Top Banner
eSHINE Install Manual 1. Base Section 2. Battery & Control Access hatch 3. Pole Dress Ring 4. Top section 5. Light arm 6. LED lamp 7. Glassless solar panels 8. Battery location 9. Control board fits in base section ( 1 ) 10 Solar tilt bracket assembl y 11. Batteries fit in base section ( 1 ) 7 B1 B2 B3 B4 BatteryS olar Lamp B1 B2 B3 B4 S1 L1 L2 L3 BatteryS olar Lamp B1 B2 B3 B4 S1 L1 L2 L3 FIELD WIRE TERMINATION Solar ( Yellow +, Black - ) Batteries ( red +, Black - ) LED ( Orange +, Black - ) 1 2 3 4 8 9 11 12 NOTE- Install pole dress ring before light arm or solar tilt bracket assembly 12 SOLAR C ONT R OLLER CIRCUIT BREAKERS LED DRIVERS + - + - + - + - + - + - + - + - To Load eSHINE POWER STATION S1, S2, S3 & S4 1. Layout base (1) and Top (4 ) sections 2. Use M16 socket bolts & washers 3. Slide on square dress ring 3) 4. Run solar cable and load cable 5. Bolt Light arm (5) using M12 socket bolts 6. Slide on Square light arm dress ring (10) 7. Connect solar tilt assembly to solar tray 8. Connect Solar Tilt Bracket assembly (11) 9. rotate to face True north ( South Hemi ) 10. Mount Load and terminate wiring 11. Crane into position 12. Solar panels can be installed on the ground or after the pole is craned into position * ©2014-2015 Valen energy , LLC. All rights reserved. Factory 9 8-10 Pioneer Dr. Woonona , NSW 2517 +1 512-222-5550 [email protected] www.valenenergy.com 2101 east st elmo rd Suite 310 Austin , TX 78744 +61 2 8005-6858 V alen energ Y
13

eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

Feb 01, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE Install Manual

1. Base Section2. Battery & Control Access hatch3. Pole Dress Ring4. Top section5. Light arm6. LED lamp7. Glassless solar panels8. Battery location9. Control board �ts in base section ( 1 )10 Solar tilt bracket assembl y11. Batteries �t in base section ( 1 )

7

B1

B2

B3

B4

BatteryS olar Lamp

B1 B2 B3 B4 S1 L1 L2 L3 BatteryS olar Lamp

B1 B2 B3 B4 S1 L1 L2 L3

FIELD WIRE TERMINATION

Solar ( Yellow +, Black - )Batteries ( red +, Black - )

LED ( Orange +, Black - )

12

3

4

8

9

11

12

NOTE- Install pole dress ring before light arm orsolar tilt bracket assembly

12

SOLAR CONTROLLER

CIRCUIT BREAKERS

LED DRIVERS

+ - + - + - + - + - + - + - + -

To Load

eSHINE POWER STATION S1, S2, S3 & S4

1. Layout base (1) and Top (4 ) sections2. Use M16 socket bolts & washers 3. Slide on square dress ring 3)4. Run solar cable and load cable5. Bolt Light arm (5) using M12 socket bolts 6. Slide on Square light arm dress ring (10)7. Connect solar tilt assembly to solar tray8. Connect Solar Tilt Bracket assembly (11) 9. rotate to face True north ( South Hemi )10. Mount Load and terminate wiring11. Crane into position12. Solar panels can be installed on the ground or after the pole is craned into position *

©2014-2015 Valen energy , L L C. All rights reserved.

Factory 98-10 Pioneer Dr.Woonona, NSW 2517

+1 512-222-5550

[email protected]

2101 east st elmo rd Suite 310

Austin, TX 78744 +61 2 8005-6858

Valen energY

Page 2: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE Install Manual

- Negative

+ PositiveThrough Pole To Control Board

Solar panel wiring assembly ( 2 panels )

Solar Tilt Bracket assembly

Slide the solar tray over the Panel/s and centre it to the solar panel/sThe tray has holes which intercept the solar panel frame use the self drilling screws to secure solar panel to solar tray ( 4 self drilling screws )Slide solar tilt bracket onto the solar tray and secure with 4 boltsFeed wire into the tilt bracket and out into the solar panel and connect+ and - wire. Place backing sheets onto the solar panel and screw down

©2014-2015 Valen energy , L L C. All rights reserved.

8-10 pioneer driveWoonona, NSW 2517

+1 512-222-5550

[email protected]

2101 east st elmo rd Suite 310

Austin, TX 78744 +61 2 8378 5917

Valen energY Factory 9,

Page 3: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE Shadowing

Midday Sun

Trees blocking sunlight all morning

East

6 Hr RUN TIME ORREDUCE LUMEN VALUE

Midday Sun

Trees blocking sunlight until mid morning

East

9 Hr RUN TIMEORREDUCE LUMEN VALUE

When selecting solar power it is important to position the system to optimise sunlight exposure. Trees and buildings are a common issue for solar systems but there is always a solution. You can reduce run time orreduce wattage ( Lumen value ) of the system.

Below are some examples of shadowing and how to adjust the system to function in these situations.When reducing run time the system can always run all night ( but you need to dim during the mid part of the night) you simply split the time so you receive full power during peak periods, reduce the lumen value

Valen Energy reserves the right to make changes at any time in order to supply the best product possible.

2101 East Saint Elmo Drive Suite 310

Austin TX 78744Tel: +1 512-222-5550

American Office Australian OfficeFactory 98-10 Pioneer DriveWoonona NSW 2517Tel: +61 2 8378 5917

www.valenenergy.com [email protected]

Page 4: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE Shadowing

SUMMER SUN

WINTER SUN

Santa Barbara latitude is 35oNSUMMER- June 21 solar noon zenith angle = 35 - 23.5 = 11.5o (sun angle = 78.5o)WINTER- Dec. 21 solar noon zenith angle = 35 - (-23.5) = 58.5o (sun angle = 31.5o)

Winter sun angle calculation

31.5 degrees

78.5 degreesSUMMER

WINTER

Valen Energy reserves the right to make changes at any time in order to supply the best product possible.

2101 East Saint Elmo Drive Suite 310

Austin TX 78744Tel: +1 512-222-5550

American Office Australian OfficeFactory 98-10 Pioneer DriveWoonona NSW 2517Tel: +61 2 8378 5917

www.valenenergy.com [email protected]

Page 5: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE Shadowing

Midday Sun

Trees blocking sunlight mid afternoon

East

9 Hr RUN TIMEORREDUCE LUMEN VALUE

Trees blocking sunlight to 3 bollards

East

Solution- Utilise a Vertaic or eSHINE power system to elevate above trees and run low voltage cable to bollards

Low voltage cable is run in shallow underground conduit to power the lighting systems surrounded by trees

Remote power stations- Trees blocking solar powered vertaic bollards

vERTAIC and eSHINE power systems

Valen Energy reserves the right to make changes at any time in order to supply the best product possible.

2101 East Saint Elmo Drive Suite 310

Austin TX 78744Tel: +1 512-222-5550

American Office Australian OfficeFactory 98-10 Pioneer DriveWoonona NSW 2517Tel: +61 2 8378 5917

www.valenenergy.com [email protected]

Page 6: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE - ePole-S1 Diagrams

A - A B - B C - C

AA

CCC

B

B

200x200mm (7.87” x 7.87”)

TW x TW

150mm ( 5.91”)

ø60m

m (2

.36”

)

1900

mm

( 74

.80”

)

1300

mm

(51.

18”)

500m

m (1

9.69

”)

200mm (7.87”)

200m

m (7

.87”

)

D

Section D

TW Square Section

Solar tilt Section

Anchor Bolts

800m

m (

31.5

”)

80m

m (

3.15

”)

80mm (3.15”)

M30

TS

LH

45°

Solar Bracket

PH

2450mm (8’) 3960mm (13’) 5490mm (18’) 7000mm (23’)

3050mm (10’) 4500mm (15’) 6000mm (20’)

120mm (4.7”) 120mm (4.7”) 120mm (4.7”) 120mm (4.7”)

360mm (14.1”) 1048mm (3.5’) 2570mm(8.4’) 4095mm(13.4’)

N/A

NOTE:1. All measurements are in mm with imperial measurements shown in ( )2. Inches have the following symbol “ 3. Feet have the following symbol ‘

2000mm ( 6’ ) 3000mm ( 10’ ) 4500mm ( 15’ ) 6000mm ( 20’ )POLE HEIGHT

PH

LH

TWTS

SET ( GRUB ) Screws

Solar Tilt Section

Battery and controlAccess panel

Base plate ( see base template for anchor dimensions )

Connection Between base and top sections

4 per pole

1000mm(39”) OR 2000mm(78”)

Valen Energy reserves the right to make changes at any time in order to supply the best product possible.

2101 East Saint Elmo Drive Suite 310

Austin TX 78744Tel: +1 512-222-5550

American Office Australian OfficeFactory 98-10 Pioneer DriveWoonona NSW 2517Tel: +61 2 8378 5917

www.valenenergy.com [email protected]

Page 7: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE - ePole-S2 Diagrams

AA

CCC

B

B

250mmx 250mm (9.84 x 9.84”)

TW x TW

1920

mm

(78.

75”)

1300

mm

( 51

.11”

)

D

TS

LH

45°

PH

2450mm (8’) 3960mm (13’) 5490mm (18’) 7000mm (23’)

3050mm (10’) 4500mm (15’) 6000mm (20’)

120mm (4.7”) 120mm (4.7”) 120mm (4.7”) 120mm (4.7”)

360mm (14.1”) 1048mm (3.5’) 2570mm(8.4’) 4095mm(13.4’)

N/A

NOTE:1. All measurements are in mm with imperial measurements shown in ( )2. Inches have the following symbol “ 3. Feet have the following symbol ‘

2000mm ( 6’ ) 3000mm ( 10’ ) 4500mm ( 15’ ) 6000mm ( 20’ )POLE HEIGHT

PH

LH

TWTS

8500mm (28’) 10,000mm (33’)

7500mm (25’) 9100mm (30’)

150mm (5.9”) 150mm (5.9”)

5620mm(18.4’) 7910mm(26’)

7500mm ( 25’ ) 9000mm ( 30’ )

150mm ( 5.91”)

ø60m

m (2

.36”

)

Section D

TW Square Section

Solar tilt Section

Anchor Bolts

800m

m (

31.5

”)

80m

m (

3.15

”)80mm (3.15”)

M30

SET ( GRUB ) Screws

4 per pole

A - A B - B C - C

500m

m (1

9.69

”)

250mm (9.84”)

250m

m (9

.84”

)

Battery and controlAccess panel

Base plate ( see base template for anchor dimensions )

Connection Between base and top sections

Solar Bracket

1000mm(39”) OR 2000mm(78”)

Valen Energy reserves the right to make changes at any time in order to supply the best product possible.

2101 East Saint Elmo Drive Suite 310

Austin TX 78744Tel: +1 512-222-5550

American Office Australian OfficeFactory 98-10 Pioneer DriveWoonona NSW 2517Tel: +61 2 8378 5917

www.valenenergy.com [email protected]

Page 8: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE - ePole-S3Diagrams

AA

CCC

B

B

TW x TW

1920

mm

(78.

75”)

D

TS

LH

45°

600mm (23.60”)

B

B

600mm (23.60”)

PH

2450mm (8’) 3960mm (13’) 5490mm (18’) 7000mm (23’)

3050mm (10’) 4500mm (15’) 6000mm (20’)

120mm (4.7”) 120mm (4.7”) 120mm (4.7”) 120mm (4.7”)

360mm (14.1”) 1048mm (3.5’) 2570mm(8.4’) 4095mm(13.4’)

N/A

NOTE:1. All measurements are in mm with imperial measurements shown in ( )2. Inches have the following symbol “ 3. Feet have the following symbol ‘

2000mm ( 6’ ) 3000mm ( 10’ ) 4500mm ( 15’ ) 6000mm ( 20’ )POLE HEIGHT

PH

LH

TWTS

8500mm (28’) 10,000mm (33’)

7500mm (25’) 9100mm (30’)

150mm (5.9”) 150mm (5.9”)

5620mm(18.4’) 7910mm(26’)

7500mm ( 25’ ) 9000mm ( 30’ )

Solar Bracket

150mm ( 5.91”)

ø60m

m (2

.36”

)

Section D

TW Square Section

Solar tilt Section

Anchor Bolts

800m

m (

31.5

”)

80m

m (

3.15

”)

80mm (3.15”)

M30

SET ( GRUB ) Screws

4 per pole

A - A B - B C - C

600m

m (2

3.60

”)

250mm (9.84”)

250m

m (9

.84”

)

Battery and controlAccess panel

Base plate ( see base template for anchor dimensions )

Connection Between base and top sections

250mmx 250mm (9.84 x 9.84”)

1000mm(39”) OR 2000mm(78”)

Valen Energy reserves the right to make changes at any time in order to supply the best product possible.

2101 East Saint Elmo Drive Suite 310

Austin TX 78744Tel: +1 512-222-5550

American Office Australian OfficeFactory 98-10 Pioneer DriveWoonona NSW 2517Tel: +61 2 8378 5917

www.valenenergy.com [email protected]

Page 9: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE - ePole-S4 Diagrams

AA

CCC

B

B

300mmx300mm (11.81 x 11.81”)

TW x TW

D

TS

LH

45°

B

B

PH

2450mm (8’) 3960mm (13’) 5490mm (18’) 7000mm (23’)

3050mm (10’) 4500mm (15’) 6000mm (20’)

360mm (14.1”) 1048mm (3.5’) 2570mm(8.4’) 4095mm(13.4’)

N/A

NOTE:1. All measurements are in mm with imperial measurements shown in ( )2. Inches have the following symbol “ 3. Feet have the following symbol ‘

2000mm ( 6’ ) 3000mm ( 10’ ) 4500mm ( 15’ ) 6000mm ( 20’ )POLE HEIGHT

PH

LH

TWTS

8500mm (28’) 10,000mm (33’)

7500mm (25’) 9100mm (30’)

150mm (5.9”) 150mm (5.9”)

5620mm(18.4’) 7910mm(26’)

7500mm ( 25’ ) 9000mm ( 30’ )

Section D

TW Square Section

Solar tilt Section

Anchor Bolts80

0mm

( 31

.5”)

80m

m (

3.15

”)

80mm (3.15”)

M30

SET ( GRUB ) Screws

4 per pole

A - A B - B C - C

600m

m (2

3.60

”)

300mm (11.8”)

300m

m (

11.8

”)

Battery and controlAccess panel

Base plate ( see base template for anchor dimensions )

Connection Between base and top sections

600mm (23.60”)

600mm (23.60”)1920

mm

(78.

75”)

150mm (5.9”) 150mm (5.9”) 150mm (5.9”) 150mm (5.9”)

Solar Bracket

150mm ( 5.91”)

ø60m

m (2

.36”

)

1000mm(39”) OR 2000mm(78”)

4. Base section dimensions 1920mm ( 78.75”) may vary depending on battery sizes ( LH will remain the same but TS will change accordingly)

Valen Energy reserves the right to make changes at any time in order to supply the best product possible.

2101 East Saint Elmo Drive Suite 310

Austin TX 78744Tel: +1 512-222-5550

American Office Australian OfficeFactory 98-10 Pioneer DriveWoonona NSW 2517Tel: +61 2 8378 5917

www.valenenergy.com [email protected]

Page 10: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE - ePole-S1 Base Plate Templates

400mm / 15.75”

400m

m /

15.7

5”

31mm / 1.22ӯ

58mm / 2.31”

58m

m /

23.

1”

Valen Energy reserves the right to make changes at any time in order to supply the best product possible.

2101 East Saint Elmo Drive Suite 310

Austin TX 78744Tel: +1 512-222-5550

American Office Australian OfficeFactory 98-10 Pioneer DriveWoonona NSW 2517Tel: +61 2 8378 5917

www.valenenergy.com [email protected]

Page 11: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE - ePole-S2 Base Plate Templates

450mm / 17.71”

450m

m/

1 7

7.1”

31mm / 1.22ӯ

65mm / 2.59”

65m

m/

2 5.

9 ”

Valen Energy reserves the right to make changes at any time in order to supply the best product possible.

2101 East Saint Elmo Drive Suite 310

Austin TX 78744Tel: +1 512-222-5550

American Office Australian OfficeFactory 98-10 Pioneer DriveWoonona NSW 2517Tel: +61 2 8378 5917

www.valenenergy.com [email protected]

Page 12: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE - ePole-S3 Base Plate Templates

450mm / 17.71”

450m

m/

1 7

7.1”

31mm / 1.22ӯ

65mm / 2.59”

65m

m/

2 5.

9 ”

Valen Energy reserves the right to make changes at any time in order to supply the best product possible.

2101 East Saint Elmo Drive Suite 310

Austin TX 78744Tel: +1 512-222-5550

American Office Australian OfficeFactory 98-10 Pioneer DriveWoonona NSW 2517Tel: +61 2 8378 5917

www.valenenergy.com [email protected]

Page 13: eSHINE Install Manual eSHINE Install Manual - Negative + Positive Through Pole To Control Board Solar panel wiring assembly ( 2 panels ) Solar Tilt Bracket assembly Slide the solar

eSHINE - ePole-S4 Base Plate Templates

31mm / 1.22ӯ

500mm / 19.69”

500m

m /

19.6

9”

Valen Energy reserves the right to make changes at any time in order to supply the best product possible.

2101 East Saint Elmo Drive Suite 310

Austin TX 78744Tel: +1 512-222-5550

American Office Australian OfficeFactory 98-10 Pioneer DriveWoonona NSW 2517Tel: +61 2 8378 5917