Top Banner
Emittance measurements for low charge operation with short-pulse injector laser at FLASH M. Rehders 25.03.2014 - FLASH Seminar
27

Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

Sep 09, 2018

Download

Documents

danglien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

Emittance measurements for low charge operation with short-pulse

injector laser at FLASH

M. Rehders

25.03.2014 - FLASH Seminar

Page 2: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

Motivation

Time resolved experiments: time resolution is limited by the pulse length of the radiation pulse Pulse can be used as a pump and/or probe pulse Shorter pulses shorter time scales can be studied Imaging experiments: short pulses prevent structural damage while the image is taken

2 (Neutze, R., Wouts, R., van der Spoel, D., Weckert, E. Hajdu, J. (2000) Nature 406, 752-757)

Coulomb Explosion of Lysozyme

(50 fs) LCLS

Radiation damage interferes with atomic positions and the

atomic scattering factors

Page 3: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

outline

• Generation of extremely short SASE pulses at FLASH – Why do we need a short pulse injector laser (Laser3)?

• Influence of the injector laser pulse durations on electron bunch parameters for low charges – Simulation results

• Emittance measurements for low charges at FLASH – Laser2

– Laser3 • solenoid scan

• Challenges for low charges

– Comparison for identical machine settings

3

Page 4: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

4

Generation of femtosecond scale radiation pulses at FLASH

Typical FLASH parameters

Single spike operation at FLASH

Injector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps

Bunch charge 0.08 – 1 nC 20 pC

Compression factor 200 – 50 1600 350 – 700

FEL pulse duration (FWHM) 30 – 200 fs ~ 3 fs

Photon

Diagnostics

315 m

Bunch

Compressors

Soft X-ray

Undulators sFLASH

3rd

harmonics

5 MeV 150 MeV 450 MeV 1250 MeV

Accelerating Structures Diagnostics

FEL

Experiments

RF stations

LOLA

Page 5: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

single spike limit

5

determined by slippage of photon pulse w.r.t. particles during 1 FEL gain length σz,ph. min ≈ 1μm (at FLASH)

Longitudinal SASE profile

Genesis 1.3 simulations

Longitudinal SASE profile

30 fs 3 fs

Page 6: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

6

Generation of femtosecond scale radiation pulses at FLASH

Typical FLASH parameters

Very short pulses at FLASH

Injector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps

Bunch charge 0.08 – 1 nC 20 pC

Compression factor 200 – 50 1600 350 – 700

FEL pulse duration (FWHM) 30 – 200 fs ~ 3 fs

A large compression factor requires large RF stability which is technically very challenging

Requires further reduction of bunch lengths already at the injector

Photon

Diagnostics

315 m

Bunch

Compressors

Soft X-ray

Undulators sFLASH

3rd

harmonics

5 MeV 150 MeV 450 MeV 1250 MeV

Accelerating Structures Diagnostics

FEL

Experiments

RF stations

LOLA

Page 7: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

7

Generation of femtosecond scale radiation pulses at FLASH

Typical FLASH parameters

Very short pulses at FLASH

Injector laser pulse duration (FWHM) 15 ps 15 ps 1.7-3.7 ps

Bunch charge 0.08 – 1 nC 20 pC

Compression factor 200 – 50 1600 350 – 700

FEL pulse duration (FWHM) 30 – 200 fs ~ 3 fs

New short pulse injector laser has been installed

Photon

Diagnostics

315 m

Bunch

Compressors

Soft X-ray

Undulators sFLASH

3rd

harmonics

5 MeV 150 MeV 450 MeV 1250 MeV

Accelerating Structures Diagnostics

FEL

Experiments

RF stations

LOLA

Page 8: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

SASE simulation from start-to-end simulation for FLASH

8

Longitudinal SASE distribution SASE spectrum

for four different statistical seeds

2-3 fs FWHM

• Resulting from start-to-end simulation for FLASH

• Settings very close to real machine settings (optics) (not optimized)

• Longitudinal space charge forces and wakefields in the undulator are not included in the Genesis simulation

Page 9: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

outline

• Generation of extremely short SASE pulses at FLASH – Why do we need a short pulse injector laser (Laser3)?

• Influence of the injector laser pulse durations on electron bunch parameters for low charges – Simulation results

• Emittance measurements for low charges at FLASH – Laser2

– Laser3 • solenoid scan

• Challenges for low charges

– Comparison for identical machine settings

9

Page 10: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

10

ASTRA simulations for 20pC From simulation: Reduction of bunch length by factor 3-5 doesn‘t increase the transverse emittance

If this is the case, short pulse laser is well suited for low charge, short bunch operation

Has to be verified by measurements!

influence of injector laser pulse duration at 20pC

0,0

0,2

0,4

0,6

0,8

1,0

1,2

1,4

1,6

1,8

0 1 2 3 4 5 6 7

rms

bu

nch

len

gth

(m

m)

rms laser pulse duration (ps)

BSA 0.4 mm

BSA 0.8 mm

BSA 1.2 mm

standard laser short pulse laser

0,00

0,05

0,10

0,15

0,20

0,25

0,30

0,35

0,40

0,45

0,50

0 1 2 3 4 5 6 7

min

imu

m e

mit

tan

ce (

π m

m m

rad

)

rms laser pulse duration (ps)

iris 0.4 mm

iris 0.8 mm

iris 1.2 mm

standard laser (15ps FWHM)

short pulse laser (1.7-3.7ps FWHM)

BSA 0.4 mm

BSA 0.8 mm

BSA 1.2 mm

Page 11: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

11

Longitudinal Phase Space Distribution after the Gun

Charge: 20pC solenoid field: 192mT BSA: 0.6 mm gun phase: maximum energy gain (5MeV) 2 different laser pulse durations

head tail

1.5 A

Laser2 (15ps FWHM)

Page 12: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

12

Longitudinal Phase Space Distribution after the Gun

Charge: 20pC solenoid field: 192mT BSA: 0.6 mm gun phase: maximum energy gain (5MeV) 2 different laser pulse durations

head tail

1.5 A 5 A

Laser2 (15ps FWHM) Laser3, 2.4ps FWHM

Page 13: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

simulation of solenoid scan

13

10 ps (FWHM) 2.4 ps (FWHM)

ASTRA simulations for 20pC

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,170 0,175 0,180 0,185 0,190 0,195 0,200

x e

mit

tan

ce (

pi m

m m

rad

) solenoid field (T)

1.0 ps,0.1 mm

1.0 ps,0.2 mm

1.0 ps,0.3 mm

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,170 0,175 0,180 0,185 0,190 0,195 0,200

x e

mit

tan

ce (

pi m

m m

rad

)

solenoid field (T)

6.5 ps,0.1 mm

6.5 ps,0.2 mm

6.5 ps,0.3 mm

Page 14: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

outline

• Generation of extremely short SASE pulses at FLASH – Why do we need a short pulse injector laser (Laser3)?

• Influence of the injector laser pulse durations on electron bunch parameters for low charges – Simulation results

• Emittance measurements for low charges at FLASH – Laser2

– Laser3 • solenoid scan

• Challenges for low charges

– Comparison for identical machine settings

14

Page 15: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

Emittance measurement laser2

15

Measurement 2012/11/14

LASER-2, BSA=0.5mm, 20pC, Isol=-317.0A

12 bunches

Expected from simulation: 0.20 mm mrad

Measurements with 20pC: No signal at BPMs very time consuming more recent measurements have been performed with higher charge

Emittance alpha beta BMAG

horizontal 0.20 +0.13−0.07

-1.41 2.10 1.59

vertical 0.43 +0.14−0.08

1.63 3.42 1.34

Page 16: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

outline

• Generation of extremely short SASE pulses at FLASH – Why do we need a short pulse injector laser (Laser3)?

• Influence of the injector laser pulse durations on electron bunch parameters for low charges – Simulation results

• Emittance measurements for low charges at FLASH – Laser2

– Laser3 • solenoid scan

• Challenges for low charges

– Comparison for identical machine settings

16

Page 17: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

Matching

0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0,9

0 1 2 3 4 5

emit

tan

ce

matching iteration

x, EmitTool

y, EmitTool

x, OpticsTool

y, OpticsTool

0

1

2

3

4

5

6

0 1 2 3 4 5

BM

AG

matching iteration

x, EmitTool

y, EmitTool

x, OpticsTool

y, OpticsTool

Matching works only in a narrow window between 310 -315 A It was not possible to perform the planned solenoid scan to the expected

minimum

Still, very small emittance values have been measured

Matching with Optics Tool by W. Decking

17

Measurement 2013/12/22

Page 18: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

Solenoid scan

0

0,5

1

1,5

2

2,5

310 312 314 316

BM

AG

solenoid current (A)

x, EmitTool

y, EmitTool

x, OpticsTool

y, OpticsTool

LASER-3: 2ps (FWHM) Bunch charge: 30pC BSA: 0.4mm Expected emittance from the simulation: Approx. 0.36 mm mrad for 30 pC

18

Measurement 2013/12/22

0

0,2

0,4

0,6

0,8

1

310 311 312 313 314 315 316

emit

tan

ce (

pi m

m m

rad

)

solenoid current (A)

x, EmitTooly, EmitToolx, OpticsTooly, OpticsToolsimulation

Page 19: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

Tiny spot sizes

Camera resolution is 11μm (rms, Gaussian) we‘re getting close to the limit!

19

Measurement 2013/12/22

Page 20: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

LASER-3, 2ps FWHM, BSA=0.4, 30pC, Isol=312.5A

10 bunches

Expected from simulation: 0.37 mm mrad

emittance alpha beta BMAG

horizontal 0.46 +0.06−0.05

-1.32 2.41 1.28

vertical 0.62 +0.09−0.08

1.14 2.76 1.15

Influence of the number of bunches used for the measurement

Measurement 2013/12/22

Page 21: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

LASER-3, 2ps FWHM, BSA=0.4, 30pC, Isol=312.5A

10 bunches

Expected from simulation: 0.37 mm mrad

LASER-3, 2ps FWHM, BSA=0.4, 30pC, Isol=312.5A

1-2 bunches

Expected from simulation: 0.37 mm mrad

emittance alpha beta BMAG

horizontal 0.46 +0.06−0.05

-1.32 2.41 1.28

vertical 0.62 +0.09−0.08

1.14 2.76 1.15

emittance alpha beta BMAG

horizontal 0.34 +0.06−0.05

-1.15 2.19 1.24

vertical 0.43 +0.09−0.08

1.02 2.83 1.32

Influence of the number of bunches used for the measurement

Measurement 2013/12/22

Page 22: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

LASER-3, 2ps FWHM, BSA=0.4, 30pC, Isol=312.5A

10 bunches

Expected from simulation: 0.37 mm mrad

LASER-3, 2ps FWHM, BSA=0.4, 30pC, Isol=312.5A

1-2 bunches

Expected from simulation: 0.37 mm mrad

emittance alpha beta BMAG

horizontal 0.46 +0.06−0.05

-1.32 2.41 1.28

vertical 0.62 +0.09−0.08

1.14 2.76 1.15

emittance alpha beta BMAG

horizontal 0.34 +0.06−0.05

-1.15 2.19 1.24

vertical 0.43 +0.09−0.08

1.02 2.83 1.32

Influence of the number of bunches used for the measurement

For many bunches, the emittance can be about 40% larger!

Measurement 2013/12/22

Page 23: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

emittance alpha beta BMAG

horizontal 0.15 +0.18−0.10

-2.13 2.87 2.19

vertical 0.26 +0.31−0.16

2.02 4.05 1.62

LASER-2: 15ps FWHM

BSA=0.4mm, 30pC, Isol=310.4A, 1-2 bunches

Expected from simulation: 0.25 mm mrad

Comparison of Laser2 and Laser3 at identical machine settings

Measurement 2013/12/22

Page 24: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

emittance alpha beta BMAG

horizontal 0.15 +0.18−0.10

-2.13 2.87 2.19

vertical 0.26 +0.31−0.16

2.02 4.05 1.62

LASER-2: 15ps FWHM

BSA=0.4mm, 30pC, Isol=310.4A, 1-2 bunches

Expected from simulation: 0.25 mm mrad

LASER-3: 2ps FWHM

BSA=0.4mm, 30pC, Isol=310.4A, 1-2 bunches

Expected from simulation: 0.37 mm mrad

Comparison of Laser2 and Laser3 at identical machine settings

emittance alpha beta BMAG

horizontal 0.15 +0.19−0.10

-2.29 3.11 2.26

vertical 0.25 +0.33−0.16

1.83 5.06 2.14

Measurement 2013/12/22

Page 25: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

conclusion

• Single spike SASE radiation at FLASH requires

– low charges

– short laser pulse duration at injector

• Very small emittance has been demonstrated for low charge

– Comparable for long and short laser pulses (30pC)

supports simulation results

Error bars still large due to matching + sensitivity of screens

• Emittance measurement for low charges with screen method

requires a more sensitive screen/camera

25

Page 26: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

outlook

Systematic study of influence of number of bunches on emittance measurements

Confirm the comparison between lasers 2 & 3 by more measurements (better BMAG, statistics)

bunch length measurements in BC2

26

Page 27: Emittance measurements for low charges at FLASH fileInjector laser pulse duration (FWHM) 15 ps 15 ps 1-3 ps Bunch charge 0.08 – 1 nC 20 pC Compression factor 200 – 50 1600 350

Thank you for your attention!

27