNDC)

Cable:

• See General requirements

Connectors:

• 25-pin D-subminiature connector at both ends of the cable

8.3.6 Alarm cable (CNDE)

Cable:

• 10-pair • double shielded (foil and copper braid) • halogen-free jacket • differential impedance 100 Ω • AWG 26 conductors

Connectors:

• 25-pole male D-connectors

8.3.7 Alarm cable (CYV)

Cable:

• Milliflex3 SH AWG26/4 pairs

Connectors:

• male 9-pin D-connector at one end of the cable

8.3.8 Alarm cable (CYR)

Cable:

• See General requirements

Connectors:

• 25-pin D-subminiature connector at one end of the cable

8.3.9 Electrical performance requirements for X.25 cable assemblies

Cable:

• Linear resistance of the conductor: 151 Ω/km, maximum 20 °C • Nominal impedance: 100 ± 15 Ω • Attenuation: < 4 dB/100 m at 1 MHz

Page 109: ET

DN70617303Issue 1-0

109

Connector Panels and External Cables in Flexi BSC and TCSM3i

Requirement specifications for external cables of M98mechanics Flexi BSC and TCSM3i

Id:0900d805804f3fcb

• Capacitance between cores: 60 pF/m nominal • Phase delay time: 5.4 ms/km at 1 MHz • Crosstalk attenuation: > 50 dB at 150 kHz

V.24 cable assemblies (CLSC)Connectors:

• 25-pin D-subminiature connector • 2HM connector

V.35 cable assembly (CLRD) - S11.5Connectors:

• V.35 connector • D25 connector

V.35 cable assembly (CLRC)- S10 and S11Connectors:

• V.35 connector • 2HM connector

X.21 cable assemblies (CLTC)Connectors:

• 15-pin D-subminiature connector • 2 Hard Metric connector

8.3.10 Electrical performance requirements for optical LC cable assem-blies (multimode cable)

Fibre cable material

• 62,5/125 µm multi mode fibre • RoHS-compliance according to EU-directive • Attenuation 3.8 dB/km maximum at 850 nm wavelength, according to IEC 60793-1-

C1 • Duplex type • Halogen free material, according to IEC 60754-1 • Flammability UL VW-1 listed or UL94V-0 rated material • Fibre cables must be provided with a common secondary overall jacket, which is not

permitted to glide too loosely along fibre cables • Shape of cable jacket, circular, elliptical jacket can be used, if circular material is not

available • Cable outer diameter 6.6mm maximum • Minimum bending radius during installation 65 mm and in service 43mm, according

to IEC 60794-1-2E11A or similar standard • Crush resistance (briefly) > 500 N/cm, according to IEC 60794-1-E3

Crush resistance (continuous) > 100 N/cm • Orange jacket color, if orange is not available, gray color can be used • Operating temperature from 0 to 70°C

Page 110: ET

110 DN70617303Issue 1-0

Connector Panels and External Cables in Flexi BSCand TCSM3i

Id:0900d805804f3fcb

Requirement specifications for external cables of M98 mechanics Flexi BSC and TCSM3i

Connector 1 and connector 2

• TIA/EIA 604-10A • All requirements are for one connector • Duplex LC, according to GR-326 and IEC 60874 • RoHS-compliance according to EU-directive • Mating durability for 200 reconnects, insertion loss change < 0.2 dB • Insertion loss 0.5 dB maximum • SPC finish • Return loss > 20 dB • Flammability UL94V-0 • Zirconia ferrule • Beige color • Dust caps included • Operating temperature from 0 to 70°C • Efficiency of strain relief > 80N/termination

Cable support for LC connector 1

• Flammability UL94 V-0 • Straight flexible boot • RoHS-compliance according to EU-directive • Cable boot color gray/beige • Efficiency of strain relief > 50N/boot

Cable support for LC connector 2

• Flammability UL94 V-0 • 90° angle boot • RoHS-compliance according to EU-directive • Maximum installation length 70 mm • Cable boot color gray/beige • Efficiency of strain relief: > 20N/boot • Design should allow rotation of cable support

8.3.11 Electrical performance requirements for optical LC cable assem-blies (singlemode cable)

Cable material:

• 9/125 µm single mode fibre • RoHS-compliance according to EU-directive • Cut-off wavelength < 1260 nm, according to IEC 60793-1-C7B • Attenuation (buffered fiber):

= 0,50 dB/km at 1310 nm wavelengths, according to IEC 60793-1-C10 = 0,40 dB/km at 1550 nm wavelengths, according to IEC 60793-1-C10

• Cable must fulfill ITU-T G.652 for interface type STM-1 optical (ITU-T G.957, table 1) • Cable must fulfill ATM 155 Mb/s o Duplex type • Duplex type • Halogen free material, IEC 60754-1

Page 111: ET

DN70617303Issue 1-0

111

Connector Panels and External Cables in Flexi BSC and TCSM3i

Requirement specifications for external cables of M98mechanics Flexi BSC and TCSM3i

Id:0900d805804f3fcb

• Flammability UL VW-1 or UL94V-0 rated cable material • Fibre cables must be provided with a common secondary overall jacket, which is not

permitted to glide too loosely along fibre cables • Shape of cable jacket circular, elliptical jacket can be used, if the circular material is

not available • Cable outer diameter 6.6 mm maximum • Minimum bending radius during installation, 65 mm and in service 43 mm, according

to IEC 60794-1-2E11A or similar standard • Crush resistance (briefly) > 500 N/cm, according to IEC 60794-1-E3

Crush resistance (continuous) > 100 N/cm • Yellow jacket color • Operating temperature from 0 to 70°C

Connector 1 and connector 2

• All requirements are for one connector • Duplex LC, according to GR-326 and IEC 60874 • RoHS-compliance according to EU-directive • Mating durability for 200 reconnects, insertion loss change < 0.2 dB • Insertion loss < 0.3 dB • SPC finish • Return loss > 45 dB • Flammability UL94V-0 • Zirconia ferrule • Blue color • Dust caps included • Operating temperature from 0 to 70°C • Efficiency of strain relief > 80N

Cable supports for LC connector 1

• Flammability UL94V-0 • Straight flexible boot • RoHS-compliance according to EU-directive • Cable boot color gray/beige • Efficiency of strain relief > 50N/boot

Cable supports for LC connector 2

• Flammability UL94V-0 • 90° angle boot • RoHS-compliance according to EU-directive • Maximum installation length 70 mm • Cable boot color gray/beige • Efficiency of strain relief > 20N/boot • Design should allow rotation of cable support