For links to all Isilon customer troubleshooting guides, visit the Customer Troubleshooting - Isilon Info Hub. We appreciate your help in improving this document. Submit your feedback at http://bit.ly/isilon-docfeedback. ___________________________ 1 - EMC Isilon Customer Troubleshooting Guide: Troubleshoot Issues with SNMP on Your Isilon Cluster ___________________ Abstract This guide helps you troubleshoot issues with SNMP on your Isilon cluster. April 29, 2019 EMC ISILON CUSTOMER TROUBLESHOOTING GUIDE TROUBLESHOOT ISSUES WITH SNMP ON YOUR ISILON CLUSTER OneFS 7.2 - 8.x
20
Embed
EMC Isilon Customer Troubleshooting Guide: Troubleshoot ......1 - EMC Isilon Customer Troubleshooting Guide: Troubleshoot Issues with SNMP on Your Isilon Cluster _____ Abstract This
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
For links to all Isilon customer troubleshooting guides, visit the Customer Troubleshooting - Isilon Info Hub.
We appreciate your help in improving this document. Submit your feedback at http://bit.ly/isilon-docfeedback.
___________________________
1 - EMC Isilon Customer Troubleshooting Guide: Troubleshoot Issues with SNMP on Your Isilon Cluster
___________________
Abstract This guide helps you troubleshoot issues with SNMP on your Isilon cluster.
April 29, 2019
EMC ISILON CUSTOMER TROUBLESHOOTING GUIDE
TROUBLESHOOT ISSUES WITH SNMP ON YOUR ISILON CLUSTER
For links to all Isilon customer troubleshooting guides, visit the Customer Troubleshooting - Isilon Info Hub.
We appreciate your help in improving this document. Submit your feedback at http://bit.ly/isilon-docfeedback.
___________________________
3 - EMC Isilon Customer Troubleshooting Guide: Troubleshoot Issues with SNMP on Your Isilon Cluster
___________________
Before you begin
CAUTION!If the node, subnet, or pool that you are working on goes down during the course of troubleshooting and you do not have any other way to connect to the cluster, you could experience data unavailability.
Therefore, make sure that you have more than one way to connect to the cluster before you start this troubleshooting process. The best method is to have a serial console connection available. This way, if you are unable to connect through the network, you will still be able to connect to the cluster physically.
For specific requirements and instructions for making a physical connection to the cluster, see article 304071 on the EMC Online Support site.
Before you begin troubleshooting, confirm that you can connect through either another subnet or pool, or that you have physical access to the cluster.
Configure screen logging through SSHWe recommend that you configure screen logging to log all session input and output during your troubleshooting session. This log file can be shared with Isilon Technical Support, if you require assistance at any point during troubleshooting.
1. Open an SSH connection to the cluster and log in by using the root account.
Note: If the cluster is in compliance mode, use the compadmin account to log in. All compadmin commands must be preceded by the sudo prefix.
2. Change the directory to / i f s/ dat a/ I si l on_Suppor t by running the following command:
cd / i f s/ dat a/ I si l on_Suppor t
3. Run the following command to capture all input and output from the session:
scr een - L
This will create a file named scr eenl og. 0 that will be appended to during your session.
For links to all Isilon customer troubleshooting guides, visit the Customer Troubleshooting - Isilon Info Hub.
We appreciate your help in improving this document. Submit your feedback at http://bit.ly/isilon-docfeedback.
___________________________
6 - EMC Isilon Customer Troubleshooting Guide: Troubleshoot Issues with SNMP on Your Isilon Cluster
___________________
Unable to view SNMP data (2)
Verify that the SNMP services is running on all nodes by running the following command for your version of OneFS,
Note: "- l " is a dash and lower case "L".
OneFS 8.xi si _f or _ar r ay - sX ' pgr ep snmp | wc - l '
OneFS 7.2i si _f or _ar r ay - sX ' pgr ep snmpd | wc - l '
If the SNMP service is running on every node, the output will look similar to this example:
cl ust er - 2# i si _f or _ar r ay - sX ' pgr ep snmp| wc - l 'cl ust er - 1: 1cl ust er - 2: 1cl ust er - 3: 1
Page 6
You could have arrived here from:
- Page 5 - Unable to view SNMP data
Is the service running
on all nodes?
Refer toFor clusters running OneFS 8.x, see the "Configure the cluster for SNMP monitoring" section of the OneFS 8.0.0 CLI Administration Guide to verify the SNMP-specific security level.
For links to all Isilon customer troubleshooting guides, visit the Customer Troubleshooting - Isilon Info Hub.
We appreciate your help in improving this document. Submit your feedback at http://bit.ly/isilon-docfeedback.
___________________________
10 - EMC Isilon Customer Troubleshooting Guide: Troubleshoot Issues with SNMP on Your Isilon Cluster
___________________
Unable to view SNMP data (6)
Page 10
You could have arrived here from:
- Page 6 - Unable to view SNMP data (2)- Page 8 - Unable to view SNMP data (4)
Determine if SNMP is using a custom port by running the following command for your version of OneFS:
OneFS 8.xcat / et c/ snmpd. conf i g | gr ep SnmpdPor t
Example output, the port is indicated by the bold text:begemot SnmpdPor t St at us. 0. 0. 0. 0. 161 = 1begemot SnmpdPor t v6St at us. 0: 0: 0: 0: 0: 0: 0: 0. 161 = 1
OneFS 7.2gr ep - i " agent addr ess" / et c/ mcp/ t empl at es/ snmp_snmpd. conf
If SNMP is using the default port 161, there will be no output from this command.
If the output looks similar to the following, SNMP is using the custom port specified in the output. In this example, the custom port is 171:
agent Addr ess udp: 171
To verify that the SNMP service is listening on all nodes, run the following command where <por t > is the SNMP port number that you
identified in the previous step.
Note: The default is 161 unless you have configured a custom port.
i si _f or _ar r ay - sX ' net st at - al n | gr ep " * . <por t >" '
For example: i si _f or _ar r ay - sX ' net st at - al n | gr ep " * . 161" '
See Appendix C for example output.
Is the SNMP service listening
on all nodes?
Note the page number that you are currently on.
Upload log files and contact Isilon Technical Support, as instructed in Appendix A.
For links to all Isilon customer troubleshooting guides, visit the Customer Troubleshooting - Isilon Info Hub.
We appreciate your help in improving this document. Submit your feedback at http://bit.ly/isilon-docfeedback.
___________________________
11 - EMC Isilon Customer Troubleshooting Guide: Troubleshoot Issues with SNMP on Your Isilon Cluster
___________________
Unable to view SNMP data (7)
Page 11
You could have arrived here from:
- Page 10 - Unable to view SNMP data (6)
From the SNMP host, try to ping the IP address of the node that you
are attempting to connect to:
pi ng <I Paddr ess>
Is the SNMP host able to ping the
node IP address?No
Note the page number that you are currently on.
Upload log files and contact Isilon Technical Support, as instructed in
Appendix A.
Yes
From the SNMP host, verify that you can connect to the SNMP port. Run the following command, where <I P> is the IP address of the node, and <por t > is the SNMP port number that you identified on page 10:
For Linux/BSD SNMP hostsnc - u - z <I P> <por t >
For example:nc - u - z 10. 1. 1. 11 161
For Windows hostsThere is no native tool on Windows to test this. Optionally, you may
install the Microsoft® PortQry Command Line Port Scanner (see Appendix D for instructions on downloading and using the tool). If you
are unable to use the Microsoft® tool, you will need to use a Linux machine. If you do not have access to a Linux machine, have your Networking team verify whether the SNMP port can be reached.
For links to all Isilon customer troubleshooting guides, visit the Customer Troubleshooting - Isilon Info Hub.
We appreciate your help in improving this document. Submit your feedback at http://bit.ly/isilon-docfeedback.
___________________________
15 - EMC Isilon Customer Troubleshooting Guide: Troubleshoot Issues with SNMP on Your Isilon Cluster
___________________
Incorrect SNMP data (2)
Page 15
You could have arrived here from:
- Page 14 - Incorrect SNMP data
Perform a full snmpwalk and save it. Depending on which SNMP version you are using, run the following two commands, where <commname> is the
community name.
Note: for each version of SNMP, there are two full commands. Copy and paste the commands into the cluster CLI and remove any hard line breaks. Press Enter to execute the command.
SNMP v2snmpwal k - v2c - c <commname> - m / usr / l ocal / shar e/ snmp/ mi bs/ I SI LON- MI B. t xt l ocal host >
/ var / cr ash/ snmpwal k. out
snmpwal k - v2c - c <commname> - m / usr / l ocal / shar e/ snmp/ mi bs/ I SI LON- MI B. t xt l ocal host I si l on >> / var / cr ash/ snmpwal k. out
SNMP v3snmpwal k ?v3 ?e <engi ne I D> - l noaut hnopr i v ?u <user name> - mALL l ocal host > / var / cr ash/ snmpv3wal k. out
snmpwal k ?v3 ?e <engi ne I D> - l noaut hnopr i v ?u <user name> - mALL l ocal host I si l on >> / var / cr ash/ snmpv3wal k. out
Gather a full log set that includes the snmpwalk
i si _gat her _i nf o - f / var / cr ash/ snmpwal k. out
Gather the following information:
- An example of the inaccurate reporting you are experiencing.- What you expect the report to show.- Your SNMP host configuration.
Note the page number that you are currently on.
Upload log files and contact Isilon Technical Support, as instructed in
For links to all Isilon customer troubleshooting guides, visit the Customer Troubleshooting - Isilon Info Hub.
We appreciate your help in improving this document. Submit your feedback at http://bit.ly/isilon-docfeedback.
___________________________
16 - EMC Isilon Customer Troubleshooting Guide: Troubleshoot Issues with SNMP on Your Isilon Cluster
___________________
Appendix A: If you need further assistance
___________
Contact Isilon Technical SupportIf you need to contact Isilon Technical Support during troubleshooting, reference the page or step that you need help with. This information and the log file will help Isilon Technical Support staff resolve your case more quickly.
Upload node log files and the screen log file to Isilon Technical Support1. When troubleshooting is complete, in the command-line interface, type exi t to end your screen session.2. Gather and upload the node log set and include the SSH screen log file by using the command appropriate for
your method of uploading files. If you are not sure which method to use, use FTP.
ESRS:
i si _gat her _i nf o - - esr s - - l ocal - onl y - f / i f s/ dat a/ I si l on_Suppor t / scr eenl og. 0
FTP:
i si _gat her _i nf o - - f t p - - l ocal - onl y - f / i f s/ dat a/ I si l on_Suppor t / scr eenl og. 0
HTTP:
i si _gat her _i nf o - - ht t p - - l ocal - onl y - f / i f s/ dat a/ I si l on_Suppor t / scr eenl og. 0
SMTP:
i si _gat her _i nf o - - emai l - - l ocal - onl y - f / i f s/ dat a/ I si l on_Suppor t / scr eenl og. 0
SupportIQ:Copy and past the following command.Note: When you copy and paste the command into the command-line interface, it will appear on multiple lines (exactly as it appears on the page), but when you press Enter, the command will run as it should.
i si _gat her _i nf o - - l ocal - onl y - f / i f s/ dat a/ I si l on_Suppor t / scr eenl og. 0 - - noupl oad \ - - syml i nk / var / cr ash/ Suppor t I Q/ upl oad/ f t p
3. If you receive a message that the upload was unsuccessful, refer to article 304567 on the Dell EMC Online Support site for directions on how to upload files over FTP.
For links to all Isilon customer troubleshooting guides, visit the Customer Troubleshooting - Isilon Info Hub.
We appreciate your help in improving this document. Submit your feedback at http://bit.ly/isilon-docfeedback.
___________________________
17 - EMC Isilon Customer Troubleshooting Guide: Troubleshoot Issues with SNMP on Your Isilon Cluster
___________________
Decision diamondYes No
Process stepProcess step with command:
command xyz
Go to Page #
Page # Note
Provides context and additional information. Sometimes a note is linked to a process step with a colored dot.
CAUTION!Caution boxes warn that a particular step needs to be performed with great care, to prevent serious consequences.
End pointDocument ShapeCalls out supporting documentation for a process step. When possible, these shapes contain links to the reference document.Sometimes linked to a process step with a colored dot.
Optional process step
IntroductionDescribes what the section helps you to accomplish.
For links to all Isilon customer troubleshooting guides, visit the Customer Troubleshooting - Isilon Info Hub.
We appreciate your help in improving this document. Submit your feedback at http://bit.ly/isilon-docfeedback.
___________________________
19 - EMC Isilon Customer Troubleshooting Guide: Troubleshoot Issues with SNMP on Your Isilon Cluster
___________________
Appendix D: Instructions for downloading and using PortQry
You could have arrived here from:
- Page 11 - Unable to view SNMP data (7)
Using the Microsoft PortQry Command Line Port Scanner
Download the tool here:http://www.microsoft.com/en-us/download/details.aspx?id=17148
The command syntax for the tool is:por t qr y - n <I P> - p udp - e <por t > - nr | f i ndst r / B " UDP"
If the port is reachable, the response is similar to one of the following:UDP por t 161 ( snmp ser vi ce) : LI STENI NGUDP por t 161 ( snmp ser vi ce) : FI LTERED
If the port is not reachable, the response is similar to the following:UDP por t 161 ( snmp ser vi ce) : NOT LI STENI NG
Dell believes the information in this publication is accurate as of its publication date. The information is subject to change without notice.
THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS-IS." DELL MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. USE, COPYING, AND DISTRIBUTION OF ANY DELL SOFTWARE DESCRIBED IN THIS PUBLICATION REQUIRES AN APPLICABLE SOFTWARE LICENSE.
Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the property of their respective owners.
EMC CorporationHopkinton, Massachusetts 01748-91031-508-435-1000 in North America 1-866-464-7381www.EMC.com