Embedded 1-Single Door Controller Features Simple to use, Self-Contained, Scalable Access Control Solution Each controller functions as a Server, expansion panel or elevator module Ready out of the box, browser-managed Embedded Linux Operating System 2 Readers (In / Out) – 1 Door Only 2 Form C Relays (Lock and Auxiliary) Global 3 Inputs (Request to Exit, Door Position Switch, Auxiliary) Global ETL – UL294 1 Gigabit Auto Sensing Ethernet Port Includes Mounting Bracket 5-Year Hardware Warranty CAE-1DC 1-Door Controller, with Mobile App Expandable up to 64 controllers/128 doors Requires 12 DC power CONTINENTAL, A DIVISION OF NAPCO SECURITY TECHNOLOGIES, INC. 355 BAYVIEW AVE., | AMITYVILLE, NY 11701 | 1.800.645.9445 | 631.842.9400 | FAX 631.842.9135 | WWW.CICACCESS.COM E-ACCESS IS A TRADEMARK OF CONTINENTAL DIVISION OF NAPCO. OTHER TRADEMARKS INDICATED ARE PROPERTY OF THEIR RESPECTIVE COS. PDS, SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE (C) 10.2020 A787 Model CAE-1DC Processor Quad Core Cortex, 1.5 GHz Memory 1 GB DDR3 & 8 GB eMMc Operating System Embedded Linux Transactions > 45 per second System Power Requirements Regulated 12VDC @ 2A, Class 2 (not supplied) Operating Temperature 50°F to 95°F (10°C to 35°C) Enclosure Size (W x H x D) 3.2 x 3.0 x 1.3in (81 x 78 x 32mm) Standby Power Requirement 350mA @ 12V Number of Doors 2 Total, One In & One Reader Readers (Wiegand) 2 Total, One In & One Out Reader for Each Door Reader Power 300mA @ 12V Max per Reader 600mA @ 12V Max per System Request to Exit (REX) Inputs 1 Total, One for Each Door Door Position (status) Inputs 1 Total, One for Each Door Auxiliary Input 1 Total, General Purpose Tamper Digital Input N/A Power Fault Digital Input N/A Door Lock Outputs 1 Form C Relay, 24V @ 1.0A Auxiliary Outputs 1 Form C Relay, 24V @ 1.0A Optional Accessary POE-1DC– 12VDC 2A POE Power Supply
1

Embedded 1-Single Door Controller

Jan 26, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Embedded 1-Single Door Controller

Embedded 1-Single Door Controller

Features• Simple to use, Self-Contained,

Scalable Access Control Solution

• Each controller functions as a Server, expansion panel or elevator module

• Ready out of the box, browser-managed

• Embedded Linux Operating System

• 2 Readers (In / Out) – 1 Door Only

• 2 Form C Relays (Lock and Auxiliary) Global

• 3 Inputs (Request to Exit, Door Position Switch, Auxiliary) Global

• ETL – UL294

• 1 Gigabit Auto Sensing Ethernet Port

• Includes Mounting Bracket

• 5-Year Hardware Warranty

CAE-1DC 1-Door Controller, with Mobile App Expandable up to 64 controllers/128 doors Requires 12 DC power

CONTINENTAL, A DIVISION OF NAPCO SECURITY TECHNOLOGIES, INC. 355 BAYVIEW AVE., | AMITYVILLE, NY 11701 | 1.800.645.9445 | 631.842.9400 | FAX 631.842.9135 | WWW.CICACCESS.COM

E - A CC E S S I S A T R A D E M A R K O F CO N T I N E N TA L D I V I S I O N O F N A P CO. OT H E R T R A D E M A R K S I N D I CAT E D A R E P R O P E R T Y O F T H E I R R E S P E C T I V E CO S . P D S , S P E C I F I CAT I O N S S U B J E C T TO C H A N G E W I T H O U T P R I O R N OT I C E ( C ) 1 0 . 2 0 2 0 A 7 8 7

Model CAE-1DCProcessor Quad Core Cortex, 1.5 GHz

Memory 1 GB DDR3 & 8 GB eMMc

Operating System Embedded Linux

Transactions > 45 per second

System Power Requirements

Regulated 12VDC @ 2A, Class 2 (not supplied)

Operating Temperature 50°F to 95°F (10°C to 35°C)

Enclosure Size (W x H x D) 3.2 x 3.0 x 1.3in (81 x 78 x 32mm)

Standby Power Requirement

350mA @ 12V

Number of Doors 2 Total, One In & One Reader

Readers (Wiegand) 2 Total, One In & One Out Reader for Each Door

Reader Power 300mA @ 12V Max per Reader 600mA @ 12V Max per System

Request to Exit (REX) Inputs

1 Total, One for Each Door

Door Position (status) Inputs

1 Total, One for Each Door

Auxiliary Input 1 Total, General Purpose

Tamper Digital Input N/A

Power Fault Digital Input N/A

Door Lock Outputs 1 Form C Relay, 24V @ 1.0A

Auxiliary Outputs 1 Form C Relay, 24V @ 1.0A

Optional Accessary• POE-1DC–