Top Banner
Application Note EDG0108TN001 Enabler II-E Engineering Mode Command Reference Revision 1.00
22

Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

Mar 31, 2018

Download

Documents

duongkhanh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

Application Note EDG0108TN001

Enabler II-E Engineering Mode Command Reference

Revision 1.00

Page 2: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

Copyright Statement Copyright 2007 by Enfora, Inc. All rights reserved. No portion of this document may be copied, photocopied, reproduced, transmitted, transcribed, stored in a retrieval system or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of Enfora, Inc. © 2007 Enfora, Inc. All rights reserved. Disclaimer Enfora, Inc. makes no representations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties, merchantability or fitness for any particular purpose. Further, Enfora, Inc. reserves the right to revise this publication, and to make changes from time to time in the contents hereof without obligation of Enfora, Inc. to notify any person of such revision or changes. ALL INFORMATION IS PROVIDED BY ENFORA, INC. ON AN “AS IS” BASIS ONLY. THIS COMPANY PROVIDES NO REPRESENTATIONS AND WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY AND NONINFRINGEMENT. All product names mentioned within this document are the trademark of their respective owners. Enfora, Inc. Proprietary Information EDG0108TN001 Adobe® Acrobat Reader, © 1987-1999 Adobe Systems Inc. All rights reserved. Adobe and Acrobat are trademarks of Adobe Systems Inc.

Page 3: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

Table of Contents Introduction ..................................................................................................................... 1 AT%EM=2,1 Serving Cell Information........................................................................ 2 AT%EM=2,2 Serving Cell GPRS Information ............................................................ 3 AT%EM=2,3 Neighbor Cell Information ..................................................................... 4 AT%EM=2,3 Neighbor Cell Information ..................................................................... 5 AT%EM=2,4 Location and Paging Parameters.......................................................... 6 AT%EM=2,5 PLMN Parameters ................................................................................ 7 AT%EM=2,6 Ciphering, Hopping, DTX Parameters................................................... 8 AT%EM=2,6 Ciphering, Hopping, DTX Parameters................................................... 9 AT%EM=2,7 Power Parameters .............................................................................. 10 AT%EM=2,7 Power Parameters .............................................................................. 11 AT%EM=2,8 Identity Parameters............................................................................. 12 AT%EM=2,8 Identity Parameters............................................................................. 13 AT%EM=2,10 GMM Information ................................................................................ 14 AT%EM=2,11 GRLC Information ............................................................................... 15 AT%EM=2,12 AMR Configuration Information........................................................... 16 AT%EM=2,13 PDP Information.................................................................................. 17 AT%EM=2,14 Throughput Information....................................................................... 18

Table of Figures Table 2.1 - Serving Cell Information................................................................................ 2 Table 2.2 - Serving Cell GPRS Information .................................................................... 3 Table 2.3 - Neighbor Cell Information ............................................................................. 5 Table 2.4 - Location and Paging Parameters.................................................................. 6 Table 2.5 - PLMN Parameters ........................................................................................ 7 Table 2.6 - Ciphering, Hopping, DTX Parameters........................................................... 9 Table 2.7 - Power Parameters ...................................................................................... 11 Table 2.8 - Identity Parameters..................................................................................... 12 Table 2.8.1 - How to Read %EM=2,8 Output Example................................................. 13 Table 2.10 - GMM Information ...................................................................................... 14 Table 2.11 - GRLC Information..................................................................................... 15 Table 2.12 - AMR Configuration Information................................................................. 16 Table 2.13 - PDP Information ....................................................................................... 17 Table 2.14 - Throughput Information............................................................................. 18

Page 4: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 1 Copyright, 2007 Enfora, Inc.

Engineering Mode Parameters -- %EM: Introduction This document contains the functional interface description for the engineering mode driver. The purpose of Engineering Mode (EM) is to provide means to observe the behavior of the mobile station and the settings of the network as counterpart and therefore defines a lot of possibilities to analyze the network. The EM can be used for observation of a defined data set during functional test and field test. To get the data it is necessary to insert “AT-Commands”. This can be done via a terminal program such as HyperTerminal or ProComm. The commands are as follows:

• AT%EM=2,1 Serving Cell Information • AT%EM=2,2 Serving Cell GPRS Information • AT%EM=2,3 Neighbour Cell Information • AT%EM=2,4 Location and Paging Parameters • AT%EM=2,5 PLMN Parameters • AT%EM=2,6 Ciphering, Hopping, DTX Parameters • AT%EM=2,7 Power Parameters • AT%EM=2,8 Identity Parameters • AT%EM=2,10 GMM Information • AT%EM=2,11 GRLC Information • AT%EM=2,12 AMR Configuration Information • AT%EM=2,13 PDP Information • AT%EM=2,14 Throughput Information

!

The display of certain parameters is dependent on the wireless network sending the correct information in the System Information Packets. There is no guaranty that the information is always forwarded from the network. At times data may not be present to display in the Engineering Mode responses.

Page 5: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 2 Copyright, 2007 Enfora, Inc.

AT%EM=2,1 Serving Cell Information AT Command Entered:

AT%EM=2,1 Response Format:

%EM: afrcn, c1, c2, rxlev, bsic, cell_id, dsc, txlev, tn, rlt, tav, rxlev_f, rxlev_s, rxqual_f, rxqual_s, lac, cba, cbq, cell_type_ind, vocoder

Example:

AT%EM=2,1 %EM: 581,8,8,6,40,1221,23,0,1,0,0,0,0,0,0,42126,0,0,2,255 OK

Defined Values:

Table 2.1 - Serving Cell Information Parameter Number Short Name Parameter Remarks

1 arfcn Current Channel Number 2 c1 Path Loss Criterion C1 3 c2 Cell-reselection Criterion C2 4 rxlev Received Field Strength (rxlev/2)+2= AT+CSQ

response value 5 bsic Base Station ID Code 6 cell_id Cell Indentifier 7 dsc Downlink Signaling Counter actual value 8 txlev Transmit Power Level 9 tn Timeslot Number 10 rlt Radio Link Timeout Counter 11 tav Timing Advance 12 rxlev_f Received Field Strength full 13 rxlev_s Received Field Strength sub 14 rxqual_f Received Quality full 15 rxqual_s Received Quality sub 16 lac Location Area Code 17 cba Cell Bar Access 18 cbq Cell Bar Qualifier 19 Cell_type_ind Cell Type Indicator NA/GSM/GPRS 20 vocoder Vocoder Sig/speech/efr/amr/14.4

/9.6/4.8/2.4

Page 6: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 3 Copyright, 2007 Enfora, Inc.

AT%EM=2,2 Serving Cell GPRS Information AT Command Entered:

AT%EM=2,2 Response Format:

%EM: nts, nmo, spgc_ccch_sup, priority_access_thr, cba, rac, tav, dsc, c31, c32, nco Example:

AT%EM=2,2 %EM: 238,1,0,6,0,1,255,0,0,0,255,0,0,0,1,1,5,0

OK

Defined Values:

Table 2.2 - Serving Cell GPRS Information Parameter Number Short Name Parameter Remarks

1 nts PCCCH_TIMESLOT Number of downlink timeslots

2 nmo Network Mode of Operation 3 spgc_ccch_sup Network Control-spgc_ccch_sup Network support

of split paging 4 priority_access_thr Network Control-

Priority_Access_Threshold packet access to the NW according priority level

5 cba Cell Bar Access 6 rac Routing Area Code 7 tav Timing Advance 8 dsc Downlink Signal Counter 9 c31 Cell-reselect Criterion C31 10 c32 Cell-reselect Criterion C32 11 band_ind Band Indicator 12 pfc_supp_n_w PFC Support 13 ccn_mode_sts CCN Mode 14 Psi_sts_suppt PSI Support 15 edge_support EDGE Support 16 epcr_support EPCR Support 17 bep_period BEP Period 18 bss_paging_coord BSS Paging

Page 7: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 4 Copyright, 2007 Enfora, Inc.

AT%EM=2,3 Neighbor Cell Information AT Command Entered:

AT%EM=2,3 Response Format:

(cell0, cell1, cell2, cell3, cell4, cell5)

%EM: no_ncells afrcn_nc[0], afrcn_nc[1], afrcn_nc[2], afrcn_nc[3], afrcn_nc[4], afrcn_nc[5] c1_nc[0], c1_nc[1], c1_nc[2], c1_nc[3], c1_nc[4], c1_nc[5] c2_nc[0], c2_nc[1], c2_nc[2], c2_nc[3], c2_nc[4], c2_nc[5] rxlev_nc[0], rxlev_nc[1], rxlev_nc[2], rxlev_nc[3], rxlev_nc[4], rxlev_nc[5] bsic_nc[0], bsic_nc[1], bsic_nc[2], bsic_nc[3], bsic_nc[4], bsic_nc[5] cell_id_nc[0], cell_id_nc[1], cell_id_nc[2], cell_id_nc[3], cell_id_nc[4], cell_id_nc[5] lac_nc[0], lac_nc[1], lac_nc[2], lac_nc[3], lac_nc[4], lac_nc[5] frame_offset[0], frame_offset[1], frame_offset[2], frame_offset[3], frame_offset[4],

frame_offset[5] time-alignmnt[0], time-alignmnt[1], time-alignmnt[2], time-alignmnt[3], time-alignmnt[4],

time-alignmnt[5] cba_nc[0], cba_nc[1], cba_nc[2], cba_nc, cba_nc[4], cba_nc[5] cbq_nc[0], cbq_nc[1], cbq_nc[2], cbq_nc[3], cbq_nc[4], cbq_nc[5] cell_type_ind[0], cell_type_ind[1], cell_type_ind[2], cell_type_ind[3], cell_type_ind[4],

cell_type_ind[5] rac[0], rac[1], rac[2], rac[3], rac[4], rac[5] cell_resel_offset[0], cell_resel_offset[1], cell_resel_offset[2], cell_resel_offset[3],

cell_resel_offset[4], cell_resel_offset[5] temp_offset[0], temp_offset[1], temp_offset[2], temp_offset[3], temp_offset[4],

temp_offset[5] rxlev_acc_min[0], rxlev_acc_min[1], rxlev_acc_min[2], rxlev_acc_min[3],

rxlev_acc_min[4], rxlev_acc_min[5] Example:

AT%EM=2,3 %EM: 6 165,170,598,601,605,163 24,35,17,15,17,24 26,43,17,15,17,24 26,33,15,13,15,22 5,9,42,21,43,53 51298,8825,0,8821,0,15572 5227,5232,5227,5232,5232,55024 1478721,1062786,0,1062428,0,0 2472,1556,0,3796,4,4 0,0,0,0,0,0 0,0,0,0,0,0 2,2,2,2,2,2 0,0,0,0,0,0 1,4,0,0,0,0 0,0,0,0,0,0 4,0,0,0,0,0 OK

Page 8: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 5 Copyright, 2007 Enfora, Inc.

AT%EM=2,3 Neighbor Cell Information Defined Values:

Table 2.3 - Neighbor Cell Information Parameter Number Short Name Parameter Addition

Parameters

1 no_ncells Number of neighbor cells 2 arfcn_nc BCCH channel Channel no 0 - 5 3 c1_nc Path Loss Criterion C1 Channel no 0 - 5 4 c2_nc Cell-Reselection Criterion C2 Channel no 0 - 5 5 rxlev_nc Receive Field Strength Channel no 0 - 5 6 bsic_nc Base Station ID Code Channel no 0 - 5 7 cell_id_nc Cell Identity Channel no 0 - 5 8 lac_nc Location Area Code Channel no 0 - 5 9 frame_offset Frame Offset Channel no 0 - 5 10 time-alignmnt Time Alignment Channel no 0 - 5 11 cba_nc Cell Bar Access Channel no 0 - 5 12 cbq_nc Cell Bar Qualifier Channel no 0 - 5 13 cell_type_ind Cell Type Indicator Channel no 0 - 5 14 rac Routing Area Code Channel no 0 - 5 15 cell_resel_offset Cell resection Offset Channel no 0 - 5 16 temp_offset Temporary Offset Channel no 0 - 5 17 rxlev_acc_min Rxlev access min Channel no 0 - 5

Page 9: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 6 Copyright, 2007 Enfora, Inc.

AT%EM=2,4 Location and Paging Parameters AT Command Entered: AT%EM=2,4 Response Format:

%EM: bs_pa_mfrms, t3212, mcc[0] mcc[1] mcc[2], mnc[0] mnc[1] mnc[2], tmsi Example:

AT%EM=2,4 %EM: 4,9,310,380,1034577220

OK

Defined Values:

Table 2.4 - Location and Paging Parameters Parameter Number Short Name Parameter Remarks

1 bs_pa_mfrms BS PA MFRMS paging repeat period 2 t3212 Periodic location updating interval 3 mcc Mobile Country Code 4 mnc Mobile Network Code 5 tmsi Temporary Mobile Subscriber Identity binary

representation

Page 10: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 7 Copyright, 2007 Enfora, Inc.

AT%EM=2,5 PLMN Parameters AT Command Entered:

AT%EM=2,5 Response Format:

%EM: no_creq_max, reest_flag, txpwr_max, rxlev_min, rel_cs Example:

AT%EM2,5 %EM: 3,1,0,2,0,2,1,2

OK

Defined Values:

Table 2.5 - PLMN Parameters Parameter Number Short Name Parameter Remarks

1 no_creq_max Max. number or retries for channel requests

2 reest_flag Re-establishment Flag 3 txpwr_max MS TXPWR MAX CCCH 4 rxlev_min Rxlev_access_min 5 rel_cs Release Cause The last release

cause is stored 6 sgsnr_rel SGSNR Release

7 mscr_rel MSCR Release

8 net_rel Network Release Info

Page 11: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 8 Copyright, 2007 Enfora, Inc.

AT%EM=2,6 Ciphering, Hopping, DTX Parameters Note: This configuration information is only valid in case of an active call. Only dtx_stat parameter

will be valid in IDLE state. AT Command Entered:

AT%EM=2,6 Response Format: %EM: ciph_stat, hop, arfcn, hsn, dtx_stat, v_start maio, nr_arfcns (get displayed only if hop==1) ma maio, nr_arfcns (get displayed only if v_start==1) ma Example: Idle: AT%EM=2,6 %EM: 0,0,0,0,1,0 OK Dedicated: 1. Hoping is not configured AT%EM=2,6 %EM: 0,0,0,0,1,0 OK 2. Hopping is configured AT%EM=2,6 %EM: 0,1,0,40,1,0 10,17 537,538,539,540,541,542,543,544,545,546,547,548,549,550,551,552,553 OK 3. Both hopping and starting time (v_start) are used AT%EM=2,6 %EM: 0,1,0,40,1,1 10,17 537,538,539,540,541,542,543,544,545,546,547,548,549,550,551,552,553 8,4 546,547,550,551

OK

Page 12: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 9 Copyright, 2007 Enfora, Inc.

AT%EM=2,6 Ciphering, Hopping, DTX Parameters Defined Values:

Table 2.6 - Ciphering, Hopping, DTX Parameters

Parameter Number Short Name Parameter Remarks

1 ciph_stat Cipher Status 2 hop Hopping Status H_NO/H_YES 3 arfcn Frequency of the configured

channel Valid if hop=H_NO

4 hsn Hopping Sequence Number Valid if hop=H_YES 5 hop_chn Hopping Channels 6 dtx_stat DTX Status 7 v_start Start Time Validity 8 hop_chn.maio Mobile Allocation Index Offset before time config 9 hop_chn.nr_arfcns Number of Hopping Channels before time config 10 Hop_chn.ma Hopping Channels before time config 11 hop_chn2.maio Mobile Allocation Index Offset after time.nr_arfcn 12 hop_chn2.nr_arfcns Number of Hopping Channels after time config 13 Hop_chn2.ma Hopping Channels after time.nr_arfcn

Page 13: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 10 Copyright, 2007 Enfora, Inc.

AT%EM=2,7 Power Parameters AT Command Entered:

AT%EM=2,7 Response Format: %EM: classmark2 classmark3 (See Defined Values Table 2.7 on the following page) Example:

AT%EM=2,7 %EM: 1,1,0,0,0,1,1,0,0,0,1,0 0,0,0,0,0,0,0,0,0,0,0,0,0,1,0,0,0,0 OK

Page 14: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 11 Copyright, 2007 Enfora, Inc.

AT%EM=2,7 Power Parameters Defined Values:

Table 2.7 - Power Parameters Parameter Number Short Name Parameter Remarks

classm2. Classmark2 1 rev_lev Revision Level 2 es_ind Controlled Early Classmark

Sending enabled (1) or not (0)

3 a5_1 Encryption algorithm A5/1 available (0) or not (1) 4 rf_pow_cap RF Power Capability 5 ps_cap Pseudo Synchronization

Capability present (1) or not (0)

6 ss_screen SS Screening Indicator 7 sm_cap Short Message Capability 8 freq_cap Frequency Capability 9 class_3 Classmark 3 options supported (1) or not (0) 10 cmsp CM Service Prompt supported (1) or not (0) 11 a5_3 Encryption algorithm A5/3 available (1) or not (0) 12 a5_2 Encryption algorithm A5/2 available (1) or not (0) classm3. Classmark3 1 mb_sub Multiband Support 2 a5_7 Encryption algorithm A5/7 available (1) or not (0) 3 a5_6 Encryption algorithm A5/6 available (1) or not (0) 4 a5_5 Encryption algorithm A5/5 available (1) or not (0) 5 a5_4 Encryption algorithm A5/4 available (1) or not (0) 6 v_radio_cap_2 valid-flag 7 radio_cap_2 Associated Radio Capability 2 8 v_radio_cap_1 valid-flag 9 radio_cap_1 Associated Radio Capability 1 10 v_r_support valid-flag 11 r_support R Support R-GSM Class 12 v_m_s_class valid-flag 13 m_s_class Multi Slot Class 14 ucs2_treat UCS2 treatment 15 ext_meas_cap Extended Measurement

Capability supported (1) or not (0)

16 v_meas_cap valid-flag 17 meas_cap.sw_time Switch-Measure-Value 18 meas_cap.sws_time Switch-Measure-Switch-Value

Page 15: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 12 Copyright, 2007 Enfora, Inc.

AT%EM=2,8 Identity Parameters AT Command Entered: AT%EM=2,8 Response Format: %EM: imeisv imsi tmsi Example: AT%EM=2,8 %EM: 3,0,1,16,3,5,3,2,6,8,0,0,0,0,6,4,4,4,1,0 1,1,1,15,3,1,0,3,8,0,0,4,7,3,9,8,2,3,6,255 1034577220 OK Note: Refer to Table 2.8.1 for an example on how to read the response output to the %EM=2,8 engineering mode command. Defined Values:

Table 2.8 - Identity Parameters Parameter Number Short Name Parameter Remarks

1 em_imeisv. IMEISV ident_type odd_even v_ident_dig c_ident_dig ident_dig[j] 14 digit IMEI ident_dig[15] 2 em_imsi. IMSI ident_type odd_even v_ident_dig c_ident_dig ident_dig[j] 16 digit IMSI ident_dig[15] 3 tmsi TMSI

Page 16: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 13 Copyright, 2007 Enfora, Inc.

AT%EM=2,8 Identity Parameters Response Output: %EM: 3,0,1,16,3,5,3,2,6,8,0,0,0,0,6,4,4,4,1,0 1,1,1,15,3,1,0,3,8,0,0,4,7,3,9,8,2,3,6,255 1034577220 OK

Table 2.8.1 - How to Read %EM=2,8 Output Example IMEISV Output: 3, 0, 1, 16, 3, 5, 3, 2, 6, 8, 0, 0, 0, 0, 6, 4, 4, 4, 1, 0

em_im

eisv.

em_im

eisv.

em_im

eisv.

em_im

eisv.

em_im

eisv.

em_im

eisv. ident_type

odd_even

v_ident_dig

c_ident_dig

(IME

I)

ident_dig[j]

ident_dig[15]

IMSI Output: 1, 1, 1, 15, 3, 1, 0, 3, 8, 0, 0, 4, 7, 3, 9, 8, 2, 3, 6, 255

em_im

si.

em_im

si.

em_im

si.

em_im

si.

em_im

si.

em_im

si. ident_type

odd_even

v_ident_dig

c_ident_dig

(IMS

I)

ident_dig[j]

ident_dig[15]

TMSI Output: 1 0 3 4 5 7 7 2 2 0

TMS

I

Page 17: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 14 Copyright, 2007 Enfora, Inc.

AT%EM=2,10 GMM Information AT Command Entered:

AT%EM=2,10 Response Format: %EM: ready_state, tlli, ptmsi, ptmsi_sig, ready_timer, ciphering_algorithm, T3312_deactivated, T3321_val Example:

AT%EM=2,10 %EM: 1,3671683092,3671683092,16777215,60000,1,0,3240

OK

Defined Values:

Table 2.10 - GMM Information Parameter Number Short Name Parameter Remarks

1 ready_state Ready-Standby State 2 tlli Temporary Logic Link Identifier 3 ptmsi Packet Temporary Mobile

subscriber Identity 4 ptmsi_sig P-TMSI Signature 5 ready_timer Timer READY Value 6 ciphering_algorithm Cipher Algorithm 7 T3312_deactivated T3312 Timer Status active/deactive 8 T3312_val T3312 Timer Value in seconds

Page 18: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 15 Copyright, 2007 Enfora, Inc.

AT%EM=2,11 GRLC Information AT Command Entered:

AT%EM=2,11 Response Format: %EM: grlc_state, tbf_mod, ul_tbf_par.tfi, ul_tbf_par.mac_mod, ul_tbf_par.ul_nb_block, ul_tbf_par.cv, ul_tbf_par.cs, dl_tbf_par.tfi, dl_tbf_par.mac_mod Example: AT%EM=2,11 %EM: 1,0,255,0,0,0,1,255,0 OK Defined Values:

Table 2.11 - GRLC Information Parameter Number Short Name Parameter Remarks

1 grlc_state GRLC status 0 TM_ACCESS_DISABLED 1 TM_PIM 2 TM_PAM 3 TM_PTM 4 TM_WAIT_4_PIM 2 tbf_mod TBF status 0 TBF_TYPE_NULL 1 TBF_TYPE_UL 2 TBF_TYPE_DL 3 TBF_TYPE_CONC (3-7) ul_tbf_par. Uplink TBF Parameter 3 tfi Temporary Flow

Identifier 4 mac_mode Allocation Type 5 ul_nb_block Number of Blocks to be

emitted 6 cv Countdown Value 7 cs Coding Scheme 0 CS_1 1 CS_2 2 CS_3 3 CS_4 (8-9) dl_tbf_par. Downlink TBF Parameter 8 tfi

Temporary Flow Identifier

9 mac_mode Allocation type

Page 19: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 16 Copyright, 2007 Enfora, Inc.

AT%EM=2,12 AMR Configuration Information Note: AMR configuration information is valid only in case of an active call when AMR is configured. AT Command Entered:

AT%EM=2,12 Response Format: %EM: amr_vocoder, amr_icmi, amr_icm, amr_acs, amr_first_codec, amr_nr_modes, amr_codec_thr1, amr_codec_hyst1, amr_codec_thr2, amr_codec_hyst2, amr_codec_thr3, amr_codec_hyst3 Example: Idle: AT%EM=2,12 %EM: 0,0,0,0,0,0,0,0,0,0,0,0 Dedicated: 1. AMR is not configured AT%EM=2,12 %EM: 0,0,0,0,0,0,0,0,0,0,0,0 2. AMR is configured AT%EM=2,12 %EM: 0,0,1,3,1,2,3,3,0,0,0,0 Defined Values:

Table 2.12 - AMR Configuration Information Parameter Number Short Name Parameter Remarks

1 Amr_vocoder AMR Vocoder State Sig/speech/efr/amr/ 14.4/9.6/4.8/2.4

2 icmi Initial Codec Code Indicator Imp/smf 3 icm Initial Codec Start Mode Valid if icmi=smf 4 acs Active Codec Set 5 amr_first_codec AMR Highest Bit Rate Codec 6 amr_nr_modes Number of AMR Codec

Modes 7 amr_cod_prop. AMR Codec Properties amr_codec_thr Number 0-2 amr_codec_hyst Number 0-2

Page 20: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 17 Copyright, 2007 Enfora, Inc.

AT%EM=2,13 PDP Information AT Command Entered:

AT%EM=2,13 Response Format: %EM: MAX_CID c_state, pdp_type, apn, allocated_pdp_addr Example: Idle: AT%EM=2,13 %EM: 6 2,IP,internet, OK Dedicated: AT%EM=2,13 %EM: 6 12, IP, internet, xxx.xxx.xxx.xxx (assigned IP address) OK Defined Values:

Table 2.13 - PDP Information

Parameter Number Short Name Parameter Remarks

1 MAX_CID Max. Number of PDP Contexts 2 c_state PDP Context State 3 pdp_type PDP Address Type 4 apn Access Point Name 5 allocated_pdp_addr PDP Address

Page 21: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 18 Copyright, 2007 Enfora, Inc.

AT%EM=2,14 Throughput Information AT Command Entered:

AT%EM=2,14 Response Format: %EM: ul_net,ul_gross,dl_net,dl_gross,dl_crc_errors Example: AT%EM=2,14 %EM: 9,108,54,78,0 OK Defined Values:

Table 2.14 - Throughput Information

Parameter Number Short Name Parameter Remarks

1 ul_net Net uplink octet count 2 ul_gross Gross uplink octet count 3 dl_net Net downlink octet count 4 dl_gross Gross downlink octet count 5 dl_crc_errors Downlink CRC error count

NOTE: All counters are reset each time this command is issued.

Page 22: Enabler II-E Engineering Mode Command Referencebuildhost.automated.it/...Enabler_II-E_Engineering_Mode_Manual.pdf · Enabler II-E Engineering Mode Command Reference ... c2, rxlev,

EDG0108TN001 – Engineering Mode Manual Page 19 Copyright, 2007 Enfora, Inc.

Revision History

Date Rev Author Description 1/24/2007 1.00 Diane O’Neil Initial Release.