Top Banner
MICO ® Mineral Insulated Cables KME Italy S.p.A. MICO ® [I] Member of the KME Group
32
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: English Brochure Mico_final

KME Italy S.p.A.

MICO®

Mineral Insulated Cables

KM

E It

aly

S.p.

A.

MIC

O® [I]

Member of theKME Group

Page 2: English Brochure Mico_final

WHAT IS KME

A major European industrial group which for more than a hundred years has been a leading force in the world of copper processing industryWorld leader in semi-finished copper productsKME Group is the world’s largest manufacturer of semi-finished copper and copper alloy products (excluding copper wire), with a share of 30% of the European market and 7% worldwide

Major production sitesThe Group boasts 14 production sites strategically located in the 5 European countries with the largest semi-finished products markets, as well as in China.

A hundred years of historyKME Group has deep roots in the history of European industry: it was founded and first quoted on the stock mar-kets in the 19th century.

Our product range includes a complete assortment of semi-finished copper and copper alloy products designed for use in numerous applications. We keep an open dialogue with our customers, so that we can work together to develop resourceful, economical solutions for all kinds of copper applications, old and new.

Roofing systemsKME offers copper as a basic material for architecture and building: surfaces and systems for roo-fing and facade cladding and for the draining of rainwater.

Copper Industrial TubesA high level of quality characterizes our copper tubes; their characteristics have been studied to meet the needs of various industrial applications: air conditioning and refrigeration systems, con-struction of boilers, making of high-frequency coaxial cables, fittings and the solar heating industry.

Brass and copper rodsKME has the widest range of brass and copper rods on the market, in every size and shape, for all fields of application, from architecture to the electrical industry.

Special productsWe are able to create highly technological products: piping systems for the marine industry, tube bundles, mineral insulated cables, special extruded and drawn products in every size and shape, and finished machined parts based on the customer’s design.

Plumbing systemsHigh performance copper tubes, both bare and covered, which are ideal for any plumbing and he-ating application in the building sector as well as for the distribution of medical gases in the heal-thcare industry.

Industrial Rolled productsKME manufactures rolled products made of copper, brass, bronze and other copper-based alloys in every shape and size and with different surface treatments in order to meet the requests from many industrial sectors.

Engineered productsKME is a worldwide leader in the supply of copper and special alloy components for the continuous casting of steel and non-ferrous metals, just as it is a qualified and professional partner in the desi-gning of these systems.

WATERPROOF STRAIGHT THROUGH JOINT

Page 3: English Brochure Mico_final

MICO® Characteristics 4Applications and advantages 5Light duty cables 7Heavy duty cables 9Fire resistance 10Mechanical resistance 13MICO®/plumbing copper tube comparison 14Technical data 16Mineral insulated cable Twisted 26MICO® assembled and tested in factory 27Mineral cables termination 28Fixing systems 29LSF sheathed Mineral cables 29Tools 29Junction boxes 30Waterproof straight through joint 31Reference list 32Reference list-Asia 34Approvals 35Mineral Insulated Heating Cables 36Industrial applications 37Building applications 38Technical data 38MICO® PLUS Self limiting cables 40Technical sheet of MICO® PLUS M 43Technical sheet of MICO® PLUS L 44Technical sheet of MICO® PLUS R 45Technical sheet of MICO® PLUS P 46Accessories 47

KME Italy S.p.A.

WATERPROOF STRAIGHT THROUGH JOINT

Page 4: English Brochure Mico_final

MICO®

Characteristics

4

MICO® Mineral Insulated Cable is composed by:

● ETP solid (not stranded) copper cores, from 1 to 400 mm2, melting point 1082°C

● Magnesium Oxide (MgO) as electrical insulation, due to its high performance at high temperature (melting point 2600°C)

● high quality DHP copper sheath, manufactured starting from tubes extruded and drawn only (not welded), melting point 1082°C

● LSF additional outer covering. Such flame retardant poliolephin is characterised by high performance in corrosion resistance and low smoke emission.

MICO® Cable range is divided into:

● Light duty cables (300/500 V) from 2 to 7 cores, from 1 to 4 mm2 size

● Heavy Duty Cables (450/750 V) from 1 to 19 cores, 400 mm2 ma-ximum size for single core, 25 mm2 maximum size up to 4 cores.

Production process held by KME foresee many steps of diameter re-duction (both drawings and rollings) separated by high temperature annealing. Long lead time (average is 8 weeks) grants high quality cable at the end of the process: strong compression of MgO powder (density about 2 kg/cm3) allows very high values of insulation resi-stance (also if burned, 180° bended or flattened) and thermal con-ductivity. Therefore current ratings are higher than soft skin cables, especially at high temperature.

Page 5: English Brochure Mico_final

KME Italy S.p.A.

Applications and advantages

5

FIRE RESISTANCE – weaker situation is copper melting point (1082°C) MICO® is the safest cable, it can withstand to severe fire, water and mechanical tests as foreseen by British (LPCB), European and australian stan-dards

EMERGENCY SYSTEMS – MICO® is the only cable to go on wor-king also during a fire, so to supply (for at least 120 minutes, maximum time 3 hours) emergency lamps, acoustic alarms, sprinklers, automatic doors, eleva-tors and so on

FIRE DETECTION – MICO® cables allow fire controller units to recei-ve signals by fire detectors also during a fire. MICO® twisted cables (for signal transmission), in addition to MICO® light duty cables (for power supply), are able to match technical requirements by most popular fire detection systems

BUS SYSTEMS – world leaders like ABB or Schneider Electric alrea-dy tested and approved MICO® as suitable cable for distribution in their bus systems, limiting MICO® specification in fire hazardous areas or in historical buildings, where standard bus cables need are not recommended

HISTORICAL BUILDINGS – standard electrical plant can deeply impact aesthetical aspect of old buildings: where integrity of original structure must be saved and hidden installation is not allowed (or its cost would be too much), MICO® is the perfect solution for an installation at sight. You can also trust on copper capacity of disappearing, day after day, if used on particular environment like stone, brick, wood.

TUNNELS – emergency lights and fan coils are required to go on working also during a fire, to allow people using emergency exits. In order to save their life, MICO® is really able to withstand high temperatures during a car fire.

Page 6: English Brochure Mico_final

MICO®

Fire resistance

CWZ

10

Furnace

Standard soft skin fire re-sistant cable before fire test

Temperature inside furnace according to standard ISO 91 curve: after 90’ it’s 1020°C (German fire test according to DIN 4102), after 120’ it’s 1050°C (Australian fire test according to AS 3013). Same test executed in Italy to classify MICO® as REI 90

Standard cable failure after few minutes of fire test

Soft skin cable insulation cracks and falls down after some mechani-cal hits

This is how soft skin fire resistant cable remains after few minutes of fire: would you trust on it ?

MICO® cable during fire test (950°C for 180 minutes)

MICO® cable during water test (650°C for 15 minutes, then water crush trough sprinklers)

MICO® cable during mechani-cal test (950°C again for 15 minutes then mechanical impact directly on the cable)

MICO® cables after all test: power supply is still granted

Page 7: English Brochure Mico_final

KME Italy S.p.A.

11

TunnelsFan coils, exit LEd ligths, emergency and standard lighting can continue to work if powered by MICO®

CinemaEmergency circuit - exit lamp still going on during a fire, if all systems are powered by MICO®

Page 8: English Brochure Mico_final

MICO®

Fire resistance

Building applicationsEmergency circuit - single core cables on fire proof cable conduit, to supply each level of building Elevator power supply

12

Elevator/Lift

Fire resistant cable conduit

Page 9: English Brochure Mico_final

KME Italy S.p.A.

Mechanical performance

Industrial applications

13

Flattening test: cable cross section reduced by 50%, connected to power - no breakdown

Bending test: 180° bending on one side (bending radius = 6 times cable diameter), 180° bending on opposite side, then connected to power - no breakdown

Page 10: English Brochure Mico_final

MICO® plumbing tube comparison

Electrical plant with MICO®

Electrical plant with standard cable and conduit (plumbing tube)

Power supply

Junction box

switch/socket

Lamp

Fixing clips

MICO® 2L1.5 cable

Ø 16 mm copper pipe

Elbow connection

14

MICO®

Page 11: English Brochure Mico_final

KME Italy S.p.A.

MICO®

5 m assembled pieceCOPPER TUBE

5 m assembled piece

2L1.5 MICO® CABLEseals GFT 2L1.5ISO glands 2L1.5locknuts C1copper clips 1N01

4L1.5 MICO® CABLEseals GFT 4L1.5ISO glands 4L1.5locknuts C1copper clips 1N02

26.55 €9.14 €

11.94 €2.1 €

6.16 €55.89 €

38.85 €9.14 €

11.94 €2.1 €

6.56 €68.59 €

5 m2 pcs2 pcs2 pcs

10 pcs

5 m2 pcs2 pcs2 pcs

10 pcs

5.31 €/m45.7 €/pack59.7 €/pack10.5 €/pack30.8 €/pack

7.77 €/m45.7 €/pack59.7 €/pack10.5 €/pack32.8 €/pack

COPPER TUBE diam. 16 mmstandard cable 2 x 1.5 + G2 elbows x 162 nipples x 16copper clamps

COPPER TUBE diam. 22 mmstandard cable 4 x 1.5 + G2 elbows x 222 nipples x 22copper clamps

28.35 €8.61 €3.7 €6.8 €

12.5 € 59.96 €

39.69 €12.715 €

5.2 €9.5 €22 €

89.105 €

5 m 2 pcs 1 pack 1 pack 10 pcs

5 m 5 pcs 1 pack 1 pack 10 pcs

5.67 €/m1.27 €/m 3.7 €/each 6.8 €/each1.25 €/each

7.938 €/m2.543 €/m 5.2 €/each 9.5 €/each 2.2 €/each

copper price ref: 5 €/kg - VAT not included

Copper fixing clips/clamps

MICO® 2L1.5 cableØ 16 mm copper pipe + fire resistant cable 3 x 1.5

Elbow connection

Earth tail seal

ISO brass gland

Nipple

15

Page 12: English Brochure Mico_final

16

Page 13: English Brochure Mico_final

17

Page 14: English Brochure Mico_final

Resistance R (Ω/km)Cabletype2L1

2L1.52L2.52L43L1

3L1.53L2.5

30 °C18.81112.575

7.7014.479

18.81112.575

7.701

70 °C21.65614.477

8.8665.157

21.65614.477

8.866

105 °C24.14516.141

9.8855.749

24.14516.141

9.885

0.0880.0830.0790.0750.0910.0860.079

Reactance X (Ω/km) Impedance Z (Ω/km)30 °C

18.81112.576

7.7024.480

18.81112.576

7.702

70 °C21.65614.477

8.8665.157

21.65614.477

8.866

105 °C24.14516.141

9.8855.749

24.14516.141

9.885

Above indicated values are valid also for multi-core cables with 4 & 7 conductors

Light duty multi-core cables (500 V): resistance, reactance & impedance

Resistance R (Ω/km)Cabletype

2H1.52H2.52H42H6

2H102H162H25

30 °C12.575

7.7014.7913.2001.9021.1950.756

70 °C14.477

8.8865.5163.6852.1901.3760.870

105 °C16.141

9.8856.1504.1092.4411.5340.970

0.1010.0940.0880.0830.0790.0750.073

Reactance X (Ω/km) Impedance Z (Ω/km)30 °C

12.5767.7024.7923.2011.9041.1980.759

70 °C14.478

8.8665.5163.6862.1911.3780.873

105 °C16.142

9.8856.1504.1102.4421.5360.973

Above indicated values are valid also for all the other types of multi-core cables (with 3, 4 ,7, 12 & 19 conductors).

Heavy duty two-core cables (750 V): resistance, reactance & impedance

Resistance R (Ω/km)Cabletype

1H1.51H2.51H41H6

1H101H161H251H351H501H701H95

1H1201H1501H1851H2401H3001H400

30 °C12.576

7.7024.7923.2021.9031.1960.7570.5460.4040.2810.2040.1630.1330.1090.0860.0760.075

70 °C14.478

8.8665.5163.6862.1901.3770.8710.6280.4650.3230.2340.1860.1520.1230.0960.0840.063

105 °C16.142

9.8856.15

4.1092.4421.5350.9710.7000.5180.3600.2600.2070.1690.1370.1060.0920.069

0.1390.1280.1200.1120.1040.0980.0930.0890.0850.0830.0800.0780.0770.0760.0760.0750.075

Reactance X (Ω/km) Impedance Z (Ω/km)30 °C

12.5777.7034.7933.2041.9061.2000.7630.5540.4130.2930.2190.1800.1540.1330.1150.1070.095

70 °C14.478

8.8675.5183.6872.1931.3800.8760.6350.4730.3330.2470.2020.1700.1450.1230.1130.099

105 °C16.142

9.8868.6504.1112.4441.5380.9750.7060.5250.3690.2720.2210.1850.1570.1310.1190.103

Single-core triplet cables: resistance, reactance & impedance

18

Page 15: English Brochure Mico_final

Resistance R (Ω/km)Cabletype

Cabletype

1H1.51H2.51H41H6

1H101H161H251H351H501H701H95

1H1201H1501H1851H2401H3001H400

1H1.51H2.51H41H6

1H101H161H251H351H501H701H95

1H1201H1501H1851H2401H3001H400

30 °C

Reactance X (Ω/km) Impedance Z (Ω/km)

Single-core cables laid side by side: resistance, reactance & impedance

12.617.7404.8313.2411.9421.2360.7970.5870.4460.3230.2460.2060.1770.1540.1320.1220.104

12.577.7024.7923.2021.9031.1960.7570.5460.4040.2800.2030.1610.1320.1070.0830.0730.054

12.537.6654.7553.1661.8671.1610.7220.5120.3710.2490.1720.1320.1040.0830.0630.0560.038

R S T14.518.9055.5553.7252.2291.4160.9110.6690.5060.3640.2760.2290.1950.1680.1420.1300.110

14.478.8665.5163.6862.1901.3770.8710.6280.4640.3220.2330.1850.1510.1220.0950.0820.061

14.448.8295.4803.6492.1541.3410.8360.5940.4310.2900.2010.1550.1220.0960.0720.0620.042

70 °CR S T

16.189.9246.1894.1482.4811.5741.011

0.740.5580.4010.3020.2490.2120.1810.1520.1370.115

16.149.8856.1504.1092.4421.5350.9710.7000.5170.3590.2590.2060.1680.1350.1040.0900.067

16.109.8486.1134.0732.4061.4990.9350.6650.4830.3260.2270.1750.1380.1080.0810.0680.046

105 °CR S T

30 °CR S T

70 °CR S T

105 °CR S TR S T

0.1600.1490.1400.1320.1240.1170.1120.1070.1030.0990.0960.0930.0900.0860.0820.0780.077

0.1390.1280.1200.1120.1040.0980.0930.0890.0850.0830.0800.0780.0770.0770.0770.0760.076

0.1610.1500.1420.1350.1270.1210.1170.1130.1100.1080.1060.1050.1040.1040.1040.1030.103

12.617.7424.8333.2441.9461.2420.8050.5970.4570.3380.2640.2260.1990.1770.1550.1450.129

12.577.7034.7933.2041.9051.2000.7620.5530.4130.2920.2180.1790.1530.1320.1130.1050.094

12.547.6674.7573.1681.8711.1670.7310.5240.3870.2710.2020.1690.1470.1330.1220.1170.110

14.528.9065.5573.7272.2331.4210.9180.6770.5160.3780.2920.2480.2160.1900.1660.1530.136

14.488.8675.5173.6872.1931.3800.8760.6340.4720.3330.2460.2010.1690.1440.1220.1120.098

14.448.8315.4823.6522.1581.3470.8440.6040.4450.3090.2270.1870.1600.1410.1270.1210.112

16.189.9256.1904.1502.4841.5791.0170.7480.5680.4130.3170.2670.2310.2020.1750.1610.142

16.149.8866.1514.1112.4441.5380.9750.7060.5240.3680.2710.2200.1850.1560.1300.1180.102

16.109.8506.1154.0752.4091.5040.9430.6750.4960.3430.2500.2030.1720.1500.1320.1240.114

19

Page 16: English Brochure Mico_final

Resistance R (Ω/km)Cabletype

1H1.51H2.51H41H6

1H101H161H251H351H501H701H95

1H1201H1501H1851H2401H3001H400

30 °C

Single-core cables laid at the distance of a diameter: resistance, reactance & impedance

12.617.7434.8333.2441.946

1.240.8030.5930.4530.3320.2570.2170.1900.1690.1480.1390.120

12.577.7034.7933.2031.9051.1990.7600.5500.4090.2870.2100.1700.1420.1200.1000.0930.075

12.547.7674.7283.1691.8701.1650.7280.5190.3790.2590.1850.1470.1210.1050.1410.0850.069

R S T14.528.9075.5573.7272.2321.4200.9160.6740.5120.3720.2850.2390.2070.1820.1580.1470.126

14.488.8675.5183.6872.1921.3790.8740.6320.4690.3280.2390.1930.1600.1340.1100.0990.079

14.448.8315.4823.6522.1571.3450.8410.6000.4380.2990.2120.1680.1370.1160.0970.0880.071

70 °CR S T

16.189.9256.1914.1502.4841.5781.0150.7450.5640.4080.3100.2590.2220.1940.1670.1540.131

16.149.8866.1514.1112.4431.5370.9730.7030.5210.3640.2650.2130.1760.1460.1180.105

0.83

16.109.8506.1154.0752.4081.5020.9400.6710.4900.3340.2370.1860.1510.1260.1030.0920.073

105 °CR S T

Cabletype

1H1.51H2.51H41H6

1H101H161H251H351H501H701H95

1H1201H1501H1851H2401H3001H400

Reactance X (Ω/km) Impedance Z (Ω/km)30 °C

R S T70 °C

R S T105 °C

R S TR S T0.2030.1920.1830.1750.1670.1600.1540.1500.1450.1400.1360.1330.1290.1230.1160.1120.108

0.1820.1710.1630.1560.1480.1410.1360.1320.1290.1260.1230.1210.1200.1990.1170.1150.115

0.2050.1940.1860.1790.1710.1650.1610.1570.1540.1520.1500.1490.1470.1470.1450.1430.142

12.617.7454.8373.2481.9531.2500.8170.6110.4750.3600.2890.2530.2270.2050.1830.1720.155

12.577.7054.7963.2071.9111.2070.7720.5660.4290.3130.2440.2090.1850.1680.1530.1460.135

12.547.6704.7623.1741.8781.1770.7460.5430.4100.3010.2390.2090.1900.1790.1680.1620.152

14.528.9075.5603.7312.2391.4290.9280.6900.5320.3980.3150.2730.2430.2180.1940.1820.163

14.488.8675.5203.6912.1971.3860.8840.6450.4860.3510.2690.2280.1990.1780.1600.1510.139

14.448.8315.4853.6562.1641.3550.8560.6200.4650.3360.2600.2240.2010.1870.1730.1660.160

16.189.9276.1944.1542.4891.5861.0260.7600.5830.4310.3390.2910.2570.1940.2030.1900.170

16.149.8886.1544.1142.4481.5430.9830.7160.5370.3850.2920.2450.2130.1460.1660.1560.142

16.109.8526.1184.0792.4141.5110.9540.6890.5140.3670.2810.2380.2110.1260.1780.1700.159

20

Page 17: English Brochure Mico_final

Voltage drop (mV/Am)cabletype

1H1.51H2.51H41H6

1H101H161H251H351H501H701H95

1H1201H1501H1851H2401H3001H400

30 °C21.78013.340

8.3005.5503.3002.0701.3100.9500.7000.4900.3500.2800.2300.1900.1500.1300.099

Voltage drop in single-core triplet cables

cos φ = 1 cos φ = 0.8

70 °C25.08015.360

9.5506.3803.7902.3801.5101.0900.8100.5600.4000.3200.2600.2100.2100.1500.110

105 °C27.96017.12010.650

7.1204.2302.6601.6801.2100.9000.6200.4500.3600.2900.2400.1800.1600.120

30 °C17.57010.800

6.7604.5502.7401.7601.1500.8500.6500.4800.3700.3100.2600.2300.2000.1800.160

70 °C20.21012.420

7.7705.2203.1402.0101.3000.9600.7300.5300.4100.3400.2800.2500.2500.1900.170

105 °C22.51013.830

8.6505.8103.4902.2301.4401.0600.8100.5800.4400.3700.3100.2700.2300.2100.170

Voltage drop (mV/Am)cabletype

1H1.51H2.51H41H6

1H101H161H251H351H501H701H95

1H1201H1501H1851H2401H3001H400

30 °C21.78013.340

8.3005.5503.3002.0701.3100.9500.7000.4900.3500.2800.2300.1900.1500.1300.099

Voltage drop in single-core cables laid side by side

cos φ = 1 cos φ = 0.8

70 °C25.08015.360

9.5506.3803.7902.3801.5101.0900.8100.5600.4000.3200.2600.2100.2100.1500.110

105 °C27.96017.12010.650

7.1204.2302.6601.6801.2100.9000.6200.4500.3600.2900.2400.1800.1600.120

30 °C17.57010.800

6.7604.5502.7401.7601.1500.8500.6500.4800.3700.3100.2600.2300.2000.1800.160

70 °C20.21012.420

7.7705.2203.1402.0101.3000.9600.7300.5300.4100.3400.2800.2500.2500.1900.170

105 °C22.51013.830

8.6505.8103.4902.2301.4401.0600.8100.5800.4400.3700.3100.2700.2300.2100.170

21

Page 18: English Brochure Mico_final

Voltage drop (mV/Am)cabletype

1H1.51H2.51H41H6

1H101H161H251H351H501H701H95

1H1201H1501H1851H2401H3001H400

30 °C21.79013.340

8.3005.5503.3002.0601.3200.9600.7200.5100.3800.3100.2600.2300.2000.1800.150

Voltage drop in single-core cables laid at the distance of a diameter

cos φ = 1 cos φ = 0.8

70 °C25.08015.360

9.5606.3903.8002.3901.5201.1000.8200.5800.4300.3500.2900.2500.2100.1900.160

105 °C27.96017.13010.660

7.1204.2402.6701.6901.2200.9100.6400.4700.3800.3200.2700.2200.2000.170

30 °C17.63010.870

6.8304.6202.8101.8301.2100.9200.7200.5500.4400.3800.3400.3100.2800.2700.240

70 °C20.27012.480

7.8305.2903.2102.0801.3701.0300.8000.6100.4800.4200.3700.3300.3000.2800.250

105 °C22.57013.890

8.7105.8703.5602.2901.5101.1300.8800.6600.5200.4400.3900.3500.3100.2900.260

Voltage drop (mV/Am)cabletype

2L12L1.52L2.52L43L1

3L1.53L2.5

30 °C37.62025.15015.400

8.96032.58021.78013.340

Voltage drop in Light duty multi-core cables (500 V)

cos φ = 1 cos φ = 0.8

70 °C43.31028.95017.73010.310

37.5125.08015.360

105 °C48.29032.28019.77011.50041.82027.96017.120

30 °C30.20020.22012.420

7.26026.16017.51010.750

70 °C34.76023.26014.280

8.34030.10020.15012.370

105 °C38.74025.93015.910

9.29033.55022.46013.780

Above indicated values are valid also for multi-core cables with 4 & 7 conductors.

Voltage drop (mV/Am)cabletype

2H1.52H2.52H42H6

2H102H162H25

30 °C25.15015.400

9.5806.4013.8002.3901.510

Voltage drop in Light duty multi-core cables (750 V)

cos φ = 1 cos φ = 0.8

70 °C28.95017.73011.030

7.3704.3802.7501.740

105 °C32.28019.77012.300

8.2204.8803.0701.940

30 °C20.24012.430

7.7705.2203.1402.0001.300

70 °C23.28014.300

8.9306.0003.6002.2901.480

105 °C25.95015.930

9.9406.6704.0002.5401.640

Above indicated values are valid also for all the other types of multi-core cables (with 3, 4 ,7, 12 & 19 conductors).

22

Page 19: English Brochure Mico_final

single-core H (750 V) M.I.C. bare, exposed to touch or covered with thermoplastic material (metal she-ath maximum temperature 70°C). For bare cables we must multiply by 0.9. Cables sheaths are connected to the ends.

cabletype

1H1.51H2.51H41H6

1H101H161H251H351H501H701H95

1H1201H1501H1851H240

(A)223040516992

120147182223267308352399466

(A)2636476082

109142174215264317364416472552

(A)2634455777

102132161198241289331377426496

(A)2636476082

109142174215264317364416472552

(A)3243567195

125162197242294351402454507565

(A)2636476082

109142174215264317364416472552

nominal conductor

cross section

mm2 2 cables

(A)

212837

223040516992

120

233140

2534455777

102133

multi-core H (750 V) e L (500 V) M.I.C. bare, exposed to touch or covered with thermoplastic material (metal sheath maximum temperature 70°C). For bare cables we must multiply by 0.9.

cable in air, spaced from wall or ceiling or on platform

192635

212837486586

112

500 V1.52.54

750 V1.52.546

101625

Table I/1

triplet cables in

air

laid side by side cables in air

horizontal spaced cables in air

vertical spaced cables in air

laid cables in air, fixed on wall or

ceiling

triplet cables in air, fixed

on wall or ceiling

(A)2837496284

110142173213259309353400446497

(A)2534455777

102133163202247296340388440514

(A)233141527092

120147181221264303346392457

(A)212837486586

112137169207249286327371434

13-1415-16 *

13-1415-16 *

1415-16 *

1415-16 *

1111A *

1111A *

3 cables 2 cables 3 cables 2 cables 3 cables 2 cables 3 cables 2 cables 3 cables 3 cables

Table II/1

cable in air, fixed on wall or ceiling

3-14-15-16 * 11-11A *

253344

2637476082

109142

3 cables

(A)

2 cables

(A)

3 cables

(A)serie

* Installation methods taken from 3rd edition of CEI 64-8/5 norm, table 52 C

23

Page 20: English Brochure Mico_final

single-core H (450/750 V) M.I.C. bare, not exposed to touch (metal sheath maximum temperature 105°C). - Correction factor for bundle is not required.

cabletype

1H1.51H2.51H41H6

1H101H161H251H351H501H701H95

1H1201H1501H1851H240

(A)2838506487

115150184228279335385441500584

(A)33456076

104137179220272333400460526596697

(A)3243567196

127164200247300359411469530617

(A)33456076

104137179220272333400460526596697

(A)40547089

120157204248304370441505565629704

(A)33456076

104137179220272333400460526596697

Table I/2

triplet cables in

air

laid side by side cables in air

horizontal spaced cables in air

vertical spaced cables in air

laid cables in air, fixed on wall or

ceiling

triplet cables in air, fixed

on wall or ceiling

(A)35476178

105137178216266323385441498557624

(A)3142557096

127166203251307369424485550643

(A)3041536791

119154187230280334383435492572

(A)2635475981

107140171212260312359410465544

13-1415-16 *

13-1415-16 *

1415-16 *

1415-16 *

1111A *

1111A *

3 cables 2 cables 3 cables 2 cables 3 cables 2 cables 3 cables 2 cables 3 cables 3 cables

nominal conductor

cross section

mm2 2 cables

(A)

263546

2635475981

107140

283851

3242557096

127166

multi-core H (750 V) e L (500 V) M.I.C. bare, not exposed to touch (metal sheath maximum temperature 105°C). Correction factor for bundle is not required

cable in air, spaced from wall or ceiling or on platform

243344

2635475981

107140

500 V1.52.54

750 V1.52.546

101625

Table II/2

cable in air, fixed on wall or ceiling

3-14-15-16 * 11-11A *

314154

33456076

104137179

3 cables

(A)

2 cables

(A)

3 cables

(A)serie

* Installation methods taken from 3rd edition of CEI 64-8/5 norm, table 52 C

24

Page 21: English Brochure Mico_final

Table III Correction factor k1 for room temperature different from 30° C

room temperature

°C10152025

35404550

55606570

75808590

95

bare cable or covered by ther-moplastic material exposed to

touch

bare cable not exposed to touch

70 °C1.261.201.141.07

0.930.850.760.67

0.570.45

--

----

-

105 °C1.141.111.071.04

0.960.920.880.84

0.800.750.700.65

0.600.540.470.40

0.32

Nominal copper sheath resistance (Ω/km)RatedVoltage

Cross-Sectionmm2

500 V

750 V

11.52.54

1.52.546

10162535507095

120150185240300400

1 cond

2.9812.6772.2381.9311.6141.3101.0160.8520.6970.5580.4700.4050.3480.3000.2480.2040.163

2 cond2.8552.4221.8331.4191.3811.1840.9790.8240.6450.5050.397

3 cond2.2791.9311.614

1.2661.0680.8920.7460.5690.4530.364

4 cond1.9641.6891.344

1.0930.9340.7530.6450.5020.3880.308

7 cond1.4911.2930.990

0.8320.697

12 cond

0.5410.458

19 cond

0.414

Nominal copper sheath resistance

25

Page 22: English Brochure Mico_final

Mineral insulated cable TWISTED - code:2T1.5

Numbers of conductors 2 x 1.5 mm²

Insulation (MgO)

Diameter over copper sheath (5.7 mm)

Red LSF additional sheath (7.2 mm)

In 100 mtrs coils

Voltage rating

Conductors resistance (max.)

Nominal sheath resistance (screen)

Nominal capacitance conductor to conductor

Nominal capacitance one conductor to sheath at 1 kHz

Nominal capacitance between conductorsand copper sheath at 1 kHz

Nominal inductance (loop) at 10 MHz

Attenuation at 1 MHz

Attenuation at 10 MHz

Nominal chatacteristic impedance

Manufatured following the requirements of BS 6207

On request KME is able to produce twisted cables 2T1 and 2T2.5 and also shielded MI cables with double insulation

Dimensional characteristics

Electric characteristics

1

2

3

4

500 V

12.1 ohm/km

2.7 ohm/km

164.5 pF/m

243.5 pF/m

384.4 pF/m

436.0 μH/m

- 19.0 dB/km

- 52.0 dB/km

50 ohm

● Building management systems● Fire detection systems● Closed circuit television● Fire telephone systems● Data networks

26

1

2

3

4

Page 23: English Brochure Mico_final

KME Italy S.p.A.MICO® assembled and tested in factory - complete pieces

CONTROLStep 1: Customer receives complete pieces,only to be controlled (500 V, Riso > 500 MOhm)

FIXINGStep 2: Customer fixes cable on the wall

CONNECTIONStep 3: Customer joints conductors inside the junction box

Complete InstallationUsing this option:- Assembling and fixing is speeder- Customer saves time, avoiding termination time- KME quality and guarantee is assured

Power supplyJunction box

Switch/socket

Lamp

Fixing clips

Mico® cable 2L1.5

27

Page 24: English Brochure Mico_final

MICO®

PLAIN SEALS

It’s original MICO® termination type, characterised by minimum volume and minimum cost and execution time.Since it doesn’t foresee the connection of outer copper sheath, inside the junction box, to the earth system, it’s frequently used in public lighting to connect to double insulated lights and, for industrial applications in explosion-proof installation, within EEx d brass RAD ISO glands.

EARTH TAIL SEALSCopper outer sheath can be directly connected to earth system inside junction box by an annealed wire, already welded on brass pot.Also metallic junction box is connected as well by mechanical connection to outer sheath by brass glands, tightened through a locknut. Earth tail seals can so avoid an unpleasant outer earth connection.A correct execution of earth connection is extremely important for MICO® system, more than all other standard cables, since MICO® is the only cable to be installed at sight, exposed directly to touch also under 2.5 m of height, due to its structural mechanical resistance.

Gland bodyCompression ring

Backnut

MICO® Cable

Gland

Stub capBrass pot

Seal

Sleeving

TIPICAL CONNECTION

28

Inside Junction boxes or enclosures, using standard hubs, MICO system is connected t ostandard wiring system. Earth tail seal and brass gland (by mechanical connection to metal enclosures) assure perfect connection to earth/ground system. MICO brass glands are IP67 waterproof approved.

Page 25: English Brochure Mico_final

KME Italy S.p.A.FIXING SYSTEMS

Polyolefin extruded protection on the cable, available in red, orange, white and black colour, is required when:● There are aggressive substances and therefore there’s danger for corrosion. Typical LSF cables usage is in chemical, pharmaceutics and oil industries.● Specific colour must identify the circuit type, like, for instance, LSF red to identify all cables part of fire detection systems● Specific LSF colour is considered as the best solution for cable camouflage.

LSF COVERED CABLE

TOOLS1

2

3 4

5

678

9

10

11

1) Small bender lever ZBLS (10 mm < Ø <16 mm)

2) Large bender lever ZBLL (Ø >16 mm)

3) Large ringer ZRL

4) Small rotary stripper (for 2L1 and 2L1.5 cables) ZSUS

5) Spare blade for small stripper ZSUSB

6) Crimping tool for G – M20 seals ZDC20

7) Crimping tool for J/K – M25/32 seals ZDC25 8) Plate type crimper for M – M40 seals ZDD 40

9) Large universal stripper ZSU

10) Spare blade for large stripper ZSUB 11) Straightener ZBSS (Ø <10 mm)

29

Page 26: English Brochure Mico_final

MICO®

JUNCTION BOXES

BRASS line COPPER line

30

In order to complete MICO® system range, KME produces also 2 ranges of valuable metal junction boxes: in sandblasted brass and in copper. The first one is manufactured after melting, the second through assembly and welding of semi-finished products coming from KME divisions standard production.Production dimensions for junction boxes are:83 x 117 x 63 mm (small type) in our stock both for brass and copper; 132 x 191 x 72 mm (large type) in stock only for brass. Copper junction boxes can be manufactured according to any desired dimension by the Customer. All junction boxes can be supplied with a holed panel, so to install behind it all series of mounting frames and relative switches and sockets.

Page 27: English Brochure Mico_final

KME Italy S.p.A.WATERPROOF STRAIGHT THROUGH JOINT

31

cable type cable type cable typeL L L

2L12L1.52L2.52L43L1

3L1.53L2.54L1

4L1.54L2.57L1

7L1.57L2.5

2H1.52H2.52H42H6

2H102H162H253H1.53H2.53H43H6

3H103H16

3H254H1.54H2.54H44H6

4H104H164H257H1.57H2.5

12H1.512H2.519H1.5

50505050505050505050707070

50505050707080505050707070

100505070707080

10070707080

100

L L

Gland GlandFerrules Insulating sleeving

KME speedseal (minimum 3 wrappings)

Brass tube

Page 28: English Brochure Mico_final

REFERENCE LIST

Indoor lighting

HYSTORICAL AREAS

Outdoor lighting

VISCONTI CASTLE – PAVIA (14th century)Designer: Arch. Stefano Vassallo

Clerk of works: Arch. Vittorio PrinaPublic buildings office – town of Pavia

Main contractor: IGET – Palestrina (Rome)

ROCCA MAGGIORE & MINORE– ASSISI (12th century)Designer: Arch. Barabani

Clerk of works: Ing. CristianoTechnical office Manager – town of Assisi

Main contractor: VEBE of Belli Gianluca (PG)

CATHEDRAL SQUARE, POPE PALACE AND FARNESE FAMILY PALACE (12th 13th and century)Clerk of works: C.E.V. Spa di ViterboMain contractor: Morelli Giorgio – Viterbo

CATHEDRAL AREA OF SIENA12th centuryTOWN WALLS CATHEDRAL MUSEUM

Designer: Leonardo P.I. GozziMain contractor: Cesare Mazzini

CISTERCENSE ABBEY OF SAN GALGANO (SI)Main contractor: Mannelli SpA - Florence

32

Page 29: English Brochure Mico_final

KME Italy S.p.A.

Archaeological Areas

INDUSTRIAL AREA Emergency and safety circuits

Public lighting of town streets

RICCO’ CARLO & FRATELLI (s.p.a.) Rhesins and paintings factory – Correggio (RE) - Designer: Studio EMMECI consultants by Marzi Enrico

HYSTORICAL CENTRE OF TAORMINA (ME)Designer and Clerk of works: Ing. Carmelo De Caromain contractor: COGIP Srl (CT) - installation made by: Savoca and Scollo Company

TRAIANO FORUM (Rome) – 2nd century ACDesigner and Clerk of works: ACEA SpA (Rome) - Ing. Stefano Santia - Main contractor: Prudenzi Mario

33

Page 30: English Brochure Mico_final

34

REFERENCE LIST-ASIA

Using KME Italy MICC Cable in Hong Kong, China & MacauProjects in Hong Kong

Hospital:- QUEEN ELIZABETH HOSPITAL - A.O. B.D.D.- REDEVELOPMENT OF RUTTONJEE SANATORIUM HOSPITAL - J.R.P.- PAMELA YOUDE HOSPITAL - A.C.E.

Industrial Plant/Factory- TUEN MUN COLD STORAGE - Richard Chan & Associate- SWIRE DURO FACTORY - Tomas & Anderson- SAI KUNG CHINA PAINTING FACTORY - David Wu & Consolidate Consultan Engineers- ON LOK TELEPHONE EXCHANGE BUILDING - J.R.P.- H.K. STANDARD NEWSPAPER INDUSTRIAL FACTORY - Eric Leung Architect & Engineering Associate - SWIRE MAGNETIC FACTORY - Thomas & Anderson- M.C. PACKAGING FCTORY - Lu & Associates- TAI PO PRINTING FACTORY - P&T- ORIENTA DAILY NEWS BUILDING - A. Thomas- YAM O DOCKYARD- CLP CASTLE PEAK POWER STATION- TIN SHUI WAI LOT 7- DORSET HOUSE

Projects in Hong Kong-Cont’d

Office Buildings/School- CHAI WAN TECHNICAL INSTITUTE - J.R.P- SEAMEN TRAINING CENTRE - Kennedy & Donkin- CITY POLYTECHNIC PHASE I - A.C.E.- HARBIUR ROAD LOT 19 GOVERNMENT OFFICE BUILDING - A.O. B.D.D.- PACIFICPLACE PHASE I & II - Wong& Ouyang- TSIMSHATSUI CULTURAL COMPLE - A.O. B.D.D.- HOUSING HEADQUARTERS - J.R.P. - LDC PROJECT H6- LEE GARDEN REDEVELOPMENT

Tunnels/Depots- MONGKOK RAILWAY STATION - A.O B.D.D.- ROYAL HONG KONG JOCKEY CLUB GRAND STAND - O.A.P.- LRT-TUEN MUN DEPOT - P.B.A.- EASTERN HARBOUR CROSSING TUNNEL - Freeman Fox

Residental Buildings/Public Entertainment Centres- WHAMPOA SITE 5 - A.C.E.- WHAMPOA SITE 5 & 6 - Wong & Ouyang

Airport Projects- HACTL SUPERTERMINAL1

Projects in China

- SILVER BAY II IN PRC JOHN - Cornell- GUILIN CHINA HOTEL IN PRC - P.B.A.- XIAN XIDU HOTEL IN PRC - P.B.A.- SKY CENTRAL PLAZA - P.B.A.

Projects in Macau

- CEM BUIDING - P.B.A.- NAM YUEN BUIDING - Nam Kwong

Page 31: English Brochure Mico_final

35

KME Italy S.p.A.

APPROVALS

MICO® fire resistant cableis approved according:IEC 60331 - 3 hours - 750°CLPCB 6387 - 3 hours 950°C + mechanical and water testAS/NZS 3113 - 2 hours up to1050°C + mrechanical tests

LSF outer sheath approvals:low smoke emission,flame retardant

KME accessories are ATEXapproved for Ex d protection

Page 32: English Brochure Mico_final

KME Italy S.p.A.

Manufacturing plant and sales office:KME Italy S.p.A.Via della Repubblica, 25755051 Fornaci di Barga (LU)

Sales Assistance: ph. +39 0583 701412fax + 39 0583 701410technical assistance:ph. +39 0583 701412fax +39 0583 [email protected]