OPENING TRANSMITTER WEL-200T WEL-200T WEL-200R WEL-200R EMX CLOSING TRANSMITTER RECEIVER GND OPEN ONLY NC OPEN ONLY 10K PHOTO CLS NC OPEN/CLS NC GND 12VDC OUT GND CLS ONLY 10K OPEN/CLS 10K 12VDC OUT UL SENSOR N.C. UL SENSOR 10K JP-2 10K Jumper JP-1 10K Jumper EXIT PWR ALARM POWER / SOLAR IN BATTERY INPUT OPENING CLOSING CLOSING OPENING ERD OBD PORT BLACK BOX PROGRAMMING SOLAR MODE PROGRAM MOTOR OVER LOAD ERD MOTOR OVER LOAD MAX OFF MAX SENSE MAX SENSE BATTERY BACKUP MODE ERD SENSITIVITY MOTION CONTROL OPEN GATE SPEED MAG LOCK UL ENTRAP PRIMARY/ SECONDARY LINK STOP CLOSE MOTOR INPUTS CLOSE TIMER MAGLOCK DELAY JOG BATTERY TEST INPUT ERROR BATTERY BATTERY IN USE REPLACE BATTERY LEAVE CLOSED LEAVE OPEN OPEN 1 TIME BATTERY VOLTAGE E F 1/2 RESET / MANUAL RELEASE ID PLUG LINK OK MODULE PORT MOTOR POSITION INPUTS SLIDER LIMIT SWING LIMIT GND OPEN ONLY NC OPEN ONLY 10K PHOTO CLS NC OPEN/CLS NC GND 12VDC OUT GND GND GND GND GND GND JOG RIGHT JOG LEFT TAMPER IN TAMPER NO GATE DISABLE MANUAL RELEASE KEYPAD / CARD GND (-) (+) GND GND MAX OPEN FIRE DEPT RADIO GND RADIO SIGNAL STRIKE CLOSE COM COM STOP OPEN CLS ONLY 10K OPEN/CLS 10K 12VDC OUT NO COM NC ID PLUG ERROR 24VDC OUTPUT 12VDC OUTPUT GND GND GND LOOP PWR OFF PRIMARY LEFT ON/OFF BATTERY RIGHT SECONDARY ON QUICK OPEN LEFT OPEN RIGHT GATE OFF 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 MIN MIN MAX MAX ON OFF 2.5 sec 1.5 sec FAULTS OPERATOR MATRIX III OFF OFF 3 1 14 16 MIN 16 MIN 12 9 7 3 1 14 12 9 7 UL SENSOR N.C. UL SENSOR 10K POWER EXIT LOOP LOOP LOOP CENTER SAFETY GATE OPEN COM GATE CLOSED MIN MATRIX III SWING / SLIDE www.max.us.com EMX WEL-200 Wiring Guide FOR MAX PRO SERIES WIRE WEL-200R OPEN & CLOSE RELAYS TO MATRIX III 10K SENSOR INPUTS WIRE TO ‘NO’ OF RELAY OPEN WIRE TO ‘NO’ OF RELAY CLOSE 1 INSERT BOTH JUMPERS IN 10K POSITION 2 Polarity does NOT matter for power
2
Embed
EMX WEL-200 Wiring Guide FOR MAX PRO SERIES · photo cls nc open/cls nc gnd 12vdc out gnd cls only 10k open/cls 10k 12vdc out ul sensor n.c. ul sensor 10k p jp-2 10k jumpe r jp-1
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
OPENINGTRANSMITTER
WEL-200T WEL-200T
WEL-200R
WEL-200REMX
CLOSINGTRANSMITTER
RECEIVER
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN/CLS NC
GND
12VDC OUT
GND
CLS ONLY 10K
OPEN/CLS 10K
12VDC OUT
UL S
ENSO
R N.
C.UL
SEN
SOR
10K
PPPP
JP-210K
Jumper
JP-110K
Jumper
EXIT PWR
ALARM
POWER /SOLAR IN
BATTERYINPUT
OPENING CLOSING
CLOSINGOPENING
ERD
OBD PORTBLACK BOX
PROGRAMMING
SOLAR MODE
PROGRAM
MOTOROVERLOAD
ERD
MOTOROVERLOAD MAX
OFF
MAXSENSE
MAXSENSE
BATTERYBACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
GATE SPEED
MAGLOCK
ULENTRAP
PRIMARY/SECONDARY
LINK
STOP CLOSE
MOTORINPUTS
CLOSETIMER
MAGLOCKDELAY
JOG
BATTERYTEST
INPUTERROR
BATTERY
BATTERYIN USE
REPLACEBATTERY LEAVE
CLOSED
LEAVEOPEN
OPEN1 TIME
BATTERY VOLTAGEE F1/2
RESET /MANUALRELEASE
IDPLUG
LINKOK
MODULEPORT
MOTORPOSITIONINPUTS
SLIDERLIMIT
SWINGLIMIT
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NCOPEN/CLS NC
GND12VDC OUT
GND
GND
GND
GND
GND
GND
JOG
RIGH
TJO
G LE
FT
TAMP
ER IN
TAMP
ER N
O
GATE
DISA
BLE
MANU
AL RE
LEAS
E
KEYP
AD / C
ARD
GND
(-)(+)
GND
GND
MAX
OPEN
FIRE
DEP
T
RADI
O GN
DRA
DIO
SIGNA
L
STRI
KE
CLOS
ECO
M
COM
STOP
OPEN
CLS ONLY 10KOPEN/CLS 10K
12VDC OUT
NOCOM
NC
ID PLUGERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP PWROFF
PRIMARY
LEFT
ON/OFFBATTERY
RIGHT
SECONDARY
ON
QUICKCLOSE
OPENLEFT
OPEN RIGHT
GATEOFF
123456789
10
123456
MIN MIN
MAX MAX
ON
OFF 2.5 sec1.5 sec
FAULTSOPERATOR
MATRIX III
OFF
OFF
3
1
1416
MIN16
MIN12
9
73
1
14 12
9
7
UL S
ENSO
R N.
C.UL
SEN
SOR
10K
POWER
MODE
AMO
DE B
EXIT LOOP
LOOP
LOOP
CENTER
SAFETY
GATE OPENCOM
GATE CLOSED
MIN
MATRIX IIISWING / SLIDE
www.max.us.com
EMX WEL-200 Wiring GuideFOR MAX PRO SERIES
WIRE WEL-200R OPEN & CLOSE RELAYSTO MATRIX III10K SENSOR INPUTS
WIRE TO ‘NO’ OF RELAY OPEN
WIRE TO ‘NO’ OF RELAY CLOSE
1INSERT BOTH JUMPERSIN 10K POSITION
2
Polarity does
NOT matterfor power
Connecting is a two step process. First, on the receiver, press and hold the channel assignment switch until the green status LED begins rapidly flashing, then release; this will clear any existing assignment for that particular channel. Hold down the connection switch on the transmitter. If it is not currently connected to a receiver, it will begin flashing rapidly until successfully connecting. Detailed instructions are given below.
If there are no existing connections, the receiver’s status LED will blink rapidlywhile it is finding a clean operating frequency (this can last a few seconds) After initialization, the system status LED will flash on/off once every 2 seconds
Set channel to the desired OPEN/CLOSE direction function using the MODE dip switch
Install 2 AA Lithium batteries in the WEL-200T (transmitter)
The green LED on the transmitter will quickly flash 2x every two seconds
Install a properly terminated edge to the transmitter (8.2k or 10k termination)
On the receiver, hold down the desired channel assignment switch until all four channel LED’s activate and the system status LED begins flashing rapidly, then release the switch.
On the transmitter, hold down the connection switch (next to the terminal block) The LED on the transmitter will begin flashing rapidly after ~4 seconds
Upon successful connection, the LED will flash once every two seconds If the transmitter fails to connect, it will return to its initial state, with the LED flashing twice every two seconds. If this occurs, repeat step