Top Banner
283

Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

Jun 28, 2018

Download

Documents

trinhdien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit
Page 2: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

Enter/Exit Programming Mode

(This barcode is also found at back cover page.)

Framed values are default values.

Page 3: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

IMPORTANT NOTICE No warranty of any kind is made in regard to this material, including, but not limited to, implied warranties of merchantability or fitness for any particular purpose. We are not liable for any errors contained herein nor for incidental or consequential damages in connection with furnishing, performance or use of this material. We shall be under no liability in respect of any defect arising from fair wear and tear, willful damage, negligence, abnormal working conditions, failure to follow the instructions and warnings, or misuse or alteration or repair of the products without written approval. No part of this document may be reproduced, transmitted, stored in a retrieval system, transcribed, or translated into any human or computer or other language in any form or by any means electronic, mechanical, magnetic, optical, chemical, biologi- cal, manual or otherwise, except for brief passages which may be quoted for purposes of scholastic or literary review, without express written consent and authorization. We reserve the right to make changes in product design without reservation and without notification. The material in this guide is for information only and is subject to change without notice. All trademarks mentioned herein, registered or otherwise, are the properties of their owners. Specification or version may be subject to change without notice. The actual specification and version are based on the product delivered. General handling precautions • Do not dispose of the scanner in fire. • Do not put the scanner directly in the sun or by any heat source. • Do not use or store the scanner in a very humid place. • Do not drop the scanner or allow it to collide violently with other objects. • Do not take the scanner apart without authorization. Copyright © 2008. All rights reserved. Printed In May, 2008

Page 4: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

Radio Notice Some equipment generates uses and can radiate radio frequency energy. If not installed and used in accordance with the instructions in this manual, it may cause interference to radio communications. The equipment has been tested and found to comply with the limits for a Class A computing device pursuant to EN55022 and 47 CFR, Part 2 and Part 15 of the FCC rules. These specifications are designed to provide reasonable protection against interference when operated in a commercial environment. Radio and Television Interference Operation of this equipment in a residential area can cause interference to radio or television reception. This can be determined by turning the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures: Reorient the receiving antenna. Relocate the device with respect to the receiver. Move the device away from the receiver. Plug the device into a different outlet so that the device and the receiver are on different branch circuits. f necessary the user may consult the manufacturer, and authorized dealer, or experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful: “How to Identify and Resolve Radio-TV Interference Problems.” This booklet is available from the U.S. Government Printing Office, Washington, DC 20402 U.S.A., Stock No. 004000003454. For CE-countries This scanner is in conformity with CE standards. Please note that an approved, CE-marked power supply unit should be used in order to maintain CE conformance.

Page 5: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

Laser Safety The laser scanner complies with safety standard IEC 60825-1 for a Class I laser produce. It also complies with CDRH as applicable to a Class IIa laser product. Avoid long term staring into direct laser light. Radiant Energy: The laser scanner uses one low-power visible laser diodes operating at 650nm in an opto-mechanical scanner resulting in less than 3.9μW radiated power as observed through a 7mm aperture and averaged over 10 seconds. Do not attempt to remove the protective housing of the scanner, as un-scanned laser light with a peak output up to 0.8mW would be accessible inside. Laser Light Viewing: The scan window is the only aperture through which laser light may be observed from this product. A failure of the scanner motor, while the laser diode continues to emit a laser beam, may cause emission levels to exceed those for safe operation. The scanner has safeguards to prevent this occurrence. If, however, a stationary laser beam is emitted, the failing scanner should be disconnected from its power source immediately. Adjustments: Do not attempt any adjustments or alteration of this product. Do not remove the protective housing of the scanner. There are no user-serviceable parts inside. Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Optical: The use of optical instruments with this product will increase the eye hazard. Optical instruments include binoculars, magnifying glasses, and microscopes but do not include normal eye glasses worn by the user.

Page 6: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

TABLE OF CONTENTS Introduction.................................................................................................... 1 Changing the scanner setting........................................................................ 2 Default parameters........................................................................................ 2 Default values of operating parameters................................................ 2 Default values of keyboard emulation parameters setting…. ............... 3 Default values of RS-232C serial communication parameters ............. 3 Default values of USB emulation parameters....................................... 3 Default values of wand emulation parameters...................................... 3 Default values of decoding parameters ................................................ 4 Program procedure using barcode menus ........................................... 5 System setting............................................................................................... 6 Return to factory default ....................................................................... 7 Display firmware version ...................................................................... 7 Abort..................................................................................................... 8 Return to PC/AT default........................................................................ 8 Return to RS-232 default...................................................................... 9 Return to USB default........................................................................... 9 Return to wand emulation default ....................................................... 10 Return as customer default ................................................................ 10 Save as customer default ....................................................................11 Sleep timeout selection ............................................................................... 12 Same code delay time................................................................................. 20 Beeper sound selection............................................................................... 27 Barcode identifier code setting .................................................................... 38 Barcode identifier code selection........................................................ 39 Set message format with code identifier............................................. 40 Enable identifier code table as AIM standard ..................................... 40 Barcode identifier code setting ........................................................... 41 Message delay ............................................................................................ 47 Character delay ........................................................................................... 50 Interface communication setting.................................................................. 54 RS-232C interface configuration ........................................................ 55 Baud rate setting ......................................................................... 55 Data bit setting ............................................................................ 59 Stop bit setting............................................................................. 60 Parity bit setting........................................................................... 61 Handshaking protocol.................................................................. 64 ACK/NAK response time setting ................................................. 67 Message terminator for RS-232C................................................ 73 Keyboard wedge interface configuration ............................................ 77 Message terminator for keyboard wedge .................................... 77 Keyboard language selection ...................................................... 79 Capital lock setting ...................................................................... 85 Function key emulation ............................................................... 86

Page 7: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

USB interface configuration................................................................ 87 Keyboard type ............................................................................. 87 Message terminator for USB ....................................................... 88 Wand emulation configuration ............................................................ 90 Emulation speed selection .......................................................... 90 Emulation data output selection .................................................. 92 Emulation data idle state ............................................................. 94 Data editing ................................................................................................. 95 Header and trailer............................................................................... 96 Truncate header / trailer character ..................................................... 98 Add code length ............................................................................... 100 Symbology configuration ........................................................................... 101 Reading code selection .................................................................... 102 UPC / EAN parameters setting..........................................................113 Format........................................................................................113 Force UPC-E to UPC-A format...................................................118 Force UPC-A to EAN-13 format .................................................119 Force EAN-8 to EAN-13 format................................................. 120 Transmit UPC-A check digit....................................................... 122 Transmit UPC-E leading character............................................ 123 Transmit UPC-E check digit ...................................................... 124 Transmit EAN-8 check digit ....................................................... 125 Transmit EAN-13 check digit ..................................................... 126 Transmit UPC-A leading character ............................................ 127 Addendum................................................................................. 128 Add on format............................................................................ 130 Data Redundant check.............................................................. 140 Code 39 parameters setting ............................................................. 155 Code 39 reading length setting ................................................. 159 Data redundant check ............................................................... 163 Codabar parameters setting ............................................................. 165 Format....................................................................................... 165 Codabar reading length setting ................................................. 167 Codabar concatenation ............................................................. 169 Check digit ................................................................................ 170 Data redundant check ............................................................... 172 Code 128 parameters setting ........................................................... 174 Check digit ................................................................................ 174 Code 128 FNC2 concatenation ................................................. 176 Code 128 reading length setting ............................................... 177 EAN-128 FNC1 character ......................................................... 179 Data redundant check ............................................................... 180 ITF 2 of 5 parameters setting ........................................................... 182 Check digit ................................................................................ 182 ITF 2 of 5 reading length setting................................................ 184 Data redundant check ............................................................... 187

Page 8: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

Chinese postcode parameters setting .............................................. 189 Chinese postcode reading length setting .................................. 189 Data redundant check ............................................................... 191 MSI/PLESSY code parameters setting............................................. 193 Double check digit ..................................................................... 193 Single check digit ...................................................................... 195 MSI/PLESSY code reading length setting ................................. 196 Data redundant check ............................................................... 198 Code 93 parameters setting ............................................................. 200 Check digit ................................................................................ 201 Code 93 code reading length setting......................................... 202 Data redundant check ............................................................... 204 Full ASCII code table................................................................................. 206 Appendixes................................................................................................ 271 Appendix A ....................................................................................... 272 Appendix B ....................................................................................... 274

Page 9: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

1 ADVANCED PROGRAMMING GUIDE

1. INTRODUCTION This is a advanced programming guide for varies omnidirectional laser scanners, this guide contains a series of programming barcode labels, and by scanning these codes, it can make configurations to the scanners. This allows decoding options and interface protocols to be tailored to a specific application. The configuration is stored in non-volatile memory and will not be lost by removing power from the scanner.. Other than specified in this guide, for any special functions or specifications, please contact your dealer for details. The scanner must be properly powered before programming. For RS-232C type scanners, an external power adapter must be used to supply DC power to the scanner. If a keyboard emulation type scanner is used with an IBM PC/XT/AT, PS/2 or any fully compatible computers, power will be drawn from the keyboard port, therefore no external power adapter is required. If keyboard emulation type scanner is used with any other non IBM PC compatible computers, an external power adapter may be required.

Under the programming mode, the laser scanner will acknowledge a good and valid reading with a short beep. It will give long beeps for either an invalid or bad reading.

Page 10: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

2 ADVANCED PROGRAMMING GUIDE

2. CHANGE THE SCANNER SETTING In order to change the scanner setting, please follow the steps below: 1. Scan the “Enter/Exit Programming Mode” barcode, there will be 2 beeps

(low-high) indicating ready to make settings. 2. Scan barcodes for the desired feature (1 beep) 3. Scan the “Enter/Exit Programming Mode” barcode again to save the

configuration, there will be 2 beeps (long---short) indicating settings successfully.

After reading a valid barcode in programming mode the scanner will gave a high beep. 3. DEFAULT PARAMETERS This table gives the default settings of all the programmable parameters. The default settings will be restored whenever the "Reset" programming label is scanned and the laser scanner is in programming.

Default Values of Operating Parameters

Function Default Sleep mode

Motor sleep mode After 30 minutes Laser sleep mode After 10 minutes

Scanner timing Same code delay 200msec

Beeper Tone Frequency medium Duration 50msec

Code Identifiers Code ID off Code 39 M ITF 2 of 5 I Chinese post code H UPC-A A UPC-E E EAN-13 F EAN-8 FF Codabar N Code 128 K Code 93 L MSI/Plessy P

Page 11: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

3 ADVANCED PROGRAMMING GUIDE

Default Values of Keyboard Emulation Parameters Function Default Values

Keyboard type selection IBM PC/AT USA Message terminator Enter/ carriage return

Default Values of Serial Communication Parameters Function Default Values

Handshaking protocol None ACK/NAK response time setting 300 msec Baud rate 9600 Data bit 8 Stop bit 1 Parity None Message terminator selection CR/LF

Default Values of USB Emulation Parameters Function Default Values

Keyboard Type US Keyboard Message Terminator Enter

Default Values of Wand Emulation Parameters Function Default Values

Wand emulation speed Normal Wand emulation output Black = High Data output format Transmit as scan

Page 12: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

4 ADVANCED PROGRAMMING GUIDE

Default Values of Decoding Parameters

Function Code Default Value Code 39 Enable ITF 2 of 5 Disable Chinese Post Code Disable UPC/EAN/JAN Enable Codabar Disable MSI/PLESSY Disable Code 128 Disable Code 93 Disable EAN-128 Disable Italian Pharmacy Disable

Reading codes selection

ISSN/ ISBN Disable Codes Standard Start/stop characters Not transmitting Check digit Disabled Concatenation Off

Code 39

Length 3~32 Length 6-32 Interleaved

2 of 5 Check digit Disable Length 10~32 Chinese Post

Code Check digit Disable Format All Addendum Disable UPC-E=UPC-A Disabled UPC-A leading digit Transmit UPC-A check digit Transmit UPC-E leading digit Transmit

UPC/EAN /JAN

UPC-E check digit Transmit Type Standard Start/stop characters A,B,C,D Codabar Length 6~32 digits FNC 2 append Disable Code 128 Check digit Disable Length 3~32 Code 93 Check digit Not transmit Length 6~32 MSI Check digit Transmit

Italian Pharmacy Transmit "A" Character Not transmitting

Page 13: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

5 ADVANCED PROGRAMMING GUIDE

PROGRAM PROCEDURE USING BARCODE MENUS

Read Enter/Exit programming mode barcode to start of configuration

Change scanner setting by scanning mode

Select code 39 full ASCII table?

Read “Set”barcode to confirm

Read Enter/Exit programming mode barcode to save and exit

Yes

No

Page 14: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

6 ADVANCED PROGRAMMING GUIDE

System Setting

The series scanner is a multi-interface communication scanner. If you had ordered only the one type of interface, the device is configured in the interface

requested, i.e. RS-232C, keyboard wedge, wand emulation or USB. If not requested, the default interface is set in keyboard wedge interface (PC/AT);

using this section to change interfaces.

Page 15: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

7 ADVANCED PROGRAMMING GUIDE

Reset (Return of factory default) Reading of “Reset” barcode label turns all parameters back to default values, and the scanner remains in the last interface set when it is reset.

Reset (Return to factory default)

Display firmware version Reading of the “Display Firmware Version” will show the current firmware version on host.

Display Firmware Version

Page 16: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

8 ADVANCED PROGRAMMING GUIDE

Abort (Exit programming mode) Reading of the “Abort” barcode label discards all the parameters read prior to scan the “Enter/Exit of Programming Mode”.

Abort (Exit programming mode)

”.

Return to PC/AT default This barcode allows setting in keyboard wedge interface for IBM PC AT/PS/2 and compatibles.

Return to PC/AT default

Page 17: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

9 ADVANCED PROGRAMMING GUIDE

Return to RS-232 default The RS-232C interface scanner is often used when connecting to the serial port of a PC or terminal, reading the barcode to set the scanner into RS-232 interface.

Return to RS-232 default

Return to USB default Reading of “Return to USB default” sets the device into USB interface support.

Return to USB default

Page 18: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

10 ADVANCED PROGRAMMING GUIDE

Return to wand emulation default The Wand emulation is achieved by decoding a scanned barcode and then encoding it again, so that the output is readily decoded by an external decoder designed for processing of wand data.

Return to wand emulation default

Return as customer default Reading of the label sets the device back to customer saved parameter settings.

Return as customer default

.

Page 19: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

11 ADVANCED PROGRAMMING GUIDE

Save as customer default Reading of this label to save the desired parameters set into customer’s own default setting.

Save as customer default

How to save as customer default

Read Enter/Exit programming mode barcode to start of configuration

Change scanner setting by scanning mode

Read “save as customer default”

Read Enter/Exit programming mode barcode to save and exit

Page 20: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

12 ADVANCED PROGRAMMING GUIDE

Sleep Timeouts Selection

In the section, user can set both laser and/or motor to enter into sleep mode. The timeout programming labels will allow users to set the different time frame before entering into laser and/or motor sleep mode. The feature reduces power

consumption and prolongs scanner life time.

NOTE: Laser always enters sleep mode before motor.

If the motor timeout sets shorter than the motor Timeout, then laser enters sleep mode as motor enters sleep mode.

Page 21: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

13 ADVANCED PROGRAMMING GUIDE

Motor sleep mode off

Motor sleep time 5 min.

Page 22: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

14 ADVANCED PROGRAMMING GUIDE

Motor sleep time 10 min.

Motor sleep time 20 min.

Page 23: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

15 ADVANCED PROGRAMMING GUIDE

Motor sleep time 30 min.

Motor sleep time 60 min.

Page 24: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

16 ADVANCED PROGRAMMING GUIDE

Laser sleep mode off

Laser sleep time 5 min.

Page 25: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

17 ADVANCED PROGRAMMING GUIDE

Laser sleep time 10 min.

Laser sleep time 15 min.

Page 26: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

18 ADVANCED PROGRAMMING GUIDE

Laser sleep time 20 min.

Laser sleep time 25 min.

Page 27: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

19 ADVANCED PROGRAMMING GUIDE

Laser sleep time 30 min.

Page 28: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

20 ADVANCED PROGRAMMING GUIDE

Same Code Delay Time

This parameter sets the minimum time allowed between decodes of the same label.

Page 29: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

21 ADVANCED PROGRAMMING GUIDE

Same code delay time 50 msec.

Same code delay time 100 msec.

Page 30: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

22 ADVANCED PROGRAMMING GUIDE

Same code delay time 200 msec.

Same code delay time 300 msec.

Page 31: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

23 ADVANCED PROGRAMMING GUIDE

Same code delay time 400 msec.

Same code delay time 500 msec.

Page 32: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

24 ADVANCED PROGRAMMING GUIDE

Same code delay time 600 msec.

Same code delay time 700 msec.

Page 33: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

25 ADVANCED PROGRAMMING GUIDE

Same code delay time 800 msec.

Same code delay time 900 msec.

Page 34: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

26 ADVANCED PROGRAMMING GUIDE

Same code delay time 1000 msec.

Same code delay time infinite

Page 35: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

27 ADVANCED PROGRAMMING GUIDE

Beeper Sound Selection

This section includes all setting labels for beeper sound, settings includes tone frequency, volume, duration time, power on beep

enable/disable, and enable/disable sound when enter sleep mode. .

Page 36: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

28 ADVANCED PROGRAMMING GUIDE

Led/Beep after transmission

Led/Beep before transmission

Page 37: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

29 ADVANCED PROGRAMMING GUIDE

Power-up tone enable

Power-up tone disable

Page 38: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

30 ADVANCED PROGRAMMING GUIDE

Sleep sound

Sleep silent

Page 39: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

31 ADVANCED PROGRAMMING GUIDE

Medium beeper tone

Low beeper tone

Page 40: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

32 ADVANCED PROGRAMMING GUIDE

High beeper tone

Speaker disable

Page 41: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

33 ADVANCED PROGRAMMING GUIDE

Beeper sound duration (100msec)

Beeper sound duration (50msec)

Page 42: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

34 ADVANCED PROGRAMMING GUIDE

Beeper sound duration (20msec)

Beeper sound duration (5msec)

Page 43: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

35 ADVANCED PROGRAMMING GUIDE

Beeper sound duration 200msec

Beeper sound duration 500msec

Page 44: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

36 ADVANCED PROGRAMMING GUIDE

Loud beeper volume

Medium beeper volume

Page 45: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

37 ADVANCED PROGRAMMING GUIDE

Low beeper volume

Page 46: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

38 ADVANCED PROGRAMMING GUIDE

Barcode Identifier Code Setting

The scanner can transmit maximum 2 digits barcode identifier code for different type of barcodes. Using enable or disable identifier setting barcode to choose transmit or do not transmit barcode identifier code. The procedure is as follows: 1.) Scan “Enter/Exit Programming Mode” label 2.) Scan “Barcode Identifier Setting Code” label 3.) Scan the new code mark from ASCII table (maximum 2 digits). For example,

if “AB” is the code mark then scan “A” and “B” 4.) Scan “Save Setting to Confirm” label 5.) Scan “Enter/Exit Programming Mode” label

.

Page 47: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

39 ADVANCED PROGRAMMING GUIDE

Barcode Identifier Code Selection

Disable identifier code

Scan “Enable identifier code” label to transmit the label ID as shown in the table below.

Code 39 M ITF 2 of 5 I Chinese post code H UPC-A A UPC-E E EAN-13 F EAN-8 FF Codabar N Code 128 K Code 93 L MSI/Plessy P

Enable identifier code

Page 48: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

40 ADVANCED PROGRAMMING GUIDE

Set Message Format with Code Identifier

I S 0 2

Code Code identifier UPC-A A UPC-E E EAN-8 FF EAN-13 F CODE 39 * CODBAR % ITF 2 OF 5 i CODE 93 & CODE 128 # MSI/PLESSY @ EAN-128 P

Enable Identifier Code Table as AIM Standard

Page 49: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

41 ADVANCED PROGRAMMING GUIDE

Barcode Identifier Code Setting

Code 39 identifier code setting

ITF 2 of 5 identifier code setting

Page 50: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

42 ADVANCED PROGRAMMING GUIDE

Chinese Post code identifier code setting

UPC-E identifier code setting

Page 51: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

43 ADVANCED PROGRAMMING GUIDE

UPC-A identifier code setting

EAN-13 identifier code setting

Page 52: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

44 ADVANCED PROGRAMMING GUIDE

EAN-8 identifier code setting

Codabar identifier code setting

Page 53: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

45 ADVANCED PROGRAMMING GUIDE

Code 128 identifier code setting

Code 93 identifier code setting

Page 54: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

46 ADVANCED PROGRAMMING GUIDE

MSI identifier code setting

Save setting to confirm

Page 55: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

47 ADVANCED PROGRAMMING GUIDE

Message delay

In this section contains different delay time frame between two consecutive messages. This delay will be added before each date transmission.

Page 56: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

48 ADVANCED PROGRAMMING GUIDE

Inter message delay 0 ms

Inter message delay 100 ms

Page 57: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

49 ADVANCED PROGRAMMING GUIDE

Inter message delay 500 ms

Inter message delay 1000 ms

Page 58: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

50 ADVANCED PROGRAMMING GUIDE

Character delay

This option governs delay time between two consecutive characters; the delay time can be altered by scanning the following labels.

Page 59: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

51 ADVANCED PROGRAMMING GUIDE

Character delay 5 ms

Inter character delay 0 ms

Page 60: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

52 ADVANCED PROGRAMMING GUIDE

Inter character delay 10 ms

Inter character delay 20 ms

Page 61: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

53 ADVANCED PROGRAMMING GUIDE

Inter character delay 50 ms

Page 62: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

54 ADVANCED PROGRAMMING GUIDE

Interface Communication Setting

This section contains labels to configure the scanner to user’s host terminal. The following interfaces are supported:

*Keyboard wedge *RS-232C interface

*USB interface *Wand emulation

Page 63: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

55 ADVANCED PROGRAMMING GUIDE

RS-232C interface configuration

1. Baud Rate setting

Baud Rate 38400

Baud Rate 19200

Page 64: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

56 ADVANCED PROGRAMMING GUIDE

Baud Rate 9600

Baud Rate 4800

Page 65: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

57 ADVANCED PROGRAMMING GUIDE

Baud Rate 2400

Baud Rate 1200

Page 66: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

58 ADVANCED PROGRAMMING GUIDE

Baud Rate 57600

Baud Rate 115200

Page 67: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

59 ADVANCED PROGRAMMING GUIDE

2. Date Bit Setting 7 data bit

8 data bit

Page 68: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

60 ADVANCED PROGRAMMING GUIDE

3. Stop Bit Setting 1 Stop bit

2 Stop bit

Page 69: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

61 ADVANCED PROGRAMMING GUIDE

4. Parity Bit Setting Even Parity

Odd Parity

Page 70: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

62 ADVANCED PROGRAMMING GUIDE

Mark Parity

Space Parity

Page 71: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

63 ADVANCED PROGRAMMING GUIDE

None Parity

Page 72: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

64 ADVANCED PROGRAMMING GUIDE

5. Handshaking Protocol The RS-232C type scanner supports four handshaking protocols. With these options of communication protocol, users can tailor the scanner to meet the requirement of most systems. These handshaking protocols are: *None: The scanner will transmit any read data unconditionally. The scanner will not check the receiving device or the transmitted message. *RTS/CTS: Under this handshaking protocol, the scanner use the RTS pin to instruct the connected device to transmit data and test the CTS pin for readiness of the connected device to receive data. *ACK/NAK: While selecting this option, the scanner waits for an ACK or NAK signal from the host computer after each data transmission. Normally, the scanner will temporarily stored the scanned data in the memory buffer before receiving the ACK or NAK signal. If the ACK signal is received, it will clear the transmitted data and continue to send the next data. In case of the NAK signal is received, it will repeat to transmit the same data until receiving the ACK signal. *Xon/Xoff: During the data communication, if a scanner receives an Xoff (ASCII 013H), it will stop the transmission at once. The scanner waits for a Xon (ASCII 01H) to start the transmission again.

Page 73: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

65 ADVANCED PROGRAMMING GUIDE

None handshaking

ACK/NAK

Page 74: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

66 ADVANCED PROGRAMMING GUIDE

Xon/Xoff

RTS/CTS

Page 75: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

67 ADVANCED PROGRAMMING GUIDE

6. ACK/NAK Response Time Setting ACK/NAK response time 300ms

ACK/NAK response time 500ms

Page 76: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

68 ADVANCED PROGRAMMING GUIDE

ACK/NAK response time 1s

ACK/NAK response time 2s

Page 77: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

69 ADVANCED PROGRAMMING GUIDE

ACK/NAK response time 3s

ACK/NAK response time 5s

Page 78: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

70 ADVANCED PROGRAMMING GUIDE

ACK/NAK response time Infinity

Disable ACK/NAK timeout beeper

Page 79: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

71 ADVANCED PROGRAMMING GUIDE

Enable ACK/NAK timeout beeper

Enable beeper on<BEL> character

Page 80: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

72 ADVANCED PROGRAMMING GUIDE

Ignore beep on <BEL>character

Page 81: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

73 ADVANCED PROGRAMMING GUIDE

7. Message terminator for RS-232C The series RS-232C type scanner can be programmed to append a terminator to every message sent via the serial port. Different terminator will be appended at the end of message sent from the serial port.

RS-232 message terminator-none

RS-232 message terminator-CR/LF

Page 82: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

74 ADVANCED PROGRAMMING GUIDE

RS-232 message terminator-CR

RS-232 message terminator-LF

Page 83: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

75 ADVANCED PROGRAMMING GUIDE

RS-232 message terminator-H tab

RS-232 message terminator-STX/ETX

Page 84: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

76 ADVANCED PROGRAMMING GUIDE

RS-232 message terminator-EOT

Page 85: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

77 ADVANCED PROGRAMMING GUIDE

Keyboard wedge interface configuration 1. Message terminator for keyboard Wedge

Keyboard terminator---none

Keyboard terminator---Enter

Page 86: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

78 ADVANCED PROGRAMMING GUIDE

Keyboard terminator---H-TAB

Page 87: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

79 ADVANCED PROGRAMMING GUIDE

2. Keyboard Language Selection Enable International keyboard type

(Alt method)

Keyboard language support---USA

Page 88: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

80 ADVANCED PROGRAMMING GUIDE

Keyboard language support---Germany

Keyboard language support---UK

Page 89: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

81 ADVANCED PROGRAMMING GUIDE

Keyboard language support---French

Keyboard language support---Spanish

Page 90: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

82 ADVANCED PROGRAMMING GUIDE

Keyboard language support--- Italian

Keyboard language support--- Swiss

Page 91: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

83 ADVANCED PROGRAMMING GUIDE

Keyboard language support---Swedish

Keyboard language support---Japanese

Page 92: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

84 ADVANCED PROGRAMMING GUIDE

Keyboard language support---Belgium

Page 93: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

85 ADVANCED PROGRAMMING GUIDE

3. Capital Lock Select the suitable code to match your keyboard caps lock status

Capital lock on

Capital lock off

Page 94: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

86 ADVANCED PROGRAMMING GUIDE

4. Function Key Emulation In this section, user can emulate Function keys, Arrow keys, and many other “extended” keys. An IBM compatible keyboard does not translate to ASCII characters; it can be concatenated with input data as header and/or trailer. (see Appendix B)

Function key emulation enable

Function key emulation disable

Page 95: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

87 ADVANCED PROGRAMMING GUIDE

USB interface configuration The USB mode is effectively a keyboard emulator that works with hosts, such as USB-compatible operating system and USB ports. USB compatible operating systems are Windows 98, Windows NT 5.0 and later, no additional software is needed since the USB driver support its built-in operating system 1. Keyboard Type

Keyboard type---USA (Scan method)

Keyboard type. (ALT code method)

Page 96: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

88 ADVANCED PROGRAMMING GUIDE

2. Message terminator for USB None

Enter

Page 97: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

89 ADVANCED PROGRAMMING GUIDE

H tab

Page 98: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

90 ADVANCED PROGRAMMING GUIDE

Wand emulation configuration

1. Emulation Speed Selection The data output speed can be set to befit the external decoder.

Wand emulation speed=Low (1ms narrow element width)

Wand emulation speed =medium (600 us narrow element width)

Page 99: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

91 ADVANCED PROGRAMMING GUIDE

Wand emulation speed= high (300 us narrow element width)

Wand emulation speed ---- higher (100us narrow element width)

Page 100: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

92 ADVANCED PROGRAMMING GUIDE

2. Emulation Data Output Selection The decoded data output logic level can be set to befit the external decoder.

Wand emulation data output black = high

Wand emulation data output black = low

Page 101: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

93 ADVANCED PROGRAMMING GUIDE

Wand Data Transmitted as Scanning

Enable Wand output data format as Code 39

Page 102: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

94 ADVANCED PROGRAMMING GUIDE

3. Emulation data idle state selection The level refer to wand emulation data signal when not in use

Idle=high

Idle=low

Page 103: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

95 ADVANCED PROGRAMMING GUIDE

Data Editing

Page 104: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

96 ADVANCED PROGRAMMING GUIDE

HEADER AND TRAILER The Header and Trailer allows you to append a header and/or a trailer to every message transmitted via the serial ports, USB or the keyboard port. There is no restriction in selecting header or trailer characters as far as the sum of the lengths of header and trailer is not greater than 10 digits. 1. Select either header or trailer you are going to program by scanning the

corresponding label 2. Scan the character(s) you want from the enclosed ASCII table to set as

header or trailer (be sure to enable full ASCII code 39 option before you start). 3. Read the “save setting to confirm” label to confirm your choice into memory.

Header (Preamble)

Page 105: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

97 ADVANCED PROGRAMMING GUIDE

Trailer (Postamble)

Save setting to confirm

Page 106: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

98 ADVANCED PROGRAMMING GUIDE

Truncate Header/Trailer Character This setting allows you to truncate a number of header or trailer for symbology. When you do, the specific character you select is deleted from the symbology you want. 1.) Scan the ”Enter/Exit programming mode” label. 2.) Select the ”Truncate header or truncate trailer” label. 3.) Scan two barcode value from the full ASCII code table(0~9). For example,

if 2 number of header that you want to clear, then scan ”0” and “2. 4,) Scan ”save setting to confirm” label 5,) Scan “Enter/Exit programming mode” label to end of configuration.

Page 107: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

99 ADVANCED PROGRAMMING GUIDE

Truncate header character

Truncate trailer character

Page 108: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

100 ADVANCED PROGRAMMING GUIDE

Add Code Length This option allows you to add the reading barcode numeric characters as header

Add code length as header enable (all barcode)

Add code length as header disable (all barcode)

Page 109: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

101 ADVANCED PROGRAMMING GUIDE

Symbology Configuration

In this section, device can be programmed to recognize one or more barcode symbologies automatically. If the scanner is configured to support multiple barcode symbologies, the scanner will discriminate different symbologies automatically, however, to improve scanning performance, you should enable only those symbologies that will be in active use.

Page 110: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

102 ADVANCED PROGRAMMING GUIDE

Reading code selection

Code 39 enable

Code 39 disable

Page 111: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

103 ADVANCED PROGRAMMING GUIDE

Codabar enable

Codabar disable

Page 112: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

104 ADVANCED PROGRAMMING GUIDE

UPC/EAN/JAN enable

UPC/EAN/JAN disable (only can’t transmitted but can decode)

Page 113: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

105 ADVANCED PROGRAMMING GUIDE

ITF 2 of 5 enable

ITF 2 of 5 disable

Page 114: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

106 ADVANCED PROGRAMMING GUIDE

Chinese postcode enable

Chinese postcode disable

Page 115: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

107 ADVANCED PROGRAMMING GUIDE

Code 128 enable

Code 128 disable

Page 116: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

108 ADVANCED PROGRAMMING GUIDE

Code 93 enable

Code 93 disable

Page 117: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

109 ADVANCED PROGRAMMING GUIDE

EAN-128 enable

EAN-128 disable

Page 118: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

110 ADVANCED PROGRAMMING GUIDE

EAN convert to ISSN/ISBN

EAN convert to ISSN/ISBN disable

Page 119: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

111 ADVANCED PROGRAMMING GUIDE

Code 32 enable

Code 32 disable

Page 120: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

112 ADVANCED PROGRAMMING GUIDE

MSI enable

MSI disable

Page 121: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

113 ADVANCED PROGRAMMING GUIDE

UPC/EAN Parameters setting In this section, device can be programmed to recognize some or all derivatives of UPC/EAN. These derivatives are UPC-A, UPC-E, EAN-8, and EAN-13. Either 2 of 5 addendum digits are supported addendum digits are those additional digits after normal stop character. The programming menu for UPC/EAN/JAN also provides several options to govern the transmission of scanned data. *UPC/EAN expansion *Check digit transmission *Data redundant check *Addendum seek timeout *Addendum left/right margin adjust

1. Format

UPC/EAN/JAN all enable

Page 122: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

114 ADVANCED PROGRAMMING GUIDE

EAN-8 or EAN-13 enable

UPC-A and EAN-13 Enable

Page 123: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

115 ADVANCED PROGRAMMING GUIDE

UPC-A and UPC-E Enable

UPC-A enable

Page 124: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

116 ADVANCED PROGRAMMING GUIDE

UPC-E enable

EAN-13 enable

Page 125: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

117 ADVANCED PROGRAMMING GUIDE

EAN-8 enable

Page 126: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

118 ADVANCED PROGRAMMING GUIDE

2. Force UPC-E to UPC-A format

Force UPC-E to UPC-A format enable

Force UPC-E to UPC-A format disable

Page 127: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

119 ADVANCED PROGRAMMING GUIDE

3. Force UPC-A to EAN-13 format

Force UPC-A to EAN-13 format enable

Force UPC-A to EAN-13 format disable

Page 128: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

120 ADVANCED PROGRAMMING GUIDE

4. Force EAN-8 to EAN-13 format

Force EAN-8 to EAN-13 format disable

Force EAN-8 to EAN-13 format enable

Page 129: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

121 ADVANCED PROGRAMMING GUIDE

EAN-13 first “0” can transmitted

EAN-13 first “0” can’t transmitted

Page 130: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

122 ADVANCED PROGRAMMING GUIDE

5. Transmit UPC-A check digit

Transmit UPC-A check digit enable

Transmit UPC-A check digit disable

Page 131: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

123 ADVANCED PROGRAMMING GUIDE

6. Transmit UPC-E leading character

Transmit UPC-E leading character enable

Transmit UPC-E leading character disable

Page 132: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

124 ADVANCED PROGRAMMING GUIDE

7. Transmit UPC-E check digit

Transmit UPC-E check digit enable

Transmit UPC-E check digit disable

Page 133: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

125 ADVANCED PROGRAMMING GUIDE

8. Transmit EAN-8 check digit

Transmit EAN-8 check digit enable

Transmit EAN-8 check digit disable

Page 134: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

126 ADVANCED PROGRAMMING GUIDE

9. Transmit EAN-13 check digit

Transmit EAN-13 check digit enable

Transmit EAN-13 check digit disable

Page 135: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

127 ADVANCED PROGRAMMING GUIDE

10. Transmit UPC-A leading character

Transmit UPC-A leading character enable

Transmit UPC-a leading character disable

Page 136: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

128 ADVANCED PROGRAMMING GUIDE

11. Addendum

UPC/EAN add on off

Add on 5 only

Page 137: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

129 ADVANCED PROGRAMMING GUIDE

Add on 2 only

Add on 2 or 5

Page 138: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

130 ADVANCED PROGRAMMING GUIDE

12. Add on format

Add on format with separator

Add on format without separator

Page 139: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

131 ADVANCED PROGRAMMING GUIDE

EAN/UPC +Add on (none mandatory)

EAN/UPC + Add on(mandatory)

Page 140: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

132 ADVANCED PROGRAMMING GUIDE

EAN/UPC + add on mandatory for 378/379 French Supplement requirement not sent for other

EAN/UPC +add on mandatory for 978/977 book land Supplement requirements

Not sent for other

Page 141: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

133 ADVANCED PROGRAMMING GUIDE

EAN/UPC + addon mandatory for 434/439

German Supplement requirement Not sent for other

EAN/UPC + add on mandatory for 419/414 Euro amounts Supplement requirement

not sent for other

Page 142: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

134 ADVANCED PROGRAMMING GUIDE

EAN/UPC + add on mandatory for 378/379

French Supplement requirement optionally for other

EAN/UPC + add on mandatory for 978/977 Book land Supplement requirement

optionally for other

Page 143: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

135 ADVANCED PROGRAMMING GUIDE

EAN/UPC + add on mandatory for 434/439

German Supplement requirement optionally for other

EAN/UPC + add on mandatory for 419/414 Euro amounts Supplement requirement

optionally for other

Page 144: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

136 ADVANCED PROGRAMMING GUIDE

EAN/UPC + add on mandatory for 491 Japanese (bookland) Supplement requirement optionally for other

EAN/UPC + add on mandatory for 491 Japanese (bookland) Supplement

requirement Not sent for other

Page 145: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

137 ADVANCED PROGRAMMING GUIDE

Double code not allowed

Double code mandatory for 978/192

Page 146: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

138 ADVANCED PROGRAMMING GUIDE

Double code format without separator

Double code format with separator

Page 147: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

139 ADVANCED PROGRAMMING GUIDE

Double code format with free (one character)

Page 148: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

140 ADVANCED PROGRAMMING GUIDE

13. Data Redundant Check In this section, user can set decoder data redundant check, before it is accepted as a good read. A higher data redundant check read setting offers more assurance that a barcode has been read correctly, while a lower setting allows faster scanning performance.

UPC-A Data Redundant Check

UPC-A data redundant check = 0

UPC-A data redundant check = 1

Page 149: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

141 ADVANCED PROGRAMMING GUIDE

UPC-A data redundant check = 2

UPC-A data redundant check = 3

Page 150: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

142 ADVANCED PROGRAMMING GUIDE

UPC-E Data Redundant Check

UPC-E data redundant check = 0

UPC-E data redundant check = 1

Page 151: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

143 ADVANCED PROGRAMMING GUIDE

UPC-E data redundant check = 2

UPC-E data redundant check = 3

Page 152: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

144 ADVANCED PROGRAMMING GUIDE

EAN-13 Data Redundant Check

EAN-13 data redundant check = 0

EAN- 13 data redundant check = 1

Page 153: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

145 ADVANCED PROGRAMMING GUIDE

EAN-13 data redundant check = 2

EAN-13 data redundant check = 3

Page 154: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

146 ADVANCED PROGRAMMING GUIDE

EAN-8 Data Redundant Check

EAN-8 data redundant check = 0

EAN-8 data redundant check = 1

Page 155: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

147 ADVANCED PROGRAMMING GUIDE

EAN-8 data redundant check =2

EAN-8 data redundant check = 3

Page 156: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

148 ADVANCED PROGRAMMING GUIDE

2 digit addendum data redundant check

2 digit addendum data redundant check = 0

2 digit addendum data redundant check = 1

Page 157: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

149 ADVANCED PROGRAMMING GUIDE

2 digit addendum data redundant check = 2

2 digit addendum data redundant check = 3

Page 158: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

150 ADVANCED PROGRAMMING GUIDE

5 digit addendum data redundant check

5 digit addendum data redundant check = 0

5 digit addendum data redundant check = 1

Page 159: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

151 ADVANCED PROGRAMMING GUIDE

5 digit addendum data redundant check =2

5 digit addendum data redundant check = 3

Page 160: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

152 ADVANCED PROGRAMMING GUIDE

Addendum seek timeout

Addendum seek timeout =6

Addendum seek timeout=7

Page 161: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

153 ADVANCED PROGRAMMING GUIDE

Addendum seek timeout=8

Addendum seek timeout=9

Page 162: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

154 ADVANCED PROGRAMMING GUIDE

Addendum seek timeout=10

Page 163: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

155 ADVANCED PROGRAMMING GUIDE

Code 39 parameters setting The scanner can program to support the standard code 39 or Full ASCII code 39. In addition, it is user’s option to transmit or not to transmit the start and stop characters. You can also enable or disable the check digit feature. If the check digit feature is enabled, you have the further option to decide whether the check digit is transmitted or not.

Character Set

Standard code 39

FULL ASCII code 39

Page 164: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

156 ADVANCED PROGRAMMING GUIDE

Start/Stop Character Transmission

Code 39 start/stop character transmission

Code 39 start/stop character without transmission

Page 165: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

157 ADVANCED PROGRAMMING GUIDE

Check Digit

Code 39 check digit calculate and transmit

Code 39 check digit calculate but without transmit

Page 166: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

158 ADVANCED PROGRAMMING GUIDE

No check character

Page 167: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

159 ADVANCED PROGRAMMING GUIDE

1. Code 39 reading length setting The default code 39 length is 3 ~32 character. It can be set at minimum 1 digit and maximum 62 digits.

CODE LENGTH SETTING FLOW

Code 39 maximum length setting

Programming Minimum or Maximum label

Scan two number label from Code39 FULL ASCII table.

Example:4 character length, scan “0”,”4”

Scan “Save setting to confirm” label to confirm your choice into

memory.

Page 168: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

160 ADVANCED PROGRAMMING GUIDE

Code 39 minimum length setting

Save setting to confirm

Page 169: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

161 ADVANCED PROGRAMMING GUIDE

Concatenation

Code 39 concatenation enable

Code 39 concatenation disable

Page 170: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

162 ADVANCED PROGRAMMING GUIDE

Code 32 “A” Character Transmit

Code 32 (Italian pharmacy) transmit “A” character

Code 32(Italian pharmacy)without transmit “A” character

Page 171: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

163 ADVANCED PROGRAMMING GUIDE

2. Data Redundant Check In this section, users can use labels to set decoder data redundant check, before it is accepted as a good read. A higher data redundant check read setting offers more assurance that a barcode has been read correctly, while a lower setting allows faster scanning performance.

Code 39 data redundant check = 0

Code 39 data redundant check = 1

Page 172: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

164 ADVANCED PROGRAMMING GUIDE

Code 39 data redundant check = 2

Code 39 data redundant check = 3

Page 173: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

165 ADVANCED PROGRAMMING GUIDE

CODABAR Parameters Setting In this section, there are varies settings for Codabar symbology, including: • Check character verification or transmission • CODABAR concatenation • Data redundant check • Start/Stop Characters • Min./Max. length setting

1. Format

Codabar start/stop character transmission ----none

Codabar start/stop character transmission ---- A,B,C,D

Page 174: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

166 ADVANCED PROGRAMMING GUIDE

Codabar start/stop character transmission ---- DC1~DC4

Codabar start/stop character transmission ---- a/t,b/n,c/*,d/e

Page 175: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

167 ADVANCED PROGRAMMING GUIDE

2. CODABAR reading length setting The default CODABAR length is 6 ~32 character. It can be set at minimum 1 digit and maximum 62 digits

CODE LENGTH SETTING FLOW

Codabar maximum length setting

Programming Minimum or Maximum label

Scan two number label from Code39 FULL ASCII table.

Example:4 character length, scan “0”,”4”

Scan “save setting to confirm” label to confirm your choice into

memory.

Page 176: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

168 ADVANCED PROGRAMMING GUIDE

Codabar minimum length setting

Save setting to confirm

Page 177: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

169 ADVANCED PROGRAMMING GUIDE

3. Concatenation

Codabar concatenation disable

Codabar concatenation enable

Page 178: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

170 ADVANCED PROGRAMMING GUIDE

4. Check digit

No check character

Check digits calculate but not transmit

Page 179: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

171 ADVANCED PROGRAMMING GUIDE

Check digit calculate and transmit

Page 180: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

172 ADVANCED PROGRAMMING GUIDE

5. Data Redundant Check In this section, users can set decoder data redundant check, before it is accepted as a good read. A higher data redundant check read setting offers more assurance that a bar code has been read correctly, while a lower setting allows faster scanning performance.

Codabar data redundant check = 0

Codabar data redundant check = 1

Page 181: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

173 ADVANCED PROGRAMMING GUIDE

Codabar data redundant check = 2

Codabar data redundant check = 3

Page 182: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

174 ADVANCED PROGRAMMING GUIDE

Code 128 Parameters Setting In this section, there are varies setting for Code 128 symbology, including: • Check character verification or transmission • FNC2 concatenation • Data redundant check • FNC1 transmission for EAN-128 • Min./Max. length setting

1. Check Digit

No check character

Page 183: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

175 ADVANCED PROGRAMMING GUIDE

Calculate but not transmit

Calculate and transmit

Page 184: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

176 ADVANCED PROGRAMMING GUIDE

2. Code 128 FNC2 concatenation This function permits the temporary storage of a code in the decoder, if this code starts with FNC 2 character. The message buffered will be concatenated and transmitted with the next code having no FNC 2 character

Code 128 FNC2 concatenation enable

Code 128 FNC2 concatenation disable

Page 185: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

177 ADVANCED PROGRAMMING GUIDE

3. Code 128 reading length setting The default code 128 length is 3 ~62 character. It can be set at minimum 1 digit and maximum 62 digits

CODE LENGTH SETTING FLOW

Code 128 maximum length setting

Programming Minimum or Maximum label

Scan two number label from Code39 FULL ASCII table.

Example:4 character length, scan “0”,”4”

Scan “save setting to confirm” label to confirm your choice into

memory.

Page 186: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

178 ADVANCED PROGRAMMING GUIDE

Code 128 minimum length setting

Save setting to confirm

Page 187: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

179 ADVANCED PROGRAMMING GUIDE

4. EAN-128 FNC1 CHARACTER

EAN-128 FNC1 Character transmitted

EAN-128 FNC1 not character transmitted

Page 188: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

180 ADVANCED PROGRAMMING GUIDE

5. Data Redundant Check In this section, users can set decoder data redundant check, before it is accepted as a good read. A higher data redundant check read setting offers more assurance that a bar code has been read correctly, while a lower setting allows faster scanning performance

Code 128 data redundant check = 0

Code 128 data redundant check = 1

Page 189: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

181 ADVANCED PROGRAMMING GUIDE

Code 128 data redundant check = 2

Code 128 data redundant check = 3

Page 190: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

182 ADVANCED PROGRAMMING GUIDE

ITF 2 of 5 Parameters Setting In this section, there are varies ITF 2 of 5 symbology including: • Check character verification or transmission • Data redundant check • Two fixed length setting • Min./Max. length setting

1. Check Digit

ITF 2 of 5 no check character

Page 191: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

183 ADVANCED PROGRAMMING GUIDE

ITF 2 of 5 check digit calculate and transmit

ITF 2 of 5 check digit calculate but without transmit

Page 192: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

184 ADVANCED PROGRAMMING GUIDE

2. ITF 2 of 5 reading length setting The default ITF 2 of 5 length is 6 ~32 character. It can be set at minimum 2 digit and maximum 62 digits

Code length setting flow

ITF 2 of 5 code maximum length setting

Programming Minimum or Maximum label

Scan two number label from Code39 FULL ASCII table.

Example:4 character length, scan “0”,”4”

Scan “save setting to confirm” label to confirm your choice into

memory.

Page 193: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

185 ADVANCED PROGRAMMING GUIDE

ITF 2 of 5 code minimum length setting

Save setting to confirm

Page 194: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

186 ADVANCED PROGRAMMING GUIDE

ITF 2 of 5 one fixed length setting

ITF 2 of 5 two fixed length setting

Page 195: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

187 ADVANCED PROGRAMMING GUIDE

3. Data Redundant Check In this section, users can set decoder data redundant check, before it is accepted as a good read. A higher data redundant check read setting offers more assurance that a bar code has been read correctly, while a lower setting allows faster scanning performance

ITF 25 data redundant check =0

ITF 25 data redundant check = 1

Page 196: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

188 ADVANCED PROGRAMMING GUIDE

ITF 25 data redundant check = 2

ITF 25 data redundant check = 3

Page 197: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

189 ADVANCED PROGRAMMING GUIDE

Chinese post code parameters setting In this section, there are varies Chinese post code symbology including: • Data redundant check • Min./Max. length setting .

1. Chinese postcode reading length setting The default Chinese post code length is 10 ~32 character. It can be set at minimum 1 digit and maximum 62 digits. In order to avoid missing characters when scanning is incomplete, we recommend using a short-range length or fixed length to read.

Code length setting flow

Chinese post code maximum length setting

Programming Minimum or Maximum label

Scan two number label from Code39 FULL ASCII table.

Example:4 character length, scan “0”,”4”

Scan “save setting to confirm” label to confirm your choice into

memory.

Page 198: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

190 ADVANCED PROGRAMMING GUIDE

Chinese post code minimum length setting

Save setting to confirm

Page 199: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

191 ADVANCED PROGRAMMING GUIDE

2. Data Redundant Check

The option allows you to set decoder data redundant check, before it is accepted as a good read. A higher data redundant check read setting offers more assurance that a bar code has been read correctly, while a lower setting allows faster scanning performance

Chinese post code data redundant check = 0

Chinese post code data redundant check = 1

Page 200: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

192 ADVANCED PROGRAMMING GUIDE

Chinese post code data redundant check = 2

Chinese post code data redundant check = 3

Page 201: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

193 ADVANCED PROGRAMMING GUIDE

MSI/PLESSY code Parameters Setting In this section, there are varies set up for Chinese post code symbology, including: • Check character verification or transmission • Data redundant check • Min./Max. length setting

1. Double Check Digit

MSI/PLESSY double check digit calculate but not transmit

MSI/PLESSY double check digit without calculate and transmit

Page 202: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

194 ADVANCED PROGRAMMING GUIDE

MSI/PLESSY double check digit calculate but only first digit transmit

MSI/PLESSY double check digit calculate and both transmit

Page 203: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

195 ADVANCED PROGRAMMING GUIDE

2. Single Check Digit

MSI/PLESSY single check digit calculate but without transmit

MSI/Plessy single check digit calculate and transmit

Page 204: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

196 ADVANCED PROGRAMMING GUIDE

3. MSI/PLESSY code reading length setting The default MSI/PLESSY code length is 6~32 character. It can be set at minimum 1 digit and maximum 62 digits

Code Length Setting Flow

MSI/PLESSY maximum length setting

Programming Minimum or Maximum label

Scan two number label from Code39 FULL ASCII table.

Example:4 character length, scan “0”,”4”

Scan “save setting to confirm” label to confirm your choice into

memory.

Page 205: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

197 ADVANCED PROGRAMMING GUIDE

MSI/PLESSY minimum length setting

Save setting to confirm

Page 206: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

198 ADVANCED PROGRAMMING GUIDE

4. Data Redundant Check The option allows you to set decoder data redundant check, before it is accepted as a good read. A higher data redundant check read setting offers more assurance that a barcode has been read correctly, while a lower setting allows faster scanning performance

MSI data redundant check = 0

MSI data redundant check = 1

Page 207: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

199 ADVANCED PROGRAMMING GUIDE

MSI data redundant check = 2

MSI data redundant check = 3

Page 208: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

200 ADVANCED PROGRAMMING GUIDE

Code 93 Parameters Setting In this section, there are varies set up for Code 93 symbology, including: • Check character verification or transmission • Data redundant check • Min./Max. length setting

1. Check Digit

Code 93 check digit calculate but without transmit

Page 209: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

201 ADVANCED PROGRAMMING GUIDE

Code 93 check digit not calculate and without transmit

Code 93 check digit calculate and transmit

Page 210: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

202 ADVANCED PROGRAMMING GUIDE

2. Code 93 code reading length setting The default Code 93 code length is 3 ~32 character. It can be set at minimum 1 digit and maximum 62 digits.

Code Length Setting Flow

Code 93 maximum length setting

Programming Minimum or Maximum label

Scan two number label from Code39 FULL ASCII table.

Example:4 character length, scan “0”,”4”

Scan “save setting to confirm” label to confirm your choice into

memory.

Page 211: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

203 ADVANCED PROGRAMMING GUIDE

Code 93 minimum length setting

Save setting to confirm

Page 212: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

204 ADVANCED PROGRAMMING GUIDE

3. Data Redundant Check The option allows you to set decoder data redundant check before it is accepted as a good read. A higher data redundant check read setting offers more assurance that a barcode has been read correctly, while a lower setting allows faster scanning performance.

Code 93 data redundant check = 0

Code 93 data redundant check = 1

Page 213: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

205 ADVANCED PROGRAMMING GUIDE

Code 93 data redundant check = 2

Code 93 data redundant check = 3

Page 214: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

206 ADVANCED PROGRAMMING GUIDE

Full ASCII Code Table

Page 215: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

207 ADVANCED PROGRAMMING GUIDE

Full ASCII --- NUL

Full ASCII ---- SOH (Function Key---Ins)

Page 216: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

208 ADVANCED PROGRAMMING GUIDE

Full ASCII ----STX

(Function Key---Del)

Full ASCII ---- ETX (Function Key---Home)

Page 217: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

209 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- EOT

(Function Key---End)

Full ASCII ---- ENQ (Function Key---Up arrow)

Page 218: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

210 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- ACK

(Function Key---Down arrow)

Full ASCII ---- BEL (Function Key---Left arrow)

Page 219: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

211 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- BS

(Function Key---Backspace)

Full ASCII ---- HT (Function Key---Tab)

Page 220: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

212 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- LF

(Function Key---Enter(num))

Full ASCII ---- VT (Function Key---Right arrow)

Page 221: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

213 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- FF

(Function Key---PgUp)

Full ASCII ---- CR (Function Key---Enter(alphabet))

Page 222: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

214 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- SO

(Function Key---PgDn)

Full ASCII ---- SI (Function Key---Shift)

Page 223: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

215 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- DLE

(Function Key---5(num))

Full ASCII ---- DC1 (Function Key---F1)

Page 224: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

216 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- DC2 (Function Key---F2)

Full ASCII ---- DC3 (Function Key---F3)

Page 225: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

217 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- DC4 (Function Key---F4)

Full ASCII ---- NAK (Function Key---F5)

Page 226: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

218 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- SYN (Function Key---F6)

Full ASCII ---- ETB (Function Key---F7)

Page 227: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

219 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- CAN (Function Key---F8)

Full ASCII ---- EN (Function Key---F9)

Page 228: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

220 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- SUB

(Function Key---F10)

Full ASCII ---- ESC (Function Key---F11)

Page 229: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

221 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- FS

(Function Key---F12)

Full ASCII ---- GS (Function Key---ESC)

Page 230: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

222 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- RS

(Function Key---Ctl(L))

Full ASCII ---- US (Function Key---Alt(L))

Page 231: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

223 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- SP

Full ASCII ---- !

Page 232: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

224 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- “

Full ASCII ---- #

Page 233: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

225 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- $

Full ASCII ---- %

Page 234: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

226 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- &

Full ASCII ---- ‘

Page 235: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

227 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- (

Full ASCII ---- )

Page 236: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

228 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- *

Full ASCII ---- +

Page 237: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

229 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- ,

Full ASCII ---- -

Page 238: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

230 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- .

Full ASCII ---- /

Page 239: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

231 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- 0

Full ASCII ---- 1

Page 240: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

232 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- 2

Full ASCII ---- 3

Page 241: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

233 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- 4

Full ASCII ---- 5

Page 242: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

234 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- 6

Full ASCII ---- 7

Page 243: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

235 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- 8

Full ASCII ----9

Page 244: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

236 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- :

Full ASCII ---- ;

Page 245: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

237 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- <

Full ASCII ---- =

Page 246: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

238 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- >

Full ASCII ---- ?

Page 247: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

239 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- @

Full ASCII ---- A

Page 248: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

240 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- B

Full ASCII ---- C

Page 249: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

241 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- D

Full ASCII ---- E

Page 250: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

242 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- F

Full ASCII ---- G

Page 251: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

243 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- H

Full ASCII ---- I

Page 252: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

244 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- J

Full ASCII ---- K

Page 253: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

245 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- L

Full ASCII ---- M

Page 254: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

246 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- N

Full ASCII ---- O

Page 255: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

247 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- P

Full ASCII ---- Q

Page 256: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

248 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- R

Full ASCII ---- S

Page 257: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

249 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- T

Full ASCII ---- U

Page 258: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

250 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- V

Full ASCII ---- W

Page 259: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

251 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- X

Full ASCII ---- Y

Page 260: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

252 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- Z

Full ASCII ---- [

Page 261: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

253 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- \

Full ASCII ---- ]

Page 262: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

254 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- ^

Full ASCII ---- _

Page 263: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

255 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- `

Full ASCII ---- a

Page 264: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

256 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- b

Full ASCII ---- c

Page 265: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

257 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- d

Full ASCII ---- e

Page 266: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

258 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- f

Full ASCII ---- g

Page 267: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

259 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- h

Full ASCII ---- i

Page 268: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

260 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- j

Full ASCII ---- k

Page 269: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

261 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- l

Full ASCII ---- m

Page 270: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

262 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- n

Full ASCII ---- o

Page 271: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

263 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- p

Full ASCII ---- q

Page 272: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

264 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- r

Full ASCII ---- s

Page 273: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

265 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- t

Full ASCII ---- u

Page 274: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

266 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- v

Full ASCII ---- w

Page 275: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

267 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- x

Full ASCII ---- y

Page 276: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

268 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- z

Full ASCII ---- {

Page 277: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

269 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- |

Full ASCII ---- }

Page 278: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

270 ADVANCED PROGRAMMING GUIDE

Full ASCII ---- ~

Full ASCII ---- DEL

Page 279: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

271 ADVANCED PROGRAMMING GUIDE

APPENDIXES

Page 280: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

272 ADVANCED PROGRAMMING GUIDE

APPENDIX A CODE 39 FULL ASCII CODE TABLE

ASCII CODE 39 VALEUR HEXA. ASCII CODE 39 VALEUR HEXA.NUL %U 00 % /E 25

SOH $A 01 & /F 26

STX $B 02 ' /G 27

ETX $C 03 ( /H 28

EOT $D 04 ) /I 29

ENQ $E 05 * /J 2A

ACK $F 06 + /K 2B

BEL $G 07 , /L 2C

BS $H 08 - - 2D

HT $I 09 . . 2E

LF $J 0A / / 2F

VT $K 0B 0 0 30

FF $L 0C 1 1 31

CR $M 0D 2 2 32

SO $N 0E 3 3 33

SI $O 0F 4 4 34

DLE $P 10 5 5 35

DC1 $Q 11 6 6 36

DC2 $R 12 7 7 37

DC3 $S 13 8 8 38

DC4 $T 14 9 9 39

NAK $U 15 : /Z 3A

SYN $V 16 ; %F 3B

ETB $W 17 < %G 3C

CAN $X 18 = %H 3D

EM $Y 19 > %I 3E

SUB $Z 1A ? %J 3F

ESC %A 1B @ %V 40

FS %B 1C A A 41

GS %C 1D B B 42

RS %D 1E C C 43

US %E 1F D D 44

SP SP 20 E E 45

! /A 21 F F 46

" /B 22 G G 47

# /C 23 H H 48

$ /D 24 I I 49

Page 281: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

273 ADVANCED PROGRAMMING GUIDE

APPENDIX A CODE 39 FULL ASCII CODE TABLE

ASCII CODE 39 VALEUR HEXA. ASCII CODE 39 VALEUR HEXA.

J J 4A e +E 65

K K 4B f +F 66

L L 4C g +G 67

M M 4D h +H 68

N N 4E i +I 69

O O 4F j +J 6A

P P 50 k +K 6B

Q Q 51 l +L 6C

R R 52 m +M 6D

S S 53 n +N 6E

T T 54 o +O 6F

U U 55 p +P 70

V V 56 q +Q 71

W W 57 r +R 72

X X 58 s +S 73

Y Y 59 t +T 74

Z Z 5A u +U 75

[ %K 5B v +V 76

\ %L 5C w +W 77

] %M 5D x +X 78

^ %N 5E y +Y 79

_ %O 5F z +Z 7A

` %W 60 { %P 7B

a +A 61 | %Q 7C

b +B 62 } %R 7D

c +C 63 ~ %S 7E

d +D 64 DEL %T 7F

Page 282: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

274 ADVANCED PROGRAMMING GUIDE

APPENDIX B FUNCTION KEY EMULATION

FUNCTION KEY ASCII CODE 39 FUNCTION KEY ASCII CODE 39

Ins $A 01 F1 $Q 11

Del $B 02 F2 $R 12

Home $C 03 F3 $S 13

End $D 04 F4 $T 14

Up $E 05 F5 $U 15

Down $F 06 F6 $V 16

Left $G 07 F7 $W 17

Backspace $H 08 F8 $X 18

TAB $I 09 F9 $Y 19

Enter(num) $J 0A F10 $Z 1A

Right $K 0B F11 %A 1B

PgUp $L 0C F12 %B 1C

Enter $M 0D ESC %C 1D

PgDn $N 0E Ctl(L) %D 1E

shift $O 0F Alt(L) %E 1F

5 (num) $P 10

Page 283: Enter/Exit Programming Mode - Support Technique AURES PS-50... · This can be determined by turning the equipment off and on. ... ACK/NAK response time setting ... Scan the “Enter/Exit

275 ADVANCED PROGRAMMING GUIDE

Enter/Exit programming