Contact São Paulo Phone: +55 11 3084-1600 [email protected]Essential-5 cable. Version null Generated 5/29/17 - http://www.nexans.com.br Page 1 / 42 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. U/UTP and F/UTP constructions • In accordance with the newer standards for CAT 5e • It supports applications from class D up to 100MHz • Standards International ISO/IEC 11801 Description Padrões: Internacional : ISO/IEC 11801 Nacional : ANSI/TIA-568-C.2 e ANATEL Aplicação: A linha de cabos Essential-5 é a oferta de 100MHz padrão de Nexans. Fabricados e testados com a mais recente especificação da Categoria 5e definidos pelo padrão Internacional e norte-americana, eles são adequados para instalações de voz e dados com aplicações até 100 MHz. Design: Os cabos Essential-5 têm fios de cobre sólido 24 AWG e cumpri com a norma IEC 60228. Os cabos estão disponíveis em diversas cores em caixa ou em bobina, em PVC ou LSZH. Ambas as versões têm propriedades retardantes de chama de acordo com IEC 60332-1, UL1666 ou IEC 60332-3. Performance: Cabos Nexans Essential-5 estão em conformidade com os requisitos das normas Internacional, europeias, americanas e brasileira incluindo ISO / IEC 11801, IEC 61156-5, EN 50173, ANSI/TIA/EIA 568-C.2 e ABNT NBR 14565.
42
Embed
Essential-5 cable. - SolutionBox · Essential-5 cable. ESSENTIAL CAT5E F/UTP 4P 24AWG - CM Version null Generated 5/29/17 - Page 4 / 42 All drawings, designs, specifications ...
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Version null Generated 5/29/17 - http://www.nexans.com.br Page 1 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
U/UTP and F/UTP constructions•In accordance with the newer standards for CAT 5e•It supports applications from class D up to 100MHz•
Standards
International ISO/IEC 11801
Description
Padrões:Internacional : ISO/IEC 11801Nacional : ANSI/TIA-568-C.2 e ANATEL
Aplicação:A linha de cabos Essential-5 é a oferta de 100MHz padrão de Nexans.Fabricados e testados com a mais recente especificação da Categoria 5edefinidos pelo padrão Internacional e norte-americana, eles são adequados parainstalações de voz e dados com aplicações até 100 MHz.
Design:Os cabos Essential-5 têm fios de cobre sólido 24 AWG e cumpri com a normaIEC 60228.Os cabos estão disponíveis em diversas cores em caixa ou em bobina, em PVCou LSZH. Ambas as versões têm propriedades retardantes de chama de acordocom IEC 60332-1, UL1666 ou IEC 60332-3.
Performance:Cabos Nexans Essential-5 estão em conformidade com os requisitos das normasInternacional, europeias, americanas e brasileira incluindo ISO / IEC 11801, IEC61156-5, EN 50173, ANSI/TIA/EIA 568-C.2 e ABNT NBR 14565.
Version null Generated 5/29/17 - http://www.nexans.com.br Page 2 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Product List =Make to order, =In stock
Nexans ref. Name Type ofcable
Outersheath
Length(m)
Packaging Installationtype
N100.572x10ESSENTIAL CAT5E F/UTP 4P24AWG - CM
F/UTP PVC - CM 1000 Reel Indoor
N100.571x11ESSENTIAL CAT5E F/UTP 4P24AWG - CMX
F/UTP PVC - CMX 1000 Reel Indoor/Outdoor
N100.562x30ESSENTIAL CAT5E U/UTP 4P24AWG - CM
U/UTP PVC - CM 305 Box Indoor
N100.562x10ESSENTIAL CAT5E U/UTP 4P24AWG - CM
U/UTP PVC - CM 1000 Reel Indoor
N100.563x30ESSENTIAL CAT5E U/UTP 4P24AWG - CMR
U/UTP PVC - CMR 305 Box Indoor
N100.561x30ESSENTIAL CAT5E U/UTP 4P24AWG - CMX
U/UTP PVC - CMX 305 Box Indoor
N100.561x10ESSENTIAL CAT5E U/UTP 4P24AWG - CMX
U/UTP PVC - CMX 1000 Reel Indoor
N100.561231ESSENTIAL CAT5E U/UTP 4P24AWG - CMX
U/UTP PVC - CMX 305 Box Indoor/Outdoor
N100.561211ESSENTIAL CAT5E U/UTP 4P24AWG - CMX
U/UTP PVC - CMX 1000 Reel Indoor/Outdoor
N100.561100ESSENTIAL CAT5E U/UTP 4P24AWG - CMX - 100m
U/UTP PVC - CMX 100 Box Indoor
N100.561200ESSENTIAL CAT5E U/UTP 4P24AWG - CMX - Black
U/UTP PVC - CMX 100 Box Indoor
N100.561300ESSENTIAL CAT5E U/UTP 4P24AWG - CMX - Blue
Version null Generated 5/29/17 - http://www.nexans.com.br Page 3 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Essential-5 cable.ESSENTIAL CAT5E F/UTP 4P 24AWG - CM
Version null Generated 5/29/17 - http://www.nexans.com.br Page 4 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.572x10
The ESSENTIAL 5e F/UTP cables from Nexans were designed for applications that need an additional protection. Thiscable have an aluminum flexible tape involving the pairs and tinned conductors, which assures the grounding continuity.Your application is limited on the bandwidth of 100MHz, class D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analogical and digital communication for video and voice•Power Over Ethernet (PoE)•
Categoria 5E – F/UTP•Annealed bare copper conductor isolated by a high density polyethylenethermoplastic. The conductors (veins) are twisted and reunited, forming the 4pairs core. A flame retardant layer material is applied over the core.
•
Produced according to the RoHS standard,•PVC CM•Nominal diameter 24AWG (approximately 0,51mm)•
Essential-5 cable.ESSENTIAL CAT5E F/UTP 4P 24AWG - CM
Version null Generated 5/29/17 - http://www.nexans.com.br Page 5 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Dimensional characteristics
Outer Diameter 5.7 mm
Approximate weight 41 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 1000 m
Packaging Reel
Installation type Indoor
Electro magnetic interference resistance Yes
Category Cat. 5e
Fire retardant IEC 60332-3
Ambient dynamic operating temperature, range -20 .. 60 °C
Essential-5 cable.ESSENTIAL CAT5E F/UTP 4P 24AWG - CM
Version null Generated 5/29/17 - http://www.nexans.com.br Page 6 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Version null Generated 5/29/17 - http://www.nexans.com.br Page 7 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.571x11
The ESSENTIAL 5e F/UTP cables from Nexans were designed for applications that need an additional protection. Thiscable have an aluminum flexible tape involving the pairs and tinned conductors, which assures the grounding continuity.Your application is limited on the bandwidth of 100MHz, class D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analogical and digital communication for video and voice•Power Over Ethernet (PoE)•
Categoria 5E – F/UTP•Annealed bare copper conductor isolated by a high density polyethylenethermoplastic. The conductors (veins) are twisted and reunited, forming the 4pairs core. A flame retardant layer material is applied over the core.
•
Produced according to the RoHS standard,•PVC CMX•Nominal diameter 24AWG (approximately 0,51mm)•
Internal and external environment / Not aggressive•
Version null Generated 5/29/17 - http://www.nexans.com.br Page 8 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Dimensional characteristics
Outer Diameter 5 mm
Approximate weight 27 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 1000 m
Packaging Reel
Installation type Indoor/Outdoor
Electro magnetic interference resistance Yes
Category Cat. 5e
Fire retardant IEC 60332-1
Ambient dynamic operating temperature, range -20 .. 60 °C
Version null Generated 5/29/17 - http://www.nexans.com.br Page 9 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CM
Version null Generated 5/29/17 - http://www.nexans.com.br Page 10 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.562x30
The Nexans ESSENTIAL CAT5E Cables were designed for horizontal applications in sctructured cabling network to connectthe work are at the administration panel or interconnect panels managment. Its application is limited in 100MHz bandwith ,Class D.
Standards
International ISO/IEC 11801
Description
Application
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analog and digital communication for voice and video•Power Over Ethernet (PoE)
•
Design
Category 5E – U/UTP•Bare copper conductor annealed isolated by thermoplastic polyethylene high•
Produced according to RoHS normative.•PVC CM•Nominal diameter 24AWG (0.51mm approximately)•
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CM
Version null Generated 5/29/17 - http://www.nexans.com.br Page 11 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CM
Version null Generated 5/29/17 - http://www.nexans.com.br Page 12 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CM
Version null Generated 5/29/17 - http://www.nexans.com.br Page 13 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.562x10
Os cabos ESSENTIAL 5e UTP da Nexans foram projetados para aplicações horizontais em redes de cabeamentoestruturado para conectar a tomada do usuário com o painel de administração ou para interligação de painéis deadministração. Sua aplicação esta limitada na largura de banda de 100MHz, Classe D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Comunicação analógica e digital para vídeo e voz•Power Over Ethernet (PoE)•
Categoria 5E – U/UTP•Condutor de cobre nu recozido isolado por polietileno termoplástico de altadensidade. Os condutores (veias) são torcidos e reunidos formando o núcleode 4 pares. Sobre o núcleo é aplicada uma capa de material retardante achama.
•
Produzido de acordo com a normativa RoHS.• PVC CM• Diâmetro nominal 24AWG (0,51mm aproximadamente)•
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CM
Version null Generated 5/29/17 - http://www.nexans.com.br Page 14 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Dimensional characteristics
Outer Diameter 4.8 mm
Approximate weight 26.5 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 1000 m
Packaging Reel
Installation type Indoor
Category Cat. 5e
Electro magnetic interference resistance No
Fire retardant IEC 60332-3
Ambient dynamic operating temperature, range -20 .. 60 °C
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CM
Version null Generated 5/29/17 - http://www.nexans.com.br Page 15 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Version null Generated 5/29/17 - http://www.nexans.com.br Page 16 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.563x30
The Nexans ESSENTIAL 6 UTP cables were designed for horizontal applications in structured wiring networks to connectthe user’s socket with the administration panel or for the administrative panels interconnection. Your application is limited onthe bandwidth of 100MHz, class D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analogical and digital communication for video and voice•Power Over Ethernet (PoE)•
Category 5E – U/UTP•Annealed bare copper conductor isolated by a high density polyethylenethermoplastic. The conductors (veins) are twisted and reunited, forming the 4pairs core. A flame retardant layer material is applied over the core.
•
Produced according to the RoHS standard,• PVC CMR• Nominal diameter 24AWG (approximately 0,51mm)•
Version null Generated 5/29/17 - http://www.nexans.com.br Page 17 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Dimensional characteristics
Outer Diameter 4.8 mm
Approximate weight 26.5 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 305 m
Packaging Box
Installation type Indoor
Category Cat. 5e
Electro magnetic interference resistance No
Fire retardant UL 1666
Ambient dynamic operating temperature, range -20 .. 60 °C
Version null Generated 5/29/17 - http://www.nexans.com.br Page 18 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Version null Generated 5/29/17 - http://www.nexans.com.br Page 19 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.561x30
The Nexans ESSENTIAL 6 UTP cables were designed for horizontal applications in structured wiring networks to connectthe user’s socket with the administration panel or for the administrative panels interconnection. Your application is limited onthe bandwidth of 100MHz, class D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analogical and digital communication for video and voice•Power Over Ethernet (PoE)•
Category 5E – U/UTP•Annealed bare copper conductor isolated by a high density polyethylenethermoplastic. The conductors (veins) are twisted and reunited, forming the 4pairs core. A flame retardant layer material is applied over the core.
•
Produced according to the RoHS standard,• PVC CMX• Nominal diameter 24AWG (approximately 0,51mm)•
Version null Generated 5/29/17 - http://www.nexans.com.br Page 20 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Dimensional characteristics
Outer Diameter 4.8 mm
Approximate weight 26.5 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 305 m
Packaging Box
Installation type Indoor
Category Cat. 5e
Electro magnetic interference resistance No
Fire retardant IEC 60332-1
Ambient dynamic operating temperature, range -20 .. 60 °C
Version null Generated 5/29/17 - http://www.nexans.com.br Page 21 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Version null Generated 5/29/17 - http://www.nexans.com.br Page 22 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.561x10
The Nexans ESSENTIAL 6 UTP cables were designed for horizontal applications in structured wiring networks to connectthe user’s socket with the administration panel or for the administrative panels interconnection. Your application is limited onthe bandwidth of 100MHz, class D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analogical and digital communication for video and voice•Power Over Ethernet (PoE)•
Category 5E – U/UTP•Annealed bare copper conductor isolated by a high density polyethylenethermoplastic. The conductors (veins) are twisted and reunited, forming the 4pairs core. A flame retardant layer material is applied over the core.
•
Produced according to the RoHS standard,• PVC CMX• Nominal diameter 24AWG (approximately 0,51mm)•
Internal and external environment / Not aggressive•UV protection, ANATEL certification for internal/external environment.•
Version null Generated 5/29/17 - http://www.nexans.com.br Page 23 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Construction characteristics
Screen Unshielded
Dimensional characteristics
Outer Diameter 4.8 mm
Approximate weight 26.5 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 1000 m
Packaging Reel
Installation type Indoor
Category Cat. 5e
Electro magnetic interference resistance No
Fire retardant IEC 60332-1
Ambient dynamic operating temperature, range -20 .. 60 °C
Version null Generated 5/29/17 - http://www.nexans.com.br Page 24 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Version null Generated 5/29/17 - http://www.nexans.com.br Page 25 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.561231
The Nexans ESSENTIAL 6 UTP cables were designed for horizontal applications in structured wiring networks to connectthe user’s socket with the administration panel or for the administrative panels interconnection. Your application is limited onthe bandwidth of 100MHz, class D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analogical and digital communication for video and voice•Power Over Ethernet (PoE)•
Category 5E – U/UTP•Annealed bare copper conductor isolated by a high density polyethylenethermoplastic. The conductors (veins) are twisted and reunited, forming the 4pairs core. A flame retardant layer material is applied over the core.
•
Produced according to the RoHS standard,•PVC CMX•Nominal diameter 24AWG (approximately 0,51mm)•
Version null Generated 5/29/17 - http://www.nexans.com.br Page 26 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Construction characteristics
Screen Unshielded
Dimensional characteristics
Outer Diameter 4.8 mm
Approximate weight 26.5 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 305 m
Packaging Box
Installation type Indoor/Outdoor
Category Cat. 5e
Electro magnetic interference resistance No
Fire retardant IEC 60332-1
Ambient dynamic operating temperature, range -20 .. 60 °C
Version null Generated 5/29/17 - http://www.nexans.com.br Page 27 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Version null Generated 5/29/17 - http://www.nexans.com.br Page 28 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.561211
The Nexans ESSENTIAL 6 UTP cables were designed for horizontal applications in structured wiring networks to connectthe user’s socket with the administration panel or for the administrative panels interconnection. Your application is limited onthe bandwidth of 100MHz, class D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analogical and digital communication for video and voice•Power Over Ethernet (PoE)•
Category 5E – U/UTP•Annealed bare copper conductor isolated by a high density polyethylenethermoplastic. The conductors (veins) are twisted and reunited, forming the 4pairs core. A flame retardant layer material is applied over the core.
•
Produced according to the RoHS standard,•PVC CMX•Nominal diameter 24AWG (approximately 0,51mm)•
Version null Generated 5/29/17 - http://www.nexans.com.br Page 29 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Construction characteristics
Screen Unshielded
Dimensional characteristics
Outer Diameter 4.8 mm
Approximate weight 26.5 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 1000 m
Packaging Reel
Installation type Indoor/Outdoor
Category Cat. 5e
Electro magnetic interference resistance No
Fire retardant IEC 60332-1
Ambient dynamic operating temperature, range -20 .. 60 °C
Version null Generated 5/29/17 - http://www.nexans.com.br Page 30 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CMX - 100m
Version null Generated 5/29/17 - http://www.nexans.com.br Page 31 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.561100
The Nexans ESSENTIAL 6 UTP cables were designed for horizontal applications in structured wiring networks to connectthe user’s socket with the administration panel or for the administrative panels interconnection. Your application is limited onthe bandwidth of 100MHz, class D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analogical and digital communication for video and voice•Power Over Ethernet (PoE)•
Category 5E – U/UTP•Annealed bare copper conductor isolated by a high density polyethylenethermoplastic. The conductors (veins) are twisted and reunited, forming the 4pairs core. A flame retardant layer material is applied over the core.
•
Produced according to the RoHS standard,• PVC CMX• Nominal diameter 24AWG (approximately 0,51mm)•
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CMX - 100m
Version null Generated 5/29/17 - http://www.nexans.com.br Page 32 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Dimensional characteristics
Approximate weight 26.5 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 100 m
Packaging Box
Installation type Indoor
Category Cat. 5e
Electro magnetic interference resistance No
Fire retardant IEC 60332-1
Ambient dynamic operating temperature, range -20 .. 60 °C
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CMX - 100m
Version null Generated 5/29/17 - http://www.nexans.com.br Page 33 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CMX - Black
Version null Generated 5/29/17 - http://www.nexans.com.br Page 34 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.561200
The Nexans ESSENTIAL 6 UTP cables were designed for horizontal applications in structured wiring networks to connectthe user’s socket with the administration panel or for the administrative panels interconnection. Your application is limited onthe bandwidth of 100MHz, class D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analogical and digital communication for video and voice•Power Over Ethernet (PoE)•
Category 5E – U/UTP•Annealed bare copper conductor isolated by a high density polyethylenethermoplastic. The conductors (veins) are twisted and reunited, forming the 4pairs core. A flame retardant layer material is applied over the core.
•
Produced according to the RoHS standard,• PVC CMX• Nominal diameter 24AWG (approximately 0,51mm)•
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CMX - Black
Version null Generated 5/29/17 - http://www.nexans.com.br Page 35 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Dimensional characteristics
Approximate weight 26.5 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 100 m
Packaging Box
Installation type Indoor
Category Cat. 5e
Electro magnetic interference resistance No
Fire retardant IEC 60332-1
Ambient dynamic operating temperature, range -20 .. 60 °C
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CMX - Black
Version null Generated 5/29/17 - http://www.nexans.com.br Page 36 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CMX - Blue
Version null Generated 5/29/17 - http://www.nexans.com.br Page 37 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.561300
The Nexans ESSENTIAL 6 UTP cables were designed for horizontal applications in structured wiring networks to connectthe user’s socket with the administration panel or for the administrative panels interconnection. Your application is limited onthe bandwidth of 100MHz, class D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analogical and digital communication for video and voice•Power Over Ethernet (PoE)•
Category 5E – U/UTP•Annealed bare copper conductor isolated by a high density polyethylenethermoplastic. The conductors (veins) are twisted and reunited, forming the 4pairs core. A flame retardant layer material is applied over the core.
•
Produced according to the RoHS standard,• PVC CMX• Nominal diameter 24AWG (approximately 0,51mm)•
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CMX - Blue
Version null Generated 5/29/17 - http://www.nexans.com.br Page 38 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Dimensional characteristics
Approximate weight 26.5 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 100 m
Packaging Box
Installation type Indoor
Category Cat. 5e
Electro magnetic interference resistance No
Fire retardant IEC 60332-1
Ambient dynamic operating temperature, range -20 .. 60 °C
Essential-5 cable.ESSENTIAL CAT5E U/UTP 4P 24AWG - CMX - Blue
Version null Generated 5/29/17 - http://www.nexans.com.br Page 39 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Version null Generated 5/29/17 - http://www.nexans.com.br Page 40 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: N100.564x30
The Nexans ESSENTIAL 6 UTP cables were designed for horizontal applications in structured wiring networks to connectthe user’s socket with the administration panel or for the administrative panels interconnection. Your application is limited onthe bandwidth of 100MHz, class D.
Standards
International ISO/IEC 11801
Description
Fast Ethernet 100BASE-TX•Gigabit Ethernet 1000BASE-T•Token ring•155 Mbps ATM•100 Mbps TP-PMD•ISDN•Analogical and digital communication for video and voice•Power Over Ethernet (PoE)•
Category 5E – U/UTP•Annealed bare copper conductor isolated by a high density polyethylenethermoplastic. The conductors (veins) are twisted and reunited, forming the 4pairs core. A flame retardant layer material is applied over the core.
•
Produced according to the RoHS standard,•LSZH (Low Smoke Zero Halogen)•Nominal diameter 24AWG (approximately 0,51mm)•
Version null Generated 5/29/17 - http://www.nexans.com.br Page 41 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Dimensional characteristics
Outer Diameter 5 mm
Approximate weight 27 kg/km
Electrical characteristics
Resistance unbalance DC max % of loop resistance 5 %
Mutual capacitance at 1kHz 56 nF/100m
Nominal velocity propagation 69 %
Max. DC resistance of the conductor at 20°C 93.8 Ohm/km
Characteristic impedance 100 Ohm
Capacitance unbalance pair to ground at 1kHz 330 pF/100m
Transmission characteristics
Skew 45 ns/100m
Propagation delay, max. 100 MHz 545 ns/100m
Mechanical characteristics
Maximum installation tension 110 N
Usage characteristics
Length 305 m
Packaging Box
Installation type Indoor
Category Cat. 5e
Electro magnetic interference resistance No
Fire retardant IEC 60332-3
Ambient dynamic operating temperature, range -20 .. 60 °C
Version null Generated 5/29/17 - http://www.nexans.com.br Page 42 / 42
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation ofNexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.