Results of a multicentric in silico clinical trial (ROCOCO): comparing radiotherapy with photons and protons for non-small cell lung cancer. Erik Roelofs MSc Medical Physicist MAASTRO clinic Maastricht, Juli 2011. Flowchart to determine eligibility of a patient to receive proton therapy. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Erik  Roelofs  MSc Medical Physicist MAASTRO  clinic Maastricht,  Juli  2011

Cancer.orgPredict

Results of a multicentric in silico clinical trial (ROCOCO): comparing radiotherapy with photons and protons for non-small cell lung cancer

Erik Roelofs MScMedical PhysicistMAASTRO CLINICMaastricht, Juli 2011

Page 2: Erik  Roelofs  MSc Medical Physicist MAASTRO  clinic Maastricht,  Juli  2011

Flowchart to determine eligibility of a patient to receive proton therapy.

*Using peer-reviewed, published and externally validated models.

Roelofs et al., J. Thorac Oncol, 2011

Page 3: Erik  Roelofs  MSc Medical Physicist MAASTRO  clinic Maastricht,  Juli  2011

Comparison of dose distributions of 3DCRT, IMRT and PSPT treatment plans (columns) for three cases (rows). The target is shown (thick red line) with isodose lines of 1, 10, 25, 50 and 67 Gy (thin red line).

#2#1

53DCRT IMRT PSPT

#6

Roelofs et al., J. Thorac Oncol, 2011

Page 4: Erik  Roelofs  MSc Medical Physicist MAASTRO  clinic Maastricht,  Juli  2011

DVHs for patient #2 where the prescribed dose of 70 Gy resulted in exceeding the critical MLD level. Shown are DVHs for 3DCRT (solid), IMRT (dashed) and PSPT (dotted) plans.*MLD refers to the DVH of both left and right lung volumes minus the GTV.

DVHs for patient #2 – Prescribed dose (70Gy)

Roelofs et al., J. Thorac Oncol, 2011

Page 5: Erik  Roelofs  MSc Medical Physicist MAASTRO  clinic Maastricht,  Juli  2011

DVHs for patient #2 where the dose was lowered to the maximum tolerable dose, showing larger under-dosage for 3DCRT (solid) than for IMRT (dashed) or PSPT (dotted).*MLD refers to the DVH of both left and right lung volumes minus the GTV.

Roelofs et al., J. Thorac Oncol, 2011

DVHs for patient #2 – Maximum Tolerable Dose