Type ELK-AG-N up to 260 °C Advantages: Factory terminated High chemical and mechanical resistance Can be used in all industrial areas High working temperature Can be used in liquids Easy to install, even on complex shapes Highly flexible Resistant to steam purging This versatile heating cable is used for freeze protection and temperature maintenance, even under highly corrosive environmental conditions. The heating cable ELK-AG-N is suited and approved for use in potentially explosive atmospheres. It is highly flexible permitting its application in areas of use. Upon consultation of our engineers, this cable may likewise be used for inside trace heating of piping. factory terminated PTFE insulated heating cable 1.21 Applications, especially in hazardous areas: e.g. Heat tracing on tanks Heat tracing on vessels Heat tracing on filters Heat tracing on hoppers Pipes, valves and pumps Tank containers IBC’s Heating hoods Automotive Varnishing plants heating cables and heating tapes 1.21
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Type ELK-AG-N up to 260 °C
Advantages: Factory terminated High chemical and mechanical
resistance Can be used in all industrial areas High working temperature Can be used in liquids Easy to install, even on complex shapes Highly flexible Resistant to steam purging
This versatile heating cable is used for freeze protection and temperature maintenance, even under highly corrosive environmental conditions. The heating cable ELK-AG-N is suited and approved for use in potentially explosive atmospheres. It is highly flexible permitting its application in areas of use. Upon consultation of our engineers, this cable may likewise be used for inside trace heating of piping.
factory terminatedPTFE insulated heating cable
Heating cable und Heizbänder 1.21
Applications, especially in hazardous areas: e.g.
Heat tracing on tanks Heat tracing on vessels Heat tracing on filters Heat tracing on hoppers Pipes, valves and pumps Tank containers IBC’s Heating hoods Automotive Varnishing plants
heating cables and heating tapes 1.21
Dan Macey
TH1
03/2
012
– A
ll rig
hts
rese
rved
. Sub
ject
to c
hang
e w
ithou
t not
ice.
*Note: The output per meter of heating cable and the maximum possible working temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers – we will be pleased to advise you.
Manufactured according to DIN VDE 0253, EN 60079-30-1
Cables shall neither intersect nor contact. Provide protection by means of circuit breaker FI 30mA. Please observe the standards IEC 62395-2, EN 60519-10.