177 P 17 Tempra Pro industrial sockets & plugs (p. 219) EQUIPMENT & ACCESSORIES NEW PRODUCTS 2014 P. 179 Colring cable ties P. 199 Starfix ferrules & crimping tools P. 219 P 17 Tempra Pro IP 44 - 16/32 A industrial sockets & plugs P. 232 P 17 Tempra interlocked switched sockets Cabling components & marking systems Control and signalling devices Industrial sockets & other equipment NEW P. 209 Osmoz non-illuminated heads control & signalling units AVAILABLE SEPT 2014
56
Embed
EQUIPMENT & ACCESSORIES - reynoldsonline.com & ACCESSORIES NEW PRODUCTS 2014 ... Conform to EN 62275 type 1 (NFC 68-146) "cable ties for electrical installations" Recognized UL 1565
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
177
P 17 Tempra Proindustrial sockets & plugs(p. 219)
EQUIPMENT & ACCESSORIES
NEW PRODUCTS 2014
P. 179Colring cable ties
P. 199Starfix ferrules & crimping tools
P. 219P 17 Tempra Pro IP 44 - 16/32 A industrial sockets & plugs
P. 232P 17 Tempra interlocked switched sockets
Cabling components & marking systems
Control and signalling devices
Industrial sockets & other equipment
NEW
P. 209Osmoz non-illuminated heads control & signalling units
AVAILABLESEPT 2014
178
P. 191Accessories for Viking 3 terminal blocks
P. 189Viking 3 terminal blocks with spring connection
P. 197Viking 3 power terminal blocks
P. 204Memocab marking system
P. 206Transcab cable ducting
P. 207Lina 25 cable ducting
P. 222P 17 Tempra IP 66/67 - 63/125 A industrial sockets & plugs
P. 229P 17 Tempra combined units to be composed
P. 221P 17 Tempra Pro IP 66/67 - 16/32 A industrial sockets & plugs
P. 220P 17 Tempra ELV IP 44 - 16/32 A industrial sockets & plugs
P. 187Viking 3 terminal blocks with screw connection
P. 201CAB 3 marking system
P. 210Osmoz illuminated heads control & signalling units
179
ColringTM equipment cable ties
0 320 61/14/31/19/20/490 320 42 blister packing
For series assembly of electrical cables With self blocking head and internal teeth Conform to EN 62275 type 1 (NFC 68-146)
1: Non orientated head 2: Sachet packing 100 pcs 3: Non orientated head and sachet packing 100 pcs
DUPLIX MARKING SYSTEM Opened or closed marking system with markers or labels. Fitted using 2.4 and 3.5 mm Colring cable ties.
IDENTIFICATIONPLATESWhite identification plates 38.5 x 19 mmFitted using 4.6 mm Colring cable ties.
Viking 3 terminal blocks p. 183
ColringTM accessories for equipmentcable ties
Pack Cat.Nos Colring tool
1 0 320 88 P. 46 Colring tool for cable ties max. width 4.6 mmDirect adjustment of clamping tension by using the milled screw at the base of handleAfter clamping, a blade automatically cuts the surplus length close to the head without leaving a burrFor cable ties width 7.6 and 9 mm,use Colson tool Cat.No 0 319 96
Bases
Self-adhesivePossibility to screw fixing Ø4 mm
100/2000 0 320 65 Colourless - 25 x 30 x 6 mmFor cable ties max. width 4.6 mm
100/2000 0 320 67 Black - 25 x 30 x 6 mmFor cable ties max. width 4.6 mm
50 0 320 68 Black - 38 x 38 x 9.4 mmFor cable ties max. width 20 mm
Screw-mountingColourless
1000 0 320 70 For cable ties max. width 4.6 mm15 x 10 x 6 mm - Screw fixing Ø4 mm
100 0 320 72 For cable ties max. width 9 mm21 x 16.5 x 8.8 mm - Screw fixing Ø5 mm
Clip-on1000 0 320 76 For cable ties max. width 4.6 mm
For th. 0.5 to 3 mm, drilling Ø6 to 6.5 mmMounting on Lina 12.5 plates for cabinetsand enclosures and on Lina 25 platesfor cabinets (p. 163)
Marking accessories
100 0 320 85 White identification plate 38.5 x 19 mmfor cable ties max. width 4.6 mmUse felt tip pen Cat.No 0 395 98 for marking
10 0 395 98 Black felt tip penIndelible for marking
0 320 88
0 320 76
0 320 85 0 395 98
0 320 65
0 320 720 320 67 0 320 68
181
ColringTM equipment cable ties
Performance
Conform to EN 62275 type 1 (NFC 68-146) "cable ties for electrical installations" Recognized UL 1565 approval
Ratchet / tensile strength and temperature resistance
External agents resistance
- Good resistance to bases, oils, greases, petroleum products, chlorinated solvents - Humidity retention: 1.5 % humidity retention 3 %
Fire resistance
- Flame resistance UL 94: V2- Flame-retardant - Needle flame test according to IEC 60695-11-5 - Oxygen index: EN ISO 4589-1 / ASTM D 2863-00:28.5% (26% for Colring black) - Halogen-free polyamide, class 1 acc. to ASTM D 4066 (Class 2 for Colring black)
Dimensions
Identification cable ties
Accessories
25
8
12
28
Cat.No 0 320 63Cat.No 0 320 61
Cat.Nos 0 320 65/67 Cat.No 0 320 70
Cat.No 0 320 76Cat.No 0 320 72
Cat.No 0 320 85
6 30
2 25
5
Ø4.2
4 21
8.8 9.5
Ø 5.2
16.5
3.8
5
7.5
Ø 6.3
11.5 4
10
38.5
6 Ø 5.3
19
11
2.4
15
10
Ø 4.2
6 5
Duplix marker holders Cat.No 0 384 52,
attached using 2 Colring cable ties Cat.
No 0 320 31, equipped with labels
Example of use
Cat.Nos
Ratchet force (daN)
Tensile strength according to EN 50146 Temperature resistance
� test (mm)
Min tensile
strength (daN)
Max. operating
temperature (°C)
Min. operating
temperature (°C)
Min. installation temperature
(°C)
Co
lou
rle
ss C
olr
ing
ca
ble
tie
s
0 320 30 0.5 18 8 75 -40 -10
0 320 31 0.5 20 8 75 -40 -10
0 320 32 0.5 38 8 75 -40 -10
0 320 37 0.5 20 13 75 -40 -10
0 320 38 0.5 38 13 75 -40 -10
0 320 39 0.5 38 13 75 -40 -10
0 320 40 0.5 38 13 75 -40 -10
0 320 42 0.5 38 22 75 -40 -10
0 320 43 0.5 38 22 75 -40 -10
0 320 44 0.5 38 22 75 -40 -10
0 320 47 1 38 53 75 -40 -10
0 320 49 1 38 53 75 -40 -10
0 320 50 1 38 53 75 -15 -10
0 320 52 0.45 20 8 75 -40 -10
0 320 54 0.6 20 13 75 -40 -10
0 320 55 0.9 38 22 75 -40 -10
0 320 57 0.9 38 22 75 -40 -10
0 320 58 1.5 38 53 75 -40 -10
0 320 61 0.5 38 8 75 -40 -10
0 320 63 0.5 38 22 75 -40 -10
0 320 45 2 38 53 75 -15 -10
0 320 46 2 38 77 75 -15 -10
0 320 48 2 38 77 75 -15 -10
0 320 51 2 38 111 75 -15 -10
Bla
ck C
olr
ing
ca
ble
tie
s
0 320 12 0.5 18 8 105 -40 0
0 320 13 0.5 20 8 105 -40 0
0 320 14 0.5 38 8 105 -40 0
0 320 15 0.5 20 13 105 -40 0
0 320 18 0.5 38 13 105 -40 0
0 320 19 0.5 38 13 105 -40 0
0 320 20 0.5 38 13 105 -40 0
0 320 22 0.5 38 22 105 -40 0
0 320 23 0.5 38 22 105 -40 0
0 320 24 0.5 38 22 105 -40 0
0 320 29 1 38 53 105 -40 0
0 320 25 2 38 53 85 -15 0
0 320 26 2 38 77 85 -15 0
0 320 27 2 38 77 85 -15 0
0 320 28 2 38 111 85 -15 0
Cat.Nos
Ratchet force (daN)
Tensile strength according to EN 50146 Temperature resistance
Mintensile
strength (daN)
Max. operating
temperature (°C)
Min. operating
temperature (°C)
Min. installation temperature
(°C)
Co
lou
rle
ss C
olr
ing
ca
ble
tie
s
0 318 20 1 8 85 -15 -10
0 318 21 1 8 85 -15 -10
0 318 22 1 8 85 -15 -10
0 318 23 1 13 85 -15 -10
0 318 24 1 13 85 -15 -10
0 318 25 1 13 85 -15 -10
0 318 26 1 13 85 -15 -10
0 318 27 1.5 22 85 -15 -10
0 318 28 1.5 22 85 -15 -10
0 318 29 1.5 22 85 -15 -10
0 318 33 1.5 22 85 -15 -10
0 318 30 2 53 85 -15 -10
0 318 34 2 53 85 -15 -10
0 318 31 2 53 85 -15 -10
0 318 35 2 53 85 -15 -10
0 318 32 2 53 85 -15 -10
0 318 36 2 77 85 -15 -10
0 318 37 2 77 85 -15 -10
0 318 38 2 111 85 -15 -10
Bla
ck C
olr
ing
ca
ble
tie
s
0 318 00 1 8 105 -15 0
0 318 01 1 8 105 -15 0
0 318 02 1 8 105 -15 0
0 318 03 1 13 105 -15 0
0 318 04 1 13 105 -15 0
0 318 05 1 13 105 -15 0
0 318 06 1 13 105 -15 0
0 318 07 1.5 22 105 -15 0
0 318 08 1.5 22 105 -15 0
0 318 09 1.5 22 105 -15 0
0 318 13 1.5 22 105 -15 0
0 318 10 2 53 105 -15 0
0 318 14 2 53 105 -15 0
0 318 11 2 53 105 -15 0
0 318 15 2 53 105 -15 0
0 318 12 2 53 105 -15 0
0 318 16 2 77 105 -15 0
0 318 17 2 77 105 -15 0
0 318 18 2 111 105 -15 0
182
TERMINAL BLOCKS
VIKING™ 3
SCREW CONNECTION
High contact pressure Excellent mechanical strength Permissible cross-sections: 0.25 mm² to 70 mm² (flexible wire) and 0.25 mm² to 95 mm² (rigid wire)
Identical height for blocks of 16 mm² to 70 mm²
AUTOMATIC SPRING CONNECTION
No tool required for connection Constant contact pressure Permissible cross-sections: 0.5 mm² to 16 mm² with or without ferrule
Integrated end caps for pitches of 6 to 12
Pitch of 5
Pitch of 6
International approvals: UL/CSA/NF/IMQ/BV ATEX certification
Conform to IEC EN 60947-7-1, IEC EN 60947-7-2 and IEC EN 60947-7-3
Addition of functions
on module for equipping:
standard, neutral or protected isolation, mini-circuit-breaker, automotive-type fuse, etc.
Screw or automatic spring connection
Single end caps for pitches of 5 to 10.
Optimized terminal block size. Identical electrical characteristics for blocks with a pitch of 5 and those with a pitch of 6.
183
ELECTRICALFUNCTION
Connecting(p. 187)
1 connection - 1 entry/1 outlet
1 connection - 2 entries/2 outlets
2 connections on 2 levels
3 connections on 3 levels
For protectionconductor(p. 187)
1 connection - 1 entry/1 outlet - metal base
1 connection - 2 entries/2 outlets - metal base
Disconnect(p. 188)
1 connection
Open (to be equipped)
For fuse cartridge 5 x 20 with handle lever
For fuse cartridge 5 x 20 with handle lever+ blown fuse indicator
For neutral circuit with handle lever
For standard circuitWith handle lever
With mini lever
For circuit notbroken
With handle lever
With mini lever
For fuse cartridge 5 x 20 with screwed plug
Functionblocks (p. 188)
1 connectionModular
Diode carrier 1N4007
2 connectionson 2 levels
Diode carrier 1N4007
With voltage presence LED
For sensorand actuator(p. 188)
3 connectionson 3 levels
Sensor
Actuator
PNE (p. 187) Phase/Neutral/Earth
Measurement (p. 188)
1 connection Disconnect for measuring circuit
1: Blown fuse indicator 12/24/48 V = /A Cat.No 0 375 24 or 110/250 VA Cat.No 0 375 25 - 2: Or end stop Cat.No 0 375 10 - 3: Upper level only - 4: Lower level only - 5: Lower and intermediate levels
N
0 371 00 0 371 20
0 371 61 0 371 63 0 371 64
0 371 66 0 371 69 0 371 68
0 371 08
0 371 30
0 371 71 0 371 76
0 371 78
0 371 80
0 371 86
0 371 53
0 371 51 0 371 52 0 371 92
0 371 56
0 371 87
0 371 810 371 84
0 371 79
0 371 98
VikingTM 3 terminal blocks with screw connection and accessoriesfor copper cables
184
TERMINAL BLOCKS INSULATION EQUIPOTENTIAL LINK PROTECTIONMEASURE-
MENTASSOCIATED PRODUCTS
Nominalcross-section
(mm2)
Pitch(mm) C
olo
ur
Cat.Nos End capSeparation
and insulationdivider
Automatic insertion birdging comb Comb for 12 blocks,
VikingTM 3 terminal blocks with screw connectionfor copper cables
Pack Cat.Nos For protection conductor
Metal base
1 connection - 1 entry/1 outlet
Screwless fixing on rail up to 10 mm pitch and with screws for pitch 12 and 15 mmPEN from 10 mm2
Colour
Nominal cross-section (mm2)
Capacity
Pitch (mm)
Rigid wire (mm2)
Flexiblewire (mm2)
with or without ferrules
60 0 371 70 Green/yellow 2.5 0.25 to 4 0.25 to 2.5 550 0 371 71 Green/yellow 4 0.25 to 6 0.25 to 4 640 0 371 72 Green/yellow 6 0.5 to 10 0.25 to 6 830 0 371 73 Green/yellow 10 1.5 to 16 2.5 to 10 1010 0 371 74 Green/yellow 16 1.5 to 25 4 to 16 1210 0 371 75 Green/yellow 35 2.5 to 50 4 to 35 15
1 connection - bare block
10 0 371 76 - 35 2.5 to 50 4 to 35 15
1 connection - 2 entries/2 outlets
Screwless fixing on rail
50 0 371 79 Green/yellow 4 0.25 to 6 0.25 to 4 6
PNE - Phase/Neutral/Earth
3 connections on 3 levels
Metal baseGreen/yellow marking for the lower level Screwless fixing on rail
Colour
Nominal cross- section (mm²)
Capacity
Pitch (mm)
Rigid wire (mm2)
Flexiblewire (mm2)
with or without ferrules
50 0 371 522 Grey 2.5 0.25 to 4 0.25 to 2.5 5
Pack Cat.Nos Connecting
Grey for standard circuit, blue for neutralconductor, orange for circuit not broken by the master isolating device, red for special circuits(safety, protected, etc), green for protection conductor class II equivalent assemblies
1 connection - 1 entry/1 outlet
Colour
Nominal cross-section
(mm2)
Capacity
Pitch (mm)
Rigid wire (mm2)
Flexiblewire (mm2)
with or without ferrules
60 0 371 60 Grey
2.5 0.25 to 4 0.25 to 2.5 560 0 371 00 Blue60 0 371 20 Orange60 0 371 30 Red
50 0 371 61 Grey
4 0.25 to 6 0.25 to 4 650 0 371 01 Blue50 0 371 21 Orange50 0 371 31 Red50 0 371 77 Green
40 0 371 62 Grey6 0.5 to 10 0.25 to 6 840 0 371 02 Blue
3 connections on 3 levels50 0 371 512 Grey 2.5 0.25 to 4 0.25 to 2.5 5
1: Built-in end cap2: Rigid wire capacity: 2.5 mm2 max. with equipotential bridging comb
0 371 69 0 371 68
0 371 74 0 371 760 371 70 on rail 4
Used to make the electrical connection between 2 flexible copper wires with ou without ferrules or 2 rigid copper wires2 areas for automatic insertion bridging combs up to 8 pitch (upper level only for multi-level blocks)For rails 2 depth 15 mm, 2 EN 60715 depth 7.5 mm and 15 mm
Same profile up to 10 mm pitch and same height from 12 to 22 mm pitch
Technical characteristics p. 194 dimensions see e-catalogue
Viking 3 power terminal blocks
p. 197
CAB 3 marking system
p. 201
188
VikingTM 3 terminal blocks with screw connectionfor copper cables (continued)
1: Rigid wire capacity: 2.5 mm² max with equipotential brigding comb
0 371 80 + automotive-type fuse
0 371 55
0 371 82 + 0 371 83 + 0 371 85
0 371 51 0 371 52
0 371 84 + 0 371 86 0 371 53
0 371 92
0 371 87
Used to make the electrical connection between 2 flexible copper wires with ou without ferrules or 2 rigid copper wires2 areas for automatic insertion bridging combs up to 8 pitch (upper level only for multi-level blocks)For rails 2 depth 15 mm, 2 EN 60715 depth 7.5 mm and 15 mm
Opening by means of blade type lever, handle lever or mini lever (with tool)
Open (to be equipped)
Can take blade type levers Cat.Nos 0 375 15/16/17/18 or in ELV installations a blade-type automotive fuse or a miniature circuit-breaker
Colour
Nominal cross-section (mm²)
Capacity
Pitch (mm)
Rigid wire (mm2)
Flexiblewire (mm2)
with or without ferrules
20 0 371 80 Grey 2.5 0.25 to 2.5 0.25 to 2.5 6
For fuse cartridge 5 x 20 with handle lever20 0 371 81 Grey 2.5 0.25 to 2.5 0.25 to 2.5 6
For neutral circuit with blue handle lever20 0 371 82 Grey/blue 2.5 0.25 to 2.5 0.25 to 2.5 6
For standard circuit with handle lever20 0 371 83 Grey 2.5 0.25 to 2.5 0.25 to 2.5 6
For standard circuit with mini lever20 0 371 84 Grey 2.5 0.25 to 2.5 0.25 to 2.5 6
For circuit not broken with handle lever
Circuit not broken by the master isolating device
20 0 371 85 Orange 2.5 0.25 to 2.5 0.25 to 2.5 6
For circuit not broken with mini lever
Circuit not broken by the master isolating device
20 0 371 86 Orange 2.5 0.25 to 2.5 0.25 to 2.5 6
For cartridge 5 x 20 with screwed plug20 0 371 87 Grey 10 0.25 to 10 0.25 to 10 12
Function blocks
1 connection - modular
Component connected with screws
Colour
Nominal cross-section
(mm²)
Capacity
Pitch (mm)
Rigid wire (mm2)
Flexiblewire (mm2)
with or without ferrules
20 0 371 53 Grey 2.5 0.25 to 4 0.25 to 2.5 5
1 connection - diode carrier
20 0 371 54 Grey 2.5 0.25 to 4 0.25 to 2.5 5
2 connections on 2 levels - diode carrier60 0 371 55 Grey 4 0.25 to 6 0.25 to 4 6
2 connections on 2 levels - with LED
Voltage presence indicator (12/24V= and A)60 0 371 56 Grey 4 0.25 to 6 0.25 to 4 6
Pack Cat.Nos For sensors and actuators
For connecting sensors (Cat.No 0 371 51) or actuators (Cat.No 0 371 52), and their shared power supply unit using equipotential bridging comb Cat.Nos 0 375 46/47
3 connections on 3 levels - for sensor
Colour
Nominal cross-section
(mm²)
Capacity
Pitch (mm)
Rigid wire (mm2)
Flexiblewire (mm2)
with or without ferrules
50 0 371 511 Grey 2.5 0.25 to 4 0.25 to 2.5 5
3 connections on 3 levels - for actuator
Green/yellow marking for the lower levelMetal base. Screwless fixing on rail
50 0 371 521 Grey 2.5 0.25 to 4 0.25 to 2.5 5
Disconnect for measurement
1 connection
With its accessories, allows intervention(measurements, maintenance, etc) on a current,voltage and power measuring circuit by keeping thecurrent transformer secondary circuit closed
Colour
Nominal cross-section
(mm²)
Capacity
Pitch (mm)
Rigid wire (mm2)
Flexiblewire (mm2)
with or without ferrules
25 0 371 92 Grey 4 0.25 to 4 0.25 to 4 8
Technical characteristics p. 194 dimensions see e-catalogue
Blade type levers, joining rods and blown fuse
indicators p. 192
Accessories p. 191
189
VikingTM 3 terminal blocks with spring connectionfor copper cables
1: Built-in end cap
Pack Cat.Nos Connecting
Grey for standard circuit, blue for neutral conductor,orange for circuit not broken by the master isolatingdevice
1 connection - 2 wires - 1 entry/1 outlet
Colour
Nominal cross-section(mm²)
Capacity
Pitch (mm)
Rigid wire (mm2)
Flexible wire
(mm2)
Flexiblewire withferrule (mm2)
60 0 372 60 Grey4 0.5 to 6 0.5 to 4 0.5 to 2.5 560 0 372 00 Blue
60 0 372 20 Orange
50 0 372 611 Grey4 0.5 to 6 0.5 to 4 0.5 to 4 650 0 372 011 Blue
50 0 372 211 Orange
50 0 372 621 Grey6 0.5 to 6 0.5 to 6 0.5 to 6 8
50 0 372 021 Blue
40 0 372 631 Grey10 0.75 to 10 0.75 to 10 0.75 to 10 10
Screwless connection system, stainless steel spring typeUsed to make the electrical connection between 2 rigid copper wires, or flexible copper wires with or without ferrules (p. 199)Direct tool-free insertion of a rigid wire or flexible wire with ferrule, up to 6 mm pitch2 areas for automatic insertion bridging combs (upper level only for 2-level blocks)For rails 2 depth 15 mm, 2 EN 60715 depth 7.5 mm and 15 mm
Starfix ferrules and crimping tools
p. 199
CAB 3 marking system
p. 201
Technical characteristics p. 195 dimensions see e-catalogue
190
Blade type levers, joining rods and blown
fuse indicators p. 192
Accessories
p. 191 to 193
Starfix ferrules and crimping tools
p. 199
VikingTM 3 terminal blocks with spring connectionfor copper cables (continued)
0 372 81 open 0 372 82 + 0 372 83 + 0 372 85
0 372 80 with automotive-type fuse
0 372 84 0 372 54
0 372 81 with blown fuse indicator (p. 192)
0 372 56
Screwless connection system, stainless steel spring typeUsed to make the electrical connection between 2 rigid copper wires, or flexible copper wires with or without ferrules (p. 199)Direct tool-free insertion of a rigid wire or flexible wire with ferrule, up to 6 mm pitch2 areas for automatic insertion bridging combs (upper level only for 2-level blocks)For rails 2 depth 15 mm, 2 EN 60715 depth 7.5 mm and 15 mm
2 connections - 4 wires - 2 levels - diode carrier60 0 372 55 Grey 4 0.5 to 6 0.5 to 4 0.5 to 2.5 5
2 connections - 4 wires - 2 levels - with LED
Voltage presence indicator (12/24V= et A)60 0 372 56 Grey 4 0.5 to 6 0.5 to 4 0.5 to 2.5 5
Technical characteristics p. 195 dimensions see e-catalogue
191
VikingTM 3 accessories for terminal blocks
Pack Cat.Nos Rails for cutting to length
Length 2 m
10 0 374 04 4 EN 60715 depth 7.5 mm10 0 374 07 3 depth 15 mm10 0 477 22 4 depth 7.5 mm with oblong holes10 0 477 23 3 depth 15 mm with oblong holes
45° mounting bracket
10 0 394 49 Set of 2 supports for 45° rail slope Supplied with 4 M6 screws,nuts and washers
Adaptor
20 0 364 66 For mounting on rail 1 equipmentfitting on rail 2Width 17 mmIncrease equipment height for 6 mm
End stops
Accept CAB 3 markers
Automatic 6 mm pitch50 0 375 10 Screwless mounting
For rails 4 depth 15 mm and 4 EN 60715 depth 7.5 mm and 15 mmAccepts label holder Cat.No 0 395 96Acts as end cap for screw terminal blocks1 entry/1 outlet 5, 6, 8 and 10 mm pitch
8 mm pitch20 0 375 11 For rails 4 depth 15 mm and 4 EN 60715
depth 7.5 mm and 15 mmAccepts label holder Cat.No 0 395 96
10 mm pitch10 0 375 12 For rails 4 depth 15 mm and 4 EN 60715 depth
7.5 mm (except for rail fixed on plate) and 15 mmFor supporting protection or schielding bar:- Brass bar Cat.Nos 0 373 00/01 (p. 209)- Copper bar 12 x 4 mm with clamps Cat.No 0 373 02- IP 2X terminal block with flat steel bar 12 x 2 mmCat.No 0 048 19 (p. 129)- Copper bar 12 x 4 mm Cat.No 0 373 49 or 0 373 89 - Shielding bar 10 x 3 mm Cat.No 0 375 34 (p. 193)
12 mm pitch20 0 375 13 For rails 1 EN 60715, 4 depth 15 mm and 4
EN 60715 depth 7.5 mm and 15 mmAfter cutting out the upper divider, can be labelledusing Duplix label holder Cat.No 0 384 98
Pack Cat.Nos Identification accessories
20 0 395 96 Transparent label holder with variable angleFixing on end stops Cat.Nos 0 375 10/11Supplied with label 32 x 9.5 mmCan take label Cat.No 0 395 97
20 0 395 97 Label for engraving 28 x 9.5 mmFor label holder Cat. No 0 395 96. Flexible ABSWhite background, black engraving
10 0 395 98 Black felt tip penfor permanent marking
End caps
Grey
For screw terminal blocks100 0 375 50 1 entry/1 outlet 5, 6, 8 and 10 mm pitch20 0 375 51 1 entry/1 outlet 12 and 15 mm pitch20 0 375 52 2 entries/2 outlets20 0 375 53 2 levels20 0 375 54 3 levels20 0 375 55 Disconnect type 6 mm pitch and function blocks
5 mm pitch20 0 375 56 Disconnect type fuse cartridge 5 x 20 with screwed
plug10 0 375 57 Disconnect for measurement
For spring terminal blocks with 5 mm pitch
Allows the block to become 6 mm pitch and takea flexible wire fitted with a 4 mm2 ferrule (p. 292)
For spring terminal blocks10 0 375 95 1 entry/1 outlet, 1 entry/2 outlets and
2 entries/2 outlets 5 and 6 mm pitch10 0 375 96 2 levels
Equipotential bridging accessories
Brigding combs for screw and spring terminal blocks
Front mounting (automatic insertion), screwlessIsolated and separableConsecutive or alternating connection
20 0 375 001For 10 blocks with 5 mm pitch - blue
20 0 375 011For 10 blocks with 5 mm pitch - red
50 0 375 021For 2 blocks with 5 mm pitch - red
20 0 375 032For 10 blocks with 6 mm pitch - blue
20 0 375 042For 10 blocks with 6 mm pitch - red
50 0 375 052For 2 blocks with 6 mm pitch - red
20 0 375 073For 3 blocks with 8 mm pitch - red
20 0 375 083For 2 blocks with 8 mm pitch - red
Bars for screw terminal blocks
Front mounting with screwsPre-assembled, not insulated bar Consecutive or alternating connection
10 0 375 40 For 12 blocks with 10 mm pitch10 0 375 424
For 12 blocks with 12 mm pitch10 0 375 44 For 12 blocks with 15 mm pitch
Bridging combs for 3-level screw terminal blocks
For lower and intermediate levels of blocksCat.Nos 0 371 51/52Side mounting Insulated and separable
10 0 375 46 For 12 blocks with 5 mm pitch - brown10 0 375 47 For 12 blocks with 5 mm pitch - blue
Bridging combs for spring terminal blocks
Front mounting (automatic insertion), screwlessIsolatedRed
20 0 375 82 For 2 blocks with 10 mm pitch20 0 375 85 For 2 blocks with 12 mm pitch
1: Cat. No 0 371 51/52: upper level only Cat. No 0 372 56: lower level onlyCat. No 0 372 54: non shuntable2: Cat. No 0 371 56: lower level only3: Except for Cat.No 0 371 924: Except for Cat.No 0 371 87
Pack Cat.Nos Accessories for disconnect blocks
For screw and spring terminal blocks
Blade type levers
For open blocks Cat. Nos 0 371 80 and 0 372 80Manual disconnection for handle type, tool required for mini lever type
50 0 375 15 With handle lever for fuse cartridge 5 x 2050 0 375 16 Blue handle lever for neutral50 0 375 17 Grey handle lever50 0 375 18 Mini lever
Joining rods
For handle and mini lever20 0 375 21 For 2 blocks20 0 375 22 For 3 blocks
Blown fuse indicators
Clip directly onto blocks Cat.Nos 0 371 81,0 372 81 or handle lever 0 375 15 (with power off)
50 0 375 24 12/24/48 V= and A for block withfuse cartridge 5 x 20 with handle lever
50 0 375 25 110/250 VA for block with fuse cartridge5 x 20 with handle lever
0 371 80 + 0 375 15 + 0 375 25
0 372 81 + 0 375 24
0 375 15
0 375 16
0 375 17
0 375 18CAB 3 markers
0 375 62
0 375 95
0 375 52
0 375 89
0 375 54
Markers Cat.Nos 0 395 00/01/02
CAB 3 label holders Cat.No 0 383 92 for terminal blocks with screw connection
Equipotential bars Cat.Nos 0 375 40/42/44 for terminal blocks with screw connection
Bridging combs Cat.Nos 0 375 46/47 for 3 level terminal blocks with screw connection
Automatic bridging combs Cat.No 0 375 00 to 0 375 08 for terminal blocks with screw or spring connection
Technical characteristics p. 196
VikingTM 3 accessories for terminal blocks (continued)
193
Pack Cat.Nos Protective screens
1 poleFor screw terminal blocks 1 entry/1 outlet
10 0 375 65 5 and 6 mm pitch10 0 375 66 8 and 10 mm pitch10 0 375 67 12 and 15 mm pitch
Cut to lengthLength 1 mMounted on separation and insulation dividerFor screw terminal blocks 1 entry/1 outletCan be equipped with CAB 3 marking system for terminal blocks (p. 294)
10 0 375 68 5, 6, 8 and 10 mm pitch(divider Cat.No 0 375 60)
10 0 375 69 12 and 15 mm pitch(divider Cat.No 0 375 61)
Measurement accessories
For screw and spring terminal blocks10 0 375 271 Measurement socket for Ø4 mm plug
for blocks with 5, 6 and 8 mm pitch
For screw terminal blocks50 0 375 75 Measurement socket for Ø2 mm plug
for blocks with 10 mm pitch Cat.Nos 0 371 03/6320 0 375 76 Measurement socket for Ø4 mm plug
for blocks with 12 and 15 mm pitch Cat.Nos 0 371 04/05/64/65
10 0 375 77 Measurement socket for Ø4 mm plugfor disconnect block for measurement Cat.No 0 371 92
IP 2X safety tip adaptor10 0 394 45 Ø2 mm test plug - Retractable tube
For performing ad-hoc tests in accordance with regulations on the protection of workersFixes directly on the Ø4 mm plug
Pack Cat. Nos Shielding accessories
Ensure safe, simple connection of cable shielding
Shielding clampsFor screw and spring terminal blocks- mounted by pivoting on collector bar10 x 3 mm Cat.No 0 375 34- mounted on plate with M4 screws (supplied)- mounted on rail 4 with Cat.No 0 364 69
10 0 375 30 For cable Ø 3 to 8 mm10 0 375 31 For cable Ø 4 to 13.5 mm4 0 375 32 For cable Ø 10 to 20 mm
Shielding barFor screw and spring terminal blocksSteelLength 1 mFor use with end stops Cat.No 0 375 12
5, 6, 8 and 10 mm pitchConnected with 2.8 x 0.8 mm clips or welded onCapacity: 1 mm2
Shielding terminal block with end stops 0 375 12, bar 0 375 34 and clamps 0 375 30/31
1: Except for disconnect blocks with handle lever, screw terminalblock with LED and spring function blocks. 2 and 3-level terminalblocks: upper level only. Side by side installation of 2 measurment sockets is possible only with 8 mm pitch blocks
V2 polyamide according to UL 94, 960 °C according to IEC EN 60695-2-11Insulating material for terminal blocks: polyamide - 30° C to + 100° C
Connecting blocks
Blocks for protection conductor
Function blocks
Disconnect block for measurement
Wiring principle for measurement blocks Cat.No 0 371 92
Blocks for sensors and actuators/PNE
Stripped lengths (mm)
Schematic diagrams
Disconnect terminal blocks
Power according to IEC 60947-7-3
Approved by ATEX: LCIE 07 ATEX 0010 U-0081 II 1 or 2 G or D Ex e/i/tD/iD II
The terminal blocks with screw connection covered by this certificate are 1-, 2- and 3-level connecting terminal blocks, and blocks for protection conductor with metal base(1) (detailed list on p. 826) The main characteristics are: Operating temperature: - 30 °C to + 55 °C Maximum temperature of materials: + 85 °C
Working voltage acc. to EN 60079-7: 1-level terminal blocks: 500 V Blocks with 2 entries - 2 outlets: 250 V 2 and 3-level terminal blocks: 250 V
Rated current:
Cat.No 0 371 51: see blocks for sensorsIEC 60947-7-1, CSA no. 22-2 no. 158, UL 1059Ie: Rated current NF C 15100 table 52H, column 4
IEC 60947-7-2, CSA no. 22-2 no. 158, UL 1059 Ie: Rated current NF C 15100 table 52H, column 4 1: PEN terminal blocks
IEC EN 60947-7-1
IEC 60947-7-1/7-3, CSA no. 22-2 no. 158, UL 1059
IEC 60947-7-1/7-2, CSA no. 22-2 no. 158, UL 1059Ie: Rated current NF C 15100 table 52H, column 4
1: With or without blown fuse indicator Cat.No 0 375 25
Cat.No 0 371 53
Ammeter circuit Wattmeter circuit
Cat.No 0 371 56Diode for Cat.Nos 0 371 54/55 - 1N4007 type 1A- direct current = 1 A- peak inverse voltage 1000 V- inverse current 5 μA at 25 °C
Cat.No 0 371 54 Cat.No 0 371 55
Conductor cross-section (mm2)
2.5 4 6 10 16 35 70
Rated current (A) 18 23 30 42 57 93 145
Attestation of conformity of component for the customer is availableon request
1: Except for Cat.No 0 371 76
Cat.NosVoltage (V) Current (A) Nominal cross- section
Protection against fire and panic risks in public buildings/UTE C 12-201 guide
Art. EL 3, definitions: "Security installations are those that have to be put into or maintained in service to ensure the evacuation of the public or facilitate the intervention of the first-aid"
Art. EL 16, power supply circuits in security installations section 1a: "…the corresponding junction or deviation devices and their enclosures, except for the waterproofing systems, must satisfy the incandescent wire test defined in the standard in force, the temperature of the incandescent wire being 960 °C" Viking 3 terminal blocks satisfy the incandescent wire test 960 °C according to standard IEC 60695-2-11
Per circuit:2 x Disconnect blocks for measurementCat.No 0 371 924 x Measurement sockets for Ø4 mm plugCat.No 0 375 771 x End cap Cat.No 0 375 571 x Shunt with Ø4 mm plugs
10 x Disconnect blocks for measurementCat.No 0 371 9212 x Measurement sockets for Ø4 mm plugCat.No 0 375 771 x End cap Cat.No 0 375 573 x Shunts with Ø4 mm plugs
Normalposition
Testposition
Short-circuitposition
IEC 60947-7-1, CSA no. 22-2 no. 158, UL 1059 Dimensions
see e-catalogue
VikingTM 3 terminal blocks with spring connection
195
Characteristics
V2 polyamide according to UL 94, 960 °C according to IEC EN 60695-2-11Insulating material for terminal blocks: polyamide - 30° C to + 100° C
Connecting blocks
Stripped lengths (mm)
IEC 60947-7-1, CSA no. 22-2 no. 158, UL 1059Ie: Rated current NF C 15100 table 52H, column 4
IEC 60947-7-1/7-3, CSA no. 22-2 no. 158, UL 1059
IEC 60947-7-1, CSA no. 22-2 no. 158, UL 1059
IEC 60947-7-2, CSA no. 22-2 no. 158, UL 1059 Ie: Rated current NF C 15100 table 52H, column 4 1: PEN terminal blocks
Cat.No 0 372 54 Cat.No 0 372 55 Cat.No 0 372 56
Cat.Nos
Voltage (V) Current (A) Nominal cross- section
IEC CSA UL IEC CSA ULIEC
(mm2)CSA
(AWG)UL
(AWG)
0 372 54500 300 300 1 0.6 0.6
4 12 120 372 550 372 56 12 to 24 12 to 24 12 to 24 - - -
Cat.NosVoltage (V) Current (A) Nominal cross- section
Separate blocks Assembled blocks Separate blocks Assembled blocks
0 372 81 ou0 372 80 + 0 375 15(1)
4 W / 6.3 A 1.6 W / 6.3 A 1.6 W / 6.3 A -
Pvk = 4.75 W Pvk = 2 W Pv = 1.65 W -
Function blocks
Schematic diagrams
Blocks for protection conductor
Disconnect blocks
Approved by ATEX: LCIE 07 ATEX 0010 U-0081 II 1 or 2 G or D Ex e/i/tD/iD II
The terminal blocks with spring connection covered by this certificateare 1- and 2-level connecting terminal blocks, and blocks for protectionconductor with metal baseThe main characteristics are:Operating temperature: - 30 °C to + 55 °CMaximum temperature of materials: + 85 °C
Working voltage acc. to EN 60079-7: 1-level terminal blocks: 500 V 2-level terminal blocks: 250 V Rated current:
Conductor cross-section (mm2)
4 6 10 16
Rated current (A) 23 30 42 57
Attestation of conformity of compo-nent for the customer is availableon request
Power according to IEC 60947-7-3
(1): With or without blown fuse indicator Cat.No 0 375 25
Spring terminal pitch (mm) Rigid or flexible wire
58 to 126
810 8 to 1312 8 to 15
Diode for Cat.Nos 0 372 54/55 - 1N4007 type 1A- direct current = 1 A- peak inverse voltage 1000 V- inverse current 5 μA at 25 °C
Protection against fire and panic risks in public buildings/UTE C 12-201 guide
Art. EL 3, definitions: "Security installations are those that have to be put into or maintained in service to ensure the evacuation of the public or facilitate the intervention of the first-aid"Art. EL 16, power supply circuits in security installations section 1a: "…the corresponding junction or deviation devices and their enclosures, except for the waterproofing systems, must satisfy the incandescent wire test defined in the standard in force, the temperature of the incandescent wire being 960 °C" Viking 3 terminal blocks satisfy the incandescent wire test 960 °C according to standard IEC 60695-2-11
Blocks with 5 mm pitch/6 mm pitch
The active part of spring terminal blocks with 5 mm pitch is identicalto that of blocks with 6 mm pitch. The absence of an end cap is theonly difference between blocks with 5 mm pitch and blocks with6 mm pitch
Terminal blocks with 5 mm pitch are therefore 4 mm2 nominal / 32 Ablocks. Only a connection with end cap limits terminal blocks with 5 mm pitch to 2.5 mm2 / 24 A:
Spring terminal blocks with 5 mm pitch can therefore reduce thedimensions of 32 A terminal blocks connected with a rigid or flexibleconductor without end cap
Rigid conductor
Flexible conductor
Flexible conductorwith ferrule
Blocks with 5 mmpitch
6 mm2 / 32 A 4 mm2 / 32 A
2,5 mm2 / 24 A
Blocks with 6 mmpitch
4 mm2 / 32 A
End cap + block with 5 mm pitch Block with 6 mm pitch and built-in divider
Pack Cat.Nos Insulated aluminium/copper power terminal blocks
For aluminium/copper cables, copper bars or cable lugs (see selection chart p. 198)Direct connection of cableInsulation and protection against direct contact without additional accessories (built-in dividers and covers)Pre-cut removable covers for adjustment to the various connection modesFixed using metal clip for rails 4 15 mm depth and 4 EN 60715 15 mm depth, or on plate with screwsPermits the use of Cab 3, Duplix markersTest via test plug closed coversBlocks with identical pitch can be joined using a threaded rodShunting possible with Cat.Nos 0 394 46/47
Cable - cableRigid or flexible
cable (mm²)Rigid or flexible
cable (mm²) Pitch (mm)
5 0 390 10 Al/Cu 35 to 120 Cu 35 to 70 425 0 390 11 Al/Cu 70 to 300 Cu 70 to 150 55
Bridging the gap between the enclosure and external cables
Al/Cu direct connection without cable lug
0 390 72
CAB 3 marking system
p. 201
Al/Cu distribution boxes
p. 132
End stops
p. 191
VikingTM 3 power terminal blocks
198
Cat.Nos 0 390 71/72/73/74
A
B'
C
B
A mini
A maxi
E C
HGF
D
Selection chart
Cat.Nos 0 390 10/11Cable Al/Cu - Cable Cu
Cat.Nos 0 390 17/18Cable lug - Cable Cu
Cat.Nos 0 390 13/14/15Cable lug - cable lug
Cat.Nos 0 390 20/21Cable Al/Cu - Cable lug
AWG cable cross-sections
■ Characteristics of bare terminal blocks
■ Characteristics of insulated Al/Cu terminal blocks
Separation barriers dimensions (mm)
Conform to IEC EN 60947-7-1Insulation voltage Ui: 1000 V AC-DCFire resistance: - 960 oC acc. to IEC EN 60695-2-11
- V2 according to UL 94Insulating material: polyamide - 30 °C to + 100 °C
Conform to IEC EN 60947-7-1, UL 1059, UL 486 E and CSA C 22-2 n° 158Insulation voltage Ui: 1000 V AC-DCImpulse voltage Uimp: 12 kVOvervoltage category: 4Use in pollution atmosphere 3Fire resistance:- 960 °C (except cover) acc. to IEC EN 60695-2-11- V2 according to UL 94Insulating material: - polyamide body - 30 °C to + 100 °C - polypropylene cover -25 °C to + 100 °CIK 04
For Starfix crimping toolFor dispensing strips of ferrules in Starfix crimping tools Cat.Nos 0 376 08/09/10For ferrules cross-section (mm²) Colour
10 0 376 46 0.25 and 0.34 yellow10 0 376 47 0.5 to 2.5 red10 0 376 48 4 and 6 orange
0 376 47 Example of simple/double ferrules on wires
Example of different wires and ferrules
Viking 3 terminal blocks and accessories
p. 183 to 198
CAB 3TM marking systemfor wiring and Viking 3 terminal blocks
Marking label sheetsfor Viking 3 terminal blocks
201
Pack Cat.Nos Markers for wiring 0.5 to 1.5 mm2 cross-section and terminal blocks
Strips of 20 markers (price per marker) Numbers: black on white background (available in black on yellow background on request)
240 0 381 50 01 to 20240 0 381 51 21 to 40240 0 381 52 41 to 60240 0 381 53 61 to 80240 0 381 54 81 to 100240 0 381 55 Blank
Markers for wiring 1.5 to 2.5 mm2 cross-section and terminal blocks
Strips of 20 markers (price per marker) Numbers: black on white background (available in black on yellow background on request)
240 0 381 60 01 to 20240 0 381 61 21 to 40240 0 381 62 41 to 60240 0 381 63 61 to 80240 0 381 64 81 to 100240 0 381 65 Blank
For marking wiring or Viking 3 terminal blocks
0 395 05 on Viking 3 terminal blocks
0 395 20
0 395 98
Same markers for cable and terminal blocks 0 381 63 mounted on Viking 3
terminal blocks
For marking Viking 3 terminal blocks
0 381 51
0 381 51
0 381 64
0 381 64
Pack Cat.Nos Blank markers
Displayed by sheet of 100 pre-cut markers Manual marking (price per marker)
1000 0 395 00 For blocks 5 mm pitch1000 0 395 01 For blocks 6 mm pitch1000 0 395 02 For blocks 8 mm pitch
Numbers
Correct reading direction with the marker in horizontal position. Price per marker.
Pitch of 5 mm1000 0 395 05 From 1 to 10 (10 times)1000 0 395 06 From 11 to 20 (10 times)1000 0 395 07 From 21 to 30 (10 times)1000 0 395 08 From 31 to 40 (10 times)1000 0 395 09 From 1 to 50 (2 times)1000 0 395 10 From 1 to 1001000 0 395 11 From 101 to 200
Pitch of 6 mm1000 0 395 15 From 1 to 10 (10 times)1000 0 395 16 From 11 to 20 (10 times)1000 0 395 17 From 21 to 30 (10 times)1000 0 395 18 From 31 to 40 (10 times)1000 0 395 19 From 1 to 50 (2 times)1000 0 395 20 From 1 to 1001000 0 395 21 From 101 to 200
Black felt tip pen
10 0 395 98 Indelible for marking
Technical characteristics p. 203
Viking 3 terminal blocks
p. 183
CAB 3TM marking systemmarkers for wiring and Viking 3 terminal blocks
202
Pack Cat.Nos Markers for wiring 0.15 to 0.5 mm2 and 0.5 to 1.5 mm2 cross-section and terminal blocks
On Viking 3 terminal blocks - 4 markers 0.15 to 0.5 mm2 max - 3 markers 0.15 to 1.5 mm2 max.Pack:- Up to 0.5 mm2: strips of 25 markers From 0.5 mm2 to 2.5 mm2: strips of 30 markersPrice per marker
6.5 mm wide fingers with a 6 mm spacing Accepts up to 6 mm2 without breaking side wall fingerTwo pre-scored lines allow removal of fingers Bump on side wall fingers help cabling Rounded fingers prevent injury during cablingConform to EN 500 85 parts 2 and 3 Plastic cable ducting (base + cover)Side perforations at intervals of 12.5 mmLength: 2 m
Pack Cat.Nos Grey RAL 7035 halogen free
PC/ABSWidth x Height
(mm)Capacity
(mm2)
601 6 362 00 25 x 25 391561 6 362 01 25 x 40 720561 6 362 02 25 x 60 1159481 6 362 06 40 x 40 1245481 6 362 07 40 x 60 2007401 6 362 08 40 x 80 2717321 6 362 12 60 x 60 3115321 6 362 13 60 x 80 4216241 6 362 17 80 x 80 5715161 6 362 25 120 x 80 8729
Pack Cat.Nos Grey RAL 7030
PVCWidth x Height
(mm)Capacity
(mm2)
321 6 360 95 15 x 25 264401 6 360 96 15 x 40 455601 6 361 00 25 x 25 391561 6 361 01 25 x 40 720561 6 361 02 25 x 60 1159401 6 361 03 25 x 80 1600561 6 361 05 40 x 25 692481 6 361 06 40 x 40 1245481 6 361 07 40 x 60 2007401 6 361 08 40 x 80 2717241 6 361 09 40 x 100 3354321 6 361 11 60 x 40 1932321 6 361 12 60 x 60 3115321 6 361 13 60 x 80 4216241 6 361 14 60 x 100 5216241 6 361 15 80 x 40 2647241 6 361 16 80 x 60 4200241 6 361 17 80 x 80 5715201 6 361 18 80 x 100 7078241 6 361 19 100 x 40 3363241 6 361 20 100 x 60 5307161 6 361 21 100 x 80 7215161 6 361 22 100 x 100 8960161 6 361 24 120 x 60 6403161 6 361 25 120 x 80 8729121 6 361 23 150 x 100 13683
1: Number of meters in pack
Technical characteristics p. 208
Accessories,
p. 207
1: Number of meters in pack
Lina 25TM cable ducting
207
Pack Cat.Nos Linafix isulating fixing accessories
Material polyamide 6/6Enable fixing of cable ducting on any support by 1/4 turn
20 0 367 00 On chassis-railHolds the ducting in place vertically
20 0 366 42 On doorFits under control and signalling auxiliaries Osmoz (Ø22)
10 0 366 43 On Lina 25 uprightsDouble adjustment to enable alignment with the perforations at the bottom of cable ducting Can be used to fix vertical or horizontal ducting(possible reinforcement with rail 2, 15 mm depth)To be clipped on
100 0 366 46 On plain platesplastic rivet length 12 mm for solid plates up to 30 / 10th
Drilling Ø: 5.5 to 6 mm500 0 366 44 On plain plates, Lina 12.5 and
perforated plates, Lina 25 for cabinetsReinforced plastic rivet Ø6 mmDrilling Ø: 6.5 mm
100 0 347 45 Screw caps H 4.8 x 16 mm self-drilling,self-tapping for Ø3.3 mm
200 0 347 50 Screw cover, for isolating screws head Cat.No 0 347 45 inside the trunking
50 0 367 01 Cable retainerTo clip-on the fingers
Pack Cat.Nos Lina 25 ducting
RAL 2525 blue PVC Conform to EN 50085-2-36.5 mm wide fingers with a 6 mm spacingAccepts up to 6 mm2 without breaking side wall fingersTwo pre-scored lines allow removal of fingersBump on side wall fingers help cablingRounded fingers prevent injury during cablingConform to EN 50085 parts 2 and 3Plastic cable ducting (base + cover)Side perforations at intervals of 12.5 mmLength: 2 mWidth x height (mm)
601 0 362 00 25 x 25561 0 362 01 25 x 40561 0 362 02 25 x 60401 0 362 03 25 x 80561 0 362 05 40 x 25481 0 362 06 40 x 40481 0 362 07 40 x 60401 0 362 08 40 x 80 321 0 362 11 60 x 40321 0 362 12 60 x 60321 0 362 13 60 x 80241 0 362 16 80 x 60241 0 362 17 80 x 80161 0 362 25 120 x 80
Lina 25 cutter tool
1 0 367 10 For a straight break of side wall fingers
Sleeving
Braided sleevingBlack polyesterSupplied in 50 m roll in dispenser boxwith an indicator 3 m before end
Ø of roll Ø variations
1 0 366 38 20 mm 10 to 30 mm1 0 366 39 30 mm 18 to 54 mm
Spiral sleevingColourless
25 6 361 78 Ø12 mm25 6 361 83 Ø22 mm
Black felt-tip pen
10 0 395 98 Black felt-tip pen indelible for marking
0 367 10
0 395 98 Manually separable trunking Side wall fingers can be cut using the Lina 25 cutter toolCat.No 0 367 10
0 362 01
0 362 12
0 362 13
1: Number of metres in pack
Technical characteristics p. 208
Transcab and Lina 25TM cable ducting
208
0 366 41
Width 25 to 60 mm(Transcab and Lina 25)
Width 150 mm (Transcab)
12.5 12.512.5 25
14 8
4.5
wid
th fro
m 2
5 to 6
0
6.5
4.5
wid
th 1
50
12.5 12.512.5 25
6.5
6.5
6.5
6.5
6.5
25
25
25
25
14 8
Width 15 mm (Transcab)
Width 80 to 120 mm(Transcab and Lina 25)
12.5 8 wid
th 1
5
4.5
25
5012.5 12.5
12.5 12.512.5 25
14 8
4.5
wid
th fro
m 8
0 to 1
20
6.5
6.5
6.52
525
6.25 12.5
6 1.8
Dimensions (continued)
Norm EN 50085-2-3
Classification of Transcab and Lina 25 cable ducting
Lina 25 installation
Lina 25 accessories installation
Linear positioning Cut at two different levels for cable ducting
"T" junction
Calculating the ducting usable cross-section
Graph for H 05 V-K and H 07 V-K cables with 0.75 packing coefficient
Example :
150 conductors 0.75 mm2 2 cross-section and 120 conductors 1.5 mm2 2 cross-section Makes a total of 2930 mm2
The correct cable ducting is Cat.No 0 362 12, 60 x 60, with a capacity of 3115 mm2
8000
7079
8730 9000
7000
6000 5716
5216 5000
4216 4200
3115
3354
3000
2717
2000
300 391
1932 1246
2008
1159
692
720 1000 730
460
100 200 300 400 500 600 700 800 900
10 m
m2
6 m
m2
4 m
m2
2.5
mm
2
1.5
mm
2
1 m
m2
0.75
mm2
Cat.No 0 362 25
Cat.No 0 362 17
Cat.No 0 362 13
Cat.No 0 362 16
Cat.No 0 362 12
Cat.No 0 362 08
Cat.No 0 362 07
Cat.No 0 362 11
Cat.No 0 362 02Cat.No 0 362 06
Cat.No 0 362 01
Cat.No 0 362 05Cat.No 0 362 00
8960
Usable cross-section (mm
2)
Number of conductors
Fixing on perforated plate
Cat.Nos A (mm) B (mm) C (mm)
0 362 00 25 25 6
0 362 01 25 40 5
0 362 02 25 60 6
0 362 03 25 80 6
0 362 05 40 25 10
0 362 06 40 40 10
0 362 07 40 60 10
0 362 08 40 80 10
0 362 11 60 40 10
0 362 12 60 60 10
0 362 13 60 80 10
0 362 16 80 60 10
0 362 17 80 80 10
0 362 25 120 80 10
Cat.Nos A (mm) B (mm)
6 360 95 15 25
6 360 96 15 40
6 361 00/ 6 362 00 25 25
6 361 01/ 6 362 01 25 40
6 361 02/ 6 362 02 25 60
6 361 03 25 80
6 361 05 40 25
6 361 06/ 6 362 06 40 40
6 361 07/ 6 362 07 40 60
6 361 08/ 6 362 08 40 80
6 361 09 40 100
6 361 11 60 40
6 361 12/ 6 362 12 60 60
6 361 13/ 6 362 13 60 80
6 361 14 60 100
6 361 15 80 40
6 361 16 80 60
6 361 17/ 6 362 17 80 80
6 361 18 80 100
6 361 19 100 40
6 361 20 100 60
6 361 21 100 80
6 361 22 100 100
6 361 24 120 60
6 361 25/ 6 362 25 120 80
6 361 23 150 100A
4
C C
B
(marking area)
0 366 40
0 366 42
0 367 01
Fixing on rail
Cable retainer
Fixing on door
Dimensions
Transcab cable ducting Lina 25 cable ducting
6.3 Minimum storage and transport temperature
- 25 °C
6.3 Maximum operating temperature
+ 60 °C
6.101 Mounting position Vertical or horizontal
Osmoz control and signalling units: non-illuminated heads
Without engraving10 0 243 15 Round - standard model10 0 243 16 Round - large model10 0 243 18 Square - standard model10 0 243 19 Round - standard model for twin touch
Technical characteristics p. 214 and e-catalogue
Osmoz control and signalling units
214
- Climatic resistance: - conform to IEC 60068-2-3 (constant humid heat) - conform to IEC 60068-2-30 (cyclical damp heat)- Degree of protection conform to IEC 60529 - IP 66 for standard heads - IP 67 for shrouded heads - IP 66 for equipped control stations - IP 20 at the rear of the panel for contact blocks and one piece pilot lights - Nema 4x, 12 and 13 for heads and control stations- Protection against mechanical shocks conform to IEC 50102:IK 05 illuminated and non illuminated headsIK 07 empty control station- Protection against electrical shocks:Class II according to IEC 60947-5-1- Tightening torque: head nut: recommended 3 N.m terminals: max. 1.2 N.mcULus and Bureau Veritas approvals
Contact blocks (for non illuminated heads)
Rated insulation voltage:Degree of pollution 3690 V according to IEC/EN60947 for flush block with screw terminals or spring terminals600 V AC according to UL 508
NC contacts:Positive opening conform to IEC/EN 60947-5-1
Rated impulse withstand voltage Uimp: 6kV contact blocks
Convention therminal conform to IEC 60947-5-1current in free air conditions:
AC: 10 ADC: 2.5 A
Electrical performance:- AC according to - DC according toIEC 60947-5-1 IEC 60947-5-1 AC15 - A 600 DC13 - Q 600 Ue = 120 V, Ie = 6 A Ue = 125 V, Ie = 0.55 A Ue = 240 V, Ie = 3 A Ue = 250 V, Ie = 0.27 A Ue = 380 V, Ie = 1.9 A Ue = 400 V, Ie = 0.15 A Ue = 480 V, Ie = 1.5 A Ue = 500 V, Ie = 0.13 A Ue = 500 V, Ie = 1.4 A Ue = 500 V, Ie = 0.1 A Ue = 500 V, Ie = 1.2 A - Electrical durability1 million cycles for: - AC15 - B 300 Ue = 120 V, Ie = 3 AUe = 240 V, Ie = 1.5 A - DC13 - R 300 Ue = 125 V, Ie = 0.22 A Ue = 250 V, Ie = 0.1 A
Connection capacity (rigid or flexible wire)without ferrule: 2 x 0.5 mm2 to 2 x 2.5 mm2
with ferrule: 2 x 0.5 mm2 to 2 x 1.5 mm2
LED blocks and LED pilot lights (for illuminated heads)
Rated insulation voltage:Degree of pollution 3300 V according to IEC/EN60947-5-1
Rated insulation withstand voltage Uimp:4kV conform to IEC/EN 60947-1
Operating voltage:12 to 24 V AC/DC130 V AC } ± 10 %230 V AC
Frequency: 50 or 60 Hz
Lifetime at rated supply voltage:Red and yellow: 100,000 hours at 25°COther colours: 50,000 hours at 25°C
Consumption of LED blocks:Voltage: - 24 V: 25 mA ± 20% - 48 V: 15 mA ± 10% - 130 V: 20 mA ± 10% - 230 V: 16 mA ± 30%
Technical characteristics
Head with 1 contact
block on 1 position clip
Head with 1 or 2 contact
blocks on a 3 position clip
Head with 3 contact blocks
on a 3 position clip
Head with 4 or 5 contact
blocks on a 5 position clip
Head with 4, 5 or 6 contact
blocks 2nd level of contact blocks
stacked directly on first row
(3 position clip)
Mounting
Non illuminated
Illuminated
Pilot light on 1
position clip
Illuminated head with LED
and 1 or 2 contact blocks
on 3-position clip
Illuminated head with LED and
3 or 4 contact blocks 2nd level of
contact blocks stacked directly
on first row (3 position clip)
Illuminated head with LED on
transformer supply with 1 or 2
contact blocks on 3 position clip
Illuminated head with LED and
3 or 4 contact blocks on
5 position clip
Illuminated blocks
Dimensions
see e-catalogue
215
SOLUTIONS FOR POWER CONNECTION
P17 TEMPRA PROsuitable for all
environments From 16 to 32 A
2 P+E / 3 P+E / 3 P+N+E
From 100 to 500 VA 50/60 Hz
IK 09 - Polyamide 6
Conform to IEC 60 309-1 and 2
Screw connection
Unlocked by pressing with a screwdriver. Marking indicates the location for the locking clip.
Opened by turning the 2 parts in opposite directions.
To solve the problem of limited space, the surface mounting sockets offer 2 different mounting positions (5° or 25°) which allow users to adapt to the space available without changing the box.
2 MOUNTING POSITIONSQUICK OPENING/CLOSING SYSTEM
IP44
Sockets for internal and
external use, protected
against projections of
water (but not exposed
to direct jets).
IP66/67
Weatherproof sockets that
can withstand temporary
immersion (unplug in
torrential rain, floods, etc.).
FOUR FUNCTIONS AVAILABLE
100 to 130 VA 50/60 Hz Consult us
200 to 250 VA 50/60 Hz
380 to 415 VA 50/60 Hz
440 to 460 VA 50/60 Hz Consult us
480 to 500 VA 50/60 Hz Consult us
Straight plugs Mobile sockets Panel mountingsockets
Surface mountingsockets
25°5°
NEW
216
SOLUTIONS FOR POWER CONNECTION
P17 TEMPRA PROensuring ease of use
and safety
2 3
5
1
4
SAFETY
Connection terminals compliant
with standards IEC 60 309 1 & 2
Production sites certified according to
ISO 14001 and ISO 9001
Very high resistance to chemical
products.
Plugs and sockets made of polyamide 6
Anti-corrosion treated screws, stainless
steel springs for the socket covers
Resistant to temperatures of -25°C to
+40°C
ENVIRONMENT
Halogen-free recyclable materials
(silicone, PVC)
Grouped packaging in boxes
PEP products
(Eco Passport)
Captive cable grip with anti-vibration
system holds the cable in place
permanently.
To solve the problem of limited space, the surface mounting sockets
offer 2 different mounting positions (5° or 25°) which allow users
to adapt to the space available without changing the box.
CABLE GRIP2 MOUNTING POSITIONS1 2
AN INNOVATIVE
DESIGN THAT
COMPLIES WITH
STANDARDS
IEC 60309-1
AND 2 AND
RESPECTS THE
ENVIRONMENT
25°5°
Information engraved on the ring cover of IP66/67 products means the
user can check quickly whether it is in the open or closed position.
Marking area on the shutter of the sockets and on the upper part of the
plugs allows easy identification by the user.
Gripping areas on the body of
the mobile products and the
cable grip.
EASE OF HANDLING POSITION MARKING3 5
For easier connection/
disconnection. Cover held
open on panel sockets and
surface mounting sockets.
OPENING LEVER4
NEW
P 17 Tempra Pro IP 44 - LV 16 and 32 Aselection chart
Rubber For plugs and appliance inlets:10 0 521 25 2P+E - 16 A5 0 521 26 3P+E - 16 A5 0 521 27 3P+N+E - 16 A / 2P+E and 3P+E - 32 A5 0 527 99 3P+N+E - 32 A
AVAILABLESEPT 2014
P 17 Tempra - domestic pin configuration16 A - 250 VA
P 17 Tempra IP 44 - ELV 16 and 32 A
220
0 576 69
0 521 05 + 0 772 11
Technical characteristics p. 224 Technical characteristics p. 225
Pack Cat.Nos Surface mounting sockets
16 A 32 A 20/25 V±5 0 552 06 0 552 56 2P
Panel mounting sockets
16 A 32 A 20/25 V±5 0 552 45 0 552 95 2P
Straight plugs
16 A 32 A 20/25 V±5 0 552 21 0 552 71 2P
Mobile sockets
16 A 32 A 20/25 V±5 0 552 31 0 552 81 2P
Appliance inlets
16 A 32 A 20/25 V±5 0 552 41 0 552 91 2P
Pack Cat.Nos Panel mounting sockets
Domestic pin configuration German standard sockets IP 54 cover closed - IP 44 connected IK 09 according to IEC 62262 and EN 62262 2P+E 250 VA Material: plastic Self-extinguishing: 850 °C
Panel mounting sockets with small flangeCan be fixed only on plain faceplates Cat.Nos 0 577 15/16 (p. 229)
20 0 576 69 White panel mounting sockets20 0 576 75 Blue panel mounting sockets with shutters
Panel mounting socketsCan be fixed on pre-cut or plain faceplate for combined units (p. 229), flush-mounting boxes Cat.Nos 0 577 21/22
20 0 576 72 Blue panel mounting sockets20 0 576 76 Blue panel mounting sockets with shutters
LV: 100/130 VA 200/250 VA 380/415 VA 440/460 VA 480/500 VA
Frequency
LV: 50/60 Hz - 60 Hz
Rated current
16 A
32 A
63 A
125 A
Number of poles
2P
3P
2P+E
3P+E
3P+N+E
PRODUCT TYPE
Panel mounting socket
Surface mounting socket
Straight plug
Angled plug
Mobile socket
Appliance inlet
QUANTITY OF IDENTICAL PRODUCTS
Panel mounting socket3P+E 32 A - 200/250 VA
Surface mounting socket2P+E 16 A - 380/415 VA
Appliance inlet2P+E 16 A - 380/415 VA
Quotation within
72
hours
2
YOUR CONTACT DETAILS
Company name: ................................................... .......................................................................................
Name and forname: ........................................... .......................................................................................
Company name: ................................................... .......................................................................................
Name and forname: ........................................... .......................................................................................
Company name: ................................................... .......................................................................................
Name and forname: ........................................... .......................................................................................
Individual protection device (on each socket outlet): MCB RCBO
QUANTITY OF IDENTICAL COMBINED UNITS
P 17 combined unitequipped with 4 domesticpin configuration sockets
P 17 combined unit equipped with 2 IEC panel mountingsockets and 3 domestic pinconfiguration sockets
Quotation within
72
hours
3
YOUR CONTACT DETAILS
Company name: ................................................... .......................................................................................
Name and forname: ........................................... .......................................................................................
Company name: ................................................... .......................................................................................
Name and forname: ........................................... .......................................................................................
16 A: max. 1 x 4 mm2 rigid32 A: max. 1 x 10 mm2 rigid
16 A: max. 1 x 2.5 mm2 rigid32 A: max. 1 x 6 mm2 rigid
16 A: max. 1 x 2.5 mm2 flexible32 A: max. 1 x 6 mm2 flexibleIP 44 according to IEC and EN 60529IK 08 according to EN 50102 for interlocked switched sockets withsmall flangeIK 09 according to IEC 62262 and EN 62262Material: polyamide 6Self-extinguishing: 850 °C (support of active parts) / 650 °C (plastichousing)- 25 °C to + 40 °C according to IEC 60309-1
■ Characteristics
■ Dimensions
Surface mounting sockets (p. 219)
Panel mounting sockets inclined outlet (p. 219)
Appliance inlets (p. 219)
Interlocked switched sockets with small flange (p. 219)
Panel mounting socket straight outlet small flange (p. 219)
3P+E 146 to 157 109.5 to 120.5 34 67 55 7.10 to 15.5
3P+N+E 163 to 176 126.5 to 139.5 38 76 65 8 to 20
LV 32 A
2P+E 172 to 185 127 to 140 40 78 65 8 to 20
3P+E 172 to 185 127 to 140 40 78 65 8 to 20
3P+N+E 179 to 189 133 to 143 45 86 71 11.9 to 22.2
A B C D ØLV 16 A
2P+E 156 to 167 59 81 50 6.5 to 14
3P+E 157 to 168 65 88 55 7.10 to 15.5
3P+N+E 175 to 188 72 94 65 8 to 20
LV 32 A
2P+E 184 to 197 73 99 65 8 to 20
3P+E 184 to 197 73.5 99 65 8 to 20
3P+N+E 190 to 203 79.5 105 71 11.9 to 22.2
Cat.Nos 0 576 69/75
Cat.No 0 521 05
Cat.No 0 539 48
Cat.No 0 577 21 Cat.No 0 577 22
Cat.Nos 0 576 72/76
62
Ø 4
3
50
25
38
26 17
67
Ø 4.5
Ø 44
62
Ø 4
3
75
25
60
Ø 4.5
Ø 44
26 67
17
84
60
124
56
160
255
109
70
70
160140
99
84
84 34
EC
D
A
B
Ø
D
BC
A
Ø
P 17 Tempra IP 44 - ELV 16 and 32 A
225
84
73
84
72
Ø 4.3
101
103
134.5
19
M 25
Weight (kg) = 0.167
84
84 33 32.5
4.5
10°
83
Ø 63
Ø 4.2
70
35
70
72
72
117.5
84
84 70
34
CE (M25)
Ø 4.3 mm
10°
■ Dimensions
■ Dimensions ELV 16 and 32 A■ Characteristics
Terminal connection:Max. 1 x 10 mm2 (rigid for fixed products flexible for mobile products)IP 44 according to IEC 60529 and EN 60529IK 09 according to IEC 62262 and EN 62262Material: plasticSelf-extinguishing: 850 °C (support of active parts) / 650 °C (plastic housing)Temp. rating: - 25 °C to + 40 °CConform to IEC 60309-1 / IEC 60309-2 and EN 60309-1 / EN 60309-2
Surface mounting sockets (p. 220)
Straight plugs (p. 220)
Mobile sockets (p. 220)
Panel mounting sockets (p. 220)
Appliance inlets (p. 220)
Cat.Nos 0 552 06/56
Cat.Nos 0 552 45/95
Cat.Nos 0 552 41/91
75.956.3
154.5
56.3 54.7
151
Weight (kg) = 0.132
Weight (kg) = 0.16
P 17 Tempra Pro IP 66/67 - LV 16 and 32 A
226
■ Dimensions
■ Characteristics
Terminal connection:
16 A: max. 1 x 4 mm2 rigid - 32 A: max. 1 x 10 mm2 rigid
16 A: max. 1 x 2,5 mm2 flexible - 32 A: max. 1 x 6 mm2 flexible
16 A: max. 1 x 2.5 mm2 rigid - 32 A: max. 1 x 6 mm2 rigidIP 66/67 according to IEC 60529 and EN 60529IK 09 according to IEC 62262 and EN 62262Material: polyamide 6Self-extinguishing: 850 °C (support of active parts) / 650 °C (plastic housing)Temp. rating: - 25 °C to + 40 °CConform to IEC 60309-1 and IEC 60309-2