Istanbul Technical University Energy Institute Energy Science & Technology EBT 530E Energy Efficient Building Design Spring Semester 2015 Case Study CASE STUDY ON A TYPICAL VILLAGE HOUSE IN SAPANCA/DİBEKTAŞ DISTRICT Cem LALE 1 301961010 ABSTRACT In this Case Study, We will extract previous work, which includes an analysis of a Sample House located in Sapanca/Dibektaş village. In the first section you will see geographical orientation of the house, using Google Earth, upcoming sections there will be statistics about Annual Climate Characteristics of the region and Temperature Graphs can be seen . The Climate type of the region is CFa, Altitude : 40Mt., Average Annual Temp: 14,3C, Average Rainfall : 740 mm. Upcoming Sections there will be Simulation program trials on E-Quest and first two simıulations because of missing input data, such as not possible to upload local Climate conditions, not selected Electric & Gas Company, there was a limited output can be seen according to limited inputs. Additionally in this Case study, we tried to locate similar charecteristics especially around 40 th parallel in US. We have found some candidate cities such as Pittsburg, but since the rainfall characteristic and other specifications is not matched it did not reflect %100 precise information. Howewer we made a second work to understand output accordingly. Regarding E Quest, we used 3 design wizard Scenarios , and dimensions of the building can be seen realistic in upcoming sections. On the other hand, since we have limited options during the selection of the insulation material, roof etc. parameters will not reflect %100 our sample and simple village house. Although we’ve got some idea to focus on material usage on the house, since we have options to concrete and wood. In the 2 nd . Simulation we had a chance to observe some outputs which helped us to understand deeper information about E-Quest Program. In the 3 rd simulation, we’ve used only local conditions files, cooling and heating loads of the chosen building for two different Wall Material selection. 1 Istanbul Technical University, Energy Institute, Energy Science & Technology, EBT 530E Energy Efficient Building Design
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Istanbul Technical University Energy Institute Energy Science & Technology
EBT 530E Energy Efficient Building Design Spring Semester 2015
Case Study
CASE STUDY ON A TYPICAL VILLAGE HOUSE IN
SAPANCA/DİBEKTAŞ DISTRICT
Cem LALE
1301961010
ABSTRACT
In this Case Study, We will extract previous work, which includes an analysis of a Sample House
located in Sapanca/Dibektaş village. In the first section you will see geographical orientation of the
house, using Google Earth, upcoming sections there will be statistics about Annual Climate
Characteristics of the region and Temperature Graphs can be seen . The Climate type of the region is
CFa, Altitude : 40Mt., Average Annual Temp: 14,3C, Average Rainfall : 740 mm. Upcoming Sections
there will be Simulation program trials on E-Quest and first two simıulations because of missing
input data, such as not possible to upload local Climate conditions, not selected Electric & Gas
Company, there was a limited output can be seen according to limited inputs. Additionally in this
Case study, we tried to locate similar charecteristics especially around 40th parallel in US. We have
found some candidate cities such as Pittsburg, but since the rainfall characteristic and other
specifications is not matched it did not reflect %100 precise information. Howewer we made a
second work to understand output accordingly.
Regarding E Quest, we used 3 design wizard Scenarios , and dimensions of the building can be seen
realistic in upcoming sections. On the other hand, since we have limited options during the selection
of the insulation material, roof etc. parameters will not reflect %100 our sample and simple village
house. Although we’ve got some idea to focus on material usage on the house, since we have options
to concrete and wood.
In the 2nd. Simulation we had a chance to observe some outputs which helped us to understand deeper
information about E-Quest Program.
In the 3rd simulation, we’ve used only local conditions files, cooling and heating loads of the chosen
building for two different Wall Material selection.
1 Istanbul Technical University, Energy Institute, Energy Science & Technology, EBT 530E Energy Efficient
Building Design
2
TABLE OF CONTENTS
1. INTRODUCTION Page 3 2. GEOGRAPHICAL DATA Page 4
3. CLIMATE Page 5
4. E-QUEST ANALYSIS SIMULATION-1 Page 6
5. E-QUEST ANALYSIS SIMULATION-2 Page 22
6. E-QUEST ANALYSIS SIMULATION-3 Page 41
7. CONLUSION Page 47
8. REFERENCES Page 50
3
1. INTRODUCTION
In our mid Term Report, we were studying on a Simple Village House located
near Sapanca Lake, Turkey. In the study basic construction information about this
building was given.
This Study is continuing to work on the Same Area/Building, next Section we’ve
added detailed Climatical information, Temperature graphs and rainfall
analysis,annually.
Also we will make three simulations for similar Structured Buildings which is
created on E-quest, and Compare their Design Wizard Steps.
Our Aim is understand the program capabilities, reportings and how we can get
help using defined design parameters, not only dimensions or Climate Data also
how we can use predefined and standardized information before decide to make
some work in our houses, or Business place.
In the last section, we used only Cad drawing of the House, and used Sapanca
Original Climate files which is directly imported to the E-Quest program,
followings steps we calculated “U” values of the building according to TS825.
And in conclusion part, we managed to compare two different materials in the
same conditions to understand differences in terms of Cooling & Heating analysis.
4
2. GEOGRAPHICAL DATA
As seen in Figure 1. The House has coordinates in below map.
Figure1. Source Google Maps
Figure 2. Satellitewiew: The Building is in the red circle. Source: Google Earth
5
3. CLIMATE
Regarding Climate data, additionally general information which was given in the first
report, here below Annual Climate Graph of Sapanca,