CONTINUOUS CASTING 34 www.steeltimesint.com March 2017 ELECTROMAGNETIC flow control is a well-proven technology for improving quality in continuous slab casting [1]-[4] . Electromagnetic stirrers, based on the principles of travelling magnetic fields, have been shown as particularly efficient for flow acceleration, temperature homogenisation and inclusion washing in surface/sub- surface regions of the strand. Different configurations of static magnetic fields have also been utilised to brake and stabilise high speed processes. For varying casting conditions such as throughput, slab format, slag type, steel grade, argon flow injection, SEN type and immersion depth mold level and so on, different electromagnetic settings are needed to create the best possible flow conditions. Appropriate settings can be found through trials where an experience database can slowly be built up, or by numerically simulating the process with modern computer technology and software. Both methods, however, are very time-consuming. The OptiMold Monitor has been developed to measure flow conditions online, in real-time and adjust the flow control device accordingly. This technology provides superior thermal monitoring 1ABB AB, Terminalvägen 24, SE-721 59 Västerås, Sweden, 2 Tata Steel Europe, P.O. Box 10000, 1970CA IJmuiden, Netherlands, 3 Proximion AB, Skalholtsgatan 10, SE-164 40 Kista, Sweden Enhancing mold flow control Tata Steel Europe (Ijmuiden) has installed an OptiMold monitoring system, co-developed by ABB and Proximion. The system was developed to measure flow conditions online, in real-time, and adjust the flow control device accordingly. By Martin Sedén 1 , Jan-Erik Eriksson 1 , Arnoud Kamperman 2 , Edward Dekker 2 , Johan Pejnefors 3 and Krister Fröjdh 3 OptiMold monitor Harsh environment collector cable Harsh environment connection box Mold copper plate with inserted optical fibers Transport cable Interrogator unit OptiMold data analysis unit Mold EM device OptiMold control Fig 1. Schematic setup of OptiMold monitor 0.1 0.2 Mold temperatures [°C] z, from ToC [m] 0.3 -0.5 x [m] 0 0.5 200 150 100 50 0.1 0.2 Mold temperatures [°C] z, from ToC [m] 0.3 -0.5 x [m] 0 0.5 200 150 100 50 0.1 0.2 Mold temperatures [°C] z, from ToC [m] 0.3 -0.5 x [m] 0 0.5 200 150 100 50 Fig 2. Time averaged OptiMold monitor 2D heat maps for different FC Mold magnetic field configurations (Bbottom/Btop) a) 100%/57% b) 69%/57% c) 69%/0%
3

Enhancing mold flow control - ABB Group...Enhancing mold flow control Tata Steel Europe (Ijmuiden) has installed an OptiMold monitoring system, co-developed by ABB and Proximion. The

Mar 30, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Enhancing mold flow control - ABB Group...Enhancing mold flow control Tata Steel Europe (Ijmuiden) has installed an OptiMold monitoring system, co-developed by ABB and Proximion. The

CONTINUOUS CASTING34

www.steeltimesint.com March 2017

ELECTROMAGNETIC flow control is a well-proven technology for improving quality in continuous slab casting[1]-[4]. Electromagnetic stirrers, based on the principles of travelling magnetic fields, have been shown as particularly efficient for flow acceleration, temperature homogenisation and inclusion washing in surface/sub-surface regions of the strand. Different configurations of static magnetic fields have also been utilised to brake and stabilise high speed processes. For varying casting conditions such as throughput, slab format, slag type, steel grade, argon flow injection, SEN type and immersion depth mold level and so on, different electromagnetic settings are needed to create the best possible flow conditions. Appropriate settings can be found through trials where an experience database can slowly be built up, or by numerically simulating the process with modern computer technology and software. Both methods, however, are very time-consuming. The OptiMold Monitor has been developed to measure flow conditions online, in real-time and adjust the flow control device accordingly. This technology provides superior thermal monitoring

1ABB AB, Terminalvägen 24, SE-721 59 Västerås, Sweden, 2 Tata Steel Europe, P.O. Box 10000, 1970CA IJmuiden, Netherlands, 3 Proximion AB, Skalholtsgatan 10, SE-164 40 Kista, Sweden

Enhancing mold flow control

Tata Steel Europe (Ijmuiden) has installed an OptiMold monitoring system, co-developed by ABB and Proximion. The system was developed to measure flow conditions online, in real-time, and adjust the flow control device accordingly. By Martin Sedén1, Jan-Erik Eriksson1, Arnoud Kamperman2, Edward Dekker2, Johan Pejnefors3 and Krister Fröjdh3

OptiMold monitor

Harsh environment collector cable

Harsh environment connection box

Mold copper plate with inserted optical fibers

Transport cable

Interrogator unit

OptiMold data analysis unit

Mold EM device

OptiMold control

Fig 1. Schematic setup of OptiMold monitor

0.1

0.2

Mold temperatures [°C]

z, fr

om T

oC [m

]

0.3

-0.5x [m]

0 0.5

200

150

100

50

0.1

0.2

Mold temperatures [°C]

z, fr

om T

oC [m

]

0.3

-0.5x [m]

0 0.5

200

150

100

50

0.1

0.2

Mold temperatures [°C]

z, fr

om T

oC [m

]

0.3

-0.5x [m]

0 0.5

200

150

100

50

Fig 2. Time averaged OptiMold monitor 2D heat maps for different FC Mold magnetic field configurations (Bbottom/Btop)

a) 100%/57% b) 69%/57% c) 69%/0%

Page 2: Enhancing mold flow control - ABB Group...Enhancing mold flow control Tata Steel Europe (Ijmuiden) has installed an OptiMold monitoring system, co-developed by ABB and Proximion. The

CONTINUOUS CASTING 35

www.steeltimesint.com March 2017

resolution and has been co-developed by ABB and Proximion. It is installed at Tata Steel Europe (Ijmuiden).

Measurement system and test set-upThe core of the installed OptiMold Monitor (Fig. 1) is a set of 38 measuring optical fibres. One end is mounted into evenly spaced vertical holes in the top half of a new copper broad face plate, 15mm from the hot face, and the other end is spliced into a multi-strand harsh environment collector cable in a connection box mounted on the side of the mold plate. At the mold end of each fibre, 70 Fibre Bragg Gratings (FBGs) have been accurately positioned every 5mm,[5] starting 30mm from the top of the copper plate and covering the upper broad face down to 375mm from the top of the copper. Each FBG acts as a single temperature sensor, equipping the broad face plate with a total of 2,660 sensors. See[10] for system set-up details.

Using robust, expanded beam connectors, four 15m long collector cables

are plugged in to an intermediate box positioned close to the caster. From the intermediate box, the optical transmission is carried by a 125m transport cable, which connects all the caster fibres to interrogators in a climate-controlled room. The light source in the interrogator sends a broadband light pulse into the fibres. Reflections caused by the FBGs are picked up by the interrogator unit and translated by software to temperature data for all sensor points. Temperature data is scanned and treated online for the entire mold plate twice every second.

High resolution temperature mappings The slab caster at Tata Steel Europe (IJmuiden), where the OptiMold Monitor has been installed, is also equipped with an ABB FC Mold, a two-level electromagnetic brake controlling the flow of molten steel in the mold. During a trial, the FC Mold’s magnetic fields were varied, as the OptiMold Monitor scanned the thermal status of the mold.

The time-averaged temperature

mappings (Fig. 2) show that a strong magnetic field (2a) results in a relatively homogeneous temperature distribution. For a vanishing top magnetic field (2c), temperature distribution becomes inhomogeneous with accentuated hot-spots close to the narrow faces.

Meniscus shape has been estimated based on measured temperature distributions. Fig. 3 illustrates the resulting time average calculated meniscus shape for the FC Mold configurations described above for the 1100mm width, 190 mm SEN immersion depth and 1.9 m/min casting speed.

The estimated meniscus shape results indicate that the stronger top magnetic fields ensure a lower wave peak close to the narrow faces, whereas the meniscus wave height is much more pronounced for the un-braked top domain. In Fig.4, an estimate of dynamic meniscus fluctuations is shown. It also indicates a stabilisation over the entire width of the mold with the application of magnetic fields.

A set of numerical simulations of molten

6

5

4

3

2

1

00.05

σT[°

C]

0.1 0.15

Bbottom = 100%, Btop =57%

Bbottom = 69%, Btop =57%

Bbottom = 69%, Btop =0%

x = 425mm

Coordinate below ToC [m]

0.2 0.25 0.3 0.35

60

70

80

90

100

110

Bbottom = 100%, Btop =57%

Bbottom = 69%, Btop =57%

Bbottom = 69%, Btop =0%

Coordinate along mold width [m]-0.5 0

z, A

vg. m

enisc

us w

ave

[mm

]

-0.5

Fig 4. Standard deviation of the meniscus height over the entire mold width for different FC Mold settings

80

70

60

50

40

30

20

10

0

0

0.5

1

-1016:30:00 16:45:00 17:00:00 17:15:00 17:30:00 17:45:00 17:45:00 18:00:00 18:30:00

hL, [mm]

hR, [mm]mtundish[ton]]

Fig 5. Calculated meniscus flow speeds, left and right hand side of mold, for different FC mold configurations

Fig 6. Monitored left and right hand side estimated meniscus wave heights (hL and hR) for last 2 heats before tundish and SEN change

Fig 3. Meniscus shape along the width of the mold for different FC mold settings.Estimated from measured temperature

0.5

0.4

0.3

0.2

0.1

00 4020 60 80 100 120

VL, Bbottom = 100%,Btop = 57% VR Bbottom = 100%,Btop = 57%

VR Bbottom = 69%,Btop = 57%

VR Bbottom = 69%,Btop = 0%

VL, Bbottom = 69%,Btop = 57%

VL, Bbottom = 69%,Btop = 0%

Avg.

men

iscus

flow

spe

ed [m

/s]

Time [s]

Page 3: Enhancing mold flow control - ABB Group...Enhancing mold flow control Tata Steel Europe (Ijmuiden) has installed an OptiMold monitoring system, co-developed by ABB and Proximion. The

CONTINUOUS CASTING36

www.steeltimesint.com March 2017

steel flow in the mold was produced to illustrate the causes of the observed meniscus shapes and flow speeds. The CFD-simulated meniscus shapes are very similar to the OptiMold Monitor’s estimated meniscus shapes shown in Fig. 3. As the top magnetic field is missing, the flow pattern shows a strong upward directed flow along the upper part of the narrow faces. This vertical momentum pushes the meniscus wave upward and creates a high crest of potential energy close to the narrow face; energy that is converted into kinetic energy in the form of meniscus flow speed towards the SEN. For the stronger top magnetic field, the upper recirculation loop is restricted in speed and hence has a flatter meniscus with lower flow speeds. A strong bottom field restricts downward-directed flow momentum, reducing the penetration depth of the lower recirculation loop.

Meniscus flow speed can be calculated based on the meniscus shape. In Fig. 5 the variation of meniscus flow speed is given over the two-minute trial period. The connection between the top magnetic field and meniscus general flow speed level is apparent. It is also clear that the unbraked high flow speeds undergo large fluctuations as well as left/right-asymmetry over time. A stable meniscus flow level around 0.3 m/s is in this 237x1100 mm, 1.9 m/min casting sequence found for an FC Mold field setting of 57%/100% (top/bottom).

Meniscus speed controlImplementing the algorithms for meniscus profile and meniscus flow speed in the OptiMold system analysis unit, the deduced in-mold flow speeds can be monitored over time. In Fig. 6 the meniscus wave height has been monitored over the last two heats of a casting sequence before tundish and SEN change.

Before the ladle change at 17:14, temperature distribution and meniscus wave are relatively symmetric. In the last part of the sequence, asymmetry becomes more pronounced, biasing the meniscus wave on the left side. It can be concluded that clogging affects flow pattern symmetry in the last stages of casting.

These results reveal the OptiMold Monitor’s potential in conjunction with a flow control device for counteracting and controlling in-mold flow asymmetries as soon as they are detected by the temperature measurements. A modern generation FC Mold has the ability to

control left and right side magnetic fields independently and consequently apply different electro-magnetic forces to the mold flow on the left and right sides, and is a perfect fit for OptiMold Control to regulate symmetry as well as the appropriate flow speed levels in real time.

ConclusionsBy means of high-resolution temperature measurements the OptiMold Monitor can allow for powerful analysis of casting conditions and detection of mold flow pattern characteristics such as meniscus shape, flow velocity and flow asymmetry. This opens up new possibilities for enhancing mold flow control where it can, in a closed-loop connection to an electromagnetic actuator, dampen or accelerate flow speeds as well as control flow asymmetry. What’s more, the OptiMold Monitor can extend functionality and performance of conventional thermocouple systems and detect local thermal phenomena. Fibre-optics measure undisturbed in the presence of magnetic fields.

To read the white paper that this article is based on or for more information on our offerings visit www.abb.com/metals �

References[1] S. Kenichiro et al., “Flow field control of

liquid steel in the mold of a continuous slab

caster by an electromagnetic brake”, Tetsu-to-

Hagane (1983), Vol. 69, No.12, pp. 912

[2] H. Okuda et al., “Effects of electro-magnetic

brake on surface quality of medium carbon

strand cast slabs”, Tetsu-to-Hagane (1986), Vol.

72, No.4, pp. 196

[3] H. Yamamura, T. Toh et al., “Optimum

magnetic flux density in quality control of casts

with level DC magnetic field in continuous

casting mold”, ISIJ International (2001), Vol.41,

No. 10, pp.1229-1235

[4] Y. Miki, S. Takeuchi, “Internal defects of

continuous casting slabs caused by asymmetric

unbalanced steel flow in mold”, ISIJ International

(2003), Vol. 43, No. 10, pp. 1548-1555

[5] A. Asseh et al.,”A writing technique for long

fibre Bragg gratings with complex reflectivity

profiles”, Lightwave Technology, Volume 15,

1997, Issue 8, pp. 1419-1423.

[6] G. Hedin, A. Kamperman, M. Sedén, K.

Fröjdh, J. Pejnefors, “Exploring Opportunities

in Mold Temperature Monitoring Utilising Fibre

Bragg Gratings”, Presented at SCANMET V,

(Luleå, 2016).

BILLETCOOLER

FLEX your cooling.

Lechler GmbHP. O. Box 13 23 72544 Metzingen, GermanyPhone +49 7123 962-0 [email protected]

5 good reasons for a new secondary cooling systemNew steel types and formats call for new approaches to secondary cooling. Both cooling performance and water application must be precisely adjusta ble. With the Billetcooler FLEX®, we’ve developed a twin-fl uid nozzle o� ering exactly that – and much more.

Stable spray angle over turndown ratio

Flexible spray characteristics for every format and steel grade

Non-clogging due to large cross sections

Low air consumption HTC designed air mist nozzle

NEW for billet and bloomcontinuous casting machines

www.billetcooler-fl ex.com