GND +VIN GND Door Strike Input Input Ground Ground Normally Closed Contact Common Contact Door Status Normally Open Contact Common Contact REX Door Strike P/S (+) (+) (-) (-) Transorb (Voltage Supression), Siemens S10K30 or equiv. Maglock (Battery backed) Strike P/S (Battery backed) Door A Door B CABLING INFORMATION Ref. Connection Conductors A.W.G Gauge Max ft. A RS-485 Communications Cable 4* #24 4000** (1220 m) B Proximity Reader to EMC 6 #22 500 (152 m) C Door Strike to EMC 2 #18 500 (152 m) D REX to EMC 2 #22 1000 (305 m) E Door Status Contact 2 #22 500 (152 m) -All cabling must be stranded with overall shielding. -Ground all (except RS-485) cable shield/drain wires to ground screw in cabinet. Follow open-ended grounding method (i.e., tape back shield/drain wire at other end). *One conductor not used from one of RS-485 twisted pairs. **End to end. (or) (Back of Board) C C D E Reader A Reader B COM IN COM OUT +LOC ALM -LOC ALM COM NORM OPEN NORM CLOSED REX REX DOOR STAT DOOR STAT +LOC ALM -LOC ALM COM NORM OPEN NORM CLOSED REX REX DOOR STAT DOOR STAT +LOC ALM -LOC ALM COM NORM OPEN NORM CLOSED REX REX DOOR STAT DOOR STAT +LOC ALM -LOC ALM COM NORM OPEN NORM CLOSED REX REX DOOR STAT DOOR STAT +5 W1 +12 (see detail) L1 RD 0 RD 1 P O W E R Door Strike or Maglock (Reader voltage jumper selected at factory) NOTE: See Reader Manufacturer's wiring specifications for LED Control Info. Proximity Reader B Diode (1N4004 or equiv.) for Counter EMF protection W3 Jumper (Factory-set as shown) (Do not Change) Transorb (Voltage Supression), Siemens S10K30 or equiv. Diode (1N4004 or equiv.) for Counter EMF protection For a Stand-Alone System: Keep W2 jumper in TIN position. For a Multi-EMC System: refer to other side of sheet. Door Sense A L7 Activity Light L5 Tamper Switch L6 N/A L4 REX B L2 REX A L3 Door Sense B EMC Address Dipswitching (EMCs must be sequentially addressed starting with Address 1) (Top part of Front of Board) RX TX TP3 +12V TP4 +5V W2 Jumper TOUT TIN EM3000 Page 1 For multi-EMC config. instructions, refer to to the other side. (Bottom part of Front of Board) 1540F1 Doc 6001540, Rev D RS232-485 CONVERTER A Red w/white stripe Black BATTERY Backed/Regulated 1.0 Amp @ 12 VDC Power Supply Board Ground Neutral Hot GRN WHT BLK To 110 VAC at Junction Box or Breaker Panel TB1 TB2 + IN - + OUT - Output + - C Red Black Low Voltage Disconnect Module + -
2

EM3000 QUICK INSTALLATION GUIDE - LiftMaster · (see detail) L1 RD 0 RD 1 P O W E R Door Strike ... RTN To PC Case Screw One Conductor ... the EMC boards must be addressed in order,

Apr 08, 2018

Download

Documents

phamquynh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: EM3000 QUICK INSTALLATION GUIDE - LiftMaster · (see detail) L1 RD 0 RD 1 P O W E R Door Strike ... RTN To PC Case Screw One Conductor ... the EMC boards must be addressed in order,

DATA

1

GN

D+V

ING

ND

Door Strike

Input

Input

Ground

Ground

NormallyClosed Contact

CommonContact

DoorStatus

NormallyOpen Contact

CommonContact

REX

DoorStrikeP/S (+)

(+)

(-)

(-)

Transorb (Voltage Supression),Siemens S10K30 or equiv.

Maglock

(Batterybacked)

StrikeP/S

(Batterybacked)

Door A

Door B

CABLING INFORMATION

Ref. Connection Conductors A.W.G Gauge Max ft.

A RS-485 Communications Cable 4* #24 4000** (1220 m)

B Proximity Reader to EMC 6 #22 500 (152 m)

C Door Strike to EMC 2 #18 500 (152 m)

D REX to EMC 2 #22 1000 (305 m)

E Door Status Contact 2 #22 500 (152 m)

-All cabling must be stranded with overall shielding.-Ground all (except RS-485) cable shield/drain wires to ground screw in cabinet. Follow open-ended grounding method (i.e., tape back shield/drain wire at other end).*One conductor not used from one of RS-485 twisted pairs.**End to end.

(or)(Back of Board)

Quick Installation Guide

C

C

D E

Reader A

Reader B

COM IN

COM OUT

+LOCALM

-LOCALMCOMNORMOPENNORMCLOSEDREX

REX

DOOR STAT

DOOR STAT

+LOCALM

-LOCALMCOMNORMOPENNORMCLOSEDREX

REX

DOOR STAT

DOOR STAT

+LOCALM

-LOCALMCOMNORMOPENNORMCLOSEDREX

REX

DOOR STAT

DOOR STAT

+LOCALM

-LOCALMCOMNORMOPENNORMCLOSEDREX

REX

DOOR STAT

DOOR STAT

+5W1+12

(see detail)

L1 RD0

RD1

POWER

Door Strike or Maglock

(Reader voltage jumper selected at factory)

NOTE: See Reader Manufacturer's wiring specifications forLED Control Info.

Proximity Reader

BSHIELD

SHIELD

Diode (1N4004 or equiv.)for Counter EMFprotection

(see NOTE)

W3 Jumper

(Factory-set as shown)(Do not Change)

Transorb (Voltage Supression),Siemens S10K30 or equiv.

Diode (1N4004 or equiv.)for Counter EMFprotection

For a Stand-AloneSystem: Keep W2 jumper in TIN position.For a Multi-EMC System: refer to other side of sheet.

DoorSense A

L7

ActivityLight

L5

TamperSwitch

L6

N/A

L4

REX B

L2

REX A

L3

DoorSense B

EMC AddressDipswitching(EMCs must be sequentiallyaddressed starting withAddress 1)

(Top part of Front of Board)

RX TXTP3 +12V

TP4 +5V

W2Jumper

TOUT

TIN

EM3000Page 1For multi-EMC config.

instructions, refer toto the other side.

(Bottom part ofFront of Board) EMC 1

1540F1 Doc 6001540, Rev D

RS232-485 CONVERTER

A-

B+

RTN

GND

TB1+12V

+ 12V

GND

(B+)

(A-)

RTN

To PC Case Screw

One Conductor

From Second

Twisted Pair.

Other Conductor

Not Used.

A

One Twisted Pair

Attach Shield/Drain wireto any case screwon back of PC.

COMlocationwill vary

PORTRS-485

ConverterCOM

Red w/white stripeBlack

BATTERYBacked/Regulated1.0 Amp @ 12 VDC

Power Supply Board

GroundNeutral

Hot

GRNWHTBLK

To 110 VACat Junction Box orBreaker Panel

TB1

TB2

+IN-

+OUT-

Output

+ - CRedBlack

Low VoltageDisconnect Module

+-

Page 2: EM3000 QUICK INSTALLATION GUIDE - LiftMaster · (see detail) L1 RD 0 RD 1 P O W E R Door Strike ... RTN To PC Case Screw One Conductor ... the EMC boards must be addressed in order,

NOTE:See ReaderManufacturer'swiring specificationsfor LED control info.

1540F2

EMC 2

EMC 1 EMC 2EMC Address

Dipswitching For additionaladdressing, refer to theEM3000 InstallationManual.

OFF

ON

OFF

ON

(For a multi-EMC system,the EMC boards must beaddressed in order, startingwith Address 1).

EMC 1

OFF

ON

Page 2

EM3000

All except last EMC in amulti-EMC system.

Stand-alone; or last EMC in amulti-EMC system.

OFF

ON

to EMC 3and above

SHIELD

SHIELD SHIELD

SHIELD

RS-485 Connection

(see NOTE)

W3 Jumper

(Factory-set as shown)(Do not Change)

W3 Jumper

(Factory-set as shown)(Do not Change)

CABLING INFORMATION

Ref. Connection Conductors A.W.G Gauge Max ft.

A RS-485 Converter to last EMC 4* #24 4000** (1220 m)

B Proximity Reader to EMC 6 #22 500 (152 m)

C Door Strike to EMC 2 #18 500 (152 m)

D REX to EMC 2 #22 1000 (305 m)

E Door Status Contact 2 #22 500 (152 m)

-All cabling must be stranded with overall shielding.-Ground all (except RS-485) cable shield/drain wires to ground screw in cabinet. Follow open-ended grounding method (i.e., tape back shield/drain wire at other end).*One conductor not used from one of RS-485 twisted pairs.**End to end.

A

RS232-485 CONVERTER

A-

B+

RTN

GND

TB1+12V

+ 12V

GND

(B+)

(A-)

RTN

To PC Case Screw

One Conductor

From Second

Twisted Pair.

Other Conductor

Not Used.

A

One Twisted Pair

Attach Shield/Drainwire to any casescrew on backof PC.

COMlocationwill vary

PORTRS-485

Converter

Red w/white stripeBlack

BATTERYBacked/Regulated1.0 Amp @ 12 VDC

Power Supply Board

GroundNeutral

Hot

GRNWHTBLK

To 110 VACat Junction Box orBreaker Panel

TB1

TB2

+IN-

+OUT-

Output

+ - CRedBlack

Low VoltageDisconnect Module

+-

Red w/white stripeBlack

BATTERYBacked/Regulated1.0 Amp @ 12 VDC

Power Supply Board

GroundNeutral

Hot

GRNWHTBLK

To 110 VACat Junction Box orBreaker Panel

TB1

TB2

+IN-

+OUT-

Output

+ - CRedBlack

Low VoltageDisconnect Module

+-