Top Banner
Equipment for the Chemistry Lab Ms. Towle
17

Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements These pieces of equipment provide accurate measurements when read properly.

Dec 27, 2015

Download

Documents

Estella Warner
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

Equipment for the Chemistry Lab

Ms. Towle

Page 2: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

Accurate Measurements These pieces of equipment provide

accurate measurements when read properly.

Page 3: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

How to read a graduated cylinder

Your eye line should be even with the BOTTOM of the meniscus (curved surface of a liquid).

Page 4: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

How to use a triple beam balance Always carry the balance with two hands Set all the riders to zero and remove any

material from the balance pan. Calibrate the balance by turning the

adjustment screw until the pointer on the end of the beam aligns with the center mark.

Only solids should be placed directly on the pan. Loose solids should be placed in a weigh boat or weigh paper and liquids should be placed in a container.

Page 5: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

How to use a triple beam balance Move the largest rider along the beam

one notch at a time until the pointer drops. Ten move the rider back on notch. Repeat this procedure with the next smallest rider. Continue in the same manner until you are using the smallest rider.

Page 6: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

How to use a triple beam balance The beam on which the smallest rider

moves does not have any notches. Slowly slide the rider along until the pointer on the end of the beam aligns with the center mark.

The mass of the object on the pan is the sum of the masses shown on the beams. E sure to subtract the mass of the container, if any.

Page 7: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

How to use a triple beam balance

Page 8: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

Approximate Measurements These pieces of equipment do not

provide accurate measurements but can be used for approximate measurements.

Page 9: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

Other Equipment

Page 10: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

Other Equipment

Page 11: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

Other Equipment

Page 12: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

Other equipment

Page 13: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

Safety Equipment These should be worn to protect

yourself from potential injuries.

Page 14: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

Equipment used for heating

Page 15: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

How to use a bunsen burner Check the rubber tubing for any cracks. Push the end of the rubber tubing onto

the gas valve. Make sure the burner is level and on a

flat surface and away from any flammable material.

Close the air intake valve.

Page 16: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

How to use the bunsen burner Light a match and hold it against the

lower side of the burner tube. Turn on the gas slowly and move the match up until the gas ignites.

Adjust the flame by manipulating the air intake control a good burner flame gives off little light and has two distinct cones.

Page 17: Equipment for the Chemistry Lab Ms. Towle. Accurate Measurements  These pieces of equipment provide accurate measurements when read properly.

How to adjust the flame on a bunsen burner

If the flame is: Too large, slowly turn down the gas. Yellow and/or smoky, adjust the air intake

control. Disappears down the tube, turn off the gas

with the valve, decrease the air intake, and relight the burner.

If there is a gap between the top of the tube and the base of the flame, slowly turn down the gas.