[email protected]www.itwcp.co.uk Technical Helpline UK: 0800 731 4924 Technical Helpline ROI: 1 800 882 388 Epomax With ATP Zinc Coated Steel & Stainless Steel Applications ¬ Fixing steel framed structures ¬ Fixing machinery (resistant to vibration) ¬ Insulated fixings (public lighting, cable trays, etc) (high dielectric strength, 10 000 volts, with EPCON 530/200 resin) ¬ Waterproof fixings (dams, etc) ¬ Fixing protective barriers and safety rails Material ¬ Body ATP: S 300 pb NFA 35561 ¬ Body ATP (stainless steel A4): X2Cr Ni Mo 17-12-2 ¬ Centering cap ATP high density PE Installation ¬ Female chemical anchoring for heavy loads SPIT ATP Max. Min thick Threaded Depth of Ø thread Drilling Ø drill Total rod Total Max. Max. Eurocode Eurocode anchor of base length threaded depth bit length capsule tighten tighten Zn st. steel depth material start length torque torque 5.8 A4 screw 8.8 screw (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Nm) (Nm) h ef h min I 2 LD d h O d O L L p T inst T inst ATP M8x60 60 100 20 4,5 8 65 14 60 80 10 15 062770 062860 ATP M10x65 65 100 25 7 10 70 20 65 85 22 30 062480 062960 ATP M12x75 75 100 30 8 12 75 24 75 107 36 70 062760 063100 ATP M12x120* 120 180 38 5 12 125 18 120 107 36 70 062500 - ATP M16x125 125 180 40 9,5 16 130 28 125 162 80 120 052800 - ATP M20x170 170 225 50 12,5 20 175 35 170 200 120 200 062810 - Technical data M8 M10 M12 M16 M20 Body ATP in zinc coatd steel f uk (N/mm 2 ) Min. tensile strength 520 520 520 520 520 f yk (N/mm 2 ) Yield strength 420 420 420 420 420 Body ATP in stainless steel f uk (N/mm 2 ) Min. tensile strength 650 650 650 - - f yk (N/mm 2 ) Yield strength 350 350 350 - - Anchor mechanical properties EPOMAX and Epcon C8 resin can be used with ATP female studs * No ETA approval Ambient temperature (°C) Working time Curing time Dry concrete Wet concrete 40°C 1 min 30 min 60 min 30°C 3 min 35 min 1 hour 10 min 20°C 6 min 40 min 1 hour 20 min 10°C 11 min 60 min 2 hours 0°C 22 min 3 hours 30 min hours Working time and curing time Note: minimum installation temperature: -5°C *Premium cleaning: ¬ Blow with compressed air X2 ¬ Clean with a brush attached to a drilling machine X2 ¬ Blow with compressed air X2 Premium cleaning* 1/4 European Technical Approval ETA Option 7 n° 05/0111 (EPOMAX) n° 05/0112
4
Embed
Epomax With ATP Zinc Coated Steel & Stainless · PDF fileTechnical data M8 M10 M12 M16 M20 ... Screw grade A4-70 V ... Epomax With ATP Zinc Coated Steel & Stainless Steel 4/4
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
¬ Body ATP (stainless steel A4): X2Cr Ni Mo 17-12-2
¬ Centering cap ATP high density PE
Installation
¬ Female chemical anchoring for heavy loads
SPIT ATP Max. Min thick Threaded Depth of Ø thread Drilling Ø drill Total rod Total Max. Max. Eurocode Eurocode anchor of base length threaded depth bit length capsule tighten tighten Zn st. steel depth material start length torque torque 5.8 A4 screw 8.8 screw
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Nm) (Nm) hef hmin I2 LD d hO dO L Lp Tinst Tinst
M8 M10 M12 M16 M20 Body ATP in zinc coatd steel fuk (N/mm2) Min. tensile strength 520 520 520 520 520 fyk (N/mm2) Yield strength 420 420 420 420 420 Body ATP in stainless steel fuk (N/mm2) Min. tensile strength 650 650 650 - - fyk (N/mm2) Yield strength 350 350 350 - -
Anchor mechanical properties
EPOMAX and Epcon C8 resin can be used with ATP female studs
* No ETA approval
Ambient temperature (°C)
Working time Curing time
Dry concrete Wet concrete40°C 1 min 30 min 60 min 30°C 3 min 35 min 1 hour 10 min 20°C 6 min 40 min 1 hour 20 min 10°C 11 min 60 min 2 hours 0°C 22 min 3 hours 30 min hours
Working time and curing time
Note: minimum installation temperature: -5°C
*Premium cleaning:
¬ Blow with compressed air X2
¬ Clean with a brush attached to a drilling machine X2
Epomax With ATP Zinc Coated Steel & Stainless Steel 2/4
* All published performance values on pages 76 - 79 are for Epomax Vinylester Resin. For Epcon C8 performance values contact the Technical Helpline.
Anchor size M8x60 M10x65 M12x75 M12x120 M16x125 Drilling Ø (mm) 14 20 24 18 28 Drilling depth (mm) 65 70 80 125 130 Number of fixings for one cartridge EPCON C8 450 ml* 112 42 30 34 11 EPOMAX 150 ml 31 11 8 9 3 EPOMAX 345 ml 72 27 19 22 7 EPOMAX 380 ml 80 30 21 24 8
Number of fixings per cartridge
Ultimate (NRu,m, VRu,m) / characteristic loads (NRk, VRk) in kNMean Ultimate loads are derived from test results in admissible service conditions, and characteristic loads are statistically determined.
Screw grade A4-70 VRec 5,8 9,3 13,5 13,5 25,1 - γMs 5.8 = 1,25 - γMs 8.8 = 1,25 for M8 to M12 γMs 8.8 = 1,5 for M16 to M20 - γMs A4-70 = 1,56
*Derived from test results
*Derived from test results
N NRd
Rk=*
γ McV V
RdRk=
*γ Ms
N NRec
Rk=*
γ γM F
V VRec
Rk=*
.γ γM F
The loads specified on this page are derived from internal test results. For results derived from CC Methodology, please see overleaf.The data given in the pages “CC - Method” have to be applied.