Top Banner
Environmental Systems
104

Environmental Systems

Dec 30, 2015

Download

Documents

briar-thomas

Environmental Systems. Oxygen Systems. What are three basic configurations of oxygen systems?. Oxygen Systems. What are three basic configurations of oxygen systems? Continuous-flow Diluter-demand Pressure-demand. Continuous-flow. Name three types of Continuous-flow oxygen systems?. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Environmental Systems

Environmental Systems

Page 2: Environmental Systems

Oxygen Systems

• What are three basic configurations of oxygen systems?

Page 3: Environmental Systems

Oxygen Systems• What are three basic

configurations of oxygen systems?–Continuous-flow

–Diluter-demand

–Pressure-demand

Page 4: Environmental Systems

Continuous-flow• Name three types of

Continuous-flow oxygen systems?

Page 5: Environmental Systems

Continuous-flow• Constant flow

• Adjustable-flow• Altitude-compensated

Page 6: Environmental Systems

Oxygen Systems

• What is the most popular system in modern aircraft?

• Altitude-compensated

Page 7: Environmental Systems

Oxygen Masks

• Name three types of oxygen masks?

Page 8: Environmental Systems

Oxygen Masks

• Name three types of oxygen masks?–Oronasal rebreather

–Cannula oxygen breathing device

–Quick-donning

Page 9: Environmental Systems

Oxygen Systems

• With an altitude-compensated regulator and an oronasal rebreather, when will the bag fully inflate?

• Why?

Page 10: Environmental Systems

Oxygen Systems

• High Altitudes

• Decreased atmospheric pressure and increased oxygen flow rate

Page 11: Environmental Systems

Oxygen Systems

• In a continuous-flow system when the mask connector contains a flow restrictor, what color is the pilots mask?

Page 12: Environmental Systems

Oxygen Systems

• In a continuous-flow system when the mask connector contains a flow restrictor, what color is the pilots mask?

• Red

Page 13: Environmental Systems

Oxygen Systems• To what altitudes are the

following oxygen systems usable

• Continuous-flow

Page 14: Environmental Systems

Oxygen Systems

• Continuous-flow 25,000

• Diluter-demand

Page 15: Environmental Systems

Oxygen Systems

• Continuous-flow 25,000

• Diluter-demand 40,000

• Pressure-demand

Page 16: Environmental Systems

Oxygen Systems

• Continuous-flow 25,000

• Diluter-demand 40,000

• Pressure-demand above 40,000

Page 17: Environmental Systems

Oxygen Systems

• What kind do we have in the King Air?

• Pilots have Diluter demand

• Passengers have Constant flow.

Page 18: Environmental Systems

Oxygen Systems

• How can oxygen be stored?

Page 19: Environmental Systems

Oxygen Systems

• Cylinders or Chemical Oxygen Generators

Page 20: Environmental Systems

Oxygen Systems

• Where do we get oxygen to refill cylinders?

• Look in the Airport Facility Directory. Ensure you use aviation oxygen.

Page 21: Environmental Systems

Oxygen Systems

• What color are most high pressure oxygen cylinders painted?

• Green

Page 22: Environmental Systems

Oxygen Systems

• What is the lowest pressure to which an oxygen bottle should be depleted?

• Why?

Page 23: Environmental Systems

Oxygen Systems• What is the lowest pressure to

which an oxygen bottle should be depleted? 50 psi

• Why?

• To prevent moisture from entering the cylinder

Page 24: Environmental Systems

Oxygen Systems

• How long will an 66 cu ft cylinder of oxygen last?

Page 25: Environmental Systems

Oxygen Systems

• How long will an 66 cu ft cylinder of oxygen last?

• Depends on the temperature, pressure in the bottle and the number of people using the bottle.

Page 26: Environmental Systems

Oxygen Systems

• What are the pilot oxygen requirement for Part 91 flying

Page 27: Environmental Systems

Oxygen Systems

• FAR 91.211 From 12,500 to 14,000 feet flight crew up to 30 minutes without.

• Over 14,000 minimum flight crew must be provided and use supplemental oxygen

Page 28: Environmental Systems

Oxygen Systems

• Over 15,000 each occupant must be provided supplemental oxygen.

Page 29: Environmental Systems

Oxygen Systems

• What are the pilot supplemental oxygen requirement for Part 135 flying?

Page 30: Environmental Systems

Oxygen Systems

• FAR 135.89 From 10,000 to 12,000 any part of the flight over 30 minutes in duration.

• Over 12,000 continuously

Page 31: Environmental Systems

Cabin Pressurization

• What training must you receive to act as PIC of an pressurized aircraft certified for operations above 25,000 feet.

Page 32: Environmental Systems

Cabin Pressurization

• FAR 61.31(g) (1) logged ground training and obtained an endorsement in the person’s logbook or training record.

• FAR 61.31(g) (2) endorsement for flight, simulator or FTD.

Page 33: Environmental Systems

Cabin Pressurization• Ground training

–High altitude aerodynamics and meteorology

–Respiration

–Effects, symptoms and causes of hypoxia

Page 34: Environmental Systems

Cabin Pressurization

–Duration of consciousness w/o suppl oxygen

–Effects of long usage of suppl oxygen

Page 35: Environmental Systems

Cabin Pressurization

–Causes and effects of gas expansion

–Preventive measures for eliminating gas expansion and high altitude sickness

Page 36: Environmental Systems

Cabin Pressurization

–Physical phenomena and incidents of decompression

–Any other physiological aspects of high-altitude flight

Page 37: Environmental Systems

Cabin Pressurization• Flight, Simulator or FTD Training

– Normal operations above 25,000 feet

– Proper emergency procedures for simulated rapid decompression without actually depressurizing the aircraft

– Emergency descent procedures

Page 38: Environmental Systems

Pressurization Components

• What component modulates between open and closed to allow the pressurization air to vent out of the cabin at a controlled rate.

Page 39: Environmental Systems

Pressurization Components

• What component modulates between open and closed to allow the pressurization air to vent out of the cabin at a controlled rate.

• Outflow Valve

Page 40: Environmental Systems

Pressurization Components

• If the outflow valve fails, will the pressure continue to rise until we have a rapid decompression?

Page 41: Environmental Systems

Pressurization Components

• If the outflow valve fails, will the pressure continue to rise until we have a rapid decompression?

• No, you can activate the safety/dump valve

Page 42: Environmental Systems

Pressurization Control

• What is meant by differential range?

Page 43: Environmental Systems

Pressurization Control

• What is meant by differential range?

• When the pressurization system is working to prevent the cabin differential pressure from exceeding maximum limits.

Page 44: Environmental Systems

Cabin Differential Pressure

• What is the typical cabin differential pressure for general aviation aircraft?

• 3.35 to 4.5 P.S.I.D

• For large transport category aircraft

• 9.0 P.S.I.D

Page 45: Environmental Systems

Pressurization Control

• What is meant by isobaric range?

Page 46: Environmental Systems

Pressurization Control

• What is meant by isobaric range?

• When the system is working to maintain the cabin pressure altitude at the preset level.

Page 47: Environmental Systems

Cabin Pressure Controller

• What three items do you normally set in the cabin pressure control system?

Page 48: Environmental Systems

Cabin Pressure Controller• What three items do you normally

set in the cabin pressure control system?

• Cruise Altitude

• Cabin Altitude Selected

• Rate control knob

Page 49: Environmental Systems

Instrumentation

• Name three instruments used in conjunction with the pressure controller.

Page 50: Environmental Systems

Instrumentation• Name three instruments used in

conjunction with the pressure controller.

• Cabin Differential Pressure Gage

• Cabin Altimeter

• Cabin rate-of-climb instrument

Page 51: Environmental Systems

Pressurization Control

• When operating in the isobaric range, what will happen if you make a sudden change in the cabin altitude selected?

Page 52: Environmental Systems

Pressurization Control

• Extreme changes in cabin pressure causing significant pain to you and your passengers

Page 53: Environmental Systems

Pressurized Air

• In most light pressurized aircraft the pressurized air comes from the turbocharger’s compressor. What must be done to it before it is usable?

Page 54: Environmental Systems

Pressurized Air

• In most light pressurized aircraft the pressurized air comes from the turbocharger’s compressor. What must be done to it before it is usable?

• It must be cooled in a heat exchanger.

Page 55: Environmental Systems

Emergencies

• What are the most likely causes of rapid and explosive decompressions?

Page 56: Environmental Systems

Emergencies

• What are the most likely causes of rapid and explosive decompressions?

• Failure of the Windshield, cabin window or door.

Page 57: Environmental Systems

Minimum Oxygen

• What is the minimum oxygen supply for flying in a pressurized cabin above FL 250?

Page 58: Environmental Systems

Minimum Oxygen

• What is the minimum oxygen supply for flying in a pressurized cabin above FL 250?

• 10 minutes

Page 59: Environmental Systems

Oxygen Masks

• What oxygen mask requirements exist for flying above FL350.

Page 60: Environmental Systems

Oxygen Masks

• Generally, one pilot at the controls must wear and use an oxygen mask that is secured and sealed.

Page 61: Environmental Systems

Oxygen Masks

• An exception exists below FL 410 if both pilots have quick donning type masks that can be placed on the face with one hand and secured, sealed and operating within 5 sec.

Page 62: Environmental Systems

Hypoxia

• Name four types of hypoxia and describe them.

Page 63: Environmental Systems

Hypoxia

• Name four types of hypoxia and describe them.

• Hypoxic - altitude hypoxia caused by insufficient partial pressure of oxygen.

Page 64: Environmental Systems

Hypoxia

• Histotoxic - Alcohol and drug use, cannot be corrected by supplemental oxygen because the uptake of oxygen is impaired at the tissue level

Page 65: Environmental Systems

Hypoxia

• Hypemic - reduction of the oxygen-carrying capacity of the blood as a result of anemia, carbon monoxide poisoning, or excessive smoking.

Page 66: Environmental Systems

Hypoxia

• Stagnant hypoxia - poor circulation of the blood because of failure of the circulatory system to pump blood. It can be caused by pressure breathing or excessive G-forces.

Page 67: Environmental Systems

Prolonged Oxygen Use

• What are the symptoms of prolonged use of 100% oxygen?

Page 68: Environmental Systems

Prolonged Oxygen Use

• Bronchial cough, fever, vomiting nervousness, irregular heart beat and lowered energy.

Page 69: Environmental Systems

Vision

• What effect does altitude have on vision?

Page 70: Environmental Systems

Vision• Deteriorate with altitude

• Empty visual field caused by cloudless blue skies cause inaccuracies in judging speed, size and distance

• Sunglasses recommended to minimize the intensity of the sun’s ultraviolet rays.

Page 71: Environmental Systems

Decompression Sickness

• What are three types of evolved gas decompression sickness.

Page 72: Environmental Systems

Decompression Sickness

• Bends - pain in and around the joints

• Chokes - Chest pain and burning sensation, a sensation of suffocation.

• Paresthesia - tingling, itching, red rash, and warm and cold sensations

Page 73: Environmental Systems

Anti-icing

De-icing

Page 74: Environmental Systems

Anti Icing

• When do you want to turn on Anti Icing equipment?

Page 75: Environmental Systems

Anti Icing

• When do you want to turn on Anti Icing equipment?

• Prior to encountering ice conditions?

Page 76: Environmental Systems

Airfoil Ice Control

• De-icing Boots

• Thermal Anti-ice Systems

• Weeping Wing

Page 77: Environmental Systems

Windshield Ice Control

• Alcohol

• Thermal

Page 78: Environmental Systems

Windshield Ice Control

• What can happen if thermal anti ice is used on the ground?

Page 79: Environmental Systems

Windshield Ice Control• What can happen if thermal anti

ice is used on the ground?

• Bubbles can develop between the layers of window lamination resulting in the windshield having to be replaced.

Page 80: Environmental Systems

Propeller Ice Control

• Thermal

• Alcohol

Page 81: Environmental Systems

Other Ice Systems

• Pitot Heat

• Static Port

• Fuel Vent

• Stall Warning Sensors

Page 82: Environmental Systems

Ice

• What two conditions are necessary for structural ice to form?

Page 83: Environmental Systems

Ice

• Visible water such as rain or clouds

• Temperature where the moisture strikes the aircraft must be 0 or colder

Page 84: Environmental Systems

Ice

• What are the three kinds of ice?

Page 85: Environmental Systems

Ice

• What are the three kinds of ice?

• Clear, Rime and Mixed

• Which is the most dangerous kind of ice?

Page 86: Environmental Systems

Ice

• Which is the most dangerous kind of ice?

• Clear. It is very heavy and difficult to remove.

Page 87: Environmental Systems

Ice

• What kind of ice usually forms on aircraft flying through stratus type clouds?

Page 88: Environmental Systems

Ice

• What kind of ice usually forms on aircraft flying through stratus type clouds?

• Rime

Page 89: Environmental Systems

Ice

• What do ice pellets normally mean?

Page 90: Environmental Systems

Ice

• What do ice pellets normally mean?

• Freezing rain at higher altitudes

Page 91: Environmental Systems

Ice

• What type of cloud is hail normally associated?

Page 92: Environmental Systems

Ice

• What type of cloud is hail normally associated?

• Cumulonimbus

Page 93: Environmental Systems

Ice

• Frost does not change the basic aerodynamic shape of the wing so how does it affect the flow of air over the wing?

Page 94: Environmental Systems

Ice

• Roughness spoils the smooth flow of air causing early flow separation

Page 95: Environmental Systems

Ice

• What effect does frost have on stall speed?

Page 96: Environmental Systems

Ice

• What effect does frost have on stall speed?

• It normally increases stall speed between 5 and 10 per cent

Page 97: Environmental Systems

Ice

• If you begin to accumulate ice and you anticipate there is a warm front aloft, should you try to climb?

Page 98: Environmental Systems

Ice

• Depends on the situation, but the decision to either turn back or climb should be made quickly before too much ice accumulates which would preclude a climb.

Page 99: Environmental Systems

Ice

• If you accumulate ice, what precaution should you take on landing?

Page 100: Environmental Systems

Ice

• Avoid abrupt maneuvers because the aircraft has lost some aerodynamic efficiency, land with power at a higher than normal airspeed, be cautious about the use of flaps.

Page 101: Environmental Systems

Ice

• How can the NWS observe actual icing conditions?

Page 102: Environmental Systems

Ice

• They cannot. They can identify regions where icing is possible but they need PIREPS to know for sure.

Page 103: Environmental Systems

Ice

• When you preheat an aircraft, to what items should you pay attention?

Page 104: Environmental Systems

Ice• Oil, battery and instruments.

You should preheat not only the engine compartment but also the cockpit. Except at KSU-S, because we have had damage to aircraft interiors