Top Banner
7/14/2019 Elkabel En http://slidepdf.com/reader/full/elkabel-en 1/430 No212257 Catalogue Cables and wires Catalogue Cables and wires    C   a    t   a    l   o   g   u   e    C   a    b    l   e   s   a   n    d   w    i   r   e   s
430

Elkabel En

Oct 29, 2015

Download

Documents

Dani Soumi
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 1/430

No 212257

Catalogue Cables and wires

Catalogue Cables and wires

C a t a l o g u e C a b l e s a n d w i r e s

Page 2: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 2/430

Page 3: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 3/430

Page 4: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 4/430

COMPANYís PROFILE

Elkabel Joint - Stock Company, with head-

quarters in Bourgas is the first Bulgarian

company specialized in the production of

cables and conductors.

It was established in 1947 on the basis of

several small-scale workshops for the pro-

duction of electrical products.

Today, Elkabel is the biggest manufacturer of

cables in Bulgaria, which has gone the way

of product and scope development and

extension in order more fully to response to

the high requirements of the market and to

the changing needs of different industrial sectors.

KEY DATES OF THE COMPANYHISTORY ARE:

- 1950. The first workshop for the production of

conductors was started up. The newly built

workshop for the production of flexible cables

with rubber insulation started operation.

- 1970. Workshop for low voltage power cables

with PVC insulation was started.

- 1975. A newly built workshop for the production

of telecommunication cables after the project of

the Italian company De Angeli, started up.

During the period 1979-1986 the production

of power cables with cross-linked polyethyl-

ene insulation started in accordance with the

license and equipment bought from Sumitomo

Electric including:

- two CCV lines cross linking in inert nitrogen

media- laboratory equipment for material and end prod-

uct quality control

- know-how for the production of cables

- In march 1995 Elkabel was the first company in

Bulgaria certified in accordance with ISO 9002

and since 1998 the company has been re-certi-

fied by Bureau Veritas Quality International

accordingly to the requirements of ISO 9001.

- Since 1998 Elkabel is the first privatized compa-

ny by the sale of shares on the Bulgarian Stock

Market. The management is carried out on two

levels: A Supervisory Council and A Board of

Directors.

Page 5: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 5/430

E L K A B E L

Elkabel spread across an area of 190 thou-

sand square meters with built up infrastruc-

ture. It is situated in close proximity to the Port

of Bourgas, the Duty Free Zone and the Air-

port.The plant has its own railway line and connec-

tion with E 773 Bourgas - Sofia.

Elkabel is well-known and respected manu-

facturer not only in Bulgaria but in the interna-

tional market as well. Its production is being

exported to Germany, UK, France, Belgium,

Hungary, Slovakia, Litva, Italy, Macedonia,

Albania, Cyprus, Egypt, Nigeria, Russia,

Ukraine, Uruguay, USA e.t.c.

THE PRODUCTION STRUCTUREincludes:

- production of copper and aluminium cores

- production of control and power cables with

insulation of PVC, PE and XLPE, armoured

and unarmoured

- production of power cables for rated voltage

up to 110 kV

- production of telecommunication cables with

paper, styroflex and plastic insulation

- production of copper and aluminium bareconductors

- laboratory for in-coming and end control of

materials and products

- accredited testing laboratory

THE PRODUCTION PROGRAMcomprises the following group of cables:

POWER CABLES

1.Power cables for rated voltage up to 1 kV,

insulated with PVC, manufactured to VDE,

BS, BDS, IEC and others. They are used forfixed installation in electrical systems and

for transfer and distribution of energy. Cores

can be copper and aluminium. Outer

sheaths are of PVC or PE depending of the

requirements of the standard and client.

Cables are manufactured with an option to

be with or without armour.

2.Power cables for medium and high voltage

with XLPE insulation, for voltage rate 3,6/6,

6/10, 12/20, 20/35 and 64/110 kV. They are

manufactured to BDS, IEC, BS, VDE. These

types of cables are manufactured in accord-

ance with a license and equipment bought

from Sumitomo Electric - Japan. The cores

can be copper and aluminium, outer

sheaths - PVC or PE. Cables are manufac-tured with option - with or without armour.

3.Control Cables - with PVC insulation, manu-

factured to VDE, BS, BDS, IEC and other.

4. Power cables for overhead lines transmis-

sion up to 1 kV, manufactured to NFC, VDE,

BDS.

The changes in the market and customer

requirements imposed all types of cables to

be manufactured also with an option of water-

resistance with longitudinal and cross water

resistance, incombustible and halogen-free,

with low emission of emitted gasses etc.

TELECOMMUNICATION CABLES

1.Low frequency telecommunication cables,

PE insulated, for urban telephone networks,

copper conductors with D 0.4, 0.5, 0.6 mm,

armoured and unarmoured.

2.Low frequency telecommunication cables,

PE insulated, jelly filed for guarantee of lon-gitudinal water protection of cables, for

urban telephone networks.

3.High frequency telecommunication cables,

paper and styroflex insulated, manufactured

to BDS and GOST

4.Combined telecommunication cables

TESTSElkabel has a laboratory accredited by the

Executive Agency ìBulgarian Accreditation

Sedviceî and ìRvAî - Nitherlands, to carry outindependent tests and parameter control of

power, telecommunication and rubber cables.

It is equipped with up-dated equipment.

The latest acquisition is a new high voltage

laboratory for long-lasting cable tests.

PRODUCTION CAPACITYCopper cores - 6,000 tons

Aluminium cores - 6,000 tons

Power cables - 18,000 tons

Telecommunication cables - 1500 tons

Page 6: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 6/430

5E L KA B E L

1. POWER CABLES

LOW VOLTAGE POWER CABLES

WITH PVC INSULATION . . . . . . . . . . . . . .9

NYM-0; NYM-J . . . . . . . . . . . . . . . . . . . . . .10

NYY-0 NYY-J . . . . . . . . . . . . . . . . . . . . . . .11

NYY-0; NYY-J . . . . . . . . . . . . . . . . . . . . . .12

NAYY-0; NAYY-J . . . . . . . . . . . . . . . . . . . .14

(N)AYY-0; (N)AYY-J . . . . . . . . . . . . . . . . . .16

(N)AY2Y-0; (N)AY2Y-J . . . . . . . . . . . . . . . .18

E-YY-0 E-YY-J . . . . . . . . . . . . . . . . . . . . . .20

E-AY2Y-0 E-AY2Y-J . . . . . . . . . . . . . . . . . .21

AYY-0; AYY-J . . . . . . . . . . . . . . . . . . . . . .22SZAMKAM . . . . . . . . . . . . . . . . . . . . . . . .23

NYCY . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

NAYCY . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

NYCY . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

YBY-0; YBY-J . . . . . . . . . . . . . . . . . . . . . .30

AYBY-0; AYBY-J . . . . . . . . . . . . . . . . . . . .32

PVC/SWA/PVC . . . . . . . . . . . . . . . . . . . . .34

LOW VOLTAGE POWER CABLES

WITH XLPE INSULATION . . . . . . . . . . . .35

2XY-0; 2XY-J . . . . . . . . . . . . . . . . . . . . . . .36

¿2XY-0; ¿2XY-J . . . . . . . . . . . . . . . . . . . .37

2XYRaY; A2XYRaY . . . . . . . . . . . . . . . . .38

2XYRY-0/J; A2XYRY-0/J . . . . . . . . . . . . . .40

N2XY-0/J . . . . . . . . . . . . . . . . . . . . . . . . . .42

N¿2XY-0; N¿2XY-J . . . . . . . . . . . . . . . . . .44

U 1000 R2V; U 1000 AR2V . . . . . . . . . . . . .46

EXVB . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50Cu/XLPE/PVC . . . . . . . . . . . . . . . . . . . . . .51

Cu/XLPE/PVC/SWA/PVC . . . . . . . . . . . . .52

Cu/XLPE/PVC/AWA/PVC . . . . . . . . . . . . .54

POWER CABLES FOR

OVERHEAD LINES . . . . . . . . . . . . . . . . . .55

NFA2X //; S¿H - VŒ . . . . . . . . . . . . . . . . .56

S¿H - VŒ . . . . . . . . . . . . . . . . . . . . . . . . . .58

Al/R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60SAH-20//SAX; SAHv-20 . . . . . . . . . . . . . . .62

MIDDLE VOLTAGEPOWER CABLES . . . . . . . . . . . . . . . . . . .64

2XSY/N2XSY; A2XSY/NA2XSY . . . . . . . . . . . .66

2XS2Y/N2XS2Y; A2XS2Y/NA2XS2Y . . . . . . . .682XS2Y-TRIPLEX/N2XS2Y-TRIPLEX;

A2XS2Y-TRIPLEX/NA2XS2Y-TRIPLEX . . . . . .70

2XS(F)2Y/N2XS(F)2Y;

A2XS(F)2Y/NA2XS(F)2Y . . . . . . . . . . . . . . . . .72

2XS(F)2Y-TRIPLEX /N2XS(F)2Y -TRIPLEX;

A2XS(F)2Y-TRIPLEX/NA2XS(F)2Y-TRIPLEX . .74

2XS(FL)2Y/N2XS(FL)2Y;

A2XS(FL)2Y/NA2XS(FL)2Y . . . . . . . . . . . . . . .76

2XS(FL)2Y-TRIPLEX/N2XS(FL)2Y-TRIPLEX; A2XS(FL)2Y -TRIPLEX/NA2XS(FL)2Y-TRIPLEX . .78

2XS≈Y/N2XS≈Y;

A2XS≈Y/NA2XS≈Y . . . . . . . . . . . . . . . . . . . . .80

2XS≈2Y/N2XS≈2Y;

A2XS≈2Y/NA2XS≈2Y . . . . . . . . . . . . . . . . . . .82

2XS≈(F)2Y/(N)2XS≈(F)2Y;

A2XS≈(F)2Y/(N)A2XS≈(F)2Y . . . . . . . . . . . . . .84

2XS≈(FL)2Y/(N)2XS≈(FL)2Y;

A2XS≈(FL)2Y/(N)A2XS≈(FL)2Y . . . . . . . . . . . .86

2XSY; A2XSY . . . . . . . . . . . . . . . . . . . . . . . . .88

2XS2Y; A2XS2Y . . . . . . . . . . . . . . . . . . . . . . . .90

2XS(F)2Y; A2XS(F)2Y . . . . . . . . . . . . . . . . . . .92

2XS(FL)2Y; A2XS(FL)2Y . . . . . . . . . . . . . . . . .94

2XS≈Y; A2XS≈Y . . . . . . . . . . . . . . . . . . . . . . .96

2XS≈2Y; A2XS≈2Y . . . . . . . . . . . . . . . . . . . . .98

2XS≈(F)2Y; A2XS≈(F)2Y . . . . . . . . . . . . . . .100

2XS≈(FL)2Y A2XS≈(FL)2Y . . . . . . . . . . . . .102

2XSEYBY; A2XSEYBY . . . . . . . . . . . . . . . . . .104

2XSEYB2Y; A2XSEYB2Y . . . . . . . . . . . . . . . .106

2XSE(F)2YB2Y/2XSE(F)2YBY;

A2XSE(F)2YB2Y/A2XSE(F)2YBY . . . . . . . . . .108

2XSEYBY; A2XSEYBY . . . . . . . . . . . . . . . . . .110

2XSEYB2Y; A2XSEYB2Y . . . . . . . . . . . . . . . .112

2XSE(F)2YB2Y/2XSE(F)2YBY;

A2XSE(F)2YB2Y/A2XSE(F)2YBY . . . . . . . . . .114

A2XS(F)2YT; A2XS2YT . . . . . . . . . . . . . . . . .116Cu/XLPE/CTS/PVC/AWA/PVC;

Page 7: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 7/430

6 E L KA B E L

Al/XLPE/CTS/PVC/AWA/PVC . . . . . . . . . . . .118

Cu/XLPE/CTS/PVC/SWA/PVC;

Al/XLPE/CTS/PVC/SWA/PVC . . . . . . . . . . . .120

Cu/XLPE/CWS/PE; Al/XLPE/CWS/PE . . . . .122Cu/XLPE/CWS/PE - TRIPLEX;

Al/XLPE/CWS/PE - TRIPLEX . . . . . . . . . . . .124

Cu/XLPE/CWS/PE-wb;

Al/XLPE/CWS/PE-wb . . . . . . . . . . . . . . . . . .126

CuwXLPE/CWS/PE-wb

AlwXLPE/CWS/PE-wb . . . . . . . . . . . . . . . . . .128

EVAVB; EVAVB-F2 . . . . . . . . . . . . . . . . . . . .130

EXeCWB; EAXeCWB . . . . . . . . . . . . . . . . . .132

EXeCVB; EAXeCVB . . . . . . . . . . . . . . . . . . .134

HIGH VOLTAGE POWER CABLES . . .136

2XS(F)2Y; A2XS(F)2Y . . . . . . . . . . . . . . . .138

A2XSY 1ı50rm/16 ELFILT . . . . . . . . . . . .140

A2XSY 1ı50rm/16 ELFILT . . . . . . . . . . . .141

POWER CABLES,

FLAME RETARDANT . . . . . . . . . . . . . .142

NYYfr-0/J . . . . . . . . . . . . . . . . . . . . . . . . .144

NYCY - FR . . . . . . . . . . . . . . . . . . . . . . . .146FG70R . . . . . . . . . . . . . . . . . . . . . . . . . . .148

2XYRYfr-0/J; A2XYRYfr-0/J . . . . . . . . . . .150

2XYRaY- FR; A2XYRaY-FR . . . . . . . . . . .152

2XSEY- FR; A2XSEY-FR . . . . . . . . . . . . .153

2XSEYBY- FR; A2XSEYBY - FR . . . . . . . .154

2XSYRaY- FR; A2XSYRaY- FR . . . . . . . .155

EVAVB-F2 . . . . . . . . . . . . . . . . . . . . . . . .156

LOW VOLTAGE POWER CABLES

HALOGEN FREE, FLAME RETARDANT . .158

NHXMH-0; NHXMH-J . . . . . . . . . . . . . . .158

(N)HXH-FE 180 . . . . . . . . . . . . . . . . . . . .160

N2XH-0/J . . . . . . . . . . . . . . . . . . . . . . . . .162

N2XSH; NA2XSH . . . . . . . . . . . . . . . . . . .164

N2XSEH; NA2XSEH . . . . . . . . . . . . . . . . .166

Cu/XLPE/LSF/SWA/LSF . . . . . . . . . . . . .168

Cu/XLPE/LSF/AWA/LSF . . . . . . . . . . . . .170

Cu/XLPE/CTS/LSF/AWA/LSF . . . . . . . . .171N2X—H . . . . . . . . . . . . . . . . . . . . . . . . . . .172

2XBH/¿2XBH . . . . . . . . . . . . . . . . . . . . . .174

2XSsH/(N)2XSsH; 2XSH/(N)2XSH . . . . .176

Cu/XLPE/CTS/LSF/SWA/LSF . . . . . . . . .177

2. TELE—OMMUNICATIONCABLESCOMMUNICATION CABLES FOR

LONG DISTANCES . . . . . . . . . . . . . . . .178

¿-PMZ . . . . . . . . . . . . . . . . . . . . . . . . . . .180

¿-PMZBC . . . . . . . . . . . . . . . . . . . . . . . . .182

COMMUNICATION CABLES FOR LOCAL

NETWORKS . . . . . . . . . . . . . . . . . . . . .184

A-2YF(L)2Y . . . . . . . . . . . . . . . . . . . . . . . .184 A-2Y(L)2Y . . . . . . . . . . . . . . . . . . . . . . . . .186

INSTALLATION CABLES FOR

TELECOMMUNICATIONS SYSTEMS .188

J-Y(St)Y . . . . . . . . . . . . . . . . . . . . . . . . . .188

FLEXIBLE CABLES FOR INDUSTRIAL

ELECTRONICS . . . . . . . . . . . . . . . . . . . .190

LiYY . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190

LiYCY . . . . . . . . . . . . . . . . . . . . . . . . . . . .194

LiYY-fr . . . . . . . . . . . . . . . . . . . . . . . . . . .198LiYCY-fr . . . . . . . . . . . . . . . . . . . . . . . . . .204

INSTRUMENTATION AND CONTROL

CABLES . . . . . . . . . . . . . . . . . . . . . . . .208

RE-2Y(St)Y . . . . . . . . . . . . . . . . . . . . . . . .208

RD-Y(St)Y . . . . . . . . . . . . . . . . . . . . . . . . .210

RE-2Y(St)Y-fl . . . . . . . . . . . . . . . . . . . . . .212

RE-2Y(St)Y-fl PiMF . . . . . . . . . . . . . . . . . .214

RE-2Y(St)YSWAY-fl . . . . . . . . . . . . . . . . .216

RE-2Y(St)YSWAY-fl - PiMF . . . . . . . . . . .218

RE-2X(St)Y -fr . . . . . . . . . . . . . . . . . . . . . .220

RE-2X(St)Y - fr PiMF . . . . . . . . . . . . . . . .222

PVC/PVC . . . . . . . . . . . . . . . . . . . . . . . . .224

PVC/SWA/PVC . . . . . . . . . . . . . . . . . . . .226

—OMMUNICATION AND

CONTROL CABLE . . . . . . . . . . . . . . . .228

PVC/PVC/SWA/PVC . . . . . . . . . . . . . . . .228

PVC/PVC/SWA/HDPE . . . . . . . . . . . . . . .234PVC/OSCR/PVC/SWA/PVC . . . . . . . . . .236

Page 8: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 8/430

7E L KA B E L

HALOGEN - FREE COMUNICATION AND

CONTROL CABLE . . . . . . . . . . . . . . . . .238

LSZH/LSZH . . . . . . . . . . . . . . . . . . . . . . .238

LSZH/LSZH/SWA/LSZH . . . . . . . . . . . . .242LSZH/ŒSCR/LSZH/SWA/LSZH . . . . . . .246

JE-HCH ...x2x0.8 BD . . . . . . . . . . . . . . . .248

JE-LiHCH ...x2x0.5mm2 . . . . . . . . . . . . . .249

CONTROL CABLE FOR INDUCED

VOLTAGE UP TO 5KV . . . . . . . . . . . . . .250

PE/PE/SWA/PE ...x2x1/0.8 . . . . . . . . . . .250

PE/PE/SWA/PVC . . . . . . . . . . . . . . . . . .254

PE/PJF/PE/SWA/PVC ...x2x1/0.8 . . . . . .258LOOP FEEDER CABLES . . . . . . . . . . .260

PE/PE . . . . . . . . . . . . . . . . . . . . . . . . . . .260

PE/SWA/PE . . . . . . . . . . . . . . . . . . . . . .261

3. CONDUCTORS

CONDUCTORS FOR ELECTRIC

INSTALLATIONS . . . . . . . . . . . . . . . . . .262

H05V-U/-K . . . . . . . . . . . . . . . . . . . . . . . .264

H07V-U/-R/-K . . . . . . . . . . . . . . . . . . . . . .265

NYIFY . . . . . . . . . . . . . . . . . . . . . . . . . . . .267

CONDUCTORS FOR

ELECTRIC APPLIANCES . . . . . . . . . . . .268

H03VV-F; H03VVH2-F . . . . . . . . . . . . . . .268

H05VV-F; H05VVH2-F . . . . . . . . . . . . . . .269

H05RR-F . . . . . . . . . . . . . . . . . . . . . . . . . .270

OIL RESISTANT PVC SHEATED

CONDUCTORS . . . . . . . . . . . . . . . . . . .272

H05VV5-F . . . . . . . . . . . . . . . . . . . . . . . . .272

H05VVC4V5-K . . . . . . . . . . . . . . . . . . . . .274

OPVC-JZ-CY . . . . . . . . . . . . . . . . . . . . . .276

OPVC - JZ . . . . . . . . . . . . . . . . . . . . . . . .278

CONDUCTORS FOR ELECTRIC

INSTALLATIONS WITH LOW EMISSION

OF SMOKE AND CORROSIVE GASES

WHEN AFFECTED BY FARE . . . . . . . . .280H07Z-U/R/K . . . . . . . . . . . . . . . . . . . . . . .280

4. BARE STRANDEDCONDUCTORS

MULTIWIRE CONDUCTORS . . . . . . . . .282

Multiwire copper and

aluminium conductors class 2 . . . . . . . .282

Multiwire copper conductors class 4 . . .283

Multiwire copper conductors class 5 . . .284

Multiwire copper conductors class 6 . . .285

BARE COPPER CONDUCTORS FOR

OVERHEAD LINES . . . . . . . . . . . . . . . .286

Bare copper conductors . . . . . . . . . . . . .286

Bare copper conductors . . . . . . . . . . . . .287BARE ALUMINIUMCONDUCTORS

AND ALUMINIUM CONDUCTORS,

STEEL-REINFORCED FOR

OVERHEAD LINES . . . . . . . . . . . . . . . .288

Bare aluminium conductors and

aluminum conductors, steel reinforced .288

Bare aluminium stranded conductors . . .289

Bare aluminium conductors,

steel reinforced . . . . . . . . . . . . . . . . . . . .290Bare aluminium conductors . . . . . . . . . .291

Bare aluminium and aluminium

steel reinforced stranded conductors . . .292

Bare aluminium conductors and aluminum

conductors, steel reinforced . . . . . . . . . .294

5. CABLES AND WIRES ACCORDING TO BDSSVT . . . . . . . . . . . . . . . . . . . . . . . . . . . . .296

SVT-s . . . . . . . . . . . . . . . . . . . . . . . . . . .298

SAVT . . . . . . . . . . . . . . . . . . . . . . . . . . . .300

SVTT . . . . . . . . . . . . . . . . . . . . . . . . . . . .302

SAVTT . . . . . . . . . . . . . . . . . . . . . . . . . . .304

SVBT . . . . . . . . . . . . . . . . . . . . . . . . . . . .306

SAVBT . . . . . . . . . . . . . . . . . . . . . . . . . . .308

SVOBT . . . . . . . . . . . . . . . . . . . . . . . . . . .310

SAPEmT-et 312

SAHEmT- et 313SHEkT . . . . . . . . . . . . . . . . . . . . . . . . . . .314

Page 9: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 9/430

8 E L KA B E L

SAHEkT . . . . . . . . . . . . . . . . . . . . . . . . .314

SHEk(vn)P . . . . . . . . . . . . . . . . . . . . . . .316

SAHEk(vn)P . . . . . . . . . . . . . . . . . . . . . .316

SHEk(v)P . . . . . . . . . . . . . . . . . . . . . . . .318SAHEk(v)P . . . . . . . . . . . . . . . . . . . . . . .318

SvHEk(v)P . . . . . . . . . . . . . . . . . . . . . . . .320

SAvHEk(v)P . . . . . . . . . . . . . . . . . . . . . .320

SHEa(v)P . . . . . . . . . . . . . . . . . . . . . . . .322

SAHEa(v)P . . . . . . . . . . . . . . . . . . . . . . .322

SHEmeT . . . . . . . . . . . . . . . . . . . . . . . . .324

SAHEmeT . . . . . . . . . . . . . . . . . . . . . . . .324

SVBT SAVBT . . . . . . . . . . . . . . . . . . . . .326

SVVn/A . . . . . . . . . . . . . . . . . . . . . . . . . .328SVVn/A . . . . . . . . . . . . . . . . . . . . . . . . . .330

SVVn/C . . . . . . . . . . . . . . . . . . . . . . . . . .332

SAVVn/¿ . . . . . . . . . . . . . . . . . . . . . . . . .334

SVBVn/A . . . . . . . . . . . . . . . . . . . . . . . . .336

SVBVn/A . . . . . . . . . . . . . . . . . . . . . . . . .338

SAVBVn/A . . . . . . . . . . . . . . . . . . . . . . . .340

MKG . . . . . . . . . . . . . . . . . . . . . . . . . . . . .342

MKBs . . . . . . . . . . . . . . . . . . . . . . . . . . . .343

MKBP . . . . . . . . . . . . . . . . . . . . . . . . . . . .344

MKEmPBP . . . . . . . . . . . . . . . . . . . . . . . .345

MKKG . . . . . . . . . . . . . . . . . . . . . . . . . . .346

MKKBs . . . . . . . . . . . . . . . . . . . . . . . . . .347

MKKBP . . . . . . . . . . . . . . . . . . . . . . . . . .348

MKKEmPBP . . . . . . . . . . . . . . . . . . . . . . .349

MKKEmPBPj . . . . . . . . . . . . . . . . . . . . . .350

TZG . . . . . . . . . . . . . . . . . . . . . . . . . . . . .352

TZBs . . . . . . . . . . . . . . . . . . . . . . . . . . . .354

TZBP . . . . . . . . . . . . . . . . . . . . . . . . . . . .356

TZEmPBP . . . . . . . . . . . . . . . . . . . . . . . .358

TZEmPBPe . . . . . . . . . . . . . . . . . . . . . . . .360

TPP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .362

TPPP . . . . . . . . . . . . . . . . . . . . . . . . . . . .364

TPPV . . . . . . . . . . . . . . . . . . . . . . . . . . . .366

TPPBP . . . . . . . . . . . . . . . . . . . . . . . . . . .368

TPPBPe . . . . . . . . . . . . . . . . . . . . . . . . . .370

TPJP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .372TPJPBP . . . . . . . . . . . . . . . . . . . . . . . . . .374

TPJPP . . . . . . . . . . . . . . . . . . . . . . . . . . .376

PPVR . . . . . . . . . . . . . . . . . . . . . . . . . . . .378

PPVAR . . . . . . . . . . . . . . . . . . . . . . . . . .379

PMVSUR . . . . . . . . . . . . . . . . . . . . . . . . .380PMVS . . . . . . . . . . . . . . . . . . . . . . . . . . . .380

PTPV . . . . . . . . . . . . . . . . . . . . . . . . . . . .381

YV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382

TSV/¿/V . . . . . . . . . . . . . . . . . . . . . . . . . .384

PVU-¿1 . . . . . . . . . . . . . . . . . . . . . . . . . . .386

PVU-¿2 . . . . . . . . . . . . . . . . . . . . . . . . . . .387

PVV-¿3 . . . . . . . . . . . . . . . . . . . . . . . . . . .388

PVV-MB1 . . . . . . . . . . . . . . . . . . . . . . . . .390

PVOT-2 . . . . . . . . . . . . . . . . . . . . . . . . . . .391Cu/PVC/PVC . . . . . . . . . . . . . . . . . . . . . .392

PVO . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393

ShKPSS . . . . . . . . . . . . . . . . . . . . . . . . . .394

XYMM K35 . . . . . . . . . . . . . . . . . . . . . . . .395

SPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . .396

TECHNICAL

DATA . . . . . . . . . . . . . . . . . . . . . . . .397

Page 10: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 10/430

L O W

V O L T A G E

P O W E R C A

B L E S

W I T H P V C I N S U L A T I O

N

L O W

V O L T A G E

P O WE R C A B L E S

WI T H P V C

I N S U L A T I O

N

E L K A B E L

Page 11: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 11/430

Cable design

Construction Accordind to VDE 0250 part 204

Conductor solid or multi-strand Cu wires class 1

or 2 acc. VDE 0295 (IEC 60228)Insulation PVC type YI1 acc. VDE0207

Core identification according to VDE 0293

Inner sheat elastic or plastic filling compound

Sheat PVC type YM1 acc. VDE 0207

Color grey

Technical data

10

Application

NYM is used as power and control cable in static installations for indoor instsllations, on, in and under plaster and inthe air where mechanical damage is not anticipated.

L O W

V O L T A G E P O W E R C

A B L E

N Y M - 0 ; N Y M - J Uo/U - 300/500 V VDE 0250 part 204

Conductor resistanceat 20 ∞C

According to VDE 0295class 1 or 2 (IEC60228)

Max. conductortemperature 70 ∞C

Max. short circuit temperature 160 ∞C, not more than 5 sec

Rated voltage Uo/U 300/500 V

Test voltage AC - 2 kV 50 Hz

Bending radius, min. 6 x D cable

Flame test VDE 0472 part 804 class B(IEC 332 part 1)

Color coding

Single core - black or yellow/greenDouble core - blue and brown or yellow-green and black

Other constructions according to table

3- core 4- core 5- core Multiple core

brown,black,grey,

or

yellow/green, bluebrown

blue, brownblack, grey

or

yellow/green,brown,black, grey

blue, brown,black, grey,

blackor

yellow/green,blue, brown,black, grey

black with number markon cores

orblack with number mark

on cores andyellow/green core in the

outer cover

E L K A B E L

Cu conductors PVC insulation PVC sheath

Constructive data NYM-o/j 300/500 V

Number ofconductorsand nominalcross section

ShapeOuter

diameterapprox.

Cu weightapprox.

Cable weightapprox.

N x mm2 mm kg/km kg/km

Constructive data NYM-o/j 300/500 V

Number ofconductorsand nominal

cross section

ShapeOuter

diameterapprox.

Cu weightapprox.

Cable weightapprox.

N x mm2 mm kg/km kg/km

1 x 1,5 re 5,7 14 50

1 x 2,5 re 6,4 23 65

1 x 4,0 re 6,9 37 87

1 x 6,0 re 7,6 56 1101 x 10,0 re 8,7 94 165

1 x 16,0 rm 10,1 153 2372 x 1,5 re 9,3 28 140

2 x 2,5 re 10,5 46 175

2 x 4,0 re 11,9 75 2352 x 6,0 re 12,9 112 297

2 x 10,0 re 16,2 188 4872 x 16,0 rm 19,0 307 696

2 x 25,0 rm 22,7 485 1036

2 x 35,0 rm 25,8 673 13703 x 1,5 re 9,8 43 145

3 x 2,5 re 11,0 70 204

3 x 4,0 re 12,5 112 2793 x 6,0 re 13,8 168 364

3 x 10,0 re 16,7 282 571

3 x 16,0 rm 19,9 460 8493 x 25,0 rm 24,1 728 1270

3 x 35,0 rm 26,7 1010 1656

4 x 1,5 re 10,3 57 176

4 x 2,5 re 11,9 93 242

4 x 4,0 re 14,0 149 3524 x 6,0 re 15,2 223 454

4 x 10,0 re 18,2 376 7034 x 16,0 rm 21,8 614 1051

4 x 25,0 rm 26,6 970 16034 x 35,0 rm 29,3 1346 2059

5 x 1,5 re 10,9 71 207

5 x 2,5 re 12,6 116 2875 x 4,0 re 15,2 187 433

5 x 6,0 re 16,5 279 541

5 x 10,0 re 19,9 470 8445 x 16,0 rm 24,3 767 1268

5 x 25,0 rm 29,2 1213 1934

5 x 35,0 rm 32,4 1683 25367 x 1,5 re 11,8 100 250

7 x 2,5 re 14,0 163 366

10 x 1,5 re 14,9 142 40012 x 1,5 re 15,3 171 458

Note: Other core configuration and special constructions manufactured upon request. Cables with same construction may produced according to IEC 60502.

Page 12: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 12/430

11

N Y Y - 0 N Y Y - J Uo/U - 0.6/1 kV VDE 0276 part 627

Cu conductors PVC insulation PVC sheath

Cable construction

Construction According to VDE 0276 part 627

Conductor solid or multi-strand Cu wires class 1or 2 acc. VDE 0295 (IEC 60228)

Insulation PVC type DIV4 acc. VDE0207

Core identification according to VDE 0293

Inner sheath filling compound or tapes

Sheath PVC type DMV5 acc. VDE 0207

Color black

Technical data

Note: Other core configuration and special constructions manufactured upon request.Cables with same construction may produced according to IEC 60502.

Construction data NYY o/j 0.6/1 kV

Number of wires and

nominalcross sec-

tion

Shape

Outer dia-meter of

cableapprox.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

Construction data NYY o/j 0.6/1 kV

Number of wires and

nominalcross sec-

tion

Shape

Outer dia-meter of

cableapprox.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

7 x 1,5 re 14,7 100 3238 x 1,5 re 16,0 114 38510 x 1,5 re 17,7 142 47212 x 1,5 re 18,2 171 50914 x 1,5 re 19,0 199 55916 x 1,5 re 19,9 227 61719 x 1,5 re 20,8 270 68920 x 1,5 re 21,8 284 72921 x 1,5 re 21,8 299 75124 x 1,5 re 23,9 341 90425 x 1,5 re 24,5 355 96827 x 1,5 re 24,4 384 95430 x 1,5 re 25,3 426 103037 x 1,5 re 27,0 526 11957 x 2,5 re 15,8 163 4138 x 2,5 re 17,4 186 49310 x 2,5 re 19,3 232 609

12 x 2,5 re 19,8 279 66214 x 2,5 re 20,7 325 73316 x 2,5 re 21,7 372 80719 x 2,5 re 22,8 441 91620 x 2,5 re 23,9 464 96821 x 2,5 re 23,9 488 100124 x 2,5 re 26,2 557 120327 x 2,5 re 26,8 627 127830 x 2,5 re 27,8 697 138637 x 2,5 re 29,9 859 16417 x 4,0 re 19,3 261 6398 x 4,0 re 21,3 299 76610 x 4,0 re 23,8 373 95012 x 4,0 re 24,5 448 103514 x 4,0 re 25,6 522 114716 x 4,0 re 26,9 597 126519 x 4,0 re 28,2 709 1440

Conductor resistance at20∞—

According to VDE 0295class 1 or 2 (IEC 60228)

Max. conductortemperature +70∞—

Max. short circuittemperature

+160∞—, not more than 5sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 4 kV 50 Hz

Bending radius-single core-multi core

15 cable diameter12 cable diameter

Flame testVDE 0472 part 804 class B

(IEC 332 part 1)

Color coding

black with number mark on coresorblack with number mark on cores and yellow/green in theouter cover

Application

NYY is used in power plants industrial and switching installations, in secondary distribution networks and other.These cables arepreferentially used in outdoor applications, for indoor instalations, in the open air, underground and in water where mechanicalamage is not anticipated.

E L K A B E L

L O W

V O L T A G E C O N

T R O L C A B L E

Page 13: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 13/430

Application

NYY is used in power plants industrial and switching installations, in secondary distribution networks and other.Thesecables are preferentially used in outdoor applications, for indoor instalations, in the open air, underground and in waterwhere mechanical damage is not anticipated.

Cable design

Construction According to VDE 0276 part 603

Conductor solid or multi-strand Cu wires class 1or 2 acc. VDE 0295 (IEC 60228)

Insulation PVC type DIV4 acc. VDE0276

Core identification according to VDE 0293

Inner sheath filling compound

Sheath PVC type DMV5 acc. VDE 0276

Color black

Technical data

Color coding

Single core - black or yellow/green

Double core - blue and brown or yellow-green and black

Conductor resistance at20 ∞C

According to VDE 0295class 1 or 2 (IEC 60228)

Max. conductor tempera-ture 70 ∞C

Max. shortcircuit temperature 160 ∞C, not more than 5 sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 4 kV 50 Hz

Bending radius-single core-multi core

15 x D cable12 ı D cable

Temperature of exploita-tion -30 ∞C to +50 ∞C

Flame test VDE 0472 part 804 class B(IEC 332 part 1)

3- core 4- core 5- core Multiple core

brownblackgreyor

yellow/greenblue

brown

bluebrownblackgreyor

yellow/greenbrownblackgrey

bluebrown

blackgreyblackor

yellow/greenblue

brownblackgrey

black with number markon cores

orblack with number mark

on cores andyellow/green core in the

outer cover

12

L O W

V O L T A G E P O W E R C

A B L E

N Y Y - 0 ; N Y Y -J Uo/U - 0.6/1 kV VDE 0276 part 603

E L K A B E L

Page 14: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 14/430

13

L O W

V O L T A G E P O W

E R C A B L E

Constructive data NYY -o/j 0.6/1 kVNumber ofconductorsand nominalcross sec-

tion

Shape

Outercable

diameterapprox.

Copper weight

Cable weightapprox.

N x mm2 mm kg/km kg/km

Note: Other core configuration and special constructions manufac-

tured upon request. Cables with same construction may produced according to IEC 60502.

Cu conductors PVC insulation PVC sheath

Constructive data NYY -o/j 0.6/1 kVNumber ofconductorsand nominalcross sec-

tion

Shape

Outercable

diameterapprox.

Copper weight

Cable weightapprox.

N x mm2 mm kg/km kg/km

1 x 1,5 re 7,1 14 631 x 2,5 re 7,5 23 761 x 4,0 re 8,4 37 1041 x 6,0 re 8,9 56 1281 x 10,0 re 9,7 94 1831 x 16,0 re 10,7 149 2471 x 25,0 rm 12,7 243 3591 x 35,0 rm 13,9 337 4621 x 50,0 rm 15,4 454 6031 x 70,0 rm 17,1 656 8171 x 95,0 rm 19,4 911 10921 x 120,0 rm 20,8 1147 13341 x 150,0 rm 22,7 1415 1627

1 x 185,0 rm 25,0 1770 20131 x 240,0 rm 27,8 2327 25981 x 300,0 rm 30,7 2887 32001 x 400,0 rm 34,1 3692 40481 x 500,0 rm 38,1 4725 51412 x 1,5 re 12,2 28 1922 x 2,5 re 12,9 46 2292 x 4,0 re 14,9 75 3152 x 6,0 re 15,9 112 3822 x 10,0 re 17,5 188 5092 x 16,0 re 19,4 298 6762 x 25,0 rm 23,5 485 10272 x 35,0 rm 25,7 673 13012 x 50,0 rm 29,1 908 17032 x 70,0 rm 32,1 1312 2312

2 x 95,0 rm 38,0 1822 3093

3 x 1,5 re 12,1 43 2013 x 2,5 re 12,9 70 2473 x 4,0 re 15,0 112 3503 x 6,0 re 16,1 168 4353 x 10,0 re 18,0 282 6063 x 16,0 re 20,1 447 8283 x 25,0 rm 24,4 728 12603 x 35,0 rm 26,7 1010 16223 x 50,0 rm 30,4 1363 21393 x 70,0 sm 29,2 1968 23803 x 95,0 sm 33,2 2732 32333 x 120,0 sm 35,4 3440 3962

3 x 150,0 sm 39,2 4245 48673 x 185,0 sm 42,7 5311 60463 x 240,0 sm 48,1 6981 78693 x 300,0 sm 53,5 8661 9702

3 x 25,0+16 sm re 25,4 876 14223 x 35,0+16 sm re 27,7 1159 17903 x 50,0+25 sm rm 29,2 1605 20913 x 70,0+35 sm rm 33,4 2304 28203 x 95,0+50 sm rm 37,8 3187 38243 x 120,0+70 sm rm 40,8 4096 47793 x 150,0+70 sm rm 44,8 4901 56853 x 185,0+95 sm rm 49,3 6222 71633 x 240,0+120 sm rm 55,3 8128 9227

3 x 300,0+150 sm rm 60,9 10076 113634 x 1,5 re 12,9 57 2324 x 2,5 re 13,8 93 2894 x 4,0 re 16,2 149 4194 x 6,0 re 17,4 223 5254 x 10,0 re 19,5 376 7414 x 16,0 re 21,8 595 10244 x 25,0 rm 27,2 970 16154 x 35,0 rm 30,1 1346 20954 x 50,0 sm 29,2 1817 23114 x 70,0 sm 33,4 2624 31424 x 95,0 sm 37,8 3643 42814 x 120,0 sm 40,8 4587 52564 x 150,0 sm 44,8 5660 64424 x 185,0 sm 49,3 7082 8033

4 x 240,0 sm 55,3 9308 104264 x 300,0 sm 60,9 11548 12850

5 x 1,5 re 13,7 71 2725 x 2,5 re 14,8 116 3415 x 4,0 re 17,4 187 4945 x 6,0 re 19,0 279 6355 x 10,0 re 21,6 470 9115 x 16,0 re 24,1 744 12625 x 25,0 rm 29,9 1213 19645 x 35,0 rm 33,5 1683 25935 x 50,0 rm 38,1 2271 34355 x 70,0 rm 43,3 3280 46385 x 95,0 rm 50,1 4554 6318

E L K A B E L

Page 15: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 15/430

Cable construction

Construction According to VDE 0276 part 603

Conductor solid or multi-strand Al wires class 1or 2 acc. VDE 0295 (IEC 60228)

Insulation PVC type DIV4 acc. VDE0207

Core identification according to VDE 0293

Inner sheath filling compound

Sheath PVC type DMV5 acc. VDE 0207

Color black

Technical data

14

Application

NAYY is used in power plants industrial and switching installations, in secondary distribution networks and other.Thesecables are preferentially used in outdoor applications, for indoor instalations, in the open air, underground and in waterwhere mechanical damage is not anticipated.

L O W

V O L T A G E P O W E R C

A B L E

NAYY-0; NAYY-J Uo/U - 0.6/1 kV VDE 0276 part 603

Color coding

Single core - black or yellow/greenDouble core -blue and brown or yellow-green and black

3 - core 4 - core 5 - core Multiple core

brownblack

greyoryel-

low/greenblue

brown

bluebrownblack

greyoryellow/greenbrownblackgrey

bluebrownblackgrey

blackor

yellow/greenblue

brownblackgrey

black with number markon cores

orblack with number mark

on cores andyellow/green core in the

outer cover

Conductor resistance at20∞—

According to VDE 0295class 1 or 2 (IEC 60228)

Max. conductortemperature

+70∞—

Max. short circuittemperature

+160∞—, not more than 5sec

Rated voltage Uo/U 0.6/1 kVTest voltage AC - 4 kV 50 Hz

Bending radius-single core-multi core

15 cable diameter12 cable diameter

Flame testVDE 0472 part 804 class B

(IEC 332 part 1)

E L K A B E L

Page 16: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 16/430

15

L O W

V O L T A G E P O W

E R C A B L E

Al conductors PVC insulation PVC sheath

Note

Other core configuration and special constructions manufactured upon request.Cables with same construction may produced according to IEC 60502.

Construction data NAYY o/j 0.6/1 kV

Number of wires and

nominal

cross sec-tion

Shape

Outerdiameterof cable

approx.

Al weight

Cable weight

approx.

N ı mm2 mm kg/km kg/km

Construction data NAYY o/j 0.6/1 kV

Number of wires and

nominal

cross sec-tion

Shape

Outerdiameterof cable

approx.

Al weight

Cable weight

approx.

N ı mm2 mm kg/km kg/km

1x25,0 re 12,2 70 1901 x 35,0 re 13,1 97 2291 x 50,0 re 14,5 131 2881 x 50,0 rm 15,4 135 3031 x 70,0 rm 17,1 195 3851 x 95,0 rm 19,3 270 4991 x 120,0 rm 20,8 341 5891 x 150,0 rm 22,6 419 7051 x 185,0 rm 24,9 526 8621 x 240,0 rm 27,7 690 10831 x 300,0 rm 30,6 863 1325

1 x 400,0 rm 34,0 1109 16571 x 500,0 rm 38,0 1461 21722 x 25,0 re 22,4 140 6852 x 35,0 re 24,3 194 8262 x 50,0 re 27,3 261 10492 x 35,0 rm 25,4 199 8802 x 50,0 rm 29,1 269 11552 x 70,0 rm 33,1 390 14472 x 95,0 rm 37,9 539 19053 x 25,0 re 23,7 210 7683 x 35,0 re 25,8 291 9323 x 50,0 sm 30,9 404 12943 x 50,0 sm 27,8 404 9943 x 70,0 sm 31,2 584 12503 x 95,0 sm 35,8 809 16753 x 120,0 sm 38,0 1023 1964

3 x 150,0 sm 41,8 1257 23653 x 185,0 sm 45,7 1579 29133 x 240,0 sm 51,1 2071 3693

3 x 50,0+25 re+re 30,5 462 13103 x 50,0+25 sm+rm 31,2 474 11583 x 70,0+35 sm+rm 36,0 684 15373 x 95,0+50 sm+rm 40,2 944 19713 x 120,0+70 sm+rm 43,2 1218 23463 x 150,0+70 sm+rm 48,0 1452 28393 x 185,0+95 sm+rm 52,3 1848 34703 x 240,0+120 sm+rm 58,7 2412 43993 x 300,0+150 sm+rm 64,3 3008 5321

4 x 25,0 re 25,8 281 9124 x 35,0 re 28,2 388 11114 x 50,0 sm 31,2 539 12654 x 70,0 sm 36,0 779 16584 x 95,0 sm 40,2 1079 21394 x 120,0 sm 43,2 1364 25244 x 150,0 sm 48,0 1676 31234 x 185,0 sm 53,7 2105 40024 x 240,0 sm 58,7 2762 48484 x 300,0 sm 64,3 3452 58825 x 25,0 re 28,1 351 10725 x 35,0 re 30,9 485 13265 x 50,0 re 35,7 653 17715 x 25,0 rm 30,4 360 11835 x 35,0 rm 33,0 497 14565 x 50,0 rm 38,1 673 19195 x 70,0 rm 43,3 974 24525 x 95,0 rm 49,8 1349 3257

E L K A B E L

Page 17: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 17/430

Cable construction

Construction According to VDE 0276 part 603

Conductor solid or multi-strand Al wires class 1or 2 acc. VDE 0295 (IEC 60228)

Insulation PVC type DIV4 acc. VDE0207

Core identification according to VDE 0293

Sheath PVC type DMV5 acc. VDE 0207

Color black

Technical data

Color coding

Single core - black, or yellow/greenDouble core - black and blue or yellow-green and black

3 - core 4 - core 5 - core

brownblackgreyor

yellow/greenblue

brown

bluebrownblackgreyor

yellow/greenbrownblackgrey

bluebrownblackgreyblack

oryellow/green

bluebrownblackgrey

16

Application

(N)AYY is used in power plants industrial and switching installations, in secondary distribution networks andother.These cables are preferentially used in outdoor applications, for indoor instalations, in the open air, undergroundand in water where mechanical damage is not anticipated.

L O W

V O L T A G E P O W E R C

A B L E

(N )AYY -0

(N)AYY-J

Uo/U - 0.6/1 kV VDE 0276 part 603

Conductor resistance at20∞—

According to VDE 0295class 1 or 2 (IEC 60228)

Max. conductortemperature

+70∞—

Max. short circuit

temperature

+160∞—, not more than 5

sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 4 kV 50 Hz

Bending radius-single core-multi core

15 cable diameter12 cable diameter

Flame testVDE 0472 part 804 class B

(IEC 332 part 1)

E L K A B E L

Page 18: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 18/430

17

L O W

V O L T A G E P O W

E R C A B L E

Al conductors PVC insulation PVC sheath

Note

Other core configuration and special constructions manufactured upon request.

Cables with same construction may produced according to IEC 60502.

Construction data (N)AYY o/j 0.6/1 kV

Number of wires and

nominal

cross sec-tion

Shape

Outerdiameterof cable

approx.

Al weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

Construction data (N)AYY o/j 0.6/1 kV

Number of wires and

nominal

cross sec-tion

Shape

Outerdiameterof cable

approx.

Al weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

1 x 25,0 re 11,5 70 1901 x 35,0 re 12,5 97 2291 x 50,0 re 13,9 131 2881 x 50,0 rm 15,1 135 3031 x 70,0 rm 16,1 195 3851 x 95,0 rm 18,2 270 499

1 x 120,0 rm 20,0 341 5891 x 150,0 rm 22,0 419 7051 x 185,0 rm 24,1 526 8621 x 240,0 rm 27,1 690 10831 x 300,0 rm 29,1 863 13251 x 400,0 rm 33,1 1109 1657

1 x 500,0 rm 37,1 1461 21722 x 25,0 re 20,4 140 391,52 x 35,0 re 22,3 194 472,62 x 50,0 re 25,3 261 594,82 x 35,0 rm 23,4 199 490,82 x 50,0 rm 26,5 269 657,22 x 70,0 rm 30,0 390 961,72 x 95,0 rm 34,6 539 1269,03 x 25,0 re 21,7 210 587,63 x 35,0 re 23,6 291 715,83 x 50,0 re 26,8 392 922,33 x 50,0 sm 25,8 404 913,53 x 70,0 sm 29,2 584 1157,93 x 95,0 sm 33,8 809 1554,2

3 x 120,0 sm 36,0 1023 1835,5

3 x 150,0 sm 39,8 1257 2222,53 x 185,0 sm 43,1 1579 2717,4

3 x 240,0 sm 48,2 2071 3474,03 x 50,0+25 re+re 28,0 462 9863 x 50,0+25 sm+rm 31,2 474 1068,0

3 x 70,0+35 sm+rm 36,0 684 1417,93 x 95,0+50 sm+rm 40,2 944 1836,2

3 x 120,0+70 sm+rm 43,2 1218 2162,73 x 150,0+70 sm+rm 48,0 1452 2637,33 x 185,0+95 sm+rm 52,3 1848 3248,3

3 x 240,0+120 sm+rm 58,7 2412 4124,23 x 300,0+150 sm+rm 64,3 3008 5018,0

4 x 25,0 re 23,8 281 609,84 x 35,0 re 26,2 388 753,5

4 x 50,0 re 29,8 522 1032,04 x 50,0 sm 29,2 539 1170,84 x 70,0 sm 33,6 779 1527,44 x 95,0 sm 38,2 1079 1991,4

4 x 120,0 sm 41,2 1364 2337,34 x 150,0 sm 45,2 1676 2917,54 x 185,0 sm 49,6 2105 3776,84 x 240,0 sm 55,7 2762 4558,24 x 300,0 sm 61,3 3452 5562,85 x 25,0 re 26,1 351 885,65 x 35,0 re 28,9 485 1033,85 x 50,0 re 32,8 653 1376,15 x 25,0 rm 27,4 360 981,05 x 35,0 rm 30,4 497 1194,15 x 50,0 rm 34,6 673 1586,5

5 x 70,0 rm 39,2 974 1997,95 x 95,0 rm 45,2 1349 2672,2

E L K A B E L

Page 19: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 19/430

Cable construction

Construction According to VDE 0276 part 603

Conductor solid or multi-strand Al wires class 1or 2 acc. VDE 0295 (IEC 60228)

Insulation PVC type DIV4 acc. VDE0276

Core identification according to VDE 0293

Sheath PE type DMP 2 acc. VDE 0276

Color black

Technical data

Color coding

Single core - black, or yellow/greenDouble core - light blue and brown or yellow-green andblack

Conductor resistance at20∞—

According to VDE 0295class 1 or 2 (IEC 60228)

Max. conductortemperature

+70∞—

Max. short circuit

temperature

+160∞—, not more than 5

sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 4 kV 50 Hz

Bending radius-single core-multi core

15 cable diameter12 cable diameter

18

Application

(N)AY2Y is used in power plants industrial and switching installations, in secondary distribution networks andother.These cables are preferentially used in outdoor applications, for indoor instalations, in the open air, undergroundand in water where mechanical damage is not anticipated.

L O W

V O L T A G E P O W E R C

A B L E

(N )AY2Y -0

(N )AY2Y -J

Uo/U - 0.6/1 kVSimilar to VDE 0276 part 603

3 - core 4 - core 5 - core

brownblackgreyor

yellow/greenlight blue

brown

light bluebrownblackgreyor

yellow/greenbrownblackgrey

light bluebrownblackgreyblack

oryellow/green

light bluebrownblackgrey

E L K A B E L

Page 20: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 20/430

19

L O W

V O L T A G E P O W

E R C A B L E

Al conductors PVC insulation PE sheath

Note

Other core configuration and special constructions manufactured upon request.Cables with same construction may produced according to IEC 60502.

Construction data (N)AY2Y o/j 0.6/1 kV

Number of

wires andnominalcross sec-

tion

Shape

Outer

diameterof cableapprox.

Al weight

Cable

weightapprox.

N ı mm2 mm kg/km kg/km

Construction data (N)AY2Y o/j 0.6/1 kV

Number of

wires andnominalcross sec-

tion

Shape

Outer

diameterof cableapprox.

Al weight

Cable

weightapprox.

N ı mm2 mm kg/km kg/km

1 x 25,0 re 11,5 70 1591 x 35,0 re 12,5 97 1951 x 50,0 re 13,9 131 2491 x 50,0 rm 15,1 135 2551 x 70,0 rm 16,1 195 3391 x 95,0 rm 18,2 270 447

1 x 120,0 rm 20,0 341 5251 x 150,0 rm 22,0 419 6311 x 185,0 rm 24,1 526 780,1 x 240,0 rm 27,1 690 986

1 x 300,0 rm 29,1 863 12331 x 400,0 rm 33,1 1109 15311 x 500,0 rm 37,1 1461 20192 x 25,0 re 20,4 140 2762 x 35,0 re 22,3 194 3462 x 50,0 re 25,3 261 4512 x 35,0 rm 23,4 199 3582 x 50,0 rm 26,5 269 5072 x 70,0 rm 30,0 390 7812 x 95,0 rm 34,6 539 10453 x 25,0 re 21,7 210 4753 x 35,0 re 23,6 291 5853 x 50,0 re 26,8 392 7633 x 50,0 sm 25,8 404 8393 x 70,0 sm 29,2 584 10663 x 95,0 sm 33,8 809 1441

3 x 120,0 sm 36,0 1023 17103 x 150,0 sm 39,8 1257 20743 x 185,0 sm 43,1 1579 2546

3 x 240,0 sm 48,2 2071 32673 x 50,0+25 re+re 28,0 462 9403 x 50,0+25 sm+rm 31,2 474 10033 x 70,0+35 sm+rm 36,0 684 13373 x 95,0+50 sm+rm 40,2 944 1738

3 x 120,0+70 sm+rm 43,2 1218 20503 x 150,0+70 sm+rm 48,0 1452 25093 x 185,0+95 sm+rm 52,3 1848 3096

3 x 240,0+120 sm+rm 58,7 2412 39393 x 300,0+150 sm+rm 64,3 3008 4801

4 x 25,0 re 23,8 281 6814 x 35,0 re 26,2 388 8324 x 50,0 re 29,8 522 11294 x 50,0 sm 29,2 539 10814 x 70,0 sm 33,6 779 14154 x 95,0 sm 38,2 1079 1855

4 x 120,0 sm 41,2 1364 21824 x 150,0 sm 45,2 1676 27364 x 185,0 sm 49,6 2105 35654 x 240,0 sm 55,7 2762 43004 x 300,0 sm 61,3 3452 52595 x 25,0 re 26,1 351 7505 x 35,0 re 28,9 485 10095 x 50,0 re 32,8 653 13525 x 25,0 rm 27,4 360 8365 x 35,0 rm 30,4 497 1094

5 x 50,0 rm 34,6 673 14635 x 70,0 rm 39,2 974 18465 x 95,0 rm 45,2 1349 2481

E L K A B E L

Page 21: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 21/430

Cable constructionConstruction According to HD 603 S1

Conductor solid or multi-strand Cu wires class 1or 2 acc. VDE 0295 (IEC 60228)

Insulation PVC type DIV1 acc. HD 603 S1

Core identification according to VDE 0293

Sheath PVC type DMV 1 acc. HD 603 S1

Color black

Technical data

Color coding

Single core - black, or yellow/greenDouble core - light blue and brown or yellow-green andblack

20

Application

E-YY is used in power plants industrial and switching installations, in secondary distribution networks and other.Thesecables are preferentially used in outdoor applications, for indoor instalations, in the open air, underground and in waterwhere mechanical damage is not anticipated.

L O W

V O L T A G E P O W E R C

A B L E

E-YY-0 E-YY-J Uo/U - 0.6/1 kVHD 603 S1 part 3A

Construction data E-YY o/j 0.6/1 kV

Number of wires and

nominal

cross sec-tion

Shape

Outerdiameterof cable

approx.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

Construction data E-YY o/j 0.6/1 kV

Number of wires and

nominal

cross sec-tion

Shape

Outerdiameterof cable

approx.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

3 x 1.5 re 11,6 43 2013 x 2.5 re 12,4 70 2473 x 4 re 13,5 112 3503 x 6 re 14,5 168 435

3 x 10 re 16,2 282 6063 x 16 re 11,6 447 828

3 x 50,0 sm 25,1 1363 21393 x 70,0 sm 29,2 1968 23803 x 95,0 sm 33,2 2732 3233

3 x 120,0 sm 35,4 3440 39623 x 150,0 sm 39,2 4245 48673 x 185,0 sm 42,7 5311 6046

3 x 240,0 sm 48,1 6981 78693 x 35,0+16 sm+rm 26,0 1159 17903 x 50,0+25 sm+rm 29,1 1605 2091

3 x 70,0+35 sm+rm 33,1 2304 28203 x 95,0+50 sm+rm 37,6 3187 3824

3 x 120,0+70 sm+rm 40,5 4096 47793 x 150,0+70 sm+rm 45,8 4901 56853 x 185,0+95 sm+rm 49,8 6222 7163

4 x 6,0 re 6,0 223 5254 x 10,0 re 17,5 376 7414 x 16,0 re 19,7 595 10245 x 1,5 re 13,7 71 2725 x 2,5 re 14,8 116 3415 x 4 re 15,7 187 4945 x 6 re 17,0 279 635

5 x 10 re 19,1 470 9115 x 16 re 21,6 744 1262

Cu conductors PVC insulation PVC sheath

Note: Other core configuration and special constructions manufactured upon request. Cables with same construction may produced according to IEC 60502.

Conductor resistance at20∞—

According to VDE 0295class 1 or 2 (IEC 60228)

Max. conductortemperature +70∞—

Max. short circuittemperature

+160∞—, not more than 5sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 4 kV 50 Hz

Bending radius-single core-multi core

15 cable diameter12 cable diameter

3 - core 4 - core 5 - core

brown/blackgreyor

yellow/greenlight

blue/brown

light blue/brownblack/grey

oryellow/greenbrown/black/

grey

light blue/brownblack/grey/

blackor

yellow/greenlight blue/brown

black/grey

E L K A B E L

Page 22: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 22/430

21

L O W

V O L T A G E P O W

E R C A B L E

Uo/U - 0.6/1 kVHD 603 S1 part 3A

Cable constructionConstruction According to VDE 0276 part 603

Conductor solid or multi-strand Al wires class 1or 2 acc. VDE 0295 (IEC 60228)

Insulation PVC type DIV1 acc. HD 603 S1

Core identification according to VDE 0293

Sheath PE type DMP 2 acc. VDE 0276

Color black

Technical data

Color codingSingle core - black, or yellow/greenDouble core - blue and brown or yellow-green and black

Construction data E-AY2Y o/j 0.6/1 kV

Number of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Al weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

Construction data E-AY2Y o/j 0.6/1 kV

Number of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Al weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

1 x 25,0 re 11,5 70 159

1 x 35,0 re 12,5 97 1951 x 50,0 re 13,9 131 2491 x 50,0 rm 15,1 135 2551 x 70,0 rm 16,1 195 3391 x 95,0 rm 18,2 270 447

1 x 120,0 rm 20,0 341 5251 x 150,0 rm 22,0 419 6311 x 185,0 rm 24,1 526 780,1 x 240,0 rm 27,1 690 9861 x 300,0 rm 29,1 863 12331 x 400,0 rm 33,1 1109 15311 x 500,0 rm 37,1 1461 20192 x 25,0 re 20,4 140 2762 x 35,0 re 22,3 194 3462 x 50,0 re 25,3 261 4512 x 35,0 rm 23,4 199 3582 x 50,0 rm 26,5 269 5072 x 70,0 rm 30,0 390 7812 x 95,0 rm 34,6 539 1045

3 x 25,0 re 21,7 210 475

3 x 35,0 re 23,6 291 5853 x 50,0 re 26,8 392 7633 x 50,0 sm 25,8 404 8393 x 70,0 sm 29,2 584 10663 x 95,0 sm 33,8 809 1441

3 x 120,0 sm 36,0 1023 17103 x 150,0 sm 39,8 1257 20743 x 185,0 sm 43,1 1579 25463 x 240,0 sm 48,2 2071 3267

3 x 50,0+25 re+re 28,0 462 9403 x 50,0+25 sm+rm 31,2 474 10033 x 70,0+35 sm+rm 36,0 684 13373 x 95,0+50 sm+rm 40,2 944 1738

3 x 120,0+70 sm+rm 43,2 1218 20503 x 150,0+70 sm+rm 48,0 1452 25093 x 185,0+95 sm+rm 52,3 1848 3096

3 x 240,0+120 sm+rm 58,7 2412 39393 x 300,0+150 sm+rm 64,3 3008 4801

Note: Other core configuration and special constructions manufactured upon request. Cables with same construction may produced according to IEC 60502.

Al conductors PVC insulation PE sheath

Conductor resistance at20∞—

According to VDE 0295class 1 or 2 (IEC 60228)

Max. conductortemperature +70∞—

Max. short circuittemperature

+160∞—, not more than 5sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 4 kV 50 Hz

Bending radius-single core-multi core

15 cable diameter12 cable diameter

3 - core 4 - core 5 - core

brown/blackgreyor

yellow/greenblue/brown

blue/brown/black/grey

oryellow/greenbrown/black/

grey

blue/brownblack/grey/

blackor

yellow/greenblue/brownblack/grey

Application

E-AY2Y is used in power plants industrial and switching installations, in secondary distribution networks andother.These cables are preferentially used in outdoor applications, for indoor instalations, in the open air, undergroundand in water where mechanical damage is not anticipated.

E L K A B E L

Page 23: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 23/430

Cable construction

Construction According to IEC 60502-1

Conductor solid or multi-strand Al wires class 1or 2 acc. IEC 60228

Insulation PVC type PVC/A acc. to IEC 60502

Core identification single core-black, multiple coreaccording to VDE 0293

Sheath PVC type ST1 acc. IEC 60502

Color black

Technical data

Conductor resistance at20∞—

According to IEC 60228class 1 or 2

Max. conductortemperature

+70∞—

Max. short circuittemperature

+160∞—, not more than 5sec

Rated voltage Uo/U 0.6/1 kV

Test voltage 3.5 kV

Bending radius-single core-multi core

15 cable diameter12 cable diameter

Flame test IEC 332 part 1

Note Other core configuration and special constructions manufactured upon request. Cables with same construction may produced according to IEC 60502

22

Application AYY is used in power plants industrial and switching installations, in secondary distribution networks and other.Thesecables are preferentially used in outdoor applications, for indoor instalations, in the open air, underground and in waterwhere mechanical damage is not anticipated.

L O W

V O L T A G E P O W E R C

A B L E

AYY-0AYY-J

Uo/U - 0.6/1 kVIEC 60502-1

Construction data AYY o/j 0.6/1 kV

Number of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Al weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

Construction data AYY o/j 0.6/1 kV

Number of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Al weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

4 x 16,0 re 20.3 180 4604 x 25,0 rm 24.9 270 6704 x 50,0 sm 28.9 520 11804 x 70,0 sm 33.2 760 13904 x 95,0 sm 37.6 1060 1860

4 x 120,0 sm 40.6 1340 22104 x 150,0 sm 45.4 1650 27104 x 185,0 sm 49.8 2100 33204 x 240,0 sm 55.9 2720 4110

Al conductors PVC insulation PVC sheath

E L K A B E L

Page 24: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 24/430

23

L O W

V O L T A G E P O W

E R C A B L E S

Application

S Z A M K A M Uo/U - 0.6/1 kVIEC 60502-1

Used for transferring and distribution of electrical power for switching installations and outdoor installation or for interiorinstallation in rooms, in canals, tunnels, shafts or pits, at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.

Cable construction

Construction According to IEC 60502-1Conductor Aluminum wires solid or stranded

class 1 or 2, according to IEC 60228Insulation PVC compoundCable core Insulated cores are twisted

Inner sheath Polymer tapesMetal screen Al tapesSheath PVC compoundColor black

Conductors typere circular, solid conductorrm circular, stranded conductorsm sector, stranded conductor

Technical data

Color coding

4 - core - blue, brown, black, grey

Conductor resistance at20∞— According to to IEC 60228

Max. conductortemperature 70∞—

Max. short circuittemperature +160∞—, not more than 5sec

Rated voltage 0,6/1 kV

Test voltage AC - 4 kV 50 HzDC - 12 kV

Bending radius, min. 10 D cable

Temperature of laying -5∞—

Temperature range -30∞— to +50∞—

Al conductors PVC insulation Al tapes screen PVC sheath

CONSTRUCTIONAL and ELECTRICAL DATA Number ofconductorsand nominalcross section

Thic-kness

of insula-tion

Beddinglayer

polyestertapes

Aluminiumtapes

Thicknessof sheath

Outer diameterapprox.

Current carryingcapacity in

air

Current carry-ing capacity in

ground

N x mm mm mm mm mm mm A A

4x16 re4x25rm

4x50sm4x95sm

4x150sm4x185sm

4x240 sm

1.01.2

1.41.6

1.82.0

2.2

0.40.4

0.40.4

0.60.6

0.6

0.40.4

0.40.4

0.60.6

0.6

1.81.8

2.02.3

2.62.7

3.0

21.024.5

30.039.0

47.052.0

58.0

6383

125190

252289

339

76102

144215

275313

364

E L K A B E L

Page 25: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 25/430

Cable construction

Construction According to VDE 0276 part 603

Conductor solid or multi-strand Cu wires class 1or 2 acc. VDE 0295 (IEC 60228)

Insulation PVC type DIV4 acc. VDE0276

Core identification according to VDE 0293

Inner sheath tapes and filling compound

Concentricconductor Cu wires and Cu tapes

Sheath PVC type DMV5 acc. VDE 0276

Color black

Technical data

Color coding 3 - core 4 - core

brownblackgrey

bluebrownblackgrey

24

Application

NYCY is used in power plants, industrial and switching installations, for street lighting, domestic power supply connec-tions, in secondary distribution networks and other.These cables are preferentially used for underground application aswell as for interior installation in room and cableducts and for outdoor and applications, for indoor installations, in theopen air, underground and in water where greater mechanical protection an protection against accidental contact isrequired if damaged.

L O W

V O L T A G E P O W E R C

A B L E

NYCY Uo/U - 0.6/1 kV VDE 0276 part 603

Single core - blackDouble core - blue and brown

Conductor resistance at

20∞—

According to VDE 0295

class 1 or 2 (IEC 60228)

Max. conductor

temperature+70∞—

Max. short circuit

temperature

+160∞—, not more than 5

sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 4 kV 50 Hz

Bending radius

-single core

-multi core

15 cable diameter

12 cable diameter

Flame testVDE 0472 part 804 class B

(IEC 332 part 1)

E L K A B E L

Page 26: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 26/430

25

L O W

V O L T A G E P O W

E R C A B L E S

Cu conductors PVC insulation Cu concentric conductor PVC sheath

Construction data NYCY 0.6/1 kV

Number of wires andnominal cross section Shape

Concentricconductor

cross section

Outer diameter ofcable

approx.

Cu weight

Cable weightapprox.

N ı mm

2

mm kg/km kg/km1 x 1,51 x 2,51 x 4,01 x 6,01 x 101 x 161 x 251 x 352 x 1,52 x 2,52 x 4,0,2 x 6,02 x 102 x 16

2 x 252 x 352 x 503 x 1,53 x 2,53 x 4,03 x 6,03 x 103 x 163 x 253 x 253 x 353 x 353 x 503 x 353 x 353 x 503 x 503 x 703 x 703 x 953 x 95

3 x 1203 x 1203 x 1503 x 1503 x 1853 x 2404 x 1,54 x 2,54 x 4,0

4 x 6,04 x 104 x 164 x 254 x 354 x 504 x 354 x 504 x 704 x 95

4 x 1204 x 1504 x 1854 x 240

rerererererermrmrererererere

rmrmrmrerererererermrmrmrmrmsmsm

smsmsmsmsmsmsmsmsmsmsmsmrerere

rererermrmrmsmsmsmsmsmsmsmsm

1,52,54,06,0101625351,52,54,06,01016

2535501,52,54,06,010161625163525351625503570509570

12070

15095

1201,52,54,0

6,0101616162516253550707095

120

7,98,59,49,9

11,312,812,916,413,013,715,917,119,121,0

25,127,831,513,514,316,617,720,022,127,826,629,129,432,727,126,629,630,633,634,138,239,438,341,644,745,849,054,514,316,317,8

19,021,523,829,032,036,429,833,138,442,643,150,755,362,3

274774

1081822974656544568

110164274435

7039801343

5690

147243365580855938

11271317158113391161159318192265258431513692403844434827554360517881

70136183

297457725

1090145619981495204429114041516262147826

10150

98122163203286410606807230273375458619841

127616422193252305425528724999

1440152418131987241516441627217422602932309740044336492551245890635273299399284382494

620860

11961764224630242060273037585054624675489374

12124

Note: Other core configuration and special constructions manufactured upon request.

E L K A B E L

Page 27: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 27/430

Cable construction

Construction According to VDE 0276 part 603

Conductor solid or multi-strand Al wires class 1or 2 acc. VDE 0295 (IEC 60228)

Insulation PVC type DIV4 acc. VDE0276

Core identification according to VDE 0293

Inner sheath tapes and filling compound

Concentricconductor Cu wires and Cu tapes

Sheath PVC type DMV5 acc. VDE 0276

Color black

Technical data

Color coding

Single core - blackDouble core - blue and brown

26

Application

NAYCY is used in power plants, industrial and switching installations, for street lighting, domestic power supply con-nections, in secondary distribution networks and other.These cables are preferentially used for underground applicationas well as for interior installation in room and cable ducts and for outdoor and applications, for indoor installations, inthe open air, underground and in water where greater mechanical protection an protection against accidental contact isrequired if damaged.

L O W

V O L T A G E P O W E R C

A B L E

N A Y C Y Uo/U - 0.6/1 kV VDE 0276 part 603

3 - core 4 - core

brownblackgrey

bluebrownblackgrey

Conductor resistance at20∞—

According to VDE 0295class 1 or 2 (IEC 60228)

Max. conductortemperature

+70∞—

Max. short circuittemperature

+160∞—, not more than 5sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 4 kV 50 Hz

Bending radius-single core-multi core

15 cable diameter12 cable diameter

Flame testVDE 0472 part 804 class B

(IEC 332 part 1)

E L K A B E L

Page 28: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 28/430

27

L O W

V O L T A G E P O WE R C A B L E S

Al coductors PVC isulation Cu concentric conductor PVC sheath

Construction data NAYCY 0.6/1 kV

Number of wiresand nominal cross

section Shape

Concentricconductor

cross section

Outer diameterof cableapprox.

Al weight Cu weight Cable weightapprox.

N ı mm2 mm2 mm kg/km kg/km kg/km

3 x 35,03 x 50,03 x 70,03 x 95,0

3 x 120,03 x 70,03 x 70,03 x 95,03 x 95,0

3 x 120,03 x 120,03 x 150,03 x 150,03 x 185,0

reresesesesmsmsmsmsmsm

smsmsm

35507095

1203570509570

12070

15095

27,931,533,136,940,033,134,137,738,740,240,944,245,448,6

291392567785993584584809809

10231023

125712571579

230335456665849236413296580432694

432804580

11431522167522472715148916481974225323812654279831643498

Note Other core configuration and special constructions manufactured upon request.

E L K A B E L

Page 29: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 29/430

Cable construction

Construction According to VDE 0276 part 627

Conductor solid or multi-strand Cu wires class1or 2 acc. VDE 0295 (lEC 60228)

Insulation PVC type DIV4 acc. VDE0276

CoreIdentification according to VDE 0293

Inner sheath tapes and filling compound

Concentric of plain round copper wires and one orconductor two transverse counter helix of copper

tapes

Sheath PVC type DMV5 acc. VDE 0276

Color black

Technical data

28

Application

NYCY is used in power plants, industrial and switching installations, for street lighting, domestic power supply connec-

tions, in secondary distribution networks and other.These cables are also used as control cables for transmission ofmeasured values control and regulation pulses.These cables are preferentially used for underground application aswell as for interior installation in room and cableducts and for outdoor and applications, for indoor installations, in theopen air, underground and in water where greater mechanical protection an protection against accidental contact isrequired if damaged.

L O W

V O L T A

G E P O W E R C A

B L E S

NYCY Uo/U 0.6/1 kV VDE 0276 part 627

E L K A B E L

Color coding

Black with number mark on cores or black with numbermark on cores and yellow/green in the outer cover

Conductor resistance at20∞C

According to VDE 0295class 1 or 2 (IEC60228)

Max. conductor

temperature

+70∞ C

Max. short circuittemperature

+160∞ C, not more than 5sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 4 kV 50 Hz ,

Bending radius-single core-multi core

15 cable diameter12 cable diameter

Flame testVDE 0472 part 804 class B

(lEC 332 part 1)

Page 30: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 30/430

29

L O W

V O L T A G E P O W

E R C A B L E S

Cu conductors PVC insulation Cu concentric conductor PVC sheath

Construction data NYCY 0.6/1 kV

Number of conductorsand nominal cross

sectionShape

Concentricconductor

cross section

Outer diameterapprox. Copper weight

Cable weightapprox.

N ı mm2 mm2 mm kg/km kg/km

7 x 1,58 x 1,5

10 x 1,512 x 1,514 x 1,516 x 1,519 x 1,520 x 1,521 x 1,524 x 1,527 x 1,530 x 1,537 x 1,5

7 x 2,58 x 2,5

10 x 2,512 x 2,514 x 2,516 x 2,519 x 2,520 x 2,521 x 2,524 x 2,527 x 2,530 x 2,537 x 2,57 x 4,08 x 4,0

10 x 4,012 x 4,014 x 4,016 x 4,019 x 4,0

rerererererererererererere

rerererererererererererererere

rerererere

2,52,52,52,52,54,04,06,06,06,06,06,06,0

2,54,04,04,06,06,06,01010101010104,06,0

6,06,06,01010

16,317,619,319,820,621,522,423,423,425,526,026,929,2

17,419,020,921,422,323,324,425,925,928,529,030,032,220,322,7

25,225,526,628,529,8

129143171199227286307337351393435477620

191224270315377422491560582651719787946298358

441497570705799

391453540578629699772828850

1000105211291355

482573687742830905

1016111411461355143315421801687833

10191089120213861550

Note

Œther core configuration and special constructions manufactured upon request.Cables with same construction may produced according to lEC 60502

E L K A B E L

Page 31: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 31/430

Cable construction

Construction According to IEC 60502-1

Conductor solid or multi-strand Cu wires class 1or 2 acc. IEC 60228

Insulation PVC acc. to IEC 60502

Core identification single core-black, multiple coreaccording to VDE 0293

Inner sheath tapes and filling compound

Armour two steel tapes or two galvanizedsteel tapes

Sheath PVC type ST1 acc. IEC 60502Color black

Technical data

Conductor resistance at20∞—

According to IEC 60228class 1 or 2

Max. conductortemperature +70∞—

Max. short circuittemperature

+160∞—, not more than 5sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 3.5 kV 50 Hz

Bending radius-single core-multi core

15 cable diameter12 cable diameter

Flame test IEC 332 part 1

30

Application

YBY is used in power plants, industrial and switching installations, for street lighting, domestic power supply connections,in secondary distribution networks and other.These cables are also used as control cables for transmission of measuredvalues control and regulation pulses.These cables are preferentially used for underground application as well as for interi-or installation in room and cableducts and for outdoor and applications, for indoor installations, in the open air, under-ground and in water where greater mechanical protection an protection against accidental contact is required if damaged.

L O W

V O L T A G E P O W E R C

A B L E

YBY-0 ; YBY -J Uo/U - 0.6/1 kVIEC 60502-1

Constructive data YBY-o/j 0.6/1 kV

Number ofconductors and nom. cross sec. Shape

Outerdiameter approx.

Cu weight approx.

Cable weight approx.

N ı mm2 mm kg/km kg/km

2 x 4,02 x 6,02 x 102 x 162 x 252 x 352 x 503 x 4,03 x 6,0

3 x 103 x 163 x 253 x 353 x 503 x 703 x 95

3 x 1203 x 1503 x 1853 x 2403 x 300

3 x 4,0 + 2,53 x 6,0 + 43 x 10 + 6

3 x 16 + 103 x 25 + 163 x 35 + 16

rerererermrmrmrere

rerermrmrmsmsmsmsmsmsmsm

re/rere/rere/re

re/rerm/rmrm/rm

16,517,519,121,025,127,330,717,218,3

20,022,126,629,132,833,038,040,044,247,953,358,717,819,221,0

23,227,830,1

75112188298485673908112168

282447728

101013631968273234404245531169818661135205338

5418811163

466552688878

127715772016524621

8041048154119422498290940854860591072019184

11182558681883

117017212108

E L K A B E L

Page 32: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 32/430

31

L O W

V O L T A G E P O W

E R C A B L E

Cu conductors PVC insulation Armour St. tapes PVC sheath

Constructive data YBY-o/j 0.6/1 kV

Number ofconductors and nom. cross sec. Shape

Outerdiameterapprox.

Cu weightapprox.

Cable weightapprox.

N ı mm2 mm kg/km kg/km

3 x 50 + 253 x 70 + 353 x 95 + 50

3 x 120 + 703x150 + 70

3 x 185 + 953 x 240 + 1203 x 300 + 150

4 x 4,04 x 6,04 x 104 x 164 x 254 x 35

4 x 504 x 704 x 95

4 x 1204 x 1504 x 1854 x 2404 x 3005 x 4,05 x 6,05 x 105 x 165 x 255 x 355 x 50

5 x 707 x 1,58 x 1,5

10 x 1,512 x 1,514 x 1,516 x 1,519 x 1,520 x 1,521 x 1,524 x 1,527 x 1,530 x 1,537 x 1,57 x 2,58 x 2,5

10 x 2,512 x 2,514 x 2,516 x 2,519 x 2,520 x 2,521 x 2,524 x 2,527 x 2,530 x 2,537 x 2,57 x 4,08 x 4,0

10 x 4,07 x 6,0

8 x 6,010 x 6,0

sm/rmsm/rmsm/rmsm/rmsm/rmsm/rmsm/rmsm/rm

rerererermrm

smsmsmsmsmsmsmsmrerererermrmrm

rmrererererererererererererere

rererererererererererererererere

rere

33,038,242,445,650,254,560,966,718,319,521,423,829,031,9

33,038,242,445,650,254,560,966,719,621,023,225,731,734,940,1

45,316,918,219,920,421,222,123,024,024,026,126,627,529,418,019,621,522,022,923,925,026,126,128,629,230,232,320,922,925,422,4

19,527,4

1605230431874096490162228128

10076149223376595970

1346

1817262436434587566070829308

11548187279470744

121316832271

3280100114142171199227270284299341384426526163186232279325372441464488557627697859261299373391

447559

258836594753580868548470

1069913112

607728960

126518922399

281539925226631376819366

1201214645

696843

11201495226628863990

5243492570676719791850934

100310151181123913261526596694830892975

10671183127212911518160217231998824970

12121043

12291496

Note: Other core configuration and special constructions manufactured upon request. Cables with same construction may produced according to IEC 60502

E L K A B E L

Page 33: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 33/430

Cable construction

Construction According to IEC 60502-1

Conductor solid or multi-strand Al wires class 1or 2 acc. IEC 60228

Insulation PVC acc. to IEC 60502

Core identification single core-black, multiple coreaccording to VDE 0293

Inner sheath tapes and filling compound

Armour two steel tapes or two galvanizedsteel tapes

Sheath PVC type ST1 acc. IEC 60502

Color black

Technical data

32

Application

AYBY is used in power plants, industrial and switching installations, for street lighting, domestic power supply connec-

tions, in secondary distribution networks and other.These cables are also used as control cables for transmission ofmeasured values control and regulation pulses.These cables are preferentially used for underground application aswell as for interior installation in room and cableducts and for outdoor and applications, for indoor installations, in theopen air, underground and in water where greater mechanical protection an protection against accidental contact isrequired if damaged.

L O W

V O L T A G E P O W E R C

A B L E

AYBY-0AYBY-J

Uo/U - 0.6/1 kVIEC 60502-1

Conductor resistance at20∞—

According to IEC 60228class 1 or 2

Max. conductortemperature

+70∞—

Max. short circuittemperature

+160∞—, not more than 5sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 3.5 kV 50 Hz

Bending radius-single core-multi core

15 cable diameter12 cable diameter

Flame test IEC 332 part 1

E L K A B E L

Page 34: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 34/430

33

L O W

V O L T A G E P O W

E R C A B L E

Al conductors PVC insulation Armour St. tapes PVC sheath

Note: Other core configuration and special constructions manufactured upon request.Cables with same construction may produced according to IEC 60502

Construction data AYBY-o/j 0.6/1 kV

Number of conductors andnominal cross section Shape Outer diameter

approx. Al weight

approx.Cable weight

approx.

N ı mm2 mm kg/km kg/km

2 x 6,02 x 102 x 162 x 252 x 352 x 503 x 6,03 x 103 x 163 x 253 x 353 x 503 x 70

3 x 953 x 1203 x 1503 x 1853 x 2403 x 300

3 x 6,0+43 x 10+6

3 x 16+103 x 25+163 x 35+163 x 50+253 x 70+353 x 95+50

3 x 120+70

3 x 150+703 x 185+95

3 x 240+1203 x 300+150

4 x 6,04 x 104 x 164 x 254 x 354 x 504 x 704 x 95

4 x 1204 x 1504 x 185

4 x 2404 x 3005 x 6,05 x 105 x 165 x 255 x 355 x 50

rererermrmrmrererermrmrmsm

smsmsmsmsmsm

re/rere/rere/re

rm/rmrm/rmsm/rmsm/rmsm/rmsm/rm

sm/rmsm/rmsm/rmsm/rm

rererermrmsmsmsmsmsmsm

smsmrererermrmrm

17,519,121,025,127,330,718,320,022,126,629,132,833,0

38,040,044,247,953,358,719,221,023,227,830,133,038,242,445,6

50,254,560,966,719,621,523,829,031,933,038,242,445,650,254,5

60,966,721,023,225,731,734,940,1

385688

1441992695683

132216298404584

80910231257157920712589

68102160261343476684944

1218

1452184824123008

75111176288398539779

1079136416762106

2762345294

139220360497673

473563680955

11291412516616751

1058127015931599

226425723081366645355433552660811

113513341536212526293083

3628432953646430588710869

12471503159522462798326239094654

58146980668807

1000145917652479

E L K A B E L

Page 35: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 35/430

Cable construction

Construction According to BS 6346

Conductor Cu wires,class 1 or 2 according toBS 6360 (IEC 60228)

Insulation PVC type TI-1 acc. to BS 7655

Core according to BS 7655identification

Inner sheath filling compound

Armour galvanized steel wires

Sheath PVC compound type TM-1 acc. toBS 7655

Color black

Technical data

34

Application

These cables are used in power plants, industrial and switching installations, for street lighting, domestic power supplyconnections, in secondary distribution networks and other.These cables are preferentially used for underground appli-

cation as well as for interior installation in room and cableducts and for outdoor and applications, for indoor installa-tions, in the open air, underground and in water where greater mechanical protection an protection against accidentalcontact is required if damaged.

L O W

V O L T A G E P O W E R C

A B L E

PVC/SWA/PVC Uo/U - 0.6/1 kVBS 6346

Conductor resistance at20∞—

According to BS 6360( IEC 60228) class 1 or 2

Operating temperaturemax.

70∞C continuous operation

Short circuit temperature 250∞C /5 s max./

Nominal voltage Uo/U: 0.6/1 kV

Test voltage 3.5 kV

Temperature rangelaying and installing

exploitation and storage-5∞C to +60∞C-25∞C to +70∞C

Bending radius, min.approx.

Flame test

6 x D cableIEC 332-1

E L K A B E L

Construction data PVC/SWA/PVC 0.6/1 kV

Number of wires and

nominalcross

section

Shape

Outerdiameterof cableapprox.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

Construction data PVC/SWA/PVC 0.6/1 kV

Number of wires and

nominalcross

section

Shape

Outerdiameterof cableapprox.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

2 x 1,5 re 11,5 20 2732 x 1,5 rm 12,2 30 2902 x 2,5 re 12,9 46 3362 x 2,5 rm 13,4 48 3502 x 4,0 rm 14,9 77 4512 x 6,0 rm 16,2 115 5432 x 10 rm 19,9 194 8722 x 16 rm 21,9 307 10872 x 25 rm 26,3 485 16722 x 35 rm 28,6 673 2001

3 x 1,5 re 12,2 43 3113 x 1,5 rm 12,6 45 3213 x 2,5 re 13,4 70 383

3 x 2,5 rm 13,9 72 3973 x 4,0 rm 15,5 115 515

3 x 6,0 rm 17,7 173 7323 x 10 rm 20,8 201 10063 x 16 rm 23,0 460 12883 x 25 rm 27,6 728 19703 x 35 rm 30,1 1010 2410

4 x 1,5 re 12,9 57 3444 x 1,5 rm 13,4 60 3574 x 2,5 re 14,3 93 4344 x 2,5 rm 14,9 96 4524 x 4,0 rm 17,5 154 6064 x 6,0 rm 18,9 230 8464 x 10 rm 22,4 388 11844 x 16 rm 26,2 614 1721

4 x 25 rm 29,9 970 23464 x 35 rm 32,6 1346 2901

Page 36: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 36/430

L O W

V O L T A G E P

O WE R C A B L E S

W

I T H X L P E I N S U L A T I O N

E L K A B E L

Page 37: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 37/430

Cable construction

Construction According to IEC 60502-1Conductor Cu solid or stranded wires class 1

or 2 according to IEC 60228Insulation XLPE compoundIdentification of color code acc. to VDE 0276-603coresFilling filling compoundSheath PVC type ST2Color black

Technical data

36

Application

The power cables with insulation of cross-linked polyethylene (XLPE) are designed for distribution and supply of con-sumers with nominal voltage 0.6/1 kV and frequency 50 Hz in industrial installations and urban networks.

They are suitable for fixed indoor assembly in cable ducts and conduits, over shelves and grilles, directly undergroundin ditch and outdoor under shelters providing the conditions determined for the type of cable.

L O W

V O L T A G E P O W E R C

A B L E

2XY -0 ; 2XY -J Uo/U - 0.6/1 kVIEC 60502-1

Short circuit temperature 250∞C ( 5 sec.)

Nominal voltage 0.6/1 kV

Highest system voltage 1.2 kV

Test voltage, AC 50 Hz 4.0 kV

Bending radiussingle coremulticore

15 x Dcable15 x Dcable

Temperature of laying-5∞C to 60∞C

-30∞C to 70∞C /for PEsheath/

Temperature ofexploitation -30 to 70∞C

Test According to IEC 60502-1

Technical data

Conductor resistanceOperating temperature

According to IEC 6022890∞C

Overload temperature 130∞C/1`00h per year

Construction data 2XY-o/j 0.6/1 kVNumber of con-

ductors and nomi-nal cross section

Thicknessof insulation

Thicknessoff sheath Cu weight Cable weight

approx.

N ı mm2 mm mm min/mm max/mm kg/km kg/km

Outer diameterapprox.

1x501x701x95

1x1201x1501x1851x2401x3001x4001x500

4x164x254x354x504x704x95

4x1204x1504x185

1,01,11,1

1,21,41,61,71,82,02,2

0,70,90,91,01,11,1

1,21,41,6

1,81,81,8

1,81,81,81,81,81,92,0

1,81,81,81,92,12,1

2,32,42,6

14,616,518,5

20,021,924,126,629,432,936,7

20,524,325,328,232,836,6

39,844,048,4

171920

22242730323740

243132354044

485858

454656911

1147141517702827288736924725

614970

1346181726243643

458756607082

564779

1032

1275156119252488305838874937

94213981644216029994045

502061817640

Cu conductors XLPE insulation PVC sheath

E L K A B E L

Page 38: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 38/430

37

Cable construction

Construction According to IEC 60502-1

Conductor Al solid or stranded wires class 1or 2 according to IEC 60228

Insulation XLPE compound

Identification of color code acc. to VDE 0276-603cores

Filling filling compound

Sheath PVC type ST2

Color black

Technical data

L O W

V O L T A G E P O W

E R C A B L E

Al conductors XLPE insulation PVC sheath

Application

The power cables with insulation of cross-linked polyethylene (XLPE) are designed for distribution and supply of con-sumers with nominal voltage 0.6/1 kV and frequency 50 Hz in industrial installations and urban networks.They are suitable for fixed indoor assembly in cable ducts and conduits, over shelves and grilles, directly underground

in ditch and outdoor under shelters providing the conditions determined for the type of cable.

-0; ¿2XY-J Uo/U - 0.6/1 kVIEC 60502-1

Conductor resistanceOperating temperature

According to IEC 6022890∞C

Overload temperature 130∞C/100h per year

Short circuit temperature 250∞C ( 5 sec.)

Nominal voltage 0.6/1 kVHighest system voltage 1.2 kVTest voltage, AC 50 Hz 4.0 kV

Bending radiussingle coremulticore

15 x Dcable15 x Dcable

Temperature of laying -5∞C to 60∞C-30∞C to 70∞C /for PEsheath/

Temperature of exploita-tion -30 to 70∞C

Test According to IEC 60502-1

Construction data A2XY-o/j 0.6/1 kVNumber of con-

ductors and nomi-nal cross section

Thickness of insu-lation

Thickness ofsheath Al weight Cable weight

approx.

N ı mm2 mm mm min/mm max/mm kg/km kg/km

Outer diameterapprox.

1x50rm1x70rm

1x95rm1x120rm1x150rm1x185rm1x240rm1x300rm1x400rm1x500rm

4x16re4x25re4x35re4x50sm4x70sm4x95sm

4x120sm4x150sm4x185sm4x240sm

1,01,1

1,11,21,41,61,71,82,02,2

0,70,90,91,01,11,11,21,41,61,7

1,81,8

1,81,81,81,81,81,81,92,0

1,81,81,81,92,12,12,32,42,62,7

14,616,5

18,520,021,924,126,629,432,936,7

20,524,325,328,232,836,639,844,048,462,8

1719

2022242730323740

24313235404448535864

135195

270341419526690863

11091461

176288398539779

10791364167621052762

245318

391469565681846

103413041673

546792977

1259144518112233269634544129

E L K A B E L

Page 39: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 39/430

Cable construction

Construction According to IEC 60502-1

Conductor solid or multi-strand Al or Cuwires class 1 or 2 acc. IEC 60228

Insulation XLPE COMPOUND

Inner sheath PVC compound

Armour Al wires twisted concentrically

Sheath PVC compound type ST2

38

Application

The power and control cables with cross-linked polyethylene (XLPE) armored with galvanized iron wires are used inelectrical installations with nominal voltage Uo/U 0.6/1 kV. These cables are used in industrial installations and urbannetworks.These cables are for fixed assembly in lines with unlimited difference levels, for laying in industrial installations, in cableducts, tunnels and conduits, over shelves and grilles outdoor under shelters.

L O W

V O L T A

G E P O W E R C A

B L E S

2 X Y R a YA 2 X Y R a Y

Uo/U - 0.6/1 kVIEC 60502-1

Technical data

Conductor resistance

at 20∞—

According class 1 or 2

IEC 60228

Max. conductor

temperature90∞— continuous operation

Overload temperature 130∞C /100h/per year χı./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U 0.6/1 kV

Highest system voltage 1.2 kV

Test voltage AC - 5 min.

between cores - 3.5 ÍV

between core and screen -

3.5 ÍV

Bending radius, min. - 15x D cable

Temperature of laying no less than 0∞—

Temperature of

exploitation- 30 to 50∞—

E L K A B E L

Page 40: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 40/430

39

L O W

V O L T A G E P O W

E R C A B L E S

Cu/ Al conductors XLPE insulation PVC sheath Armour Al. Wires PVC sheath

Construction data 2XYRaY , A2XYRaY 0.6/1 kV

Number ofconductorsand nominal

cross section

Thickness ofinsulation

Thickness ofsheath

Cable diame-ter

approx. Mass ofCu

approx

Cable weightapprox.

Mass of Al

approx

Cable weightapprox.

N ı mm2 mm mm mm kg/km kg/km kg/km kg/km

1x25 rm1x35 rm1x50 rm1x70 rm1x95 rm

1x120 rm1x150 rm1x185 rm1x240 rm1x300 rm

0.90.91.01.11.11.21.41,61,71,8

1.81.81.81.81.81.81.81.92.02.1

16.317.418.720.522.924.526.328.431.234.6

229325458648885

11201378177023272887

532657833

1073141716992028264333354118

6895

127190260325405510665830

370425498611785896

1046137116562040

2XYRaY A2XYRaY

E L K A B E L

Page 41: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 41/430

Cable construction

Construction According to IEC 60502-1

Conductor solid or multi-strand Al or Cuwires class 1 or 2 acc. IEC 60228

Insulation XLPE compound

Inner sheath PVC compound

Armour St wires twisted concentrically

Sheath PVC compound type ST2

40

Application

The power and control cables with cross-linked polyethylene (XLPE) armored with galvanized iron wires are used inelectrical installations with nominal voltage Uo/U 0.6/1 kV. These cables are used in industrial installations and urbannetworks. These cables are for fixed assembly in lines with unlimited difference levels, for laying in industrial installa-tions, in cable ducts, tunnels and conduits, over shelves and grilles outdoor under shelters.

L O W

V O L T A

G E P O W E R C A

B L E S

2XYRY-0 /JA2XYRY-0 /J

Uo/U - 0.6/1 kVIEC 60502-1

Technical data

Conductor resistanceat 20∞—

According class 1 or 2IEC 60228

Max. conductor tempera-ture

90∞— continuous operation

Overload temperature 130∞C /100h/per year χı./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U 0.6/1 kV

Highest system voltage

Test voltage AC - 5 min.

1.2 kVbetween cores - 3.5 ÍV

between core and screen -3.5 ÍV

Bending radius, min. - 15x D cable

Temperature of laying no less than 0∞—

Temperature of

exploitation - 30 to 50∞—

E L K A B E L

Color coding

Double core - blue and brown or yellow - green and black

3-core 4-core 5-core Multiple core

brownblackgreyor

yellow/greenblue

brown

bluebrownblackgreyor

yellow/greenbrownblack

grey

bluebrownblackgreyblackor

yellow/greenbluebrownblackgrey

black withnumbered mark or cores

orblack with number mark

on cores andyellow/green core in the

outer cover

Page 42: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 42/430

41

L O W

V O L T A G E P O W

E R C A B L E S

Cu/ Al conductors XLPE insulation PVC sheath Armour St. Wires PVC sheath

Construction data 2XYRY-O/J , A2XYRY-O/J 0.6/1 kV

Number ofconductorsand nominal

cross section

Thickness ofinsulation

Thickness ofsheath

Cablediameterapprox. Mass of

Cuapprox.

Cable weightapprox.

Mass of Al

approx.

Cable weightapprox.

N.ı.mm2 mm mm mm kg/km kg/km kg/km kg/km

2 ı 2.5 rm2 ı 4 rm

2 ı 10 rm2 ı 16 rm2 ı 25 rm2 ı 50 rm2 x 95 rm3 ı 1.5 rm3 ı 2.5 rm

3 ı 4 rm3 ı 6 rm

3 ı 10 rm3 ı 16 rm3 ı 25 rm3 ı 35 rm3 ı 50 rm3 ı 70 sm4 ı 2.5 rm4 ı 4 rm4 ı 6 rm

4 ı 10 rm4 ı 16 rm4 ı 25 rm4 ı 35 rm

4x50 sm4x70 sm4x95 sm

4x120 sm4x150 sm4x185 sm4x240 sm7 x 1.5 rm7 x 2.5 rm

12 x 1.5 rm19 x 2.5 rm

0.70.70.70.70.91.01.10.70.7

0.70.70.70.70.90.91.01.10.70.70.70.70.70.90.9

1,41,41,61,61,82

2.20.70.70.70.7

1.81.81.81.81.81.92.11.81.8

1.81.81.81.81.81.81.92.11.81.81.81.81.81.81.9

2.12,12,12,22,42,52,61.81.81.81.8

14.115.218.920.324.929.238.216.516.5

17.517.819.821.325.427.830.934.616.617.519.121.223.6.27.530.2

34.438.943.047.551.856.062.317.018.220.425.6

4675

188298485908

18224370

112168282447728

101013631968

93149223376595970

1346

1817262436434587566070829308

96160165435

421500863

1050158423764058596619

713774987

12341878232029013750933

106012481576227830593701

35354701601776269144

1097613861

960111912942277

14235690

1402695391321

365185

135210290385585284668

112180270390

520760

10601340165021002720

304951

133

388448729840

123617302762566570

636656788919

1355159319142353867956

10911309185923522736

2225281834084346509459457207894

100711791972

2XYRY-O/J A2XYRY-O/J

E L K A B E L

Page 43: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 43/430

Cable construction

Construction According to VDE 0276-603/5G

Conductor Cu solid or stranded wires class 1or 2 according to HD 383, VDE0295

Insulation XLPE type DIX3acc. to VDE 0276-603/5G

Identification of Color code acc. to VDE 0276-603cores

Filling filling compound

Sheath PVC type DMV6,acc. to VDE 0276-603/sec.1

Color black

Technical data

Conductor resistanceOperating temperature

According to VDE 029590∞C

Overload temperature 130∞C/100h per year

Short circuit temperature 250∞C ( 5 sec.)

Nominal voltage 0.6/1 kV

Highest system voltage 1.2 kV

Test voltage, AC 50 Hz 4.0 kV

Bending radiussingle coremulticore

15 x Dcable15 x Dcable

Temperature of laying-5∞C to 70∞C

-30∞C to 70∞C /for PEsheath/

Temperature of exploita-tion

-30 to 70∞C

Test

According to DIN VDE 0276-

603

42

Application

The power cables with insulation of cross-linked polyethylene (XLPE) are designed for distribution and supply of con-

sumers with nominal voltage 0.6/1 kV and frequency 50 Hz in industrial installations and urban networks.They are suitable for fixed indoor assembly in cable ducts and conduits, over shelves and grilles, directly undergroundin ditch and outdoor under shelters providing the conditions determined for the type of cable.

L O W

V O L T A G E P O W E R C

A B L E

N2XY-0 /J Uo/U - 0.6/1 kV VDE 0276-603

Color coding

Single core - black or yellow/greenDouble core - blue and brown or yellow-green and black

3-core 4-core 5-core Multiple core

brownblackgreyor

yellow/green,blue,

brown

bluebrownblackgreyor

yellow/greenblackgrey

bluebrownblackgreyblackor

yellow/greenbluebrownblackgrey

black withnumber mark on cores

orblack with number mark

on cores andyellow/green core in the

outer cover

E L K A B E L

Page 44: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 44/430

43

L O W

V O L T A G E P O W

E R C A B L E

Construction data N2XY-o/j 0.6/1 kV

Number of conductorsand nominal

cross section

Thicknessof insulation

Thicknessof sheath

Outer diameterapprox. Cu weight Cable weight

approx.

N x mm mm mm mm kg/km kg/km

1ı16rm1x25rm1x35rm1x50rm1x70rm1x95rm

1x120rm1x150rm1x185rm1x240rm1x300rm

1x400rm1x500rm2x16rm2x25rm2x35rm2x50rm3x16rm3x25rm3x35rm3x50sm3x70sm3x95sm

3x120sm3x150sm3x185sm

3x240sm3x4+2.5re3x6+4re

3x10+6re3x16+10re3x25+16rm3x35+16rm

3x50+25sm/rm3x70+35sm/rm3x95+50sm/rm

3x120+70sm/rm3x150+70sm/rm3x185+95sm/rm

3x240+120sm/rm4x16rm

4x25rm4x35rm4x50sm4x70sm4x95sm

4x120sm4x150sm4x185sm

0.70.90.91,01,11,11,21,41,61,71,8

2,02,20,70.90.91.00.70.90.91.01.11.11.21.41.6

1.70.7/0.70.7/0.70.7/0.70.7/0.70.9/0.70.9/0.71.0/0.91.1/0.91.1/1.01.2/1.11.4/1.11.6/1.11.7/1.2

0,7

0,90,91.01,11,11,21,41,6

1.81.81.81,81,81,81,81,81,81,81,8

1,92,01,81.82.02.01.82.02.02.02.02.02.02.22.2

2.61.81.81.81.82.02.02.02.02.22.22.22.63.01,8

2.02.02.02.02,02,22,22,6

11.012.513.515.517.019.021

23.0273032

3740

19.523

25.529.020.524.527.024.528.031.034

37.042.0

47.513.515.017.020.027.029.528.533.036.539.044.048.557.022

2729.528.533.033.0394449

144228317454656911

11471415177023272887

36924725294466646924441699969

138718972631332440845123

6733135205338541846

11161620222030933956471660007841588

9321292185025302530443354466831

230340445605800

106512751610192524833058

38874937645946

12351680805

12201575176523503145391548206045

7885328445611868

140517652075265036154690563071509305985

15001955232031003100520064108050

Cu conductors XLPE insulation PVC sheath

E L K A B E L

Page 45: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 45/430

Cable construction

Construction According to VDE 0276-603/5G

Conductor Al solid or stranded wires class 1 or 2according to HD 383,VDE 0295

Insulation XLPE type DIX3acc. to VDE 0276-603/5G

Identification of color code acc. to VDE 0276-603cores

Filling filling compound

Sheath PVC type DMV6,acc. toVDE 0276-603/sec.1

Color black

Technical data

44

Application

The power cables with insulation of cross-linked polyethylene (XLPE) are designed for distribution and supply of con-sumers with nominal voltage 0.6/1 kV and frequency 50 Hz in industrial installations and urban networks.They are suitable for fixed indoor assembly in cable ducts and conduits, over shelves and grilles, directly undergroundin ditch and outdoor under shelters providing the conditions determined for the type of cable.

L O W

V O L T A G E P O W E R C

A B L E

N¿2XY-0N¿2XY-J

Uo/U - 0.6/1 kV VDE 0276-603

Color coding

Single core - black or yellow/greenDouble core - blue and brown or yellow-green and black

3-core 4-core 5-core Multiple core

brownblackgreyor

yellow/green,blue,

brown

bluebrownblackgreyor

yellow/greenbrownblackgrey

bluebrownblackgreyblackor

yellow/greenbluebrownblack

grey

black withnumber mark on cores

orblack with number mark

on cores andyellow/green core in the

outer cover

Conductor resistanceOperating temperature

According to VDE 029590∞C

Overload temperature 130∞C/100h per year

Short circuit temperature 250∞C ( 5 sec.)

Nominal voltage 0.6/1 kV

Highest system voltage 1.2 kV

Test voltage, AC 50 Hz 4.0 kV

Bending radiussingle coremulticore

15 x Dcable15 x Dcable

Temperature of laying-5∞C to 70∞C

-30∞C to 70∞C /for PEsheath/

Temperature of exploita-tion

-30 to 70∞C

Test According to DIN VDE 0276-603

E L K A B E L

Page 46: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 46/430

45

L O W

V O L T A G E P O W

E R C A B L E

Al conductors XLPE insulation PVC sheath

Construction data NA2XY-o/j 0.6/1 kV

Number of con-ductors and nomi-nal cross section

Thickness of insu-lation

Thickness ofsheath Al weight

Cable weightapprox.

N ı mm2 mm mm min/mm max/mm kg/km kg/km

Outer diameterapprox.

1x501x701x95

1x1201x1501x1851x2401x3001x400

1x500

4x164x254x354x504x704x95

4x1204x1504x1854x240

4x354x50

4x704x95

4x1204x1504x1854x240

1,01,11,11,21,41,61,71,82,02,2

0,70,90,91,01,11,11,21,41,61,7

0,91,0

1,11,11,21,41,61,7

1,81,81,81,81,81,81,81,81,9

2,0

1,81,81,81,92,12,12,32,42,62,7

1,81,9

2,02,12,22,42,52,7

14,616,518,520,021,924,126,629,432,936,7

20,524,325,328,232,836,639,844,048,462,8

26,530,0

33,637,440,243,848,854,0

171920222427303237

40

24313235404448535864

3033

384145495459

135195270341419526690863

1109

1461

176288398539779

10791364167621052762

388522

75610461324162620422679

245318391469565681846

10341304

1673

546792977

1259144518112233269634544129

9771259

144618122233269632854233

E L K A B E L

Page 47: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 47/430

Cable construction

Construction According to NF C 32-321Conductor Cu wires according to NF C 32-321

(IEC 60228):-rm class 1, 1.5 to 16mm2

-rm class 2, 1.5 to 500mm2

-sm class 2, 50 to240mm2

Insulation XLPE compound

Inner sheath tape or extrusion

Sheath PVC compound

Color black

Technical data

46

Application

These cables are used for distribution and supply of consumers with electrical power with nominal voltage 0.6/1kV and

frequency 50 Hz in industrial installations and urban networks.They are suitable for fixed indoor assembly in cable ducts, tunnels and conduits, over shelves and grilles, directlyunderground in ditch and outdoor under shelters providing the conditions determined for the type of cable.

L O W

V O L T A

G E P O W E R C A

B L E S

E L K A B E L

U 1 0 0 0 R 2 V Uo/U - 0.6/1 kVNF C 32-321

Conductor resistanceat 20∞—:

According to NF C 32-321

Operating temperature 90∞C continuous operation

Overload temperature 130∞C /100h/per year χı./

Short circuit temperature 250∞C /5 s max./

Nominal voltage Uo/U: 0.6/1 kV

Highest system voltage 1.2 kV

Temperature rangelaying and installing

exploitation and storage-5∞C to +60∞C-25∞C to +70∞C

Bending radius, min.approx.

10 x D cable

Color coding

Single core - black or yellow/greenDouble core - blue and brown or yellow-green and black

3-core 4-core 5-core Multiple core

brownblackgreyor

yellow/green,blue,

brown

bluebrownblackgreyor

yellow/greenbrownblackgrey

bluebrownblackgreyblackor

yellow/greenbluebrownblackgrey

black withnumber mark on cores

orblack with number mark

on cores andyellow/green core in the

outer cover

Page 48: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 48/430

47

L O W

V O L T A G E P O W

E R C A B L E S

E L K A B E L

Construction data U 1000 R2V 0.6/1 kV

Numberofconductorsand nominal

crosssection

Shape

Outercable

diameterapprox.

Cu weightCable

weightapprox.

N ı mm2 mm kg/km kg/km

Construction data U 1000 R2V 0.6/1 kV

Numberofconductorsand nominal

crosssection

Shape

Outercable

diameterapprox.

Cu weightCable

weightapprox.

N ı mm2 mm kg/km kg/km

1ı10 rm 9.2 93 1471ı16 rm 10.5 148 2091ı25 rm 12.5 229 3001ı35 rm 13.5 325 3991ı50 rm 15.0 458 5201ı70 rm 17.0 648 738

1ı95 rm 19.0 889 9901ı120 rm 21.0 1120 12351ı150 rm 23.0 1378 14801ı185 rm 25.5 1703 18351ı240 rm 28.5 2208 2370

2ı1.5 re 9.7 28 140

2ı2.5 re 10.5 46 1732ı4 re 11.5 75 2232ı6 rm 12.6 110 295

2ı10 rm 14.3 182 4102ı16 rm 16.0 303 5862ı25 rm 20.3 470 855

3ı1.5 re 10.1 42 1603ı2.5 re 11.0 69 2023ı4 re 12.1 110 2603ı6 rm 13.2 165 352

3ı10 rm 14.9 275 4983ı16 rm 17.0 450 720

3ı25 rm 21.9 700 10653ı35 rm 23.1 980 1393

3ı50 rm 27.0 1390 18303ı70 rm 31.3 1950 25703ı95 sm 35.8 2650 3460

3ı120 sm 39.6 3350 43043ı150 sm 44.0 4185 52803ı185 sm 49.0 5160 66123ı240 sm 55.6 6720 8588

3G1.5 re 10.1 42 1603G2.5 re 11.0 69 2023G4 re 12.1 110 260

3G6 rm 13.2 165 3523G10 rm 14.9 275 4973G16 rm 17.0 450 7203G25 rm 21.9 700 1065

3x50+35 sm/rm 29.3 1715 21503x70+50 sm/rm 34.2 2408 29823x95+50 sm/rm 38.2 3120 3830

3x120+70 sm/rm 42.8 4010 49173x150+70 sm/rm 46.9 4850 58483x185+70 sm/rm 51.8 5808 70683x240+95 sm/rm 58.5 7605 9241

Construction data U 1000 R2V 0.6/1 kVNumber

ofconductorsand nominal

crosssection

Shape

Outercable

diameterapprox.

Cu weightCable

weightapprox.

N ı mm2 mm kg/km kg/km

Construction data U 1000 R2V 0.6/1 kVNumber

ofconductorsand nominal

crosssection

Shape

Outercable

diameterapprox.

Cu weightCable

weightapprox.

N ı mm2 mm kg/km kg/km4x1.5 re 10.8 55 1824ı2.5 re 11.6 92 2364ı4 re 13.2 146 3124ı6 rm 14.3 218 418

4ı10 rm 16.5 363 6054ı16 rm 18.7 582 8684ı25 rm 22.6 925 1310

4G1.5 re 10.8 55 1824G2.5 re 11.6 92 2364G4 re 13.2 146 3124G6 rm 14.3 218 418

4G10 rm 16.5 363 6054G16 rm 18.7 582 8684G25 rm 22.6 925 13104G35 rm 25.3 1303 1730

4G50 rm 29.7 1857 22904G70 rm 34.7 2601 32404G95 ÒÏ 39.6 3540 4310

4G120 sm 44.0 4460 54474G150 sm 49.0 5575 66904G185 sm 55.0 6880 8400

4G240 sm 62.1 8928 10887

5G1.5 re 11.6 69 117

5G2.5 re 12.7 114 2745G4 re 14.3 182 3605G6 rm 15.4 275 497

5G10 rm 18.2 455 7255G16 rm 20.4 745 10605G25 rm 25.3 1165 1585

7G1.5 re 12.5 96 230

8G1.5 re 13.7 110 26010G1.5 re 15.4 140 31612G1.5 re 16.0 165 35714G1.5 re 16.5 195 40319G1.5 re 18.7 260 51124G1.5 re 21.5 330 63030G1.5 re 22.5 410 74837G1.5 re 24.8 506 890

7G2.5 re 13.7 160 3128G2.5 re 14.9 182 350

10G2.5 re 17.0 228 42812G2.5 re 17.6 275 48714G2.5 re 18.7 320 54519G2.5 re 20.9 435 701

24G2.5 re 24.2 546 86030G2.5 re 25.3 685 104537G2.5 re 27.5 845 1247

Cu conductors XLPE insulation PVC sheath

Page 49: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 49/430

Cable construction

Construction According to NF C 32-321

Conductor Aluminum wires acc. NF C 32-321- single core circular class 2,

2.5 to 35mm2- stranded class 2 round and- sector, 35 to240mm2

Insulation XLPE compound

Filling - up to 6 cores - PVC filling- 7 cores and more - polyester tape

Sheath PVC compound

Color black

Technical data

48

Application

These cables are used for distribution and supply of consumers with electrical power with nominal voltage 0.6/1kV andfrequency 50 Hz in industrial installations and urban networks.They are suitable for fixed indoor assembly in cable ducts, tunnels and conduits, over shelves and grilles, directlyunderground in ditch and outdoor under shelters providing the conditions determined for the type of cable.

L O W

V O L T A

G E P O W E R C A

B L E S

E L K A B E L

U 1 0 0 0 A R 2 V Uo/U - 0.6/1 kVNF C 32-321

Conductor resistance

at 20∞—: According to NF C 32-321

Operating temperature 90∞C continuous operation

Overload temperature 130∞C /100h/per year χı./

Short circuit temperature 250∞C /5 s max./

Nominal voltage Uo/U: 0.6/1 kV

Highest system voltage 1.2 kV

Temperature range

laying and installing

exploitation and storage

-5∞C to +60∞C

-25∞C to +70∞C

Bending radius, min.

approx.10 x D cable

Color coding

Single core - black or yellow/greenDouble core - blue and brown or yellow-green and black

3-core 4-core 5-core Multiple core

brownblackgreyor

yellow/greenblue

brown

bluebrownblackgreyor

yellow/greenbrownblackgrey

bluebrownblackgreyblackor

yellow/greenbluebrownblackgrey

black withnumber mark on cores

orblack with number mark

on cores andyellow/green core in the

outer cover

Page 50: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 50/430

49

L O W

V O L T A G E P O W

E R C A B L E S

E L K A B E L

Construction data U 1000 ¿R2V 0.6/1 kV

Number ofconductorsand nominal

cross

section

Shape

Outercable

diameterapprox.

Al weightCable

weightapprox.

N ı mm2 mm kg/km kg/km

Construction data U 1000 ¿R2V 0.6/1 kV

Number ofconductorsand nominal

cross

section

Shape

Outercable

diameterapprox.

Al weightCable

weightapprox.

N ı mm2 mm kg/km kg/km

1ı10 re 9.2 28 821ı16 re 10.5 45 1061ı25 re 12.5 68 1391ı35 re 13.5 95 1701ı50 rm 15.0 127 192

1ı70 rm 17.0 190 2831ı95 rm 19.0 260 361

1ı120 rm 21.0 325 4401ı150 rm 23.0 405 5071ı185 rm 25.5 510 6421ı240 rm 28.5 665 827

2ı2.5 re 10.5 14 1412ı4 re 11.5 23 1732ı6 re 12.6 34 220

2ı10 re 14.3 56 2842ı16 re 16.0 90 3732ı25 re 20.3 137 522

3ı2.5 re 11.0 21 1543ı4 re 12.1 36 1863ı6 re 13.2 51 238

3ı10 re 14.9 85 3083ı16 re 17.0 135 405

3ı25 re 21.9 210 5753ı35 re 23.1 290 703

3ı50 rm 27.0 385 8253ı70 sm 31.3 585 12053ı95 sm 35.8 810 1620

3ı120 sm 39.6 1020 19753ı150 sm 44.0 1255 23503ı185 sm 49.0 1560 30123ı240 sm 55.6 2035 3903

3G2.5 re 11.0 21 1543G4 re 12.1 36 186

3G6 re 13.2 51 2383G10 re 14.9 85 3083G16 re 17.0 135 4053G25 re 21.9 210 575

3x50+35 rm/rm 29.3 480 9153x70+50 sm/rm 34.2 680 12543x95+50 sm/rm 38.2 910 1620

3x120+70 sm/rm 42.8 1180 20873x150+70 sm/rm 46.9 1405 24033x185+70 sm/rm 51.8 1750 30103x240+95 sm/rm 58.5 2295 3931

Construction data U 1000 ¿R2V 0.6/1 kV

Number ofconductorsand nominal

crosssection

Shape

Outercable

diameterapprox.

Al weightCable

weightapprox.

N ı mm2 mm kg/km kg/km

Construction data U 1000 ¿R2V 0.6/1 kV

Number ofconductorsand nominal

crosssection

Shape

Outercable

diameterapprox.

Al weightCable

weightapprox.

N ı mm2 mm kg/km kg/km

4ı2.5 re 11.6 28 1444ı4 re 13.2 46 1664ı6 re 14.3 68 268

4ı10 re 16.5 112 3544ı16 re 18.7 180 4664ı25 re 22.6 270 655

4G2.5 re 11.6 28 1444G4 re 13.2 46 166

4G6 re 14.3 68 2684G10 re 16.5 112 3544G16 re 18.7 180 4664G25 re 22.6 270 6554G35 re 25.3 390 817

4G50 rm 29.7 520 9534G70 sm 34.7 760 14004G95 sm 39.6 1060 1830

4G120 sm 44.0 1340 23274G150 sm 49.0 1650 2765

4G185 sm 55.0 2100 36204G240 sm 62.1 2720 4680

5G2.5 re 12.7 35 1955G4 re 14.3 58 2365G6 re 15.4 85 307

5G10 re 18.2 140 4105G16 re 20.4 225 5405G25 re 25.3 345 765

7G2.5 re 13.7 49 2018G2.5 re 14.9 56 224

10G2.5 re 17.0 70 27012G2.5 re 17.6 84 29614G2.5 re 18.7 98 323

19G2.5 re 20.9 133 40024G2.5 re 24.2 168 48230G2.5 re 25.3 210 57037G2.5 re 27.5 260 662

Al conductors XLPE insulation PVC sheath

Page 51: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 51/430

Cable design

Construction According to NBN C 33-322

Conductor Cu according to NBN C 33-322(IEC 60228):-rm class 1 1.5 to 16mm2

-rm class 2 1.5 to 500mm2

Insulation XLPE compound

Innersheath tape or extrusion

Sheath PVC compound

Color black

Technical data

50

Application

These cables are used for distribution and supply of consumers with electrical power with nominal voltage 0.6/1kV andfrequency 50 Hz in industrial installations and urban networksThey are suitable for fixed indoor assembly in cable ducts, tunnels and conduits, over shelves and grilles, directlyunderground in ditch and outdoor under shelters providing the conditions determined for the type of cable.

L O W

V O L T A

G E P O W E R C A

B L E S

E L K A B E L

EXVBUo/U - 0.6/1 kV

NBN C 33-322 / NBN C 30-004

Construction data EXVB 0.6/1 kV

Number of conductors andnominal cross

sectionShape Cable diameter

approx. Cu weight Cable weightapprox.

N ı mm2 mm kg/km kg/km

Color coding Construction Core color

4ı Blue / brown / black / black

Cu conductors XLPE insulation PVC filling PVC sheath

Conductor resistance

at 20∞—:IEC 60228

Operating temperature 90∞C continuous operation

Overload temperature 130∞C /100h/per year χı./

Short circuit temperature 250∞C /5 s max./

Nominal voltage Uo/U: 0.6/1 kV

Highest system voltage 1.2 kV

Temperature range

laying and installing

exploitation and storage

-5∞C to +60∞C

-25∞C to +70∞C

Bending radius, min.

approx.12 x D cable

4ı10 re 18.5 363 6954ı16 rm 21.0 592 10024ı25 rm 25.5 925 1445

Page 52: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 52/430

51

L O W

V O L T A G E P O W

E R C A B L E S

E L K A B E L

Uo/U - 0.6/1 kVIEC 60502-1 and BS 7889/97

Cu conductors XLPE insulation PVC sheath

Application

These cables are used for distribution and supply of consumers with electrical power with nominal voltage 0.6/1kV andfrequency 50 Hz in industrial installations and urban networks.They are suitable for fixed indoor assembly in cable ducts, tunnels and conduits, over shelves and grilles, directlyunderground in ditch and outdoor under shelters providing the conditions determined for the type of cable.

Cable design

Construction According to IEC60502/BS7889/97

Conductor Cu wires,class 2 according toBS 6360 IEC 60228

Insulation XLPE, black

Sheath PVC compound

Color black

“ÂıÌ˘ÂÒÍË ‰‡ÌÌË

Construction data Cu/XLPE/PVC 0.6/1 kVNumber ofconductorsand nominal

crosssection

Shape

Outer

cablediameterapprox.

Cu weightCable

weightapprox.

N ı mm2 mm kg/km kg/km

Construction data Cu/XLPE/PVC 0.6/1 kVNumber ofconductorsand nominal

crosssection

Shape

Outer

cablediameterapprox.

Cu weightCable

weightapprox.

N ı mm2 mm kg/km kg/km

1x6 rm 7.3 55 921ı10 rm 8.2 93 1351ı16 rm 8.9 148 1911ı25 rm 10.5 229 2851ı35 rm 11.6 325 376

1ı50 rm 13.6 458 5401ı70 rm 15.6 648 7501ı95 rm 17.5 885 1010

1ı120 rm 19.2 1120 12501ı150 rm 21.3 1378 15301ı185 rm 23.4 1703 1900

1ı240 rm 26.3 2208 24701x300 rm 29.0 2765 30801x400 rm 32.7 3680 38901x500 rm 36.6 4600 49701x630 rm 41.3 5890 6370

Conductor resistanceat 20∞—:

According to NF C 32-321

Operating temperature 90∞C continuous operation

Overload temperature 130∞C /100h/per year χı./

Short circuit temperature 250∞C /5 s max./

Nominal voltage Uo/U: 0.6/1 kV

Highest system voltage 1.2 kV

Temperature rangelaying and installing

exploitation and storage-5∞C to +60∞C-25∞C to +70∞C

Bending radius, min.approx.

10 x D cable

Page 53: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 53/430

Cable construction

Construction According to BS 5467-97Conductor —u wires stranded according to

BS 6360 ( IEC 60228 ) class 2Insulation XLPE compound type GP 8

specified in BS 7655

Colors 2-cores - brown; blue3-cores - brown; black; grey4-cores - brown; black; grey; blue5-cores - brown; black; grey;

green /yellow; blueControl - black with white numbersor white with black numbers

Inner sheath polymer compound

Armour galvanized steel wires , appliedhelically

Sheath PVC compound according to type 9specified in BS 7655

Color black

Technical data

Conductor resistance

at 20∞—

According to BS 6360

(IEC228) class 2

Operating temperature

max.90∞— continuous operation

Overload temperature 130∞C /100h/per year χı./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U 0.6/1 kV

Highest system voltage 1.2 kV

Test voltage AC - 5 min

between cores - 3.5 ÍV

between core and screen -

3.5 ÍV

Bending radius, min.

- circular cores- sector

- 6x D cable- 8ı D cable

Temperature of laying no less than 0∞—

Temperature of

exploitation - 30 to 50∞—

Force of strain in laying N

max.

Cu cores - 50*n*S core

-n-number of cores

and

-S-nominal cross sec-

tion of cores in mm

52

Application

The power and control cables with cross-linked polyethylene (XLPE) armored with galvanized steel wires are used in

electrical installations with nominal voltage Uo/U 0.6/1 kV. These cables are used in industrial installations and urbannetworks.These cables are for fixed assembly in lines with unlimited difference levels, for laying in industrial installations, in cableducts, tunnels and conduits, over shelves and grilles outdoor under shelters.

L O W

V O L T A

G E P O W E R C A

B L E S

E L K A B E L

Cu /X L P E /P VC /S W A/P VC Uo/U - 0.6/1 kVBS 5467-1997

Page 54: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 54/430

53

L O W

V O L T A G E P O W

E R C A B L E S

Cu conductors XLPE insulation PVC sheath Armour PVC sheath

E L K A B E L

Construction data Cu/XLPE/PVC/SWA/PVC 0.6/1 kV

Number of conduc-tors and nominal

cross section

Thickness ofinsulation

Nominal steelarmour wire

diameter

Thickness ofoversheath

Cable diameterapprox.

Mass ofCu

approx.

Cable weightapprox.

N ı mm2 mm mm mm mm kg/km kg/km

2x1.5 rm2x2.5 rm2x4.0 rm2x6.0 rm2x10 rm2x16 rm2x25 rm2x35 rm3x1.5 rm3x2.5 rm3x4.0 rm3x6.0 rm3x10 rm3x16 rm3x25 rm3x35 rm4x1.5 rm4x2.5 rm4x4.0 rm4x6.0 rm4x10 rm4x16 rm4x25 rm4x35 rm4x35 sm4x50 sm4x70 sm4x95 sm

4x120sm4x150 sm4x185 sm5x1.5 rm5x2.5 rm5x4.0 rm5x6.0 rm5x10 rm5x16 rm5x25 rm5x35 rm7x1.5rm

12x1.5 rm19x1.5 rm27x1.5 rm

37x1.5 rm7x2.5 rm12x2.5 rm19x2.5 rm27x2.5 rm37x2.5 rm7x4.0 rm

12x4.0 rm19x4.0 rm27x4.0 rm37x4.0 rm

0.60.70.70.70.70.70.90.90.60.70.70.7

0.70.70.90.90.60.70.70.70.70.70.90.90.91.01.11.11.21.41.60.60.70.70.70.70.70.90.90.60.60.60.6

0.60.70.70.70.70.70.70.70.70.70.7

0.90.90.90.90.91.251.251.60.90.90.90.9

1.251.251.61.60.90.90.91.251.251.251.61.61.61.62.02.02.52.52.50.90.90.91.251.251.601.601.600.91.251.251.6

1.60.91.251.61.61.61.251.61.61.62.0

1.31.41.41.41.51.51.61.71.31.41.41.4

1.51.61.71.81.31.41.41.51.51.61.71.81.81.92.12.22.42.62.61.41.41.51.51.61.71.81.91.41.51.61.7

1.71.41.61.71.81.81.51.61.71.92.0

12.112.914.715.918.021.926.729.212.814.115.818.0

21.223.128.230.813.315.016.418.721.123..428.933.728.632

37.741.747.151.456.614.316.319.020.925.828.433.536.615.218.521.126.7

29.017.122.426.630.733.819.725.729.334.4.39.2

284675

1101823034706524269

1101652754507009805592

146218363592925

13031303185726013540446055756880

69114182275455745

11651640

96165260373

506160525590621845258442700994

1362

272337407491655955

12631732301379457558

863126719562118331426525754

10051326203725292332296541995368689982279943383487622873

1180175224503044434737946

1385

1659564960

144018542253808

1403185424303316

Page 55: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 55/430

Cable construction

Construction According to BS 5467-97

Conductor —u stranded wires according to BS6360 (IEC 60228) class 2

Insulation XLPE compound, black and red

Inner sheath PVC compound

Armour non-magnetic ¿l wires, laidconcentrically

Sheath PVCcompound type 9

Color black

Technical data

54

Application

The single-core power cables with insulation of cross-linked polyethylene (XLPE) type LSOH are flame retardant, withlow halogen free smoke emission and corrosion at fire conditions and are suitable for use in electrical installations fornominal voltage Uo/U 0.6/1 kV. Cables are designed with sheath, which does not contain halogen materials, flameretardant, free smoke emission and corrosion, and non-magnetic armor of ¿l wires. They are suitable for use in distri-bution networks, electrical power stations and substations. These cables are for fixed assembly in lines with unlimiteddifference levels, for laying in industrial sites, indoor installations, in cable ducts, conduits and shafts, over shelves andgrills directly underground in ditch and outdoor shelter.

L O W

V O L T A

G E P O W E R C A

B L E S

E L K A B E L

Cu /X L P E /P VC /AW A/P VC Uo/U - 0.6/1 kVBS 5467-1997

Conductor resistanceat 20∞—

According to BS 6360(IEC 60228) class 2

Operating temperaturemax.

90∞— continuous operation

Overload temperature 130∞— /100h/per year χı./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U 0.6/1 kV

Highest system voltage 1.2 kV

Test voltage AC - 5 min

Bending radius, min.Temperature of laying

Between core and screen -3.5kV

6x D cableno less than 0∞—

Temperature of exploita-tion - 30 to 50∞—

Force of strain in laying Nmax.

Cu cores- 50*n*Scoren-number of cores andS-nominal cross-section of

cores in mm

Construction data Cu/XLPE/PVC/AWA/PVC

Number of conduc-tors and nominal

cross section

Thickness ofinsulation

Diameter of Al wires in armor

Thickness ofsheath

Cable diameterapprox.

Mass ofCu

approx

Cable weightapprox.

N ı mm2 mm mm mm mm kg/km kg/km

1x150rm1x185 rm1x240 rm

1x300 rm1x400 rm1x500 rm

1.41.61.7

1.82.02.2

1.61.61.6

1.62.02.0

1.71.81.8

1.92.02.1

26.328.731.4

34.138.942.8

137817032208

276536804600

172421132696

330542865381

Cu conductors XLPE insulation PVC sheath Armour Al wires PVC sheath

Page 56: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 56/430

P O WE R C A B L E S F O R

O V E R H E A

D L I N E S

E L K A B E L

Page 57: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 57/430

Cable construction

Construction According to VDE 0276-626/4FConductor FN KI 02.003-96

-phase (main) Ã Al stranded compacted orNon-compacted according toVDE 0276-626

-additionalfor lighting R Al stranded compacted or

Non-compacted according toVDE 0276-626

Insulation XLPE with min. 2% carbon blackcontent type TIX-2

Cable lay up constructions twisted into a(cable bundle include:constructions) - phase (main) insulated cores(Ã)

- one, two, or three additionalreduced insulated cores forlighting ( R )

Color black

Marking for NFA2X - to VDE 0276-626for SAH-VO - to FN KI 02 003

Technical data

56

ApplicationThe power cables with XLPE insulation for overhead lines - self-supporting type are designed for transfer, distributionand supply with electrical power in networks low voltage Uo/U 0.6/1 kV.In constructions for distribution networks these cable permit suspension on fasades and trees.They allow crossing of forest areas without cutting and maintenance of openings in the wood.The suspension and support of the whole bundle is carried out by the phase ( basic ) insulated current-conductive.

L O W V O L T A G E P O W E

R C A B L E S F O R O V E R H E A D L I N E S - S E L F - S U P P O R T I N G T Y P E

NFA2X / /S¿H - VŒ

Uo/U - 0.6/1 kV VDE 0276-626/4F //

FN KI 02.003

Operating temperature

Short-circuit temperature

80∞—

130∞—

Nominal voltage ¿— Uo/U 0.6/1 kV

Highest system voltage AC, not more than 1.2 kV

Test voltage ¿C -5 min

DC - 15 min

4 kV

10 kV

Bending radius, min.Temperature of laying

18xD cableno less than - 10∞—recommended 15∞—

Conductor resistance at20∞C

16 - 1.91 Ω/ÍÏ 50 - 0.641Ω/ÍÏ25 - 1.20 Ω/ÍÏ 70-0.443 Ω/ÍÏ

Breaking strengh min.

35 - 0.868Ω/ÍÏ 95 - 0.320Ω/ÍÏ16 - 2.84 kN 50 - 8.45 ÍN25 -4.17 kN 70 -11.32 ÍN35 - 5.78 kN 95 - 15.68 kN

E L K A B E L

Page 58: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 58/430

57

L O WV O L T A G E P O WE R C A B L E S F O R O V E R H E A D L I N E S - S E L F - S U P P O R T I N G T

Y P E

Construction data NFA2X / SAH-VO 0.6/1 kV

Number of conductorsand nominal cross

section

Diameter of bundleapprox. Mass of

¿l coresapprox.

Cable weightapprox.

Allowed cur-rent in powersupply net-

works

Allowed currentat short-circuit

N ı mm2 mm kg/km kg/km A kA

1x161x251x351x501x701x95

2x16

2x252x352x50

4x164x254x354x504x704x95

4x25+1x164x25+2x16

4x35+1x164x35+2x16

4x35+1x254x35+2x254x50+1x164x50+2x164x50+1x254x50+2x254x50+1x354x50+2x35

4x70+1x164x70+2x164x70+1x254x70+2x254x70+1x354x70+2x35

4x95+1x164x95+2x164x95+1x254x95+2x254x95+1x354x95+2x35

9,010,011,012,514,016,0

18,0

20,022,025,0

19,020,025,028,032,044,0

25,028,0

28,031,029,032,030,034,031,035,032,036,0

35,038,036,038,036,040,0

41,044,042,045,042,046,0

446797

137187267

91

139196281

181278397562764

1091

323368

442487

453536607652631700661760

810855834903854963

113611811160123011901289

74103133185242333

152

210272277

303421543753986

1358

496572

619695645754829905858964889

1025

106111371091119611211257

143415101463156914941630

81107132162205245

81

107132162

81107132162205243

107107

132132132132162162162162162162

205205205205205205

245245245245245245

0,81,31,92,73,85,2

0,8

1,31,92,7

0,81,31,92,73,85,2

1,31,3

1,91,9

1,91,92,72,72,72,72,72,7

3,83,83,83,83,83,8

5,25,25,25,25,25,2

Mass approx.

Al conductors XLPE insulation

E L K A B E L

Page 59: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 59/430

58

L O W

V O L T A

G E P O W E R C A

B L E S

F O

R O V E R H E A D L I N E S W I T H S U P P O R T I N G N E U

T R A L

S¿H - VŒUo/U - 0.6/1 kV

FN KI 02.003

Application

The power cables with XLPE insulation for overhead lines - self-supporting type are designed for transfer, distribution

and supply with electrical power in networks low voltage Uo/U 0.6/1 kV.In constructions for distribution networks these cable permit suspension on fasades and trees.They allow crossing of forest areas without cutting and maintenance of openings in the wood.The suspension and support of the whole bundle is carried out by a supporting insulated neutral wire of aluminiumsteel conductor or of aluminium alloy.

Technical data

Operating temperature

Short-circuit temperature

Nominal voltage ¿—DC

80∞—

130∞—

Uo/U 0.6/1 kV0.9 kV

Highest system voltage AC, not more than 1.2 kV

Test voltage ¿C -5 minDC - 15 min

4 kV10 kV

Bending radius, min.

Temperature of laying

- 18xD cable

no less than - 10∞—recommended 15∞—

Conductor resistance at20∞C

16 - 1.91Ω/ÍÏ 50 - 0.641Ω/ÍÏ25 - 1.20Ω/ÍÏ 70 - 0.443Ω/ÍÏ35 - 0.868Ω/ÍÏ 95 - 0.320Ω/ÍÏ ¿— (Al/St) 71.5 - 0.470Ω/ÍÏ

Supported neutral break-

ing strength min.15.5 ÍN

Cable construction

Construction According to FN KI 02.003-96

Conductor Al stranded compacted or-phase(main) Ã Non-compacted according to FN

KI 02.003steel reinforced Al stranded

- neutral(supporting) N conductor or Al alloy conductor to

FN KI 02.003-additionalfor lighting R Al stranded compacted or non-

compacted accordingto FN KI 02 003

Insulation XLPE with min. 2% carbon black

Cable lay up constructions twisted into a bundleinclude: - phase (main) insulated cores(Ã)

- neutral supporting insulated core ( N )- one, two, or three additional

reduced insulated cores for lighting ( R )

Color black

Marking to FN KI 02.003

E L K A B E L

Page 60: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 60/430

59

L O W

V O L T A G E P O W

E R C A B L E S

F O R

O V E R H E A D L I N

E S WI T H S U P P

O R T I N G N E U T R

A L

Al conductors XLPE insulation

Construction data SAH-VO 0.6/1 kV

Construction, number andcross section

Diameter of bundleapprox.

Mass of ¿l coresapprox.

Cable weightapprox.

Allowed cur-rent in powersupply net-

works

Allowed cur-rent at short-

circuit

N ı mm2 mm kg/km kg/km A kA

3x25rm+71,5ASt/rm3x25rm+71,5ASt+1x16rm3x25rm+71,5ASt+2x16rm

3x35rm+71,5ASt3x35rm+71,5ASt+1x16rm3x35rm+71,5ASt+2x16rm

3x50rm+71,5ASt3x50rm+71,5ASt+1x16rm3x50rm+71,5ASt+2x16rm

3x70rm+71,5ASt3x70rm+71,5ASt+1x16rm3x70rm+71,5ASt+2x16rm

272727

313131

343434

404040

499544589

588633679

712757802

864909954

675751827

767843919

92510001076

109911751250

107107107

132132132

162162162

205205205

1,31,31,3

1,91,91,9

2,72,72,7

3,83,83,8

Mass approx.

E L K A B E L

Page 61: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 61/430

L O W

V O L T A

G E P O W E R C A

B L E S

F O

R O V E R H E A D L I N E S W I T H S U P P O R T I N G N E U

T R A L

Cable constructionConstruction According to NF C 33-209

Conductor Al stranded compacted orphase(main) Ã Non-compacted according to NF C

33-209

- neutral AL stranded according to(supporting) N NF C 33-209

-additional Al stranded compacted or non-for lighting R compacted according to NF C 33-

209

Insulation XLPE with min. 2% carbon black con

tentConstructions twisted into a bundleinclude:- phase (main) insulated cores(Ã)- neutral supporting insulated core ( N )- one, two, or three additionalreduced insulated cores for lighting ( R )

Color black

Marking: raised with paint:- phase ( Ã ) - with numbers 1;2;3- supporting 0 core( N )ELKABEL NF C 33-209additional cores for lighting( R ) - EP1 and EP2

60

Al /RUo/U - 0.6/1 kV

NF C 33-209

Application

The power cables with cross-linked polyethylene (XLPE) insulation for overhead lines are designed for electrical installa-tions with alternating power networks with nominal voltage Uo/U 0.6/1 kV or in direct power networks with maximumvoltage according to land 0.9 ÍV.The cables with supporting (bearing) zero conductors are used for building networks in city and urban areas and theself-supporting type cables are for building distribution networks in these areas.Cables for overhead installations may be used in different types of installations: on free hanging facades; betweenposts; on fixed facades; trees and poles. Interception of forest areas without the need of clearance and maintenance ofopenings is allowed.-Cables with supporting zero conductor, the whole bundle is suspended and carried by the supporting conductor,which is made of aluminum compound.- Self-supporting construction, suspension and carrying of the whole bundle is done by the phase insulated conduc-tors.Bundles can include one or two additional conductors for public lighting and control pair.

Technical dataConductor resistance at20∞C According to NF C 33-209

Operating temperature

Overload temperature

Short circuit temperature

90∞— continuous operation

130∞— /100h/per year χı./

250∞— /5 s max./

Nominal voltage ¿—DC

Uo/U 0.6/1 kV0.9 kV

Highest system voltage AC, not more than 1.2 kV

Test voltage:

¿C -15 minDC - 15 min

4 kV10 kV

between cores - 3.5 ÍVbetween core and armor - 3.5 ÍV

Bending radius, min.

Temperature of laying

- 18x D cableno less than - 10∞—recommended 15∞—

Resistance at 20∞—:16 -1.91Ω/ÍÏ 70-0.443Ω/ÍÏ

25 -1.20Ω/ÍÏ 95-0.320Ω/ÍÏ

35 - 0.868Ω/ÍÏ 120-0.253Ω/ÍÏ50 - 0.641Ω/ÍÏ 150-0.206Ω/ÍÏ54.6Alm-0.63Ω/ÍÏ;70Alm-.5Ω/ÍÏ

Supported neutral break-ing strength min.

95Alm - 0.343Ω/ÍÏÁ‡ 54.6 - 16.6ÍNÁ‡ 70 - 20.50kN

Á‡ 95 - 27.50ÍN

E L K A B E L

Page 62: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 62/430

61

L O W

V O L T A G E P O W

E R C A B L E S

F O R

O V E R H E A D L I N

E S WI T H S U P P

O R T I N G N E U T R

A L

Note: 1. "" - is the number of conductors for public electricity and can accept values of 0; 1; 2 or 3.2. Mass of core and cable are shown in =2

Construction data Al/R 0.6/1 kV

Number of conductorsand nominal cross

section

Thickness of insu-

lation M/N/R

Diameterof bundle

approx.

Allowed cur-rent in power

supply net- works

Allowed current indistribution net-

worksMass of

¿l coresapprox.

Cable

weightapprox.

N ı mm2 mm mm ¿ A kg/km kg/km

2x162x254x164x25

3x25+54.6Alm3x25+54.6Alm+Kx16

3x35+54.6Alm3x35+54.6Alm+Kx16

3x50+54.6Alm3x50+54.6Alm+Kx163x50+54.6Alm+Kx25

3x70+54.6Alm3x70+54.6Alm+Kx163x70+54.6Alm+Kx25

3x70+70Alm3x70+70Alm+Kx163x70+70Alm+Kx25

3x95+54.6Alm3x95+54.6Alm+Kx16

3x95+54.6Alm+Kx25

3x95+70Alm3x95+70Alm+Kx163x95+70Alm+Kx25

3x120+70Alm3x120+70Alm+Kx163x120+70Alm+Kx25

3x120+95Alm3x120+95Alm+Kx163x120+95Alm+Kx25

3x150+70Alm

3x150+70Alm+Kx16

3x150+70Alm+Kx25

1.21.41.21.4

1.4/1.61.4/1.6/1.2

1.6/1.61.6/1.6/1.4

1.6/1.61.6/1.6/1.21.6/1.6/1.4

1.8/1.61.8/1.6/1.21.8/1.6/1.4

1.8/1.51.8/1.5/1.21.8/1.5/1.4

1.8/1.6/1.8/1.6/1.2

1.8/1.6/1.4

1.8/1.51.8/1.5/1.21.8/1.5/1.4

1.8/1.51.8/1.5/1.21.8/1.5/1.4

1.8/1.61.8/1.6/1.21.8/1.6/1.4

1.7/1.5/1.7/1.5/1.2

1.7/1.5/1.4

15181822

3030

3333

363636

374040

414141

4444

44

444444464646

474747

48

48

48

----

112112 / 83

138138 / 83

168168 / 93

168 / 111

213213 / 83

213 / 111

213213 / 83

213 / 111

258258 / 83

258 / 111

258258 / 83

258 / 111300

300 / 83300 /111

300300 / 83

300 / 111

344

344 / 83

344 / 111

walls/air/facades72 / 93 / 83

95 / 122 / 11163 / 83 / 75

83 / 111 / 99

--

--

---

---

---

--

-

------

---

--

-

91142183285

369460

455546

583674725

754845896

798889940

9671059

1110

101111021154122548281368

129613871439

1482

1573

1624

125165260395

505635

615745

725860925

95010801150

98411151185

11951325

1355

135516151485144515751610

153516601735

1670

1795

1870

¿l/R

Al conductors XLPE insulation

E L K A B E L

Page 63: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 63/430

Cable construction

Construction According to FN KI 02.004and SFS 5791/94

Conductor Al alloy conductor stranded compacted

-steel reinforced Al stranded compacted or stranded type AC

Insulation XLPE with min. 2% carbon black

Additional Longitudinal water blocking( ‚ ),element may be provided by agreement

between the manufacturer and thepurchaser

Color Black

Marking SAH-20 - to FN I 02 004SAHv-20 -to FN I 02 004 withlongitudinal water blocking

S¿’ - ÔÓ SFS 5791 /94

Technical data

Operating temperature

Short-circuit temperature

Nominal voltage 50Hz

90∞— in operation

250∞— max. 5sec.

to Uo/U 12/20 kV (6/10kV)

Highest system voltage

Um not more than24 kV

Test voltage 4kV / 5 min

Bending radius, min.

Temperature of laying

10xD cable

no less than - 20∞—recommended 15∞—

62

Application

Conductors with XLPE insulation for overhead lines, are designed for transfer and distribution of electrical power inoverhead electrical networks with nominal voltage to Uo/U/Um 12/20/24 kV and frequency 50 Hz.The main characteristics of overhead lines with XLPE insulation overhead conductors are low susceptibility to opera-tional failures when conductors strike against each other or when a tree is temporarily leaning on the line. Also thespace in the terrain required for the line is narrower, specially in casse of parallel lines.

C O

N D U C T O R S W I T

H X L P E I N S U L A T I O N F O R O V E R H E A D L I N E S T O 2 0 K V

SAH-20 / /SAXSAHv -20

Uo/U - 12/20 kVFN KI 02.004/06 /

/ SFS 5791/94

E L K A B E L

Page 64: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 64/430

63

C O N

D U C T O R S WI T H

X L P E I N S U L A T I O N F O R O V E R H E

A D L I N E S T O 2 0

K V NOTE: * Conductors type AC according to BDS 1133

Construction and electrical data

Nominal

cross-section of aconductor

Number ofstrands in aconductor

Nominal

diameter ofaconductor

Nominal

thicknessofcovering

Approxi-

mateoveralldiameter

Mass of

cableapprox.

Breaking

loadmin.

Resistan-ce at tem-perature

20∞—m‡ı

Currentcarryingcapacity

Short

circuitcurrentfor 1 s

mm2 N mm mm mm kg/km ÍN Ω/ÍÏ A kA

35Alm50Alm70Alm95Alm

120 Alm150 Alm

35/¿—rm50/¿—rm

70/¿—rm95/¿—rm

120/¿—rm150/¿—rm

*35/¿—rm*50/¿—rm*70/¿—rm*95/¿—rm

7777

1919

77

77

1919

7777

7.0±0.208.0±0.209.7±0.2511.3±0.312.8±0.314.2±0.3

7.0±0.208.0±0.209.7±0.2511.3±0.312.8±0.314.2±0.3

8.49.6

11.413.5

2.32.32.32.32.32.3

2.32.3

2.32.32.32.3

2.32.32.32.3

11.612.614.315.917.418.8

11.612.6

14.315.917.418.8

13.014.216.018.1

160200270350425510

205250

340450470590

245305405545

11.214.220.627.935.2

43.4

11.214.2

20.627.935.2

43.4

13.3817.0123.5932.98

0.9860.7200.4930.3630.2880.236

0.9860.720

0.4930.3630.2880.236

0.7780.5950.4220.301

195245300370425495

195245

300370425495

195245300370

3.24.356.85

8.908.11.7014.50

3.24.35

6.858.908.11.7014.50

3.24.356.85

8.908.

Al conductors XLPE insulation

E L K A B E L

Page 65: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 65/430

M I D D L

E V O L T A G

E P O W E R

C A B L E S

E L K A B E L

Page 66: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 66/430

MI D D L

E V OL T A G

E P OWE R

C A B L E S

E L K A B E L

Page 67: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 67/430

Cable construction

Construction According to IEC 60502and DIN VDE 0276-620

Conductor —u and Al stranded compacted,according to IEC 60228 class 2and VDE 0295 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- semi-conductive XLPE compoundconductive layer and semi-conductive tape or

extruded semi-conductive XLPEcompound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Separating layer Layer of plastic tape

Sheath PVC compoundtype ST2 according to IEC 60502type DMV 6 according to VDE0276

Color red

Technical data

66

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequency 50 Hz in urban and district electricalnetworks and for electrical supply of transformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

2XSY/N2XSYA2XSY/NA2XSY

Uo/U - 6/10 kV, 12/20 kV, 18/30kVEC 60502-2 / DIN VDE 0276-620

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltage

Uo/U, no more than

6/10; 12/20 kV

12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial discharge at2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 68: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 68/430

67

MI D D L E V OL T A G E P

OWE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PVC sheath

Construction data 2XSY/N2XSY, A2XSY/NA2XSY 6/10; 12/20; 18/30 kV

Number of con-ductors and

nominal cross

section

Thic-kness of

insulation

Thic-kness ofsheath

Nominalcross-

section of

screen

Cable diameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

6/10 kV

1x35rm/161x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/25

1x240rm/251x300rm/251x400rm/351x500rm/35

12/20 kV

1x35rm/161x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

18/30 kV

1x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

3,43,43,43,43,43,43,43,43,43,4

3,43,43,43,4

5,55,55,55,55,55,55,55,55,55,55,55,55,55,5

8888888888

2,52,52,52,52,52,52,52,52,52,5

2,52,52,52,5

2,52,52,52,52,52,52,52,52,52,52,52,52,52,5

2,52,52,52,52,52,52,52,52,52,5

1616161616

16*16*16*2525

25253535

1616161616

16*16*16*252525253535

16161616252525253535

23242627293032343032

34364043

2728303133343639343639414447

33353638394143464952

28293132343537393537

39414548

3233353638394144394144464952

38404143444648515457

493604793

1033125515071842236515961930

2454298038364807

493604793

10331255150718422365159619302454298038364807

604793

10331255159619302454298038364807

935107613121599185921552536312622392620

3210380047365795

11161264151218091995238527773466246928613466407150256127

1508176820782358275831633786442854256555

94127183254321394495649394495

64981210431374

94127183254321394495649394495649

81210431374

127183254321394495649812

10431374

176176176176176176176176265265

265265363363

176176176176176176176176265265265265363363

176176176176265265265265363363

712775878996

110112191366158713021450

1671189623072657

893964

107812061237144816071927153216911927216825962988

1208133414751600182219932246252429963417

2XSY, N2XSY A2XSY, NA2XSY

min max

E L K A B E L

Page 69: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 69/430

Cable construction

Construction According to IEC 60502and DIN VDE 0276-620

Conductor —u and Al stranded compacted,according to IEC 60228 class 2and VDE 0295 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- semi-conductive XLPE compoundconductive layer and semi-conductive tape or

extruded semi-conductive XLPEcompound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Separating layer Layer of plastic tape

Sheath PE compoundtype ST7 according to IEC 60502type DMP 2 according to VDE0276

Color black

Technical data

68

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequency 50 Hz in urban and district electricalnetworks and for electrical supply of transformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

2XS2Y/N2XS2YA2XS2Y/NA2XS2Y

Uo/U - 6/10 kV, 12/20 kV, 18/30kVIEC 60502-2 / DIN VDE 0276-620

Conductor resistance at

20∞C

According to BDS904

(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltage

Uo/U, no more than

6/10; 12/20 kV

12kV; 24kV kV

Test voltage Uo/U

AC (≈) - 5 min

DC (=) - 15 min

6/10; 12/20 kV

15kV; 30kV kV

48kV; 96kV kV

Level of partial discharge

at 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC

15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 70: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 70/430

69

MI D D L E V OL T A G E P

OWE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PE sheath

Construction data 2XS2Y/N2XS2Y, A2XS2Y/NA2XS2Y 6/10; 12/20; 18/30 kV

Number of con-ductors and

nominal cross

section

Thic-kness of

insulation

Thickness of

sheath

Nominalcross-

section of

screen

Cable diameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

6/10 kV

1x35rm/161x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/25

1x240rm/251x300rm/251x400rm/351x500rm/35

12/20kV

1x35rm/161x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

18/30 kV1x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

3,43,43,43,43,43,43,43,43,43,4

3,43,43,43,4

5,55,55,55,55,55,55,55,55,55,55,55,55,55,5

8888888888

2,52,52,52,52,52,52,52,52,52,5

2,52,52,52,5

2,52,52,52,52,52,52,52,52,52,52,52,52,52,5

2,52,52,52,52,52,52,52,52,52,5

1616161616

16*16*16*2525

25253535

1616161616

16*16*16*252525253535

16161616252525253535

23242627293032343032

34364043

2728303133343639343639414447

33353638394143464952

28293132343537393537

39414548

3233353638394144394144464952

38404143444648515457

a493604793

1033125515071842236515961930

2454298038364807

493604793

10331255150718422365159619302454298038364807

604793

10331255159619302454298038364807

858995

12251506176120522427300821362511

3092367445985647

10231167140917011881226626523333235027363333393048725956

1394164819522226262230203635426252426352

94127183254321394495649394495

64981210431374

94127183254321394495649394495649812

10431374

127183254321394495649812

10431374

176176176176176176176176265265

265265363363

176176176176176176176176265265265265363363

176176176176265265265265363363

635694791903

100311151257146911991341

1553177021692508

800867975

10981124132914821793141315661793202624432818

1093121413491469168518502095235928133213

2XS2Y, N2XS2Y A2XS2Y, NA2XS2Y

min max

E L K A B E L

Page 71: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 71/430

Cable construction

Construction According to IEC 60502and DIN VDE 0276-620

Conductor —u and Al stranded compacted,according to IEC 60228 class 2and VDE 0295 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

and semi-conductive tape orextruded semi-conductive XLPEcompound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Separating layer Layer of plastic tape

Sheath PE compoundtype ST7 according to IEC 60502type DMP2 according to VDE 0276

Factory bundled three single-core cablesin TRIPLEX factory bindled in TRIPLEX

Color black

Technical data

70

Application

The three single-core cables with insulation of cross-linked polyethylene (XLPE) factory bindled in TRIPLEX, aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequen-cy 50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medi-um industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

2XS2Y- TR IPL E X /

N2XS2Y- TR IPL E X

A2XS2Y- TR IPL E X /

NA2XS2Y- TR IPL E X

Uo/U-6/10 kV, 12/20 kV, 18/30kVIEC 60502-2 / DIN VDE 0276-620

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 72: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 72/430

71

MI D D L E V OL T A G E P

OWE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PE sheath

Construction data2XS2Y- TRIPLEX / N2XS2Y- TRIPLEX, A2XS2Y- TRIPLEX / NA2XS2Y- TRIPLEX 6/10; 12/20; 18/30 kV

Number of conduc-tors and nominal

cross section

Thic-kness of

insulation

Thic-kness ofsheath

Nominalcross-

section ofscreen

Cable diameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass of

Cuapprox.

Mass of

cableapprox.

N ı mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

6/10 kV

3x(1x35rm /16)3x(1x50rm /16)3x(1x70rm /16)3x(1x95rm /16)

3x(1x120rm /16)3x(1x150rm /16)3x(1x185rm /16)3x(1x240rm /16)3x(1x150 rm /25)

3x(1x185rm /25)3x(1x240rm /25)3x(1x300rm /25)

12/20 kV

3x(1x35rm /16)3x(1x50rm /16)3x(1x70rm /16)3x(1x95rm /16)

3x(1x120rm /16)3x(1x150rm /16)3x(1x185rm /16)3x(1x240rm /16)3x(1x150 rm /25)3x(1x185rm /25)3x(1x240rm /25)

18/30 kV

3x(1x50rm /16)3x(1x70rm /16)3x(1x95rm /16)

3x(1x120rm /16)3x(1x150 rm /25)3x(1x185rm /25)

3,43,43,43,43,43,43,43,43,4

3,43,43,4

5,55,55,55,55,55,55,55,55,55,55,5

8,08,08,08,08,08,0

2,52,52,52,52,52,52,52,52,5

2,52,52,5

2,52,52,52,52,52,52,52,52,52,52,5

2,52,52,52,52,52,5

1616161616

16*16*16*25

252525

1616161616

16*16*16*252525

161616162525

49.651.856.258.362.664.869.173.464.8

69.173.477.8

58.360.564.867.071.373.477.884.273.477.884.2

71.375.677.882.184.288.6

60.562.667.069.173.475.679.984.275.6

79.984.288.6

69.171.375.677.882.184.288.695.084.288.695.0

82.186.488.692.995.099.4

147918122379309937654521552670954788

579073628940

14791812237930993765452155267095478857907362

181223793099376547885790

257429853675451852836156728190246408

7533927611022

30693501422751035643679879569999705082089999

418249445856667878669060

282381549762963

1182148519471182148519472436

282381549762963

118214851947118214851947

381549762963

11821485

528528528528528528528528795

795795795

528528528528528528528528795795795

528528528528795795

190520822373270930093345377144073597

402346595310

24002601292532943372398744465379423946985379

327936424047440750555550

2XS2Y- TRIPLEX

N2XS2Y- TRIPLE

A2XS2Y- TRIPLEX

NA2XS2Y- TRIPLEX

min max

E L K A B E L

Page 73: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 73/430

Cable constructionConstruction According to IEC 60502-2

DIN VDE 0276-620

Conductors —u and Al stranded compacted,according to IEC 60228 class 2and VDE 0295 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Water resisting -I option - water absorbing insulatingelement tape

-II option - water absorbing powderand a layer of plastic tape

Sheath PE compoundtype ST7 according to IEC 60502

type DMP 2 according to VDE0276

Color Black

Technical data

72

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking elements aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequen-cy 50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medi-um industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduits

and shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

2XS(F)2Y/

N2XS(F)2Y

A2XS(F)2Y/

NA2XS(F)2Y

Uo/U - 6/10 kV, 12/20 kV, 18/30kVIEC 60502-2 / DIN VDE 0276-620

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltage

Uo/U, no more than

6/10; 12/20 kV

12kV; 24kV kVTest voltage Uo/U

AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 74: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 74/430

73

MI D D L E V OL T A G E P

OWE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PE sheath

Construction data 2XS(F)2Y/N2XS(F)2Y, A2XS(F)2Y/NA2XS(F)2Y 6/10; 12/20; 18/30 kV

Number of con-ductors and

nominal cross

section

Thic-kness of

insulation

Thic-kness ofsheath

Nominalcross sec-

tion of

screen

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

6/10 kV

1x35rm/161x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/25

1x240rm/251x300rm/251x400rm/351x500rm/35

12/20 kV

1x35rm/161x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

18/30 kV1x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

3,43,43,43,43,43,43,43,43,43,4

3,43,43,43,4

5,55,55,55,55,55,55,55,55,55,55,55,55,55,5

8888888888

2,52,52,52,52,52,52,52,52,52,5

2,52,52,52,5

2,52,52,52,52,52,52,52,52,52,52,52,52,52,5

2,52,52,52,52,52,52,52,52,52,5

1616161616

16*16*16*2525

25253535

1616161616

16*16*16*252525253535

16161616252525253535

23242627293032343032

34364043

2728303133343639343639414447

33353638394143464952

28293132343537393537

39414548

3233353638394144394144464952

38404143444648515457

493604793

1033125515071842236515961930

2454298038364807

493604793

10331255150718422365159619302454298038364807

604793

10331255159619302454298038364807

906104312791564182221162495308122002579

3165375246835738

10811228147317681952234027303416242428143416401849666073

1465172220302308270731093728436153476482

94127183254321394495649394495

64981210431374

94127183254321394495649394495649812

10431374

127183254321394495649812

10431374

176176176176176176176176265265

265265363363

176176176176176176176176265265265265363363

176176176176265265265265363363

683745846961

106411801325154212641409

1626184922542599

858927

103911651194140315601876148716441876211425372919

1164128914271550177019392189245829183343

2XS(F)2Y, N2XS(F)2Y A2XS(F)2Y, NA2XS(F)2Y

min max

E L K A B E L

Page 75: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 75/430

Cable constructionConstruction According to IEC 60502-2

DIN VDE 0276-620

Conductors —u and Al stranded compacted,according to IEC 60228 class 2 andVDE 0295 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Water resisting -I option - water absorbing insulatingelement tape

-II option - water absorbing powderand a layer of plastic tape

Sheath PE compoundtype ST7 according to IEC 60502type DMP 2 according to VDE0276

Color Black

Factory bundled three single-core cablesin TRIPLEX factory bindled in TRIPLEX

Technical data

74

Application

The three single-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking ele-ments, factory bindled in TRIPLEX, are designed for transfer and distribution of electrical power with nominal voltageUo/U 6/10; 12/20; 18/30 kV and frequency 50 Hz in urban and district electrical networks and for electrical supply oftransformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

2XS(F )2Y -TRIPLEX /

N2XS(F )2Y -TRIPLEX

A2XS(F )2Y -TRIPLEX /

NA2XS(F )2Y -TRIPLEX

Uo/U - 6/10 kV, 12/20 kV, 18/30kVIEC 60502-2 / DIN VDE 0276-620

Conductor resistance at20∞C

According to IEC60228 class 2and VDE 0295 class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10; 12/20; 18/30 kV

Highest system voltageUo/U, no more than

6/10; 12/20; 18/30 kV12kV; 24kV; 36kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20; 18/30kV21kV; 42kV; 63kV67kV; 134kV; 201kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC / 2 pC15x D cable

no less than - 20∞—

Temperature of exploitationTests

-30 to 50∞—according to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying N

max. Al cores - 30*n*S coreCu cores - 50*n*S core

where:

Tests - water penetration inthe region of metallicscreen

N is number of cores andS is cross section of cores inmm

IEC 60502-2 annex F

E L K A B E L

Page 76: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 76/430

75

MI D D L E V OL T A G E P

OWE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PE sheath

Construction data2XS(F)2Y- TRIPLEX / N2XS(F)2Y- TRIPLEX, A2XS(F)2Y- TRIPLEX / NA2XS(F)2Y- TRIPLEX Uo/U 6/10; 12/20; 18/30 kV

Number of conduc-

tors and nominalcross section

Thic-

kness ofinsulation

Thic-

kness ofsheath

Nominalcross

section ofscreen

Cable diameterapprox.

Mass ofCuapprox.

Mass ofcableapprox.

Mass of Al

approx.

Mass of

Cuapprox.

Mass of

cableapprox.

N ı mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

6/10 kV

3x(1x35rm /16)3x(1x50rm /16)3x(1x70rm /16)3x(1x95rm /16)

3x(1x120rm /16)3x(1x150rm /16)3x(1x185rm /16)3x(1x240rm /16)3x(1x150 rm /25)

3x(1x185rm /25)3x(1x240rm /25)3x(1x300rm /25)

12/20 kV

3x(1x35rm /16)3x(1x50rm /16)3x(1x70rm /16)3x(1x95rm /16)

3x(1x120rm /16)3x(1x150rm /16)3x(1x185rm /16)3x(1x240rm /16)3x(1x150 rm /25)3x(1x185rm /25)3x(1x240rm /25)

18/30 kV3x(1x50rm /16)3x(1x70rm /16)3x(1x95rm /16)

3x(1x120rm /16)3x(1x150 rm /25)3x(1x185rm /25)

3,43,43,43,43,43,43,43,43,4

3,43,43,4

5,55,55,55,55,55,55,55,55,55,55,5

8,08,08,08,08,08,0

2,52,52,52,52,52,52,52,52,5

2,52,52,5

2,52,52,52,52,52,52,52,52,52,52,5

2,52,52,52,52,52,5

1616161616

16*16*16*25

252525

1616161616

16*16*16*252525

161616162525

49.751.856.258.362.664.869.173.464.8

69.173.477.8

58.360.564.866.971.373.477.884.273.477.884.2

71.375.677.882.184.388.6

60.562.667.069.273.475.679.984.375.6

79.984.288.6

69.271.375.677.882.284.388.695.184.388.695.1

82.186.488.692.995.199.4

147918122379309937654521552670954788

579073628940

14791812237930993765452155267095478857907362

181223793099376547885790

271831293837469254666348748592436600

7737949511256

3243368444195304585670208190

1024872728442

10248

439551666090692481219327

282381549762963

1182148519471182

148519472436

282381549762963

118214851947118214851947

381549762963

11821485

528528528528528528528528795

795795795

528528528528528528528528795795795

528528528528795795

204922352538288331923540397546263792

422748785547

25742781311734953582420946805628446149325628

349238674281465053105817

2XS(F)2Y- TRIPLEX

N2XS(F)2Y- TRIPLEX

A2XS(F)2Y- TRIPLEX

NA2XS(F)2Y- TRIPLEX

min max

E L K A B E L

Page 77: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 77/430

Cable constructionConstruction According to IEC 60502-2

DIN VDE 0276-620

Conductors —u and Al stranded compacted,according to IEC 60228 class 2 andVDE 0295 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Water resistingelement - water absorbing powder

Radial Al foil with copolymer protection from moisture ingress

Sheath layer

PE compound type ST7 according to IEC 60502-2type DMP 2 according to VDE 0276

Color Black

Technical data

76

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequency 50 Hz in urban and district electricalnetworks and for electrical supply of transformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

2XS(FL )2Y /

N2XS(FL )2Y

A2XS(FL )2Y /

NA2XS(FL )2Y

Uo/U - 6/10 kV, 12/20, 18/30kV,IEC 60502-2 / DIN VDE 0276-620

Conductor resistance at20∞C

According to IEC60228 class 2and VDE 0295 class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10; 12/20; 18/30 kV

Highest system voltageUo/U, no more than

6/10; 12/20; 18/30 kV12kV; 24kV; 36kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20; 18/30kV21kV; 42kV; 63kV67kV; 134kV; 201kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC / 2 pC15x D cable

no less than - 20∞—

Temperature of exploitationTests

-30 to 50∞—

according to IEC 60502-2 orDIN VDE 0276-620

Force of strain in laying Nmax.

Al cores - 30*n*S coreCu cores - 50*n*S core

where:

Tests - water penetration inthe region of metallicscreen

N is number of cores andS is cross section of cores inmm

IEC 60502-2 annex F

E L K A B E L

Page 78: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 78/430

77

MI D D L E V OL T A G E P

OWE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen Al foil PE sheath

Construction data2XS(FL)2Y / N2XS(FL)2Y, A2XS(FL)2Y / NA2XS(FL)2Y 6/10; 12/20; 18/30 kV

Number of conduc-tors and nominal

cross section

Thic-kness of

insulation

Thic-kness ofsheath

Nominalcross

section ofscreen

Cable diameterapprox.

Mass ofCuapprox.

Mass ofcableapprox.

Mass of Al

approx.

Mass of

Cuapprox.

Mass of

cableapprox.

N x mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

6/10 kV1x35rm/161x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/161x185rm/161x240rm/161x150rm/25

1x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

12/20 kV

1x35rm/161x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

18/30 kV

1x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

3,43,43,43,43,43,43,43,43,4

3,43,43,43,43,4

5,55,55,55,55,55,55,55,55,55,55,55,55,55,5

8888888888

2,52,52,52,52,52,52,52,52,5

2,52,52,52,52,5

2,52,52,52,52,52,52,52,52,52,52,52,52,52,5

2,52,52,52,52,52,52,52,52,52,5

1616161616

16*16*16*25

2525253535

1616161616

16*16*16*252525253535

16161616252525253535

232426272930323430

3234364043

2728303133343639343639414447

33353638394143464952

282931323435373935

3739414548

3233353638394144394144464952

38404143444648515457

493604793

103312551507184223651596

19302454298038364807

493604793

1033125515071842236515961930

2454298038364807

604793

10331255159619302454298038364807

90610431279156418222116249530812200

25793165375246835738

10811228147317681952234027303416242428143416401849666073

1465172220302308270731093728436153476482

94127183254321394495649394495649812

10431374

94127183254321394495649394495

649812

10431374

127183254321394495649812

10431374

176176176176176176176176265

265265265363363

176176176176176176176176265265265265363363

176176176176265265265265363363

683745846961

10641180132515421264

14091626184922542599

858927

103911651194140315601876148716441876211425372919

1164128914271550177019392189245829183343

2XS(FL)2Y,

N2XS(FL)2Y A2XS(FL)2Y,NA2XS(FL)2Y

min max

E L K A B E L

Page 79: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 79/430

Cable constructionConstruction According to IEC 60502-2

DIN VDE 0276-620

Conductors —u and Al stranded compacted,according to IEC 60228 class 2 andVDE 0295 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Water resistingelement - water absorbing powder

Radial Al foil with copolymer protection from moisture ingress layer

Sheath PE compoundtype ST7 according to IEC 60502-2type DMP 2 according to VDE 0276

Color Black

Factory bundled three single-core cablesin TRIPLEX factory bindled in TRIPLEX

Technical data

78

Application

The three single-core cables with insulation of cross-linked polyethylene (XLPE) factory bindled in TRIPLEX, aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequen-cy 50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medi-um industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

2XS(FL )2Y - TR IPL E X /

N2XS(FL )2Y - TR IPL E X

A2XS(FL )2Y - TR IPL E X /

NA2XS(FL )2Y - TR IPL E X

Uo/U - 6/10 kV, 12/20, 18/30kV,IEC 60502-2 / DIN VDE 0276-620

Conductor resistance at20∞C

According to IEC60228 class 2and VDE 0295 class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10; 12/20; 18/30 kV

Highest system voltageUo/U, no more than

6/10; 12/20; 18/30 kV12kV; 24kV; 36kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20; 18/30kV21kV; 42kV; 63kV67kV; 134kV; 201kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC / 2 pC15x D cable

no less than - 20∞—

Temperature of exploitationTests

-30 to 50∞—according to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying N

max. Al cores - 30*n*S coreCu cores - 50*n*S core

where:

Tests - water penetrationin the region of metallicscreen

N is number of cores andS is cross section of cores inmm

IEC 60502-2 annex F

E L K A B E L

Page 80: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 80/430

79

MI D D L E V OL T A G E P

OWE R C A B L E S

Cu or Al conductors XLPE insulation Cu screen Al foil PE sheath

Construction data2XS(FL)2Y- TRIPLEX / N2XS(FL)2Y- TRIPLEX, A2XS(FL)2Y- TRIPLEX / NA2XS(FL)2Y- TRIPLEX Uo/U 6/10; 12/20; 18/30 kV

Number of conduc-tors and nominal

cross section

Thic-kness of

insulation

Thic-kness ofsheath

Nominalcross

section ofscreen

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.

Mass of

Alapprox.

Mass ofCu

approx.

Mass of

cableapprox.

N ı mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

6/10 kV

3x(1x35rm /16)3x(1x50rm /16)3x(1x70rm /16)3x(1x95rm /16)

3x(1x120rm /16)3x(1x150rm /16)3x(1x185rm /16)3x(1x240rm /16)3x(1x150 rm /25)

3x(1x185rm /25)3x(1x240rm /25)3x(1x300rm /25)

12/20 kV

3x(1x35rm /16)3x(1x50rm /16)3x(1x70rm /16)3x(1x95rm /16)

3x(1x120rm /16)3x(1x150rm /16)3x(1x185rm /16)3x(1x240rm /16)3x(1x150 rm /25)3x(1x185rm /25)3x(1x240rm /25)

18/30 kV

3x(1x50rm /16)3x(1x70rm /16)3x(1x95rm /16)

3x(1x120rm /16)3x(1x150 rm /25)3x(1x185rm /25)

3,43,43,43,43,43,43,43,43,43,43,43,4

5,55,55,55,55,55,55,55,55,55,55,5

8,08,08,08,08,08,0

2,52,52,52,52,52,52,52,52,5

2,52,52,5

2,52,52,52,52,52,52,52,52,52,52,5

2,52,52,52,52,52,5

1616161616

16*16*16*25

252525

1616161616

16*16*16*252525

161616162525

49.751.856.258.362.664.869.173.464.869.173.477.8

58.360.564.866.971.373.477.884.273.477.884.2

71.375.677.882.184.388.6

60.562.667.069.273.475.679.984.375.6

79.984.288.6

69.271.375.677.882.284.388.695.184.388.695.1

82.186.488.692.995.199.4

147918122379309937654521552670954788579073628940

14791812237930993765452155267095478857907362

181223793099376547885790

27183129383746925466634874859243660077379495

11256

3243368444195304585670208190

1024872728442

10248

439551666090692481219327

282381549762963

1182148519471182148519472436

282381549762963

118214851947118214851947

381549762963

11821485

528528528528528528528528795

795795795

528528528528528528528528795795795

528528528528795795

204922352538288331923540397546263792422748785547

25742781311734953582420946805628446149325628

349238674281465053105817

2XS(FL)2Y- TRIPLEX

N2XS(FL)2Y- TRIPLEX

A2XS(FL)2Y- TRIPLEX

NA2XS(FL)2Y- TRIPLEX

min max

E L K A B E L

Page 81: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 81/430

Cable constructionConstruction According to IEC 60502

and DIN VDE 0276-620

Conductor —u and Al stranded compacted,according to IEC 60228 class 2and VDE 0295 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

and semi-conductive tape orextruded semi-conductive XLPEcompound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm or Cu tapeslaid with overlap over each phase

Cable assembly Three insulated and screenesdphases are twisted with fillings andtape support

Inner sheatth PVC compound

Sheath PVC compoundtype ST2 according to IEC 60502type DMV 6 according to VDE0276

Color red

Technical data

80

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequency 50 Hz in urban and district electricalnetworks and for electrical supply of transformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A B L E S - T H R E E C O R E

2XS≈Y/

N2XS≈Y

A2XS≈Y/

NA2XS≈Y

Uo/U - 6/10 kV, 12/20 kV, 18/30kVIEC 60502-2 / DIN VDE 0276-620

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature of

exploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 82: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 82/430

81

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen PVC sheath

Construction data

2XSEY/N2XSEY, A2XSEY/NA2XSEY 6/10; 12/20; 18/30 kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion ofscreen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of Alapprox.

Ç҇ ̇

͇·Â·ÔË·Î.

N x mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

6/10 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /253x185rm /253x240rm /253x300rm /25

12/20kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /253x185rm /253x240rm /25

18/30 kV3x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /25

3,43,43,43,43,43,43,43,43,4

5,55,55,55,55,55,55,55,5

88888

2,52,52,72,82,93,03,23,43,5

2,82,93,03,13,23,43,53,7

3,33,43,53,7

3,8

161616161625252525

1616161616252525

1616161625

46,448,853,057,160,364,268,574,379,6

56,759,363,367,470,674,778,884,5

71,775,879,883,387,1

101013631968273234404245531169818661

10101363196827323440424553116981

13631968273234404245

2907340842795308619573838741

1081712906

3793434552486331727585669968

12155

5624661077918819

10185

298404584809

10231257157920712589

298404584809

1023125715792071

404584809

10231257

223124972965348138994545519561537138

31173434393445044979572864227491

47135296596465237347

2XSEY, N2XSEY A2XS≈Y, NA2XSEY

E L K A B E L

Page 83: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 83/430

Cable constructionConstruction According to IEC 60502

and DIN VDE 0276-620

Conductor —u and Al stranded compacted,according to IEC 60228 class 2and VDE 0295 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

and semi-conductive tape orextruded semi-conductive XLPEcompound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm or Cu tapeslaid with overlap over each phase

Cable assembly Three insulated and screenesdphases are twisted with fillings andtape support

Inner sheatth PVC compound

Sheath PE compoundtype ST7 according to IEC 60502type DMP 2 according to VDE0276

Color Black

Technical data

82

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequency 50 Hz in urban and district electricalnetworks and for electrical supply of transformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A B L E S - T H R E E C O R E

2XS≈2Y /

N2XS≈2Y

A2XS≈2Y /

NA2XS≈2Y

Uo/U - 6/10 kV, 12/20 kV, 18/30kVIEC 60502-2 / DIN VDE 0276-620

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 84: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 84/430

83

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen P≈ sheath

Construction data

2XSE2Y / N2XSE2Y, A2XSE2Y / NA2XSE2Y 6/10; 12/20; 18/30 kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion ofscreen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of Al

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

6/10 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120 rm /163x150rm /253x185 rm /253x240 rm /253x300 rm /25

12/20kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120 rm /163x150rm /253x185 rm /253x240 rm /25

18/30 kV3x50 rm /163x70 rm /163x95 rm /163x120 rm /16

3x150rm /25

3,43,43,43,43,43,43,43,43,4

5,55,55,55,55,55,55,55,5

8,08,08,08,0

8,0

2,52,52,72,82,93,03,23,43,5

2,82,93,03,13,23,43,53,7

3,33,43,53,7

3,8

161616161625252525

1616161616252525

16161616

25

46,448,853,057,160,364,268,574,379,6

56,759,363,367,470,674,778,884,5

71,775,879,883,3

87,1

101013631968273234404245531169818661

10101363196827323440424553116981

1363196827323440

4245

2849334842085229610872878632

1069012766

3714425951536226716284399830

11998

5505648076518665

10019

298404584809

10231257157920712589

298404584809

1023125715792071

404584809

1023

1257

217424372894340238124449508660276999

30383349383943994866560162847334

4596516758246369

7181

2XSE2Y, N2XSE2Y A2XS≈2Y, NA2XSE2Y

E L K A B E L

Page 85: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 85/430

Cable constructionConstruction According to IEC 60502

and DIN VDE 0276-620

Conductor —u and Al stranded compacted,according to IEC 60228 class 2and VDE 0295 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resistingelement Layer of semi-conductive water

absorbing tapes - discret

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm

Water resisting

element Layer of semi-conductive waterabsorbing tapes

Cable assembly Three insulated and screenedphases with longitudinal water-blocking element are twisted inthree core cable

Inner sheatth Filling and inner sheath-PE - LDPE

Sheath PE compound - HDPE

Color Black

Technical data

84

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking elements, aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequen-cy 50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medi-um industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A B L E S - T H R E E C O R E

Uo/U - 6/10 kV, 12/20 kV, 18/30kVIEC 60502-2 / DIN VDE 0276-620

2XS≈(F )2Y/

(N)2XS≈(F )2Y

A2XS≈(F )2Y/

(N)A2XS≈(F )2Y

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 86: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 86/430

85

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen with WB element PE sheath

Construction data

2XSE(F)2Y / (N)2XSE(F)2Y, A2XSE(F)2Y / (N)A2XSE(F)2Y 6/10; 12/20; 18/30 kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion ofscreen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of Al

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

6/10 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120 rm /163x150rm /253x185 rm /253x240 rm /25

12/20kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120 rm /163x150rm /253x185 rm /253x240 rm /25

18/30 kV3x50 rm /163x70 rm /163x95 rm /163x120 rm /163x150rm /25

3,43,43,43,43,43,43,43,4

5,55,55,55,55,55,55,55,5

8,08,08,08,08,0

2,52,62,72,93.03,13,23,4

2,82,93,03,13,23,43,53,7

3,33,43,53,73,8

1616161616252525

1616161616252525

1616161625

48.551.055.559.062.565.570.575.5

58.060.064.568.571.575.079.085.0

72.076.080.083,587,0

10101360196527303440424553106980

10101360196527303440424553106980

13601965273034404245

2715321540955125604571108740

10555

3160367745505570647575009150

10950

51246100712081109185

295405585805

1020125515752070

295405585805

1020125515752070

405585805

10201255

20052260271532203625444551956065

24452750317036504060455051006020

37104295516061207100

2XSE(F)2Y, (N)2XSE(F)2Y A2XS≈(F)2Y, (N)A2XSE(F)2Y

E L K A B E L

Page 87: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 87/430

Cable constructionConstruction According to IEC 60502

and DIN VDE 0276-620

Conductor —u and Al stranded compacted,according to IEC 60228 class 2and VDE 0295 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapes - discret

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm

Water resisting Layer of semi-conductive waterelement absorbing tapes

Cable assembly Three insulated and screenedphases with longitudinal water-blocking element are twisted inthree core cableFilling - filiers with water-blockingelement

Inner sheath Layer of semi-conductive waterabsorbing tapes

Radialprotection frommoisture ingress Al foil with copolymer layer

Sheath PE compound - HDPE

Color Black

Technical data

86

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal and radial water-blocking ele-ments, are designed for transfer and distribution of electrical power with nominal voltage Uo/U 6/10; 12/20 kV and fre-quency 50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small andmedium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A B L E S - T H R E E C O R E

2XS≈(FL )2Y/

(N)2XS≈(FL )2Y

A2XS≈(FL )2Y/

(N)A2XS≈(FL )2Y

Uo/U - 6/10 kV, 12/20 kVIEC 60502-2 / DIN VDE 0276-620

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 88: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 88/430

87

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu or Al conductors XLPE insulation Cu screen with WB element Al foil PE sheath

Construction data

2XSE(FL)2Y / (N)2XSE(FL)2Y, A2XSE(FL)2Y / (N)A2XSE(FL)2Y 6/10; 12/20kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion ofscreen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of Al

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

6/10 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120 rm /163x150rm /253x185 rm /253x240 rm /25

12/20kV3x70 rm /163x95 rm /163x120 rm /163x150rm /253x185 rm /253x240 rm /25

3,43,43,43,43,43,43,43,4

5,55,55,55,55,55,5

2,62,72,82,93.03,23,33,4

3,03,23,33,43,53,7

1616161616252525

161616252525

49.452.056.559.863.167.670.275.5

64.568.371,674,878,884.3

10101363196827303440424553106980

196527303440424553106980

2997350843795210605075088300

10363

42705280639571908540

10600

298404584805

1020125515752070

585810

1020125515752070

23212597306532853630407045555453

289033653985419548105670

2XSE(FL)2Y, (N)2XSE(FL)2Y A2XS≈(FL)2Y, (N)A2XSE(FL)2Y

E L K A B E L

Page 89: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 89/430

Cable constructionConstruction According to IEC 60502

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compoundOuter semi- semi-conductive XLPE compoundconductive layer and semi-conductive tape or

extruded semi-conductive XLPEcompound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Separating layer Layer of plastic tape

Sheath PVC compoundtype ST2 according to IEC 60502

Color red

Technical data

88

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 3.6/6kV; 8.7/15kV Ë 20/35 kV and frequency 50 Hz in urban and districtelectrical networks and for electrical supply of transformer's substations, small and medium industrial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

2 X S Y

A 2 X S Y

Uo/U - 3.6/6 kV, 8.7/15 kV, 20/35 kVIEC 60502-2

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kVHighest system voltage

Uo/U, no more than6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 90: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 90/430

89

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PVC sheath

Construction data 2XSY, A2XSY 3.6/6; 8.7/15; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross-

section ofscreen

Cablediameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

3,6/6 kV1x35rm /161x50rm /161x70rm /161x95rm /161x120rm /161x150rm /161x185rm /161x240rm /161x150rm /251x185rm /251x240rm /251x300rm /251x400rm /351x500rm /35

8,7/15 kV1x35rm /161x50rm /161x70rm /161x95rm /161x120rm /161x150rm /161x185rm /161x240rm /161x150rm /251x185rm /25

1x240rm /251x300rm /251x400rm /351x500rm /35

20/35 kV1x50rm /161x70rm /161x95rm /161x120rm /161x150rm /251x185rm /251x240rm /251x300rm /251x400rm /35

1x500rm /35

2,52,52,52,52,52,52,52,62,52,52,62,83,03,2

4,54,54,54,54,54,54,54,54,54,5

4,54,54,54,5

8,88,88,88,88,88,88,88,88,8

8,8

1,81,81,81,81,81,91,92,01,91,92,02,12,22,4

1,81,81,81,92,02,02,12,22,02,1

2,22,22,32,5

2,12,12,22,32,32,42,52,52,6

2,8

1616161616

16*16*16*252525253535

1616161616

16*16*16*2525

25253535

161616162525252535

35

21,022,123,825,526,928,630,333,128,630,333,136,039,943,9

25,026,127,829,731,332,834,737,332,834,7

37,339,6

43,0646,66

35,337,038,940,542,043,946,548,852,3

55,9

493604793

10331255150718422365159619302454298038364807

493604793

1033125515071842236515961930

2454298038364807

604793

1033125515961930245429803836

4807

804939

116614431696199623682969208024523053367046355750

942108313201619189421922590319922762674

3283387748365943

151617762103240128033229387445015503

6662

94127183254321394495649394495649812

10431374

94127183254321394495649394495

649812

10431374

127183254321394495649812

1043

1374

176176176176176176176176265265265265363363

176176176176176176176176265265

265265363363

176176176176265265265265363

363

581638732840938

105911981430114312821514176622062611

719782886

1016113612551419166013391503

1743197324072803

121513421500164318672058233525973074

3523

2XSY A2XSY

E L K A B E L

Page 91: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 91/430

Cable constructionConstruction According to IEC 60502

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- semi-conductive XLPE compound

conductive layer and semi-conductive tape orextruded semi-conductive XLPEcompound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Separating layer Layer of plastic tape

Sheath PE compoundtype ST7 according to IEC 60502

Color black

Technical data

90

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 3.6/6kV; 8.7/15kV Ë 20/35 kV and frequency 50 Hz in urban and district elec-trical networks and for electrical supply of transformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.

The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

2 X S 2 Y

A 2 X S 2 Y

Uo/U - 3.6/6 kV, 8.7/15 kV, 20/35 kVIEC 60502-2

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltage

Uo/U, no more than

6/10; 12/20 kV

12kV; 24kV kVTest voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S core

Cu cores - 50*n*S coren- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 92: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 92/430

91

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PE sheath

Construction data 2XS2Y, A2XS2Y 3.6/6; 7.5/15; 20/35 kV

Number ofconductors andnominal cross

section

Thic-kness ofinsulation

Thic-kness ofsheath

Nominalcross-

section ofscreen

Cablediame-

terapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

3,6/6 kV1x35rm /161x50rm /161x70rm /161x95rm /161x120rm /161x150rm /161x185rm /161x240rm /161x150rm /251x185rm /251x240rm /251x300rm /251x400rm /351x500rm /35

8,7/15kV1x35rm /161x50rm /161x70rm /161x95rm /161x120rm /161x150rm /161x185rm /161x240rm /161x150rm /251x185rm /25

1x240rm /251x300rm /251x400rm /351x500rm /35

20/35 kV1x50rm /161x70rm /161x95rm /161x120rm /161x150rm /251x185rm /251x240rm /251x300rm /251x400rm /35

1x500rm /35

2,52,52,52,52,52,52,52,62,52,52,62,83,03,2

4,54,54,54,54,54,54,54,54,54,5

4,54,54,54,5

8,88,88,88,88,88,88,88,88,8

8,8

1,81,81,81,81,81,91,92,01,91,92,02,12,22,4

1,81,81,81,92,02,02,12,22,02,1

2,22,22,32,5

2,12,12,22,32,32,42,52,52,6

2,8

1616161616

16*16*16*252525253535

1616161616

16*16*16*2525

25253535

161616162525252535

35

21,022,123,825,526,928,630,333,128,630,333,136,039,943,9

25,026,127,829,731,332,834,737,332,834,7

37,339,643,146,7

35,337,038,940,542,043,946,548,852,3

55,9

493604793

10331255150718422365159619302454298038364807

493604793

1033125515071842236515961930

2454298038364807

604793

1033125515961930245429803836

4807

754886

110813811630192222902879200623742963356745175609

881101912511543180921032491308821872575

3172376047035787

141616711987227626733087371943375321

6453

94127183254321394495649394495694812

10431374

94127183254321394495649394495

649812

10431374

127183254321394495649812

1043

1374

176176176176176176176176265265265265363363

176176176176176176176176265265

265265363363

176176176176265265265265363

363

531586674778872985

11201340106912031424166420882470

658718818940

105211661321154912501405

1633185622742649

111512371384151817371917218024332892

3315

2XS2Y A2XS2Y

E L K A B E L

Page 93: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 93/430

Cable constructionConstruction According to IEC 60502-2

Conductors —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- semi-conductive XLPEconductive layer compound

Water resisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Water resisting -I option - water absorbing insulat ingelement tape

-II option - water absorbing powderand a layer of plastic tape

Sheath PE compoundtype ST7 according to IEC 60502

Color Black

Technical data

92

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U U 3.6/6kV; 8.7/15kV Ë 20/35 kV and frequency 50 Hz in urban and districtelectrical networks and for electrical supply of transformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.

The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

2 X S ( F ) 2 Y

A 2 X S ( F ) 2 Y

Uo/U - 3.6/6 kV, 8.7/15 kV, 20/35 kVIEC 60502-2

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying N

max.where:

Al cores - 30*n*S core

Cu cores - 50*n*S coren- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 94: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 94/430

93

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PE sheath

Construction data2XS(F)2Y, A2XS(F)2Y 3.6/6; 8.7/15; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion ofscreen

Cablediameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

3,6/6 kV1x35 rm /161x50 rm /161x70 rm /161x95 rm /16

1x120 rm /161x150 rm /161x185rm /161x240rm /161x150rm /251x185rm /251x240rm /251x300rm /251x400rm /351x500rm /35

8,7/15kV1x35 rm /161x50 rm /161x70 rm /161x95 rm /16

1x120 rm /161x150 rm /161x185rm /161ı240rm /161x150rm /251x185rm /25

1x240rm /251x300rm /251x400rm /351x500rm /35

20/35 kV1x50 rm /161x70 rm /161x95 rm /16

1x120 rm /161x150rm /251x185rm /251x240rm /251x300rm /251x400rm /35

1x500rm /35

2,52,52,52,52,52,52,52,62,52,52,62,83,03,2

4,54,54,54,54,54,54,54,54,54,5

4,54,54,54,5

8,88,88,88,88,88,88,88,88,8

8,8

1,81,81,81,81,81,91,92,01,91,92,02,12,22,4

1,81,81,81,92,02,02,12,22,02,1

2,22,22,32,5

2,12,12,22,32,32,42,52,52,6

2,8

1616161616

16*16*16*252525253535

1616161616

16*16*16*2525

25253535

161616162525252535

35

22,223,325,026,728,329,831,734,529,831,734,537,441,345,1

26,227,329,230,932,534,235,938,534,235,9

38,541,044,547,9

36,538,440,141,743,445,147,750,253,7

57,1

493604793

10331255150718422365159619302454298038364807

493604793

1033125515071842236515961930

2454298038364807

604793

1033125515961930245429803836

4807

796930

115614321693198023612958206424453041365346105699

931107213171603187321802563316522642647

3249385448045883

148817582068235927733178381544535445

6569

94127183254321394495649394495649812

10431374

94127183254321394495649394495

649812

10431374

127183254321394495649812

1043

1374

176176176176176176176176265265265265363363

176176176176176176176176265265

265265363363

176176176176265265265265363

363

572629722829935

104411911418112812751502174921812560

708771883

1000111612441392162613281476

1710195023752744

118813251465160218362008227625503016

3430

2XS(F)2Y A2XS(F)2Y

E L K A B E L

Page 95: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 95/430

Cable constructionConstruction According to IEC 60502-2

Conductors —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Water resisting - water absorbing powderelement

Radialprotection from Al foil with copolymer layer moisture ingress

Sheath PE compoundtype ST7 according toIEC 60502-2

Color Black

Technical data

94

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution of

electrical power with nominal voltage Uo/U 3.6/6; 8.7/15; 20/35 kV and frequency 50 Hz in urban and district electricalnetworks and for electrical supply of transformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

2 X S ( F L ) 2 Y

A 2 X S ( F L ) 2 Y

Uo/U - 3.6/6 kV, 8.7/15, 20/35 kVIEC 60502-2

Conductor resistance at20∞C

According to IEC60228 class 2and VDE 0295 class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10; 12/20; 18/30 kV

Highest system voltageUo/U, no more than

6/10; 12/20; 18/30 kV12kV; 24kV; 36kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20; 18/30kV21kV; 42kV; 63kV67kV; 134kV; 201kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC / 2 pC15x D cable

no less than - 20∞—

Temperature of exploitationTests

-30 to 50∞—

according to IEC 60502-2 orDIN VDE 0276-620

Force of strain in laying Nmax.

Al cores - 30*n*S coreCu cores - 50*n*S core

where:

Tests - water penetration inthe region of metallicscreen

N is number of cores andS is cross section of cores inmm

IEC 60502-2 annex F

E L K A B E L

Page 96: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 96/430

95

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen Al foil PE sheath

Construction data 2XS(FL)2Y, A2XS(FL)2Y 3.6/6; 8.7/15; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion of

screen

Cablediameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

3,6/6 kV1x35 rm /161x50 rm /161x70 rm /161x95 rm /16

1x120 rm /161x150 rm /161x185rm /161x240rm /161x150rm /251x185rm /25

1x240rm /251x300rm /251x400rm /351x500rm /35

8,7/15kV1x35 rm /161x50 rm /161x70 rm /161x95 rm /16

1x120 rm /161x150 rm /161x185rm /161x240rm /161x150rm /251x185rm /251x240rm /25

1x300rm /251x400rm /351x500rm /35

20/35 kV1x50 rm /161x70 rm /161x95 rm /16

1x120 rm /161x150rm /251x185rm /251x240rm /251x300rm /251x400rm /351x500rm /35

2,52,52,52,52,52,52,52,62,52,52,62,83,03,2

4,54,54,54,54,54,54,54,54,54,54,5

4,54,54,5

8,88,88,88,88,88,88,88,88,88,8

1,81,81,81,81,81,91,92,01,91,92,02,12,22,4

1,81,81,81,92,02,02,12,22,02,12,2

2,22,32,5

2,12,12,22,32,32,42,52,52,62,8

1616161616

16*16*16*2525

25253535

1616161616

16*16*16*252525

253535

16161616252525253535

22,223,325,026,728,329,831,734,529,831,734,537,441,345,1

26,227,329,230,932,534,235,938,534,235,938,5

41,044,547,9

36,538,440,141,743,445,147,750,253,757,1

493604793

10331255150718422365159619302454298038364807

493604793

10331255150718422365159619302454

298038364807

604793

10331255159619302454298038364807

796930

115614321693198023612958206424453041365346105699

9311072131716031873218025633165226426473249

385448045883

1488175820682359277331783815445354456569

94127183254321394495649394495649812

10431374

94127183254321394495649394495649

81210431374

127183254321394495649812

10431374

176176176176176176176176265265265265363363

176176176176176176176176265265265

265363363

176176176176265265265265363363

572629722829935

10441191141811281275

1502174921812560

708771883

10001116124413921626132814761710195023752744

1188132514651602183620082276255030163430

2XS(FL)2Y A2XS(FL)2Y

E L K A B E L

Page 97: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 97/430

Cable constructionConstruction According to IEC 60502

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- semi-conductive XLPE compoundconductive layer and semi-conductive tape or

extruded semi-conductive XLPEcompound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm or Cu tapeslaid with overlap over each phase

Cable assembly Three insulated and screenesdphases are twisted with fillings andtape support

Inner sheath PVC compound

Sheath PVC compoundtype ST2 according to IEC 60502

Color red

Technical data

96

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 3.6/6kV; 8.7/15kV Ë 20/35 kV and frequency 50 Hz in urban and districtelectrical networks and for electrical supply of transformer's substations, small and medium industrial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A B L E S - T H R E E C O R E

2 X S ≈ Y

A 2 X S ≈ Y

Uo/U - 3.6/6 kV, 8.7/15 kV, 20/35 kV

Conductor resistance at

20∞C According to BDS904

(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV

12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV

15kV; 30kV kV

48kV; 96kV kV

Level of partial discharge

at 2*UoBending radius, min

Temperature of laying

max. 5 pC

15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 98: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 98/430

97

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen PVC sheath

Construction data

2XSEY, A2XSEY 3.6/6; 8.7/15; 20/35 kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion of

screen

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.

Mass of

Alapprox.

Mass of

cableapprox.

N x mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

3,6/6 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /253x185rm /253x240rm /253x300rm /25

8,7/15 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /253x185rm /253x240rm /253x300rm /25

20/35 kV3x50 rm /163x70 rm /163x95 rm /16

3x120rm /163x150rm /25

2,52,52,52,52,52,52,52,62,8

4,54,54,54,54,54,54,54,54,5

8,88,88,8

8,88,8

2,52,52,52,72,82,93,03,23,4

2,62,72,83,03,13,23,43,53,7

3,43,53,73,83,9

161616161625252525

161616161625252525

161616

1625

46,248,853,057,160,364,268,574,379,6

56,559,363,367,270,674,778,684,379,6

75,679,683,7

87,191,0

101013631968273234404245531169818661

101013631968273234404245531169818661

136319682732

34404245

2609307939044914578469438268

1033212497

3365388347605844675179789386

1150213631

607770838284

934310724

298404584809

10231257157920712589

298404584809

10231257157920712589

404584809

10231257

193321682590308734884105472256686729

268929723446401744565140584068387863

516657696456

70547885

2XSEY A2XSEY

E L K A B E L

Page 99: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 99/430

Cable constructionConstruction According to IEC 60502

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- semi-conductive XLPE compoundconductive layer and semi-conductive tape orextruded semi-conductive XLPEcompound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm or Cu tapeslaid with overlap over each phase

Cable assembly Three insulated and screenesdphases are twisted with fillings andtape support

Inner sheath PVC compound

Sheath P≈ compoundtype ST7 according to IEC 60502

Color Black

Technical data

98

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 3.6/6kV; 8.7/15kV Ë 20/35 kV and frequency 50 Hz in urban and districtelectrical networks and for electrical supply of transformer's substations, small and medium industrial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A B L E S - T H R E E C O R E

2 X S ≈ 2 Y

A 2 X S ≈ 2 Y

Uo/U - 3.6/6 kV, 8.7/15 kV, 20/35 kVIEC 60502-2

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 100: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 100/430

99

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen P≈ sheath

Construction data

2XSE2Y, A2XSE2Y 3.6/6; 8.7/15; 20/35 kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion of

screen

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.

Mass of

Alapprox.

Mass of

cableapprox.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

3,6/6 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120 rm /163x150rm /253x185 rm /253x240 rm /253x300 rm /25

8,7/15 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120 rm /163x150rm /253x185 rm /253x240 rm /253x300 rm /25

20/35 kV3x50 rm /163x70 rm /163x95 rm /16

3x120rm /163x150rm /25

2,52,52,52,52,52,52,52,62,8

4,54,54,54,54,54,54,54,54,5

8,88,88,8

8,88,8

2,52,52,52,72,82,93,03,23,4

2,62,72,83,03,13,23,43,53,7

3,43,53,7

3,83,9

161616161625252525

161616161625252525

161616

1625

46,248,853,057,160,364,268,574,379,6

56,559,363,367,270,674,778,684,379,6

75,679,683,7

87,191,0

101013631968273234404245531169818661

101013631968273234404245531169818661

136319682732

34404245

2552301938384837569968498165

1021312361

3289380346725743664278589252

1135413464

594869438129

917710546

298404584809

10231257157920712589

298404584809

10231257157920712589

404584809

10231257

187621082524301034044012461955496593

261328923358391643475020570666907697

503856296301

68887708

2XSE2Y A2XSE2Y

E L K A B E L

Page 101: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 101/430

Cable constructionConstruction According to IEC 60502

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapes - discret

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm

Water resisting Layer of semi-conductive waterelement absorbing tapes

Cable assembly Three insulated and screenedphases with longitudinal water-blocking element are twisted inthree core cable

Inner sheath Filling and inner sheath-PE - LDPE

Sheath PE compound - HDPE

Color Black

Technical data

100

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking elements aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 3.6/6kV; 8.7/15kV and frequency

50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and mediumindustrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A B L E S - T H R E E C O R E

2 X S ≈ ( F ) 2 Y

A 2 X S ≈ ( F ) 2 Y

Uo/U - 3.6/6 kV, 8.7/15kVIEC 60502-2

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 102: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 102/430

101

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen with WB element PE sheath

Construction data

2XSE(F)2Y, A2XSE(F)2Y 3.6/6; 8.7/15kV

Number of conductors

and nominal cross sec-tion

Thickness

of insula-tion

Thickness

ofsheath

Nominalcross sec-

tion ofscreen

Cable diameterapprox.

Mass ofCuapprox.

Mass ofcable

approx.Mass of Alapprox.

Mass ofcableapprox.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

3,6/6 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120 rm /163x150rm /253x185 rm /253x240 rm /25

8,7/15 kV3x120rm / 503x240 rm /50

2,52,52,52,52,52,52,52,6

4.54.5

2,52,52,62,72,82,93,13,3

3.13,6

1616161616252525

5050

44.246.951.054.968.261.465.371.8

6982.5

10101360196527303440424553106980

34406980

2440295037804785568567258035

10165

640010765

295405585805

1020125515752070

10202070

17301970240028653265374043055255

39835850

2XSE(F)2Y A2XSE(F)2Y

E L K A B E L

Page 103: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 103/430

Cable constructionConstruction According to IEC 60502

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapes - discret

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm

Water resisting Layer of semi-conductive waterelement absorbing tapes

Cable assembly Three insulated and screenedphases with longitudinal water-blocking element are twisted inthree core cableFilling - filiers with water-blockingelement

Inner sheath Layer of semi-conductive waterabsorbing tapes

Radialprotection from Al foil with copolymer layer moisture ingress

Sheath PE compound - HDPE

Color Black

Technical data

102

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal and radial water-blocking ele-ments, are designed for transfer and distribution of electrical power with nominal voltage Uo/U20/35 kV and frequency50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medium

industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A B L E S - T H R E E C O R E

2 X S ≈ ( F L ) 2 Y

A 2 X S ≈ ( F L ) 2 Y

Uo/U - 20/35 kVÔÓ ‡Ì‡Îӄˡ ̇ IEC 60502-2

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 20/35 kV

Highest system voltageUm, no more than

20/35 kV42 kV

Test voltage Uo/U AC ( ) - 5 minDC ( ) - 15 min

20/35 kV70 kV224 kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than -5∞—

Temperature ofexploitation

TestsForce of strain in laying

N max. where:

-30 to 500—according to IEC 60502 Al cores - 30*n*S coreCu cores - 50*n*S coren- number of cores and-S-cross-section in mm

E L K A B E L

Page 104: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 104/430

103

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu or Al conductors XLPE insulation Cu screen with WB element Al foil PE sheath

Construction data

2XSE(FL)2Y, A2XSE(FL)2Y 20/35 kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion ofscreen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of

Alapprox.

Mass of

cableapprox.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

20/35 kV3x70 rm /253x95 rm /253x120 rm /253x150rm /253x185 rm /353x185 rm /503x240 rm /25

8.88.88.88.88.88.88.8

3.53.73.83.94.04.04.2

25252525355025

49.783.687.290.194.094.079,6

1965273034404245531053106980

5665673075308775

101951033412285

585810

10251255157515752070

4285481052955785646565957375

2XSE(FL)2Y A2XSE(FL)2Y

E L K A B E L

Page 105: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 105/430

Cable constructionConstruction according to IEC 60502 -2

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-

conductive layer semi-conductive XLPE compound

Metal screen -I option - Cu tapes laid with overover each phase lap over each phaseMetal screen -II option - Cu wires laid concen

trically

Cable assembly Three insulated and screenedphases are twisted with fillingsand tape support

Inner sheatth PVC compound

Armour two steel tapesor two steel galvanized tapes

Sheath PVC compoundtype ST2 according to IEC 60502

Color red

Technical data

104

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequency 50 Hz in urban and district electricalnetworks and for electrical supply of transformer's substations, small and medium industrial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T

A G E P O W E R C A B L E S - T H R E E C O R E

2 X S E Y B Y

A 2 X S E Y B Y

Uo/U - 6/10 kV, 12/20 kV, 18/30kVIEC 60502-2

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U:6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 106: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 106/430

105

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen Armour st. tapes PVC sheath

Construction data

2XSEYBY, A2XSEYBY 6.10; 12/20; 18/30 kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion of

screen

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.

Mass of

Alapprox..

Mass of

cableapprox.

N x mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

6/10 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /253x185rm /253x240rm /253x300rm /25

12/20 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /253x185rm /253x240rm /25

18/30 kV3x50 rm /163x70 rm /163x95 rm /163x120rm /16

3x150rm /25

3,43,43,43,43,43,43,43,43,4

5,55,55,55,55,55,55,55,5

8,08,08,08,0

8,0

2,52,62,72,93,03,13,23,43,7

2,92,93,13,23,33,43,63,8

3,33,53,73,8

3,9

161616161625252525

1616161616252525

16161616

25

48,451,055,059,362,566,470,576,383,2

58,761,365,569,472,876,782,087,7

73,778,083,486,7

90,5

101013631968273234404245531169818661

10101363196827323440424553116981

1363196827323440

4245

3639420351176239717884339831

1200115023

471752866281743384309756

1206514364

676578529914

10996

12462

298404584809

10231257157920712589

298404584809

1023125715792071

404584809

1023

1257

296332923803441248825595628573379255

40414376496756066134691885199700

5854653880868701

9623

2XSEYBY A2XSEYBY

E L K A B E L

Page 107: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 107/430

Cable constructionConstruction according to IEC 60502 -2

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Metal screen -I option - Cu tapes laid withover each phase overlap over each phaseMetal screen -II option - Cu wires laid concen

trically

Cable assembly Three insulated and screenedphases are twisted with fillingsand tape support

Inner sheatth PVC compound

Armour two steel tapesor two steel galvanized tapes

Sheath PE compoundtype ST7 according to IEC 60502

Color Black

Technical data

106

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U U 6/10kV; 12/20kV Ë 18/30 kV and frequency 50 Hz in urban and districtelectrical networks and for electrical supply of transformer's substations, small and medium industrial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T

A G E P O W E R C A B L E S - T H R E E C O R E

2 X S E Y B 2 Y

A 2 X S E Y B 2 Y

Uo/U - 6/10 kV, 12/20 kV, 18/30kVIEC 60502-2

Conductor resistance at

20∞C

According to BDS904

(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltage

Uo/U, no more than

6/10; 12/20 kV

12kV; 24kV kV

Test voltage Uo/U

AC (≈) - 5 min

DC (=) - 15 min

6/10; 12/20 kV

15kV; 30kV kV

48kV; 96kV kV

Level of partial discharge

at 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC

15x D cable

no less than - 20∞—

Temperature of

exploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 108: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 108/430

107

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen Armour st. tapes PE sheath

Construction data

2XSEYB2Y, A2XSEYB2Y 6/10; 12/20; 18/30 kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion of

screen

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.

Mass of

Alapprox.

Mass of

cableapprox.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

6/10 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /253x185rm /253x240rm /253x300rm /25

12/20 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120 rm /163x150rm /253x185 rm /253x240 rm /25

18/30 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /16

3x120 rm /163x150rm /253x185 rm /25

3,43,43,43,43,43,43,43,43,4

5.55.55.55.55.55.55.55.5

8.08.08.08.0

8.08.08.0

2,52,62,72,93,03,13,23,43,7

2.82.93.03,23,33,43,53,7

3.23.33.43,63,73,84.0

161616161625252525

1616161616252525

16161616

162525

48,451,055,059,362,566,470,576,383,2

57.260.064.068.071.575.080.085.5

69.572.576.180.2

83.587.092.3

101013631968273234404245531169818661

10101363196827323440424553116981

1010136319682732

344042455311

3579413750436153708583309718

1187114868

414947335668679278008916

1112313404

5583622072268424

94971067213075

298404584809

10231257157920712589

298404584809

1023125715792071

298404584809

102312571579

290332263729432747825492617272079101

34373773428448695384592873918494

4871526158426501

708076849343

2XSEYB2Y A2XSEYB2Y

E L K A B E L

Page 109: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 109/430

Cable constructionConstruction according to IEC 60502 -2

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapes - discret

Metal screenover each phase Cu wires concentrically laid and one

contact of Cu tape with thicknessof 0.1mm

Water resisting Layer of semi-conductive waterelement absorbing tapes

Cable assembly Three insulated and screenedphases with longitudinal water-blocking element are twisted in

three core cable

Inner sheatth Filling and inner sheath-PE - LDPE/ bedding /

Armour two steel tapesor two steel galvanized tapes

Sheath For type 2Y- PE compound -HDPEFor type Y- PVC compoundtype ST2 according to IEC 60502

Color For type 2Y - blackFor type Y - red

Technical data

108

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking elements ,aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 6/10; 12/20; 12/20kV and frequency50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medium

industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T

A G E P O W E R C A B L E S - T H R E E C O R E

2 X S E ( F ) 2 Y B 2 Y /

2 X S E ( F ) 2 Y B Y

A 2 X S E ( F ) 2 Y B 2 Y /

A 2 X S E ( F ) 2 Y B Y

Uo/U - 6/10, 12/20 kVIEC 60502-2

Conductor resistance at

20∞C

According to BDS904

(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltage

Uo/U, no more than

6/10; 12/20 kV

12kV; 24kV kV

Test voltage Uo/U

AC (≈) - 5 min

DC (=) - 15 min

6/10; 12/20 kV

15kV; 30kV kV

48kV; 96kV kV

Level of partial discharge

at 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC

15x D cable

no less than - 20∞—

Temperature of

exploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 110: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 110/430

109

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen Armour St. tapes PE orPVC sheat

Construction data

2XSE(F)2YB2Y, A2XSE(F)2YB2Y 6/10; 12/20kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion of

screen

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.

Mass of

Alapprox.

Mass of

cableapprox.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

6/10 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /253x150rm /253x185rm /253x240rm /25

12/20 kV

3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /253x150rm /253x185rm /253x240rm /25

6/10 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /25

3x150rm /253x185rm /253x240rm /25

12/20 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /253x150rm /253x185rm /253x240rm /25

3,43,43,43,43,43,43,43,4

5.55.55.55.55.55.55.55.5

3,43,43,43,43,4

3,43,43,4

5.55.55.55.55.55.55.55.5

2.72.72,92,93,13,23,43,6

2.93.03.13.33.43.53,63,8

2.72.72,92,93,13,23,43,6

2.93.03.13.33.43.53,63,8

1616161625252525

1616161625252525

1616161625

252525

1616161625252525

53.055.559.562.567.070.574.580.0

61.063.567.071.075.078.082.087.5

53.055.559.562.567.0

70.574.580.0

61.063.567.071.075.078.082.087.5

10101360196527303440424553106980

10101360196527303440424553106980

10101360196527303440

424553106980

10101360196527303440424553106980

3635419050906100721583309780

11995

443050405975712581909330

1080513070

38504425535563807540

86851016012435

471053306300748085809750

1126013575

295405585805

1020125515752070

295405585805

1020125515752070

295405585805

1020

125515752070

295405585805

1020125515752070

29203240371041754800534060407085

37204085459551955770634070708160

31353470397544555120

569064257525

39954375492055556160676075258670

2XSE(F)2YB2Y A2XSE(F)2YB2Y

E L K A B E L

Page 111: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 111/430

Technical data

110

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 3.6/6kV; 8.7/15kV Ë 20/35 kV and frequency 50 Hz in urban and districtelectrical networks and for electrical supply of transformer's substations, small and medium industrial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T

A G E P O W E R C A B L E S - T H R E E C O R E

2 X S E Y B YA 2 X S E Y B Y

Uo/U - 3.6/6 kV, 8.7/15 kV, 20/35 kVIEC 60502-2

Cable constructionConstruction according to IEC 60502 -2

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Metal screen -I option - Cu tapesover each phase laid with overlap over each phaseMetal screen -II option - Cu wires laid concen

trically

Cable assembly Three insulated and screenedphases are twisted with fillingsand tape support

Inner sheatth PVC compound

Armour two steel tapesor two steel galvanized tapes

Sheath PVC compoundtype ST2 according to IEC 60502

Color red

Conductor resistance at

20∞C

According to BDS904

(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U

AC (≈) - 5 min

DC (=) - 15 min

6/10; 12/20 kV

15kV; 30kV kV

48kV; 96kV kV

Level of partial discharge

at 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC

15x D cable

no less than - 20∞—

Temperature of

exploitation -30 to 50∞—

Tests according to IEC 60502-2 orDIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 112: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 112/430

111

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen Armour st. tapes PVC sheath

Construction data

2XSEYBY, A2XSEYBY 3.6/6; 8.7/15; 20/35 kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion ofscreen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of

Alapprox.

Mass of

cableapprox.

N x mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

3,6/6 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /253x185rm /253x240rm /253x300rm /25

8,7/15 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /253x185rm /253x240rm /25

20/35 kV3x50 rm /163x70 rm /163x95 rm /163x120rm /16

3x150rm /25

2,52,52,52,52,52,52,52,62,8

4,54,54,54,54,54,54,54,5

8,88,88,88,8

8,8

2,52,52,62,72,83,03,13,33,5

2,72,82,93,13,23,33,43,7

3,53,63,83,9

4,0

161616161625252525

1616161616252525

16161616

25

44,346,750,854,858,362,166,272,478,8

54,056,560,664,968,172,076,083,2

77,881,887,190,5

94,4

101013631968273234404245531169818661

10101363196827323440424553116981

1363196827323440

4245

3270378246965749671679209314

1148113751

421047675714686778279121

1056213620

73168388

1047111626

13106

298404584809

10231257157920712589

298404584809

1023125715792071

404584809

1023

1257

259428713382

3921844205081576868177983

35343856440050405532628370168956

6405707386449331

10268

2XSEYBY A2XSEYBY

E L K A B E L

Page 113: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 113/430

Technical data

112

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 3.6/6kV; 8.7/15kV Ë 20/35 kV and frequency 50 Hz in urban and districtelectrical networks and for electrical supply of transformer's substations, small and medium industrial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T

A G E P O W E R C A B L E S - T H R E E C O R E

2 X S E Y B 2 YA 2 X S E Y B 2 Y

Uo/U - 3.6/6 kV, 8.7/15 kV, 20/35 kVIEC 60502-2

Cable constructionConstruction according to IEC 60502 -2

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Metal screen -I option - Cu tapesover each phase laid with overlap over each phaseMetal screen -II option - Cu wires laid concen

trically

Cable assembly Three insulated and screenedphases are twisted with fillingsand tape support

Inner sheatth PVC compound

Armour two steel tapesor two steel galvanized tapes

Sheath PE compound

type ST7 according to IEC 60502Color Black

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 114: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 114/430

113

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen Armour st. tapes PE sheath

Construction data

2’SEYB2Y, A2XSEYB2Y 3.6/6; 8.7/15; 20/35 kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion ofscreen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of

Alapprox.

Mass of

cableapprox.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

3,6/6 kV3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /253x185rm /253x240rm /253x300rm /25

8,7/15 Kv3x35 rm /163x50 rm /163x70 rm /163x95 rm /163x120rm /163x150rm /253x185rm /253x240rm /25

20/30 kV3x50 rm /163x70 rm /163x95 rm /163x120rm /16

3x150rm /25

2,52,52,52,52,52,52,52,62,8

4,54,54,54,54,54,54,54,5

8,88,88,88,8

8,8

2,52,52,62,72,83,03,13,33,5

2,72,82,93,13,23,33,43,7

3,53,63,83,9

4,0

161616161625252525

1616161616252525

16161616

25

44,346,750,854,858,362,166,272,478,8

54,056,560,664,968,172,076,083,2

77,881,887,190,5

94,4

101013631968273234404245531169818661

10101363196827323440424553116981

1363196827323440

4245

3215372446305675663578279211

1136113612

413746885626676677189002

1043213465

71798240

1030411448

12916

298404584809

10231257157920712589

298404584809

1023125715792071

404584809

1023

1257

253928133316385443384987566566977845

34613777431249395423616468868802

6268692584789153

10078

2XSEYB2Y A2XSEYB2Y

E L K A B E L

Page 115: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 115/430

Technical data

114

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking elements ,aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 3.6/6; 8.7/15 kV and frequency 50Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medium

industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T

A G E P O W E R C A B L E S - T H R E E C O R E

2 X S E ( F ) 2 Y B 2 Y /

2 X S E ( F ) 2 Y B Y

A 2 X S E ( F ) 2 Y B 2 Y /

A 2 X S E ( F ) 2 Y B Y

Cable construction

Construction according to IEC 60502 -2

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapes - discret

Metal screen over Cu wires concentrically laid andeach phase contact of Cu tape with

thickness one of 0.1mm

Water resisting Layer of semi-conductive waterelement absorbing tapes

Cable assembly Three insulated and screenedphases with longitudinal water-

blocking element are twisted inthree core cable

Inner sheatth/ bedding / Filling and inner sheath-PE - LDPE

Armour two steel tapesor two steel galvanized tapes

Sheath For type 2Y- PE compound -HDPEFor type Y- PVC compoundtype ST2 according to IEC 60502

Color For type 2Y - blackFor type Y - red

Uo/U - 3.6/6, 8.7/15 kVIEC 60502-2

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Testsaccording to IEC 60502-2 or

DIN VDE 0276-620

Force of strain in laying Nmax.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section ofconductors in mm

E L K A B E L

Page 116: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 116/430

115

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen Armour St. tapes PE orPVC sheat

Construction data

2XSE(F)2YB2Y, A2XSE(F)2YB2Y 3.6/6; 8.7/15kV

Number of conductorsand nominal cross sec-

tion

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross sec-

tion of

screen

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.

Mass of

Alapprox.

Mass of

cableapprox.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

3.6/6 kV3x70 rm /163x95 rm /163x120rm /253x150rm /253x185rm /25

8.7/15 kV3x70 rm /163x95 rm /163x120rm /25

3x150rm /253x185rm /25

3.6/6 kV3x70 rm /163x95 rm /163x120rm /253x150rm /253x185rm /25

8.7/15 kV3x70 rm /163x95 rm /163x120rm /253x150rm /25

3x185rm /25

2.52.52.52.52.5

4.54.54.5

4.54.5

2.52.52.52.52.5

4.54.54.54.5

4.5

2.72.93.03.13.2

3.03.03.3

3.43,5

2.72.93.03.13.2

3.03.03.33.4

3,5

1616252525

161625

2525

1616252525

16162525

25

55.058.562.566.070.0

65.067.572.5

75.579.5

55.058.562.566.070.0

65.067.572.575.5

79.5

19652730344042455310

196527303440

42455310

19652730344042455310

1965273034404245

5310

46905705677078659280

561566107750

891510385

49205965705581759630

5920622081209310

10820

585805

102012551575

585805

1020

12551575

585805

102012551575

585805

10201255

1575

33103780435048755545

423546805335

59256650

35404040464051905895

4540499057006320

7085

2XSE(F)2YB2Y A2XSE(F)2YB2Y

E L K A B E L

Page 117: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 117/430

Technical data

116

Application

The cables are designed for transfer and distribution of electrical power wite nominal voltage Uo/U 12/20 kV and fre-

quency 50 Hz in urban and district electrical networks. The cables can be installed in air hanger on supporting elementincluded in the bundle of three phases.They are recommended in:- regions where is not allowed cutting of trees for openings of overhead lines;- in boggy terrains where digging of a ditch is difficult and expensive;- in coastal and highly polluted industrial areas in atmosphere as well as in ground;- in stony wooden areas;-in all cases when laying of cables in the ground and construction of overhead lines is hampered and effective over-head cabling can be proved.

A 2 X S ( F ) 2 Y TA 2 X S 2 Y T

Uo/U - 12/20 kVIEC 60502-2

Conductor resistance at

20∞C

According to IEC60228

class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 12/20 kV

Highest system voltage

Uo/U, no more than

12/20kV

24kV

Test voltage Uo/U

AC (≈) - 5 min

DC (=) - 15 min

12/20kV

42kV

134kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation -30 to 50∞—

Tests according to IEC 60502-2

Cable construction

Construction According to IEC 60502-2

Conductor Al stranded compacted, according

to IEC 60228 class 2Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Waterresisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Waterresisting -I option - water absorbing insuelement lating tape

-II option - water absorbing powderand a layer of plastic tape

Sheath PE compoundtype ST7 according to IEC 60502

Color black

Supporting St rope with insulationinsulated Strope Constructions twisted into a bundle

Cable lay up include:TRIPLEX - 3-phase and supporting insulated

St rope

M I D D L E

V O L T A G E P O W

E R C A B L E S F O

R O V E R H E A D L

I N E S

E L K A B E L

Page 118: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 118/430

Construction data A2XS2YT, A2XS(F)2YT 12/20 kV

Number of conductors andnominal cross section

Thickness ofinsulation

Thickness ofsheath

Nominalcross section

of screen

Diameter of bun-dle

approx.

Mass of Al

approx.

Mass of cableapprox.

N x mm2 mm mm mm2 mm kg/km kg/km

* Water blocking element is aveilable in cables type A2XS(F)2YT

3ı(1ı50rm/16)+50St3ı(1ı70rm/16)+50St

3ı(1ı120rm/16)+50St

5.55,55,5

2.52,52,5

161616

636976

390570990

328236244025

117

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Al conductors XLPE insulation Cu screen PE sheath Supporting St rope

E L K A B E L

Page 119: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 119/430

Technical data

118

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking elements ,aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 3.6/6; 8.7/15 kV and frequency 50Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medium

industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

Cu/XLPE/CTS/PVC/AWA/PVC

Al/XLPE/CTS/PVC/AWA/PVC

Cable construction

Construction According to BS 6622

Conductor —u or Al stranded compacted,according to BS 6360 (IEC60228class 2 )

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Metal screen Cu tapes laid with overlap

Separating layer PVC compound - type 9

Armour ¿l wires laid concentr ically

Sheath PVC compound - type 9 toBS 6755-4.2

Color black or red

Uo/U - 6.35/11 kV; 8.7/15kV;12.7/22 kV; 19/33 kV

BS 6622

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U:6.35/11;8.7/15; 12.7/22; 19/33

kV

Highest system voltageUo/U, no more than

12kV ; 17.5kV; 24 kV; 36 kV

Test voltage AC (≈) - 15 min

Level of partial dischargeat :

25.5 ÍV; 35kV; 51kV;76kV

12.5 kV; 17.5kV; 25.5kV;38kV

χı 10pC

Bending radius, minBending radius adjacent to

joints or terminations,min

Temperature of laying

15x D cable

12x D cableno less than 0∞—

Ambient temperatures - 30 to 50∞—

Force of strain in laying Nmax.

Al cores - 30*n*S coreCu cores - 50*n*S core

n-number of cores andS-cross section of cores inmm

E L K A B E L

Page 120: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 120/430

119

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu or Al cores XLPE insulation Cu screen PVC sheath Armour Al wires PVC sheath

Construction data

Cu/XLPE/CTS/PVC/AWA/PVC Al/XLPE/CTS/PVC/AWA/PVC

6.35/11 kV; 8.7/15 kV;12.7/22 kV; 19/33 kV

Number of conductorsand nominal crosssection

Thicknessofinsulation

Diameter

of Al wires -for armor

Thicknessof sheath

Cable diameterapprox. Mass of

Cuapprox.

Cable massapprox.

Mass of Al

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

6.35/11 kV1x50 rm1x70 rm1x95 rm1x120rm1x150rm1x185rm1x240rm1x300rm

1x400rm1x500rm

8,7/15 kV1x50 rm1x70 rm1x95 rm1x120rm1x150rm1x185rm1x240rm1x300rm1x400rm1x500rm

12.7/22 kV1x50 rm1x70 rm1x95 rm1x120rm1x150rm1x185rm1x240rm1x300rm1x400rm1x500rm

19 / 33 kV1x50 rm1x70 rm1x95 rm

1x120rm1x150rm1x185rm1x240rm1x300rm1x400rm1x500rm

3.43.43.43.43.43.43.43.4

3,43,4

4,54,54,54,54,54,54,54,54,54,5

5.55.55.55.55.55.55.55.55.55.5

8.08.08.08.08.08.08.08.08.08.0

1,61,61,61,62.02.02,02.0

2,02,5

1.62.02.02.02,02.02.02,02,52,5

1.62.02.02.02,02.02.02,52,52,5

2.02.02.0

2,02.02.52.52,52.52,5

1.81.91.92.02.12.12.22.2

2.42.5

1.91.92.02.12.12.22.32.32.52.6

2.02.02.12.12.22.22.32.42.52.6

2.22.22.3

2.32.42.52.52.62.72.8

27.429.230.932.534.936.639.241.4

44.649.2

29.832.234.135.737.139.041.843.848.251.6

32.034.436.337.739.341.043.647.250.253.8

38.239.841.743.246.047.950.352.956.560.1

425615855

10801330166521902715

34754445

425615855

1080133016652190271534754445

425615855

1080133016652190271534754445

425615855

1080133016652190271534754445

12651550185021602600300036604310

52456585

1405175021002415274031903855451056506830

1545190022552555290533404045488058507065

206023502720

3035356540454755548066057715

355435520605770895

10851280

15302080

3755515615695790915

1140128517002085

340550645730825955

1135147017452145

545620710795

102511651365156018202170

9701115126514151655184521402425

28353555

1110132015001655180020202360260532203760

1250147516601805198021852520301534404035

176519252125

2285264028903230359040954685

Cu/XLPE/CTS/PVC/AWA/PVC

Al/XLPE/CTS/PVC/ AWA/PVC

E L K A B E L

Page 121: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 121/430

Technical data

120

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking elements ,aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 3.6/6; 8.7/15 kV and frequency 50Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medium

industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

Cu/XLPE/CTS/PVC/SWA/PVCAl/XLPE/CTS/PVC/SWA/PVC

Cable construction

Construction According to BS 6622

Conductor —u or Al stranded compacted,according to BS 6360 (IEC 60228)class 2

Inner semi-conductive layer: semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Metal screen -I option - Cu tapes laid withover each phase overlap over each phase

-II option - Cu wires laid concentrically

Cable assembly Three insulated and screenedphases are twisted with fillingsand tape support

Separating layer PVC compound - type 9

Armour Galvanized steel wires, laidconcentrically

Sheath PVC compound - type 9 toBS 6755-4.2

Color black

Uo/U - 3.8/6.6 kV; 6.35/11 kV;8.7/15 kV;12.7/22 kV; 19/33 kV

BS 6622

Conductor resistance at

20∞C

According to

BS 6360 (IEC228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U:3.8/6.6; 6.35/11; 8.7/15;

12.7/22; 19/33

Highest system voltage

Uo/U, no more than

7.2; 12; 17.5;

24; 36

Test voltage

AC (≈) - 15 min

15; 25.5; 35;

51; 76ÍV

Level of partial dischargeat kV

7.5; 12.5; 17.5; 25.5;38 ÍV

max. 10pC

Bending radius, min 12x D cable

Bending radius adjacentto joints or terminations,

min10x D cable

Temperature of laying no less than 0∞—

Temperature of exploita-tion

-30 to 50∞—

Force of strain in laying Nmax.n-number of cores and

Al cores - 30*n*S coreCu cores - 50*n*S coreS-cross section of cores inmm

E L K A B E L

Page 122: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 122/430

121

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu or Al cores XLPE insulation Cu screen PVC sheath Armour Al wires PVC sheath

Construction data

Cu/XLPE/CTS/PVC/SWA/PVC Al/XLPE/CTS/PVC/SWA/PVC

3.8/6.6 kV; 6.35/11 kV; 8.7/15 kV;12.7/22 kV; 19/33 kV

Number of conductorsand nominal crosssection

Thicknessofinsulation

Diameterof

St wires -for armor

Thicknessof sheath

Cable diameterapprox. Mass of

Cuapprox.

Cable massapprox.

Mass of Al

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km

3.8/6.6 kV3x35 rm3x50 rm3x70 rm3x95 rm3x120rm3x150rm

6.35/11 kV

3x35 rm3x50 rm3x70 rm3x95 rm3x120rm

8,7/15 kV3x35 rm3x50 rm3x70 rm3x95 rm

12.7/22 kV3x50 rm

3x70 rm3x95 rm3x120rm3x150rm

19 / 33 kV3x50rm3x70 rm3x95 rm

2.52.52.52.52.52.5

3.43.43.43.43.4

4.54.54.54.5

5.5

5.55.55.55.5

8.08.08.0

2.02.52.52.52.52.5

2.52.52.52.52.5

2.52.52.52.5

2.52.52.5

3.153.15

3.153.153.15

2.32.52.62.72.82.9

2.52.62.72.83.0

2.72.82.93.0

2.9

3.03.23.33.4

3.43.53.6

44.047.751.455.759.162.5

49.552.456.060.163.7

54.057.361.065.0

62.1

66.070.274.878.4

75.879.583.5

101013601965273034404245

10101360196527303440

1010136019652730

13601965273034404245

136019652730

358048505825702579959010

47705390647074258415

5365592067707835

6355

726584001076511890

90209940

11095

295405585810

10201255

295405585810

1020

295405585810

405

58581010201255

405585810

286538904445510555756020

40554435509055055995

4650496553905915

54005885648083458900

803585609180

Cu/XLPE/CTS/PVC/SWA/PVC

Al/XLPE/CTS/PVC/SWA/PVC

E L K A B E L

Page 123: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 123/430

Technical data

122

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 6.35/11 and 19/33 kV and frequency 50 Hz in urban and district electricalnetworks and for electrical supply of transformer's substations, small and medium industrial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

C u / X L P E / C W S / P EA l / X L P E / C W S / P E

Cable construction

Construction According to BS 7870-4.10

Conductor —u and Al stranded compacted,according to IEC 60228 class 2and BS 6360

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Separating layer Layer of plastic tape

Sheath PE compound type MDPEaccording to BS 7870

Color For 11kV - RedFor 33kV - Black

Uo/U - 6.35/11 kV; 19/33 kVBS 7870-4.10

Conductor resistance at

20∞C

According to IEC60228

class 2 and BS 6360

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6.35/11kV 19/33kV

Highest system voltage

Uo/U, no more than12kV 36kV

Test voltage

AC (≈) - 15 min25.4kV 76kV

Level of partial discharge

at 2*Uo

Bending radius, min

Temperature of laying

max. 10 pC

15x D cable

no less than -5∞—

Temperature of

exploitation -30 to 50∞—

Tests according to BS 7870-4.10

Force of strain in laying N ,max.

Al cores - 30*n*S coreCu cores - 50*n*S core

where:n- number of cores and-S-cross-section of conduc-tors in mm

E L K A B E L

Page 124: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 124/430

123

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu or Al conductors XLPE insulation Cu screen PE sheath

E L K A B E L

Construction dataCu/XLPE/CWS/PE and Al/XLPE/CWS/PE 6.35/11; 19/33 kV

Number of conduc-tors and nominal

cross section

Thic-kness of

insulation

Thic-kness of

sheath

Nominalcross

section of

screen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of

Alapprox.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

1x240rm /351x300rm /351x400rm /351x500 rm /35

Al/XLPE/CWS/PE1x70rm /351x95rm /35

1x150rm /351x185rm /35

1x240rm/351x300rm /35

19/33 kV1x120rm /351x150rm /351x185rm /351x240rm /351x300rm /351x400rm /351x500rm /35

3,43,43,43,4

3,43,43,43,4

3.43,4

8.08.08.08.08.08.08.0

2.02,12.22,3

1.71.81.91.9

2.02.1

2,12,22,22,32,42,52,6

35353535

35353535

3535

35353535353535

36.238.641.144.5

2728.932

33.6

36.238.6

39.641.242.945.547.951.555.0

36.639.142.445.7

2729

32.234

36.639

41.143

44.847.550.053.356.5

2548307838354805

---

---

1443169320282548307838354805

3268386847175792

---

---

2400270031003725434552906410

190260405510

665830

330405510665830

10601410

363363363363

363363

363363363363363363363

999113414101511

17431983

1640177019452205246028804375

Cu/XLPE/CWS/PE Al/XLPE/CWS/PE

min max

6.35/11 kV

Cu/XLPE/CWS/PE

Page 125: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 125/430

Technical data

124

Application

The three single-core cables with insulation of cross-linked polyethylene (XLPE) factory bindled in TRIPLEX, aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 6.35/11 and 19/33 kV and frequen-cy 50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medi-

um industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

Cu/XLPE/CWS/PE - TR IPLEX

Al /XLPE/CWS/PE - TR IPLEX

Cable construction

Construction According to BS 7870-4.10

Conductor —u and Al stranded compacted,according to IEC 60228 class 2and BS 6360

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Separating layer Layer of plastic tape

Sheath PE compoundtype MDPE accordingto BS 7870

Factory bundled three single-core cablesin TRIPLEX factory bindled in TRIPLEX

Color For 11kV - RedFor 33kV - Black

Uo/U - 6.35/11 kV; 19/33 kVBS 7870-4.10

Conductor resistance at20∞C

According to IEC60228class 2 and BS 6360

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6.35/11kV 19/33kV

Highest system voltageUo/U, no more than

6.35/11; 19/33 kV12kV; 36kV

Test voltage AC (≈) - 15 min

6.35/11; 19/33kV25.4kV; 76kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 10 pC

15x D cable

no less than -5∞—

Temperature ofexploitation -30 to 50∞—

Tests according to BS 7870-4.10

Force of strain in laying N ,max.

Al cores - 30*n*S coreCu cores - 50*n*S core

where:n- number of cores and-S-cross-section of conduc-tors in mm

E L K A B E L

Page 126: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 126/430

125

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu or Al conductors XLPE insulation Cu screen PE sheath

E L K A B E L

Construction dataCu/XLPE/CWS/PE- TRIPLEX and Al/XLPE/CWS/PE- TRIPLEX 6.35/11; 19/33 kV

Number of conduc-tors and nominal

cross section

Thic-kness of

insulation

Thic-kness of

sheath

Nominalcross

section of

screen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of

Alapprox.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

3x(1x240rm /35)3x(1x300rm /35)

3x(1x70rm /35)3x(1x95rm /35)

3x(1x150rm /35)3x(1x185rm /35)3x(1x240rm/35)

3x(1x300rm /35)

19/33 kV

3x(1x120rm /35)3x(1x150rm /35)3x(1x185rm /35)

3,43,4

3,43,43,43,43.4

3,4

8.08.08.0

2.02,1

1.71.81.91.92.0

2.1

2,12,22,2

Cu/XLPE/CWS/PE Al/XLPE/CWS/PE

min max

6.35/11 kV

Cu/XLPE/CWS/PE - TRIPLEX

Al/XLPE/CWS/PE - TRIPLEX

Cu/XLPE/CWS/PE - TRIPLEX

Al/XLPE/CWS/PE - TRIPLEX

3535

3535353535

35

353535

78.183.3

58.062.469.172.478.2

83.2

39.641.292.7

79.184.5

58.563.070.273.480.0

84.2

41.143

96.7

76039181

-----

-

432950796084

950511277

-----

-

720081009300

--

570780

121515301995

2490

99012151530

--

10241024102410241024

1024

102410241024

--

28123165382242584922

5610

492053105835

Page 127: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 127/430

Technical data

126

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 6.35/11 and 19/33 kV and frequency 50 Hz in urban and district electricalnetworks and for electrical supply of transformer's substations, small and medium industrial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

Cu/XLPE/CWS/PE -wbAl /XLPE /CWS/PE -wb

Cable construction

Construction According to BS 7870-4.10

Conductor —u and Al stranded compacted,according to IEC 60228 class 2and BS 6360

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- semi-conductive XLPE compoundconductive layer

Water resisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Water resisting -I option - water absorbingelement insulating tape

-II option - water absorbingpowder and a layer of plastic tape

Sheath PE compoundtype MDPE accordingto BS 7870

Color For 11kV - RedFor 33kV - Black

Uo/U - 6.35/11 kV; 19/33 kVBS 7870 - 4.10

Conductor resistance at20∞C

According to IEC60228class 2 and BS 6360

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6.35/11kV 19/33kV

Highest system voltageUo/U, no more than

6.35/11; 19/33 kV12kV; 36kV

Test voltage AC (≈) - 15 min

6.35/11; 19/33kV25.4kV; 76kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 10 pC

15x D cable

no less than -5∞—

Temperature ofexploitation -30 to 50∞—

Tests according to BS 7870-4.10

Force of strain in laying N ,max.

Al cores - 30*n*S coreCu cores - 50*n*S core

where:n- number of cores and-S-cross-section of conduc-tors in mm

E L K A B E L

Page 128: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 128/430

127

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu or Al conductors XLPE insulation Cu screen PE sheath

E L K A B E L

Construction dataCu/XLPE/CWS/PE-wb and Al/XLPE/CWS/PE-wb 6.35/11; 19/33 kV

Number of conduc-tors and nominal

cross section

Thic-kness of

insulation

Thic-kness of

sheath

Nominalcross

section of

screen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of

Alapprox.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

1x240rm /351x300rm /351x400rm /35

1x500 rm /35

1x70rm /351x95rm /35

1x150rm /351x185rm /35

1x240rm/351x300rm /35

19/33 kV

1x120rm /351x150rm /351x185rm /351x240rm /351x300rm /351x400rm /351x500rm /35

Cu/XLPE/CWS/PE Al/XLPE/CWS/PE

min max

6.35/11 kV

Cu/XLPE/CWS/PE -wb

Al/XLPE/CWS/PE-wb

Cu/XLPE/CWS/PE -wb

Al/XLPE/CWS/PE -wb

----

363363363363

363363

363363363363363363363

----

1015116414401551

17932020

1664181019862236250129223418

3,43,43,43,4

3,43,43,43,4

3.43,4

8.08.08.08.08.08.08.0

2.02,12.22,3

1.71.81.91.9

2.02.1

2,12,22,22,32,42,52,6

35353535

35353535

3535

35353535353535

36.238.641.144.5

2728.932

33.6

36.238.6

39.641.242.945.547.951.555.0

36.639.142.445.7

2729

32.234

36.639

41.143

44.847.550.053.356.5

----

190260405510

665830

330405510665830

10601410

3298391047605820

---

---

2414273031303756439953346450

2548307838354805

---

---

1443169320282548307838354805

Page 129: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 129/430

Technical data

128

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking elements aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 6.35/11 and 19/33 kV and frequen-cy 50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medi-

um industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

CuwXLPE/CWS/PE -wbAlwXLPE/CWS/PE -wb

Cable construction

Construction According to BS 7870-4.10

Conductor with —u and Al stranded compacted, water resisting element according to IEC 60228

class 2and BS 6360 with water powder absorbing

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Water resisting -I option - water absorbingelement insulating tape

Sheath PE compoundtype MDPE accordingto BS 7870

Color For 11kV - RedFor 33kV - Black

Uo/U - 6.35/11 kV; 19/33 kVBS 7870 - 4.10

Conductor resistance at20∞C

According to IEC60228class 2 and BS 6360

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6.35/11kV 19/33kV

Highest system voltageUo/U, no more than

6.35/11; 19/33 kV12kV; 36kV

Test voltage AC (≈) - 15 min

6.35/11; 19/33kV25.4kV; 76kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 10 pC

15x D cable

no less than -5∞—

Temperature ofexploitation -30 to 50∞—

Tests according to BS 7870-4.10

Force of strain in laying N ,max.

Al cores - 30*n*S coreCu cores - 50*n*S core

where:n- number of cores and-S-cross-section of conduc-tors in mm

E L K A B E L

Page 130: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 130/430

129

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu or Al conductors XLPE insulation Cu screen PE sheath

E L K A B E L

Construction dataCuwXLPE/CWS/PE-wb and Alw/XLPE/CWS/PE-wb 6.35/11; 19/33 kV

Number of conduc-tors and nominal

cross section

Thic-kness of

insulation

Thic-kness of

sheath

Nominalcross

section of

screen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of

Alapprox.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

1x240rm /351x300rm /351x400rm /35

1x500 rm /35

1x70rm /351x95rm /35

1x150rm /351x185rm /35

1x240rm/351x300rm /35

19/33 kV

1x120rm /351x150rm /351x185rm /351x240rm /351x300rm /351x400rm /351x500rm /35

Cu/XLPE/CWS/PE Al/XLPE/CWS/PE

min max

6.35/11 kV

Cuw/XLPE/CWS/PE -wb

Alw/XLPE/CWS/PE-wb

Cuw/XLPE/CWS/PE -wb

Alw/XLPE/CWS/PE -wb

363363363363

363363

363363363363363363363

1020117014451560

18052035

1668181519902247251529453444

3,43,43,43,4

3,43,43,43,4

3.43,4

8.08.08.08.08.08.08.0

2.02,12.22,3

1.71.81.91.9

2.02.1

2,12,22,22,32,42,52,6

35353535

35353535

3535

35353535353535

36.238.641.144.5

2728.932

33.6

36.238.6

39.641.242.945.547.951.555.0

36.639.142.445.7

2729

32.234

36.639

41.143

44.847.550.053.356.5

----

190260405510

665830

330405510665830

10601410

3310392547805845

---

---

2417273531413767439953676476

2548307838354805

---

---

1443169320282548307838354805

Page 131: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 131/430

Technical data

130

Application

The three-core cables with insulation of polyvinylchloride (PVC) - armored type are designed for transfer and distribu-tion of electrical power in networks with voltage of 6000 V and in industrial plants. For cable EVAVB the sheath is PVCcompound and for cable EVAVB - F2 - PVC compound flame retardant .

The cables are for fixed assembly in lines with unlimited difference levels, for underground laying, in cable ducts, con-duits, trenches, pipes, shafts over shelves and grills directly underground in ditch.

M I D D L E V O L T A

G E P O W E R C A

B L E S

E V A V BE V A V B - F 2

Uo/U 3.6/6 kVNBN C 33-121 and modifications

No 1 and 2

Cable construction

Construction According to NBN C 33-121

Conductor —u stranded compacted circularand sector, according to NBN C33-121 (IEC60228 class 2)

Insulation PVC compound

Cable assembly three insulated phases are twisted

with fillings and tape supportInner sheath polymer material

Armour-screen of the two steel tapes underneaththe tapes for improving thepermeability are laid Cu wires

Outer sheath for EVAVB -PVC compoundfor EVAVB - F2 - PVC compoundflame retardant

Color black

Conductor resistance at

20∞CNBN C 33-121 (IEC60228)

class 2

Operating temperature 70∞— continuous operation

Short circuit temperature 160∞— /5 s max./

Nominal voltage Uo/U: 3.6/6kV

Maximum voltage nomore than

Insulated volumeresistance

6600V

at 20∞—-min5.5*1013Ωcm

at 60∞—-min1*1011Ωcm

Test voltage AC (≈) - 20 min

Between cores and between

cores and screen (armor) -

13kV

Bending radius, min

Temperature of laying

20x D cable

no less than 0∞—

Temperature ofexploitation

-15 to 70∞—

Flame retardant According to NBN C 30-004

category F2

E L K A B E L

Page 132: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 132/430

131

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu / Al conductors PVC insulation Armour- st. tapes-screen PVC sheath

E L K A B E L

Construction dataEVAVB, EVAVB-F2 3.6/6 kV

Number of conductors andnominal cross section

Thicknessof insulation

Thicknessof steel

tapes

Max.resistance of

the armour

Thickness ofsheath

Cable diameterapprox.

Mass of

Cuapprox.

Mass of cableapprox.

N ı mm2 mm mm Ωkm mm mm kg/km kg/km

3x25rm3x35rm3x50sm3x70sm3x95sm

3x120sm3x150sm3x185sm3x240sm

3.23.23.23.23.43.43.43.43.6

0.50.50.50.50.70.70.70.70.7

1.61.351.151.000.900.800.750.700.65

2.22.22.22.22.42.62.62.83.0

37.840

38.441.446.449.552.455.161.6

85011701640226030303800471057807440

26703075298037205020592068808070

10150

EVAVB ; EVAVB-F2

Page 133: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 133/430

Technical data

132

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking elements aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 8.7/15kV , 12/20kV, Ë 20.8/36 kVand frequency 50 Hz in urban and district electrical networks and for electrical supply of transformer's substations,

small and medium industrial plants. They are suitable for use in distribution installations, electric power stations andindustrial systems. The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, incable ducts, conduits and shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

E X e C W BE A X e C W B

Uo/U - 8.7/15 kV, 12/20kV, 20.8/36 kVNBN C 33 - 323

Cable construction

Construction According to NBN C 3-323

Conductors —u and Al stranded compacted,according to IEC 60228 cl.2(NBN C 30-228)

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- semi-conductive XLPEconductive layer compound

Water resisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Water resistingelement - water absorbing insulating tape

Sheath PE compound tipe HDPE

to NBN C 3-323

Color Black or Red

Conductor resistance at20∞C

According to IEC60228class 2

(NBN C 30-228)

Operating temperature 90∞— continuous operation

Overload temperature 120∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 8.7/15; 12/20; 20,8/36 kV

Highest system voltageUo/U, no more than

8.7/15; 12/20; 20.8/36 kV17.5 kV; 24 kV; 41.5kV

Test voltage Uo/U AC ( ) - 5 min

8.7/15; 12/20; 20.8/36 kV35 kV; 48 kV; 83 kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 15∞—

Temperature of

exploitationTests -30 to 50∞—according to NBN C 33 323

Force of strain in laying Nmax.where:

Al cores - 30*n*S coreCu cores - 50*n*S coreN is number of cores andS is cross section of coresin mm

E L K A B E L

Page 134: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 134/430

133

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PE sheath

E L K A B E L

Construction dataEXeCWB; EAXeCWB 8.7/15; 12/20kV; 20.8/36 kV

Number of conduc-tors and nominal

cross section

Thic-kness of

insulation

Thic-kness of

sheath

Nominalcross

section ofscreen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of

Alapprox.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 kg/km kg/km kg/km kg/km kg/km

8.7/15 kV1x25 rm /161x50 rm /161x95 rm /25

1x150 rm /251x240 rm /251x400rm /35

12/20kV1x25 rm /161x50 rm /16

1x95 rm /251x150 rm /251x240 rm /251x400rm /35

20.8/36 kV1x120 rm /251x150 rm /251x240 rm /251x400 rm /35

EXeCWB EAXeCWB

265265265265265363

265265

265265265363

265265265363

782905

1128138417862541

860989

1233150019052672

1805197124453293

4.54.54.54.54.54.5

5.55.5

5.55.55.55.5

8,88,88,88,8

2.62.62.62.93.13.3

2.62.6

2.73.03.13.3

3.03.23.43.6

161625252535

1616

25252535

25252535

26.829.032.535.940.047.3

29.231.4

35.038.442.749.6

43.545.349.856.9

68130260405665

1060

68130

260405665

1060

330405665

1060

93912001723230833114953

10171285

1828242534305084

2555289639705705

480690

1120159524553835

490690

1120159524553835

1345159524553835

mm

Page 135: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 135/430

Technical data

134

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking elements, aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U U 8.7/15kV , 12/20kV, Ë 20.8/36 kVand frequency 50 Hz in urban and district electrical networks and for electrical supply of transformer's substations,

small and medium industrial plants. They are suitable for use in distribution installations, electric power stations andindustrial systems. The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, incable ducts, conduits and shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

E X e C V BE A X e C V B

Uo/U - 8.7/15 kV, 12/20kV, 20.8/36 kVNBN C 33 - 323

Cable construction

Construction According to NBN C 33-323

Conductors —u and Al stranded compacted,according to IEC 60228 cl.2(NBN C 30-228)

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- semi-conductive XLPEconductive layer compound

Water resisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Water resisting water absorbing insulating tapeelement

Sheath PVC compound tipe ST2

Color Red

Conductor resistance at20∞C

According to IEC60228class 2

(NBN C 30-228)

Operating temperature 90∞— continuous operation

Overload temperature 120∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 8.7/15; 12/20; 20,8/36 kV

Highest system voltageUo/U, no more than

8.7/15; 12/20; 20.8/36 kV17.5 kV; 24 kV; 41.5kV

Test voltage Uo/U AC ( ) - 5 min

8.7/15; 12/20; 20.8/36 kV35 kV; 48 kV; 83 kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 15∞—

Temperature of

exploitationTests -30 to 50∞—according to NBN C 33 323

Force of strain in laying Nmax.where:

Al cores - 30*n*S coreCu cores - 50*n*S coreN is number of cores andS is cross section of coresin mm

E L K A B E L

Page 136: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 136/430

135

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PE sheath

E L K A B E L

Construction dataEXeCVB; EAXeCVB 8.7/15; 12/20kV; 20.8/36 kV

Number of conduc-tors and nominal

cross section

Thic-kness of

insulation

Thic-kness of

sheath

Nominalcross

section ofscreen

Cable diameterapprox. Mass of

Cuapprox.

Mass of

cableapprox.

Mass of

Alapprox.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 kg/km kg/km kg/km kg/km kg/km

8.7/15 kV1x25 rm /161x50 rm /161x95 rm /25

1x150 rm /251x240 rm /251x400rm /25

12/20kV1x50 rm /161x95 rm /25

1x150 rm /251x240 rm /251x400rm /35

20.8/36 kV1x120 rm /251x150 rm /251x240 rm /251x400 rm /35

EXeCVB EAXeCVB

265265265265265363

265265

265265363

265265265363

89010241263154819852792

11191384

168221162936

2022221127273635

4.54.54.54.54.54.5

5.55.5

5.55.55.5

8,88,88,88,8

2.62.62.62.93.13.3

2.62.7

3.03.13.3

3.03.23.43.6

161625252535

1625

252535

25252535

26.829.032.535.940.047.3

31.435.0

38.442.749.6

43.545.349.856.9

68130260405665

1060

130260

405665

1060

330405665

1060

104813191858247335105204

14141979

260736415348

2772313642526047

490690

1120159526614344

6901120

159526614344

1345159524553835

mm

Page 137: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 137/430

H I G H V O L T A G E

P O W E R C

A B L E S

E L K A B E L

Page 138: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 138/430

H I G H

V O L T A G E

P O WE R C A B L E S

E L K A B E L

Page 139: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 139/430

138

H I G H V O L T A

G E P O W E R C A

B L E S

Cable constructionConstruction According to IEC 60840/VDE

0276-632

Conductor —u and Al stranded compactedwires according to IEC 60228 cl.2and VDE 0295 cl.2

Inner semi- semi-conductive XLPE compoundconductive layer

Insulation XLPE compound

Outer semi- semi-conductive XLPEconductive layer compound

Waterresisting layer of semi-conductive waterelement absorbing tapes

Metal screen Cu wires concentrically laid and onecontact of Cu tape with thickness of0.1mm.

Wate resisting -I option - water absorbing insulatingelement tape

-II option - water absorbing powderand a layer of plastic tape

Sheath PE compoundtype ST7 according to IEC 60502type DMP 2 according to VDE 0276

Color black

Technical data

Conductor resistance at20∞C

According to IEC60228 class 2and VDE 0295 class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature

Nominal voltage Uo/U

250∞— /5 s max./

26/45 kV 38/66 kV

Highest system voltageUo/U, no more than 52 kV; 72.5 kV

Test voltage Uo/U AC (≈) - 30 min

26/45 kV 38/66 ÍV65 kV 90 kV

Partial discharge levelat 2*Uo

Bending radius, minmax. 5pC

15x D cable

Temperature of laying

Temperature ofexploitation

no less than (-5∞—)

-30 to 50∞—

Testsaccording to IEC 60840

according to VDE 0276-632

Application

The single-core cables are designed for transfer and distribution of electrical power with nominal voltage Uo/U 26/45/52,38/66/72.5 kV and frequency 50 Hz.They are suitable for fixed assembly and indoor installation, in cable ducts and conduits, over shelves and grilles in waterand directly underground in ditch and outdoor under shelter.

2XS(F )2YA2XS(F )2Y

Uo/U - 26/45/52 ÍV; 38/66/72.5kVIEC 60840 / DIN VDE 0276-632

E L K A B E L

Page 140: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 140/430

139

H I G H

V O L T A G E P O W

E R C A B L E S

Construction data 2XS(F)2Y, A2XS(F)2Y 26/45/52; 38/66/72.5 kV

Number of con-ductors and

nominal crosssection

Nominal crosssection of screen

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

·.ı mm2 mm2 mm kg/km kg/km kg/km kg/km kg/kmUo/U/Um 26/45/52

kV1x2401x3001x4001x500

Uo/U/Um38/66/72,5 kV

1x240

1x3001x4001x500

35353535

35

353535

55586164

64

666770

2454298038364807

2454298038364807

4050480056006800

4600

530063007800

649812

10431374

649

81210431374

363363363363

363

363363363

2500290032003600

3600410044005300

2’S(F)2Y A2XS(F)2Y

Cu / Al conductors XLPE insulation Cu screen PE sheath

E L K A B E L

Page 141: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 141/430

Cable construction

Construction According to IEC, VDE

Conductors Al stranded compacted, wiresaccording to IEC 60228 cl.2 VDE0295 cl..2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compoundOuter semi-conductive layer semi conductive XLPE compound

Metal screen Cu wires concentrically laid andone contact of Cu tape with thickness of 0.1mm.

Separating layer layer of plastic tape

Sheath PVC compound type ST2 accordingto IEC 60502 type DMV 6according to VDE 0276

Color red

Technical data

Al conductors XLPE insulation Cu screen PVC sheath

Aluminium current core

- circular multiwire compacted- nominal cross-section

- diametermm2 50mm 8.2

Insulation thickness

Metal screen cross-section

mm 9.0

mm2 16Sheath thickness

Outer diameter approx.Mass of core

mm 2.5mm 37.2

kg/km 131

Mass of cableBending radius

kg/km 1297m 0.65

single bending Òm min 60

Electrical characteristics

Electrical resistance of core atDC and 20∞C Ω/km 0.641

Electrical resistance of screen atDC and 20∞C Ω/km 1.15

Electrical resistance of insulation MΩ.km 1*105

Operating capacitance µF/km 0.1387Maximum allowed ambiend tem-perature

90∞ C

Tests

Test voltage /15 min/

AC voltageDC voltage

70kV225kV

Partial discharge atU=50 kV - max 5pC

Dielecttric loss / tgδ /, max. 30.104

Increase of tgδ / tgδ/

U between 15-38 kVU between 38-89 kV

10.10410.104

140

Application

The cables are for power supply of electrostatic filters to 75 kV.Conditions for laying - underground, in premises, in cable ducts and conduits and outdoor under shelter.

H I G H V O L T A

G E P O W E R C A

B L E S

A2XSY 1ı50rm/16

ELFILT

U ‰Ó 75 kVsimilar to

IEC 60502 and IEC 60840

E L K A B E L

Page 142: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 142/430

141

H I G H V O L T A G E P O WE R C A B L E S

Cable construction

Construction According to IEC, VDE

Conductors Al stranded compacted, wiresaccording to IEC 60228 cl.2 VDE0295 cl..2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compoundOuter semi-conductive layer semi conductive XLPE compound

Metal screen Cu wires concentrically laid andone contact of Cu tape with thickness of 0.1mm.

Separating layer layer of plastic tape

Sheath PVC compound type ST2 according

to IEC 60502 type DMV 6according to VDE 0276

Color red

Technical data

Al cores XLPE insulation Cu screen PVC sheath

Application

The cables are for power supply of electrostatic filters to 111 kV.Conditions for laying - underground, in premises, in cable ducts and conduits and outdoor under shelter.

U ‰Ó 111 kVsimilar to

IEC 60502 and IEC 60840

Aluminium current core

- circular multiwire compacted- nominal cross-section

- diametermm2 50mm 8.2

Insulation thickness

Metal screen cross-section

mm 11.0

mm2 16Sheath thickness

Outer diameter approx.Mass of core

mm 2.5mm 40.0

kg/km 131

Mass of cableBending radius

kg/km 1524m 0.65

single bending Òm min 60

Electrical characteristics

Electrical resistance of core at DCand 20∞C

Ω/km 0.641

Electrical resistance of screen atDC and 20∞C

Ω/km 1.15

Electrical resistance of insulation MΩ.km 1*105

Operating capacitance µF/km 0.11

Maximum allowed ambiendtemperature

90∞ C

Tests

Test voltage /15 min/

AC voltageDC voltage

111kV333kV

Partial discharge atU=50 kV - max pC 10

Dielecttric loss / tgδ /, max. 30.104

Increase of tgδ / tgδ/

U between 15-38 kVU between 38-89 kV

10.10410.104

E L K A B E L

Page 143: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 143/430

P O W E R

C A B L E S ,

F L A M E R E T A R D A N T

E L K A B E L

Page 144: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 144/430

P O WE R C A B L E S ,

F L A ME R E

T A R D A N T

E L K A B E L

Page 145: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 145/430

Cable construction

Construction According to VDE 0276 part 603

Conductor solid or multi-strand Cu wires class 1or 2 acc. VDE 0295 (IEC 60228)

Insulation PVC flame retardant, degree of flameretardancy

Core identification according to VDE 0293

Inner sheath tapes and filling compound

Sheath PVC flame retardant, degree of flameretardancy category A

Color black

Technical data

144

Application

These cables are designed for transfer and distribution of electrical power with nominal voltage U 0 / U 0 6/1 kV, fre-

quency 50Hz and surroundings, which require non-proliferation of flames. NYYfr-0/J is used in power plants, industrialand switching installations, for street lighting, domestic power supply connections, in secondary distribution networksand other.

Note: Other core configuration and special constructions manufactured upon request.Cables with same construction may produced according to IEC 60502.

NYYf r -0 /J Uo/U - 0.6/1 kV VDE 0276 part 603

P

O W E R C A B L E S

L O W

V O L T A G E , F L A M E R E T A R D A N T

Conductor resistance at 20 Ó—According to VDE 0295

class 1 or 2 (IEC 60228)

Max. conductor temperature 70Ó—

Max. short circuit temperature +160 Ó—, not more than 5 sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 4 kV 50 Hz

Bending radius

-single core 15 cable diameter

-multi core 12 cable diameter

Flame retardancy BDS IEC 332-3/82, Category A

Color coding

Single core - black or yellow/greenDouble core - light blue and brown or yellow-green and black

3 - core 4 - core 5 - core Multiple core

brown, black, greyor

yellow/green, light blue, brown

light blue, brown, black, greyor

yellow/green, brown, black, grey

light blue, brown, black, grey,black

oryellow/green, light blue, brown,

black, grey

Black with number markingor

black with number mark on coresand yellow/green core in the outer

cover

E L K A B E L

Page 146: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 146/430

145

P O W

E R C A B L E S L O

WV O L T A G E ,F L

A ME R E T A R D A N T

Cu conductors PVC insulation PVC sheath

Construction data NYYfr- 0/JNumber ofcond. andnominal

cross sec-tion

Form ofconductor

Cablediameterapprox.

Mass ofCu

Mass ofcable

approx

N ı mm2 mm kg/km kg/km

Construction data NYYfr- 0/JNumber ofcond. andnominal

cross sec-tion

Form ofconductor

Cablediameterapprox.

Mass ofCu

Mass ofcable

approx

N ı mm2 mm kg/km kg/km

1 x 1,5 re 7,1 14 631 x 2,5 re 7,5 23 761 x 4,0 re 8,4 37 1041 x 6,0 re 8,9 56 128

1 x 10,0 re 9,7 94 1831 x 16,0 re 10,7 149 2471 x 25,0 rm 12,7 243 3591 x 35,0 rm 13,9 337 4621 x 50,0 rm 15,4 454 6031 x 70,0 rm 17,1 656 8171 x 95,0 rm 19,4 911 1092

1 x 120,0 rm 20,8 1147 13341 x 150,0 rm 22,7 1415 1627

1 x 185,0 rm 25,0 1770 20131 x 240,0 rm 27,8 2327 25981 x 300,0 rm 30,7 2887 32001 x 400,0 rm 34,1 3692 40481 x 500,0 rm 38,1 4725 5141

2 x 1,5 re 12,2 28 1922 x 2,5 re 12,9 46 2292 x 4,0 re 14,9 75 3152 x 6,0 re 15,9 112 382

2 x 10,0 re 17,5 188 5092 x 16,0 re 19,4 298 6762 x 25,0 rm 23,5 485 10272 x 35,0 rm 25,7 673 13012 x 50,0 rm 29,1 908 17032 x 70,0 rm 32,1 1312 2312

2 x 95,0 rm 38,0 1822 30933 x 1,5 re 12,1 43 2013 x 2,5 re 12,9 70 2473 x 4,0 re 15,0 112 3503 x 6,0 re 16,1 168 435

3 x 10,0 re 18,0 282 6063 x 16,0 re 20,1 447 8283 x 25,0 rm 24,4 728 12603 x 35,0 rm 26,7 1010 16223 x 50,0 rm 30,4 1363 21393 x 70,0 sm 29,2 1968 23803 x 95,0 sm 33,2 2732 3233

3 x 120,0 sm 35,4 3440 3962

3 x 150,0 sm 39,2 4245 48673 x 185,0 sm 42,7 5311 60463 x 240,0 sm 48,1 6981 78693 x 300,0 sm 53,5 8661 9702

3 x 25,0+16 sm re 25,4 876 14223 x 35,0+16 sm re 27,7 1159 17903 x 50,0+25 sm rm 29,2 1605 20913 x 70,0+35 sm rm 33,4 2304 28203 x 95,0+50 sm rm 37,8 3187 3824

3 x 120,0+70 sm rm 40,8 4096 47793 x 150,0+70 sm rm 44,8 4901 56853 x 185,0+95 sm rm 49,3 6222 7163

3 x 240,0+120 sm rm 55,3 8128 9227

3 x 300,0+150 sm rm 60,9 10076 113634 x 1,5 re 12,9 57 2324 x 2,5 re 13,8 93 2894 x 4,0 re 16,2 149 4194 x 6,0 re 17,4 223 525

4 x 10,0 re 19,5 376 7414 x 16,0 re 21,8 595 10244 x 25,0 rm 27,2 970 16154 x 35,0 rm 30,1 1346 20954 x 50,0 sm 29,2 1817 23114 x 70,0 sm 33,4 2624 31424 x 95,0 sm 37,8 3643 4281

4 x 120,0 sm 40,8 4587 52564 x 150,0 sm 44,8 5660 64424 x 185,0 sm 49,3 7082 8033

4 x 240,0 sm 55,3 9308 104264 x 300,0 sm 60,9 11548 128505 x 1,5 re 13,7 71 2725 x 2,5 re 14,8 116 3415 x 4,0 re 17,4 187 4945 x 6,0 re 19,0 279 635

5 x 10,0 re 21,6 470 9115 x 16,0 re 24,1 744 12625 x 25,0 rm 29,9 1213 19645 x 35,0 rm 33,5 1683 25935 x 50,0 rm 38,1 2271 34355 x 70,0 rm 43,3 3280 46385 x 95,0 rm 50,1 4554 6318

E L K A B E L

Page 147: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 147/430

Cable construction

Construction According to VDE 0276 part 603

Conductor solid or multi-strand Cu wires class 1or 2 acc. VDE 0295 (IEC 60228)

Insulation PVC flame retardant, degree of flameretardancy

Core identification according to VDE 0293

Inner sheath tapes and filling compound

Sheath PVC flame retardant, degree of flameretardancy category A

Color black

Technical data

146

Application

These cables are designed for transfer and distribution of electrical power with nominal voltage U 0 / U 0 6/1 kV, fre-

quency 50Hz and surroundings, which require non-proliferation of flames. NYCY-FR is used in power plants, industrialand switching installations, for street lighting, domestic power supply connections, in secondary distribution networksand other.These cables are preferentially used for underground application as well as for interior installation in roomand cableducts and for outdoor and applications, for indoor installations, where greater mechanical protection an pro-tection against accidental contact is required if damaged.

Note: Other core configuration and special constructions manufactured upon request.

NYCY - FR Uo/U - 0.6/1 kV VDE 0276 part 603

P

O W E R C A B L E S

L O W

V O L T A G E , F L A M E R E T A R D A N T

Color coding

Single core - blackDouble core - light blue and brown

3 - core 4 - core

brown, black, grey light blue, brown, black, grey

Conductor resistance at 20 Ó—According to VDE 0295

class 1 or 2 (IEC 60228)

Max. conductor temperature 70Ó—

Max. short circuit temperature +160 Ó—, not more than 5 sec

Rated voltage Uo/U 0.6/1 kV

Test voltage AC - 4 kV 50 Hz

Bending radius

-single core 15 cable diameter

-multi core 12 cable diameter

Flame retardancy BDS IEC 332-3, Category A

E L K A B E L

Page 148: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 148/430

147

P O W

E R C A B L E S L O

WV O L T A G E ,F L

A ME R E T A R D A N T

Cu conductorsPVC insulationCu concentric conductor PVC sheath

Construction data NYCY -FR 0.6/1 kV

Number of wires andnominal cross section Shape

Concentricconductor

cross section

Outer diameterof cableapprox.

Cu weight

Cable weightapprox.

N ı mm2 mm2 mm kg/km kg/km

1 x 1,5/1,5 re 1,5 7,9 27 981 x 2,5/2,5 re 2,5 8,5 47 1221 x 4,0/4,0 re 4,0 9,4 74 1631 x 6,0/6,0 re 6,0 9,9 108 2031 x 10/10 re 10 11,3 182 2861 x 16/16 re 16 12,8 297 4101 x 25/25 rm 25 12,9 465 6061 x 35/35 rm 35 16,4 654 807

2 x 1,5/1,5 re 1,5 13,0 45 2302 x 2,5/2,5 re 2,5 13,7 68 2732 x 4,0,/4,0 re 4,0 15,9 110 3752 x 6,0/6,0 re 6,0 17,1 164 4582 x 10/10 re 10 19,1 274 619

2 x 16/16 re 16 21,0 435 8412 x 25/25 rm 25 25,1 703 12762 x 35/35 rm 35 27,8 980 16422 x 50/50 rm 50 31,5 1343 2193

3 x 1,5/1,5 re 1,5 13,5 56 2523 x 2,5/2,5 re 2,5 14,3 90 3053 x 4,0/4,0 re 4,0 16,6 147 4253 x 6,0/6,0 re 6,0 17,7 243 5283 x 10/10 re 10 20,0 365 7243 x 16/16 re 16 22,1 580 9993 x 25/16 rm 16 27,8 855 14403 x 25/25 rm 25 26,6 938 15243 x 35/16 rm 16 29,1 1127 18133 x 35/35 rm 35 29,4 1317 19873 x 50/25 rm 25 32,7 1581 2415

3 x 35/35 sm 35 27,1 1339 16443 x 35/16 sm 16 26,6 1161 16273 x 50/25 sm 25 29,6 1593 21743 x 50/50 sm 50 30,6 1819 22603 x 70/35 sm 35 33,6 2265 29323 x 70/70 sm 70 34,1 2584 30973 x 95/50 sm 50 38,2 3151 40043 x 95/95 sm 95 39,4 3692 4336

3 x 120/70 sm 70 38,3 4038 49253 x 120/120 sm 120 41,6 4443 51243 x 150/70 sm 70 44,7 4827 5890

3 x 150/150 sm 150 45,8 5543 63523 x 185/95 sm 95 49,0 6051 7329

3 x 240/120 sm 120 54,5 7881 93994 x 1,5/1,5 re 1,5 14,3 70 284

4 x 2,5/2,5 re 2,5 16,3 136 3824 x 4,0/4,0 re 4,0 17,8 183 4944 x 6,0/6,0 re 6,0 19,0 297 6204 x 10/10 re 10 21,5 457 8604 x 16/16 re 16 23,8 725 11964 x 25/16 rm 16 29,0 1090 17644 x 35/16 rm 16 32,0 1456 22464 x 50/25 rm 25 36,4 1998 30244 x 35/16 sm 16 29,8 1495 20604 x 50/25 sm 25 33,1 2044 27304 x 70/35 sm 35 38,4 2911 37584 x 95/50 sm 50 42,6 4041 5054

4 x 120/70 sm 70 43,1 5162 62464 x 150/70 sm 70 50,7 6214 75484 x 185/95 sm 95 55,3 7826 9374

4 x 240/120 sm 120 62,3 10150 12124

E L K A B E L

Page 149: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 149/430

148

Application

Powet cable suitable for transmission of electricity up to 1000 V, used in house and industrial installations. Appropriate

for internal installation even in damp surroundings and for outdoor applications-whether there in possibility for directinstalation.

FG70R Uo/U - 600/1000 VIEC 60502-1

P

O W E R C A B L E S

L O W

V O L T A G E , F L A M E R E T A R D A N T

Color coding

Number of cores Color of conductors without yellow/green Color of conductors with yellow/green

1 Black or other -

2 blue; brown -

3 brown, black, grey yellow/green, blue, brown

4 blue, brown, black, grey yellow/green, brown, black , grey

5 blue, brown, black, grey, black yellow/green, blue, brown, black, grey

5 and above black with number mark on cores

black with number mark on cores and

yellow/green in the outer cover

Cable construction

Construction According to IEC 60502-1

Conductor Cu wires, flexible class 5,according to IEC 60228

Insulation rubber compound Type HEPRaccording to IEC 60502-1on base HEPR rubber

Core identification according to VDE 0293

Inner Sheath Flame retarding PVC compound

Outer Sheath PVC compound fire retardant andreduced corrosive gas emission

Color Grey RAL 7035

Technical data

Conductor resistance at 20ÓCAccording IEC 60228

class 5

Operating temperature max

at the conductor max

+90oC in operation

+250oC in the event of a short cir-cuit

Temperature minimum 0oC

Rated voltage Uo/U 0.6/1kV

Test voltage AC, 50 Hz 4kV

Minimum bending radius 4x cable diameter

Testing according:Flame test

Test class C accordingIEC 60332-3

E L K A B E L

Page 150: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 150/430

149

P O W

E R C A B L E S L O

WV O L T A G E ,F L

A ME R E T A R D A N T

Cu conductorsHEPR insulationFlame retarding PVC sheath

Construction data FG7OR 600/1000 V

Number of con-ductors and

nominal crosssection

Outerdiameterapprox.

Mass of CuMass of

cableapprox

N ı mm2 nom/mm kg/km kg/km

Construction data FG7OR 600/1000 V

Number of con-ductors and

nominal crosssection

Outerdiameterapprox.

Mass of CuMass of

cableapprox

N ı mm2 nom/mm kg/km kg/km

1x1,5 5.8 11.9 47.41x2,5 6.2 19.8 58.51x4,0 6.7 32.4 76.01x6,0 7.6 48.2 101.41x10 8.8 87.3 152.21x16 9.8 134.9 210.41x25 11.7 206.4 306.61x35 13 293.7 408.61x50 15.2 410.5 564.91x70 17.5 584.7 773.21x95 20 774.3 1003.6

1x120 21.4 988.6 1243.91x150 24.3 1245.5 1569.6

1x185 25.7 1507.7 1859.61x240 30.4 1976.3 2410.11x300 33.6 2498.0 2986.32x1,5 11.6 24.3 179.52x2,5 12.3 40.4 212.52x4.0 13.4 66.0 265.82x6.0 15.2 98.3 349.52x10 17.6 177.9 501.92x16 20 275.0 686.52x25 23.8 420.6 987.82x35 26.4 598.5 1278.22x50 30.4 836.5 1724.52x70 35.4 1191.6 2371.32x95 39.6 1577.9 2998.4

2x120 42.8 2014.8 3672.4

2x150 47.8 2538.3 4569.03x1,5 12.1 36.4 199.03x2,5 12.9 60.6 210.03x4,0 14.0 99.0 307.03x6,0 16.0 147.5 408.0

3x10,0 18.6 270.0 600.03x16,0 21.2 412.5 834.03x25,0 25.2 630.0 12103x35,0 28.5 998.0 16203x50,0 32.3 1255 21603x70,0 37.7 1788 29803x95,0 42.2 2370 3776

3x120 45.7 3022 46503x150 51.5 3808 58403x185 54.9 4610 69203x240 65.4 6040 92004x1.5 12.9 48.5 225.64x2.5 13.7 81 2774x4 15.0 132.0 360.04x6 17.2 197.0 483.0

4x10 20.1 356.0 720.04x16 22.9 550.0 990.04x25 27.5 840.0 1450.0

3x35+25 30.3 1110 1990.03x50+35 33.5 1460.0 2560.0

3x70+35 38.8 2090.0 3550.03x95+50 44.1 2790.0 4590.0

3x120+70 48.0 3620.0 5700.03x150+95 54.6 4600.0 7250.03x185+95 57.2 5400.0 8330.0

3x240+150 68.4 7310.0 11350.05x1.5 13.7 60.6 2575x2.5 14.6 101.0 3205x4.0 16.1 165.0 420.05x6,0 18.6 246.0 570.0

5x10,0 21.8 450.0 850.05x16,0 25.0 690.0 1200.07x1,5 14.6 85.0 297.07x2,5 15.7 142.0 376.0

10x1.5 17.6 122.0 410.0

10x2.5 19.0 202.0 530.012x1,5 18.0 145.5 450.012x2,5 19.5 242.0 580.019x1,5 20.6 230.0 605.019x2,5 22.4 380.0 805.024x1,5 24.0 290.0 770.024x2,5 26.0 485.0 1020.027x1.5 24.5 328.0 820.027x2.5 26.6 546.0 1105.030x1,5 25.3 365.0 890.030x2,5 27.5 607.0 1200.0

E L K A B E L

Page 151: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 151/430

150

P

O W E R C A B L E S

L O W

V O L T A G E , F L A M E R E T A R D A N T

E L K A B E L

Uo/U - 0.6/1 kVIEC 60502-1,XYRYf r -0 /J

A2XYRYf r -0 /J

Cable construction

Construction According to IEC 60502-1

Conductor solid or multi-strand Al or Cu wiresclass 1 or 2 acc. IEC 60228

Insulation XLPE COMPOUND

Color Double core - light blue and brow oryellow-green and black3 - core - brown, black, greyor yellow/green, light blue, brown4 - core - light blue, brown, black, greyor yellow/green, brown, black, grey5 - core - light blue, brown, black, greyblackor yellow/green, light blue, brownblack, greyMultiple core - Black with numberedpair in each cover

Inner sheath PVC flame retardant, degree of flameretardancy

Armour galvanized iron wirestwisted concentrically

Sheath PVC flame retardant, degree of flameretardancy category A

Color Black

Technical data

Application

These cables are designed for transfer and distribution of electrical power with nominal voltage U 0 / U 0 6/1 kV, fre-quency 50Hz and surroundings, which require non-proliferation of flames. 2XYRYfr and A2XYRYfr is used in powerplants, industrial and switching installations, for street lighting, domestic power supply connections, in secondary distri-bution networks and other.These cables are preferentially used for underground application as well as for interior instal-lation in room and cableducts and for outdoor and applications, for indoor installations, where greater mechanical pro-tection an protection against accidental contact is required if damaged.

Conductor resistance at 20oC According class 1 or 2IEC 60228

Max. conductor temperature 90o— continuous operation

Overload temperature 130o— /100h/per year m‡ı./

Short circuit temperature 250o— /5 s max./

Nominal voltage Uo/U 0.6/1 kV

Highest system voltage 1.2 kV

Test voltage AC - 5 min.between cores - 3.5 ÍV

between core and screen -3.5 ÍV

Bending radius, min. - 15x D cable

Temperature of laying no less than 0o—

Temperature of exploitation -30 to 50o—

Flame retardancy BDS IEC 332-3/82, Category A

Page 152: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 152/430

Cu/Al conductors XLPE insulation PVC sheath Armour St. wires PVC sheath

Construction data 2XYRYfr, A2XRYfr 0.6/1 kVNumber ofcond. and

nominal crosssection

Thickness ofinsulation

Thickness ofsheath

Cablediameterapprox.

2XYRYfr A2XYRYfr

Mass of Cuapprox.

Cable weightapprox.

Mass of Alapprox.

Cable weightapprox.

mm mm mm kg/km kg kg/km kg

2 ı 2.5 rm 0.7 1.8 14.1 46 421 14 3882 ı 4 rm 0.7 1.8 15.2 75 500 23 448

2 ı 10 rm 0.7 1.8 18.9 188 863 56 7292 ı 16 rm 0.7 1.8 20.3 298 1050 90 8402 ı 25 rm 0.9 1.8 24.9 485 1584 140 12362 ı 50 rm 1.0 1.9 29.2 908 2376 269 17302 x 95 rm 1.1 2.1 38.2 1822 4058 539 27623 ı 1.5 rm 0.7 1.8 16.5 43 596 13 5663 ı 2.5 rm 0.7 1.8 16.5 70 619 21 5703 ı 4 rm 0.7 1.8 17.5 112 713 36 6363 ı 6 rm 0.7 1.8 17.8 168 774 51 656

3 ı 10 rm 0.7 1.8 19.8 282 987 85 7883 ı 16 rm 0.7 1.8 21.3 447 1234 135 9193 ı 25 rm 0.9 1.8 25.4 728 1878 210 13553 ı 35 rm 0.9 1.8 27.8 1010 2320 290 1593

3 ı 50 rm 1.0 1.9 30.9 1363 2901 385 19143 ı 70 sm 1.1 2.1 34.6 1968 3750 585 23534 ı 2.5 rm 0.7 1.8 16.6 93 933 28 8674 ı 4 rm 0.7 1.8 17.5 149 1060 46 9564 ı 6 rm 0.7 1.8 19.1 223 1248 68 1091

4 ı 10 rm 0.7 1.8 21.2 376 1576 112 13094 ı 16 rm 0.7 1.8 23.6. 595 2278 180 18594 ı 25 rm 0.9 1.8 27.5 970 3059 270 23524 ı 35 rm 0.9 1.9 30.2 1346 3701 390 27364x50 sm 1,4 2.1 34.4 1817 3535 520 22254x70 sm 1,4 2,1 38.9 2624 4701 760 28184x95 sm 1,6 2,1 43.0 3643 6017 1060 3408

4x120 sm 1,6 2,2 47.5 4587 7626 1340 43464x150 sm 1,8 2,4 51.8 5660 9144 1650 50944x185 sm 2 2,5 56.0 7082 10976 2100 5945

4x240 sm 2.2 2,6 62.3 9308 13861 2720 72077 x 1.5 rm 0.7 1.8 17.0 96 960 30 8947 x 2.5 rm 0.7 1.8 18.2 160 1119 49 1007

12 x 1.5 rm 0.7 1.8 20.4 165 1294 51 117919 x 2.5 rm 0.7 1.8 25.6 435 2277 133 1972

151

P O W

E R C A B L E S L O

WV O L T A G E ,F L

A ME R E T A R D A N T

E L K A B E L

Page 153: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 153/430

Cable construction

Construction According to IEC 60502-1

Conductor solid or multi-strand Al or Cu wiresclass 1 or 2 acc. IEC 60228

Insulation XLPE COMPOUND

Inner sheath PVC flame retardant, degree of flameretardancy

Armour Al wires twisted concentrically

Sheath PVC flame retardant, degree of flameretardancy category A

Color Black

Technical data

152

Application

These cables are designed for transfer and distribution of electrical power with nominal voltage U 0 / U 0 6/1 kV, fre-

quency 50Hz and surroundings, which require non-proliferation of flames. 2XYRaY-FR and A2XYRaY-FR is used inpower plants, industrial and switching installations, for street lighting, domestic power supply connections, in secondarydistribution networks and other.These cables are preferentially used for underground application as well as for interiorinstallation in room and cableducts and for outdoor and applications, for indoor installations, where greater mechanicalprotection an protection against accidental contact is required if damaged.

Uo/U - 0.6/1 kVIEC 60502-1

P

O W E R C A B L E S

L O W

V O L T A G E , F L A M E R E T A R D A N T

E L K A B E L

Conductor resistance at 20oC According class 1 or 2IEC 60228

Max. conductor temperature 90o— continuous operation

Overload temperature 130o— /100h/per year m‡ı./

Short circuit temperature 250o— /5 s max./

Nominal voltage Uo/U 0.6/1 kV

Highest system voltage 1.2 kV

Test voltage AC - 5 min. between cores - 3.5 ÍVbetween core and screen - 3.5 ÍV

Bending radius, min. - 15x D cable

Temperature of laying no less than 0Ó—

Temperature of exploitation - 30 to 50o—

Flame retardancy IEC 332-3, Category A

Construction data 2XYRaY-FR , A2XYRaY-FR 0.6/1 kV

Number ofcond. andnominal

cross section

Thickness ofinsulation

Thickness ofsheath

Cablediameterapprox.

2XYRaY-FR A2XYRaY-FRMass of Cu

appr.Cable weight

approx.Mass of Al

appr.Cable weight

approx.

mm mm mm kg/km kg kg/km kg

1x25 rm 0.9 1.8 16.3 229 532 68 3701x35 rm 0.9 1.8 17.4 325 657 95 4251x50 rm 1.0 1.8 18.7 458 833 127 4981x70 rm 1.1 1.8 20.5 648 1073 190 6111x95 rm 1.1 1.8 22.9 885 1417 260 785

1x120 rm 1.2 1.8 24.5 1120 1699 325 8961x150 rm 1.4 1.8 26.3 1378 2028 405 10461x185 rm 1.6 1.9 28.4 1770 2643 510 13711x240 rm 1.7 2.0 31.2 2327 3335 665 16561x300 rm 1.8 2.1 34.6 2887 4118 830 2040

2XY Ra Y - FRA2XY Ra Y -FR

Cu/Al conductors XLPE insulation PVC sheath Armour Al wires PVC sheath

Page 154: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 154/430

Technical data

Application

The three-core cables flame retardant with insulation of cross-linked polyethylene (XLPE) are designed for transfer anddistribution of electrical power with nominal voltage Uo/U 6/10 kV and frequency 50 Hz. The cables are manufacturedwith sheaths of flame retardant materials.They are suitable for use in distribution installations, electric power stations and substations for fixed indoor assemblyin cable ducts and conduits, over shelves and grilles. They should not be laid directly underground or in water.The cables should not be laid in or near nuclear stations.

Cable construction

Construction According to IEC 60502-2and IEC 60332-3

Conductor —u and Al stranded compacted wiresto IEC 60228 cl.2

Inner semi- semi-conductive XLPE compoundconductive layerInsulation XLPE compound

Outer semi- semi-conductive XLPE compoundconductive layer and semi-conductive tapeMetal screen -I option - Cu tapes laid with overlap

over each phase-II option - Cu wires laid concentrically

Cable assembly three insulated and screenesdphases are twisted with andtape support

Inner sheath I -option - fillings and sheat -exstruded PVC compound flameretardant - kat AII-option - fillings and tapes -kat B and C

Sheath PVC compound flame retardantColor black

Construction data 2XSEY-FR, A2XSEY-FR 6/10 kVNumber ofcond. andnominal

cross section

Thickness ofinsulation

Thickness ofsheath

Nominalcross-sec-

tion ofscreen

Cablediameterapprox.

2XSEY-FR A2XSEY-FR

Mass of Cuappr.

Cable weightapprox.

Mass of Alappr.

Cable weightapprox.

N ı mm2 mm mm mm2 mm kg/km kg kg/km kg

6/10kV3x35rm/16 3,4 2.5 16 47.6 1010 3276 298 26193x50rm/16 3,4 2.6 16 50.3 1363 3834 404 29233x70rm/16 3,4 2.7 16 54.4 1968 4784 584 34703x95rm/16 3,4 2.8 16 58.4 2732 5930 809 4103

3x120rm/16 3,4 2.9 16 61.6 3440 6923 1023 46273x150rm/25 3,4 3.0 25 64.4 4245 8217 1257 53793x185rm/25 3,4 3.2 25 68.5 5311 9691 1579 61443x240rm/25 3,4 3.4 25 74.3 6981 11963 2071 7331

153

MI D D L E V O L T A G E P

O WE R C A B L E S -T H R E E C O R E ,F

L A ME R E T A R D A N T

E L K A B E L

Conductor resistance at 20oC According to IEC 60228

Max. conductor temperature 90o— continuous operation

Overload temperature 130o— /100h/per year m‡ı./

Short circuit temperature 250o— /5 s max./

Nominal voltage Uo/U 6/10 kV

Highest system voltageUo/U, no more than

6/10 kV12 kV

Test voltage AC - 5 min.AC (~~) - 5 min

DC (=) - 15 min

6/10 kV21 kV67 kV

Bending radius, min. - 15x D cable

Temperature of laying no less than -5Ó—

Temperature of exploitation - 30 to 50o—

Tests IEC 60 502

Flame retardancy IEC 332-3, Category A

Uo/U - 6/10 kVIEC 60502-2, IEC 60332-3 2XS EY - FR

A2XS EY -FRCu/Al conductors XLPE insulation Cu screen PVC sheath - flame retardant

Page 155: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 155/430

154

M I D D L E V O L T A G E

P O W E R C A B L E S - T H R E E C O R E

, F L A M E R E T A R

D A N T

E L K A B E L

Technical data

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 6/10 and frequency 50 Hz in urban and district electrical networks and forelectrical supply of transformer's substations, small and medium industrial plants. The cables are manufactured withsheaths of flame retardant materials.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

Uo/U 6/10 kVIEC 60502-2 , IEC 60332-3XS EY BY - FR

A2XS EY BY - FRCu / Al conductors XLPE insulation Cu screen Armour st. tapes PVC sheath flame retardant

Cable construction

Construction according to IEC 60502 -2

Conductor —u and Al stranded compacted,according to IEC 60228 class 2

Inner semi- conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- conductive layer semi-conductive XLPE compound

Metal screen over each phase -I option - Cu tapes laid with overlap over each phaseMetal screen -II option - Cu wires laid concentrically

Cable assembly Three insulated and screened phases are twisted withfillings and tape support

Inner sheatth I -option - exstruded PVC compound flame retardant -(bedding) kat A

II-option - exstruded PVC compound - kat B and C

Armour two steel tapes or two steel galvanized tapes

Sheath PVC compound flame retardant

Color Black or red

Conductor resistance at 20oC According to IEC 60228Max. conductor temperature 90o— continuous operation

Overload temperature 130o— /100h/per year m‡ı./Short circuit temperature 250o— /5 s max./

Nominal voltage Uo/U 6/10 kV

Highest system voltageUm, no more than

6/10 kV12 kV

Test voltage Uo/UAC (~~) - 5 min

DC (=) - 15 min

6/10 kV21 kV67 kV

Level of partial discharge at 2*Uo max. 5 pCBending radius, min. - 15x D cableTemperature of laying no less than -5Ó—

Temperature of exploitation - 30 to 50o—Tests according to IEC 60 502-2

Flame retardant IEC 602332-3, Kat A - 7l/mKat B(3.5l/m)and C(1.5l/m)

Construction data 2XSEYBY-FR, A2XSEYBY-FR 6/10

Number ofcond. andnominal

cross section

Thickness ofinsulation|

Thickness ofsheath

Nominalcross-sec-tion ofscreen

Cablediameterapprox.

2XSEYBY-FR A2XSEYBY-FRMass of Cu

appr.Cable weight

approx.Mass of Al

appr.Cable weight

approx.

N x mm2 mm mm mm mm kg/km kg kg/km kg

6/10kV3x35rm/16 3,4 2,5 16 48.4 1010 3639 298 29633x50rm/16 3,4 2,6 16 51.0 1363 4203 404 32923x70rm/16 3,4 2,7 16 55.0 1968 5117 584 38033x95rm/16 3,4 2.9 16 59.3 2732 6239 809 4412

3x120rm/16 3,4 3.0 16 62.5 3440 7178 1023 48823x150rm/25 3,4 3.1 25 66.4 4245 8433 1257 55953x185rm/25 3,4 3.2 25 70.5 5311 9831 1579 62853x240rm/25 3,4 3.4 25 76.3 6981 12001 2071 73373x300rm/25 3,4 3.7 25 83.2 8661 15023 2589 9255

Page 156: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 156/430

155

MI D D L E V O L T A G E P

O WE R C A B L E S -T H R E E C O R E ,F

L A ME R E T A R D A N T

E L K A B E L

Cable construction

Construction According to IEC 60502-2Conductor —u or Al stranded compacted,

according to IEC60228 class 2Inner semi- semi-conductive XLPE compoundconductive layer

Insulation XLPE compound

Outer semi- semi-conductive XLPE compoundconductive layer

Metal screen -I option - Cu tapeslaid with overlap over each phase-II option - Cu wires laid concentrically

Separating layer PVC compound -flame retardant Armour ¿l wires laid concentricallySheath PVC compound -- flame retardantColor black or red

Technical data

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution of

electrical power with nominal voltage Uo/U 6/10 kV and frequency 49 Hz to 61 Hz in urban and district electrical net-works and for electrical supply of transformer's substations, small and medium industrial plants. The cables are manu-factured with sheaths of flame retardant materialsThey are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

Uo/U - 6/10 kVIEC 60502-2, IEC 60332-3

Construction data 2XSYRaY-FR, A2XSYRaY-FR 6/10kV

Number ofcond. andnominal

cross section

Thickness ofinsulation

Diameter of Al wires -for armor

Thickness ofsheath

Cablediameterapprox.

2XSYRaY-FR A2XSYRaY-FRMass of Cu

appr.Cable weight

approx.Mass of Al

appr.Cable weight

approx.

N x mm2 mm mm mm mm kg/km kg kg/km kg

6/10kV1x50 rm 3.4 1.6 1.8 27.4 520 1200 130 8101x70 rm 3.4 1.6 1.9 29.2 720 1500 190 9701x95 rm 3.4 1.6 1.9 30.9 960 1800 260 11001x120rm 3.4 1.6 2.0 32.5 1200 2100 330 12301x150rm 3.4 2.0 2.1 34.9 1465 2550 405 14901x185rm 3.4 2.0 2.1 36.6 1795 2950 510 16651x240rm 3.4 2.0 2.2 39.2 2325 3600 665 19401x300rm 3.4 2.0 2.2 41.4 2925 4250 830 21551x400rm 3.4 2.0 2.4 44.6 3750 5180 1060 24901x500rm 3.4 2.5 2.5 49.2 4740 6550 1410 3220

2XS Y Ra Y - FRA2XS Y Ra Y - FR

Cu/Al conductors XLPE insulation Cu screen PVC sheath Armour Al wires PVC sheath flame retardant

Conductor resistance at 20oC According to IEC 60228 class 2

Max. conductor temperature 90o— continuous operation

Overload temperature 130o— /100h/per year m‡ı./

Short circuit temperature 250o— /5 s max./Nominal voltage Uo/U 6/10 kVHighest system voltage

Uo/U, no more than 12 kVTest voltage

AC (~~) - 5 min

Level of partial discharge at 2*Uo:

6/10 kV21kV67 kV

m‡ı 5pC

Bending radius, minBending radius adjacent to

joints or terminations, min

15x D cable

12x D cable

Temperature of laying no less than -5Ó—

Ambient temperatures - 30 to 50o—

Tests: Flame retardancy IEC 60332-3Kat B(3.5l/m)and C(1.5l/m)

Page 157: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 157/430

156

Application

Three-core cables with insulation of polyvinylchloride (PVC) - armored type are designed for transfer and distribution of

electrical power networks with voltage of 1000 V. The sheath is flame retardant.The cables are for fixed assembly in lines with unlimited difference levels, for underground, in cable ducts, conduits,shafts, trenches, pipes, shafts, over shelves and grills directly underground in ditch.

EVAVB-F2 Uo/U - 0.6/1 kVNBN C 33-121

and comment No 1 and 2

L O W

V O L T A G

E P O W E R C A B L E S

Color coding

2-cores: 3-cores: 4-cores:

black; blueblack; blue; brown

oryellow/green; black; blue

black; blue; brown; blackor

yellow/green; black; blue; brown;

Neutral core - blue

Protective core ( G ) -yellow/green

Cable construction

Construction According to NBN C 33-121

Conductor —u stranded compacted circular andsector, according toNBN C 33-121 (IEC 60228 class 2)

Insulation PVC compound

Inner sheath polymer material

Armour-screen two steel tapes, underneath the tapesare laid Cu wires for improvingconductivity

Sheath PVC compound, flame retardant

Color black

Technical data

Conductor resistance at 20oC NBN C 33-121 (IEC 228) class 2

Operating temperature 70Ó— continuous operation

Overload temperature 160Ó— /5 s max./

Nominal voltage Uo/U: 0.6/1kV

Highest system voltage,

no more than1100 V

Test voltage Uo/U

AC (~~) - 20 min

Between cores and between core

and screen (armor)- 13kV

Bending radius, min 15 x D cable

Temperature of laying No less than 0Ó—

Temperature of exploitation -15 to 70o—

Flame retardantAccording to NBN C 30-004

Category F2

E L K A B E L

Page 158: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 158/430

157

L OW

V OL T A G E P O

WE R C A B L E S

Cu conductors PVC insulation Armour/screen-st.tapes PVC sheath

Construction data EVAVB-F2

Number ofconductors andnominal cross

section

Thickness ofinsulation

Thicknessof

steel tapes

Armourresistance

max.

Thickness ofsheath

Cablediameterapprox.

EVAVB-F2

Mass ofCu

approx.

Mass ofcable

approx.N ı mm2 mm mm Ω/Ím mm kg/km kg/km

E L K A B E L

4x1.5re 0.8 Ù1.2 12.1 1.8 15 60 5004x2.5re 0.8 Ù 1.2 7.41 1.8 15.9 100 5904x4re 0.9 Ù 1.2 4.61 1.8 17.5 160 7254x6re 0.9 Ù 1.2 3.08 1.8 18.7 260 860

4x10re 1.1 Ù 1.2 2.4 2.0 22.0 420 12004x16rm 1.1 0.5 2.0 2.0 25.0 720 15504x25rm 1.3 0.5 1.6 2.0 29.5 1000 19004x35rm 1.3 0.5 1.35 2.0 32.0 1520 26004x50sm 1.4 0.5 1.15 2.2 34.0 2140 29604x70sm 1.4 0.5 1.0 2.2 37.3 2960 38604x95sm 1.6 0.5 0.9 2.4 42.3 3980 5100

4x120sm 1.6 0.5 0.8 2.4 46.2 5000 64004x150sm 1.8 0.5 0.75 2.6 51.0 6210 7750

4x185sm 2.0 0.5 0.7 2.8 55.8 7630 94504x240sm 2.2 0.5 0.65 3.0 62.2 9840 12000

3x16rm+10re 1.1 / 1.1 0.5 2.0 2.0 24.5 660 14603x25rm+16rm 1.3 / 1.1 0.5 1.6 2.0 28.7 1010 17403x35rm+16rm 1.3 / 1.1 0.5 1.35 2.0 31.0 1330 24003x50sm+25rm 1.4 / 1.3 0.5 1.15 2.2 32.9 1890 27303x70sm+35rm 1.4 / 1.3 0.5 1.00 2.2 37.0 2610 35003x95sm+50rm 1.6 / 1.4 0.5 0.9 2.2 42.0 3530 4500

3x120sm+70rm 1.6 / 1.4 0.7 0.8 2.4 43.1 4500 58503x150sm+70tm 1.8 / 1.4 0.7 0.75 2.6 47.1 5410 69003x185sm+95rm 2.0 / 1.6 0.7 0.7 2.8 51.7 6730 8500

3x240sm+120rm 2.2 /1.6 0.7 0.65 3.0 57.6 8640 10650

Page 159: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 159/430

Technical data

158

Application

The power insulated conductors flame retardant, with low halogen free smoke emission and corrosion at fire conditions

are suitable for use in electrical installations for Uo/U 300/500 V in:important objects - power stations (nuclear, thermal), transformer substations, metro, airport,public buildings - hospitals, hotels, theaters, cinemas, public and commercial centers,places with great concentration of people and material values whose safety in case of fire should be guaranteed.

The conductors are designed for laying over, in and under plasters in dry and wet premises as well as in brickwork"sand concrete. They are also suitable for outdoor use.The conductors should not be laid directly in vibro concrete or rammed concrete and directly under ground.

L O W

V O L T A

G E P O W E R C A

B L E S

H

A L O G E N F R E E ,

F L A M E R E T A R D A N T

N H X M H - 0

N H X M H - J

Uo/U - 300/500 VDIN VDE 0250 part 214

Conductor resistance at20∞C

according to VDE 0295(IEC60228) class 1 or 2

Operating temperature 70∞—

Short circuit temperature 160∞— / 5 s max./Nominal voltage Uo/U:

Test voltage300/500 V ¿— - 2kV

Bending radius, min 4xD cable

Tests DIN VDE 0250-214

flame retardancyVDE 0472 ˜804/ —( IEC 332-

3/—and¬)

-corrosivity of combustiongases

pH - min 4.3;-max100 S/cm

VDE 0472˜813 (IEC 60754-1and 2)

-density of smoke gases VDE 0472˜816 (IEC 61034-1and2)

Cable construction

Construction According to VDE 0250-214

Conductor —u wires according toVDE 0295 (HD 383) cl.1 or 2(IEC 60228)

Insulation XLPE compound2XI1 (DIX8) to VDE 0276-604

Core according to VDE 0250identification and VDE 0293

Inner sheath halogen free compound

Sheath halogen free compound, flameretardant type LTS 1

Color grey RAL 7035

Color codingSingle core - black or yellow-greenDouble core - blue and brown or yellow-green and black

3 - core 4 - core 5 - core multiple cores

brownblackgreyor

yellow/green

bluebrown

bluebrownblackgreyor

yellow/greenbrownblackgrey

bluebrownblackgreyblack

oryellow/green

bluebrownblackgrey

black with numbermark on cores

orblack with numbermark on cores andyellow/green corein the outer cover

E L K A B E L

Page 160: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 160/430

159

L O W

V O L T A G E P O W

E R C A B L E S

H A L O G E N F R E E ,F L

A ME R E T A R D A N T

Cu conductors XLPE insulation LSF sheaths

Construction data

NHXMH-o/j 300/500 V

Number ofconductors andnominal cross

section

Thickness ofinsulation

Thickness ofinner

sheath

Thickness ofsheath

Cable diameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

N x mm2 mm mm mm min max kg/km kg/km

1x1,51x2,51x4,01x6,01x101x16

2x1,52x2,52x4,0

3x1,53x2,53x4,03x6,03x103x163x253x35

4x1,54x2,54x4,04x6,04x10

4x164x254x35

5x1,55x2,55x4,05x6,05x105x165x255x35

7x1,57x2,5

0,50,50,60,60,70,7

0,50,50,6

0,50,50,60,60,70,70,90,9

0,50,50,60,60,7

0,70,90,9

0,50,50,60,60,70,70,90,9

0,50,5

1,41,41,41,41,41,4

0,40,40,4

0,40,40,40,40,60,80,81,0

0,40,40,60,60,6

0,81,01,0

0,40,40,60,60,60,81,01,2

0,40,4

1,41,41,41,41,41,4

1,41,41,4

1,41,41,41,61,61,61,81,8

1,41,41,61,61,6

1,61,81,8

1,41,41,61,61,61,81,81,8

1,41,6

5,05,46,06,47,48,6

8,08,8

10,0

8,49,3

10,512,014,517,021,023,5

9,010,012,013,015,5

19,023,526,5

9,610,513,014,517,021,025,528,5

10,012,0

8,89,4

10,010,512,013,5

9,410,512,0

9,811,012,514,016,520,525,528,5

10,511,514,015,518,0

22,528,031,0

11,512,515,516,519,525,030,534,5

12,014,0

1429375594

149

284675

4370

112168282460728

1010

5793

149223376

6149701346

71116187279470767

12131683

100163

486179

112160230

108140205

131178239325503769

11641542

150211309242630

96914901935

178240380480730

114517982495

210302

E L K A B E L

Page 161: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 161/430

Technical data

160

Application

The power cables with retaimnent of insulation 180 min. flame retardant, with low halogen free smoke emission and cor-rosion at fire conditions are suitable for used in electrical installations for break-downsupply, signalization and controlin:

important objects - power stations (nuclear, thermal), transformer substations, metro, airportpublic buildings - hospitals, hotels, theaters, cinemas,public and commercial centers, places with great concentrationof people and material values whose safety in case of fire should be guaranteedThe cables are designed for fixed laying in dry and wet premises and outdoor, but not directly underground or in water.Laying in cable duct is allowed in case precautions are taken no water collection in the duct to be guaranteed.

L O W

V O L T A

G E P O W E R C A

B L E S

H

A L O G E N F R E E ,

F L A M E R E T A R D A N T

(N)HXH-FE 180 Uo/U - 0.6/1 kVDIN VDE 0266

Conductor resistance at20∞C

according to VDE 0295(IEC60228) cl.1 or 2

Operating temperature 90∞— continuous operation

Short circuit temperature 250∞— / 5 s max./

Nominal voltage Uo/U:Test voltage

0.6/1Í V ¿— - 4kV

Bending radius, min 15xD cable

Testsaccording to DIN VDE 0266part

3 and IEC 331

Retainment of insulationaccording to IEC 331

180 min

Temperature range -30 to +70∞C

Cable construction

Construction According to VDE 0266

Conductor —u wires according toVDE 0295 (HD 383) cl.1 or 2

(IEC 60228)

Insulation double layer insulation consisting of mica tape and cross-linked polymer according toVDE 0207 part 23 HI1

Inner sheath tapes or extruded layer

Sheath plastic compound, type HM4according to VDE 0207 part.24

Color orange

Color coding

Single core - black or yellow-greenDouble core - blue and brown or yellow-green and black

3 - core 4 - core 5 - core Multiple core

brown;black;greyor

yellow/green; blue;

brown

blue; brown;blackgrey;

oryellow/green;

brownblack; grey

blue;brown;blackgrey; black

oryellow/green;blue; brown;black; grey

black with numbermark on cores

orblack with numbermark on cores andyellow/green corein the outer cover

E L K A B E L

Page 162: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 162/430

161

L O W

V O L T A G E P O W

E R C A B L E S

H A L O G E N F R E E ,F L

A ME R E T A R D A N T

Cu conductors XLPE insulation LSF sheaths

Construction data

(N)HXH FE 180 0.6/1 kV

Number of conductorsand nominal cross section

Cable diameterapprox.

Mass ofCu

approx.

Mass of cable approx.

N ı mm2 mm kg/km kg/km

1x4,0re1x6,0re1x10re1x16re

2x1,5re2x2,5re2x4,0re2x6,0re2x10re

3x1,5re3x2,5re3x4,0re3x6,0re3x10re3x16rm3x25rm4x1,5re4x2,5re4x4,0re4x6,0re4x10re4x16rm4x25rm4x35rm

4x50rm

5x1,5re5x2,5re5x4,0re5x6,0re5x10re5x16rm

7x1,5re12x1,5re

375694

149

284675

112188

4370

1121682824607285793

149223376614970

1346

1817

71116187279470767

100171

105130170250

190220280340450

240290340450620850

1300280350440560760

110016001940

2570

330410520660950

1300

380580

89

1011

1213141516

151617182022261516171920222629

33

171920222427

1923

E L K A B E L

Page 163: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 163/430

Technical data

162

Application

The power cables flame retardant, with low halogen free smoke emission and corrosion at fire conditions are suitablefor use in electrical installations for nominal voltage 0.6/1kV in:important objects - power stations (nuclear, thermal), transformer substations, metro, airport, public buildings - hospi-

tals, hotels, theaters, cinemas, public and commercial centers, places with great concentration of people and materialvalues whose safety in case of fire should be guaranteed. The cables can be laid indoor, in air or in concrete. Directlaying underground or in water is not allowed.

L O W

V O L T A

G E P O W E R C A

B L E S

H

A L O G E N F R E E ,

F L A M E R E T A R D A N T

N2XH -0 / J Uo/U - 0.6/1 kV VDE 0276-604 (HD 604 S1)

Conductor resistance at20∞C

according to VDE 0295(IEC60228) cl.1 or 2

Operating temperature 90∞— continuous operationOverload temperature 130∞— /100h per year max/

Short circuit temperatureNominal voltage Uo/U

250∞— / 5 s max./.0.6/1 kV

Highest system voltage no more than 1.2 kV

Test voltage ¿C - 5 min between cores - 3.5 ÍV

Bending radius, min 6xD cable

Temperature of layingTemperature of exploita-tion

no less than 0∞—-30 to 50∞—

Tests-flame retardant

VDE 0276-604VDE 0472 p804/ —( IEC 332-3/— and ¬)

-corrosivity of combustiongases and conductivity VDE 0472p813 (IEC 60754-

pH - min 4.3; -max100S/cm

1and 2

-density of smoke gases VDE 0472p816 (IEC 61034-1and 2)

Cable construction

Construction According to VDE 0276-604

Conductor —u wires according toVDE 0295 (HD 383) cl.1 or 2(IEC 60228)

Insulation XLPE compound2XI1 (DIX8) to VDE 0276-604Core identification according toVDE 0276-604 and VDE 0293

Inner sheath halogen free compound

Sheath halogen free compound, flameretardant type LTS 1

Color black

Color coding

Single core - black or yellow/greenDouble core - brown ; blue or yellow/green; black

3 - core 4 - core 5 - core multiple core

brown,black grey

oryellow/green; blue ;

brown

blue; brown;black, grey

oryellow/green;brown;black;

grey

blue; brown;black; grey;

blackor

yellow/green;blue; brown;

black;

grey

black with numbermark on cores

orblack with numbermark on cores andyellow/green corein the outer cover

E L K A B E L

Page 164: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 164/430

163

L O W

V O L T A G E P O W

E R C A B L E S

H A L O G E N F R E E ,F L

A ME R E T A R D A N T

Cu conductors XLPE insulation LSF sheaths

Construction data

N2XH - 0/j 0.6/1 kV

Number ofconductors andnominal cross

section

Cablediameter

approx.

Mass ofcore

approx.

Mass ofcable

approx.

N ı mm2 mm kg/km kg/km

1x4,01x6,01x101x161x251x351x501x701x95

1x1201x150

1x1851x2401x300

2x1,52x2,52x4,02x6,02x102x162x253x1,53x2,53x4,03x6,0

3x103x163x253x353x503x703x95

3x1203x1503x1853x240

3x50/253x70/353x95/50

3x120/703x150/703x185/95

3x240/120

9,210,211,212,314,215,416,917,820,222,324,4

25,928,732,8

12,212,813,415,716,517,623,212,213,214,415,3

16,520,223,826,929,232,837,341,545,450,256,3

32,237,441,542,048,553,063,0

385897

153243337454656911

11471415

177023272887

284675

1121882984854370

112168

282447728

10101363196827323440424553116981

1680235232164128499262408064

143159212268379492624826

120215051705

220227483297

182215273342454597981205245332413

548794120516041805249533034048489551107805

2205294839084805574572109155

Construction data

N2XH - 0/j 0.6/1 kV

Number ofconductors andnominal cross

section

Cablediameter

approx.

Mass ofcore

approx.

Mass ofcable

approx.

N ı mm2 mm kg/km kg/km

4x1,54x2,54x4,04x6,04x104x164x254x354x504x704x95

4x1204x1504x1854x240

5x1,55x2,55x4,05x6,05x105x167x1,5

10x1,512x1,514x1,5

19x1,524x1,530x1,5

*16x1.57x2,5

10x2,512x2,514x2,519x2,524x2,530x2,5

7x4,012x4,0

13,214,215,416,517,619,526,229,232,437,340,6

44,850,553,061,8

14,215,216,517,519,322,414,216,218,519,5

21,322,423,817.715,218,219,520,421,624,527,3

17,221,5

5793

149223376595970

1346181726243643

4587566070829308

71116187279470744100142171199

270341426227163232279325441557697

261448

232295385485675934

14421903230532054204

430663557805

10295

275335453564786

1145315415458535

648762897591410545605672844

10481235

235815

E L K A B E L

Page 165: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 165/430

Cable construction

Construction according to DIN VDE 0276-622

Conductor —u and Al stranded compacted,wires according to IEC 60228 cl.2and VDE 0295 cl.2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- semi-conductive XLPE compoundconductive layer and semi-conductive tape

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Separating layer layer of plastic tape

Sheath halogen free compound, flameretardant type HM4to VDE 0276-622

Color black

Technical data

Conductor resistance at

20∞C

According to IEC60228 class 2

and VDE 0295 class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max/

Nominal voltage Uo/U: 6.35/11 kV

Highest system voltage

Uo/U, no more than

6/10 kV; 12/20 kV

12 kV; 24 kV

Test voltage Uo/U

AC (≈) - 5 min

DC (=) - 15 min

6/10 12/20 kV

21 kV; 42 kV

67 kV; 134 kV

Bending radius, min

Temperature of laying

15xD cable

no less than -5∞—

Temperature of exploitation

Tests

-30 to 50∞—

VDE 0276-622

-flame retardantVDE 0276-622(VDE 0472-804

method C) - IEC 332-3/B

-corrosivity ofcombustion

gases

- Õ min. 4.3

- conductivity χı. 100µS/cm

-density of smoke gasesVDE 0276-622 method to

VDE0472-816

164

Application

The single-core cables flame retardant with insulation of cross-linked polyethylene (XLPE) are designed for transfer anddistribution of electrical power with nominal voltage Uo/U 6/10; 12/20 kV and frequency 50 Hz. The cables are manu-factured with sheaths of halogen free flame retardant materials.They are suitable for use in distribution installations, electric power stations and substations for fixed indoor assemblyin cable ducts and conduits, over shelves and grilles.They should not be laid directly underground or in water.The cables with halogen free materials are with low halogen free smoke emission and corrosivity.The cables should not

be laid in or near nuclear stations.

N2XSHNA2XSH

Uo/U - 6/10,12/20kV VDE 0276-622

M I D D L E V O L T A

G E P O W E R C A

B L E S

H

A L O G E N F R E E ,

F L A M E R E T A R D A N T

E L K A B E L

Page 166: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 166/430

165

MI D D L E V O L T A G E P

O WE R C A B L E S

H A L O G E N F R E E ,F L

A ME R E T A R D A N T

Cu / Al conductors XLPE insulation Cu screen LSF sheath

Construction data N2XSH, NA2XSH 6/10; 12/20 kV

Number ofconductorsand nominal

cross section

Thickness of

insula-

tion

Thickness of

sheath

Nominalcross-section

of screen

Cable diameterapprox.

Mass of

Cuapprox

Mass of

cableapprox.

Mass of

Alapprox.

Mass of

Cuapprox.

Mass of

cableapprox.

N ı mm2 mm mm mm2 mm mm kg/km kg/km kg/km kg/km kg/km

6/10 kV

1x35ÍÏ/161x50ÍÏ/161x70ÍÏ/161x95ÍÏ/16

1x120ÍÏ/161x150ÍÏ/251x185ÍÏ/251x240ÍÏ/251x300ÍÏ/251x400ÍÏ/35

1x500ÍÏ/35

12/20 kV

1x35ÍÏ/161x50ÍÏ/161x70ÍÏ/161x95ÍÏ/16

1x120ÍÏ/161x150ÍÏ/251x185ÍÏ/251x240ÍÏ/251x300ÍÏ/251x400ÍÏ/351x500ÍÏ/35

3,43,43,43,43,43,43,43,43,43,4

3,4

5,55,55,55,55,55,55,55,55,55,55,5

2,52,52,52,52,52,52,52,52,52,5

2,5

2,52,52,52,52,52,52,52,52,52,52,5

16161616162525252535

35

1616161616252525253535

23242627293032343640

43

2728303133343639414447

28293132343537394145

48

3233353638394144464952

493604793

1033125515961930245429803836

4807

493604793

10331255159619302454298038364807

1145129715501854212825242922353641495117

6209

13721531179521102394279932083837446654786613

94127183254321394495649812

1043

1374

94127183254321394495649812

10431374

176176176176176265265265265363

363

176176176176176265265265265363363

922996117

1251137115871752199622452688

3192

11481230136215071636186220382298256230493543

N2XSH NA2XSH

min max

E L K A B E L

Page 167: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 167/430

Cable construction

Construction According to DIN VDE 0276-622

Conductor —u and Al stranded compactedwiresto IEC 60228 cl.2 andVDE 0295 cl.2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi- semi-conductive XLPE compoundconductive layer and semi-conductive tape

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm or Cu tapes laidwith overlap over each phase

Cable assembly three insulated and screenesdphases are twisted with fillings andtape supportPVC compound

Inner sheath halogen free compound, flameretardant

Sheath halogen free compound, flameretardant type HM4to VDE 0276-622

Color black

Technical data

166

Application

The three-core cables flame retardant with insulation of cross-linked polyethylene (XLPE) are designed for transfer anddistribution of electrical power with nominal voltage Uo/U 6/10; 12/20 kV and frequency 50 Hz. The cables are manu-factured with sheaths of halogen free flame retardant materials. They are suitable for use in distribution installations,

electric power stations and substations for fixed indoor assembly in cable ducts and conduits, over shelves and grilles.They should not be laid directly underground or in water. The cables with halogen free materials are with low halogenfree smoke emission and corrosivity.The cables should not be laid in or near nuclear stations.

N2XSEHNA2XSEH

Uo/U - 6/10,12/20kV VDE 0276-622

M I D D L E V O L

T A G E P O W E R C A B L E S - T H R E E

C O R E

H A L O G E N F R E E

, F L A M E R E T A R D A N T

Conductor resistance at

20∞C

According to IEC60228 class 2

and VDE 0295 class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max/

Nominal voltage Uo/U: 6.35/11 kV

Highest system voltage

Uo/U, no more than

6/10 kV; 12/20 kV

12 kV; 24 kV

Test voltage Uo/U

AC (≈) - 5 min

DC (=) - 15 min

6/10 12/20 kV

21 kV; 42 kV

67 kV; 134 kV

Bending radius, min

Temperature of laying

15xD cable

no less than -5∞—

Temperature of

exploitation

Tests

-30 to 50∞—

VDE 0276-622

-flame retardant VDE 0276-622(VDE 0472-804method C) - IEC 332-3/B

-corrosivity ofcombustion

gases

- Õ min. 4.3

- conductivity χı. 100µS/cm

-density of smoke gasesVDE 0276-622 method to

VDE0472-816

E L K A B E L

Page 168: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 168/430

167

Construction data N2XSEH, NA2XSEH 6/10 kV

Number ofconductors andnominal cross

section

Thicknessof

insulation

Thicknessof

sheath

Nominalcross-

section ofscreen

Cable diame-ter

approx.Mass of

Cuapprox

Mass ofcable

approx.

Mass of

Alapprox.

Mass of

cableapprox.

N x mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km6/10kV

3x35rm/163x50rm/163x70rm/163x95rm/16

3x120rm/163x150rm/253x185rm/253x240rm/253x300rm/25

3,43,43,43,43,43,43,43,43,4

2,52,52,52,52,52,52,52,52,5

161616161625252525

46,248,853,057,160,664,268,574,379,6

101013631968273234404245531169818661

3276383447845930692382179691

1196314294

298404584809

10231257157920712589

261929233470410346275379614473318526

N2XSEH NA2XSEH

MI D D

L E V O L T A G E P O WE R C A B L E S -T H R E E C O R E

H A L O

G E N F R E E ,F L A

ME R E T A R D A N

T

Cu / Al conductors XLPE insulation Cu screen LSF sheath

E L K A B E L

Page 169: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 169/430

168

L O W

V O L T A

G E P O W E R C A

B L E S

H

A L O G E N F R E E ,

F L A M E R E T A R D A N T

E L K A B E L

Uo/U - 0.6/1 kVBS 6724-1997

Technical data

Application

The power and control cables with insulation of cross-linked polyethylene (XLPE) type LSOH are flame retardant, with low halogenfree smoke emission and corrosion at fire conditions and are suitable for use in electrical installations for nominal voltage Uo/U 0.6/1kV. Cables are designed with sheath of halogen free materials, flame retardant, free smoke emission and corrosion, and non-mag-netic armor of ¿l wires. They are suitable for use in distribution networks, electrical power stations (NPP and TPP) and substations,

metro. These cables are for fixed assembly in lines with unlimited difference levels, for laying in industrial sites, indoor installations,in cable ducts, conduits and shafts, over shelves and grills and outdoor shelter.

Conductor resistance at

20∞C

According to BS 6360 (IEC228)

class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max/

Short circuit temperature

Nominal voltage Uo/U

250∞— / 5 s max./.

0.6/1 kVHighest system voltage 1.2 kV

Test voltage

¿C - 5 min

Between cores - 3.5 ÍV

Between core and armor- 3.5 ÍV

Bending radius, min 6xD cable

Temperature of layingTemperature of exploitation

no less than 0∞—-30 to 50∞—

Flame retardant According toBS 4066-3 categoryC (IEC 332-3 category —)

Force of strain in laying Nmax.

Cu cores - 50*n*S core

where: n is number of cores andS is nominal cross-section ofcores in mm

Cable construction

Construction According to BS 6724-97

Conductor —u or Al stranded compacted,wires according to BS 6360(IEC 228) cl.2

Insulation XLPE compoundColor 2-cores - red; black

3-cores - red; yellow; blue4-cores - red; yellow; blue; black5-cores - red; yellow; blue; blackControl - black with white numbers or white with blacknumbers

Inner sheath halogen free compound

Armour steel galvanized wires, laid concentrically

Sheath Halogen free compound, flameretardant type LTS 1

Color black

Cu /XLPE / LSF /SWA /LSF

Page 170: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 170/430

169

L O W

V O L T A G E P O W

E R C A B L E S

H A L O G E N F R E E ,F L

A ME R E T A R D A N T

Cu conductors XLPE insulation LSF sheath Armour st. wires LSF sheath

E L K A B E L

Construction data

Cu/XLPE/LSF/SWA/LSF 0.6/1 kV

Number ofconductors and

nominal crosssection

Thickness of

insulation

Diameter ofSt wires for

armour

Thickness of

sheath

Cable diameter

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N x mm2 mm mm mm kg/km kg/km

2x1.5rm2x2.5rm2x4.0rm2x6.0rm2x10rm2x16rm2x25rm2x35rm3x1.5rm3x2.5rm

3x4.0rm3x6.0rm3x10rm3x16rm3x25rm3x35rm4x1.5rm4x2.5rm4x4.0rm4x6.0rm4x10rm4x16rm4x25rm4x35rm4x35sm4x50sm4x70sm4x95sm

4x120sm4x150sm4x185sm5x1.5rm5x2.5rm5x4.0rm5x6.0rm5x10rm5x16rm5x25rm5x35rm7x1.5rm

12x1.5rm

19x1.5rm27x1.5rm37x1.5rm7x2.5rm

12x2.5rm19x2.5rm27x2.5rm37x2.5rm

0.60.70.70.70.70.70.90.90.60.7

0.70.70.70.70.90.90.60.70.70.70.70.70.90.90.91.01.11.11.21.41.60.60.70.70.70.70.70.90.90.60.6

0.60.60.60.70.70.70.70.7

0.90.90.90.90.9

1.251.251.60.90.9

0.90.91.251.251.61.60.90.90.9

1.251.251.251.61.61.61.62.02.02.52.52.50.90.90.9

1.251.251.601.601.600.9

1.25

1.251.61.60.9

1.251.61.61.6

1.31.41.41.41.51.51.61.71.31.4

1.41.41.51.61.71.81.31.41.41.51.51.61.71.81.81.92.12.22.42.62.61.41.41.51.51.61.71.81.91.41.5

1.61.71.71.41.61.71.81.8

12.112.914.715.918.021.926.729.212.814.1

15.818.021.223.128.230.813.315.016.418.721.123..428.933.728.632

37.741.747.151.456.614.316.319.020.925.828.433.536.615.218.5

21.126.729.017.122.426.630.733.8

284675

1101823034706524269

1101652754507009805592

146218363592925

13031303185726013540446055756880

69114182275455745

11651640

96165

260373506160525590621845

mm

283347411493647950

12821727300379

462555847

111115752113321415513737974

1277197224702324296142095374692682669988367473594850

1127166223492964421717

92213611629549946

141818242006

Page 171: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 171/430

Cu conductors XLPE insulation LSF sheath Armour Al. wires LSF sheath

170

L O W

V O L T A

G E P O W E R C A

B L E S

H

A L O G E N F R E E ,

F L A M E R E T A R D A N T

E L K A B E L

Uo/U - 0.6/1 kVBS 6724 - 1997

Technical data

Application

The single-core power cables with insulation of cross-linked polyethylene (XLPE) type LSOH are flame retardant, with low halogenfree smoke emission and corrosion at fire conditions and are suitable for use in electrical installations for nominal voltage Uo/U 0.6/1kV. Cables are designed with sheath, which do not contain halogen materials, flame retardant, free smoke emission and corrosion,and non-magnetic armor of ¿l wires. They are suitable for use in distribution networks, electrical power stations and substations.These cables are for fixed assembly in lines with unlimited difference levels, for laying in industrial sites, indoor installations, in cableducts, conduits and shafts, over shelves and grills and outdoor shelter.

Conductor resistance at20∞C

According toBS 6360 (IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max/

Short circuit temperature

Nominal voltage Uo/U

250∞— /5 s max./

Highest system voltageUo/U, no more than

0.6/1 kV1.2 kV

Test voltage ¿C - 5 min

Bending radius, minTemperature of laying

Between cores and armor -3.5kV

6x D cableno less than 0∞—

Temperature of exploitation -30 to 500—

Flame retardant According to BS 4066-3Category —(IEC 332-3 category —)

Force of strain in laying Nmax.

Cu cores -50*n*S coreWhere: n is number of cores and

S is nominal cross-sec-tion of cores in mm

Cable constructionConstruction According to BS 6724-1997

Conductor —u stranded circular and sector, according to BS 6360(IEC60228) cl. 2

Insulation Extruded XLPE compound

Color black or redInner sheath halogen free compound

Armour ¿l wires laid concentrically

Sheath halogen free compound,flame retardant type LTS 1

Color black

Cu/XLPE/LSF/AWA/LSF

Construction data

Cu/XLPE/LSF/AWA/LSF 0.6/1 kV

Number ofconductors andnominal cross

section

Thickness ofinsulation

Diameter of Al wires for

armour

Thickness ofsheath

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.N x mm2 mm mm mm kg/km kg/km

Uo/U0.6/1kV

1x150rm1x185rm1x240rm1x300rm

1x400rm1x500rm

1.41.61.71.8

2.02.2

1.61.61.61.6

2.02.0

1.71.81.81.9

2.02.1

26.328.731.434.1

38.942.8

1378170322082765

36804600

mm

1970237029603610

46005680

Cu /XLPE/LSF/AWA/LSF

Page 172: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 172/430

MI D D L E V O L T A G E P

O WE R C A B L E S

H A L O G E N F R E E ,F L

A ME R E T A R D A N T

171L K A B E L

Uo/U - 6.35/11 kVBS 7835 - 2000

Technical data

Application

The single-core power cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution of electri-cal power with nominal voltage Uo/U 6.35/11 kV and frequency 49 Hz to 61 H. Cables are designed with sheath of halogen free mate-

rials, flame retardant, free smoke emission and corrosion, and non-magnetic armor of ¿l wires. They are suitable for use in distribu-tion networks, electrical power stations and substations. These cables are for fixed assembly in lines with unlimited difference levelsfor indoor installations, in cable ducts, conduits and shafts, over shelves and grills and outdoor shelter.

Cable constructionConstruction According to BS 6622-1999

Conductor —u or Al stranded compacted,wires according to BS 6360(IEC 60228) class2

Inner semi- semi-conductive XLPE compoundconductive layer

Insulation XLPE compound

Outer semi- semi-conductive XLPE compoundconductive layer

Metal screen -I option - Cu tapes laid withoverlap-II option - Cu wires laid concentrically

Separating layer halogen free compound

Armour ¿l cores laid concentrically

Sheath halogen free fire retardantcompound type LTS 1

Color red, black

Cu/XLPE/CTS/LSF/AWA/LSF

Construction dataCu/XLPE/CTS/LSF/AWA/LSF 6.35/11 kV

Number ofconductors andnominal cross

section

Thickness ofinsulation

Diameter of Al wires for

armour

Thickness ofsheath

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.N x mm2 mm mm mm kg/km kg/km

Uo/U 6.35/11kV

1x50rm1x70rm1x95rm

1x120rm1x150rm1x185rm1x240rm

1x300rm1x400rm1x500rm

3.43.43.43.43.43.43.4

3.43.43.4

1.61.61.61.62.02.02.0

2.02.02.5

1.81.91.92.02.12.12.2

2.22.42.5

28.530.432.133.936.338.140.7

43.046.550.9

520720960

1200146517952325

292537504740

mm

1200155018502150265031003700

440052506800

Cu /XLPE/CTS/LSF/AWA/LSF

Cu conductors XLPE insulation Cu screen LSF sheath Armour Al wires LSF sheath

Conductor resistance at20∞C

According toBS 6360 (IEC228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./Short circuit temperature 250∞— /5 s max/Nominal voltage Uo/U: 6.35/11 kVHighest system voltage

Uo/U, no more than 12 kV;

Test voltage

AC (≈) - 15 minLevel of partial discharge at

12.5 kV

25.5 ÍVχı 10pC

Bending radius, minTemperature of laying

15xD cableno less than -5∞—

Temperature of exploitation -30 to 50∞—

Flame retardant

According to BS 4066-3

category —

(IEC 332-3 category —)

Force of strain in laying N

max.

Al cores- 30*n*S coreCu cores- 50*n*S corewhere: n is number of coresand S is cross-section of coresin mm

Page 173: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 173/430

172

L O W

V O L T A

G E P O W E R C A

B L E S

H

A L O G E N F R E E ,

F L A M E R E T A R D A N T

E L K A B E L

N2X—H Uo/U - 0.6/1 kV VDE 0276-604 (HD 604 S1)

Technical data

Application

The power cables flame retardant, with low halogen free smoke emission and corrosion at fire conditions are suitable for use in elec-trical installations for nominal voltage 0.6/1kV in:

important objects - power stations (nuclear, thermal), transformer substations, metro, airport,public buildings - hospitals, hotels, theaters, cinemas, public and commercial centers,

places with great concentration of people and material values whose safety in case of fire should be guaranteed.The cables can be laid indoor, in air or in concrete. Direct laying underground or in water is not allowed.

Conductor resistance at20∞C

according to VDE 0295(IEC60228) cl.1 or 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max/

Short circuit temperatureNominal voltage Uo/U

250∞— / 5 s max./.0.6/1 kV

Highest system voltage no more than 1.2 kV

Test voltage ¿C - 5 min between cores - 3.5 ÍV

Bending radius, min 6xD cable

Temperature of layingTemperature of exploitation

no less than 0∞—-30 to 50∞—

Tests-flame retardant

VDE 0276-604VDE 0472 p804/ —( IEC 332-3/—and ¬)

-corrosivity of combustiongases and conductivity

pH - min 4.3; -max100

S/cm VDE 0472p813 (IEC 60754-1 and 2)

-density of smoke gases VDE 0472p816 (IEC 61034-1 and 2)

Cable constructionConstruction According to VDE 0276-604

Conductor —u wires according toVDE 0295 (HD 383) cl.1 or 2(IEC 60228)

Insulation XLPE compound2XI1 (DIX8) to VDE 0276-604

Core according to VDE 0276-604identification and VDE 0293

Inner sheath halogen free compound

Concentric of plain round copper wiresConductor and one or two transverse

counter helix of copper tapes

Sheath halogen free compound,flame retardant type LTS 1

Color black

Color coding

Single core - black or yellow/greenDouble core - black ; blue or yellow/green; black

3- core 4 - core 5 - core multiple core

Black; blue;brown

oryellow/green;black; blue

black; blue;brown; black;

oryellow/green;black; blue

brown;

black; blue;brown; black;

blackor

yellow/green;black; blue ;brown; black;

black with numbermark on cores orblack with number

mark on coresand yellow/greencore in the outer

cover

Page 174: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 174/430

173

L O W

V O L T A G E P O W

E R C A B L E S

H A L O G E N F R E E ,F L

A ME R E T A R D A N T

Cu conductors XLPE insulation Cu concentric conductor LSF sheaths

E L K A B E L

Number of wires and nominalcross section Shape

Concentricconductor

cross section

Outer diameterof cableapprox.

Cu weight

Cable weightapprox.

N x mm2 mm2 mm kg/km kg/km

1x1,5 re 1,5 7,9 27 981x2,5 re 2,5 8,5 47 1221x4,0 re 4,0 9,4 74 1631x6,0 re 6,0 9,9 108 2031x10 re 10 11,3 182 2861x16 re 16 12,8 297 4101x25 rm 25 12,9 465 6061x35 rm 35 16,4 654 807

2x1,5 re 1,5 13,0 45 2302x2,5 re 2,5 13,7 68 2732x4,0 re 4,0 15,9 110 3752x6,0 re 6,0 17,1 164 458

2x10 re 10 19,1 274 6192x16 re 16 21,0 435 8412x25 rm 25 25,1 703 12762x35 rm 35 27,8 980 16422x50 rm 50 31,5 1343 2193

3x1,5 re 1,5 13,5 56 2523x2,5 re 2,5 14,3 90 3053x4,0 re 4,0 16,6 147 4253x6,0 re 6,0 17,7 243 5283x10 re 10 20,0 365 7243x16 re 16 22,1 580 9993x25 rm 16 27,8 855 14403x25 rm 25 26,6 938 15243x35 rm 16 29,1 1127 1813

3x35 rm 35 29,4 1317 19873x50 rm 25 32,7 1581 24153x35 sm 35 27,1 1339 16443x35 sm 16 26,6 1161 16273x50 sm 25 29,6 1593 21743x50 sm 50 30,6 1819 22603x70 sm 35 33,6 2265 29323x70 sm 70 34,1 2584 30973x95 sm 50 38,2 3151 40043x95 sm 95 39,4 3692 4336

3x120 sm 70 38,3 4038 49253x120 sm 120 41,6 4443 51243x150 sm 70 44,7 4827 58903x150 sm 150 45,8 5543 63523x185 sm 95 49,0 6051 73293x240 sm 120 54,5 7881 93994x1,5 re 1,5 14,3 70 2844x2,5 re 2,5 16,3 136 3824x4,0 re 4,0 17,8 183 4944x6,0 re 6,0 19,0 297 6204x10 re 10 21,5 457 8604x16 re 16 23,8 725 11964x25 rm 16 29,0 1090 17644x35 rm 16 32,0 1456 22464x50 rm 25 36,4 1998 30244x35 sm 16 29,8 1495 20604x50 sm 25 33,1 2044 27304x70 sm 35 38,4 2911 37584x95 sm 50 42,6 4041 5054

4x120 sm 70 43,1 5162 62464x150 sm 70 50,7 6214 7548

4x185 sm 95 55,3 7826 93744x240 sm 120 62,3 10150 12124

Page 175: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 175/430

Cable construction

Construction According to IEC 60502-1

Conductor Cu solid or stranded wires class 1

or 2 according to IEC 60228

Insulation XLPE compound

Identification color code acc.

of cores to VDE 0276-604

Inner sheath halogen free compound

Armour two steel tapes or two

galvanized steel tapes

Sheath halogen free compound, flame

retardant type HM4( LTS 1 )

Color black

Technical data

174

Application

The power cables flame retardant, with low halogen free smoke emission and corrosion at fire conditions are suitable for use inelectrical installations for nominal voltage 0.6/1kV in:

important objects - power stations (nuclear, thermal), transformer substations, metro, airport,public buildings - hospitals, hotels, theaters, cinemas, public and commercial centers,places with great concentration of people and material values whose safety in case of fire should be guaranteed.

The cables can be laid indoor, in air or in concrete.Direct laying underground or in water is not allowed.

L O W

V O L T A G E P O W E R C A

B L E S

H A L

O G E N F R E E , F L A M E R E T A R

D A N T

Color coding

Single core - black or yellow-greenDouble core - blue and brown or yellow-green and black

Uo/U - 0.6/1 kVIEC 60502-1 and VDE

0276-604 (HD 604 S1)XBH/¿2XBH

Conductor resistanceOperating temperature

According to IEC 6022890∞C

Overload temperature 130∞C/100h per yearShort circuit temperature 250∞C ( 5 sec.)

Nominal voltage 0.6/1 kV

Highest system voltage 1.2 kVTest voltage, AC 50 Hz 4.0 kV

Bending radiussingle core 15 x Dcablemulticore 15 x Dcable

Temperature of laying no less than 0∞—Temperature of

exploitation -30 to 70∞C

Tests-flame retardant

IEC 60502-1 and VDE 0276-604

VDE 0472 p804/ —( IEC 332-3/— and ¬)

-corrosivity of combustion

gases and conductivity

pH - min 4.3; σ-max100µS/cm VDE 0472p813 (IEC 60754-1and2

-density of smoke gasesVDE 0472p816 (IEC 61034-1and2)

3 - core 4 - core 5 - core Multiple core

brown;black; grey

oryellow/green; blue; brown

blue; brown;black; grey

oryellow/green

; brown;black ;grey

blue ; brown;black; grey

blackor

yellow/green; blue;brown;

black; grey

black with num-ber mark on

coresor

black with num-ber mark on

cores and yel-

low/green core inthe outer cover

E L K A B E L

Page 176: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 176/430

175

L OW

V OL T A GE P O

WE R C A B L E S

H A L

O GE N F R E E ,F L A ME R E T A R

D A N T

Cu / Al conductors XLPE insulation Armour-st. tapes LSF sheaths

Construction data 2XBH

Mass ofcable

approx.

Number ofconductors

and nominalcross section

Type ofcon-

ductors

Cablediameter

approx.

Massof

coreapprox.

N x mm2 mm2 mm kg/km

5x4,0 re 19,6 187 5905x6,0 re 21,0 279 7155x10 re 23,2 470 9555x16 re 25,7 744 12705x25 rm 31,7 1213 19255x35 rm 34,9 1683 24555x50 rm 40,1 2271 33905x70 rm 45,3 3280 44557x1,5 re 16,9 100 4208x1,5 re 18,2 114 485

10x1,5 re 19,9 142 57512x1,5 re 20,4 171 610

14x1,5 re 21,2 199 67516x1,5 re 22,1 227 72519x1,5 re 23,0 270 79520x1,5 re 24,0 284 85521x1,5 re 24,0 299 86524x1,5 re 26,1 341 100527x1,5 re 26,6 384 105530x1,5 re 27,5 426 112537x1,5 re 29,4 526 1300

7x2,5 re 18,0 163 5058x2,5 re 19,6 186 590

10x2,5 re 21,5 232 70512x2,5 re 22,0 279 76014x2,5 re 22,9 325 83016x2,5 re 23,9 372 905

19x2,5 re 25,0 441 100520x2,5 re 26,1 464 108021x2,5 re 26,1 488 109524x2,5 re 28,6 557 129027x2,5 re 29,2 627 136030x2,5 re 30,2 697 146537x2,5 re 32,3 859 1700

7x4,0 re 20,9 261 7008x4,0 re 22,9 299 825

10x4,0 re 25,4 373 10307x6,0 re 22,4 391 8858x6,0 re 19,5 447 1045

10x6,0 re 27,4 559 1270

Construction data A2XBH

Mass ofcable

approx.

Number ofconductors

and nominalcross section

Type ofcon-

ductors

Cablediameter

approx.

Massof

coreapprox.

N x mm2 mm2 mm2 mm kg/km

2x6,0 re 17,5 38 4052x10 re 19,1 56 4802x16 re 21,0 88 5802x25 rm 25,1 144 8152x35 rm 27,3 199 9602x50 rm 30,7 269 12003x6,0 re 18,3 56 4403x10 re 20,0 83 5253x16 re 22,1 132 6403x25 rm 26,6 216 9003x35 rm 29,1 298 10803x50 rm 32,8 404 1355

3x70 sm 33,0 584 13603x95 sm 38,0 809 19253x120 sm 40,0 1023 21853x150 sm 44,2 1257 26203x185 sm 47,9 1579 31153x240 sm 53,3 2071 38553x300 sm 58,7 2589 46203x6,0 + 4 re/re 19,2 68 4703x10 + 6 re/re 21,0 102 5603x16 + 10 re/re 23,2 160 6893x25 + 16 rm/rm 27,8 261 9653x35 + 16 rm/rm 30,1 343 11353x50 + 25 sm/rm 33,0 476 13053x70 + 35 sm/rm 38,2 684 18053x95 + 50 sm/rm 42,4 944 2235

3x120 + 70 sm/rm 45,6 1218 26203x150 + 70 sm/rm 50,2 1452 30803x185 + 95 sm/rm 54,5 1848 36803x240 + 120 sm/rm 60,9 2412 45603x300 + 150 sm/rm 66,7 3008 54654x6,0 re 19,6 75 5004x10 re 21,5 111 6054x16 re 23,8 176 7404x25 rm 29,0 288 10604x35 rm 31,9 398 12804x50 sm 33,0 539 13554x70 sm 38,2 779 19104x95 sm 42,4 1079 23804x120 sm 45,6 1364 27754x150 sm 50,2 1676 33254x185 sm 54,5 2106 39554x240 sm 60,9 2762 4940

E L K A B E L

Page 177: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 177/430

176

L O W

V O L T A

G E P O W E R C A

B L E S

H

A L O G E N F R E E ,

F L A M E R E T A R D A N T

E L K A B E L

Uo/U - 0.6/1 kVIEC 60 502-1 and

VDE 0276-604 (HD 604 S1)

Technical data

Application

The power cables flame retardant, with low halogen free smoke emission and corrosion at fire conditions are suitable for use in elec-trical installations for nominal voltage 0.6/1kV in:important objects - power stations (nuclear, thermal), transformer substations, metro, airport, public buildings - hospitals, hotels, the-

aters, cinemas, public and commercial centers, places with great concentration of people and material values whose safety in caseof fire should be guaranteed. The cables can be laid indoor, in air or in concrete. Direct laying underground or in water is notallowed

Conductor resistance at20∞C

according to VDE 0295(IEC60228) cl.1 or 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max/

Short circuit temperatureNominal voltage Uo/U

250∞— / 5 s max./.0.6/1 kV

Highest system voltage no more than 1.2 kV

Test voltage ¿C - 5 min between cores - 3.5 ÍV

Bending radius, min 6xD cable

Temperature of layingTemperature of exploitation

no less than 0∞—-30 to 50∞—

Tests-flame retardant-corrosivity of combustiongases and conductivity

IEC 60502-1 and VDE 0276-604VDE 0472 p804/ —( IEC 332-3/—and ¬)

pH - min 4.3; -max100 S/cm VDE 0472p813 (IEC 60754-1 and 2)

-density of smoke gases VDE 0472p816 (IEC 61034-1 and 2)

Cable constructionConstruction According to VDE 0276-604

Conductor —u wires according toIEC60228

Insulation XLPE compound2XI1 (DIX8) to VDE 0276-604

Core according to VDE 0276-604identification and VDE 0293

Inner sheath halogen free compound

Metal screen for 2XSsH - copper breidfor 2XSsH - copper tape

Sheath halogen free compound,flame retardant typeHM4(LTS 1)

Color Black

Color coding

Single core - black or yellow/green.Double core - black ; blue or yellow/green; black

3- core 4 - core 5 - core multiple core

Black; blue;brown

oryellow/green;black; blue

black; blue;brown; black;

oryellow/green;black; blue

brown ;

black; blue;brown; black;

blackor

yellow/green;black; blue ;brown; black;

Black with num-ber mark on cores

orblack with number

mark on coresand Y / G

core in the outer

cover

2XSsH/(N)2XSsH

2XSH/(N)2XSH

Page 178: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 178/430

MI D D L E V O L T A G E P

O WE R C A B L E S

H A L

O G E N F R E E ,F L

A ME R E T A R D A

N T

177L K A B E L

Uo/U - 6.35/11 kVStandart: BS 7835-2000

Technical data

Application

The three-core power cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution of electri-cal power with nominal voltage Uo/U 6.35/11 kV and frequency 49 Hz to 61 H in urban and district electrical networks and for electri-

cal supply of transformer substations, small and medium industrial plants. Cables are designed with sheath of halogen free materi-als, flame retardant, free smoke emission and corrosion. They are suitable for use in distribution networks, electrical power stationsand substations. These cables are for fixed assembly in lines with unlimited difference levels for indoor installations, in cableducts, conduits and shafts, over shelves and grills and outdoor shelter.

Cable constructionConstruction Accordlng to BS 6622-1999

Conductor Cu or Al stranded compacted,wires according to BS 6360(lEC 228) class 2

Inner semi- semi-conductive XLPEconductive layer compound

Insulation XLPE compound

Outer semi- semi-conductive XLPEconductive layer compound

Metal screen -I option - Cu tapesover each phase laid withoverlap-II option - Cu cores laidconcentrically

Cable assembly Three insulated and screenedphases are twisted withfillings and tape support

Separating layer halogen free compound

Armour steel galvanized wires laid con-centrically

Sheath halogen free fire retardantcompound type LIS 1

Color red, black

Cu/XLPE/CTS/LSF/SWA/LSF

Construction data

Cu/XLPE/CTS/LSF/SWA/LSF 6.35/11 kV

Number ofconductors andnominal cross

section

Thickness ofinsulation

Diameter ofSt wires for

armour

Thickness ofsheath

Cable diameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.N x mm2 mm mm mm kg/km kg/km

UoUkxrmxrm

xrmxrmxrmxrm

mm

Cu /XLPE/CTS/LSF/AWA/LSF

Cu conductors* XLPE insulation Cu screen LSF sheath Armour st. wires LSF sheath

Conductor resistance at20∞C

According toBS 6360 (IEC228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max/

Nominal voltage Uo/U: 6.35/11 kV

Highest system voltage

Uo/U, no more than

12 kV;

Test voltage AC (≈) - 15 min

Level of partial discharge at12.5 kV

25.5 ÍV

χı 10pC

Bending radius, minTemperature of laying

15xD cableno less than 0∞—

Temperature of exploitation -30 to 50∞—

Flame retardant

According to BS 4066-3

category —

(IEC 332-3 category —)

Force of strain in laying Nmax.

Al cores- 30*n*S coreCu cores- 50*n*S core

where: n is number of coresand S is cross-section of coresin mm

Page 179: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 179/430

E L K A B E L

C O M

M U N I C A T I O N C A B L E S F O R

L O N G D I S T A N C E S

Page 180: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 180/430

E L K A B E L

C O M

M U N I C A T I O N C A B L E S

F O R

L O N G D I S T A N C E S

Page 181: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 181/430

Cable construction

Conductor bare copper conductor diameter0.9 mm and 1.2mm

Insulation insulation of paper string over

which is laid a paper tapeQuad each 4 wires are twisted to a quadCable core the quads are stranded into layers

Wrapping of paper tapesSheath of lead to which is added

antimony of 0.4 up to 0.6%

Technical data

Color coding

180

Application

These cables are used for construction of trunk cable communication networks and for connecting lines between dis-trict telephone exchanges.They are suitable for fixed underground installation in collectors, cable ducts and conduit.The use of these cables for power installations is not permitted.

C O M M U N I C A T

I O N C A B L E S F O

R L O N G D I S T A

N C E S

E L K A B E L

¿-PMZ . . . x4x0 .9 ST I LG

A -PMZ . . . x4x1 .2 ST I LG

similar to VDE 0816 part 3.

Side circuit - 1 Side circuit - 2

a - wire b - wire a - wire b - wire

white red green blue

The quads are supported with textile thread.In each

layer there are two adjacent quads - the one with red

color of the supporting spiral - showing the start of

counting and the other - with yellow colour - showing the

direction of counting.

Conductor diameter 0.9 1.2mm

Cond. resistance at 20oC- max. 28.3 15.85Ω/km

Insulation resistance -min. 12 000 MΩ.km

Mutual capacitance at800Hz-nom. 34 35nF/km

Capacitance unbalance at800Hz:

K1 - max.K2-3- max.

K9-12- max.E1-2 - max.

280 pF/425m700 pF/425m210 pF/425m700 pF/425m

Test voltage 50Hz, 2 min.wire - wire

wire - screen700 1000V

2000V

Operating voltage peak value 225V

Temperature rangemobile

fixed

0∞C ‰Ó +45∞C-30∞C ‰Ó +50∞C

Minimum bending radiusapprox.

13 ı cablediameter

Type codes ¿- outdoor cableP paper insulationMZ lead sheath with added hardenerSTI star quads in telecommunication cables for long

distances without phantom useLG layer stranding

Page 182: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 182/430

181

C O M

M U N I C A T I O N C A B L E S F O R L O

N G D I S T A N C E S

E L K A B E L

Cable core construction

Numberof

quads

Number of quads in centre and successive layers

First layer Second layer Third layer Fourth layer Fifth layer Sixth layer

Construction data A-PMZ ...x4x0.9 STI LG

Numberof quads

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Construction data A-PMZ ...x4x1.2 STI LG

Numberof quads

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km3471214192427303744526175

80102114

Paper insulation quads stranded in layers lead sheath.

10.912.015.018.819.822.425.426.828.030.433.836.539.143.4

44.750.053.3

751001753003504745996747499241118132115501905

203225912896

54759682912071311161619612182233026663387377243895163

537367197299

3471214192427303744526175

80102114

13.214.218.023.124.327.431.332.533.837.342.043.646.952.3

55.762.566.1

13317731053162084110631196132916391983234327493379

360545965137

695

787

1165

1739

1896

2361

2961

3172

3473

4105

5058

5835

6469

7948

828810311

11160

3

4

7

12

14

19

24

27

30

37

44

52

61

75

80

102

114

3

4

1

3

4

1

2

3

4

1

2

4

1

3

4

2

4

6

9

10

6

8

9

10

6

8

10

6

910

8

10

12

14

15

16

12

14

16

12

1516

14

16

18

20

22

18

2122

20

22

24

2728

26

28

32

34

Page 183: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 183/430

Cable construction

Conductor bare copper conductor diameter0.9 mm and 1.2mm

Insulation insulation of paper string overwhich is laid a paper tape

Quad each 4 wires are twisted to a quadCable core the quads are stranded into layers

Wrapping of paper tapesSheath of lead to which is added

antimony of 0.4 up to 0.6%Bedding of bitumen and impregnated cable

paper Armour of two steel tapesProtective of bitumen, synthetic yarn andcovering chalk

Technical data

Color coding

182

Application

These cables are used for construction of trunk cable communication networks and for connecting lines between dis-trict telephone exchanges.They are suitable for installation in ditches, at not big stretch strength and slope of the ground less than 45o.The use of these cables for power installations is not permitted.

C O M M U N I C A T

I O N C A B L E S F O

R L O N G D I S T A

N C E S

E L K A B E L

¿-PMZBC . . . x4x0 .9 ST I LG

A -PMZB C . . . x4x1 .2 ST I LG

similar to VDE 0816 part 3.

Conductor diameter 0.9 1.2mm

Cond. resistance at 20∞C -max. 28.3 15.85Ω/km

Insulation resistance -min. 12 000 MΩ.km

Mutual capacitance at800Hz-nom. 34 35nF/km

Capacitance unbalance at800Hz:

K1 - maxK2-3- max

K9-12- maxE1-2 - max

280 pF/425m700 pF/425m210 pF/425m700 pF/425m

Test voltage 50Hz, 2 min

wire - wire

wire - screen700 1000V

2000V

Operating voltage peak value 225V

Temperature range

mobilefixed

0∞C ‰Ó +45∞C-30∞C ‰Ó +50∞C

Minimum bending radiusapprox.

13 ı cablediameter

Type codes ¿- outdoor cableP paper insulationMZ lead sheath with added hardenerB armour— protective covering of bitumen and yarnSTI star quads in telecommunication cables for long

distances without phantom useLG layer stranding

Side circuit - 1 Side circuit - 2

a - wire b - wire a - wire b - wire

white red green blue

The quads are supported with textile thread.In each

layer there are two adjacent quads - the one with red

color of the supporting spiral - showing the start of

counting and the other - with yellow colour - showing the

direction of counting.

Page 184: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 184/430

183

C O M

M U N I C A T I O N C A B L E S F O R L O

N G D I S T A N C E S

E L K A B E L

Construction data ¿-PMZBC...x4x0.9 STI LG

Numberof quads

Externaldiameterapprox.

Copper weight

Cable weightapprox

mm kg/km kg/km

Construction data A-PMZBC...x4x1.2 STI LG

Numberof quads

Externaldiameterapprox.

Copper weight

Cable weightapprox

mm kg/km kg/km

347121419242730374452617580

102114

Paper insulation quads stranded in layers lead sheath armoured

19.120.223.227.728.731.134.135.536.738.942.445.047.651.853.0

58.563.0

7610217830635748461268876594311211325155519112039

26002905

8129091188176018882232261728283002340540204528507459086286

76959121

347121419242730374452617580

102114

21.422.426.931.833.036.139.941.142.445.850.452.055.462.065.3

72.175.7

136181317544634861108712231359167619932356276333983624

46215165

1019

1132

1698

2345

2528

3019

3650

3883

4195

4876

5783

6294

7298

9378

10161

1234613746

Cable core construction

Numberof

quads

Number of quads in centre and successive layers

First layer Second layer Third layer Fourth layer Fifth layer Sixth layer

3

4

7

12

14

19

24

27

30

37

44

52

61

75

80

102

114

3

4

1

3

4

1

2

3

4

1

2

4

1

3

4

2

4

6

9

10

6

8

9

10

6

8

10

6

9

10

8

10

12

14

15

16

12

14

16

12

15

16

14

16

18

20

22

18

21

22

20

22

24

27

28

26

28

32

34

Page 185: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 185/430

Technical data

Color coding

Type codes A- outdoor cable2Y polyethylene (PE) insulationF filled cable core(L)2Y laminated sheathStIII star quad in local cablesBd unit type stranding

Application

These cables are used as connecting cables in local networks and in PABX's for telephone purposes and for the trans-mission of signals. The filling of petro jelly does not permit moisture penetration into the cable core.

They are suitable for underground installation, in cable ducts and conduit, as well as for interior installations.The use of these cables for power installations is not permitted.These cables may only be used in locations with fire and explosion hazards in conjunction with the appropriate safetyprecautions.

C

O M M U N I C A T I O

N C A B L E S F O R

L O C A L N E T W O

R K S

E L K A B E L

A-2YF (L )2Y . . . x2x0 .4 S t I I I Bd

A-2YF (L )2Y . . . x2x0 .5 S t I I I Bd

A-2YF (L )2Y . . . x2x0 .6 S t I I I Bd

A-2YF (L )2Y . . . x2x0 .7 S t I I I Bd

similar to VDE 0816/part 1

184

Cable construction

Conductor Bare copper conductor diameter0.4 mm , 0.5mm, 0.6mm, 0.7mm

Insulation Polyethylene insulation type 2YI2according to VDE 0207 part 2.

Quad each 4 wires are twisted to a quad

Units 5 quads laid up to a basic unitCable core the units are stranded into acompact cable

Filing petroleum - based jelly Wrapping minimum of 1 layer of paper tape.Screen of aluminum tape , thickness

0.2mm, coated with copolymer onboth sides

Sheath of PE compound, low densitywith 2.5% carbon black

Conductor diameter 0.4 0.5mm

Conductor resistance at 20∞C-max 150 95Ω/km

Conductor diameter 0.6 0.7mm

Conductor resistance at 20∞C-max. 65 49Ω/km

Insulation resistance min. 5GΩ

.kmMutual capacitance at 800Hz-max. 55nF/km

Capacitance unbalances at 800Hz:K1 100% of all values

95% of all valuesK9-K12 100% of all values

90% of all values

980pF/500m420pF/500m800pF/500m

200pF/m

Test voltage 50Hz, 2 min.wire-wire

wire - screen500V2000V

Operating voltage peak value

cables with cores 0.4 and 0.5mmcables with cores 0.6 and 0.7mm

150V220V

Temperature rangemobile

fixed-10∞C ‰Ó +60∞C-40∞C ‰Ó +60∞C

Minimum bending radius approx.10 x cablediameter

Number ofquad

Side-circuit -1 Side-circuit -2

a-wire b-wire a-wire b-wire

1 white red green blue

2 yellow red green blue

3 gray red green blue

4 brown red green blue

5 black red green blue

Page 186: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 186/430

185

C O M

M U N I C A T I O N C A B L E S F O R L O

C A L N E T W O R K

S

PE insulation unit stranding jelly filling laminated sheath.

E L K A B E L

Construction data A-2YF(L)2Y

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0.4 St III Bd6 8.6 15 77

10 9.3 24 9920 11.7 49 15930 12.9 73 22250 16.2 126 33670 18.0 174 449

100 21.7 252 604150 25.7 380 867200 30.6 504 1124

x2x0.5 St III Bd6 9.2 23 98

10 10.5 37 12920 12.9 75 22330 15.4 113 30650 19.9 196 48070 22.0 271 632

100 25.2 392 864150 30.8 592 1264200 36.5 784 1630

x2x0.6 St III Bd6 10.4 32 122

10 12.2 54 16520 16.2 108 29230 18.0 163 40250 22.9 282 63870 26.5 390 851

100 30.4 564 1187x2x0.7 St III Bd

6 11.4 44 14910 13.5 72 21020 17.8 148 36230 21.7 222 522

50 27.0 384 81670 30.6 532 1087100 36.1 768 1527

Cable core construction

Numberof

pairs

Numberof

quads

Number of units

5ı4 25ı4

1-st layer 2-nd layer

6 3 3-quads.10 5 120 10 230 15 350 25 5 170 35 1 6

100 50 3 7150 75 3200 100 4

Page 187: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 187/430

Technical data

Color coding

Application

These cables are used as connecting cables in local networks and in PABX's for telephone purposes and for the trans-

mission of signals.They are suitable for underground installation, in cable ducts and conduit, as well as for interior installations.The use of these cables for power installations is not permitted.These cables may only be used in locations with fire and explosion hazards in conjunction with the appropriate safetyprecautions.

C

O M M U N I C A T I O

N C A B L E S F O R

L O C A L N E T W O

R K S

A-2Y(L )2Y . . . x2x0 .4 S t I I I Bd

A-2Y(L )2Y . . . x2x0 .5 S t I I I Bd

A-2Y(L )2Y . . . x2x0 .6 S t I I I Bd

A-2Y(L )2Y . . . x2x0 .7 S t I I I Bd

similar to VDE 0816/part 1

Cable construction

Conductor Bare copper conductor diameter0.4 mm , 0.5mm, 0.6mm, 0.7mm

Insulation PE low densityQuad 4 wires are twisted into a quadUnits 5 quads laid up to a basic unit

Cable core the units are stranded into acompact cable

Unit in each layer there is a unit withmarking red supporting spiral from which

the counting starts and a unitshowing the direction of counting -with yellow supporting spiral

Wrapping several layers of plastic tapesScreen of aluminum tape , thickness

not less than 0.04mm, one side coated with copolymer and 1 tinned copper wire with diameter 0.5mmunder the metal foil.

Sheath of PE compound low density with2.5% carbon black

Conductor diameter 0.4 0.5mm

Conductor resistance at 20∞C-max 150 95Ω/km

Conductor diameter 0.6 0.7mm

Conductor resistance at 20∞C-max. 65 49Ω/km

Insulation resistance min. 10 GΩ.kmMutual capacitance at 800Hz-max. 48 nF/km

Capacitance unbalances at 800Hz:K1 100% of all values

95% of all valuesK9-K12 100% of all values

90% of all values

980pF/500m420pF/500m800pF/500m

200pF/m

Test voltage 50Hz, 2 min.wire-wire

wire - screen500V2000V

Operating voltage peak value

cables with cores 0.4 and 0.5mmcables with cores 0.6 and 0.7mm

150V220V

Temperature rangemobile

fixed-10∞C ‰Ó +60∞C-40∞C ‰Ó +60∞C

Minimum bending radius approx. 10 x cablediameter

Number ofquad

Side-circuit -1 Side-circuit -2

a-wire b-wire a-wire b-wire

1 white red green blue

2 yellow red green blue

3 gray red green blue

4 brown red green blue

5 black red green blue

E L K A B E L186

Type codes A- outdoor cable2Y polyethylene (PE) insulation(L)2Y laminated sheathStIII star quad in local cablesBd unit type stranding

Page 188: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 188/430

C O M

M U N I C A T I O N C A B L E S F O R L O

C A L N E T W O R K

S

PE insulation unit stranding laminated sheath.

Cable core construction

Numberof

pairs

Numberof

quads

Number of units

5ı4 25ı4 50x4

1-st layer 2-nd layer 1-st layer 2-nd layer 1-st layer 2-nd layer

6 3 3-quads.10 5 120 10 230 15 350 25 570 35 1 6

100 50 3 7150 75 3200 100 4250 125 5300 150 1 5400 200 4500 250 5600 300 1 5700 350 1 6

800 400 1 71000 500 3 71200 600 4 8

Construction data A-2Y(L)2Y...

Numberof pairs

Externaldiameterapprox

Copper weight

Cable weightapprox

mm kg/km kg/km

x2x0.4 St III Bd6 7.4 17 51

10 8.5 27 7320 10.7 51 11730 12.4 74 157

50 15.3 127 24970 17.4 174 324

100 20.5 250 452150 24.7 374 642200 26.5 494 811250 30.4 613 1002300 31.7 738 1177400 37.1 983 1524500 40.4 1235 1902600 44.4 1476 2252700 47.6 1722 2621800 51.0 1968 2993

1000 56.6 2454 37031200 61.8 2941 4413

x2x0.5 St III Bd6 8.7 26 71

10 9.6 40 9720 11.7 78 15130 13.9 115 21550 16.9 196 33270 19.1 269 449

100 22.5 387 613150 27.0 580 880200 29.9 766 1141250 33.7 952 1389300 36.9 1146 1640400 40.4 1526 2161500 45.6 1918 2718600 49.3 2292 3197700 52.2 2674 3720800 64.0 3056 4247

1000 65.0 3813 52581200 69.1 4570 6271

Construction data A-2Y(L)2Y...

Numberof pairs

Externaldiameterapprox

Copper weight

Cable weightapprox

mm kg/km kg/km

x2x0.6 St III Bd6 9.3 36 86

10 10.5 57 12020 13.2 111 21230 15.4 164 291

50 20.1 281 46970 22.5 387 619

100 26.7 557 852150 32.9 834 1252200 35.9 1102 1601250 40.5 1371 1980300 43.9 1650 2342400 50.1 2197 3094500 54.7 2761 3913600 60.6 3300 4607700 64.7 3851 5357800 69.2 4401 6111

1000 76.8 5491 7565x2x0.7 St III Bd6

6 10.1 48 10710 11.8 77 15220 16.1 150 27730 18.7 222 39050 22.7 381 61470 25.6 526 816

100 31.7 757 1150150 38.1 1134 1665200 42.0 1500 2165250 47.1 1865 2676300 51.3 2245 3222400 52.7 2990 4239500 66.0 3757 5286600 71.9 4491 6274700 76.3 5240 7297

187L K A B E L

Page 189: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 189/430

Cable construction Technical data

Color coding

Type codesJ- installation cable

Y insulation or sheath of PVC(St) static screen

Lg laid up in layers

188 E L K A B E L

J -Y (S t )Y . . . x2x0 .6 Lg

J -Y (S t )Y . . . x2x0 .8 Lg

according to VDE 0815

Application

These cables are used for installation of equipment of telephone stations.They are suitable for fixed indoor installation and for external walls of buildings.The screen of metal foil protects the cable from external electrical interferences.The use of these cables for power installations and underground installation is not permitted.

I N S T A L L A T I O N C A B L E S F O R T E L E C O M M

U N I C A T I O N S S Y S T E M S

Conductor bare copper conductor diameter0.6 mm and 0.8mm

Insulation PVC insulation type YI1 accordingto VDE 0207 part 4.

Pairs each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping several layers of plastic tapesScreen of aluminum tape one side coated

with polyester and 1 tinned copperwire with diameter : 0.4mm for cablesup to 10 pairs 0.6mm for cablesexceeding 10 pairs

Sheath of PVC compound type YM1according to VDE 0207 part 5, greycolor according to RAL 7032

Number of pairs. The pairs are counted succes-sively commencing at the outside and countinginwards in the same manner throught all layers

Colorsb-wire

1 6 11 16 21 26 31 36 41 462 7 12 17 22 27 32 37 42 473 8 13 18 23 28 33 38 43 484 9 14 19 24 29 34 39 44 495 10 15 20 25 30 35 40 45 50

blueyellowgreenbrownblack

51 56 61 66 71 76 81 86 91 9652 57 62 67 72 77 82 87 92 9753 58 63 68 73 78 83 88 93 9854 59 64 69 74 79 84 89 94 9955 60 65 70 75 80 85 90 95 100

blueyellowgreenbrownblack

Identification of the a-wire for the first pair(counting pair) is red in each layer , and white

for all other pairs .

Conductor diameter 0.6 0.8mm

Cond. resistance of the loopat 20∞C - max.

130 73.2Ω

Insulation resistance min. 100MΩ.km

Mutual capacitance at800Hz-max.

100nF/km

Capacitance unbalances at800Hz

K1- max.300pF/100m

Test voltage 50Hz, 1 min.wire - wire

wire - screen800V800V

Operating voltage peak value 300V

Temperature rangemobilefixed

-5∞C ‰Ó+50∞C-30∞C ‰Ó+70∞C

Minimum bending radiusapprox.

7.5 x cablediameter

Page 190: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 190/430

189

I N S T

A L L A T I O N C A B L E S F O R T E L E C O MM U N I C A T I O N S

S Y S T E M S

E L K A B E L

PVC insulation pairs stranded in layers static screen sheath of PVC.

Cable core construction

Numberof pairs

Number of pairs in centre and successive layers

1 2 3 4 5 6

2 23 34 45 56 68 1 7

10 2 812 3 915 5 1016 5 1120 1 6 1324 2 8 1430 4 10 16

40 1 7 13 1950 4 10 15 21

100 2 8 14 20 25 31

Construction data J-Y (St) Y

Numberof pairs

Externaldiameterapprox

Copper weight

Cable weightapprox.

mm kg/km kg/km

Construction data J-Y (St) Y

Numberof pairs

Externaldiameterapprox

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0,6 Lg2 5,0 12 433 6,2 17 524 6,7 23 576 7,7 33 858 8,1 44 9710 9,0 55 11612 9,3 67 12616 10,4 88 16820 10,9 109 19824 12,1 131 22930 13,7 163 29140 15,3 216 36850 16,4 269 460100 22,9 536 819

x2x0,8 Lg2 6,4 20 693 8,4 30 864 9,1 39 986 10,7 58 1538 11,4 77 17210 12,8 96 22212 13,8 117 25416 15,5 154 32320 16,9 192 38624 18,7 230 46430 20,5 287 56640 23,6 382 72050 25,9 477 906100 35,9 951 1689

Page 191: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 191/430

190 E L K A B E L

Cable construction Technical data

Color coding

Type codesLi - stranded wire conductor

Y - insulation or sheath of PVC

L iYY . . . x0 .25mm 2 / 900V ; L iYY . . . x0 .75mm 2 / 900V

L iYY . . . x0 .34mm 2 / 900V ; L iYY . . . x1 .00mm 2 / 900V

L iYY . . . x0 .50mm 2 / 900V L iYY . . . x1 .50mm 2 / 900V

According to VDE 0812

Application

These non-screened flexible control and interconnecting cables are used in instrumentation and control engineeringwhere low current consumptions are required, e.g. in industrial electronics, information and transmission systems,office machines and precision mechanics.These cables are ideal for voice communication in telecommunications systems.These cables are also suitable for flexible and permanent installation for unimpeded movement, without tensile loadand without forced movement in dry rooms

F L E X I B L E C A B L E S F O R I N D U S T

R I A L E L E C T R O

N I C S

Conductor plain Cu wires, flexibleConstruction 0.25mm2 = 14x0.15mmof conductor 0.34mm2 = 7x0.25mm

0.50mm2 = 16x0.2mm0.75mm2 = 24x0.2mm1.00mm2 = 32x0.2mm1.50mm2 = 30x0.25mm

Insulation PVC insulation type YI2 according toVDE 0207,part 4

Core color coded according to DIN 47 100identification Type of lay-up cores laid up in

layers of optimum pitch Wrapping plastic foil overlappingSheath of PVC compound type

YM1 according to VDE0207 part 5

Sheath color gray, RAL 7032

Number ofwires

colorNumber of

wirescolor

1 white 6 pink

2 brown 7 blue

3 green 8 red

4 yellow 9 black

5 gray 10 violet

Cross section - mm2 0.250.340.50 0.751.0 1.5

Cond. resistance at 20∞C -max. Ω/km:Capacitance (core/core)pF/m

78

120

57

120

39

150

25.5

150

19.1

150

13

150

Mutual capacitance at800Hz-max. : 150pF/m

Insulation resistance min. 200 ΩM .km

Test voltage 50Hz, 1 min. 2500V

Operating voltage peak value 900V

Temperature range

mobile

fixed

-5∞C ‰Ó +50∞C

-30∞C ‰Ó +70∞C

Minimum bending radius 10 x cable diameter

Page 192: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 192/430

191

PVC insulation wires stranded in layers sheath of PVC.

Construction data LiYY...

Number

of wires

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

Construction data LiYY...

Number

of wires

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

x0,25 mm2/ 900V2 3,7 4,6 16,03 3,9 7,0 20,04 4,2 9,3 25,05 4,6 11,8 30,06 4,9 14,0 35,07 4,9 16,5 39,08 5,4 19,0 45,09 5,7 21,0 48,010 6,2 23,5 53,0

x0,34 mm2/ 900V

2 3,9 6,5 19,03 4,1 9,8 25,04 4,4 13,1 30,05 4,8 16,3 35,06 5,2 20,0 42,07 5,2 23,0 47,08 5,7 26,1 53,09 6,0 30,0 57,010 6,6 32,6 65,0

x0,50 mm2/ 900V2 4,7 8,8 26,03 4,9 13,2 35,04 5,4 18,0 42,05 5,9 22,0 50,06 6,4 26,0 58,0

7 6,4 32,0 65,08 7,1 36,0 75,09 7,5 40,0 82,010 8,2 45,0 90,0

x0,75 mm2/ 900V2 5,1 14,3 323 5,3 22,0 434 5,8 28,5 545 6,4 35,5 666 7,0 42,5 777 7,0 50,0 888 7,8 57,0 999 8,2 64,0 11010 10,0 71,0 135

x1,0 mm2/ 900V

2 5,4 19,0 393 5,7 28,5 524 6,3 38,0 665 6,9 47,5 806 7,5 56,0 957 7,5 66,0 1078 8,4 75,8 1229 9,8 85,0 15810 10,6 95,0 175

x1,5 mm2/ 900V2 6,4 28,0 533 6,7 42,0 734 7,4 55,0 935 8,2 69,1 1146 10,0 83,0 158

7 10,0 97,0 1768 11,0 111,0 2009 11,5 125,0 22110 12,6 139,0 245

E L K A B E L

F L E X I B L E C A B L E S F O R I N D U S T R I A L

E L E C T R O N I C S

Page 193: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 193/430

192

L iYY . . . x0 .50mm 2 / 1500VL iYY . . . x0 .75mm 2 / 1500V

according to VDE 0812

PVC insulation wires stranded in layers sheath of PVC.

Cable construction Technical data

Color coding

Application

These non-screened flexible control and interconnecting cables are used in instrumentation and control engineering

where low current consumptions are required, e.g. in industrial electronics, information and transmission systems,office machines and precision mechanics. These cables are ideal for voice communication in telecommunications sys-tems. These cables are also suitable for flexible and permanent installation for unimpeded movement, without tensileload and without forced movement in dry rooms

F L E X I B L E C A B L E S F O R I N D U S T

R I A L E L E C T R O

N I C S

Type codesLi - stranded wire conductor

Y - insulation or sheath of PVC

Construction data LiYY...

Numberof wires

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Construction data LiYY...

Numberof wires

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x0,50 mm2/1500 V2 5,5 8,8 313 5,8 13,0 404 6,3 17,4 505 7,0 22,0 606 7,6 26,0 707 7,6 30,5 798 8,5 35,0 909 9,9 39,0 12310 10,8 43,4 136

x0,75 mm2/ 1500 V2 6,3 14,2 423 6,6 21,2 564 7,3 28,3 705 8,0 35,3 856 9,8 42,4 1237 9,8 50,0 1368 10,8 56,0 1549 11,3 64,0 17010 12,4 71,0 188

Conductor plain Cu wires, flexibleConstruction 0.50mm2 = 16x0.2of conductor 0.75mm2 = 24x0.2Insulation PVC insulation type YI2 according to

VDE 0207, part 4Core color coded according to DIN 47 100identificationType of lay-up cores laid up in layers of optimum

pitch Wrapping plastic foil overlappingSheath of PVC compound type

YM1 according to VDE0207 part 5

Sheath color gray, RAL 7032

Cross section - mm2 0.50 0.75Cond. resistance at 20∞C -max. Ω/km:Capacitance, pF/mcore/core:

39.0

120

25.5

120

Mutual capacitance at800Hz-max. :

150pF/m

Insulation resistance min. 200 ΩM .km

Test voltage 50Hz, 1 min. 3000V

Operating voltage peak value 1500V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radius 10 x cable diameter

E L K A B E L

Number ofwires

colorNumber of

wirescolor

1 white 6 pink2 brown 7 blue3 green 8 red4 yellow 9 black

5 gray 10 violet

Page 194: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 194/430

193

F L E X I B L E C A B L E S F O

R I N D U S T R I A L

E L E C T R O N I C S

E L K A B E L

L iYY . . . 2x0 .25m m 2 , L iYY . . . 2x0 .75m m 2

L iYY . . . 2x0 .34m m 2 , L iYY . . . 2x1 .00m m 2

L iYY . . . 2x0 .50m m 2 , L iYY . . . 2x1 .50m m 2

according to VDE 0812

Application

These non-screened flexible control and interconnecting cables are used in instrumentation and control engineering

where low current consumptions are required, e.g. in industrial electronics, information and transmission systems,office machines and precision mechanics. These cables are ideal for voice communication in telecommunications sys-tems. These cables are also suitable for flexible and permanent installation for unimpeded movement, without tensileload and without forced movement in dry rooms.

Construction data LiYY...

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Construction data LiYY...

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2õ0,25 mm2

1 3,7 4,8 282 5,4 9,5 363 5,7 14,0 454 6,3 18,8 545 6,9 23,5 16

2x0,34 mm2

1 3,9 2,9 152 5,7 5,6 263 6,1 8,8 324 6,7 11,0 395 7,4 14,0 47

x2õ05 mm2

1 4,7 8,7 252 7,1 17,5 453 7,5 26,2 60

4 9,3 35,0 985 10,2 44,0 116

2x0,75 mm2

1 5,1 14,2 322 7,8 28,4 603 9,3 42,6 1024 10,1 56,9 1275 11,1 71,0 152

x2õ1,0 mm2

1 6,4 19,0 392 9,4 38,0 943 9,9 56,0 1224 10,8 76,0 1525 11,9 95,0 182

2x1,5 mm2

1 6,4 28,0 532 11,0 55,5 1263 11,6 83,3 167

4 12,8 111,1 2105 14,1 139,0 154

PVC insulation pairs stranded in layers sheath of PVC.

Cable construction Technical data

Conductor plain Cu wires, flexibleConstruction 0.25mm2 = 14x0.15mmof conductor 0.34mm2 = 7x0.25mm

0.50mm2 = 16x0.2mm0.75mm2 = 24x0.2mm1.00mm2 = 32x0.2mm1.50mm2 = 30x0.25mm

Insulation PVC insulation type YI2 according to

VDE 0207,part 4Pairs each 2 wires are twisted to a pairCore color coded according to DIN 47 100identificationCable core the pairs are stranded into layer

Wrapping plastic foil overlappingSheath of PVC compound type YM1 accord

ing to VDE 0207 part 5Sheath color gray, RAL 7032

Cross section - mm2 0.250.340.500.751.0 1.5

Cond. resistance at 20∞C -max. Ω/km:Capacitance (core/core)pF/m

78

120

57

120

39

150

25.5

150

19.1

150

13

150

Mutual capacitance at800Hz-max. 150pF/m

Capacitance unbalances at800Hz; K1 max. 300pF/m

Insulation resistance min. 200 ΩM .km

Test voltage 50Hz, 1 min. 2000VOperating voltage peak

value 500V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radius 10 x cable diameter

Page 195: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 195/430

Cable construction Technical data

Color coding

Type codesLi - stranded wire conductor

Y - insulation or sheath of PVCC - screen of copper wire braid

194 E L K A B E L

L iYCY . . . x0 .2 5 mm 2 , L iYCY . . . x0 .7 5 mm 2

L iYCY . . . x0 .3 4 mm 2 , L iYCY . . . x1 .0 mm 2

L iYCY . . . x0 .5 0 mm 2 , L iYCY . . . x1 .5 mm 2

According to VDE 0812

Application

These screened flexible control and interconnecting cables are used in instrumentation and control engineering wherelow current consumptions are required and transmission of the data must be continuous, e.g. in industrial electronics,information and transmission systems, office machines and precision mechanics.These cables are suitable for voice communication in telecommunications systems.The overall braided screen, consisting of tinned copper wires with a visible coverage of approx. 85% provides protec-tion against external pulses.These cables are also suitable for flexible and permanent installation in dry rooms

F L E X I B L E C A B L

E S F O R I N D U S T

R I A L E L E C T R O

N I C S

Conductor ωÂÌ, „˙‚͇‚Construction 0.25mm2 = 14x0.15mm

of conductor 0.34mm2 = 7x0.25mm0.50mm2 = 16x0.2mm0.75mm2 = 24x0.2mm1.00mm2 = 32x0.2mm1.50mm2 = 30x0.25mm

Insulation PVC insulation type YI2 according toVDE 0207, part 4

Core color coded according to DIN 47 100identification Type of lay-up cores laid up in

layers of optimum pitch Wrapping plastic foil overlappingScreen braid of tinned copper

wires, coverage approx. 85%Sheath of PVC compound type YM1 accord

ing to VDE 0207 part 5

Sheath color gray, RAL 7032

Cross section - mm2 0.250.340.500.751.0 1.5

Cond. resistance at 20∞C -

max. Ω/km:Capacitance , pF/m- (core/core)- (core/screen)

78

110220

57

110250

39

120260

25.5

130320

19.1

130350

13

130360

Insulation resistance min. 200 ΩM .km

Test voltage 50Hz, 1 min. 1200V

Operating voltage peak value 500V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radius 15 x cable diameter

Number ofwires

colorNumber of

wirescolor

1 white 6 pink

2 brown 7 blue

3 green 8 red

4 yellow 9 black

5 gray 10 violet

Page 196: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 196/430

195

F L E X I B L E C A B L E S F O

R I N D U S T R I A L

E L E C T R O N I C S

PVC insulation wires stranded in layers with Cu screen sheath of PVC.

Construction data LiYCY...

Number

of wires

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

Construction data LiYCY...

Number

of wires

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

õ0,25 mm2

2 4,1 14 263 4,3 16 324 4,6 20 375 5,0 23 426 5,3 25 497 5,3 29 528 6,0 39 689 6,3 44 7610 6,8 47 78

x0,34 mm2

2 3,9 17 343 4,1 22 434 4,4 25 525 4,8 30 626 5,2 38 737 5,2 42 838 5,7 50 1019 6,0 55 11210 6,6 62 120

õ0,5 mm2

2 5,1 22 383 5,3 26 464 6,0 35 605 6,5 46 756 7,0 52 86

7 7,0 55 908 7,7 65 1109 8,1 72 12510 9,8 77 148

x0,75 mm2

2 5,7 35 553 5,9 42 654 6,4 52 795 7,0 60 926 7,6 75 1127 7,6 80 1178 8,4 89 1429 9,8 97 18010 10,6 108 185

õ1,0 mm2

2 5,4 35 563 5,7 45 704 6,3 53 835 6,9 64 1006 7,5 75 1207 7,5 83 1258 9,4 93 1749 9,8 101 19010 10,6 112 196

x1,5 mm2

2 5,4 35 563 5,7 45 704 6,3 53 835 6,9 64 1006 7,5 75 120

7 7,5 83 1258 9,4 93 1749 9,8 101 19010 10,6 112 196

E L K A B E L

Page 197: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 197/430

Cable construction Technical data

Color coding

196 E L K A B E L

L iYCY . . . x2 x0 .25mm 2 ; L iYCY . . . x2 x1 .00mm 2

L iYCY . . . x2 x0 .50mm 2 ; L iYCY . . . x2 x1 .50mm 2

L iYCY . . . x2 x0 .75mm 2 ;

According to VDE 0812

Application

These cables are ideal for voice communication in telecommunication systems, for pulse, signal and data transmissionapplications.The twisted pairs with optimum pair and layer pitch prevent mutual interaction from neighboring conductor circuits.The overall braided screen, consisting of tinned copper wires with a visible coverage of approx. 85% provides protec-tion against external pulses.These cables are also suitable for flexible and permanent installation in dry and moist rooms.

F L E X I B L E C A B L

E S F O R I N D U S T

R I A L E L E C T R O

N I C S

Conductor plain Cu wires, flexibleConstruction 0.25mm2 = 14x0.15of conductor 0.50mm2 = 16x0.25

0.75mm2 = 24x0.201.00mm2 = 32x0.201.50mm2 = 30x0.25

Insulation PVC insulation type YI2 according toVDE 0207, part 4

Core color coded according to DIN 47 100identificationPairs each 2 wires are twisted to a pairCable core The pairs are stranded info layers

Wrapping plastic foil overlappingScreen braid of tinned copper

wires, coverage approx. 85%Sheath of PVC compound type YM1 accord

ing to VDE 0207 part 5Sheath color gray, RAL 7032

Number ofpairs

a-wire b - wire

1 white brown

2 green yellow

3 gray pink

4 blue red

5 black violet

Cross section in mm2 0.250.340.50 0.751.0 1.5

Cond. resistance at 20∞C -max. Ω/km:

Capacitance , pF/mcore/corecore/screen

78

110220

57

110250

39

120260

25.5

130320

19.1

130350

13

130360

Mutual capacitanceat 800Hz-max. 150pF/m

Insulation resistance min. 200 ΩM .km

Capacitance unbalancesat 800 Hz K1 max 300pF/100m

Test voltage 50Hz, 1 min. 1200V

Operating voltage peak value 500V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radius 15 x cable diameter

Type codesLi - stranded wire conductor

Y - insulation or sheath of PVCC - screen of copper wire braid

Page 198: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 198/430

197

F L E X I B L E C A B L E S F O

R I N D U S T R I A L

E L E C T R O N I C S

PVC insulation pairs stranded in layers with Cu screen sheath of PVC.

Construction data LiYCY...

Number

of pairs

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

2õ0,25 mm2

1 4,1 15 262 6,0 29 493 6,3 38 604 6,9 44 725 7,5 55 85

2x0,5 mm2

1 4,7 20 402 7,1 40 803 7,5 48 1004 9,3 80 133

5 10,2 93 1552õ0,75 mm2

1 5,1 35 552 8,8 62 1153 9,3 75 1384 10,1 95 1655 11,1 115 195

2x1,0 mm2

1 5,4 38 582 9,4 72 1303 9,9 95 1604 10,8 117 1985 11,9 140 230

2õ1,5 mm2

1 6,4 52 79

2 11,0 98 1703 11,6 130 2154 12,8 160 2655 14,1 195 310

E L K A B E L

Page 199: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 199/430

Cable construction Technical data

Color coding

Type codesLi - stranded wire conductor

Y - insulation of PVC Y-fr - sheath of PVC, flame retardant

198 E L K A B E L

L iYY - f r . . . x0 . 25m m2 / 900V , L iYY - f r . . . x0 . 75m m2 / 900V

L iYY - f r . . . x0 . 34m m2 / 900V , L iYY - f r . . . x1 . 00m m2 / 900V

L iYY - f r . . . x0 . 50m m2 / 900V , L iYY - f r . . . x1 . 50m m2 / 900V

According to VDE 0812

Application

These non-screened flexible control and interconnecting cables are used in instrumentation and control engineeringwhere low current consumptions are required, e.g. in industrial electronics, information and transmission systems,office machines and precision mechanics.These cables are ideal for voice communication in telecommunications systems.These cables are also suitable for flexible and permanent installation for unimpeded movement, without tensile loadand without forced movement in dry rooms, when require non-proliferation of flames.

F

L E X I B L E C A B L E

S F O R I N D U S T

R I A L E L E C T R O N I C S ,

F L A M E R E T A R D A N T

Conductor plain Cu wires, flexibleConstruction 0.25mm2 = 14x0.15mmof conductor 0.34mm2 = 7x0.25mm

0.50mm2 = 16x0.2mm0.75mm2 = 24x0.2mm1.00mm2 = 32x0.2mm1.50mm2 = 30x0.25mm

Insulation PVC insulation type YI2 according toVDE 0207,part 4

Core color coded according to DIN 47 100identification Type of lay-up cores laid up in

layers of optimum pitch Wrapping plastic foil overlappingSheath of PVC compound flame retardant and

reduced corrosive gas emmissionSheath color gray, RAL 7032

Number ofwires

colorNumber of

wirescolor

1 white 6 pink

2 brown 7 blue

3 green 8 red

4 yellow 9 black

5 gray 10 violet

Cross section - mm2 0.250.340.500.751.0 1.5

Cond. resistance at 20∞C -max. Ω/km:

Capacitance (core/core)pF/m

78

120

57

120

39

150

25.5

150

19.1

150

13

150

Mutual capacitance at800Hz-max. :

150

Insulation resistance min.MΩ.km

200

Test voltage 50Hz, 1 min. 2500

Operating voltage peak value 900

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Flame retardancy BDS IEC 332-3 ; Category C

Minimum bending radius 10 x cable diameter

Page 200: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 200/430

199

F L E X I B L E C A B L E S F O

R I N D U S T R I A L

E L E C T R O N I C S

,

F L A M

E R E T A R D A N T

PVC insulation wires stranded in layers sheath of PVC.

Construction data LiYY-fr...

Number

of wires

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

Construction data LiYY-fr...

Number

of wires

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

x0,25 mm2/ 900V2 3,7 4,6 16,03 3,9 7,0 20,04 4,2 9,3 25,05 4,6 11,8 30,06 4,9 14,0 35,07 4,9 16,5 39,08 5,4 19,0 45,09 5,7 21,0 48,010 6,2 23,5 53,0

x0,34 mm2/ 900V

2 3,9 6,5 19,03 4,1 9,8 25,04 4,4 13,1 30,05 4,8 16,3 35,06 5,2 20,0 42,07 5,2 23,0 47,08 5,7 26,1 53,09 6,0 30,0 57,010 6,6 32,6 65,0

x0,50 mm2/ 900V2 4,7 8,8 26,03 4,9 13,2 35,04 5,4 18,0 42,05 5,9 22,0 50,06 6,4 26,0 58,0

7 6,4 32,0 65,08 7,1 36,0 75,09 7,5 40,0 82,010 8,2 45,0 90,0

x0,75 mm2/ 900V2 5,1 14,3 323 5,3 22,0 434 5,8 28,5 545 6,4 35,5 666 7,0 42,5 777 7,0 50,0 888 7,8 57,0 999 8,2 64,0 11010 10,0 71,0 135

x1,0 mm2/ 900V

2 5,4 19,0 393 5,7 28,5 524 6,3 38,0 665 6,9 47,5 806 7,5 56,0 957 7,5 66,0 1078 8,4 75,8 1229 9,8 85,0 15810 10,6 95,0 175

x1,5 mm2/ 900V2 6,4 28,0 533 6,7 42,0 734 7,4 55,0 935 8,2 69,1 1146 10,0 83,0 158

7 10,0 97,0 1768 11,0 111,0 2009 11,5 125,0 22110 12,6 139,0 245

E L K A B E L

Page 201: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 201/430

Cable construction Technical data

Color coding

Type codesLi - stranded wire conductor

Y - insulation of PVC Y-fr - sheath of PVC, flame retardant

200 E L K A B E L

L iYY - f r . . . x0 .50mm 2 / 1500V ,

L iYY - f r . . . x0 .75mm 2 / 1500V

according to VDE 0812

Application

These non-screened flexible control and interconnecting cables are used in instrumentation and control engineeringwhere low current consumptions are required, e.g. in industrial electronics, information and transmission systems,office machines and precision mechanics.These cables are ideal for voice communication in telecommunications systems.These cables are also suitable for flexible and permanent installation for unimpeded movement, without tensile loadand without forced movement in dry rooms, when require non-proliferation of flames.

F L E X I B L E C A B L

E S F O R I N D U S T

R I A L E L E C T R O

N I C S

F L A M E R E T A R D A N T

Conductor plain Cu wires, flexibleConstruction 0.50mm2 = 16x0.2of conductor 0.75mm2 = 24x0.2

Insulation PVC insulation type YI2 according toVDE 0207, part 4

Core color coded according to DIN 47 100identification Type of lay-up: cores laid up in

layers of optimum pitch Wrapping plastic foil overlappingSheath of PVC compound flame retardant and

reduced corrosive gas emmissionSheath color gray, RAL 7032

Cross section - mm2 0.50 0.75

Cond. resistance at 20∞C -max. Ω/km:

Capacitance, pF/mcore/core:

39.0

120

25.5

120

Mutual capacitance at800Hz-max. 150pF/m

Insulation resistance min. 200 ΩM .km

Test voltage 50Hz, 1 min. 3000V

Operating voltage peak value 1500V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Flame retardancy BDS IEC 332-3 Category C

Minimum bending radius 10 x cable diameter

Number ofwires

colorNumber of

wirescolor

1 white 6 pink

2 brown 7 blue

3 green 8 red

4 yellow 9 black

5 gray 10 violet

Page 202: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 202/430

201

F L E X I B L E C A B L E S F O

R I N D U S T R I A L

E L E C T R O N I C S

F L A M

E R E T A R D A N T

PVC insulation wires stranded in layers sheath of PVC.

Construction data LiYY-fr...

Number

of wires

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

x0,50 mm2/1500 VZZ2 5,5 8,8 313 5,8 13,0 404 6,3 17,4 505 7,0 22,0 606 7,6 26,0 707 7,6 30,5 798 8,5 35,0 909 9,9 39,0 123

10 10,8 43,4 136

x0,75 mm2/1500 V2 6,3 14,2 42

3 6,6 21,2 564 7,3 28,3 705 8,0 35,3 856 9,8 42,4 1237 9,8 50,0 1368 10,8 56,0 1549 11,3 64,0 170

10 12,4 71,0 188

E L K A B E L

Page 203: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 203/430

Cable construction

Color coding

202 E L K A B E L

L iYY - f r . . . 2x0 .25mm 2 ; L iYY - f r . . . 2x0 .75mm 2

L iYY - f r . . . 2x0 .34mm 2 ; L iYY - f r . . . 2x1 .00mm 2

L iYY - f r . . . 2x0 .50mm 2 ; L iYY - f r . . . 2x1 .50mm 2

according to VDE 0812

Technical data

Application

These non-screened flexible control and interconnecting cables are used in instrumentation and control engineeringwhere low current consumptions are required, e.g. in industrial electronics, information and transmission systems,office machines and precision mechanics.These cables are ideal for voice communication in telecommunications systems.These cables are also suitable for flexible and permanent installation for unimpeded movement, without tensile loadand without forced movement in dry rooms, when require non-proliferation of flames.

F L E X I B L E C A B L

E S F O R I N D U S T

R I A L E L E C T R O

N I C S

F L A M E R E T A R D A N T

Type codesLi - stranded wire conductor

Y - insulation of PVC Y-fr - sheath of PVC, flame retardant

Conductor plain Cu wires, flexibleConstruction 0.25mm2 = 14x0.15mmof conductor 0.34mm2 = 7x0.25mm

0.50mm2 = 16x0.2mm0.75mm2 = 24x0.2mm1.00mm2 = 32x0.2mm1.50mm2 = 30x0.25mm

Insulation PVC insulation type YI2 according toVDE 0207,part 4

Pairs each 2 wires are twisted to a pairCore color coded according to DIN 47 100identificationCable core the pairs are stranded into layer

Wrapping plastic foil overlappingSheath of PVC compound flame retardant and

reduced corrosive gas emmissionSheath color gray, RAL 7032

Cross section - mm2 0.250.340.50 0.751.0 1.5

Cond. resistance at 20∞C -max. Ω/km:Capacitance (core/core)pF/m

78

120

57

120

39

150

25.5

150

19.1

150

13

150

Mutual capacitance at800Hz-max.

150

Capacitance unbalances at800Hz ; K1 max

300

Insulation resistance min.MΩ.km

200

Test voltage 50Hz, 1 min. 2000V

Operating voltage peak value 500V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Flame retardancy BDS IEC 332-3 ; Category C

Minimum bending radius 10 x cable diameter

Number ofpairs

a-wire b - wire

1 white brown

2 green yellow

3 gray pink

4 blue red

5 black violet

Page 204: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 204/430

203

F L E X I B L E C A B L E S F O

R I N D U S T R I A L

E L E C T R O N I C S

F L A M

E R E T A R D A N T

PVC insulation pairs stranded in layers sheath of PVC

Construction data LiYY-fr...

Number

of pairs

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

Construction data LiYY-fr...

Number

of pairs

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

x2õ0,25 mm2

1 3,7 4,8 282 5,4 9,5 363 5,7 14,0 454 6,3 18,8 545 6,9 23,5 16

2x0,34 mm2

1 3,9 2,9 152 5,7 5,6 263 6,1 8,8 324 6,7 11,0 39

5 7,4 14,0 47x2õ0,5 mm2

1 4,7 8,7 252 7,1 17,5 453 7,5 26,2 604 9,3 35,0 985 10,2 44,0 116

2x0,75 mm2

1 5,1 14,2 322 7,8 28,4 603 9,3 42,6 1024 10,1 56,9 1275 11,1 71,0 152

x2õ1,0 mm2

1 6,4 19,0 392 9,4 38,0 943 9,9 56,0 1224 10,8 76,0 152

5 11,9 95,0 1822x1,5 mm2

1 6,4 28,0 532 11,0 55,5 1263 11,6 83,3 1674 12,8 111,1 2105 14,1 139,0 154

E L K A B E L

Page 205: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 205/430

Technical data

Type codesLi - stranded wire conductor

Y - insulation of PVCC - screen of copper wire braid

Y-fr - sheath of PVC, flame retardant

204 E L K A B E L

L iYCY- f r . . . x0 .25mm 2 ; L iYCY- f r . . . x0 .75mm 2

L iYCY- f r . . . x0 .34mm 2 L iYCY- f r . . . x1 .0mm 2

L iYCY- f r . . . x0 .50mm 2 ; L iYCY- f r . . . x1 .5mm 2

According to VDE 0812

Cable construction

Color coding

Application

These screened flexible control and interconnecting cables are used in instrumentation and control engineering wherelow current consumptions are required and transmission of the data must be continuous, e.g. in industrial electronics,information and transmission systems, office machines and precision mechanics. These cables are suitable for voicecommunication in telecommunications systems. The overall braided screen, consisting of tinned copper wires with avisible coverage of approx. 85% provides protection against external pulses. These cables are also suitable for flexibleand permanent installation in dry rooms, when require non-proliferation of flames.

F

L E X I B L E C A B L E

S F O R I N D U S T

R I A L E L E C T R O N I C S ,

F L A M E R E T A R D A N T

Conductor plain Cu wires, flexibleConstruction 0.25mm2 = 14x0.15mmof conductor 0.34mm2 = 7x0.25mm

0.50mm2 = 16x0.2mm0.75mm2 = 24x0.2mm1.00mm2 = 32x0.2mm1.50mm2 = 30x0.25mm

Insulation PVC insulation type YI2 according toVDE 0207, part 4

Core color coded according to DIN 47 100identificationType of lay-up cores laid up in layers of optimum

pitch Wrapping plastic foil overlappingScreen braid of tinned copper

wires, coverage approx. 85%Sheath of PVC compound fire retardant and

reduced corrosive gas emmissionSheath color gray, RAL 7032

Cross section - mm2 0.250.340.50 0.751.0 1.5

Cond. resistance at 20∞C -

max. Ω/km:Capacitance , pF/m- (core/core)- (core/screen)

78

110220

57

110250

39

120260

25.5

130320

19.1

130350

13

130360

Insulation resistance min. 200 ΩM .km

Test voltage 50Hz, 1 min. 1200V

Operating voltage peak value

500V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Flame retardancy ¡ƒ— IEC 332-3 ; ͇Ú„ÓË "—"

Minimum bending radius 15 x ‰Ë‡ÏÂÚ˙‡ ̇ ͇·Â·

Number ofwires

colorNumber of

wirescolor

1 white 6 pink

2 brown 7 blue

3 green 8 red

4 yellow 9 black

5 gray 10 violet

Page 206: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 206/430

205

F L E X I B L E C A B L E S F O

R I N D U S T R I A L

E L E C T R O N I C S

,

F L A M

E R E T A R D A N T

PVC insulation wires stranded in layers with Cu screen

sheath of PVC.

Construction data LiYCY-fr...

Number

of wires

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

Construction data LiYCY-fr...

Number

of wires

External

diameterapprox.

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

õ0,25 mm2

2 4,1 14 263 4,3 16 324 4,6 20 375 5,0 23 426 5,3 25 497 5,3 29 528 6,0 39 689 6,3 44 7610 6,8 47 78

x0,34 mm2

2 3,9 17 343 4,1 22 434 4,4 25 525 4,8 30 626 5,2 38 737 5,2 42 838 5,7 50 1019 6,0 55 11210 6,6 62 120

õ0,5 mm2

2 5,1 22 383 5,3 26 464 6,0 35 605 6,5 46 756 7,0 52 86

7 7,0 55 908 7,7 65 1109 8,1 72 12510 9,8 77 148

x0,75 mm2

2 5,7 35 553 5,9 42 654 6,4 52 795 7,0 60 926 7,6 75 1127 7,6 80 1178 8,4 89 1429 9,8 97 18010 10,6 108 185

õ1,0 mm2

2 5,4 35 563 5,7 45 704 6,3 53 835 6,9 64 1006 7,5 75 1207 7,5 83 1258 9,4 93 1749 9,8 101 19010 10,6 112 196

x1,5 mm2

2 5,4 35 563 5,7 45 704 6,3 53 835 6,9 64 1006 7,5 75 120

7 7,5 83 1258 9,4 93 1749 9,8 101 19010 10,6 112 196

E L K A B E L

Page 207: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 207/430

Technical data

Colour coding

206 E L K A B E L

L iYCY- f r . . . x2 x0 .25mm 2 ; L iYCY- f r . . . x2 x1 .00mm 2

L iYCY- f r . . . x2 x0 .50mm 2 ; L iYCY- f r . . . x2 x1 .50mm 2

L iYCY- f r . . . x2 x0 .75mm 2

According to VDE 0812

Application

These cables are ideal for voice communication in telecommunication systems, for pulse, signal and data transmissionapplications.The twisted pairs with optimum pair and layer pitch prevent mutual interaction from neighboring conductor circuits.The overall braided screen, consisting of tinned copper wires with a visible coverage of approx. 85% provides protec-tion against external pulses.These cables are also suitable for flexible and permanent installation in dry and moist rooms , when require non-prolif-eration of flames.

F

L E X I B L E C A B L E

S F O R I N D U S T

R I A L E L E C T R O N I C S ,

F L A M E R E T A R D A N T

Type codesLi - stranded wire conductor Y - insulation of PVCC - screen of copper wire braid Y-fr - sheath of PVC, flame retardant

Conductor plain Cu wires, flexibleConstruction 0.25mm2 = 14x0.15of conductor 0.50mm2 = 16x0.25

0.75mm2 = 24x0.201.00mm2 = 32x0.201.50mm2 = 30x0.25

Insulation PVC insulation type YI2 according toVDE 0207, part 4

Core color coded according to DIN 47 100identificationPairs each 2 wires are twisted to a pairCable core The pairs are stranded info layers

Wrapping plastic foil overlappingScreen braid of tinned copper

wires, coverage approx. 85%Sheath of PVC compound fire retardant and

reduced corrosive gas emmissionSheath color gray, RAL 7032

Cross section in mm2 0.25 0.50 0.75 1.0 1.50Cond. resistance at 20∞C -max. Ω/km:

Capacitance , pF/mcore/corecore/screen

80

130220

39

150260

26

150300

19.5

150300

13.3

150300

Mutual capacitanceat 800Hz-max. 150pF/m

Insulation resistance min. 200 ΩM .km

Capacitance unbalancesat 800 Hz K1 max 300pF/100m

Test voltage 50Hz, 1 min. 1200V

Operating voltage peak value 500V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Flame retardancy BDS IEC 332-3 ; CategoryC

Minimum bending radius 15 x cable diameter

Cable construction

Number ofpairs

a-wire b - wire

1 white brown

2 green yellow

3 gray pink

4 blue red

5 black violet

Page 208: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 208/430

207

F L E X I B L E C A B L E S F O

R I N D U S T R I A L

E L E C T R O N I C S

,

F L A M

E R E T A R D A N T

PVC insulation pairs stranded in layers with Cu screen

sheath of PVC.

Construction data LiYCY-fr...

Number

of pairs

External

diameterapprox

Copper

weight

Cable

weightapprox.

mm kg/km kg/km

2õ0,25 mm2

1 4,1 15 262 6,0 29 493 6,3 38 604 6,9 44 725 7,5 55 85

2x0,5 mm2

1 4,7 20 402 7,1 40 803 7,5 48 1004 9,3 80 133

5 10,2 93 1552õ0,75 mm2

1 5,1 35 552 8,8 62 1153 9,3 75 1384 10,1 95 1655 11,1 115 195

2x1,0 mm2

1 5,4 38 582 9,4 72 1303 9,9 95 1604 10,8 117 1985 11,9 140 230

2õ1,5 mm2

1 6,4 52 79

2 11,0 98 1703 11,6 130 2154 12,8 160 2655 14,1 195 310

E L K A B E L

Page 209: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 209/430

Cable construction Technical data

Type codesRE control cable2Y PE insulation(St) static screen

Y PVC sheathLg laid up in layers

Conductor bare copper conductoraccording to BS 6746,nominal area:

0.5mm2- class 1 - 1/0.8mm1.0mm2- class 1 - 1/1.13mm0.5mm2- class 5 - 16/0.2mm1.5mm2- class 2 - 7/0.53

Insulation PE insulation type 03according to BS 6234

Pairs each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping several layers of plastic tapesScreen of aluminum tape one side

coated with polyester and 1tinned copper wire 0.5mm2

Sheath of PVC compound type TM1according to BS 6746, colored black

208 E L K A B E L

RE-2Y(St )Y . . . x2x0 .5 mm 2 /1 c lass Lg

RE-2Y(St )Y . . . x2x1 .0 mm 2 /1 c lass Lg

RE-2Y(St )Y . . . x2x0 .5 mm 2 /5 c lass Lg

RE-2Y(St )Y . . . x2x1 .5 mm 2 /2 c lass Lg

according to BS 5308 part 1

Application

These cables are used for computers and process control in industrial plant.The screen of metal foil protects the circuits from external interfering signals. The low operating capacity makes possi-ble data transfer to long distances.The cables are suitable for fixed installation in dry and wet premises as well as for outdoor installation on the walls ofbuildings.The use of these cables for power installations and underground installation is not permitted.

I N S T R U M

E N T A T I O N A N D

C O N T R O L C A

B L E S

Cross section in mm2/class 0.5/1 1.0/1 0.5/5 1.5/2

Cond. resistance -maxΩ/km 36.8 18.4 39.7 12.3

Mutual capacitance at800Hz- max. nF/km

75 75 75 85

Insulation resistance min. 5 GΩ.km

Capacitance unbalances at800Hz K1- max.

250pF/250m

Test voltage 50Hz, 1 min.wire - wire

wire - screen1000V1000V

Operating voltage peak value 300V

Temperature rangemobile

fixed

0∞C ‰Ó +50∞C

-40∞C ‰Ó +65∞CMinimum bending radiusapprox. 7.5 x cable diameter

Cable core construction

Numberof pairs

Number of pairs in centre and successive layersFirst layer Second layer Third layer Fourth layer

1 1

2 2(quad)5 510 2 8

15 5 1020 1 6 13

30 4 10 1650 4 10 15 21

Page 210: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 210/430

209L K A B E L

I N S T R

U ME N T A T I O N A N D C O N T R O L

C A B L E S

PE insulation pairs stranded in layers static screen sheathof PVC.

Color coding

Pair no. a - wire b - wire Pair no. a - wire b - wire

Construction data RE - 2Y(St)Y...

Numberof pairs

External

diameterapprox.

Copper weight

Cable

weightapprox.

mm kg/km kg/km

Construction data RE - 2Y(St)Y...

Numberof pairs

External

diameterapprox.

Copper weight

Cable

weightapprox.

mm kg/km kg/km

x2x0,5 mm2

/1class Lg1 5,4 14 362 6,2 23 525 10,7 52 12110 13,9 99 21115 16,2 147 28720 18,5 194 37330 22,1 289 52650 28,1 478 847

x2x1,0 mm2

/1class Lg1 6,5 23 512 7,5 42 805 13,4 99 19710 17,6 193 34415 20,5 280 49120 23,6 381 65030 28,1 570 92850 36,4 947 1547

x2x0,5 ìì2

/5class Lg1 6,1 13 402 7,0 22 575 12,3 49 13510 16,3 94 23615 19,0 139 32720 21,4 184 41430 26,0 274 60550 33,0 454 965

x2x1,5 ìì2

/2class Lg1 7,4 34 672 8,8 64 1125 15,5 152 26910 20,7 300 49015 24,3 448 71420 27,6 597 92130 33,4 893 135450 42,7 1485 2211

1 white blue 11 black blue2 white orange 12 black orange3 white green 13 black green4 white brown 14 black brown5 white gray 15 black gray6 red blue 16 yellow blue7 red orange 17 yellow orange8 red green 18 yellow green9 red brown 19 yellow brown

10 red gray 20 yellow gray

Page 211: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 211/430

Cable construction Technical data

Cable core construction

Numberof pairs

Number of pairs in centre and successive layers

First layer Second layer Third layer Fourth layer

1 1

2 2(quad)

5 5

10 2 8

15 5 10

20 1 6 13

Type codesRD - control cable

Y insulation or sheath of PVC(St) static screenLg laid up in layers

Conductor bare copper conductoraccording to BS 6746,nominal area:0.5ÏÏ2- class 5 - 6/0.2ÏÏ0.75ÏÏ2- class 5 - 24/0.2ÏÏ 1.5ÏÏ2-class 2 - 7/0.53ÏÏ

Insulation PVC insulation type TI1according to BS 6746

Pairs ach 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping several layers of plastic tapesScreen of aluminum tape one side

coated with polyester and 1tinned copper wire 0.5mm2

Sheath of PVC compound type TM1according to BS 6746, colored black

210 E L K A B E L

RD- Y (S t )Y - x2x0 .5 m m 2 / 5 c lass Lg

RD- Y (S t )Y - x2x0 .75 m m 2 / 5 c lass Lg

RD- Y (S t )Y - x2x1 .5 m m 2 / 2 c lass Lg

according to BS 5308 part 2

Application

These cables are used for data transfer in measuring and control appliancesThe screen of metal foil protects the circuits from external interfering signals.The cables are suitable for fixed installation in dry and wet premises as well as for outdoor installation on the walls ofbuildings.The use of these cables for power installations and underground installation is not permitted.

I N S T R U M

E N T A T I O N A N D

C O N T R O L C A

B L E S

Cross section in mm2/class 0.5/5 0.75/5 1.5/2

Cond. resistance - max.Ω/km 39.7 26.5 12.3

Mutual capacitance at800Hz-max.

250nF/m

Insulation resistance min. 100 ΩM .km

Capacitance unbalances at800Hz K1- max.

250pF/250m

Test voltage 50Hz, 1 min.wire - wire

wire - screen1000V1000V

Operating voltage peak value 300V

Temperature rangemobile

fixed

-5∞C ‰Ó +50∞C

-40∞C ‰Ó +65∞CMinimum bending radiusapprox. 7.5 x cable diameter

Page 212: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 212/430

211

I N S T R

U ME N T A T I O N

A N D C O N T R O L

C A B L E S

PVC insulation pairs stranded in layers static screen sheath of PVC.

Color coding

Pair no a - wire b - wire Pair no a - wire b - wire

Construction data

Numberof pairs

External

diameterapprox.

Copper weight

Cable

weightapprox.

mm kg/km kg/km

x2x0,5ìì2

/5class Lg1 6,1 13 422 7,0 22 635 12,3 49 148

10 16,3 94 26215 19,0 139 36620 21,4 184 465

x2x0,75ìì2

/5class Lg

1 6,5 19 502 7,5 34 725 13,2 78 171

10 17,6 151 30615 20,5 224 43020 23,3 298 550

x2x1,5ìì2

/5class Lg1 7,4 34 712 8,8 64 1125 15,5 152 269

10 20,7 300 49115 24,3 448 714

20 27,6 597 920

1 white blue 11 black blue2 white orange 12 black orange3 white green 13 black green4 white brown 14 black brown5 white gray 15 black gray6 red blue 16 yellow blue7 red orange 17 yellow orange8 red green 18 yellow green9 red brown 19 yellow brown

10 red gray 20 yellow gray

E L K A B E L

Page 213: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 213/430

Cable construction Technical data

Cable core construction

Numberof pairs

Number of pairs in centre and successive layersFirst layer Second layer Third layer Fourth layer

1 12 24 48 1 712 3 916 5 1120 1 6 13

24 2 8 14

Type codesRE - cable for control2Y insulation of PE(St) static screen

Y-fl sheath of PVC compound flame retardant

Conductor bare copper conductornominal area:0.50mm2 - class 2 or 50.75mm2 - class 2 or 5

Insulation PE insulationPairs each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping of polyester tapesScreen of aluminium tape one side

coated with polyester and 1tinned copper wire 0.5mm2

Outer of PVC compound flamesheath retardantColor black

212 E L K A B E L

RE-2Y(S t )Y - f l Standard:EN 50288-7

Application

These cables are used for data transfer in measuring and control appliancesThe screen of metal foil protects the circuits from external interfering signals.The cables are suitable for fixed installation in dry and wet premises as well as for outdoor installation on the walls ofbuildings, when require non-proliferation of flames.

I N S T R U M

E N T A T I O N A N D

C O N T R O L C A

B L E S

Cross section in mm2/class2 0.5mm2 0.75mm2

Cond. resistance - max. Ω/km 36.8 25.0

Cross section in mm2/class5 0.5mm2 0.75mm2

Cond. resistance - max. 38.2 25.5

Mutual capacitance at800Hz-max.

100nF/km

Insulation resistance min. 5GΩ .km

Capacitance unbalances at800Hz K1- max. 250pF/250m

Test voltage 50Hz, 1 min.wire - wire

wire - screen1000V1500V

L/R ratio - max. H/ 25

Temperature rangemobilefixed

-5∞C to +50∞C-30∞C to +65∞C

Minimum bending radiusapprox. 10 x cable diameter

Flame retardance test according to IEC 60332-3 class C

Page 214: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 214/430

213

I N S T

R U ME N T A T I O N

A N D C O N T R O L

C A B L E S

PE insulation pairs, stranded in layers static screen sheath of PVC flame retardant

Colour coding

Pair no. a - wire b - wire

Construction data RE - 2Y(St)Y-fl...

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Construction data RE - 2Y(St)Y-fl...

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Nx2x0.5mm2

/ class 2, Lg1 6.3 14 432 6.4 23 684 9.2 42 998 11.6 79 165

12 13.9 117 23216 15.6 156 29220 17.3 194 35924 18.6 232 416

Nx2x0.5mm2

/ class 5, Lg1 6.3 13 382 6.4 22 584 9.2 40 978 11.6 75 161

12 13.9 111 22616 15.6 147 28320 17.3 184 34924 18.6 220 404

1 black with sequential numbering imprint white with sequential numbering imprint2 black with sequential numbering imprint white with sequential numbering imprint

E L K A B E L

Page 215: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 215/430

Cable construction Technical data

Type codesRE - instrumental cable2Y insulation of PE(St) static screen

Y-fl sheath of PVC compound fire retardantPiMF screened pairs

Conductor bare copper conductornominal area:0.50mm2 - class 2 or 50.75mm2 - class 2 or 5

Insulation PE insulationPairs each 2 wires are twisted to a pair

PiMF wrapping of plastic foil,construction: drain wire 0.6 mm, tinned Cu, Al-PET foil,

metal side on the inside, foil wrappingCable core the PiMFpairs are stranded

into layers Wrapping of polyester tapesScreen of aluminium tape one side

coated with polyester and 1tinned copper wire 0.5mm2

Inner of PVC compoundsheath

Armour galvanized steel wireOuter sheath of PVC compound fire retardantSheath color black or other colour

214 E L K A B E L

R E-2 Y(S t)Y - f l P iM F Standard: EN 50288-7

Application

These cables are used for data transfer in measuring and control appliancesThe screen of metal foil protects the circuits from external interfering signals.The cables are suitable for fixed installation in dry and wet premises as well as for outdoor installation on the walls ofbuildings, when require non-proliferation of flames.

I N S T R U M

E N T A T I O N A N D

C O N T R O L C A

B L E S

Cross section in mm2/class2 0.5mm2 0.75mm2

Cond. resistance - max. Ω/km 36.8 25.0

Cross section in mm2/class5 0.5mm2 0.75mm2

Cond. resistance - max. 38.2 25.5

Mutual capacitance at800Hz-max. 120nF/km

Insulation resistance min. 5GΩ .km

Capacitance unbalances at800Hz K1- max.

250pF/250m

Test voltage 50Hz, 1 min.wire - wire

wire - screen1000V1500V

L/R ratio - max. H/Ω 25

Temperature rangemobilefixed

-5∞C to +50∞C-30∞C to +65∞C

Minimum bending radiusapprox. 10 x cable diameter

Flame retardance test according to IEC 60332-3 class C

Cable core construction

Numberof pairs

Number of pairs in centre and successive layersFirst layer Second layer Third layer Fourth layer

1 1

2 24 48 1 7

12 3 916 5 1120 1 6 13

24 2 8 14

Page 216: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 216/430

215

I N S

T R U ME N T A T I O N A N D C O N T R O

L C A B L E S

PE insulation pairs, stranded in layers static screen sheath of PVC

Colour coding

Pair no. a - wire b - wire

Construction data RE - 2Y(St)Y-fl...

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Construction data RE - 2Y(St)Y-fl...

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Nx2x0.5mm2

/PiMF class 2, Lg2 9.4 28 884 10.8 51 1308 14.7 98 23312 17.3 144 31916 19.9 191 42120 22.1 238 51524 23.8 284 597

Nx2x0.5mm2

/PiMF class 5, Lg2 9.4 27 874 10.8 49 1288 14.7 94 22912 17.3 139 31316 19.9 183 41320 22.1 228 50524 23.8 273 585

Nx2x0.75mm2

/PiMF class 2, Lg2 10.3 40 1074 12.2 73 1678 16.6 139 29812 19.6 205 41716 21.9 272 53320 24.6 338 65524 27.4 404 780

Nx2x0.75mm2

/PiMF class 5, Lg2 10.3 38 1054 12.2 67 1638 16.6 128 29112 19.6 189 40716 21.9 250 52020 24.4 311 62624 27.4 372 760

1 black with sequential numbering imprint white with sequential numbering imprint2 black with sequential numbering imprint white with sequential numbering imprint

E L K A B E L

Page 217: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 217/430

Cable construction Technical data

Cable core construction

Type codesRE - instrumental cable2Y insulation of PE(St) static screen

Y-fl sheath of PVC compound fire retardantSWA galvanized steel wire

Conductor bare copper conductornominal area:0.50mm2 - class 2 or 50.75mm2 - class 2 or 5

Insulation PE insulationPairs each 2 wires are twisted to a pair

Cable core the pairs are stranded into layers Wrapping of polyester tapesScreen of aluminium tape one side

coated with polyester and 1tinned copper wire 0.5mm2

Inner of PVC compoundsheath

Armour galvanized steel wireOuter sheath of PVC compound fire retardantSheath color black

216 E L K A B E L

R E -2Y ( S t ) YS WA Y- f l Standard: EN 50288-7

Application

These cables are used for data transfer in measuring and control appliancesThe screen of metal foil protects the circuits from external interfering signals.The cables are suitable for fixed installation in dry and wet premises as well as for outdoor installation on the walls ofbuildings, when require non-proliferation of flames.

I N S T R U M

E N T A T I O N A N D

C O N T R O L C A

B L E S

Cross section in mm2/class2 0.5mm2 0.75mm2

Cond. resistance - max. Ω/km 36.8 25.0

Cross section in mm2/class5 0.5mm2 0.75mm2

Cond. resistance - max. 38.2 25.5

Mutual capacitance at800Hz-max. 100nF/km

Insulation resistance min. 5GΩ .km

Capacitance unbalances at800Hz K1- max. 250pF/250m

Test voltage 50Hz, 1 min.wire - wire

wire - screen1000V1500V

L/R ratio - max. H/ Ω 25

Temperature rangemobilefixed

-5∞C to +50∞C-30∞C to +65∞C

Minimum bending radiusapprox. 10 x cable diameter

Flame retardancetest according to IEC 60332-3 class C

Numberof pairs

Number of pairs in centre and successive layersFirst layer Second layer Third layer Fourth layer

1 12 24 48 1 712 3 916 5 11

20 1 6 1324 2 8 14

Page 218: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 218/430

217

I N S T

R U ME N T A T I O N

A N D C O N T R O L C A B L E S

PE insulation pairs, stranded in layers static screen beddingof PVC armoured sheat of PVC

Construction data R≈-2Y(St)YSWAY-fl...

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Construction data R≈-2Y(St)YSWAY-fl...

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Nx2x0.5mm2

/ class 2

1 10.3 23 2362 12.6 23 3074 13.8 42 3678 16.4 80 502

12 18.7 117 62816 21.3 155 86720 23.2 192 100124 24.5 230 1101

Nx2x0.5mm2

/ class 51 10.3 22 2352 12.6 22 3064 13.8 40 3668 16.4 76 498

12 18.7 111 62316 21.3 147 85920 23.2 182 99224 24.5 218 1090

Nx2x0.75mm2

/ class 2

1 10.2 18 2242 13.1 32 3314 14.5 60 4098 17.4 115 573

12 20.0 171 73116 22.7 227 100520 24.8 285 116624 26.4 341 1304

Nx2x0.75mm2

/ class 51 10.2 17 2232 13.1 30 3294 14.5 56 4068 17.4 109 566

12 20.0 161 72116 22.7 213 99220 24.8 268 114924 26.4 321 1284

Colour coding

Pair no. a - wire b - wire

1 black with sequential numbering imprint white with sequential numbering imprint2 black with sequential numbering imprint white with sequential numbering imprint

E L K A B E L

Page 219: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 219/430

Cable construction

Cable core construction

Conductor bare copper conductornominal area:0.50mm2 - class 2 or 50.75mm2 - class 2 or 5

Insulation PE insulationPairs each 2 wires are twisted to a pair

PiMF wrapping of plastic foil,construction: drain wire 0.6 mm, tinned Cu, Al-PETfoil, metal side on the inside, foilwrapping

Cable core the PiMF pairs are strandedinto layers

Wrapping of polyester tapesScreen of aluminium tape one side

coated with polyester and 1tinned copper wire 0.5mm2

Inner of PVC compoundsheath

Armour galvanized steel wireOuter sheath of PVC compound flame

retardant

Sheath color black or other colour

218 E L K A B E L

RE -2Y(S t )YSWAY- f l - P iMF Standard: EN 50288-7

Application

These cables are used for data transfer in measuring and control appliancesThe screen of metal foil protects the circuits from external interfering signals.The cables are suitable for fixed installation in dry and wet premises as well as for outdoor installation on the walls ofbuildings , when require non-proliferation of flames.

I N S T R U M

E N T A T I O N A N D

C O N T R O L C A

B L E S

Technical data

Type codesRE - data cable2Y insulation of PE(St) static screen

Y-fl sheath of PVC compound fire retardantPiMF screened pairsSWA galvanized steel wire , armour

Cross section in mm2/class2 0.5mm2 0.75mm2

Cond. resistance - max. Ω/km 36.8 25.0

Cross section in mm2/class5 0.5mm2 0.75mm2

Cond. resistance - max. 38.2 25.5

Mutual capacitance at

800Hz-max. 100nF/kmInsulation resistancemin. 5GΩ .km

Capacitance unbalances at800Hz K1- max.

250pF/250m

Test voltage 50Hz, 1 min.wire - wire

wire - screen1000V1500V

L/R ratio - max. H/Ω 25

Operating voltage peak value 300V

Temperature rangemobilefixed

-5∞C to +50∞C-30∞C to +65∞C

Minimum bending radius

approx.10 x cable diameter

Flame retardance test accordingto IEC 60 332-3 class C

Numberof pairs

Number of pairs in centre and successive layersFirst layer Second layer Third layer Fourth layer

1 12 24 48 1 712 3 916 5 11

20 1 6 1324 2 8 14

Page 220: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 220/430

219

I N S T

R U ME N T A T I O N

A N D C O N T R O L C A B L E S

PE insulation pairs, stranded in layers static screen bedding ofPVC Armoured Sheath of PVC

Construction data RE - 2Y(St)YSWAY-fl

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Construction data RE - 2Y(St)YSWAY-fl

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Nx2x0.5mm2

/ PiMF class 22 14.0 28 2684 15.6 52 3348 19.7 100 505

12 23.4 148 78016 25.8 196 93120 28.2 243 107824 29.9 291 1200

Nx2x0.5mm2

/ PiMF class 52 14.0 27 2674 15.6 50 3328 19.7 96 501

12 23.4 142 77416 25.8 188 92320 28.2 234 106824 29.9 279 1189

Nx2x0.75mm2

/ PiMF class 22 14.9 40 3024 17 73 3958 22.3 138 729

12 25.4 204 89916 27.8 270 107620 30.9 336 127824 34.6 402 1674

Nx2x0.75mm2

/ PiMF class 52 14.9 38 3004 17 69 3918 22.3 131 722

12 25.4 194 88916 28 256 107820 30.7 319 124424 34.6 381 1654

Colour coding

Pair no. a - wire b - wire

1 black with sequential numbering imprint white with sequential numbering imprint2 black with sequential numbering imprint white with sequential numbering imprint

E L K A B E L

Page 221: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 221/430

Cable construction Technical data

Type codesRE - control cable2X XLPE insulation(St) static screen

Y-fr sheath of special PVC, flame-retardant

Conductor bare copper conductoraccording to IEC 60228, nominalarea: 0.5mm2 = 7x 0.3 mm

1.0mm2 = 7x0.43mm, class 21.3mm2 = 7x0.49mm, class 2

Insulation XLPE according to IEC 60502-1Core Black/white with imprinted numbersidentification 1/1, 2/2 etc.Pairs each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping several layers of plastic tapesScreen of aluminium tape one side

coated with polyester and 1tinned copper wire 0.5mm2

Sheath of PVC compound , flame-retardantcoloured black

220 E L K A B E L

RE-2X (S t )Y - f r Similar to EN 50288

Application

These cables are used for data transfer in measuring and control appliancesThe screen of metal foil protects the circuits from external interfering signals.The cables are suitable for fixed installation in dry and wet premises as well as for outdoor installation on the walls ofbuildings , when require non-proliferation of flames.

I N S T R U M

E N T A T I O N A N D

C O N T R O L C A

B L E S

Cross section in mm2 0.5 0.75 1.3

Cond. resistance - max.Ω

/km 36.8 24.6 14.2

Mutual capacitance at800Hz- max. nF/km 55 60 70

Insulation resistance min 5GΩ .km

Max. conductor temperature 70∞—

Test voltage 50Hz, 1 min.wire - wire

wire - screen1500V1500V

Temperature rangemobilefixed

-5∞C to +50∞C-40∞C to +70∞C

Minimum bending radiusapprox 7.5 x cable diameter

Test Flame rerardant IEC 60502-1 IEC 60332-3klass C

Page 222: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 222/430

221

I N S T

R U ME N T A T I O N

A N D C O N T R O L C A B L E S

XLPE insulation pairs pairs stranded in layers static screen

sheath of PVC flame retardant

Construction data RE - 2XY(St)Y-fr

Number of pairsExternal diameter

approx. Copper weightCable weight

approx.

mm kg/km kg/km

Nx2x0.5mm2

1 7.5 14 782 8.2 23 974 11.0 42 1518 13.4 80 225

12 15.6 117 29716 17.3 155 36420 18.9 192 42924 20.3 230 49336 24.0 342 67948 27.0 455 857

Nx2x0.75mm21 8.0 90 202 8.7 115 334 12.0 180 598 14.7 280 111

12 17.2 365 16216 19.2 450 21520 21.0 555 26524 22.6 625 32036 26.8 860 47548 30.3 1090 630

Nx2x1.3mm2

1 6.7 35 652 9.9 60 1134 11.9 118 196

8 15.3 225 35012 18.2 335 49616 20.6 445 63820 22.7 558 77924 24.7 669 918

E L K A B E L

Page 223: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 223/430

Cable construction Technical data

Type codesRE control cable2X XLPE insulation(St) static screen

Yfr sheath of special PVC, flame-retardantPiMF screened pairs

Conductor bare copper conductoraccording to IEC 60228, nominal area:0.5mm2 = 7x 0.3 mm

1.3mm2

= 7x0.49mmInsulation XLPE according to IEC 60502-1Core Black/white with imprinted numbersidentification 1/1, 2/2 etc.Pairs each 2 wires are twisted to a pairPimf wrapping of plastic foilconstruction: drain wire 0.6 mm, tinned Cu, Al-PET

foil, metalside on the inside, foilwrapping

Cable core the pimf pairs are stranded intolayers with 1 orange communicationscore*

Wrapping several layers of plastic tapesScreen of aluminium tape one side

coated with polyester and 1

tinned copper wire 0.5mm2Sheath of PVC compound , flame-retardant

coloured black or other colour

222 E L K A B E L

RE-2X(St )Y - f r P iMF Similar to EN 50288

Application

These cables are used for data transfer in measuring and control appliancesThe screen of metal foil protects the circuits from external interfering signals.The cables are suitable for fixed installation in dry and wet premises as well as for outdoor installation on the walls ofbuildings , when require non-proliferation of flames

I N S T R U M

E N T A T I O N A N D

C O N T R O L C A

B L E S

Cross section in mm2 0.5 1.3

Cond. resistance - max.Ω/km

36.8 14.2

Mutual capacitance at800Hz- max. 120

Insulation resistance min. 5GΩ .km

Max. conductor temperature 70∞—

Test voltage 50Hz, 1 min.wire - wire

wire - screen1500V1500V

Cable rated voltage U0/U 300/300V

Temperature rangemobilefixed

-5∞C to +50∞C-40∞C to +70∞C

Minimum bending radius

approx 7.5 x cable diameterTest IEC 60502-1

Flame rerardant IEC 60332-3 class C

Page 224: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 224/430

223

I N S T

R U ME N T A T I O N

A N D C O N T R O L C A B L E S

XLPE insulation screened by pairs pairs stranded in layers static screen sheath of PVC flame retardant

Construction data RE - 2X(St)Y-fr

Number of pairs

External diameter

approx. Copper weight

Cable weight

approx.

mm kg/km kg/km

Nx2x0.5mm2

PiMF1 9.6 31 1052 11.7 36 1304 12.5 61 1718 14.7 122 248

12 17.7 165 355Nx2x1.3mm2

PiMF1 7.6 33 852 13.5 65 185

4 15.5 122 2758 20.2 232 460

12 21.5 352 599

E L K A B E L

Page 225: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 225/430

224 E L K A B E L

PVC/PVC Similar to BS 6346

Cable construction Technical data

Cable core construction

Application

These cables are preferentially used in outdoor applications, for indoor instalations, in the open air, underground and inwater where mechanical damage is not anticipated.

I N S T R U M

E N T A T I O N A N D

C O N T R O L C A

B L E S

Numberof wires

Centre First layer Second layer

4 4

8 1 7

12 2 9

16 f 5 11

20 f 7 13Type codes

PVC insulation or sheath of PVC

Conductor solid copper conductorto BS 6360

Conductor 1.00mm2 =1/1.13mm

size 1.50mm2 =1/1.38mmInsulation-material PVC type TI1 complying to

BS 7655-radialthickness,nom 0.6mmCable core the wires are stranded into layers

Wrapping minimum of 1 layer of plastic tape.Inner PVC compound type TM1Sheath complying to BS 7655, blackOuter PVC compound type TM1sheath complying to BS 7655Sheath orangecolour

Cross section in mm2: 1.0 1.5

Cond.resistance at 20oC

max.: Ω/km 18.1 12.1

Mutual capacitance at800Hz. max.nF/km 110 120

Insulation resistance min.ÃΩ .km 100 100

Test voltage 50Hz, 1 min.wire - wire 3500V

Temperature rangemobilefixed

-5∞C to +50∞C-30∞C to +70∞C

Minimum bending radiusapprox. 10 x cable diameter

Page 226: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 226/430

225

I N S T

R U ME N T A T I O N

A N D C O N T R O L C A B L E S

PVC insulation wires stranded in layers wraping PVCbedding sheath of PVC

Construction data PVC/PVC

Numberof wires

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm2 mm mm kg/km4x1.00 10.1 36 1408x1.00 12.4 72 218

12x1.00 14.6 108 30516x1.00 16.1 145 38520x1.00 17.4 180 4574x1.50 10.7 55 1658x1.50 13.4 108 267

12x1.50 15.5 162 37816x1.50 17.2 218 48020x1.50 18.7 270 575

Colour coding

Number of wires a-wire Number of wires a-wire Number of wires a-wire

1 red 8 orange 15 yellow/red2 white 9 grey 16 brown/red3 blue 10 violet 17 green/red4 black 11 white/red 18 orange/red5 green 12 blue/red 19 violet/red6 yellow 13 black/red 20 blue/ white7 brown 14 grey/red

E L K A B E L

Page 227: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 227/430

Cable construction Technical data

Cable core construction

Type codesPVC insulation or sheath of PVCSWA - galvanized steel wires armour

Conductor solid copper conductor to BS 6360Conductor 1.00mm2 =1/1.13mmsize 1.50mm2 =1/1.38mm

Insulation-material PVC type TI1 complying to

BS 7655-radialthickness,nom 0.6mmCable core the wires are stranded into layers

Wrapping minimum of 1 layer of plastic.tapeInner PVC compound type TM1Sheath complying to BS 7655, black

Armour single layer of galvanized steelwires complying to BS 1442

Outer PVC compound type TM1sheath complying to BS 7655Sheath colour orange

226 E L K A B E L

PVC /SWA/PVCSimilar to BS 6346

Application

These cables are preferentially used in outdoor applications, for indoor instalations, in the open air, underground and inwater where mechanical damage is anticipated.

I N S T R U M

E N T A T I O N A N D

C O N T R O L C A

B L E S

Cross section in mm2: 1.0 1.5

Cond.resistance at 20oCmax.: Ω/km 18.1 12.1

Mutual capacitance at800Hz. max.nF/km

120 140

Insulation resistance min.ÃΩ .km

100 100

Voltage rating: 600/1000V

Test voltage 50Hz, 1 min.wire - wire

wire - armour3500V3500V

Temperature rangemobilefixed

-5∞C to +50∞C-30∞C to +70∞C

Minimum bending radiusapprox. 15 x cable diameter

Numberof wires

Centre First layer Second layer

4 4

8 1 7

12 2 9

16 f 5 11

20 f 7 13

Page 228: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 228/430

227

I N S T

R U ME N T A T I O N

A N D C O N T R O L

C A B L E S

PVC insulation wires stranded in layers wraping PVC bed-ding armour sheath of PVC .

Colour coding

Number of wires a-wire Number of wires a-wire Number of wires a-wire

Construction data PVC/SWA/PVC

Numberof wires

Diameterof armour wire

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm2 mm mm kg/km kg/km4x1 0.9 11.9 36 2958x1 0.9 14.2 72 415

12x1 1.25 16.9 108 63616x1 1.25 18.6 145 74420x1 1.25 19.9 180 8554x1.5 0.9 12.5 55 3308x1.5 0.9 15.2 108 480

12x1.5 1.25 18.0 162 73516x1.5 1.25 19.7 218 87520x1.5 1.25 21.2 270 1010

1 brown 8 orange 15 grey/red2 yellow 9 red/white 16 black/red3 green 10 grey 17 violet/red4 red 11 red/blue 18 orange/red5 white 12 violet 19 green/red6 blue 13 brown/red 20 blue/ white7 black 14 yellow/red

E L K A B E L

Page 229: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 229/430

Cable construction Technical data

Conductor solid tinned copper conductordiameter 0.6 mm

Insulation PVC type TI1 complying to BS 6746;Nominal radial thickness - 0.2mm

Pair each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping minimum of 1 layer of plastic tape.Inner PVC compound type TM1sheath complying to BS 6746

Armour single layer of galvanized steelwires complying to BS 1442

Outer PVC compound type TM1sheath complying to BS 6746, black

Conductor diameter 0.6+/- 0.01mm

Cond.resistance at 20oC max.: 66MΩ.km

Insulation resistance min. 80MΩ.km

Mutual capacitance at 800Hz. max. 120nF/km

Capacitance unbalances at800Hz: K1 - maximum 270pF/500m

Test voltage 50Hz, 1 min.wire - wire

all wire - eart2000V5000V

Operating voltage peak value 150V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radiusapprox. 15 x cable diameter

228 E L K A B E L

PVC/PVC /SWA/PVC

x2x1 /0 .6

Similar to ESI 09-6, issue 5

Cable core construction

Application

These cables are preferentially used in outdoor applications, underground and where mechanical damage is not antici-pated.

— O M M

U N I C A T I O N A N

D C O N T R O L C A B L E

Numberof pairs

Number of pairs in centre and successive layers

First layer Second layer Third layer Fourth layer Fifth layer Sixth layer

2 2(quad)

5 5

10 2 6

20 1 8 13

30 4 10 16

50 4 10 15 21

100 2 8 14 20 25 31

Page 230: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 230/430

229

— O M

M U N I C A T I O N A

N D C O N T R O L C

A B L E

PVC insulation pairs stranded in layers PVC bedding

armour sheath of PVC

Color coding

Number of pair a-wire b-wire Number of pair a-wire b-wire

Construction data PVC/PVC/SWA/PVC x2x1/0.6

Number of pairsDiameter

of armour wireExternal diameter

approx.Copper weight

Cable weightapprox.

mm mm kg/km kg/km

2x2x1/0.6 0.9 8.3 11 1555x2x1/0.6 0.9 10.9 27 255

10x2x1/0.6 0.9 12.7 52 34020x2x1/0.6 0.9 15.4 105 50130x2x1/0.6 1.25 18.1 160 74850x2x1/0.6 1.25 21.8 265 1040

100x2x1/0.6 1.6 29.8 530 1948

1 black blue 51 black blue2 black orange 52 black orange3 black green 53 black green4 black brown 54 black brown5 black grey 55 black grey6 blue white 56 blue white7 blue orange 57 blue orange8 blue green 58 blue green9 blue brown 59 blue brown

10 blue grey 60 blue grey11 orange white 61 orange white12 orange green 62 orange green13 orange brown 63 orange brown14 orange grey 64 orange grey15 green white 65 green white16 green brown 66 green brown

17 green grey 67 green grey18 brown white 68 brown white19 brown grey 69 brown grey20 grey white 70 grey white21 black white 71 black white22 black red 72 black red23 black yellow 73 black yellow24 black violet 74 black violet25 white red 75 white red26 white yellow 76 white yellow27 white violet 77 white violet28 blue red 78 blue red29 blue yellow 79 blue yellow30 blue violet 80 blue violet31 green red 81 green red32 green yellow 82 green yellow33 green violet 83 green violet34 red grey 84 red grey35 red orange 85 red orange36 red yellow 86 red yellow37 red brown 87 red brown38 red violet 88 red violet39 grey yellow 89 grey yellow40 grey violet 90 grey violet41 orange yellow 91 orange yellow42 orange violet 92 orange violet43 yellow brown 93 yellow brown44 yellow violet 94 yellow violet45 brown violet 95 brown violet46 turquise black 96 turquise black47 turquise blue 97 turquise blue

48 turquise red 98 turquise red49 turquise orange 99 turquise orange50 turquise yellow 100 turquise yellow

E L K A B E L

Page 231: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 231/430

230 E L K A B E L

Similar to ESI 09-6, issue 5

Cable construction Technical data

Cable core construction

Application

These cables are preferentially used in outdoor applications, underground and where mechanical damage is not antici-pated.

— O M M

U N I C A T I O N A N

D C O N T R O L C A B L E

Number of pairs Centre First layer Second layer

2 2

5 510 2 815 5 10

20 1 6 13

Number of units 10x230 340 450 5

Conductor solid tinned copper conductordiameter 0.8 mm

Insulation PVC type TI1 complying toBS 6746

Pair each 2 wires are twisted to a pairCable core the pairs are stranded into layers or

units Wrapping minimum of 1 layer of plastic tape.

Inner PVC compound type TM1Sheath complying to BS 6746

Armour single layer of galvanized steelwires complying to BS 1442

Outer PVC compound type TM1sheath complying to BS 6746

Conductor diameter 0.8+/- 0.01mm

Cond.resistance at 20oC max.: 36.8MΩ.km

Insulation resistance min. 80MΩ.km

Mutual capacitance at800Hz. max. 150nF/km

Capacitance unbalances at800Hz: K1 - maximum 300pF/500m

Test voltage 50Hz, 1 min.wire - wire

all wire - eart2000V5000V

Operating voltage 150V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radiusapprox. 15 x cable diameter

Each unit is lappedwith coloured tape for identification as follows:

Unit 1 BlueUnit 2 OrangeUnit 3 GreenUnit 4 BrownUnit 5 Grey

Type codesPVC insulation or sheath of PVC

SWA armour

PVC/PVC /SWA/PVC

x2x1 /0 .8

Page 232: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 232/430

231

— O M

M U N I C A T I O N A

N D C O N T R O L C

A B L E

PVC insulation pairs stranded in layers or units PVCbedding armour sheath of PVC

Construction data PVC/PVC/SWA/PVC... x2x1/0.8

Numberof pairs

Diameterof armour wire

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm mm kg/km kg/km

2x2x0.8 0.9 9.5 19 1935x2x0.8 0.9 13.1 47 334

10x2x0.8 1.25 16.6 93 57220x2x0.8 1.25 20.6 186 83930x2x0.8 1.6 25.3 279 126140x2x0.8 1.6 27.7 372 150050x2x0.8 1.6 32.2 472 1874

Color coding

Number of pair a-wire b-wire Number of pair a-wire b-wire

1 white blue 11 black blue2 white orange 12 black orange3 white green 13 black green4 white brown 14 black brown5 white grey 15 black grey6 red blue 66 yellow blue7 red orange 17 yellow orange8 red green 18 yellow green9 red brown 19 yellow brown

10 red grey 20 yellow grey

2pair (quad cables) - white, red, blue, orange

E L K A B E L

Page 233: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 233/430

Cable construction Technical data

Conductor solid tinned copper conductordiameter 0.9 mm

Insulation PVC type TI1 complying to BS 6746;

Nominal radial thickness - 0.3mmPair each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping minimum of 1 layer of plastic tape.Inner PVC compound type TM1sheath complying to BS 6746

Armour single layer of galvanized steelwires complying to BS 1442

Outer PVC compound type TM1sheath complying to BS 6746, black

232 E L K A B E L

Standard: ESI 09-6, issue 5

Cable core construction

Application

These cables are preferentially used in outdoor applications, underground and where mechanical damage is not antici-pated..

— O M M

U N I C A T I O N A N

D C O N T R O L C A B L E

Numberof pairs

Number of pairs in centre and successive layers

First layer Second layer Third layer Fourth layer Fifth layer Sixth layer

2 2(quad)

5 5

10 2 6

15 5 10

20 1 6 13

25 2 8 15

30 4 10 16

50 4 10 15 21

75 3 9 15 21 27100 2 8 14 20 25 31

Conductor diameter 0.9+/- 0.01mm

Cond.resistance at 20oC max.: 29.67 MΩ.km

Insulation resistance min. 80MΩ.km

Mutual capacitance at 800Hz.max. 150nF/km

Capacitance unbalances at800Hz: K1 - maximum 400pF/500m

Test voltage 50Hz, 1 min.wire - wire

all wire - eart2000V5000V

Operating voltage peak value 150V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radiusapprox. 15 x cable diameter

PVC/PVC /SWA/PVC

x2x1 /0 .9

Page 234: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 234/430

233

— O M

M U N I C A T I O N A

N D C O N T R O L C

A B L E

PVC insulation pairs stranded in layers PVC bedding

armour sheath of PVC

Color coding

Number of pair a-wire b-wire Number of pair a-wire b-wire

Construction data PVC/PVC/SWA/PVC x2x1/0.9Numberof pairs

Diameterof armour wire

External diameterapprox.

Copper weight

Cable weightapprox.

mm mm kg/km kg/km2x2x1/0.9 0.9 9.7 24 2075x2x1/0.9 0.9 13.6 59 372

10x2x1/0.9 1.25 17.4 117 64115x2x1/0.9 1.25 19.5 177 79620x2x1/0.9 1.25 21.3 235 94625x2x1/0.9 1.6 23.9 294 124530x2x1/0.9 1.6 25.5 353 140140x2x1/0.9 1.6 28.2 471 1686

50x2x1/0.9 1.6 31.0 589 199575x2x1/0.9 2.0 37.0 442 2342

100x2x1/0.9 2.0 41.8 1201 3613

1 black blue 51 black blue2 black orange 52 black orange3 black green 53 black green4 black brown 54 black brown5 black grey 55 black grey6 blue white 56 blue white7 blue orange 57 blue orange8 blue green 58 blue green9 blue brown 59 blue brown

10 blue grey 60 blue grey11 orange white 61 orange white12 orange green 62 orange green13 orange brown 63 orange brown14 orange grey 64 orange grey15 green white 65 green white16 green brown 66 green brown

17 green grey 67 green grey18 brown white 68 brown white19 brown grey 69 brown grey20 grey white 70 grey white21 black white 71 black white22 black red 72 black red23 black yellow 73 black yellow24 black violet 74 black violet25 white red 75 white red26 white yellow 76 white yellow27 white violet 77 white violet28 blue red 78 blue red29 blue yellow 79 blue yellow30 blue violet 80 blue violet31 green red 81 green red32 green yellow 82 green yellow33 green violet 83 green violet34 red grey 84 red grey35 red orange 85 red orange36 red yellow 86 red yellow37 red brown 87 red brown38 red violet 88 red violet39 grey yellow 89 grey yellow40 grey violet 90 grey violet41 orange yellow 91 orange yellow42 orange violet 92 orange violet43 yellow brown 93 yellow brown44 yellow violet 94 yellow violet45 brown violet 95 brown violet46 turquise black 96 turquise black47 turquise blue 97 turquise blue48 turquise red 98 turquise red49 turquise orange 99 turquise orange50 turquise yellow 100 turquise yellow

E L K A B E L

Page 235: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 235/430

Cable construction Technical data

Conductor solid tinned copper conductordiameter 0.6 mm

Insulation PVC type TI1 complying to BS 6746

Nominal radial thickness - 0.2mmPair each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping minimum of 1 layer of plastic tape.Inner PVC compound type TM1sheath complying to BS 6746

Armour single layer of galvanized steelwires complying to BS 1442

Outer PE compound type HDPEsheath black

234 E L K A B E L

Similar to ESI 09-6, issue 5

Cable core construction

— O M M

U N I C A T I O N A N

D C O N T R O L C A B L E

Numberof pairs

Number of pairs in centre and successive layers

First layer Second layer Third layer Fourth layer Fifth layer Sixth layer

2 2(quad)

5 5

10 2 6

20 1 8 13

30 4 10 16

50 4 10 15 21

100 2 8 14 20 25 31

Application

These cables are preferentially used in outdoor applications, underground and where mechanical damage is not antici-pated.

Conductor diameter 0.6+/- 0.01mm

Cond.resistance at 20oC max.: 66 MΩ.km

Insulation resistance min. 80MΩ.km

Mutual capacitance at 800Hz.max. 120nF/km

Capacitance unbalances at800Hz: K1 - maximum 270pF/500m

Test voltage 50Hz, 1 min.wire - wire

all wire - eart2000V5000V

Operating voltage peak value 150V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radiusapprox. 15 x cable diameter

PVC/PVC /SWA/HDPE

x2x1 /0 .6

Page 236: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 236/430

235

— O M

M U N I C A T I O N A

N D C O N T R O L C A B L E

PVC insulation pairs stranded in layers PVC bedding

armour sheath of HDPE

E L K A B E L

Construction data PVC/PVC/SWA/HDPE x2x1/0.6

Numberof pairs

Diameterof armour wire

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm mm kg/km kg/km

2x2x1/0.6 0.9 8.3 11 1375x2x1/0.6 0.9 10.9 27 229

10x2x1/0.6 0.9 12.7 52 30320x2x1/0.6 0.9 15.4 105 446

30x2x1/0.6 1.25 18.1 160 67250x2x1/0.6 1.25 21.8 265 924100x2x1/0.6 1.6 29.8 530 1731

Color coding

Number of pair a-wire b-wire Number of pair a-wire b-wire

1 black blue 51 black blue2 black orange 52 black orange3 black green 53 black green4 black brown 54 black brown5 black grey 55 black grey6 blue white 56 blue white7 blue orange 57 blue orange8 blue green 58 blue green9 blue brown 59 blue brown

10 blue grey 60 blue grey11 orange white 61 orange white12 orange green 62 orange green13 orange brown 63 orange brown14 orange grey 64 orange grey15 green white 65 green white16 green brown 66 green brown

17 green grey 67 green grey18 brown white 68 brown white19 brown grey 69 brown grey20 grey white 70 grey white21 black white 71 black white22 black red 72 black red23 black yellow 73 black yellow24 black violet 74 black violet25 white red 75 white red26 white yellow 76 white yellow27 white violet 77 white violet28 blue red 78 blue red29 blue yellow 79 blue yellow30 blue violet 80 blue violet31 green red 81 green red32 green yellow 82 green yellow

33 green violet 83 green violet34 red grey 84 red grey35 red orange 85 red orange36 red yellow 86 red yellow37 red brown 87 red brown38 red violet 88 red violet39 grey yellow 89 grey yellow40 grey violet 90 grey violet41 orange yellow 91 orange yellow42 orange violet 92 orange violet43 yellow brown 93 yellow brown44 yellow violet 94 yellow violet45 brown violet 95 brown violet46 turquise black 96 turquise black47 turquise blue 97 turquise blue48 turquise red 98 turquise red49 turquise orange 99 turquise orange50 turquise yellow 100 turquise yellow

Page 237: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 237/430

Cable construction Technical data

Conductor solid copper conductordiameter 0.8 mm

Insulation PVC type TI1 complying to BS 6746Pair each 2 wires are twisted to a pairCable core the pairs are stranded into lears or units

Wrapping minimum of 1 layer of plastic tape.Screen of aluminium tape one side coated

with polyester and 1 solid tinned

copper wire with diameter 0.8mmInner PVC compound type TM1Sheath complying to BS 6746

Armour single layer of galvanized steelwires complying to BS 1442

Outer PVC compound type TM1sheath complying to BS 6746, black

236 E L K A B E L

ESI 09-6, issue 6

Cable core construction

Applications

These armoured and PVC insulated cables are utilized in electrical instrument circuits to provide communicationservices.

— O M M

U N I C A T I O N A N

D C O N T R O L C A B L E

Number of pairs Centre First layer Second layer

2 2

5 5

10 2 8

15 5 10

20 1 6 13

Number of units 10x2

30 3

40 4 1

50 5

Conductor diameter 0.8+/- 0.01mm

Cond.resistance at 20oC max.: 36.8MΩ.km

Insulation resistance min. 80MΩ.km

Mutual capacitance at 800Hz.max. 150nF/km

Capacitance unbalances at800Hz: K1 - maximum

400pF/500m

Test voltage 50Hz, 1 min.wire - wire

wire - screenall wire - eart

500V2000V5000V

Operating voltage 150VTemperature range

mobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radiusapprox. 15 x cable diameter

Each unit is lapped with coloured tape for identification as follows:

Unit 1 BlueUnit 2 Orange

Unit 3 GreenUnit 4 BrownUnit 5 Grey

Type codes

PVC insulation or sheath of PVCSWA - armourOSCR - screen of aluminium tape

PVC/OSCR /PVC/SWA/PVC

. . . x2x0 .8

Page 238: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 238/430

237

— O MM U N I C A T I O N A N D C O N T R O L C

A B L E

PVC insulation pairs stranded into units screen PVCbedding armour sheath of PVC

Color coding

Number of pair a-wire b-wire Number of pair a-wire b-wire

1 white blue 11 black blue2 white orange 12 black orange3 white green 13 black green4 white brown 14 black brown5 white grey 15 black grey6 red blue 16 yellow blue7 red orange 17 yellow orange8 red green 18 yellow green9 red brown 19 yellow brown

10 red grey 20 yellow grey

E L K A B E L

Construction data PVC/PVC/SWA/PVC... x2x1/0.8

Numberof pairs

Diameterof armour wire

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm mm kg/km kg/km

2x2x0.8 0.90 10.3 24 2275x2x0.8 0.90 13.7 51 382

10x2x0.8 1.25 17.0 98 61715x2x0.8 1.25 18.6 144 74120x2x0.8 1.25 20.8 191 89830x2x0.8 1.25 23.6 284 112540x2x0.8 1.60 26.8 377 152150x2x0.8 1.60 28.8 470 1742

2pair (quad cables) - white, red, blue, orange

Page 239: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 239/430

238 E L K A B E L

According to ESI 09-6, issue 6

Description Technical data

Application

H A L O G

E N - F R E E C O M

U N I C A T I O N A N

D C O N T R O L C

A B L E

Identification of cable pairs

Number of pair a-wire b-wire Number of pair a-wire b-wire

Conductor solid tinned copper conductordiameter 0.8 mm

Insulation of halogen free polymer compoundPair each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping minimum of 1 layer of plastic tape.Inner of halogen free polymer compoundsheath complying to BS 7655,part 6.1

Outer halogen free polymer compoundsheath complying to BS 7655,part 6.1

1 white blue 11 black blue2 white orange 12 black orange3 white green 13 black green4 white brown 14 black brown5 white grey 15 black grey6 red blue 16 yellow blue7 red orange 17 yellow orange8 red green 18 yellow green9 red brown 19 yellow brown

10 red grey 20 yellow grey

Conductor diameter 0.8+/- 0.01mm

Cond.resistance at 20oC max.: 36.8MΩ.km

Insulation resistance min. 100MΩ.km

Mutual capacitance at 800Hz.max. 150nF/km

Capacitance unbalances at800Hz: K1 - maximum

270pF/500m

Test voltage 50Hz, 1 min.wire - wire 2000V

Operating voltage 150V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radiusapprox. 15 x cable diameter

Unit 1 BlueUnit 2 OrangeUnit 3 GreenUnit 4 Brown

Unit 5 Grey

Type codes

LSZH - of halogen free polymer compound

These cables are preferentially used in outdoor applications, for indoor instalations, in the open air, underground,where a particular protection against fire and fire damage for human life and equipment is necessary.

2pair (quad cables) - white, red, blue, orange

LSZH/LSZH

. . . x2x1 /0 .8

Page 240: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 240/430

239L K A B E L

H A L O

G E N -F R E E C O

M U N I C A T I O N A

N D C O N T R O L C A B L E

LSZH insulation pairs stranded in layers LSZH bedding sheath of LSZH

Cable core construction

Mechanical data LSZH/LSZH ...x2x0.8

Numberof pairs

Externaldiameter approx.

Copper weight

Cable weight approx.

mm kg/km kg/km

1x2x0.8 7.1 10 652x2x0.8 7.9 19 855x2x0.8 11.3 47 165

10x2x0.8 14.3 93 26915x2x0.8 15.9 140 35020x2x0.8 18.1 188 45530x2x0.8 21.5 280 622

40x2x0.8 24.1 375 78850x2x0.8 28.0 470 966

Number of pairs Centre First layer Second layer

2 2

5 5

10 2 8

15 5 10

20 1 6 13

Number of units 10x2

3x10pair 5x10pair 2x20pair

30 1

40 1

50 1

Page 241: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 241/430

Description Technical data

Conductor solid tinned copper conductordiameter 0.9 mm

Insulation of halogen free polymer compoundPair each 2 wires are twisted to a pair

Cable core the pairs are stranded into layers Wrapping Minimum of 1 layer of plastic tape.Inner of halogen free polymer compoundsheath complying to BS 7655,part 6.1Outer halogen free polymer compoundsheath complying to BS 7655,part 6.1

Conductor diameter 0.9+/- 0.01mm

Cond.resistance at 20oC max.: 29.67 MΩ.km

Insulation resistance min. 100MΩ.km

Mutual capacitance at 800Hz.max. 150nF/km

Capacitance unbalances at800Hz: K1 - maximum

270pF/500m

Test voltage 50Hz, 1 min.wire - wire 2000V

Operating voltage 150V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radiusapprox. 15 x cable diameter

240 E L K A B E L

According to ESI 09-6, issue 5

Cable core construction

Application

These cables are preferentially used in outdoor applications, for indoor instalations, in the open air, underground,where a particular protection against fire and fire damage for human life and equipment is necessary.

H A L O G

E N - F R E E C O M

U N I C A T I O N A N

D C O N T R O L C

A B L E

Numberof pairs

Number of pairs in centre and successive layers

First layer Second layer Third layer Fourth layer Fifth layer Sixth layer

2 2(quad)

5 5

10 2 8

15 5 10

20 1 6 13

25 2 8 15

30 4 10 16

50 4 10 15 21

75 3 9 15 21 27

100 2 8 14 20 25 31

LSZH/LSZH

. . . x2x1 /0 .9

Page 242: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 242/430

H A L O

G E N

-F R E E C O

M U N I C A T I O N A N D C O N T R O L

C A B L E

241

LSZH insulation pairs stranded in layers LSZH bedding sheath of LSZH

Identification of cable pairs

Number of pair a-wire b-wire Number of pair a-wire b-wire

1 black blue 51 black blue

2 black orange 52 black orange3 black green 53 black green4 black brown 54 black brown5 black grey 55 black grey6 blue white 56 blue white7 blue orange 57 blue orange8 blue green 58 blue green9 blue brown 59 blue brown

10 blue grey 60 blue grey11 orange white 61 orange white12 orange green 62 orange green13 orange brown 63 orange brown14 orange grey 64 orange grey15 green white 65 green white16 green brown 66 green brown17 green grey 67 green grey

18 brown white 68 brown white19 brown grey 69 brown grey20 grey white 70 grey white21 black white 71 black white22 black red 72 black red23 black yellow 73 black yellow24 black violet 74 black violet25 white red 75 white red26 white yellow 76 white yellow27 white violet 77 white violet28 blue red 78 blue red29 blue yellow 79 blue yellow30 blue violet 80 blue violet31 green red 81 green red32 green yellow 82 green yellow33 green violet 83 green violet

34 red grey 84 red grey35 red orange 85 red orange36 red yellow 86 red yellow37 red brown 87 red brown38 red violet 88 red violet39 grey yellow 89 grey yellow40 grey violet 90 grey violet41 orange yellow 91 orange yellow42 orange violet 92 orange violet43 yellow brown 93 yellow brown44 yellow violet 94 yellow violet45 brown violet 95 brown violet46 turquise black 96 turquise black47 turquise blue 97 turquise blue48 turquise red 98 turquise red49 turquise orange 99 turquise orange

50 turquise yellow 100 turquise yellow

E L K A B E L

Mechanical data LSZH/LSZH ...x2x1/0.9

Number of pairsExternal diameter

approx.Copper weight

Cable weightapprox.

mm kg/km kg/km

2x2x1/0.9 8.30 24 995x2x1/0.9 11.8 59 188

10x2x1/0.9 14.9 117 30615x2x1/0.9 17.0 177 41820x2x1/0.9 18.8 235 51825x2x1/0.9 20.7 294 63030x2x1/0.9 22.3 353 73540x2x1/0.9 25.0 471 93350x2x1/0.9 28.8 589 117275x2x1/0.9 33.0 442 1099

100x2x1/0.9 37.8 1201 2188

Page 243: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 243/430

242 E L K A B E L

According to ESI 09-6,issue 6

Description Technical data

Cable core construction

Applications

H A L O G

E N - F R E E C O M

U N I C A T I O N A N

D C O N T R O L C

A B L E

Conductor solid tinned copper conductordiameter 0.8 mm

Insulation of halogen free polymer compoundPair each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping minimum of 1 layer of plastic tape.Inner of halogen free polymer compoundsheath complying to BS 7655,part 6.1

Armour single layer of galvanized steelwires complying to BS 1442Outer halogen free polymer compoundsheath complying to BS 7655,part 6.1

Conductor diameter 0.8+/- 0.01mmCond.resistance at 20oC max.: 36.8MΩ.km

Insulation resistance min. 100MΩ.km

Mutual capacitance at 800Hz.max. 150nF/km

Capacitance unbalances at800Hz: K1 - maximum 270pF/500m

Test voltage 50Hz, 1 min.

wire - wireall wire - eart 2000V5000VOperating voltage 150V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radiusapprox. 15 x cable diameter

Each unit is lappedwith coloured tape for identification as follows:

Unit 1 BlueUnit 2 OrangeUnit 3 GreenUnit 4 BrownUnit 5 Grey

Type codesLSZH - of halogen free polymer compoundSWA - armour

These armoured control and signal cables are utilized in industrial areas for installations provided with electronic con-trol or monitoring equipment, expecially when a high mechanical resistance is required.

Number of pairs Centre First layer Second layer

2 2

5 5

10 2 8

15 5 10

20 1 6 13

Number of units 10x2

3x10pair 5x10pair 2x20pair

30 1

40 1

50 1

LSZH/LSZH/SWA/LSZH

x2x1/0.8

Page 244: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 244/430

243L K A B E L

H A L O

G E N -F R E E C O

M U N I C A T I O N A

N D C O N T R O L C A B L E

LSZH insulation pairs stranded in layers LSZH bedding armour sheath ofLSZH

Mechanical data LSZH/LSZH/SWA/LSZH ...x2x0.8

Number of pairsDiameter

of armour wireExternal diameter

approx.Copper weight

Cable weightapprox.

mm mm kg/km kg/km

1x2x0.8 0.90 8.9 10 1672x2x0.8 0.90 10.1 19 2195x2x0.8 0.90 13.1 47 360

10x2x0.8 1.25 16.8 93 60515x2x0.8 1.25 18.4 140 72920x2x0.8 1.25 20.6 188 88530x2x0.8 1.25 24.0 280 112240x2x0.8 1.60 27.3 375 152050x2x0.8 1.60 31.2 470 1837

Identification of cable pairs

Number of pair a - wire b - wire Number of pair a - wire b - wire

1 white blue 11 black blue2 white orange 12 black orange3 white green 13 black green4 white brown 14 black brown5 white grey 15 black grey6 red blue 16 yellow blue7 red orange 17 yellow orange8 red green 18 yellow green9 red brown 19 yellow brown

10 red grey 20 yellow grey

2pair (quad cables) - white, red, blue, orange

Page 245: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 245/430

Description Technical data

Conductor solid tinned copper conductordiameter 0.9 mm

Insulation of halogen free polymer compoundPair each 2 wires are twisted to a pair

Cable core the pairs are stranded into layers Wrapping minimum of 1 layer of plastic tape.Inner of halogen free polymer compoundsheath complying to BS 7655,part 6.1

Armour single layer of galvanized steelwires complying to BS 1442

Outer halogen free polymer compoundsheath complying to BS 7655,part 6.1

Conductor diameter 0.9+/- 0.01mm

Cond.resistance at 20oC max.: 29.67 MΩ.km

Insulation resistance min. 100MΩ.km

Mutual capacitance at 800Hz.max. 150nF/km

Capacitance unbalances at800Hz: K1 - maximum

270pF/500m

Test voltage 50Hz, 1 min.wire - wire

all wire - eart2000V5000 V

Operating voltage 150V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radiusapprox.

15 x cable diameter

244 E L K A B E L

According to ESI 09-6,issue 5

Cable core construction

Applications

These armoured control and signal cables are utilized in industrial areas for installations provided with electronic con-trol or monitoring equipment, expecially when a high mechanical resistance is required.

H A L O G

E N - F R E E C O M

U N I C A T I O N A N

D C O N T R O L C

A B L E

Numberof pairs

Number of pairs in centre and successive layers

First layer Second layer Third layer Fourth layer Fifth layer Sixth layer

2 2(quad)

5 5

10 2 8

15 5 10

20 1 6 13

25 2 8 15

30 4 10 16

50 4 10 15 21

75 3 9 15 21 27

100 2 8 14 20 25 31

LSZH/LSZH/SWA/LSZH

x2x1 /0 .9

Page 246: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 246/430

245

H A L O

G E N -F R E E C O

M U N I C A T I O N A

N D C O N T R O L C A B L E

LSZH insulation pairs stranded in layers LSZH bedding armour sheath ofLSZH

Identification of cable pairs

Number of pair a - wire b - wire Number of pair a - wire b - wire

1 black blue 51 black blue

2 black orange 52 black orange3 black green 53 black green4 black brown 54 black brown5 black grey 55 black grey6 blue white 56 blue white7 blue orange 57 blue orange8 blue green 58 blue green9 blue brown 59 blue brown

10 blue grey 60 blue grey11 orange white 61 orange white12 orange green 62 orange green13 orange brown 63 orange brown14 orange grey 64 orange grey15 green white 65 green white16 green brown 66 green brown17 green grey 67 green grey

18 brown white 68 brown white19 brown grey 69 brown grey20 grey white 70 grey white21 black white 71 black white22 black red 72 black red23 black yellow 73 black yellow24 black violet 74 black violet25 white red 75 white red26 white yellow 76 white yellow27 white violet 77 white violet28 blue red 78 blue red29 blue yellow 79 blue yellow30 blue violet 80 blue violet31 green red 81 green red32 green yellow 82 green yellow33 green violet 83 green violet

34 red grey 84 red grey35 red orange 85 red orange36 red yellow 86 red yellow37 red brown 87 red brown38 red violet 88 red violet39 grey yellow 89 grey yellow40 grey violet 90 grey violet41 orange yellow 91 orange yellow42 orange violet 92 orange violet43 yellow brown 93 yellow brown44 yellow violet 94 yellow violet45 brown violet 95 brown violet46 turquise black 96 turquise black47 turquise blue 97 turquise blue48 turquise red 98 turquise red49 turquise orange 99 turquise orange

50 turquise yellow 100 turquise yellow

E L K A B E L

Mechanical data LSZH/LSZH/SWA/LSZH ...x2x1/0.9

Number of pairsDiameter

of armour wireExternal diameter

approx.Copper weight

Cable weightapprox.

mm mm kg/km kg/km

2x2x1/0.9 0.9 10.1 24 2155x2x1/0.9 0.9 13.6 59 372

10x2x1/0.9 1.25 17.4 117 63915x2x1/0.9 1.25 19.5 177 79220x2x1/0.9 1.25 21.3 235 94125x2x1/0.9 1.6 23.9 294 123830x2x1/0.9 1.6 25.5 353 1394

40x2x1/0.9 1.6 28.2 471 167650x2x1/0.9 1.6 32.0 589 200175x2x1/0.9 2.0 37.0 442 2332

100x2x1/0.9 2.0 41.8 1201 3582

Page 247: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 247/430

246 E L K A B E L

According to ESI 09-6,issue 6

Description Technical data

Cable core construction

H A L O G

E N - F R E E C O M

U N I C A T I O N A N

D C O N T R O L C

A B L E

Conductor solid tinned copper conductordiameter 0.8 mm

Insulation of halogen free polymer compoundPair each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping minimum of 1 layer of plastic tape.Screen of aluminium tape one side coated

with polyester and 1 solid tinned

copper wire with diameter 0.8mmInner of halogen free polymer compoundsheath complying to BS 7655,part 6.1

Armour single layer of galvanized steelwires complying to BS 1442

Outer halogen free polymer compoundsheath complying to BS 7655,part 6.1

Conductor diameter 0.8+/- 0.01mmCond.resistance at 20oC max.: 36.8MΩ.kmInsulation resistance min. 150MΩ.km

Mutual capacitance at 800Hz.max. 150nF/km

Capacitance unbalances at800Hz: K1 - maximum 270pF/500m

Test voltage 50Hz, 1 min.wire - wire

wire - screenall wire - eart

800V

1000V5000VOperating voltage 150V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Minimum bending radiusapprox. 15 x cable diameter

Each unit is lappedwith coloured tape for identification as follows:

Unit 1 BlueUnit 2 OrangeUnit 3 GreenUnit 4 BrownUnit 5 Grey

Type codesLSZH - of halogen free polymer compoundSWA - armourOSCR - screen of aluminium tape

Application

These armoured and LSZH insulated cables are utilized in electrical instrument circuits to provide communication serv-ices. They can be used in areas where fire could create dense smoke and toxic fumes.

Number of pairs Centre First layer Second layer

2 2

5 5

10 2 8

15 5 10

20 1 6 13

Number of units 10x2

3x10pair 5x10pair 2x20pair

30 1

40 1

50 1

LSZH /ŒSCR /LSZH /SWA/LSZH

x2x1 /0 .8

Page 248: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 248/430

247

H A L O

G E N -F R E E C O

M U N I C A T I O N A

N D C O N T R O L C A B L E

LSZH insulation pairs stranded in layers screen LSZH bedding armour Sheath of LSZH

Mechanical data LSZH/OSCR/LSZH/SWA/LSZH x2x0.8

Number of pairsDiameter

of armour wireExternal diameter

approx.Copper weight

Cable weightapprox.

mm mm kg/km kg/km

`1x2x0.8 0.90 9.1 14 1752x2x0.8 0.90 10.3 24 2305x2x0.8 0.90 13.3 52 365

10x2x0.8 1.25 17.0 99 62015x2x0.8 1.25 18.6 145 74520x2x0.8 1.25 20.8 192 89930x2x0.8 1.25 24.2 285 113940x2x0.8 1.60 27.5 380 153950x2x0.8 1.60 31.6 475 1870

Identification of cable pairs

Number of pair a-wire b-wire Number of pair a-wire b-wire

1 white blue 11 black blue2 white orange 12 black orange3 white green 13 black green4 white brown 14 black brown5 white grey 15 black grey6 red blue 16 yellow blue7 red orange 17 yellow orange8 red green 18 yellow green9 red brown 19 yellow brown

10 red grey 20 yellow grey

2pair (quad cables) - white, red, blue, orange

E L K A B E L

Page 249: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 249/430

Description Technical data

Core identification

Conductor bare copper conductor diameter0.8 mm

Insulation insulation of halogen - freepolymer compound type HI 1according to VDE 0207 part 23 ;thickness 0.3mm

Pairs each 2 wires are twisted to a pairBundle 4 pairs laid up to a bundleBundle by spirals imprinted numbersidentificationCable core bundles laid up in layers

Wrapping layers of polyester foilScreen braid of tinned Cu wiresSheath of halogen - free flame-retardant

polymer compound , type HM 2according to VDE 0207 part 24

Sheath grey or black

Cond. resistance at 20oC - max. 73.2 MΩ.km

Insulation resistance min. 100MΩ.kmMutual capacitance at 800Hz-

max. 120nF/km

Capacitance unbalances at800Hz: K1- max. 200pF/100m

Test voltage 50Hz, 1 min.wire - wire

wire - screen2000V5000V

Operating voltage, peak value 250V

Temperature rangemobilefixed

-5∞C ‰Ó +50∞C-30∞C ‰Ó +70∞C

Testing according to DIN VDE 0472 and IEC

Minimum bending radiusapprox. 7.5 x cable diameter

Flame testtest class C according toVDE 0472 part 804 and

IEC 332 - 3

248 E L K A B E L

Standard VDE 0815

H A L O G

E N - F R E E C O M

U N I C A T I O N A N

D C O N T R O L C

A B L E

Mechanical data JE-HCH ...x2x0.8 BD

No. of pairsConductor

Thickness ofthe sheath

Overalldiameterapprox.

LengthsType of drums

D/d/L*Copper weight

approx.Cable weight

approx.

mm mm mm m mm kg/km kg/km

2x2x0.8 1.4 7.4 1000 650/340/530 40 874x2x0.8 1.4 9.6 1000 800/450/530 73 1418x2x0.8 1.4 11.9 1000 1000/500/630 123 218

12x2x0.8 1.4 13.7 1000 1000/500/630 173 291

40x2x0.8 1.6 22.1 1000 1400/750/880 481 751

Application

Safety installation cables are used for the transmission of signals and measuring datas in control circuits, where a par-

ticular protection against fire and fire damage for human life and equipment is necessary. Installation cables are notadmissible for power installation purposes and direct burial.

Identification of the cores by the colours of the insulation which are repeated in the same manner in each bundle.

Colours of the pairsPair 1 2 3 4

Core a b a b a b a b

Colour blue red grey yellow green brown white black

Cables with 2 pairs laid up as a star quad.

Each bundle identified by open support spiral with imprinted numbers.

Note : D - flange diameter; d - core diameter; L - overall width

Pairs laid up in bundles with copper braid screen

J E - H C H . . . x 2 x 0 . 8 B D

Page 250: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 250/430

H A L O

G E N -F R E E C O

M U N I C A T I O N A

N D C O N T R O L C A B L E

Colours of the pairs

249L K A B E L

pair 1 2 3 4

Core a b a b a b a b

Basic colour blue red grey yellow green brown white black

Description Technical data

Conductor plain Cu wires, flexibleConstruction 0.5mm2 = 7x0.3of conductorInsulation core insulation of halogen-free

polymer compound HI 2 according toVDE 0207,part 23

Core according to VDE 0815identificationPair 2 cores twisted to a pairBundle 4 pairs laid up to a bundleType of lay-up Bundles laid up in layers

Wrapping plastic foil overlapping

Screen braid of tinned copper wiresSheath of halogen-free flame-retardantpolymer compound type HM2 according to VDE 0207 part 24

Sheath colour Grey or black

Cross section in : 0.5 mm2

Cond. resistance at 20oC max: 78.4 Ω/km

Insulation resistance min.: 100MΩ.km

Operating capacitance at800Hz: max.: 120 1) nF/km

Capacitance unbalances at800Hz max.: 200 2) pF/100m

Test voltage, effective value,50Hz

core/core

core/screen

500V

2000VOperating voltage, peak

value : 225V

Temperature rangemobilefixed

-5oC to +50oC-30oC to +70oC

Minimum bending radiusBending once withouttensile force:Multiple

bending with tensile force2.5 x cable diameter7.5 x cable diameter

Caloric load/flame test: test class C according to VDE0472 part 804 and IEC 332-3

Halogen-free properties : according to VDE 0472 part813 and IEC 754-1

Smoke density : according to VDE 0472 part816

According to VDE 0815

Application

Halogen-free installation cables with copper screen are used for telecommunications and information processing sys-tems in environments susceptible to interference and for higher requirements on the signal transmission characteristicsfor optimum data transmissions. The overall braided screen of tinned copper wires provides against external and elec-tromagnetic interference and ensures a perfect data transmission. These cables are also suitable for flexible and per-manent installation in dry rooms. The use of installation cables for power cable applications and underground installa-tion is not permitted.

Halogen-free insulation pairs laid up in bundles with copper braid screen halogen-free sheath

Mechanical data JE-LiHCH...x2x0.5 mm2

Number of pairsExternal diameter

approx.Copper weight

Cable weightapprox.

mm kg/km kg/km

2 7.7 42 954 10.4 77 1618 12.6 124 247

12 14.9 176 33816 16.6 223 42120 18.5 272 520

24 19.9 314 59732 22.3 402 75040 24.8 491 92680 33.6 916 1691

1)The value may be exceeded by 20% by cables with up to4 pairs.2) 20% of the values, min. one value up to 400pFpermitted.

Type codesJE - cable for industrial electronicsLi - stranded wire conductorH - insulation or sheath of halogen-free compoundC - screen of copper wire braid

Bundle: 4 pairs laid up to a bundle; Bundle identification: eachbundle identified by open support spiral with imprinted numbersMethod of counting: starting at the inner layer with no.1 andcounting successively outwards in the same manner througheach layerCables with 2 pairs laid up as a star quad: winding 1: a-coreblue; b-core redwinding 2: a-core grey; b-core yellow

. . .x 2 x 0 . 5 m m 2

Page 251: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 251/430

Description Technical data

Conductor solid copper conductor,diameter 0.8mm

Insulation PE insulation type 03Caccording to BS 6234

Pairs each 2 wires are twisted to apair

Cable core the pairs are stranded intolayers

Wrapping several layers of plastic tapesInner of PE compound type 03Csheath according to BS 6234

Armour single layer of galvanized steelwires complying to BS 1442

Outer of PE compound type 03Csheath according to BS 6234

coloured black

Conductor diameter 0.8mmCond. resistance at 20∞C, max. : 73.6MΩ.km

Mutual capacitance at1000Hz -max. 5 GΩ.km

Insulation resistance at 20∞C, min. 50nF/kmCapacitance unbalances at

1000Hz - max. 500pF/500m

Test voltage AC for 1 min.

between each conductor &earth 5 kVMutual inductance at 5 kHz,

max: 0.5 mH/100m

Attenuation dB/km:

at 300 Hzat 1000Hzat 2000Hzat 3000Hzat 4000Hz

Characteristic impedance:at 1000Hzat 10 kHz

Induced voltageUpto 5kv :

0.510.911.251.501.68

550Ω200Ω

Minimum bending radiusapprox. 15 x cable diameter

250

According to ESI 09-6, issue 3

Application

These cables are used for control, protection, signalling, telecommunications, and data transmission purpores associ-ated with power distribution and transmission systems.

C O

N T R O L C A B L E F O R I N D U C E D V

O L T A G E U P T O

5 K V

E L K A B E L

Cable core construction

Number of pairsNumber of pairs in centre and successive layers

First layer Second layer Third layer Fourth layer

4 4

7 1 6

19 1 6 12

37 6 12 18

PE/PE /SWA/PE

. . . x2x1 /0 .8

Page 252: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 252/430

251

C O N T

R O L C A B L E F O

R I N D U C E D V O

L T A G E U P T O

5

K V

PE insulation pairs stranded in layer PE bedding armour sheath of PE

Colour coding

Pair no. a - wire b - wire

1 red yellow2 black violet3 orange grey4 green brown5 orange blue6 green brown7 orange white8 black violet9 red yellow

10 green brown11 red yellow12 green brown13 red yellow14 green brown15 red yellow16 green brown

17 red yellow18 green brown19 blue white20 black violet21 red yellow22 green brown23 red yellow24 green brown25 red yellow26 green brown27 red yellow28 green brown29 red yellow30 green brown31 red yellow32 green brown

33 red yellow34 green brown35 red yellow36 green brown37 blue white

E L K A B E L

Mechanical data PE/PE/SWA/PE ...x2x1/0.8

Number of pairsDiameter

of armour wireExternal diameter

approx.Copper weight

Cable weightapprox.

mm mm kg/km kg/km4 0.9 14.1 38 3257 0.9 16.1 66 410

19 1.60 24.4 179 105037 1.60 31.0 345 1570

Page 253: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 253/430

Description Technical data

Conductor solid copper conductor,diameter 0.8mm

Insulation PE insulation type 03C

according to BS 6234Pairs each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping several layers of plastic tapesInner of PE compound type 03Csheath according to BS 6234

Armour single layer of galvanized steelwires complying to BS 1442

Outer of PE compound type 03Csheath according to BS 6234

coloured black

252

According to ESI 09-6, issue 3

Application

These cables are used for control, protection, signalling, telecommunications, and data transmission purpores associ-ated with power distribution and transmission systems.

C O N T R O L C A B L E F O

R I N D U C E D V O

L T A G E U P T O 1

5 K V

E L K A B E L

Cable core construction

Conductor diameter : 0.8mmCond. resistance at 20∞C, max. : 73.6MΩ.km

Mutual capacitance at1000Hz - max. 5 GΩ.km

Insulation resistance at20∞C, min. 40nF/km

Capacitance unbalances at1000Hz - max. 500pF/500m

Test voltage AC for 1 min.between each conductor &

earth 15 kVMutual inductance at 5kHz,

max: 0.5 mH/100m

Attenuation dB/km:

ÔË 300 HzÔË 1000HzÔË 2000HzÔË 3000HzÔË 4000Hz

Characteristic impedance:

ÔË 1000HzÔË 10 kHz

Induced vo l tage5kv - 15kv :

0.480.851.151.401.55

550Ω200ΩMinimum bending radius

approx. 15 x cable diameter

Number of pairsNumber of pairs in centre and successive layers

First layer Second layer Third layer Fourth layer

4 4

7 1 6

19 1 6 12

37 6 12 18

PE/PE /SWA/PE

. . . x2x1 /0 .8

Page 254: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 254/430

253

C O N T

R O L C A B L E F O

R I N D U C E D V O

L T A G E U P T O

1

5 K V

PE insulation pairs stranded in layers PE bedding armour sheath of PE

Colour coding

Pair no. a - wire b - wire

1 red yellow2 black violet3 orange grey4 green brown5 orange blue6 green brown7 orange white8 black violet9 red yellow

10 green brown11 red yellow12 green brown13 red yellow14 green brown15 red yellow16 green brown

17 red yellow18 green brown19 blue white20 black violet21 red yellow22 green brown23 red yellow24 green brown25 red yellow26 green brown27 red yellow28 green brown29 red yellow30 green brown31 red yellow32 green brown

33 red yellow34 green brown35 red yellow36 green brown37 blue white

E L K A B E L

Mechanical data PE/PE/SWA/PE ...x2x1/0.8

Number of pairsDiameter

of armour wireExternal diameter

approx.Copper weight

Cable weightapprox.

mm mm kg/km kg/km

4 1.25 19.2 38 5807 1.25 21.6 66 720

19 1.60 31.1 179 143037 2.00 40.4 348 2399

Page 255: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 255/430

Description Technical data

Conductor solid copper conductor,diameter 0.8mm

Insulation PE insulation type 03C

according to BS 6234Pairs each 2 wires are twisted to a

pairCable core the pairs are stranded into

layers Wrapping several layers of plastic tapesInner of PE compound type 03Csheath according to BS 6234

Armour single layer of galvanized steelwires complying to BS 1442

Outer of PVC compound type TM1sheath according to BS 7655,

coloured black

254

According to ESI 09-6, issue 3

Application

These cables are used for control, protection, signalling, telecommunications, and data transmission purpores associ-ated with power distribution and transmission systems..

C O

N T R O L C A B L E F O R I N D U C E D V

O L T A G E U P T O

5 K V

E L K A B E L

Cable core construction

Conductor diameter : 0.8mmCond. resistance at 20∞C max. 73.6MΩ.km

Mutual capacitance at1000Hz -max. 5 GΩ.km

Insulation resistance at20∞C, min. 50nF/km

Capacitance unbalances at1000Hz - max. 500pF/500m

Test voltage AC for 1 min.between each conductor &

earth 5 kVMutual inductance at 5kHz,

max: 0.5 mH/100m

Attenuation dB/km:

ÔË 300 HzÔË 1000HzÔË 2000HzÔË 3000HzÔË 4000Hz

Characteristic impedance:

ÔË 1000HzÔË 10 kHz

Induced voltageUpto 5kv

0.510.911.251.501.68

550Ω200Ω

Minimum bending radiusapprox. 15 x cable diameter

Number of pairsNumber of pairs in centre and successive layers

First layer Second layer Third layer Fourth layer

4 4

7 1 6

19 1 6 12

37 6 12 18

PE / PE / SWA / PV C

. . . x2x1 /0 .8

Page 256: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 256/430

255

C O N T

R O L C A B L E F O

R I N D U C E D V O

L T A G E U P T O

5

K V

PE insulation pairs stranded in layer PE bedding armour sheath of PVC

Colour coding

Pair no. a - wire b - wire

1 red yellow2 black violet3 orange grey4 green brown5 orange blue6 green brown7 orange white8 black violet9 red yellow

10 green brown11 red yellow12 green brown13 red yellow14 green brown15 red yellow16 green brown

17 red yellow18 green brown19 blue white20 black violet21 red yellow22 green brown23 red yellow24 green brown25 red yellow26 green brown27 red yellow28 green brown29 red yellow30 green brown31 red yellow32 green brown

33 red yellow34 green brown35 red yellow36 green brown37 blue white

E L K A B E L

Mechanical data PE/PE/SWA/PVC ...x2x1/0.8

Number of pairsDiameter

of armour wireExternal diameter

approx.Copper weight

Cable weightapprox.

mm mm kg/km kg/km

4 0.9 14.1 38 360

7 0.9 16.1 66 45019 1.60 24.4 179 111037 1.60 31.0 345 1660

Page 257: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 257/430

Description Technical data

Conductor solid copper conductor,diameter 0.8mm

Insulation PE insulation type 03C

according to BS 6234Pairs each 2 wires are twisted to a pairCable core the pairs are stranded into layers

Wrapping several layers of plastic tapesInner of PE compound type 03Csheath according to BS 6234

Armour single layer of galvanized steelwires complying to BS 1442

Outer of PVC compound type TM1sheath according to BS 7655,

coloured black

256

According to ESI 09-6, issue 3

Application

These cables are used for control, protection, signalling, telecommunications, and data transmission purpores associ-ated with power distribution and transmission systems.

C O N

T R O L C A B L E F O R I N D U C E D V O

L T A G E U P T O

1 5 K V

E L K A B E L

Cable core construction

Conductor diameter : 0.8mmCond. resistance 20∞C max. 73.6MΩ.km

Mutual capacitance at1000Hz -max. 5 GΩ.km

Insulation resistance at20∞C, min. 40nF/km

Capacitance unbalances at1000Hz - max. 500pF/500m

Test voltage AC for 1 min.between each conductor &

earth 15 kVMutual inductance at 5kHz,

max: 0.5 mH/100m

Attenuation dB/km:

ÔË 300 HzÔË 1000HzÔË 2000HzÔË 3000HzÔË 4000Hz

Characteristic impedance:ÔË 1000HzÔË 10 kHz

Induced voltage5kv - 15kv:

0.480.851.151.401.55

550Ω200Ω

Minimum bending radiusapprox. 15 x cable diameter

Number of pairsNumber of pairs in centre and successive layers

First layer Second layer Third layer Fourth layer

4 4

7 1 6

19 1 6 12

37 6 12 18

PE / PE / SWA / PV C

. . . x2x1 /0 .8

Page 258: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 258/430

257

C O N T

R O L C A B L E

F O

R I N D U C E D

V O L T A G E

U P

T O 1

5 K V

PE insulation pairs stranded in layer PE bedding armour sheath of PVC

Colour coding

Pair no. a - wire b - wire

1 red yellow2 black violet3 orange grey4 green brown5 orange blue6 green brown7 orange white8 black violet9 red yellow

10 green brown11 red yellow12 green brown13 red yellow14 green brown15 red yellow16 green brown

17 red yellow18 green brown19 blue white20 black violet21 red yellow22 green brown23 red yellow24 green brown25 red yellow26 green brown27 red yellow28 green brown29 red yellow30 green brown31 red yellow32 green brown

33 red yellow34 green brown35 red yellow36 green brown37 blue white

E L K A B E L

Mechanical data PE/PE/SWA/PVC ...x2x1/0.8

Number of pairsDiameter

of armour wireExternal diameter

approx.Copper weight

Cable weightapprox.

mm mm kg/km kg/km

4 1.25 19.2 38 6657 1.25 21.6 66 820

19 1.60 31.1 179 166037 2.00 40.4 348 2780

Page 259: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 259/430

Description Technical data

Conductor solid copper conductor,diameter 0.8mm

Insulation PE insulation type 03Caccording to BS 6234

Pairs each 2 wires are twisted to a pairCable core the pairs are stranded into layersFiling petroleum - based jelly

Wrapping several layers of plastic tapesInner of PE compound type 03Csheath according to BS 6234

Armour single layer of galvanized steelwires complying to BS 1442

Outer of PVC compound type TM1sheath according to BS 7655,

coloured black

258

ESI 09-6, issue 3

Application

These cables are used for control, protection, signalling, telecommunications, and data transmission purpores associ-ated with power distribution and transmission systems..

C O N

T R O L C A B L E F O R

I N D U C E D

V O

L T A G E

U P

T O

1 5 K V

E L K A B E L

Cable core construction

Conductor diameter : 0.8mmCond. resistance at 20∞C max. 73.6MΩ.km

Mutual capacitance at1000Hz -max 5 GΩ.kmInsulation resistance at

20∞C, min. 40nF/km

Capacitance unbalances at1000Hz - max. 500pF/500m

Test voltage AC for 1 min.between each conductor &

earth 15 kVMutual inductance at 5kHz,

max: 0.5 mH/100m

Attenuation dB/km:

ÔË 300 HzÔË 1000HzÔË 2000HzÔË 3000HzÔË 4000Hz

Characteristic impedance:ÔË 1000HzÔË 10 kHz

Induced voltage5kv - 15kv:

0.510.911.251.501.68

550Ω200ΩMinimum bending radius

approx. 15 x cable diameter

Number of pairsNumber of pairs in centre and successive layers

First layer Second layer Third layer Fourth layer

4 4

7 1 6

19 1 6 12

37 6 12 18

PE /PJF /PE /SWA/PVC

. . . x2x1 /0 .8

Page 260: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 260/430

C O N T

R O L C A B L E

F O

R I N D U C E D

V O L T A G E

U P

T O 1

5 K V

259

PE insulation pairs stranded into layer jelly filling PE bedding armour sheath of PVC

Colour coding

Pair no. a - wire b - wire

1 red yellow2 black violet3 orange grey4 green brown5 orange blue6 green brown7 orange white8 black violet9 red yellow

10 green brown11 red yellow12 green brown13 red yellow14 green brown15 red yellow16 green brown

17 red yellow18 green brown19 blue white20 black violet21 red yellow22 green brown23 red yellow24 green brown25 red yellow26 green brown27 red yellow28 green brown29 red yellow30 green brown31 red yellow32 green brown

33 red yellow34 green brown35 red yellow36 green brown37 blue white

E L K A B E L

Mechanical data PE/PJF/PE/SWA/PVC ...x2x1/0.8

Number of pairsDiameter

of armour wireExternal diameter

approx.Copper weight

Cable weightapprox.

mm mm kg/km kg/km

4 1.25 19.2 38 6627 1.25 21.6 66 820

19 1.60 31.1 179 165237 2.00 40.4 345 2780

Page 261: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 261/430

260

BS 6346/87

PE insulation wires stranded in layers sheath of PE

Description Technical data

Application

For electrical instalations

L O

O P

F E E D E R

C A

B L E S

Mechanical data PE/PE

Number of wiresExternal diameter

approx.Copper weight

Cable weightapprox.

mm kg/km kg/km

2x1.5mm2 8.1 27 644x1.5mm2 9.1 54 1022x2.5mm2 9.1 43 884x2.5mm2 10.5 88 146

Conductor solid copper conductor to BS 6360Conductor 1.50mm2 =1/1.37mmsize 2.50mm2 =1/1.78mmInsulation PE type 03 complying to BS 6234-radialthickness, nom 0.6mmCable core 2 x N mm2 - pair

4 x N mm2 - quad Wrapping minimum of 1 layer of plastic tape

Outer PE compound type 03sheath complying to BS 6234Sheath orangecolour

Cross section in mm2: 1.5 2.5Cond.resistance at 20∞C max. 12.1Ω.km 7.41Ω.km

Insulation resistance min. 5Ω.km 5Ω.km

Mutual capacitance at 800Hzmax. nF/km:

2x1.5 4x1.5; 2x2.5 4x2.552-42-55-45

Inductance µH/km 505- 685- 490- 670

Test voltage 50Hz, 1 min.wire - wire 3500V

Voltage rating: 600/1000 VTemperature range

mobilefixed

-20∞C ‰Ó +50∞C‰Ó +70∞C

Minimum bending radiusapprox. 6 x cable diameter

Color coding

Number of wires a-wire b-wire c-wire d-wire

1 blue brawn

2 blue brawn black grey

Type codes2Y insulation or sheath of PE

E L K A B E L

PE/PE

Page 262: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 262/430

Technical data

261

L O O P

F E E D E R

C A B L E

S

Cross section in mm2 : 1.5 2.5

Cond.resistance at 20∞C max. 12.1Ω.km 7.41Ω.km

Insulation resistance -min. 5Ω.km

Mutual capacitance at 800Hzmax. nF/km:

2x1.5 4x1.5; 2x2.5 4x2.562-52-62-452

Inductance µH/km 505- 685- 490- 670

Test voltage 50Hz, 1 min.

wire - wirewire - armour 3500V3500V

Voltage rating: 600/1000 VTemperature range

mobilefixed

-20∞C ‰Ó +50∞C‰Ó +70∞C

Minimum bending radiusapprox 7.5 x cable diameter

BS 6346/87

PE insulation wires stranded in layers PE bedding armour sheath of PE

Description

Application

These cables are preferentially used in outdoor applications, for indoor instalations, in the open air and undergroundwhere mechanical damage is anticipated.

Conductor solid copper conductor to BS 6360Conductor 1.50mm2 =1/1.37mmsize 2.50mm2 =1/1.78mmInsulation BS 6234materialCable core 2 x N mm2 - pair

4 x N mm2 - quad Wrapping minimum of 1 layer

of plastic tapeInner Sheath PE type 03 complying to

BS 6234, natural Armour single layer of galvanizedsteel wires complying toBS1442

Outer PE compound type 03sheath complying to BS 6234Colour orange

Color coding

Number of pair a-wire b-wire c-wire d-wire

1 blue brawn

2 blue brawn black grey

Type codes2Y insulation or sheath of PESWA - armour

E L K A B E L

Mechanical data PE/SWA/PE

Number of wiresDiameter

of armour wireExternal diameter

approx.Coppe rweight

Cable weightapprox.

mm mm kg/km kg/km

2x1.5mm2 0.9 11.4 27 2304x1.5mm2 0.9 12.5 54 2952x2.5mm2 0.9 12.5 43 2904x2.5mm2 0.9 14.0 88 370

PE /SWA/PE

Page 263: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 263/430

C O N D U

C T O R S

E L K A B E L

Page 264: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 264/430

C O N D U C T O R S

E L K A B E L

Page 265: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 265/430

Construction data H05V-U/-K 300/500V

Nominal cross section Approx. outer diameter Copper weight Approx.

cable weight

mm2

mm kg/Ím kg/km

264

C O N D U C T O

R S

F O R

E L E C T

R I C

I N S T A L L A T

I O N S

H05V-U / -KUo/U - 300/500V

VDE 0281-3 andBDS HD 21.3 S3Cu conductors PVC insulation

Cable construction

Conductor copper wires,according toVDE 0295 class 1 or 5 (IEC 60228)

Insulation: PVC, compound Type YI1according to VDE 0207 part 4

Color black, red, blue, pink, gray, yellow,green, brown, white, violet, orange

Two-color combinations are not

permitted except for green/yellow.

Technical data

Applications

H05V-U/-K PVC-insulated wiring cable according to VDE 0281 part 3,HD 21.3 S3 and IEC 60227-3. These flexible PVC -insulated wiring cables are used for the internal wiring of equipment as well as for protected installation in and to light-

ing fixtures, in tubes, in conduit, on and under plaster although only for bell circuits and signal systems.

HO5V-U, , , ,, , , ,, , , ,

HO5V-K, , , ,, , , ,, , , ,

Conductor resistanceat 20OC

VDE IEC

Core temperature, max: C p

Rated voltage Uo/U / V

Test voltage AC, 50 Hz:: V

Temperature::f:

- C + C- C + C

Bending radius up to10mm diameter

>10mm diameter

Flame test:s ss B

VDE p IEC -

E L K A B E L

Page 266: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 266/430

Construction data H07V-U/-R/-K 450/750V

Nominal cross section Approx. outer diameter Copper weight Approx.

cable weight

mm2

mm kg/Ím kg/km

265

C O N

D U C T O R S

F O R

E L E C T R I C

I N S T

A L L A T I O N S

Uo/U - 450/750 V VDE 0281-3 andBDS HD 21.3.S3 Cu conductors PVC insulation

Applications

H07V-U/-R/-K PVC-insulated single-core cable according to VDE 0281 part 3,HD 21.3 S3 and IEC 227-3. These PVC-insulated single-core cables are used for the internal wiring of equipment switching systems and distributors as well as

for the protected installation in and to lighting fixtures with a rated voltage up to 1000 V alternating current or a directvoltage up to 750 V, earthed.These cables are suitable for installation in dry rooms, switching and distribution systems,in conduit, on, in and under plaster as well as in closed installation ducts.Note (for H07V): These single-core cables may not be used for direct installation on flatbed bodies, ducts or tanks.

Approved for use as potential-compensating cable directly on, in and underneath plaster as well as on flatbed bodies or similar.

H07V-U/ -R / -K

Cable construction

Conductor copper wires,according toVDE 0295 class 1, 2 or 5 (IEC 60228)

Insulation: PVC, compound Type YI1 accordingto VDE 0207 part 4

Color black, red, blue, pink, gray, yellow,green, brown, white, violet, orange

Two-color combinations are notpermitted except for green/yellow.

Technical data

Conductor resistance at 20oC VDE IEC

Core temperature, max: C p

Rated voltage Uo/U / V

Test voltage AC, 50 Hz: V

Temperature range:f:

- C + C- C + C

Bending radius up to

>

Flame test:s ss B VDE p

IEC -

HO7V-U , , , , ,

, HO7V-R

, , , , ,

, , , , ,

E L K A B E L

Page 267: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 267/430

266

C O N D U C T O

R S

F O R

E L E C T

R I C

I N S T A L L A T

I O N S

H07V-U/-R/-KUo/U - 450/750 V

VDE 0281-3 and BDS HD 21.3.S3Cu conductors PVC insulation

Construction data H07V-U/-R/-K 450/750V

Nominal cross section Approx. outer diameter Copper weight Approx.

cable weight

mm

2

mm kg/Ím kg/km , ,

, , , , , ,

HO7V-K, , , ,

, ,

,

, , , , , ,

, , , ,

E L K A B E L

Page 268: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 268/430

267

C O N

D U C T O R S

F O R

E L E C T R I C

I N S T

A L L A T I O N S

Cable construction

Construction According to VDE 0250 - 201

Conductor copper wires according to VDE 0295class1 (IEC 60228)

Insulation PVC ,compound type YI 1 according toVDE 0207 part 4

Cores flat in adjacent configuration with a common cover-ing of PVC compound

Sheath PVC ,compound type YM 1according to VDE 0207 part 5

Color white, black, gray

Uo/U - 230/400 V VDE 0250 part 201

Cu conductors PVC insulation PVC sheath

Technical data

Applications

For installation in dry environments only, both in and beneath plaster. The cables must be covered by plaster alongtheir entire length. Installation in cavities of concrete, stone or non-inflammable building materials is allowed.Installations notes:

- T s s f s, s s s- F , s p s s p f f s, ps ps, ss, s s ss

- F s s s ps f s ssq f s ps ps- T s B f s s ps f qps s s s

Color coding

NYIFY

Conductor resistance at 20oC according to VDE 0295 Class1 andIEC 228 Class1

Core temperature, max: C p

Rated voltage Uo/U / V

Test voltage AC, 50 Hz V

Temperature range - C + C

Minimum bending radius f s

Testing DIN VDE

Flame test s ss B VDE p IEC -I

Number of core W / W /2 core - , 3 core / , , , , 4 core / , , , , , , 5 core / , , , , , , , ,

Construction data NYIFY 230/400VNumber of wires and nominal

cross sectionOuter dimensions

approx. Copper weight Approx.cable weight

mm2 mm kg/Ím kg/km

NYIFY - O, , , , ,

NYIFY - J, , , , , , , , , ,

, , ,

E L K A B E L

Page 269: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 269/430

Construction data H03VV-F/H03VVH2-F 300/300V

Number of wires and nominalcross section Approx. outer diameter Copper weight

Approx.cable weight

mm2 mm kg/Ím kg/km

Cable construction

Conductor copper wires according toVDE 0295 Class 5and IEC 60228 Class 5

Insulation: PVC, compound Type TI2 ,according to VDE 0207 part 4

Sheath PVC, compound type TM2according to VDE 0207 part 5

Color: black or white as standard color,

Different colors available upon request.

Technical data

268

Applications

H03VV-F PVC-insulated sheathed cable according to VDE 0281 part 5,HD 21.5 S3 and IEC 227-5.The cables are suitable for connection of light small duty appliances, i. e. desk-instructions of the lamps, fairy-lamps,house vacuum cleaners, radio sets etc. as far as this is allowed in the instructions of the electrical appliances.The cables with cross-section 0.5 and 0.75 mm2 are not suitable for use in industrial electrical equipment, in agricultureand in open spaces.

C O N D U C T O R S

F O R

E L E C T R I C

A P P L I A N C E S

Uo/U - 300/300 V VDE 0281-5 and BDS HD 21.5.S3

Cu conductors PVC insulation PVC sheath

HO3VV-F, , , , , , , , , , , , , , , , , ,

HO3VVH2-F

, ,, , , ,, ,

Color coding

H03V V-F ; H03V VH2-F

Conductor resistanceat 20Ó—

VDE IEC

Core temperature max ∞C p

Rated voltage forf -ps

sssf sss

U/U / V

U/U / V

Test voltage AC, 50 Hz: V V

Temperature range:

f:

-Ó— +Ó—

-Ó— +Ó—Testing VDE

Flame test: s ss B ,VDE p IEC -

E L K A B E L

Number of core With yellow/green Without yellow/green

- ,

/ , , , ,

/ , , , , , ,

/ , , , , , , , ,

Page 270: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 270/430

269

C O N

D U C T O R S

F O R

E L E C T R I C

A P P

L I A N C E S

Uo/U - 300/500 V VDE 0281-5 and BDS HD 21.5. S3

Cu conductors PVC insulation PVC sheath

Cable construction

Conductor copper wires according toVDE 0295 Class 5and IEC 60228 Class 5

Insulation: PVC, compound Type TI2 ,according to VDE 0207 part 4

Sheath PVC, compound type TM2according to VDE 0207 part 5

Color: black or white as standard color

Different colors available upon request.

Technical data

Color coding

H05VV-F; H05VVH2-F

Construction data H05VV-F/H05VVH2-F 300/500VNumber of wires

and nominal

cross section

Approx.outer diame-

ter

Copper weight

Approx.cable weight

mm2 mm kg/Ím kg/km

HO5VV-F, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

, , , , , ,

Construction data H05VV-F/H05VVH2-F 300/500VNumber of wires

and nominal

cross section

Approx.outer diame-

ter

Copper weight

Approx.cable weight

mm2 mm kg/Ím kg/km

, , , , , , , , , , , , , , , , , ,

HO5VVH2-F, ,, ,

Conductor resistanceat 20Ó—

VDE IEC

Core temperature max ∞C p

Rated voltage for Uo/Ufor three-phase andalternating current:

for direct current systems:

U/U / V

330/550 V495/825 V

Test voltage AC, 50 Hz:H05VV-F V

Temperature range

f s-∞C +∞C-∞C +∞C

Testing VDE

Flame test: s ss B ,VDE p IEC -

Applications

H05VV-F PVC-insulated sheathed cable according to VDE 0281 part 5,HD 21.5 S3 and IEC 227-5. The cables are suitable forconnection of medium duty appliances in houses, kitchens and offices, for house appliances in wet premises i.e. refrigerators,washing machines, centrifuges as far as this is allowed in the instructions of the electrical appliances. It is allowed they to be usedfor connection of electrical heating appliances providing the conductors are not in contact with the heated parts and they shall notbe subject of other thermal effects. The cables can be installed in furniture, finished building elements and in decorative edgings.The cables are not suitable for use in open spaces, in agriculture and industry, for connection of industrial electrical appliances,

but they are allowed for use in tailoring workshops.

E L K A B E L

Number of core With yellow/green Without yellow/green - , / , , , , / , , , , , , / , , , , , , , ,

Page 271: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 271/430

270

Cable construction

Construction According to VDE 0282 part 4

Conductor Cu wires ,flexible, class 5, acc. toVDE 0295 (IEC 60228)

Insulation Silane crosslinked rubber compoundon base EPR rubber

Core identification according to VDE 0293

Sheath Silane ceosslinked rubber compoundType EM-3 on base EPR rubber

Color black

Technical data

Applications

These cables are used for connecting electrical equipment such as kitchen appliance, cookers, soldering irons andvacuum cleaners, for low medium mechanical loads.

C O N D U C T O R S

F O R

E L E C T R I C

A P P L I A N C E S

H05RR-FUo/U - 300/500 V

BDS HD 22.4 S4 and VDE 0282-4Cu conductors EPR insulation EPR sheath

Color coding

Max. operating temperature ofthe conductor +∞—

Rated voltage Uo/U V

Test voltage AC, 50 Hz - -V- -V

Ambient temperature duringexploitation - Ó— +Ó—

Bending radius, min. approx. ı

Testing acc. to VDE

Flame test D

Resistance to oil Ts ss B VDE p

Resistance to ozone Ts ss A VDE p

Number of core Without yellow/green With yellow/green

, -

, , /, ,

, ,, /, ,,

, ,, ,, /, , ,,

E L K A B E L

Page 272: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 272/430

271

C O N

D U C T O R S

F O R

E L E C T R I C

A P P

L I A N C E S

Construction data H05RR-F 300/500 V

Number of wires andnominal cross section Approx. outer diameter Copper weight Cable weight

approx.

mm2 min (mm) max (mm) kg/Ím kg/km

H05RR-F, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

, , , , , , , , , , , , , , ,

E L K A B E L

Page 273: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 273/430

Construction data H05VV5-F Uo/U - 300/500 V

Number of wires andnominal cross section

Outer diameterapprox. Copper weight Cable weight

approx.

mm2

mm2

kg/Ím kg/km

Cable construction

Conductor bare copper flexible Class5according to IEC 228

Insulation: PVC, compound Type TI2 ,according to VDE 0207 part 4

Core Identification: -2 conductors: black numbered.-3 or more conductors: black

numbered + green/yellow

Sheath PVC compound type TM5according to VDE 0207 part 5

- oil resistant

Color: gray , RAL 7001

Different colors available upon request.

272

O I L R E S I S

T A N T P V C

S H E

A T E D

C O N D U C T O R S

H05VV5 -F

ı G G G G G G

G G G G G G G G G

G G G

Uo/U - 300/500 V VDE 0281-5 and BDS HD 21.13. S1

E L K A B E L

Conductor resistance at 20∞— HD , IEC

Core temperature max ∞C p150 ∞C in the event of a short circuit

Insulation resistance, min MΩ

Rated voltage for U/U / V

Test voltage AC, 50 Hz : V

Temperature range:f:

- C + C- C + C

Testing VDE

Flame test:s ss B ,VDE p

IEC -

Application

Unscreened HAR and UL/CSA approved numbered control cable for use as connection cable for control devices ofmachine tools, assembly lines, conveyor belts and installations, in power stations, plant construction and for production

lines. It can be used with medium mechanical stress for fixed laying and flexible application, with unrestricted move-ment, without tensile stress or forced movement control, in dry, damp and wet rooms. The identification of cores bysuccessive numbers avoids mistakes when installing .

Technical data

Page 274: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 274/430

Construction data H05VV5-F Uo/U - 300/500 V

Number of wires andnominal cross section

Outer diameterapprox. Copper weight Cable weight

approx.

mm

2

mm kg/Ím kg/km

273

O I L R E S I S T A N T P V C

S H E A T E D C O N D U C T O R S

61G0.5 24.1 269 9712ı0.75 6.4 14 593G0.75 6.7 22 774G0.75 7.3 29 965G0.75 8.2 36 1206G0.75 8.9 43 1407G0.75 9.1 50 1618G0.75 10.1 58 183

10G0.75 11.9 72 23812G0.75 12.2 87 27214G0.75 13.0 101 31016G0.75 13.9 115 35618G0.75 14.6 130 39320G0.75 15.5 144 44021G0.75 15.8 151 45825G0.75 17.2 180 542

34G0.75 19.9 245 73141G0.75 21.9 296 88642G0.75 22.1 303 90450G0.75 24.0 360 106661G0.75 26.5 440 1299

2ı1 6.7 19 663G1 7.1 29 874G1 7.7 38 1105G1 8.7 48 1376G1 9.6 58 1667G1 9.6 67 1858G1 10.8 77 216

10G1 12.5 96 27212G1 12.9 115 31314G1 14.0 135 36516G1 15.0 154 41818G1 15.5 173 45320G1 16.6 192 516

21G1 16.9 202 53825G1 18.4 241 63634G1 21.3 327 85741ı1 23.4 394 103650ı1 25.7 481 124761ı1 28.3 587 1517

2ı1.5 8.2 25 903G1.5 8.7 37 1054G1.5 9.6 49 1295G1.5 10.7 62 1556G1.5 11.8 74 1827G1.5 12.0 86 1948G1.5 13.2 99 224

10G1.5 14.8 123 29312G1.5 15.3 148 33214G1.5 16.5 173 38216G1.5 17.6 197 43218G1.5 18.5 222 478

20G1.5 19.5 247 52621G1.5 19.9 259 55425G1.5 22.6 308 66748G2.5 29.7 592 1214

2ı2.5 9.3 41 1263G2.5 9.8 62 1504G2.5 11.0 82 1855G2.5 12.2 103 2226G2.5 13.5 123 2617G2.5 13.7 144 2818G2.5 15.1 165 324

10G2.5 17.2 206 42912ı2.5 18.0 247 49114ı2.5 19.3 288 56616ı2.5 20.6 329 64018ı2.5 21.7 370 70920ı2.5 22.9 411 78121ı2.5 23.5 432 82625ı2.5 25.9 514 97348ı2.5 34.3 1001 1807

Cu conductors PVC insulation PVC sheath, oil resistant

E L K A B E L

Page 275: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 275/430

274

Application

These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress orforced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and con-

necting cables to machines, tool machineries, conveyor belts and production lines. These cables have been testedaccording to DIN VDE 0207 and 0473 and found to be totally oil resistant These cables are not effected to the chemicalinfluences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washingstations.Note: These cables may be allowed to move once installed provided that the cables are not mechanically stressed dur-ing movement. The interconnection of parts of machines used for manufacturing purposes including machine toolswhere some degree of protection against electromagnetic interference is required.

O I L R E S I S

T A N T P V C S H E A T E D C O N D U C T O R S

H05VVC4V5-K Uo/U - 300/500 VVDE 0281-13, BDS HD 21.13. S1

E L K A B E L

Cable construction

Conductor bare copper flexible Class5according to IEC 228

Insulation: PVC, compound Type TI2 ,according to VDE 0281 part 1

Core Identification: -2 conductors: black numbered.-3 or more conductors: blacknumbered + green/yellow

Type of lay-up cores laid up in layers of optimum pitch

Inner sheath TM2 to DIN VDE 0281 parti1

Screen Tinned copper braided screening,covering approx. 85%

Sheath PVC, compound type TM5according to VDE 0207 part 5,

oil resistant.

Color: gray , RAL 7001

Different colors available upon request.

Technical data

Conductor resistance at 20∞— according to HD 383, IEC 228

Core temperature max 70∞C in operation.150∞C in the event of a short circuit

Insulation resistance, min 20 MΩ.kmRated voltage for Uo/U 300/500 V

Test voltage AC, 50 Hz:core/core

core/screen2000V, 5min2000V, 5min

Temperature range

mobile: -5∞C to +70∞C

fixed: -40∞C to +70∞C

Radiation resistance up to 80 Mrad

Testing VDE 0281-13:

Flame test: test class B ,VDE 0472part 804and IEC 60 332-1

Construction data H05VVC4V5-K Uo/U - 300/500 V

Number of wires andnominal cross section

Outer diameterapprox. Copper weight Cable weight

approx.

mm2 mm kg/Ím kg/km

2x0,5 8,0 30 923G0.5 8,4 36 1094G0.5 9,1 42 1265G0.5 10,1 48 1566G0.5 10,7 58 1767G0.5 11,4 64 1928G0.5 12,5 72 2119G0.5 12,5 80 230

12G0.5 13,5 105 280

Page 276: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 276/430

275

O I L R E S I S T A N T P V C

S H E A T E D C O N D U C T O R S

Construction data H05VVC4V5-K Uo/U - 300/500 V

Number of wires andnominal cross section

Outer diameterapprox. Copper weight Cable weight

approx.

mm

2

mm kg/Ím kg/km14G0.5 14,2 114 30218G0.5 15,8 137 38425G0.5 18,6 210 55627G0.5 18,6 236 59934G0.5 20,8 298 63436G0.5 20,8 317 62041 G 0,5 23,0 349 77050G0.5 25,0 470 97061 G 0,5 26,8 530 107265G0.5 28,4 563 1198

2x0,75 8,3 41 1023G0.75 8,8 48 1154G0.75 9,8 55 1505G0.75 10,8 66 173

6G0.75 11,4 75 1957G0.75 12,1 85 2358G0.75 12,7 98 2689G0.75 13,8 112 285

12G0.75 14,3 135 32714G0.75 14,4 151 36218G0.75 16,9 190 488

2x1,5 9,1 69 1463G1.5 10,2 75 1764G1.5 10,9 90 2075G1.5 11,6 108 2356G1.5 12,4 130 2797G1.5 13,5 157 3148G1.5 15,6 173 3459G1.5 15,6 185 380

12G1.5 16,8 240 50014G1.5 18,3 283 56018G1.5 20,0 355 70719G1.5 20,4 366 72325G1.5 24,2 448 95027G1.5 24,6 516 101432G1.5 26,0 702 113334G1.5 26,3 754 120436G1.5 27,7 778 126137G1.5 27,7 790 130041G1.5 29,1 805 1453

2x2,5 11,4 81 1903G2.5 11,7 104 2434G2.5 12,8 134 2805G2.5 13,9 175 342

7G2.5 15,9 225 4398G2.5 18,7 289 48912G2.5 20,6 375 76014G2.5 22,5 415 89018G2.5 24,3 522 105225G2.5 29,0 897 137527G2.5 29,8 971 1507

Cu conductors PVC insulation PVC sheath Cu screen PVC sheath, oil resistant

E L K A B E L

Page 277: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 277/430

276

O I L R E S I S

T A N T P V C S H E A T E D C O N D U C T O R S

Uo/U - 300/500 V VDE 0281-13PVC-JZ -CY

E L K A B E L

Application

These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress orforced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connect-

ing cables to machines, tool machineries, conveyor belts and production lines. These cables have been tested accordingto DIN VDE 0207 and 0473 and found to be totally oil resistant These cables are not effected to the chemical influences.Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.Note: These cables may be allowed to move once installed provided that the cables are not mechanically stressed duringmovement. The interconnection of parts of machines used for manufacturing purposes including machine tools wheresome degree of protection against electromagnetic interference is required.

Construction data OPVC-JZ-CY Uo/U - 300/500 V

Number of wires andnominal cross section

Outer diameterapprox. Copper weight Cable weight

approx.

mm2 mm kg/Ím kg/km

Cable construction

Conductor bare copper flexible Class5according to IEC 228

Insulation: PVC, compound Type TI2 ,according to VDE 0281 part 1

Core Identification: -2 conductors: black numbered.-3 or more conductors: blacknumbered + green/yellow

Type of lay-up cores laid up in layers of optimum pitch

Inner sheath TM2 to DIN VDE 0281 parti1

Screen Tinned copper braided screening,covering approx. 85%

Sheath PVC, compound type TM5according to VDE 0207 part 5,

oil resistantColor: grey , RAL 7001 or transparent

Different colors available upon request.

Technical data

2x0,5 8,0 30 923G0.5 8,4 36 1094G0.5 9,1 42 1265G0.5 10,1 48 1566G0.5 10,7 58 1767G0.5 11,4 64 1928G0.5 12,5 72 2119G0.5 12,5 80 230

12G0.5 13,5 105 28014G0.5 14,2 114 302

Conductor resistance at 20∞— according to HD 383, IEC 228

Core temperature max 70∞C in operation.150∞C in the event of a short circuit

Insulation resistance, min 20 MΩ.km

Rated voltage for Uo/U 300/500 VTest voltage AC, 50 Hz:

core/corecore/screen

2000V, 5min2000V, 5min

Temperature range

mobile: -5∞C to +70∞C

fixed: -40∞C to +70∞C

Radiation resistance up to 80 Mrad

Testing according to VDE 0472

Flame test: test class B ,VDE 0472part 804and IEC 60 332-1

Page 278: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 278/430

277

O I L R E S I S T A N T P V C

S H E A T E D C O N D U C T O R S

Construction data OPVC-JZ-CY Uo/U - 300/500 V

Number of wires andnominal cross section

Outer diameterapprox. Copper weight Cable weight

approx.

mm

2

mm kg/Ím kg/km18G0.5 15,8 137 38425G0.5 18,6 210 55627G0.5 18,6 236 59934G0.5 20,8 298 63436G0.5 20,8 317 62041 G 0,5 23,0 349 77050G0.5 25,0 470 97061 G 0,5 26,8 530 107265G0.5 28,4 563 1198

2x0,75 8,3 41 1023G0.75 8,8 48 1154G0.75 9,8 55 1505G0.75 10,8 66 1736G0.75 11,4 75 195

7G0.75 12,1 85 2358G0.75 12,7 98 2689G0.75 13,8 112 285

12G0.75 14,3 135 32714G0.75 14,4 151 36218G0.75 16,9 190 488

2x1,5 9,1 69 1463G1.5 10,2 75 1764G1.5 10,9 90 2075G1.5 11,6 108 2356G1.5 12,4 130 2797G1.5 13,5 157 3148G1.5 15,6 173 3459G1.5 15,6 185 380

12G1.5 16,8 240 500

14G1.5 18,3 283 56018G1.5 20,0 355 70719G1.5 20,4 366 72325G1.5 24,2 448 95027G1.5 24,6 516 101432G1.5 26,0 702 113334G1.5 26,3 754 120436G1.5 27,7 778 126137G1.5 27,7 790 130041G1.5 29,1 805 1453

2x2,5 11,4 81 1903G2.5 11,7 104 2434G2.5 12,8 134 2805G2.5 13,9 175 3427G2.5 15,9 225 439

8G2.5 18,7 289 48912G2.5 20,6 375 76014G2.5 22,5 415 89018G2.5 24,3 522 105225G2.5 29,0 897 137527G2.5 29,8 971 1507

Cu conductors PVC insulation PVC sheath Cu screen PVC sheath, oil resistant

E L K A B E L

Page 279: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 279/430

Construction data OPVC - JZ Uo/U - 300/500 V

Number of wires andnominal cross section

Outer diameterapprox. Copper weight Cable weight

approx.

mm2

mm kg/Ím kg/km

Cable construction

Conductor bare copper flexible Class 5according to IEC 228

Insulation: PVC, compound Type TI2 ,according to VDE 0207 part 4

Core Identification: -2 conductors: black numbered.-3 or more conductors: black

numbered + green/yellow

Sheath PVC, compound type TM5according to VDE 0207 part 5,

oil resistant

Color: grey , RAL 7001

Different colors available upon request.

Technical data

278

Application

Unscreened HAR and UL/CSA approved numbered control cable for use as connection cable for control devices ofmachine tools, assembly lines, conveyor belts and installations, in power stations, plant construction and for production

lines.It can be used with medium mechanical stress for fixed laying and flexible application, with unrestricted movement,without tensile stress or forced movement control, in dry, damp and wet rooms.The identification of cores by successive numbers avoids mistakes when installing .

O I L R E S I S

T A N T P V C S H E A T E D C O N D U C T O R S

OPVC - JZUo/U - 300/500 V

VDE 0281-13

2ı0.5 5.7 9 453G0.5 6.1 13 584G0.5 6.8 18 765G0.5 7.4 22 906G0.5 8.3 27 1107G0.5 8.3 31 1218G0.5 9.3 35 143

10G0.5 10.8 44 18012G0.5 11.2 53 20614G0.5 12.1 62 24116G0.5 12.7 71 26918G0.5 13.4 80 29720G0.5 14.2 88 33221G0.5 14.4 93 34625G0.5 15.7 110 41030G0.5 17.1 133 488

34G0.5 18.2 150 55440G0.5 19.7 177 64750G0.5 22.0 221 808

E L K A B E L

Conductor resistance at 20∞— according to HD 383, IEC 228

Core temperature max 70∞C in operation.150∞C in the event of a short circuit

Insulation resistance, min 20 MΩ.km

Rated voltage for Uo/U 300/500 V

Test voltage AC, 50 Hz:Thickness of Insulation up 0.6mm

Thickness of Insulation over 0.6mm

1500V

2000VTemperature range

mobile: -5∞C to +70∞Cfixed: -40∞C to +70∞C

Radiation resistance up to 80 Mrad

Testing according to VDE 0472

Flame test: test class B ,VDE 0472part 804and IEC 60 332-1

Page 280: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 280/430

279

O I L R E S I S T A N T P V C

S H E A T E D C O N D U C T O R S

Cu conductors PVC insulation PVC sheath, oil resistant

Construction data OPVC - JZ Uo/U - 300/500 V

Number of wires andnominal cross section

Outer diameterapprox. Copper weight Cable weight

approx.

mm

2

mm kg/Ím kg/km61G0.5 24.1 269 9712ı0.75 6.4 14 593G0.75 6.7 22 774G0.75 7.3 29 965G0.75 8.2 36 1206G0.75 8.9 43 1407G0.75 9.1 50 1618G0.75 10.1 58 183

10G0.75 11.9 72 23812G0.75 12.2 87 27214G0.75 13.0 101 31016G0.75 13.9 115 35618G0.75 14.6 130 39320G0.75 15.5 144 44021G0.75 15.8 151 45825G0.75 17.2 180 542

34G0.75 19.9 245 73141G0.75 21.9 296 88642G0.75 22.1 303 90450G0.75 24.0 360 106661G0.75 26.5 440 12992ı1 6.7 19 663G1 7.1 29 874G1 7.7 38 1105G1 8.7 48 1376G1 9.6 58 1667G1 9.6 67 1858G1 10.8 77 216

10G1 12.5 96 27212G1 12.9 115 31314G1 14.0 135 36516G1 15.0 154 41818G1 15.5 173 45320G1 16.6 192 516

21G1 16.9 202 53825G1 18.4 241 63634G1 21.3 327 85741ı1 23.4 394 103650ı1 25.7 481 124761ı1 28.3 587 15172ı1.5 8.2 25 903G1.5 8.7 37 1054G1.5 9.6 49 1295G1.5 10.7 62 1556G1.5 11.8 74 1827G1.5 12.0 86 1948G1.5 13.2 99 224

10G1.5 14.8 123 29312G1.5 15.3 148 33214G1.5 16.5 173 38216G1.5 17.6 197 432

18G1.5 18.5 222 47820G1.5 19.5 247 52621G1.5 19.9 259 55425G1.5 22.6 308 66748G2.5 29.7 592 12142ı2.5 9.3 41 1263G2.5 9.8 62 1504G2.5 11.0 82 1855G2.5 12.2 103 2226G2.5 13.5 123 2617G2.5 13.7 144 2818G2.5 15.1 165 324

10G2.5 17.2 206 42912ı2.5 18.0 247 49114ı2.5 19.3 288 56616ı2.5 20.6 329 64018ı2.5 21.7 370 70920ı2.5 22.9 411 781

21ı2.5 23.5 432 82625ı2.5 25.9 514 97348ı2.5 34.3 1001 1807

E L K A B E L

Page 281: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 281/430

280

C O

N D U C T O R S F O

R E L E C T R I C I N

S T A L L A T I O N S W

I T H L O W

E M I S

S I O N

O F S M O K E A

N D C O R R O S I V E G A S E S W H E N

A F F E C T E D B Y

F A R E

Uo/U - 300/500 VBS 7211

Cu conductors insulation LSOH

Cable construction

Conductor copper wires,according toBS 6360 ;class 1,2 or 5

Insulation: Type EI 5 , low smoke, zero halogen,termosetting insulation

Color black, red, blue, pink, gray, yellow,green, brown, white, violet, orange

Two-color combinations are not

permitted except for green/yellow.

Technical data

Application

Suitable for use in conduit and for fixed, protected installation. In particular for installation where fire, smoke emission and toxic fumes cre-ate a potential threat.

Construction data H07Z-U/R/K 450/750V

Number of wiresand nominal

cross section

Outerdiameterapprox.

Copper weight

Cable weightapprox.

mm2 mm kg/Ím kg/km

HO7Z-U1.5 2.8 14 202.5 3.0 22 294.0 3.8 36 456.0 4.3 54 64

10 5.5 90 107HO7Z-R

1.5 3.0 13 212.5 3.6 22 334.0 4.1 35 486.0 4.7 52 68

10 5.7 87 11216 6.7 139 16525 8.3 221 25935 9.4 306 34950 10.9 416 47470 12.5 601 666

985 14.6 835 922120 16.0 1056 1148

150 17.8 1302 1418185 19.9 1629 1773

Construction data H07Z-U/R/K 450/750V

Number of wiresand nominal

cross section

Outerdiameterapprox.

Copper weight

Cable weightapprox.

mm2 mm kg/Ím kg/km

240 22.7 2145 2323300 25.3 2694 2909400 28.5 3448 3709500 32.1 4428 4742600 38.1 5782 6135HO7Z-K

1.5 3.0 13 202.5 3.6 22 314.0 4.1 35 456.0 5.0 52 67

10 6.6 95 11816 7.6 147 17325 9.5 224 26535 11.4 331 37750 12.8 446 50970 14.9 636 70695 17.4 842 921

120 19.6 1075 1160150 21.1 1354 1451

185 22.5 1639 1739240 27.4 2148 2287

H07Z -U /R /K

E L K A B E L

Conductor resistance at 20∞— according to BS 6360

Core temperature max 90∞C in operation.

Insulation resistance according to BS 7211

Rated voltage Uo/U 450/750 V

Test voltage AC, 50 Hz: 2500 VTemperature range

mobile:fixed:

-5∞C to +70∞C-40∞C to +70∞C

Bending radius up to

10mm diameter 10 x cable diameter

>10 mm diameter 15 x cable diameterFlame propagation: test according to BS 4066-1

Smoke emission test according BS 7622-2

Page 282: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 282/430

B A R E

S T R A N D E

D C O N D U C

T O R S B

A R E S T R A N D E

D C O N D U C T O R S

E L K A B E L

Page 283: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 283/430

282

Application

Multi- wire copper and aluminium conductors for cables and conductors.

M U L T I

W I R E C O N D U C T O R S

Construction data Cu/Al conductors class 2

Nominal cross-section Stranding and wire diameter Electrical resistance at 20Ó—, max

mm2 N ı mm Copper conductors (Ω/km) Aluminium conductors (Ω/km)

0,50 7x0,31 36,0 -0,75 7x0,37 24,5 -1,00 7x0,44 18,1 -1,50 7x0,53 12,1 -2,50 7x0,67 7,41 -

4,0 7x0,85 4,61 7,416,0 7x1,03 3,08 4,61

10,0 7x1,35 1,83 3,0816,0 7x1,70 1,15 1,91

25 7x2,14 0,727 1,2035 7x2,50 0,524 0,86850 19x1,78 0,387 0,64170 19x2,14 0,268 0,44395 19x2,50 0,193 0,320

120 37x2,03 0,153 0,253150 37x2,25 0,124 0,206

185 37x2,50 0,0991 0,164240 61x2,25 0,0754 0,125300 61x2,50 0,0601 0,100400 61x2,85 0,0470 0,0778500 61x3,20 0,0366 0,0605

Multiwire copper andaluminium conductors class 2

IEC 60228;DIN VDE 0295;

BS 6360

E L K A B E L

Page 284: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 284/430

Application

Flexible copper wires for cables and conductors.

Construction data Cu conductors class 4

Nominal cross-section Stranding and wire diame-ter Electrical resistance at 20Ó—, max

mm2 N ı mm Copper conductors (Ω/km) Tinned copper conductors (Ω/km)

0,12 7x0,15 158,35 162,930,14 8x0,15 138,52 142,520,20 7x0,20 89,30 91,650,25 8x0,20 77,95 80,190,35 7x0,25 57,01 58,650,50 7x0,30 39,60 40,700,75 11x0,30 25,20 25,901,00 14x0,30 19,80 20,401,50 12x0,40 12,70 13,002,50 20x0,40 7,64 7,794,00 20x0,50 4,89 4,996,00 30x0,50 3,26 3,3210,0 7x7x0,50 2,00 2,0416,0 7x8x0,60 1,21 1,2425,0 7x12x0,60 0,809 0,82435,0 7x14x0,67 0,550 0,561

50,0 12x12x0,67 0,375 0,38270,0 12x16x0,67 0,281 0,28695,0 19x14x0,67 0,203 0,207120 19x18x0,67 0,158 0,161150 19x14x0,85 0,126 0,128185 30x11x0,85 0,103 0,104240 37x11x0,85 0,0798 0,0814300 37x14x0,85 0,0647 0,0660400 61x11x0,85 0,0499 0,0509500 61x14x0,85 0,0392 0,0400

283

M U L

T I WI R E C O N D U

C T O R S

BDS 904-84 Multiwire copper conductorsclass 4

E L K A B E L

Page 285: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 285/430

284

Application

Flexible copper wires for cables and conductors.

M U L T I

W I R E C O N D U C T O R S

Construction data Cu conductors class 5

Nominal cross-section Stranding and wirediameter Electrical resistance at 20Ó—, max

mm2 N ı mm Copper conductors (Ω/km) Tinned copper conductors (Ω/km)

0,50 16x0,20 39,0 40,10,75 24x0,20 26,0 26,71,00 32x0,20 19,5 20,01,50 30x0,25 13,3 13,72,50 50x0,25 7,98 8,214,00 56x0,30 4,95 5,09

6,0 84x0,30 3,30 3,3910,0 7x12x0,38 (80x0,40) 1,91 1,9516,0 7x18x0,40 1,21 1,2425,0 7x28x0,40 0,780 0,79535,0 12x23x0,40 0,554 0,56550,0 19x21x0,40 0,386 0,39370,0 19x19x0,50 0,272 0,27795,0 19x25x0,50 0,206 0,210120 19x32x0,50 0,161 0,164150 36x21x0,50 0,129 0,132

185 37x25x0,50 0,106 0,108240 37x33x0,50 0,0801 0,0817300 61x25x0,50 0,0641 0,0654400 61x33x0,50 0,0484 0,0495500 61x29x0,60 0,0384 0,0391

Multiwire copper conductorsclass 5

IEC 60228;DIN VDE 0295;

BS 6360

E L K A B E L

Page 286: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 286/430

Application

Flexible copper wires for cables and conductors.

Construction data Cu conductors class 6

Nominal cross-section Stranding and wire diame-ter Electrical resistance at 20Ó—, max

mm2 N ı mm Copper conductors (Ω/km) Tinned copper conductors (Ω/km)

0,50 28x0,15 39,0 40,10,75 42x0,15 26,0 26,71,00 56x0,15 19,5 20,01,50 7x12x0,15 (84x0,15) 13,3 13,72,50 7x20x0,15 7,98 8,214,00 7x32x0,15 4,95 5,096,00 7x26x0,20 3,30 3,3910,0 7x44x0,20 1,91 1,9516,0 19x26x0,20 1,21 1,2425,0 19x40x0,20 0,780 0,79535,0 27x40x0,20 0,554 0,56550,0 19x36x0,30 0,386 0,39370,0 27x36x0,30 0,272 0,27795,0 37x34x0,30 0,206 0,210120 37x44x0,30 0,161 0,164150 37x56x0,30 0,129 0,132

285

M U L

T I WI R E C O N D U

C T O R S

IEC 60228;DIN VDE 0295;BS 6360

Multiwire copper conductorsclass 6

E L K A B E L

Page 287: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 287/430

286

Application

For overhead electric power transmission systems.

B A

R E C O P P E R C O

N D U C T O R S F O

R O V E R H E A D L

I N E S

Construction data Cu conductors

Nominal cross-section Stranding and wirediameter

Breaking loadmin

Net weight of copperaprox.

Electrical resistanceat 20ÓC, max

mm2 N ı mm kN kg/km (Ω/km)

10 7x1,35 4,02 90 1,80616 7x1,70 6,35 143 1,13925 7x2,10 9,72 218 0,74635 7x2,50 13,77 310 0,52750 19x1,80 19,38 437 0,37670 19x2,10 26,38 596 0,27695 19x2,50 37,39 845 0,195

120 19x2,80 46,90 1060 0,155150 37x2,25 58,98 1337 0,124185 37x2,50 72,81 1649 0,100240 61x2,25 97,23 2209 0,075300 61x/2,50 120,04 2725 0,061400 61x2,89 160,42 3640 0,042500 61x3,23 200,38 4545 0,036

Bare copper conductors DIN 48201 part 1

E L K A B E L

Page 288: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 288/430

Application

For overhead electric power transmission systems.

287

BS 7884

Construction data conductors

Nominal cross-section Stranding and wirediameter

Breaking loadmin

Net weight of copperaprox.

Electrical resistanceat 20ÓC, max

mm2 N ı mm kN kg/km (Ω/km)

10 7x1,35 3,752 89,82 1,78814 7x1,60 5,267 126,2 1,27316 3x/2,65 6,194 148,3 1,08216 7x1,70 5,946 142,4 1,12825 7x2,10 9,073 217,3 0,739132 3x/3,75 12,40 296,9 0,540532 7x2,46 12,442 298,2 0,538635 7x2,50 12,860 308,0 0,521550 7x3,00 18,520 443,5 0,362250 19x1,80 17,700 435,8 0,372770 7x3,55 25,930 621,1 0,258670 19x2,10 24,090 593,2 0,273895 19x2,50 34,140 840,7 0,1932

100 7x4,30 36,540 911,2 0,1763120 19x2,80 42,830 1055 0,1540125 19x2,90 45,940 1131 0,1436

150 19x3,20 55,940 1377 0,118150 37x2,25 53,880 1334 0,1233185 19x3,55 68,860 1695 0,09582185 37x2,50 66,490 1647 0,09981

Bare copper conductors

B A R

E C O P P E R C O N

D U C T O R S F O R

O V E R H E A D L I N E S

E L K A B E L

Page 289: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 289/430

288

Application

For overhead power transmission.

B A R E A L U M I N I U M C O N D U C T

O R S A N D A L U M I N I U M

C O N D U C T O R S ,

S T E E L

- R E I N F O R C E D F

O R O V E R H E A D L I N E S

BDS 1133 - 89Bare aluminium conductors andaluminum conductors, steel reinforced

Construction data

Nominalcross-section

Stranding and wire diameter

Conductordiameter

Breakingload,min

Electricalresistance at

20oC, max Weight Al Weight St

Weight ofconductor,

approx.

mm2 N ı mm mm kN Ω/km kg/km kg/km kg/km

Type "AC"Al St

16 6x1,80+1x1,80 5,40 5,83 1,882 42 20 6225 6x2,20+1x2,20 6,60 8,652 1,260 62 30 92

35 6x2,80+1x2,80 8,40 13,38 0,778 101 48 14950 6x3,20+1x3,20 9,60 17,02 0,595 132 53 6370 6x3,80+1x3,80 11,40 23,59 0,422 187 88 27595 6x4,50+1x4,50 13,50 32,98 0,301 263 124 387

120 28x2,29+7x2,00 15,16 46,58 0,251 319 172 511150 28x2,59+7x2,20 16,96 57,19 0,196 407 209 616185 28x2,87+7x2,50 18,98 70,47 0,160 500 269 769240 28x3,29+7x2,80 21,55 89,038 0,121 657 338 995300 28x3,66+7x3,20 24,24 110,77 0,098 814 441 1255400 28x4,24+19x2,20 27,95 149,20 0,073 1092 568 1660

Type "ACO"Al St

150 24x2,8+7x1,80 16,60 46.17 0,195 408 139 547185 24x3,1+7x2,00 18,40 56.24 0,159 500 172 672240 24x3,59+7x2,40 21,56 77.04 0,119 670 248 918

300 54x2,62+7x2,60 23,52 93.48 0,099 805 291 1096400 54x3,04+7x3,00 27,24 120.48 0,074 1083 388 1471500 54x3,37+19x2,00 30,22 150.02 0,060 1332 469 1801

Construction data

Nominal cross-section

Stranding and wirediameter

Conductordiameter

Breaking load,min

Electrical resist-ance at 20oC, max

Weight of conduc-tor, approx.

mm2

N ı mm mm kN Ω/km kg/km

E L K A B E L

Type "A"16 7x1,70 5,10 2,838 1,804 4425 7x2,12 6,36 4,249 1,160 6835 7x2,50 7,50 5,778 0,834 9450 7x3,00 9,00 7,944 0,579 13670 7x3,55 10,65 10,663 0,414 19095 7x4,12 12,36 14,185 0,307 256

120 19x2,80 14,00 18,783 0,246 322150 19x3,15 15,75 23,351 0,195 407185 19x3,50 17,50 28,480 0,158 503240 19x4,00 20,00 36,292 0,121 657300 37x3,20 22,40 46,927 0,097 820400 37x3,69 25,83 60,895 0,073 1091500 37x4,15 29,05 76,073 0,058 1380

600 61x3,55 31,95 88,031 0,048 1668

Page 290: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 290/430

289

B A R E A L U MI N I U M C O

N D U C T O R S A N D

A L U MI N I U M C O

N D U C T O R S ,

S T E E

L -R E I N F O R C E D

F O R O V E R H E A D

L I N E S

VDE 48201 Part 5 Bare aluminium strandedconductors

Application

For overhead electric power transmission systems.

E L K A B E L

Construction data

Nominal cross-section

Stranding and wirediameter

Conductordiameter

Breaking load,min

Electrical resist-ance at 20oC, max

Weight of conduc-tor, approx.

mm2 N ı mm mm kN Ω/km kg/km

Al conductors16 7x1,70 5,1 2,84 1,802 4325 7x2,10 6,3 4,17 1,181 6635 7x2,50 7,50 5,78 0,833 9450 7x3,00 9,0 7,94 0,579 13550 19x1,80 9,0 8,45 0,635 13370 19x2,10 10,5 11,32 0,437 181

95 19x2,50 12,5 15,68 0,309 256120 19x2,80 14,0 18,78 0,246 322150 37x2,25 15,8 25,30 0,196 406185 37x2,50 17,5 30,54 0,1587 500240 61x2,25 20,3 39,51 0,1194 670300 61x/2,50 22,5 47,70 0,0965 827400 61x/2,89 26,0 60,86 0,0722 1104500 61x3,23 29,1 74,67 0,0578 1379

Page 291: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 291/430

Construction data

Nominalcross-section

Stranding and wire diameter

Conductordiameter

Breakingload,min

Electricalresistance at

20oC, max Weight Al Weight St

Weight ofconductor,

approx.

mm2 N ı mm mm kN Ω/km kg/km kg/km kg/km

290

Application

For overhead electric power transmission systems.

B A R E A L U M

I N I U M C O N D U C T

O R S A N D A L U M

I N I U M C

O N D U C T O R S ,

S T E E L

- R E I N F O R C E D F

O R O V E R H E A D L I N E S

Bare aluminium conductors,steel reinforced

DIN 48 204

E L K A B E L

Al/St reinforced conductorsAl St

16/2,5 6x1,80+1x1,80 5,4 5,81 1,8793 42 20 6225/4 6x2,25+1x2,25 6,8 9,02 1,2028 66 31 9735/6 6x2,70+1x2,70 8,1 12,70 0,8353 95 45 14044/32 14x2,00+7x2,40 11,2 45,46 0,6573 122 249 37350/8 6x3,20+1x3,20 9,6 17,18 0,5946 133 63 19650/30 12x2,33+7x2,33 11,7 44,28 0,5644 142 234 37870/12 26x1,85+7x1,44 11,7 26,31 0,4130 193 90 28495/15 26x2,15+7x1,67 13,6 35,17 0,3058 261 121 38395/55 12x3,20+7x3,20 16,0 80,20 0,2992 267 442 714

105/75 14x3,10+19x2,25 17,5 106,69 0,2736 293 594 899120/20 26x2,44+7x1,90 15,5 44,94 0,2374 336 156 494120/70 12x3,60+7x3,60 18,0 98,16 0,2364 338 559 904125/30 30x2,33+7x2,33 16,3 57,86 0,2259 354 234 590150/25 26x2,70+7x2,10 17,1 54,37 0,1939 412 190 604170/40 30x2,70+7x2,70 18,9 77,01 0,1682 475 315 794185/30 26x3,00+7x2,33 19,0 66,28 0,1571 508 234 744210/35 26x3,20+7x2,49 20,3 74,94 0,1380 578 267 848

210/50 30x3,00+7x3,00 21,0 92,25 0,1363 586 388 979230/30 24x3,50+7x2,33 21,0 73,09 0,1249 638 234 874240/40 26x3,45+7x2,68 21,8 86,46 0,1188 672 310 985265/35 24x3,74+7x2,49 22,4 82,94 0,1094 723 268 998300/50 26x3,86+7x3,00 24,5 105,09 0,0949 841 388 1233305/40 54x2,68+7x2,68 24,1 99,30 0,0949 843 310 1155340/30 48x3,00+7x2,33 25,0 92,56 0,0851 938 234 1174380/50 54x3,00+7x3,00 27,0 120,91 0,0757 1056 388 1448385/35 48x3,20+7x2,49 26,7 104,31 0,0748 1067 268 1336435/55 54x3,20+7x3,20 28,8 136,27 0,0666 1201 442 1647450/40 48x3,45+7x2,68 28,7 120,19 0,0644 1240 310 1553490/65 54x3,40+7x3,40 30,6 152,85 0,0590 1356 498 1860495/35 45x3,74+7x2,49 29,9 120,31 0,0584 1366 268 1636510/45 48x3,68+7x2,87 30,7 134,33 0,0566 1411 355 1770550/70 54x3,60+7x3,60 32,4 167,42 0,0526 1520 559 2085560/50 48x3,86+7x3,00 32,2 146,28 0,0514 1552 388 1943570/40 45x4,02+7x2,68 32,2 137,98 0,0506 1578 310 1889

Page 292: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 292/430

291

B A R E A L U MI N I U M C O

N D U C T O R S A N D

A L U MI N I U M C O

N D U C T O R S ,

S T E E

L -R E I N F O R C E D

F O R O V E R H E A D

L I N E S

IEC 1089 Bare aluminiumconductors

E L K A B E L

Application

For overhead power transmission.

Construction data

Nominal cross-section

Stranding and wirediameter

Conductordiameter

Breaking load,min

Electrical resist-ance at 20oC, max

Weight of conduc-tor, approx.

mm2 N ı mm mm kN Ω/km kg/km

Al conductors10 7x1,35 4,05 1,95 2,8633 27,416 7x1,71 5,12 3,04 1,7896 43,825 7x2,13 6,40 4,50 1,1453 68,440 7x2,70 8,09 6,80 0,7158 109,463 7x3,39 10,20 10,39 0,4545 172,3

100 19x2,59 12,90 17,00 0,2877 274,8

125 19x2,89 14,50 21,25 0,2302 343,6160 19x3,27 16,40 26,40 0,1798 439,8200 19x3,66 18,30 32,00 0,1439 549,7250 19x4,09 20,50 40,00 0,1151 687,1315 37x3,29 23,0 51,97 0,0916 867,9400 37x3,71 26,0 64,00 0,0721 1102450 37x3,94 27,5 72,00 0,0641 1239,8500 37x4,15 29,0 80,00 0,0577 1377,6560 37x4,39 30,7 89,60 0,0515 1542,9630 61x3,63 32,6 100,80 0,0458 1738,3

Page 293: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 293/430

Application

For overhead electric power transmission systems.

292

B A R E A L U M

I N I U M C O N D U C T

O R S A N D A L U M

I N I U M C

O N D U C T O R S ,

S T E E L

- R E I N F O R C E D F

O R O V E R H E A D L I N E S

Bare a luminium and a luminium steelreinforced stranded conductors

Construction data

Nominal cross-section

Stranding and wirediameter

Conductordiameter

Breaking load,min

Electrical resist-ance at 20oC, max

Weight of conduc-tor, approx.

mm2 N ı mm mm kN Ω/km kg/km

Type AL1 conductors16-AL1 7x1.70 5.10 3.02 1.7986 43.424- AL1 7x2.10 6.30 4.36 1.1787 66.334- AL1 7x2.50 7.50 6.01 0.8317 93.949- AL1 7x3.00 9.00 8.41 0.5776 135.248- AL1 19x1.80 9.0 8.94 0.5944 132.966- AL1 19x2.10 10.5 11.85 0.4367 180.9

93- AL1 19x2.50 12.5 16.32 0.3081 256.3117- AL1 19x2.80 14.0 19.89 0.2456 321.5147- AL1 37x2.25 15.8 26.48 0.1960 405.7182- AL1 37x2.50 17.5 31.78 0.1588 500.9243- AL1 61x2.25 20.3 43.66 0.1193 671.1299- AL1 61x2.50 22.5 52.40 0.0966 828.5400- AL1 61x2.89 26.0 68.02 0.0723 1107.1500- AL1 61x3.23 29.1 82.47 0.0579 1382.9

E L K A B E L

Construction data

Nominal

cross-section

Stranding and

wire diameter

Conductor

diameter

Breakingload,min

Electricalresistance at

20oC, max Weight Al Weight St

Weight ofconductor,

approx.

mm2 N ı mm mm kN Ω/km kg/km kg/km kg/km

Type AL1/St1A conductorsAl St

15-AL1/3-St1A 6x1,80+1x1,80 5,40 5.80 1,8769 41.85 19.85 61.724-AL1/4-St1A 6x2,25+1x2,25 6,75 8.95 1,2012 65.39 31.01 96.434-AL1/6-St1A 6x2,70+1x2,70 8,1 12.37 0,8342 94.16 44.66 138.8244-AL1/32-St1A 14x2,00+7x2,40 11,2 44.24 0,6574 121.3 248.1 369.448-AL1/8-St1A 6x3,20+1x3,20 9,60 16.81 0,5939 132.26 62.73 194.9951-AL1/30-St1A 12x2,33+7x2,33 11,7 42.98 0,5644 141.14 233.87 375.170-AL1/11-St1A 26x1,85+7x1,44 11,7 26.27 0,4132 192.76 89.32 282.194-AL1/15-St1A 26x2,15+7x1,67 13,6 34.93 0,3060 260.35 120.14 380.49

97-AL1/56-St1A 12x3,20+7x3,20 16,0 77.85 0,2992 266.22 441.12 707.34106-AL1/76-St1A 14x3,10+19x2,25 17,5 105.82 0,2742 292.2 593.8 886

Page 294: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 294/430

293

B A R E A L U MI N I U M C O

N D U C T O R S A N D

A L U MI N I U M C O

N D U C T O R S ,

S T E E

L -R E I N F O R C E D

F O R O V E R H E A D

L I N E S

BDS EN 50182

E L K A B E L

Construction data

Nominalcross-section

Stranding and wire diameter

Conductordiameter

Breakingload,min

Electricalresistance at

20

o

C, max

Weight Al Weight St Weight ofconductor,

approx.

mm2 N ı mm mm kN Ω/km kg/km kg/km kg/km

122-AL1/20-St1A 26x2,44+7x1,90 15,5 44.50 0,2376 335.32 155.51 490.83122-AL1/71-St1A 12x3,60+7x3,60 18,0 97.92 0,2364 336.94 558.3 895.24128-AL1/30-St1A 30x2,33+7x2,33 16,3 56.41 0,2260 353.09 233.87 586.96149-AL1/24-St1A 26x2,70+7x2,10 17,1 53.67 0,1940 410.6 189.97 600.57172-AL1/40-St1A 30x2,70+7x2,70 18,9 74.89 0,1683 474.13 314.03 788.16184-AL1/30-St1A 26x3,00+7x2,33 19,0 65.27 0,1571 506.91 233.87 741.0209-AL1/34-St1A 26x3,20+7x2,49 20,3 73.36 0,1381 576.75 267.09 843.84212-AL1/49-St1A 30x3,00+7x3,00 21,0 92.46 0,1363 585.35 387.7 973.05231-AL1/30-St1A 24x3,50+7x2,33 21,0 72.13 0,1250 636.44 233.87 870.31

243-AL1/39-St1A 26x3,45+7x2,68 21,8 85.12 0,1188 670.38 309.4 979.78264-AL1/34-St1A 24x3,74+7x2,49 22,4 81.04 0,1095 726.72 267.09 993.81304-AL1/49-St1A 26x3,86+7x3,00 24,4 105.09 0,0949 839.19 387.7 1226.89305-AL1/39-St1A 54x2,68+7x2,68 24,1 96.80 0,0949 841.20 309.40 1150.6339-AL1/30-St1A 48x3,00+7x2,33 25,0 91.71 0,0852 937.4 233.87 1171.2382-AL1/49-St1A 54x3,00+7x3,00 27,0 121.30 0,0758 1054.1 387.7 1440.44386-AL1/34-St1A 48x3,20+7x2,49 26,7 102.56 0,0749 1066.51 267.09 1333.6434-AL1/56-St1A 54x3,20+7x3,20 28,8 133.59 0,0666 1199.3 441.12 1641.3449-AL1/39-St1A 48x3,45+7x2,68 28,7 119.05 0,0644 1239.7 309.40 1549.1490-AL1/64-St1A 54x3,40+7x3,40 30,6 150.81 0,0590 1353.92 497.98 1851.9494-AL1/34-St1A 45x3,74+7x2,49 29,9 117.96 0,0584 1365.5 267.09 1632.6511-AL1/45-St1A 48x3,68+7x2,87 30,7 133.31 0,0566 1410.47 354.83 1765.3550-AL1/71-St1A 54x3,60+7x3,60 32,4 166.32 0,0526 1517.9 558.29 2076.2562-AL1/49-St1A 48x3,86+7x3,00 32,2 146.28 0,0515 1551.8 387.7 1939.5571-AL1/39-St1A 45x4,02+7x2,68 32,2 136.40 0,0506 1577.7 309.4 1887.1

Type AL1/St1A conductorsAl St

Page 295: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 295/430

294

B A R E A L U M

I N I U M C O N D U C T

O R S A N D A L U M

I N I U M C

O N D U C T O R S ,

S T E E L

- R E I N F O R C E D F

O R O V E R H E A D L I N E S

BS 215 part 1and BS 215 part 2

are a luminium conductors andaluminum conductors , steelreinforced

E L K A B E L

Application

For overhead power transmission.

Construction data

Nominal cross-section

Stranding and wirediameter

Conductordiameter

Breaking load,min

Electrical resist-ance at 20oC, max

Weight of conduc-tor, approx.

mm2 N ı mm mm kN Ω/km kg/km

ALUMINIUM STRANDED CONDUCTORS - BS 215 part 122 7x2,06 6,18 3,99 1,227 6450 7x3,10 9,30 8,28 0,5419 14560 7x3,40 10,20 9,90 0,4505 174

100 7x4,39 13,17 16,00 0,2702 290150 19x3,25 16,25 25,70 0,1825 434200 19x3,78 18,90 32,40 0,1349 587250 19x4,22 21,10 40,40 0,1083 731

300 19x4,65 23,25 48,75 0,08916 888400 37x3,78 26,46 63,10 0,06944 1145

Construction data

Nominal cross-section

Stranding and wirediameter

Conductor diame-ter

Breaking load,min

Electrical resist-ance at 20oC, max

Weight of conduc-tor, approx.

mm2 N ı mm mm kN Ω/km kg/km

ALUMINIUM CONDUCTORS, STEEL REINFORCED - BS 215 part 225 6x2,36+1x2,36 7,08 9,61 1,093 10630 6x2,59+1x2,59 7,77 11,45 0,9077 12840 6x3,00+1x3,00 9,00 15,20 0,6766 17250 6x3,35+1x3,35 10,05 18,35 0,5426 21470 12x2,79+7x2,79 13,95 61,20 0,3936 538

100 6x4,72+7x1,57 14,15 32,70 0,2733 394150 30x2,59+7x2,59 18,13 69,20 0,1828 726150 18x3,35+1x3,35 16,75 35,70 0,1815 506175 30x2,79+7x2,79 19,53 79,80 0,1576 842175 18x3,61+1x3,61 18,05 41,10 0,1563 587200 30x3,00+7x3,00 21,00 92,25 0,1363 974200 18x3,86+1x3,86 19,30 46,55 0,1367 671400 54x3,18+7x3,18 28,62 131,90 0,0674 1621

Page 296: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 296/430

C A B L E S A

N D W I R E S

A C C O R D I N G T O B D S

C A B L E S A

N D WI R E S

A C C O R D I N G T O B D S

E L KA B E L

Page 297: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 297/430

Cable costruction

Construction According to BDS 16291-85.Conductor solid or twisted copper wires, class 1 or

2 according to BDS 904-84 (IEC 60228).Insulation PVC compound.Sheath PVC compound.

*cable is produced without or with joint filling.

Color Grey or black.

Conductors typere circular solid conductor.rm circular stranded conductor.sm sector stranded conductor.

Technical data

Color coding

Single core - black, brown, blue,yellow/green or othercolors upon request.Double core -light blue and brown or yellow-green andblack.Other constructions according to table.

296

Application

Used for transferring and distribution of electrical power for switching installations and outdoor installation or for interiorinstallation in rooms, in canals, tunnels, shafts or pits, at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.

L O W

V O L T A

G E P O W E R C A

B L E S

E L KA B E L

SVTUo/U - 0.6/1 kV

BDS 16291-85

Conductor resistance at 20Ó— According to BDS 904-84

Max. conductor temperature +70 Ó—

Max. short circuit temperature +160 Ó—, not more than 5 sec.

Rated voltage 0,6/1 kV

Test voltage AC - 4 kV 50 Hz DC - 12 kV

Bending radius, min. 10 D cable

Temperature of laying -5 ÓC

Temperature range -30 Ó— to +50 Ó—

Flame test BDS IEC 332-1

3- core 4- core 5- core Multiple core

brown blackgrey or yel-low/greenblue brown

blue brownblack grey

oryellow/greenbrown black

grey

blue brownblack grey

blackor

yellow/greenblue brownblack grey

black with number mark oncores

orblack with number mark on

cores and yellow/greencore in the outer cover

Page 298: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 298/430

297

L O W

V O L T A G E P O W

E R C A B L E S

Cu conductors PVC insulation PVC sheath

E L KA B E L

Construction data SVT 0.6/1 kVNumber of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

Construction data SVT 0.6/1 kVNumber of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

1 ı 1.5 re 7.2 14 691 ı 2.5 re 7.6 23 82

1 ı 4.0 re 8.0 37 102

1 ı 6.0 re 8.5 55 1251 ı 10 re 9.3 93 178

1 ı 16 re 10.8 148 2531 ı 16 rm 10.8 148 253

1 ı 25 rm 11.9 229 3501 ı 35 rm 13.0 325 462

1 ı 50 rm 14.2 458 5981 ı 70 rm 16.7 648 810

1 ı 95 rm 18.4 885 11001 ı 120 rm 19.9 1120 1385

1 ı 150 rm 21.9 1378 16101 ı 185 rm 24.3 1703 2020

1 ı 240 rm 27.2 2208 25651 ı 300 rm 30.3 2765 3200

1 ı 400 rm 33.8 3680 40351 ı 500 rm 37.9 4600 5180

2 ı 1.0 re 9.3 20 100

2 ı 1.5 re 10.0 28 1202 ı 2.5 re 10.6 46 150

2 ı 4.0 re 12.1 75 2102 ı 6.0 re 13.2 110 260

2 ı 10 re 15.2 182 3702 ı 16 re 17.8 303 558

2 ı 25 rm 21.5 470 8102 ı 35 rm 23.8 652 1057

2 ı 50 rm 27.0 928 14083 ı 1.0 re 9.6 28 119

3 ı 1.5 re 10.2 42 1223 ı 2.5 re 11.0 69 154

3 ı 4.0 re 12.8 110 2603 ı 6.0 re 14.0 165 349

3 ı 10 re 16.0 275 4803 ı 16 re 18.9 450 682

3 ı 25 rm 22.8 700 1078

3 ı 35 rm 25.3 980 12983 ı 50 rm 28.9 1390 1895

3 ı 70 sm 28.8 1950 24003 ı 95 sm 33.1 2650 3225

3 ı 120 sm 35.9 3350 40103 ı 150 sm 39.3 4185 4830

3 ı 185 sm 43.4 5160 60353 ı 240 sm 48.9 6720 7818

3 ı 2.5 + 1.5 re/re 11.2 82 2033 ı 4.0 + 2.5 re/re 13.4 132 293

3 ı 6.0 + 4.0 re/re 14.4 202 3803 ı 10 + 6.0 re/re 16.7 330 545

3 ı 16 + 10 re/re 19.5 540 8703 ı 25 + 16 rm/re 24.4 850 1245

3 ı 35 + 16 rm/re 27.1 1130 15903 ı 50 + 25 rm/rm 30.8 1630 2175

3 ı 70 + 35 sm/rm 31.8 2280 2785

3 ı 95 + 50 sm/rm 36.8 3120 36803 ı 120 + 70 sm/rm 40.1 4010 4730

3 ı 150 + 70 sm/rm 44.3 4850 56203 ı 185 + 95 sm/rm 49.3 6070 7090

3 ı 240 + 120 sm/rm 55.4 7840 91504 ı 1.0 re 10.4 37 140

4 ı 1.5 re 11.0 55 165

4 ı 2.5 re 11.9 92 2164 ı 4.0 re 13.6 146 317

4 ı 6.0 re 14.4 218 408

4 ı 10 re 16.8 363 5934 ı 16 re 19.2 582 951

4 ı 25 rm 25.2 925 12854 ı 35 rm 28.0 1303 1778

4 ı 50 rm 32.0 1857 23074 ı 70 sm 33.0 2601 3101

4 ı 95 sm 37.3 3540 42504 ı 120 sm 41.2 4460 5210

4 ı 150 sm 45.2 5575 63854 ı 185 sm 49.5 6880 7960

4 ı 240 sm 56.4 8928 103105 ı 1.0 re 11.2 45 160

5 ı 1.5 re 11.8 69 1955 ı 2.5 re 12.8 114 260

5 ı 4.0 re 15.5 182 3805 ı 6.0 re 16.8 275 500

5 ı 10 re 19.2 455 735

5 ı 16 re 23.2 745 11505 ı 25 rm 27.9 1165 1700

5 ı 35 rm 32.4 1640 23605 ı 50 rm 36.9 2330 3130

5 ı 70 sm 42.0 3260 42305 ı 95 sm 48.7 4430 5640

7 ı 1.5 re 12.0 96 2308 ı 1.5 re 13.1 110 265

10 ı 1.5 re 14.7 140 31512 ı 1.5 re 15.4 165 365

14 ı 1.5 re 16.1 195 41516 ı 1.5 re 17.1 220 470

19 ı 1.5 re 18.0 260 55024 ı 1.5 re 21.2 330 690

30 ı 1.5 re 22.6 410 84037 ı 1.5 re 24.4 506 1090

7 ı 2.5 re 13.0 160 315

8 ı 2.5 re 14.1 182 36510 ı 2.5 re 16.5 228 445

12 ı 2.5 re 17.1 275 52514 ı 2.5 re 18.1 320 590

16 ı 2.5 re 19.8 365 67019 ı 2.5 re 20.3 435 780

24 ı 2.5 re 24.1 546 99530 ı 2.5 re 25.3 685 1210

37 ı 2.5 re 27.4 845 14857 ı 4.0 re 15.8 255 470

10 ı 4.0 re 20.4 365 6687 ı 6.0 re 17.3 384 630

7 ı 10 re 20.0 640 965

Page 299: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 299/430

Cable costruction

Construction According to BDS 16291-85.Conductor solid or twisted copper wires, class 1 or 2

according to BDS 904-84. (IEC 60228).Insulation PVC compound.Sheath PVC compound UV steadily.

*cable is produced without or with joint filling.Color black.

Conductors typere circular solid conductor.rm circular stranded conductor.sm sector stranded conductor.

Technical data

Color coding

Single core - black, brown, blue,yellow/green or othercolors upon request.Double core - black and blue.Other constructions according to table.

298

Application

Used for transferring and distribution of electrical power for switching installations and outdoor installation , with condi-tions of work to atmosphere influence and sunlight radiation at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.

L O W

V O L T A

G E P O W E R C A

B L E S

E L KA B E L

SVT-sUo/U - 0.6/1 kV

BDS 16291-85

Conductor resistance at 20Ó— According to BDS 904-84

Max. conductor temperature +70 Ó—

Max. short circuit temperature +160 Ó—, not more than 5 sec.

Rated voltage 0,6/1 kVTest voltage AC - 4 kV 50 Hz DC - 12 kV

Bending radius, min. 10 D cable

Temperature of laying -5 Ó—

Temperature range -30 Ó— to +50 Ó—

Flame test BDS IEC 332-1

3- core 4- core 5- core Multiple core

brown blackgrey or yel-

low/greenblue brown

blue brownblack grey

or

yellow/greenbrown blackgrey

blue brownblack grey

blackor

yellow/greenblue brownblack grey

black with number mark oncores

or

black with number mark oncores and yellow/greencore in the outer cover

Page 300: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 300/430

299

L O W

V O L T A G E P O W

E R C A B L E S

Cu conductors PVC insulation PVC sheath - UV steadily

E L KA B E L

Construction data SVT-s 0.6/1 kVNumber of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

Construction data SVT-s 0.6/1 kVNumber of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

1 ı 1.5 re 7.2 14 691 ı 2.5 re 7.6 23 821 ı 4.0 re 8.0 37 1021 ı 6.0 re 8.5 55 1251 ı 10 re 9.3 93 1781 ı 16 re 10.8 148 2531 ı 16 rm 10.8 148 2531 ı 25 rm 11.9 229 3501 ı 35 rm 13.0 325 4621 ı 50 rm 14.2 458 5981 ı 70 rm 16.7 648 8101 ı 95 rm 18.4 885 11001 ı 120 rm 19.9 1120 1385

1 ı 150 rm 21.9 1378 16101 ı 185 rm 24.3 1703 20201 ı 240 rm 27.2 2208 25651 ı 300 rm 30.3 2765 32001 ı 400 rm 33.8 3680 40351 ı 500 rm 37.9 4600 51802 ı 1.0 re 9.3 20 1002 ı 1.5 re 10.0 28 1202 ı 2.5 re 10.6 46 1502 ı 4.0 re 12.1 75 2102 ı 6.0 re 13.2 110 2602 ı 10 re 15.2 182 3702 ı 16 re 17.8 303 5582 ı 25 rm 21.5 470 8102 ı 35 rm 23.8 652 1057

2 ı 50 rm 27.0 928 14083 ı 1.0 re 9.6 28 1193 ı 1.5 re 10.2 42 1223 ı 2.5 re 11.0 69 1543 ı 4.0 re 12.8 110 2603 ı 6.0 re 14.0 165 3493 ı 10 re 16.0 275 4803 ı 16 re 18.9 450 6823 ı 25 rm 22.8 700 10783 ı 35 rm 25.3 980 12983 ı 50 rm 28.9 1390 18953 ı 70 sm 28.8 1950 24003 ı 95 sm 33.1 2650 32253 ı 120 sm 35.9 3350 40103 ı 150 sm 39.3 4185 48303 ı 185 sm 43.4 5160 60353 ı 240 sm 48.9 6720 7818

3 ı 2.5 + 1.5 re/re 11.2 82 2033 ı 4.0 + 2.5 re/re 13.4 132 2933 ı 6.0 + 4.0 re/re 14.4 202 3803 ı 10 + 6.0 re/re 16.7 330 5453 ı 16 + 10 re/re 19.5 540 8703 ı 25 + 16 rm/re 24.4 850 12453 ı 35 + 16 rm/re 27.1 1130 15903 ı 50 + 25 rm/rm 30.8 1630 21753 ı 70 + 35 sm/rm 31.8 2280 27853 ı 95 + 50 sm/rm 36.8 3120 36803 ı 120 + 70 sm/rm 40.1 4010 47303 ı 150 + 70 sm/rm 44.3 4850 5620

3 ı 185 + 95 sm/rm 49.3 6070 70903 ı 240 + 120 sm/rm 55.4 7840 9150

4 ı 1.0 re 10.4 37 1404 ı 1.5 re 11.0 55 1654 ı 2.5 re 11.9 92 2164 ı 4.0 re 13.6 146 3174 ı 6.0 re 14.4 218 4084 ı 10 re 16.8 363 5934 ı 16 re 19.2 582 9514 ı 25 rm 25.2 925 12854 ı 35 rm 28.0 1303 17784 ı 50 rm 32.0 1857 23074 ı 70 sm 33.0 2601 3101

4 ı 95 sm 37.3 3540 42504 ı 120 sm 41.2 4460 52104 ı 150 sm 45.2 5575 63854 ı 185 sm 49.5 6880 79604 ı 240 sm 56.4 8928 103105 ı 1.0 re 11.2 45 1605 ı 1.5 re 11.8 69 1955 ı 2.5 re 12.8 114 2605 ı 4.0 re 15.5 182 3805 ı 6.0 re 16.8 275 5005 ı 10 re 19.2 455 7355 ı 16 re 23.2 745 11505 ı 25 rm 27.9 1165 17005 ı 35 rm 32.4 1640 23605 ı 50 rm 36.9 2330 3130

5 ı 70 sm 42.0 3260 42305 ı 95 sm 48.7 4430 56407 ı 1.5 re 12.0 96 2308 ı 1.5 re 13.1 110 26510 ı 1.5 re 14.7 140 31512 ı 1.5 re 15.4 165 36514 ı 1.5 re 16.1 195 41516 ı 1.5 re 17.1 220 47019 ı 1.5 re 18.0 260 55024 ı 1.5 re 21.2 330 69030 ı 1.5 re 22.6 410 84037 ı 1.5 re 24.4 506 10907 ı 2.5 re 13.0 160 3158 ı 2.5 re 14.1 182 36510 ı 2.5 re 16.5 228 44512 ı 2.5 re 17.1 275 52514 ı 2.5 re 18.1 320 59016 ı 2.5 re 19.8 365 67019 ı 2.5 re 20.3 435 78024 ı 2.5 re 24.1 546 99530 ı 2.5 re 25.3 685 121037 ı 2.5 re 27.4 845 14857 ı 4.0 re 15.8 255 47010 ı 4.0 re 20.4 365 6687 ı 6.0 re 17.3 384 6307 ı 10 re 20.0 640 965

Note: Cable may be produced without joint filling.

Page 301: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 301/430

Cable costruction

Construction According to BDS 16291-85.Conductor solid or twisted aluminum wires class 1

or 2, according to BDS 904-84 (IEC 60228).Insulation PVC compound.Sheath PVC compound.

*cable may be with or without joint filling.Color gray.

Conductors typere circular, solid conductor.rm circular, stranded conductor.sm sector, stranded conductor.

Technical data

Color coding

Single core - black, brown, blue,yellow/green or othercolors upon request.Double core - blue and brown or yellow-green and

black.Other construction according to table.

300

Application

Used for transferring and distribution of electrical power for switching installations and outdoor installation or for interiorinstallation in rooms, in canals, tunnels, shafts or pits, at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.

L O W

V O L T A

G E P O W E R C A

B L E S

E L KA B E L

SAVTUo/U - 0.6/1 kV

BDS 16291-85

Conductor resistance at 20Ó— According to BDS 904-84

Max. conductor temperature +70 Ó—

Max. short circuit temperature +160 Ó—, not more than 5 sec.

Rated voltage 0,6/1 kV

Test voltage AC - 4 kV 50 Hz DC - 12 kV

Bending radius, min. 10 D cable

Temperature of laying -5 Ó—

Temperature range -30 Ó— to +50 Ó—

Flame test BDS IEC332-1

3- core 4- core 5- core Multiple core

brown black

grey or yel-low/greenblue brown

blue brownblack grey

oryellow/greenbrown black

grey

blue brownblack grey

blackoryellow/green

blue brownblack grey

black with number mark oncores

orblack with number mark oncores and yellow/greencore in the outer cover

Page 302: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 302/430

301

L O W

V O L T A G E P O W

E R C A B L E S

Al conductors PVC insulation PVC sheath

E L KA B E L

Construction data SAVT 0.6/1 kVNumber of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Al weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

Construction data SAVT 0.6/1 kVNumber of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Al weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

1 ı 4.0 re 8.1 12 781 ı 6.0 re 8.6 17 911 ı 10 re 9.4 28 1151 ı 16 re 10.2 45 1501 ı 25 re 11.4 68 1871 ı 35 rm 13.0 95 2251 ı 50 rm 14.2 127 2651 ı 70 rm 16.7 190 3601 ı 95 rm 18.4 260 4651 ı 120 rm 19.9 325 5501 ı 150 rm 21.9 405 6801 ı 185 rm 24.3 510 8301 ı 240 rm 27.2 665 1065

1 ı 300 rm 30.3 830 13051 ı 400 rm 33.8 1060 15951 ı 500 rm 37.9 1410 20702 ı 2.5 re 10.3 14 1202 ı 4.0 re 12.2 23 1602 ı 6.0 re 13.3 34 1852 ı 10 re 14.8 56 2452 ı 16 re 16.8 90 3402 ı 25 re 20.3 137 4703 ı 2.5 re 11.0 21 1303 ı 4.0 re 12.8 36 1853 ı 6.0 re 14.0 51 2253 ı 10 re 15.8 85 2903 ı 16 re 18.2 135 3803 ı 25 re 21.6 210 610

3 ı 35 rm 25.3 290 7403 ı 50 rm 28.8 385 9503 ı 70 sm 28.8 585 10903 ı 95 sm 33.1 810 14903 ı 120 sm 35.9 1020 17103 ı 150 sm 39.3 1255 20603 ı 185 sm 43.8 1560 26103 ı 240 sm 49.4 2035 3320

3 ı 4.0 + 2.5 re/re 13.4 42 2053 ı 6.0 +4.0 re/re 14.4 63 2403 ı 10 + 6.0 re/re 16.7 101 3203 ı 16 + 10 re/re 19.2 165 4753 ı 25 + 16 re/re 23.0 255 6303 ı 35 + 16 rm/re 26.8 340 8253 ı 50 + 25 rm/rm 30.8 480 10253 ı 70 + 35 sm/rm 31.8 670 12503 ı 95 + 50 sm/rm 37.0 910 16803 ı 120 + 70 sm/rm 40.1 1180 20103 ı 150 + 70 sm/rm 44.3 1405 24153 ı 185 + 95 sm/rm 49.3 1780 29753 ı240 + 120 sm/rm 55.4 2310 3805

4 ı 2.5 re 11.9 28 1524 ı 4.0 re 14.1 46 2164 ı 6.0 re 15.4 68 2604 ı 10 re 17.4 112 3404 ı 16 re 19.8 180 4604 ı 25 re 23.8 270 6704 ı 35 rm 28.0 390 9054 ı 50 rm 32.0 520 11804 ı 70 sm 33.0 760 13904 ı 95 sm 38.1 1060 18604 ı 120 sm 41.4 1340 22104 ı 150 sm 46.0 1650 27104 ı 185 sm 51.1 2100 33204 ı 240 sm 58.0 2720 41105 ı 2.5 re 12.8 35 180

5 ı 4.0 re 15.5 58 2705 ı 6.0 re 16.8 85 3205 ı 10 re 19.2 140 4305 ı 16 re 23.2 225 5805 ı 25 re 27.9 345 8555 ı 35 rm 32.4 480 12105 ı 50 rm 36.9 650 14705 ı 70 sm 42.0 965 1955

Note: Cable may be produced without joint filling

Page 303: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 303/430

Cable costruction

Construction According to BDS 16291-85.Conductor solid or twisted copper wires, class 1

or 2, BDS 904-84 (IEC 60228).Insulation PVC compound.Inner sheath PVC compound.

Outer sheath PVC compound.Color Gray or black.

Conductors typere circular, solid conductor.rm circular, stranded conductor.sm sector, stranded conductor.

Technical data

Color coding

Single core - black, brown, blue,yellow/green or othercolors upon request.Double core - blue and brown or yellow-green and

black.Other constructions according to table.

302

Application

Used for transferring and distribution of electrical power for switching installations and outdoor installation or for interiorinstallation in rooms, in canals, tunnels, shafts or pits, at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.

L O W

V O L T A

G E P O W E R C A

B L E S

E L KA B E L

SVTTUo/U - 0.6/1 kV

BDS 16291-85

Conductor resistance at 20 Ó— According to BDS 904-84

Max. conductor temperature +70 Ó—

Max. short circuit temperature +160 Ó—, not more than 5 sec.

Rated voltage 0,6/1 kV

Test voltage AC - 4 kV 50 Hz DC - 12 kV

Bending radius, min. 10 D cable

Temperature of laying -5 Ó—

Temperature range -30 Ó— to +50 Ó—

Flame test BDS IEC332-1

3- core 4- core 5- core Multiple core

brown blackgrey or

yellow/greenblue brown

blue brownblack grey or

yellow/greenbrown blackgrey

blue brownblack grey

black

oryellow/greenblue brownblack grey

black with number mark oncores

or

black with number mark oncores and yellow/green corein the outer cover

Page 304: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 304/430

303

L O W

V O L T A G E P O W

E R C A B L E S

Cu conductors PVC insulation PVC sheath

E L KA B E L

Note: During the extrusion it is permitted simultaneous laying of the inner and outer sheath.

Construction data SVTT 0.6/1 kVNumber of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

Construction data SVTT 0.6/1 kVNumber of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Cu weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

1 ı 1.5 re 9.5 14 1081 ı 2.5 re 9.9 23 1241 ı 4.0 re 10.3 37 1431 ı 6.0 re 10.8 55 1701 ı 10 re 11.6 93 2211 ı 16 re 13.2 148 3081 ı 16 rm 13.2 148 3081 ı 25 rm 14.3 229 4121 ı 35 rm 15.4 325 5241 ı 50 rm 16.6 458 6591 ı 70 rm 18.4 648 8801 ı 95 rm 20.4 885 11611 ı 120 rm 22.0 1120 1430

1 ı 150 rm 23.9 1378 17521 ı 185 rm 26.2 1703 21561 ı 240 rm 29.3 2208 27351 ı 300 rm 32.0 2765 34121 ı 400 rm 35.6 3680 43241 ı 500 rm 39.9 4600 54322 ı 1.0 re 10.3 20 1322 ı 1.5 re 10.8 28 1582 ı 2.5 re 11.5 46 1822 ı 4.0 re 13.4 75 2502 ı 6.0 re 14.2 110 3052 ı 10 re 16.1 182 4182 ı 16 re 19.1 303 5872 ı 25 rm 22.2 470 8752 ı 35 rm 24.2 652 1235

2 ı 50 rm 27.6 928 15103 ı 1.0 re 10.7 28 1453 ı 1.5 re 11.2 42 1703 ı 2.5 re 12.0 69 2143 ı 4.0 re 14.0 110 2953 ı 6.0 re 15.0 165 3743 ı 10 re 16.9 275 5203 ı 16 re 20.2 450 7653 ı 25 rm 23.2 700 11253 ı 35 rm 25.6 980 14653 ı 50 rm 29.1 1390 19603 ı 70 sm 30.0 1950 24503 ı 95 sm 34.5 2650 33103 ı 120 sm 37.3 3350 40653 ı 150 sm 40.9 4185 49503 ı 185 sm 45.4 5160 61603 ı 240 sm 51.0 6720 7950

3 ı 2.5 + 1.5 re/re 12.5 82 2303 ı 4.0 + 2.5 re/re 14.6 132 3303 ı 6.0 + 4.0 re/re 15.7 202 3903 ı 10 + 6.0 re/re 17.5 330 5903 ı 16 + 10 re/re 19.6 540 8953 ı 25 + 16 rm/re 24.9 850 13033 ı 35 + 16 rm/re 27.1 1130 16613 ı 50 + 25 rm/rm 30.8 1630 22283 ı 70 + 35 sm/rm 33.2 2280 28593 ı 95 + 50 sm/rm 38.2 3120 38753 ı 120 + 70 sm/rm 41.5 4010 4829

3 ı 150 + 70 sm/rm 44.9 4850 57503 ı 185 + 95 sm/rm 50.9 6070 72503 ı 240 + 120 sm/rm 55.7 7840 9330

4 ı 1.0 re 11.4 37 1644 ı 1.5 re 12.0 55 1984 ı 2.5 re 12.9 92 2504 ı 4.0 re 15.1 146 3514 ı 6.0 re 16.2 218 4504 ı 10 re 18.2 363 6454 ı 16 re 22.0 582 9804 ı 25 rm 25.5 925 14504 ı 35 rm 28.3 1303 18604 ı 50 rm 32.6 1857 2476

4 ı 70 sm 34.4 2601 32054 ı 95 sm 39.6 3540 43604 ı 120 sm 43.0 4460 53404 ı 150 sm 47.6 5575 65454 ı 185 sm 53.0 6880 81754 ı 240 sm 60.0 8928 106255 ı 1.0 re 12.2 45 1985 ı 1.5 re 12.8 69 2355 ı 2.5 re 13.8 114 3005 ı 4.0 re 16.4 182 4305 ı 6.0 re 17.6 275 5605 ı 10 re 19.8 455 7985 ı 16 re 24.3 745 12305 ı 25 rm 28.9 1165 18305 ı 35 rm 33.2 1640 2420

5 ı 50 rm 37.3 2330 32805 ı 70 sm 42.9 3260 43905 ı 95 sm 49.4 4430 59407 ı 1.5 re 13.8 96 2908 ı 1.5 re 14.8 110 31810 ı 1.5 re 16.5 140 37812 ı 1.5 re 17.2 165 42014 ı 1.5 re 18.0 195 48016 ı 1.5 re 18.7 220 56019 ı 1.5 re 19.6 260 62024 ı 1.5 re 22.7 330 76030 ı 1.5 re 23.9 410 90037 ı 1.5 re 25.8 506 11907 ı 2.5 re 14.8 160 3488 ı 2.5 re 15.9 182 40510 ı 2.5 re 18.4 228 52012 ı 2.5 re 18.7 275 59014 ı 2.5 re 19.6 320 66016 ı 2.5 re 20.8 365 74019 ı 2.5 re 21.7 435 84524 ı 2.5 re 25.1 546 105030 ı 2.5 re 26.5 685 129037 ı 2.5 re 28.6 845 15207 ı 4.0 re 17.4 255 54010 ı 4.0 re 21.8 365 7807 ı 6.0 re 19.0 384 7357 ı 10 re 21.4 640 1070

Page 305: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 305/430

Cable costruction

Construction According to BDS 16291-85.Conductor solid or twisted Al wires, class 1 or 2

according to BDS 904-84 (IEC 60228).Insulation PVC compound.Inner sheath PVC compound.

Outer sheath PVC compound.Color Gray or black.

Conductors typere circular, solid conductor.rm circular, stranded conductor.sm sector, stranded conductor.

Technical data

Color coding

Single core - black, brown, blue,yellow/green or othercolors upon request.Double core - blue and brown or yellow-green and

black.Other constructions according to table.

304

Application

Used for transferring and distribution of electrical power for switching installations and outdoor installation or for interiorinstallation in rooms, in canals, tunnels, shafts or pits, at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.

L O W

V O L T A

G E P O W E R C A

B L E S

E L KA B E L

SAVTTUo/U - 0.6/1 kV

BDS 16291-85

Conductor resistance at 20Ó— According to BDS 904-84

Max. conductor temperature +70 Ó—

Max. short circuit temperature +160 Ó—, not more than 5 sec.

Rated voltage 0,6/1 kV

Test voltage AC - 4 kV 50 Hz DC - 12 kV

Bending radius, min. 10 D cable

Temperature of laying -5 Ó—

Temperature range -30 Ó— to +50 Ó—

Flame test BDS IEC332-1

3- core 4- core 5- core Multiple core

brown blackgrey

oryellow/greenblue brown

blue brownblack grey

oryellow/greenbrown black

grey

blue brownblack grey

black

oryellow/greenblue brownblack grey

black with number mark oncores

orblack with number mark oncores and yellow/greencore in the outer cover

Page 306: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 306/430

305

L O W

V O L T A G E P O W

E R C A B L E S

Al conductors PVC insulation PVC sheath

E L KA B E L

Note: During the extrusion it is permitted simultaneous laying of the inner and outer sheath.

Construction data SAVTT 0.6/1 kVNumber of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Al weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

Construction data SAVTT 0.6/1 kVNumber of wires and

nominalcross sec-

tion

Shape

Outerdiameterof cableapprox.

Al weight

Cable weightapprox.

N ı mm2 mm kg/km kg/km

1 ı 4.0 re 10.3 12 1201 ı 6.0 re 10.8 17 1341 ı 10 re 11.6 28 1601 ı 16 re 13.2 45 2101 ı 25 re 14.3 68 2471 ı 35 rm 15.4 95 2951 ı 50 rm 16.6 127 3551 ı 70 rm 18.4 190 4651 ı 95 rm 20.4 260 5751 ı 120 rm 22.0 325 6631 ı 150 rm 23.9 405 7851 ı 185 rm 26.2 510 9511 ı 240 rm 29.3 665 1193

1 ı 300 rm 32.0 830 14501 ı 400 rm 35.6 1060 18341 ı 500 rm 39.9 1410 22652 ı 2.5 re 11.5 14 1552 ı 4.0 re 13.4 23 2122 ı 6.0 re 14.3 34 2482 ı 10 re 15.9 56 3072 ı 16 re 17.7 90 3892 ı 25 re 21.4 137 5453 ı 2.5 re 12.0 21 1653 ı 4.0 re 14.0 36 2333 ı 6.0 re 15.0 51 2773 ı 10 re 16.7 85 3453 ı 16 re 18.7 135 4443 ı 25 re 22.0 210 626

3 ı 35 rm 25.5 290 8173 ı 50 rm 29.1 385 10753 ı 70 sm 30.0 585 11563 ı 95 sm 34.5 810 15573 ı 120 sm 37.3 1020 18233 ı 150 sm 40.9 1255 22853 ı 185 sm 45.4 1560 27303 ı 240 sm 51.0 2035 3405

3 ı 4.0 + 2.5 re/re 14.6 42 241

3 ı 6.0 + 4.0 re/re 15.7 63 2843 ı 10 + 6.0 re/re 17.5 101 3643 ı 16 + 10 re/re 19.6 165 4953 ı 25 + 16 re/re 24.9 255 6763 ı 35 + 16 rm/re 27.1 340 9003 ı 50 + 25 rm/rm 30.8 480 10953 ı 70 + 35 sm/rm 33.2 670 13603 ı 95 + 50 sm/rm 38.2 910 18403 ı 120 + 70 sm/rm 41.5 1180 22103 ı 150 + 70 sm/rm 44.9 1405 27353 ı 185 + 95 sm/rm 50.9 1780 32453 ı240 + 120 sm/rm 55.7 2310 4276

4 ı 2.5 re 12.9 28 152

4 ı 4.0 re 15.1 46 2164 ı 6.0 re 16.2 68 2604 ı 10 re 18.2 112 3404 ı 16 re 22.0 180 4604 ı 25 re 25.5 270 6704 ı 35 rm 28.3 390 9054 ı 50 rm 32.6 520 11804 ı 70 sm 34.4 760 13904 ı 95 sm 39.6 1060 18604 ı 120 sm 43.0 1340 22104 ı 150 sm 47.6 1650 27104 ı 185 sm 53.0 2100 33204 ı 240 sm 60.0 2720 41105 ı 2.5 re 13.8 35 1805 ı 4.0 re 16.4 58 270

5 ı 6.0 re 17.6 85 3205 ı 10 re 19.8 140 4305 ı 16 re 24.3 225 5805 ı 25 re 28.9 345 8555 ı 35 rm 33.2 480 12105 ı 50 rm 37.3 650 14705 ı 70 sm 42.9 965 19555 ı 95 sm 49.4 1345 2545

Page 307: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 307/430

Cable design

Construction According to BDS 16291-85Conductor solid or twisted copper wires,

class 1 or 2, BDS 904-84(IEC 60228)

Insulation PVC compoundInner sheath PVC compound

Armour Steel tapesOuter sheath PVC compoundColor Gray or black

Conductors typere circular, solid conductorrm circular, stranded conductorsm sector, stranded conductor

Technical data

Color coding

Single core - black, brown, blue,yellow/green or othercolors upon requestDouble core - blue and brown or yellow-green and blackOther constructions according to table

306

Application

Used for transfer and distribution of electrical power for switching installation and in static installations, at rated voltageUo/U to 0,6/1 kV with frequency 50 Hz.These cables are used for indoor installations, in the open air, in ditches, tun-nels, canals and shafts.

L O W

V O L T A

G E P O W E R C A

B L E S

SVBTUo/U - 0.6/1 kV

BDS 16291-85

Conductor resistance at20 ∞C According to BDS 904-84

Max. conductor tempera-ture +70 ∞C

Max. short circuit tempera-ture

+160 ∞C, not more than 5sec.

Rated voltage 0,6/1 kV

Test voltage AC - 4 kV 50 Hz DC - 12 kV

Bending radius, min. 15 D cable.

Temperature of laying -5 ∞C

Temperature range -30 ∞C to +50 ∞C

Flame test BDS IEC332-1

3 - core 4 - core 5 - core Multiple core

brownblackgreyor

yellow/greenblue

brown

bluebrownblackgreyor

yellow/greenbrown

blackgrey

bluebrownblackgreyblack

oryellow/gre

enbluebrownblackgrey

black with numbermark on cores

orblack with number

mark on cores and yel-low/green core in theouter cover

E L KA B E L

Page 308: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 308/430

307

L O W

V O L T A G E P O W

E R C A B L E S

Cu conductors PVC insulation Armour St tapes PVC sheath

Constructive data SVBT 0.6/1 kVNumber ofconductorsand nominalcross sec-

tion

Shape

Outercable

diameterapprox.

Copper weight

Cable weightapprox.

N x mm2 mm kg/km kg/km

Constructive data SVBT 0.6/1 kVNumber ofconductorsand nominalcross sec-

tion

Shape

Outercable

diameterapprox.

Copper weight

Cable weightapprox.

N x mm2 mm kg/km kg/km

1 ı 10 re 12.5 93 3021 ı 16 rm 13.5 148 3811 ı 25 rm 15.3 229 5151 ı 35 rm 16.4 325 6241 ı 50 rm 17.6 458 7711 ı 70 rm 19.9 648 10251 ı 95 rm 21.6 885 13051 ı 120 rm 23.3 1120 15751 ı 150 rm 25.1 1378 18901 ı 185 rm 27.7 1703 23071 ı 240 rm 30.6 2208 29352 ı 2.5 re 12.7 46 2612 ı 4 re 14.6 75 346

2 ı 6 re 15.7 110 4152 ı 10 re 17.3 182 5382 ı 16 re 19.3 303 7112 ı 25 rm 23.7 470 10382 ı 35 rm 25.9 652 13152 ı 50 rm 29.4 928 17063 ı 1.5 re 12.4 42 2523 ı 2.5 re 13.2 69 2973 ı 4 re 15.4 110 4103 ı 6 re 16.4 165 4903 ı 10 re 18.3 275 6603 ı 16 re 20.3 450 8803 ı 25 rm 25.0 700 13263 ı 35 rm 27.5 980 16853 ı 50 rm 31.3 1390 2210

3 ı 70 sm 32.2 1950 27543 ı 95 sm 36.7 2650 36703 ı 120 sm 39.5 3350 44523 ı 150 sm 43.1 4185 53683 ı 185 sm 47.6 5160 66353 ı 240 sm 53.4 6720 8501

3 ı 2.5 + 1.5 re+re 13.7 82 2953 ı 4 + 2.5 re+re 16.0 132 4503 ı 6 + 4 re+re 17.1 202 545

3 ı 10 + 6 re+re 19.1 330 7363 ı 16 + 10 re+re 21.2 540 9963 ı 25 + 16 rm+re 26.3 850 15143 ı 35 + 16 rm+re 29.1 1130 18903 ı 50 + 25 rm+rm 33.0 1630 24993 ı 70 + 35 sm+rm 35.4 2280 32123 ı 95 + 50 sm+rm 40.2 3120 41803 ı 120 + 70 sm+rm 43.7 4010 52603 ı 150 + 70 sm+rm 48.1 4850 62203 ı 185 + 95 sm+rm 53.3 6070 7786

3 ı 240 + 120 sm+rm 59.6 7840 99104 ı 1.5 re 13.2 55 2864 ı 2.5 re 14.1 92 3504 ı 4 re 16.5 146 4804 ı 6 re 17.6 218 5804 ı 10 re 19.8 363 8004 ı 16 re 22.0 582 10804 ı 25 rm 27.4 925 16424 ı 35 rm 30.4 1303 21754 ı 50 rm 34.4 1857 27624 ı 70 sm 36.6 2601 34784 ı 95 sm 42.0 3540 47914 ı 120 sm 45.4 4460 5800

4 ı 150 sm 50.0 5575 79754 ı 185 sm 55.2 6880 81174 ı 240 sm 62.2 8928 100805 ı 1.5 re 14.0 69 3315 ı 2.5 re 15.2 114 4135 ı 4 re 17.7 182 5675 ı 6 re 19.2 275 7085 ı 10 re 21.4 455 9705 ı 16 re 24.0 745 13245 ı 25 rm 30.7 1165 20485 ı 35 rm 33.4 1640 27585 ı 50 rm 38.7 2330 38405 ı 70 rm 43.7 3260 51287 ı 1.5 re 15.2 96 4218 ı 1.5 re 16.2 110 465

10 ı 1.5 re 18.3 140 57112 ı 1.5 re 18.8 165 61014 ı 1.5 re 19.5 195 67516 ı 1.5 re 20.5 220 74019 ı 1.5 re 21.3 260 81424 ı 1.5 re 24.5 330 104230 ı 1.5 re 25.7 410 118037 ı 1.5 re 27.7 506 13707 ı 2.5 re 16.3 160 5088 ı 2.5 re 17.3 182 57010 ı 2.5 re 19.9 228 71912 ı 2.5 re 20.4 275 77814 ı 2.5 re 21.4 320 83816 ı 2.5 re 22.6 365 94119 ı 2.5 re 23.5 435 105024 ı 2.5 re 27.0 546 135430 ı 2.5 re 28.4 685 155137 ı 2.5 re 30.8 845 1820

E L KA B E L

Page 309: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 309/430

Cable design

Construction According to BDS 16291-85

Conductor solid or twisted aluminum wires class

1 or 2, according to BDS 904-84

(IEC 60228)

Insulation PVC compound

Inner sheath PVC compound

Armour steel tapes

Sheath PVC compound

Color Gray or black

Conductors type

re circular, solid conductor

rm circular, stranded conductor

sm sector, stranded conductor

Technical data

Color coding

Single core - black, brown, blue,yellow/green or other

colors upon requestDouble core - blue and brown or yellow-green and blackOther constructions according to table

308

Application

Used for transferring and distribution of electrical power for switching installations and outdoor installation or for interiorinstallation in rooms at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.These cables are used for indoor installations, in the open air, in ditches, tunnels, canals and shafts.

L O W

V O L T A

G E P O W E R C A

B L E S

SAVBTUo/U - 0.6/1 kV

BDS 16291-85

Conductor resistance at20 ∞C According to BDS 904-84

Max. conductor tempera-ture +70 ∞C

Max. short circuit temper-ature

+160 ∞C, not more than 5sec.

Rated voltage 0,6/1 kV

Test voltage AC - 4 kV 50 Hz DC - 12 kV

Bending radius, min. 15 D cable

Temperature of laying -5 ∞C

Temperature range -30 ∞C to +50 ∞C

Flame test BDS IEC332-1

3 - core 4 - core 5 - core Multiple core

brownblackgreyor

yellow/green

bluebrown

bluebrownblackgreyor

yellow/green

brownblackgrey

bluebrownblack

greyblackor

yellow/greenblue

brownblackgrey

black with number

mark on coresorblack with number

mark on cores and yel-low/green core in the

outer cover

E L KA B E L

Page 310: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 310/430

309

L O W

V O L T A G E P O W

E R C A B L E S

Constructive data SAVBT 0.6/1 kVNumber ofconductorsand nominalcross sec-

tion

Shape

Outercable

diameterapprox.

Al weightCable

weightapprox.

N x mm2 mm kg/km kg/km

Constructive data SAVBT 0.6/1 kVNumber ofconductorsand nominalcross sec-

tion

Shape

Outercable

diameterapprox.

Al weightCable

weightapprox.

N x mm2 mm kg/km kg/km

1 ı 10 re 12.5 28 2401 ı 16 re 13.5 45 2801 ı 25 re 14.6 68 3321 ı 35 rm 16.4 95 4071 ı 50 rm 17.6 127 4761 ı 70 rm 19.9 190 5951 ı 95 rm 21.6 260 7101 ı 120 rm 23.3 325 8241 ı 150 rm 25.1 405 9631 ı 185 rm 27.7 510 11521 ı 240 rm 30.6 665 14262 ı 2.5 re 12.7 14 2322 ı 4 re 14.6 23 298

2 ı 6 re 15.7 34 3412 ı 10 re 17.3 56 4122 ı 16 re 19.3 90 5102 ı 25 re 23.7 137 6873 ı 2.5 re 13.2 21 2533 ı 4 re 15.4 36 3353 ı 6 re 16.4 51 3803 ı 10 re 18.3 85 4733 ı 16 re 20.3 135 5853 ı 25 re 25.0 210 6993 ı 35 rm 27.5 290 10143 ı 50 rm 31.3 385 12903 ı 70 sm 32.2 585 14693 ı 95 sm 36.7 810 18893 ı 120 sm 39.5 1020 2205

3 ı 150 sm 43.1 1255 26073 ı 185 sm 47.6 1560 31603 ı 240 sm 53.4 2035 3948

3 ı 4 + 2,5 re+re 16.0 42 3603 ı 6 + 4 re+re 17.1 63 413

3 ı 10 + 6 re+re 19.1 101 5143 ı 16 + 10 re+re 21.2 165 6383 ı 25 + 16 re+re 26.3 255 8743 ı 35 + 16 rm+re 29.1 340 9293 ı 50 + 25 rm+rm 33.0 480 13493 ı 70 + 35 sm+rm 35.4 670 16973 ı 95 + 50 sm+rm 40.2 910 21833 ı 120 + 70 sm+rm 43.7 1180 25623 ı 150 + 70 sm+rm 48.1 1405 30063 ı 185 + 95 sm+rm 53.3 1780 36833 ı240 + 120 sm+rm 59.6 2310 4565

4 ı 2,5 re 14.1 28 2864 ı 4 re 16.5 46 381

4 ı 6 re 17.6 68 4344 ı 10 re 19.8 112 5494 ı 16 re 22.0 180 6834 ı 25 rm 27.4 270 9354 ı 35 rm 30.4 390 12234 ı 50 sm 34.4 520 15404 ı 70 sm 36.6 760 18554 ı 95 sm 42.0 1060 24154 ı 120 sm 45.4 1340 28114 ı 150 sm 50.0 1650 33914 ı 185 sm 55.2 2100 40824 ı 240 sm 62.2 2720 51495 ı 2.5 re 15.2 35 3345 ı 4 re 17.7 58 4455 ı 6 re 19.2 85 520

5 ı 10 re 21.4 140 6525 ı 16 re 24.0 225 8295 ı 25 re 30.7 345 12455 ı 35 rm 33.4 480 16005 ı 50 rm 38.7 650 2160

Al conductors PVC insulation Armour St. tapes PVC sheath

E L KA B E L

Page 311: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 311/430

310

Application

These cables are used in signaling systems, automatics and block systems in the railway transport.

L O W

V O L T A

G E P O W E R C A

B L E S

SVOBTU to 1kV

BDS 11303-83

Cable design

Construction According to BDS 11303-83

Conductor copper, single core accordingto BDS 904-84 class1

Insulation PVC compoundaccording to BDS 5792-84

Insulation color according to BDS 11303-83

Filling PVC compound

Led sheath according to BDS 4712-84

Inner sheath thermoplastic material

Armour Steel tapes

Sheath PVC compound accordingto BDS 5792-84

Color gray

Technical data

Conductor resistance at

20 ∞Caccording to BDS 11303-83

Operating temperature max 70 ∞C

Nominal voltage to 1 ÍV

Test voltage AC, 50 Hz 4 ÍV

Temperature of exploita-

tion- 25 ∞C to + 50 ∞C

Bending radius, min, Fixed 15 x D cable

Tests BDS 11303-83

E L KA B E L

Color coding

3- core 4- core 5- core Multiple core

brownblackgreyor

yellow/greenblue

brown

bluebrownblackgreyor

yellow/greenbrownblackgrey

blue

brownblackgreyblack

oryellow/green

bluebrownblackgrey

black with number mark on coresor

black with number mark on cores and yellow/greencore in the outer cover

Page 312: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 312/430

311

L O W

V O L T A G E P O W

E R C A B L E S

Constructive data SVOBT up to 1 kV

Number of conductors and nomi-nal cross section

Outer cable diameterapprox. Copper weight Cable weight

approx.

N x mm2 mm kg/km kg/km

Cu conductors PVC insulation Pb sheath Armour St. tapes PVC sheath

3x1.5 18.0 42 8403x2.5 19.5 70 9604x1.5 17.7 55 8504x2.5 19.8 92 10504ı4.0 21.0 146 12205ı1.5 18.8 70 9606ı1.5 19.6 85 10527ı1.5 19.6 98 10687ı2.5 21.5 160 12908ı1.5 20.6 110 11408ı4.0 25.0 280 170010ı1.5 22.8 140 136010ı4.0 28.4 365 2150

12ı1.5 23.4 165 145014ı1.5 24.0 195 155014ı2.5 27.0 320 190016ı1.5 25.0 220 165019ı1.5 25.9 260 176519ı2.5 29.3 435 230024ı1.5 29.3 330 218524ı2.5 33.5 546 287030ı1.5 30.7 410 243530ı2.5 35.0 685 320037ı1.5 32.7 506 2850

E L KA B E L

Page 313: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 313/430

L O W

V O L T A

G E P O W E R C A

B L E S

E L KA B E L 312

SAPEmT-et

Application

The single-core cables with polyethylene (PE) insulation Cu screen are used mainly for electrical systems with nominalvoltage 3 ÍV and are applicable for electrical public and metropolitan transportation. They can be used for transfer,

distribution and electrical power supply with nominal voltage Uo/U 0.6/1 kV and frequency of 50Hz. The cables are forfixed assembly in lines with unlimited difference levels, underground, in cable ducts, tunnels and conduits, over shelvesand grilles outdoor under shelter.

Cable construction

Construction According to BDS 2581-86

Conductor ¿l solid round multi coresBDS 2581-86( IEC 60228 ) class 2

Insulation PE compound

Metal screen copper tapes

Sheath PVC compound type P-1

Color gray

Technical data

Uo/U - 0.6/1 kVU(=) 3 kV

BDS 2581-86 AL conductors PE insulation —u screen PVC sheath

Construction data SAPEmT-et 0.6/1 kV U(=) 3 kV

Number ofconductors andnominal cross

section

Thickness ofinsulation

Nominal crosssection of

screenmin.

Thickness ofsheath

Cable diam-eter

approx.Mass of

Alapprox.

Cable weightapprox.

N ı mm2 mm mm2 mm mm kg/km kg/km

Uo/U 0.6/1kVU(=) 3kV

1x300ÍÛ

1x400ÍÛ1x500ÍÛ

2.4

2.63.0

2.5

2.52.5

2.0

2.12.2

30.8

34.338.3

830

10601410

1358

16912158

SAPEmT-Ât

Conductor resistanceat 20∞C

According toBDS— 904 (IEC 60228) class 2

Operating temperature

Overload temperatureχı.100h/per year

90∞— continuous operation

130∞—

Short circuit temperature 250∞— /5 s max/

Nominal voltage-alternating-constant

0.6/1 kV3 ÍV

Highest system voltageUo/U no more than

0.6/1 ÍV1.2 kV

Test voltage AC - 5 min

Bending radius, min.

Temperature of laying

Between core and screen -3.5kV

15x D cable

no less than -5∞—

Temperature ofexploitation -30 to 50∞—

Force of strain in laying NMax.

¿l cores - 30*n*S coren- number of cores and

S- cross section of cores inmm

Page 314: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 314/430

313

L O W

V O L T A G E P O W

E R C A B L E S

E L KA B E L

Cable construction

Construction According to BDS 2581-86

Conductor ¿l solid round stranded

BDS 2581-86 (IEC 60228) class 2

Insulation ’LPE compound

Metal screen copper tapes

Sheath PVC compound type P-5

Color red

Technical data

Nominal voltage-alternating

-constant

0.6/1 kV

3 ÍVHighest system voltage

Uo/U no more than0.6/1 ÍV1.2 kV

Test voltage AC - 5 min

Bending radius, min.

Temperature of laying

Between core and screen -3.5kV

15x D cable

no less than -5∞—

Temperature ofexploitation -30 to 50∞—

Force of strain in laying NMax.

¿l cores - 30*n*S coren- number of cores and

S- cross section of cores inmm

Application

The single-core cables with cross-linked polyethylene (XLPE) insulation Cu screen are used mainly for electricalsystems with nominal voltage 3 ÍV and are applicable for electrical public and metropolitan transportation. They can be

used for transfer, distribution and electrical power supply with nominal voltage Uo/U 0.6/1 kV and frequency of 50Hz.The cables are for fixed assembly in lines with unlimited difference levels, underground, in cable ducts, tunnels andconduits, over shelves and grilles outdoor under shelter.

SAHEmT-etUo/U - 0.6/1 kV

U(=) 3 kVBDS 2581-86

Construction data SAHEm-et 0.6/1 kV U(=) 3 kVNumber of

conductors andnominal cross

section

Thickness ofinsulation

Nominal crosssection of

screenmin.

Thickness ofsheath

Cable diam-eter

approx.Mass of

Alapprox.

Cable weightapprox.

N ı mm2 mm mm2 mm mm kg/km kg/km

Uo/U 0.6/1kVU(=) 3kV

1ı95ÍÛ1ı120ÍÛ1ı150ÍÛ1ı185ÍÛ1x240ÍÛ

1x300ÍÛ1x400ÍÛ1x500ÍÛ

2.52.52.52.52.5

3.03.03.0

2525252525

252525

2.52.52.52.52.5

3.03.03.0

22.924.325.827.529.9

34.239.937.0

260325405510665

83010601410

735125594310841287

162819202323

SAHEm-et

Conductor resistanceat 20∞C

According toBDS— 904 (IEC 60228) class 2

Operating temperature

Overload temperatureχı.100h/per year

90∞— continuous operation

130∞—

Short circuit temperature 250∞— /5 s max/

Page 315: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 315/430

Cable construction

Construction According to BDS 2581-86

Conductor —u and Al stranded compacted,according to BDS 904 ( IEC60228 )class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Separating layer Layer of plastic tapeSheath PVC compound type P-5Color red

Technical data

Conductor resistance at20∞C

According toBDS904 (IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max/

Nominal voltage Uo/U: 3.6/6;6/10;12/20;18/30;20/35kV

Highest system voltageUo/U, no more than

3.6/6; 6/10; 12/20; 18/30;20/35kV7.2kV;12kV; 24kV; 36kV; 42kV

Test voltage Uo/U AC (≈) - 5 min

DC (=) - 15 min

3.6/6; 6/10; 12/20; 18/30;20/35kV11kV; 15kV; 30kV; 45kV; 50kV

29kV; 48kV; 96kV; 144kV; 160kVLevel of partial discharge

at 2*UoBending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than -5∞—

Temperature ofexploitation -30 to 50∞—

Force of strain in laying Nmax.where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section of conductorsin mm

314

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution of electri-cal power with nominal voltage Uo/U 3.6/6; 6/10; 12/20; 18/30; 20/35 kV and frequency 50 Hz in urban and district electricalnetworks and for electrical supply of transformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduits andshafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

SHEkTSAHEkT

Uo/U - 3.6/6; 6/10; 12/20; 18/30;20/35 kV

BDS 2581-86

Construction data SHEkT, SAHEkT 3.6/6; 6/10; 12/20; 18/30; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof

insulation

Thicknessof

sheath

Nominalcross-sec-

tion ofscreen

Cablediameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

Uo/U 3.6/6kV

1x35rm/161x50rm/161x70rm/161x95rm/16

1x120rm/161x150rm/16*1x185rm/16*1x240rm/16*

2.52.52.52.5

2.52.52.52.5

2.52.52.52.5

2.52.52.52.5

16161616

1616*16*16*

21.522.524.526

27.52930.533.0

4906007901030

1255150518402365

80594011701445

1695199523652970

95130190260

330405510665

176176176176

176176176176

580640735840

940106012001430

SHEkT SAHEkT

E L KA B E L

Page 316: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 316/430

315

MI D D L E V O L T A G E P

O WE R C A B L E S

Construction data SHEkT, SAHEkT 3.6/6; 6/10; 12/20; 18/30; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross-sec-

tion ofscreen

Cablediameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

1x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35Uo/U 6/10kV1x35rm/161x50rm/161x70rm/161x95rm/161x120rm/161x150rm/16*1x185rm/16*1x240rm/16*

1x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 12/20kV

1x35rm/161x50rm/161x70rm/161x95rm/161x120rm/161x150rm/16*1x185rm/16*1x240rm/16*

1x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 18/30kV

1x50rm/161x70rm/161x95rm/161x120rm/161x150rm/161x185rm/161x240rm/161x150rm/25

1x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 20/35kV

1x50rm/161x70rm/161x95rm/161x120rm/161x150rm/16*1x185rm/16*1x240rm/16*1x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

2.52.52.62.83.03.2

3.43.43.43.43.43.43.43.4

3.43.43.43.43.43.4

5.55.55.55.55.55.55.55.5

5.55.55.55.55.55.5

8.08.08.08.08.08.08.08.0

8.08.08.08.08.0

8.88.88.88.88.88.88.88.88.88.88.88.88.8

2.52.52.52.52.52.5

2.52.52.52.52.52.52.52.5

2.52.52.52.52.52.5

2.52.52.52.52.52.52.52.5

2.52.52.52.52.52.5

2.52.52.52.52.52.52.52.5

2.52.52.52.62.7

2.52.52.52.52.52.52.52.52.52.52.52.62.7

252525253535

161616161616*16*16*

252525253535

161616161616*16*16*

252525253535

1616161616*16*16*25

2525253535

1616161616*16*16*252525253535

29.53133.536.039.543.0

2324262729303234

30.532.534.5374043

2728303233.5353739.5

35.537.540424548

3536373940424440.5

42.544.54750.554

35.537394141.543.546424446.548.55255.5

159519302450298038354805

49060079010301255150518402365

159519302450298038354805

49060079010301255150518402365

159519302450298038354805

600790103012551505184023651595

19302450298038354805

60079010301255150518402365159519302450298038354805

208024553055367046355750

9301075131015901855215025303120

224026203210380047305740

11151260151018051995238527753370

246528603465407050256125

15051765207823581515184523551595

19302450298038354805

1515177521002400272031403775280032253870

450055006660

40551066583010601410

95130190260330405510665

40551066583010601410

95130190260330405510665

40551066583010601410

130190260330405510665405

51066583010601410

13019026033040551066540551066583010601410

265265265265363363

176176176176176176176176

265265265265363363

176176176176176176176176

265265265265363363

176176176176176176176265

265265265363363

176176176176176176176265265265265363363

114512851515177022052610

7007708759901100121013601580

130014501670189023002650

870940107011901230144016001840

153016901920215025802970

12051330147516001740190521501820

19902245252029953415

1215134015001640178519702240186520552335259530703520

SHEkT SAHEkT

Cu / Al conductors XLPE insulation Cu screen PVC sheath

E L KA B E L

Page 317: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 317/430

Cable construction

Construction According to BDS 2581-86 andadditional N 4

Conductor —u and Al stranded compacted,according to BDS 904 (IEC60228)class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compoundOuter semi-conductive layer semi-conductive XLPE compound

Water resisting Layer of semi-conductive waterelement absorbing tapesMetal screen Cu wires concentrically laid and

one contact of Cu tape withthickness of 0.1mm.

Water resisting -I option - water absorbingelement insulating tape

-II option - water absorbing powderand a layer of plastic tape

Sheath PE type MDPE

Color Black

Technical data

316

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 3.6/6; 6/10; 12/20; 18/30; 20/35 kV and frequency 50 Hz in urban and districtelectrical networks and for electrical supply of transformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduits

and shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

SHEk(vn)PSAHEk(vn)P

Uo/U-3.6/6; 6/10; 12/20; 18/30; 20/35 kV

BDS 2581-86 and additional 4

Construction data SHEk(vn)P, SAHEk(vn)P 3.6/6; 6/10; 12/20; 18/30; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof insulation

Thicknessof

sheath

Nominalcross-sec-

tion ofscreen

Cablediameterapprox. Mass of

Cuapprox.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

Uo/U 3.6/6kV

1x35rm/161x50rm/161x70rm/161x95rm/161x120rm/161x150rm/161x185rm/161x240rm/16

1x150rm/251x185rm/251x240rm/25

2.52.52.52.52.52.52.52.5

2.52.52.6

2.52.52.52.52.52.52.52.5

2.52.52.5

161616161616*16*16*

252525

22232526.52829.531.533.5

303234

49060079010301255150518402365

159519302450

795930115514301690198023602950

206024403040

95130190260330405510665

405510665

176176176176176176176176

265265265

570625720825935104011901415112012701500

SHEk(vn)P SAHEk(vn)P

Conductor resistance at20∞C

According toBDS904 (IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max/

Nominal voltage Uo/U: 3.6/6;6/10;12/20;18/30;20/35kV

Highest system voltageUo/U, no more than

3.6/6; 6/10; 12/20; 18/30;20/35kV7.2kV;12kV; 24kV; 36kV; 42kV

Test voltage Uo/U AC (≈) - 5 min

DC (=) - 15 min

3.6/6; 6/10; 12/20; 18/30;20/35kV11kV; 15kV; 30kV; 45kV; 50kV

29kV; 48kV; 96kV; 144kV; 160kV

Level of partial dischargeat 2*Uo

Bending radius, minTemperature of laying

max. 5 pC15x D cable

no less than -5∞—

Temperature ofexploitation -30 to 50∞—

Force of strain in laying Nmax.where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section of conductors inmm

E L KA B E L

Page 318: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 318/430

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PE sheath

Construction data SHEk(vn)P, SAHEk(vn)P 3.6/6; 6/10; 12/20; 18/30; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof insulation

Thicknessof

sheath

Nominalcross-sec-

tion ofscreen

Cablediameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

1x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35Uo/U 6/10kV

1x35rm/161x50rm/161x70rm/161x95rm/161x120rm/16

1x150rm/161x185rm/161x240rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 12/20kV1x35rm/161x50rm/161x70rm/161x95rm/161x120rm/161x150ÍÛ/161x185rm/161x240rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 18/30kV

1x50rm/161x70rm/161x95rm/161x120rm/161x150rm/251x185rm/25

1x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 20/35kV

1x50rm/161x70rm/161x95rm/161x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/251x240rm/25

1x300rm/251x400rm/351x500rm/35

2.52.52.62.83.03.2

3.43.43.43.43.4

3.43.43.43.43.43.43.43.43.4

5.55.55.55.55.55.55.55.55.55.55.55.55.55.5

8.08.08.08.08.08.0

8.08.08.08.0

8.88.88.88.88.88.88.88.88.88.8

8.88.88.8

2.52.52.52.52.52.5

2.52.52.52.52.5

2.52.52.52.52.52.52.52.52.5

2.52.52.52.52.52.52.52.52.52.52.52.52.52.5

2.52.52.52.52.52.5

2.52.52.52.5

2.52.52.52.52.52.52.52.52.52.5

2.52.62.8

252525253535

1616161616

16*16*16*252525253535

161616161616*16*16*252525253535

161616162525

25253535

1616161616*16*16*252525

253535

303234374145

2425272931

32343632343638.54245

28293133343637.540363840.542.54649

35.536.537.539.54143

454851.555

36.538404243444743.54547.5

5053.556.5

159519302450298038354805

49060079010301255

150518402365159519302450298038354805

49060079010301255150518402365159519302450298038354805

6007901030125515951930

2450298038354805

60079010301255150518402365159519302450

298038354805

206024403040365046105990

9051045127515601820

211524903080220025703160375046805720

10801225147017601950234027303400242028103400401049506050

146017202030230527053105

3725436053456480

1480175020652355269030803720277031753815

445038304800

40551066583010601410

95130190260330

40551066540551066583010601410

9513019026033040551066540551066583010601410

130190260330405510

66583010601410

130190260330405510665405510665

83010601410

265265265265363363

176176176176176

176176176265265265265363363

176176176176176176176176265265265265363363

176176176176265265

265265363363

176176176176176176176265265265

265363363

112012701500174521802560

6707458459501060

118013251540126014051625185022502600

855925104011651195140015601875150016401875211025352920

116012851425155017701935

2185245529153340

1185132014601600175019152175183020002270

225030103430

SHEk(vn)P SAHEk(vn)P

E L KA B E L

Page 319: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 319/430

Cable construction

Construction According to BDS 2581-86 andadditional N 4

Conductor —u and Al stranded compacted,according to BDS 904 (IEC60228)class 2

Inner semi-conductive layer semi-conductive XLPE compoundInsulation XLPE compoundOuter semi-

conductiv.layer semi-conductive XLPE compound Water resistingelement Layer of semi-conductive water

absorbing tapesMetal screen Cu wires concentrically laid and

one contact of Cu tape withthickness of 0.1mm.

Water resistingelement - water absorbing powderRadialprotection from Al foil with copolymer

moisture ingress layer

Sheath PE type MDPEColor Black

Technical data

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operationOverload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./Nominal voltage Uo/U: 6/10;12/20 kVHighest system voltage

Uo/U, no more than6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—Temperature of

exploitationForce of strain in laying

-30 to 50∞— Al cores - 30*n*S core

N max Cu cores - 50*n*S core

where:N is number of cores andS is cross section of coresin mm

Tests - water penetrationin the region of metallicscreen

IEC 60502-2 annex D

318

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 6/10; 12/20 kV and frequency 50 Hz in urban and district electrical networksand for electrical supply of transformer's substations, small and medium industrial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

SHEk(v)PSAHEk(v)P

Uo/U - 6/10; 12/20 kVBDS 2581-86 and additional 4

Construction data SHEk(v)P, SAHEk(v)P 3.6/6; 6/10; 12/20; 18/30; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross-sec-

tion ofscreen

Cablediameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx..

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

Uo/U 3.6/6kV

1x35rm/161x50rm/161x70rm/161x95rm/161x120rm/16

1x150rm/161x185rm/161x240rm/16

2.52.52.52.52.5

2.52.52.5

2.52.52.52.52.5

2.52.52.5

1616161616

16*16*16*

22232526.528

29.531.533.5

49060079010301255

150518402365

795930115514301690

198023602950

95130190260330

405510665

176176176176176

176176176

570625720825935

104011901415

SHEk(v)P SAHEk(v)P

E L KA B E L

Page 320: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 320/430

319

MI D D L E V O L T A G E P

O WE R C A B L E S

Construction data SHEk(v)P, SAHEk(v)P 3.6/6; 6/10; 12/20; 18/30; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof insulation

Thicknessof

sheath

Nominalcross-sec-

tion ofscreen

Cablediameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

1x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35Uo/U 6/10kV

1x35rm/161x50rm/161x70rm/161x95rm/161x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 12/20kV

1x35rm/161x50rm/161x70rm/161x95rm/161x120rm/161x150rm/16

1x185rm/161x240rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 18/30kV

1x50rm/161x70rm/161x95rm/161x120rm/161x150rm/251x185rm/25

1x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 20/35kV1x50rm/161x70rm/161x95rm/161x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/251x240rm/25

1x300rm/251x400rm/351x500rm/35

2.52.52.62.83.03.2

3.43.43.43.43.43.43.43.43.43.43.43.43.43.4

5.55.55.55.55.55.5

5.55.55.55.55.55.55.55.5

8.08.08.08.08.08.0

8.08.08.08.0

8.88.88.88.88.88.88.88.88.88.8

8.88.88.8

2.52.52.52.52.52.5

2.52.52.52.52.52.52.52.52.52.52.52.52.52.5

2.52.52.52.52.52.5

2.52.52.52.52.52.52.52.5

2.52.52.52.52.52.5

2.52.52.52.5

2.52.52.52.52.52.52.52.52.52.5

2.52.62.8

252525253535

161616161616*16*16*252525253535

161616161616*

16*16*252525253535

161616162525

25253535

1616161616*16*16*252525

253535

303234374145

242527293132343632343638.54245

282931333436

37.540363840.542.54649

35.536.537.539.54143

454851.555

36.538404243444743.54547.5

5053.556.5

159519302450298038354805

49060079010301255150518402365159519302450298038354805

490600790103012551505

18402365159519302450298038354805

6007901030125515951930

2450298038354805

60079010301255150518402365159519302450

298038354805

206024403040365046105990

9051045127515601820211524903080220025703160375046805720

108012251470176019502340

27303400242028103400401049506050

146017202030230527053105

3725436053456480

1480175020652355269030803720277031753815

445038304800

40551066583010601410

9513019026033040551066540551066583010601410

95130190260330405

51066540551066583010601410

130190260330405510

66583010601410

130190260330405510665405510665

83010601410

265265265265363363

176176176176176176176176265265265265363363

176176176176176176

176176265265265265363363

176176176176265265

265265363363

176176176176176176176265265265

265363363

112012701500174521802560

6707458459501060118013251540126014051625185022502600

8559251040116511951400

15601875150016401875211025352920

116012851425155017701935

2185245529153340

1185132014601600175019152175183020002270

225030103430

SHEk(v)P SAHEk(v)P

Cu / Al conductors XLPE insulation Cu screen PE sheath

E L KA B E L

Page 321: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 321/430

Cable construction

Construction According to BDS 2581-86 andadditional N 4

Conductor —u and Al stranded compacted,according to BDS 904 (IEC60228)class 2

Water resistingelement with water powder absorbingInner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compoundOuter semi-conductiv.layer semi-conductive XLPE compound

Water resistingelement Layer of semi-conductive water

absorbing tapes

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm.

Water resistingelement - water absorbing powder Radialprotection frommoisture ingress Al foil with copolymer

layer Sheath PE type MDPE

Color Black

Technical data

320

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) and longitudinal water-blocking elements aredesigned for transfer and distribution of electrical power with nominal voltage Uo/U 6/10; 12/20 kV and frequency 50 Hzin urban and district electrical networks and for electrical supply of transformer's substations, small and medium indus-trial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

SvHEk(v)PSAvHEk(v)P

Uo/U - 6/10; 12/20 kVBDS 2581-86 and additional 4

Construction data SvHEk(v)P, SAvHEk(v)P 3.6/6; 6/10; 12/20; 18/30; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross-sec-

tion ofscreen

Cablediameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

Uo/U 3.6/6kV

1x35rm/161x50rm/161x70rm/161x95rm/161x120rm/161x150rm/16

1x185rm/161x240rm/16

2.52.52.52.52.52.5

2.52.5

2.52.52.52.52.52.5

2.52.5

161616161616*

16*16*

22232526.52829.5

31.533.5

490600790103012551505

18402365

7959301155143016901980

23602950

95130190260330405

510665

176176176176176176

176176

5706257208259351040

11901415

SvHEk(v)P SAvHEk(v)P

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operationOverload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 min

DC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV

48kV; 96kV kVLevel of partial discharge

at 2*UoBending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation

Force of strain in laying

-30 to 50∞—

Al cores - 30*n*S coreN max Cu cores - 50*n*S core

where:N is number of cores andS is cross section of coresin mm

Tests - water penetrationin the region of metallic

screen

IEC 60502-2 annex D

E L KA B E L

Page 322: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 322/430

321

MI D D L E V O L T A G E P

O WE R C A B L E S

Construction data SvHEk(v)P, SAvHEk(v)P 3.6/6; 6/10; 12/20; 18/30; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross-sec-

tion ofscreen

Cablediameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Al

approx.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

1x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35Uo/U 6/10kV

1x35rm/161x50rm/161x70rm/161x95rm/161x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 12/20kV1x35rm/161x50rm/161x70rm/161x95rm/161x120rm/161x150rm/16

1x185rm/161x240rm/161x150rm/251x185rm/251x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 18/30kV

1x50rm/161x70rm/161x95rm/161x120rm/161x150rm/251x185rm/25

1x240rm/251x300rm/251x400rm/351x500rm/35

Uo/U 20/35kV

1x50rm/161x70rm/161x95rm/161x120rm/161x150rm/161x185rm/161x240rm/161x150rm/251x185rm/251x240rm/25

1x300rm/251x400rm/351x500rm/35

2.52.52.62.83.03.2

3.43.43.43.43.43.43.43.43.43.43.43.43.43.4

5.55.55.55.55.55.5

5.55.55.55.55.55.55.55.5

8.08.08.08.08.08.0

8.08.08.08.0

8.88.88.88.88.88.88.88.88.88.8

8.88.88.8

2.52.52.52.52.52.5

2.52.52.52.52.52.52.52.52.52.52.52.52.52.5

2.52.52.52.52.52.5

2.52.52.52.52.52.52.52.5

2.52.52.52.52.52.5

2.52.52.52.5

2.52.52.52.52.52.52.52.52.52.5

2.52.62.8

252525253535

161616161616*16*16*252525253535

161616161616*

16*16*252525253535

161616162525

25253535

1616161616*16*16*252525

253535

303234374145

242527293132343632343638.54245

282931333436

37.540363840.542.54649

35.536.537.539.54143

454851.555

36.538404243444743.54547.5

5053.556.5

159519302450298038354805

49060079010301255150518402365159519302450298038354805

490600790103012551505

18402365159519302450298038354805

6007901030125515951930

2450298038354805

60079010301255150518402365159519302450

298038354805

206024403040365046105990

9051045127515601820211524903080220025703160375046805720

108012251470176019502340

27303400242028103400401049506050

146017202030230527053105

3725436053456480

1480175020652355269030803720277031753815

445038304800

40551066583010601410

9513019026033040551066540551066583010601410

95130190260330405

51066540551066583010601410

130190260330405510

66583010601410

130190260330405510665405510665

83010601410

265265265265363363

176176176176176176176176265265265265363363

176176176176176176

176176265265265265363363

176176176176265265

265265363363

176176176176176176176265265265

265363363

112012701500174521802560

6707458459501060118013251540126014051625185022502600

8559251040116511951400

15601875150016401875211025352920

116012851425155017701935

2185245529153340

1185132014601600175019152175183020002270

225030103430

SvHEk(v)P SAvHEk(v)P

Cu / Al conductors XLPE insulation Cu screen PE sheath

E L KA B E L

Page 323: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 323/430

Cable construction

Construction According to BDS 2581-86 andadditional N 4

Conductor —u and Al stranded compacted,according to BDS 904 (IEC60228)class 2

Inner semi- semi-conductive XLPE compoundconductive layer

Insulation XLPE compound

Outer semi- semi-conductive XLPE compoundconductiv.layer

Water resisting Layer of semi-conductive waterelement absorbing tapes

Metal screen Al foil with copolymer layerand Radial section Al foil - 25mm2

protection from equivalency Cu - 16mm2

moisture ingress

Sheath PE type MDPE

Color Black

Technical data

322

Application

The single-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 6/10; 12/20 kV and frequency 50 Hz in urban and district electrical networksand for electrical supply of transformer's substations, small and medium industrial plants.

They are suitable for use in distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A

B L E S

SHEa(v)PSAHEa(v)P

Uo/U - 6/10; 12/20 kVBDS 2581-86 and additional 4

Conductor resistance at20∞C

According to BDS904(IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max./

Nominal voltage Uo/U: 6/10;12/20 kV

Highest system voltageUo/U, no more than

6/10; 12/20 kV12kV; 24kV kV

Test voltage Uo/U AC (≈) - 5 minDC (=) - 15 min

6/10; 12/20 kV15kV; 30kV kV48kV; 96kV kV

Level of partial dischargeat 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than - 20∞—

Temperature ofexploitation

Force of strain in laying

-30 to 50∞—

Al cores - 30*n*S core

N max Cu cores - 50*n*S core

where:N is number of cores andS is cross section of coresin mm

Tests - water penetrationin the region of metallicscreen

IEC 60502-2 annex D

E L KA B E L

Page 324: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 324/430

323

MI D D L E V O L T A G E P

O WE R C A B L E S

Cu / Al conductors XLPE insulation Cu screen PE sheath

Construction data SHEa(v)P, SAHEa(v)P 6/10 and 12/20 kV

Number of con-ductors and nom-inal cross section

Thicknessof insula-

tion

Thicknessof

sheath

Nominalcross-sec-

tion ofscreen

Cablediameterapprox.

Mass of Al

approx.

Mass ofcable

approx.

Mass ofCu

approx.

Mass of Al

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

Uo/U 6/10kV

1x185rm/25

Uo/U 12/20kV

1x95rm/251x120rrm/251x150rm/251x185rm/25

3.4

5.55.55.5

5.5

2.5

2.52.52.5

2.5

25(Cu16)

25(Cu16)25(Cu16)25(Cu16)25(Cu16)

33

3233.535

37

584

334404479

586

1150

98910641224

1384

1664

85410791329

1664

74

747474

76

2315

1584177421642554

SAHEa(v)P SHEa(v)P

E L KA B E L

Page 325: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 325/430

Cable construction

Construction According to BDS 2581-86

Conductor —u and Al stranded compacted,according to BDS 904 (IEC60228)class 2

Inner semi-conductive layer semi-conductive XLPE compound

Insulation XLPE compound

Outer semi-conductive layer semi-conductive XLPE compound

Metal screen Cu wires concentrically laid andone contact of Cu tape withthickness of 0.1mm or Cu tapes laidwith overlap over each phase

Cable assembly Three insulated and screenesdphases are twisted with fillings andtape support

Inner sheatth PVC compound

Sheath PVC compound

type P-5 according to IBDS 2581

Color red

Technical data

324

Application

The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution ofelectrical power with nominal voltage Uo/U 3.6/6; 6/10; 12/20; 18/30; 20/35 kV and frequency 50 Hz in urban and districtelectrical networks and for electrical supply of transformer's substations, small and medium industrial plants.They are suitable for use in distribution installations, electric power stations and industrial systems.

The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduitsand shafts, over shelves and grills directly underground in ditch and outdoor shelter.

M I D D L E V O L T A

G E P O W E R C A B L E S - T H R E E C O R E

SHEmeTSAHEmeT

Uo/U - 3.6/6; 6/10; 12/20;18/30; 20/35 kVBDS 2581-86

Conductor resistance at20∞C

According toBDS904 (IEC60228) class 2

Operating temperature 90∞— continuous operation

Overload temperature 130∞— /100h per year max./

Short circuit temperature 250∞— /5 s max/

Nominal voltage Uo/U: 3.6/6;6/10;12/20;18/30;20/35kV

Highest system voltageUo/U, no more than

3.6/6; 6/10; 12/20; 18/30;20/35kV7.2kV;12kV; 24kV; 36kV; 42kV

Test voltage Uo/U AC (≈) - 5 min

DC (=) - 15min

3.6/6; 6/10; 12/20; 18/30;20/35kV11kV; 15kV; 30kV; 45kV; 50kV

29kV; 48kV; 96kV; 144kV; 160kV

Level of partial dis-charge at 2*Uo

Bending radius, min

Temperature of laying

max. 5 pC15x D cable

no less than -5∞—

Temperature ofexploitation

Tests-30 to 50∞—

according to BDS 2581

Force of strain in laying N

max.

where:

Al cores - 30*n*S coreCu cores - 50*n*S core

n- number of cores and-S-cross-section of conductorsin mm

E L KA B E L

Page 326: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 326/430

325

MI D D L E V O L T A G E P

O WE R C A B L E S

-T H R E E C O R E

Cu / Al conductors XLPE insulation Cu screen PVC sheath

Construction data SHEmeT, SAHEmeT 3.6/6; 6/10; 12/20; 18/30; 20/35 kV

Number of con-ductors and nom-inal cross section

Thicknessof insula-tion

Thicknessofsheath

Nominal

cross-sec-tion ofscreen

Cablediameterapprox.

Mass ofCu

approx.

Mass ofcable

approx.

Mass of Alapprox.

Mass ofCu

approx.

Mass ofcable

approx.

N ı mm2 mm mm mm2 mm kg/km kg/km kg/km kg/km kg/km

Uo/U 3.6/6kV

3x35rm/163x50rm/163x70rm/163x95rm/163x120rm/163x150rm/163x185rm/163x240rm/163x150rm/253x185rm/253x240rm/25Uo/U 6/10kV3x35rm/163x50rm/163x70rm/163x95rm/163x120rm/163x150rm/163x185rm/163x240rm/163x150rm/253x185rm/253x240rm/25

Uo/U 12/20kV

3x35rm/163x50rm/163x70rm/163x95rm/163x120rm/163x150rm/163x185rm/163x240rm/163x150rm/253x185rm/253x240rm/25

Uo/U 18/30kV

3x50rm/163x70rm/163x95rm/16

3x120rm/163x150rm/25

Uo/U 20/35kV

3x50rm/163x70rm/163x95rm/163x120rm/163x150rm/25

2.52.52.52.52.52.52.52.52.52.52.6

3.43.43.43.43.43.43.43.43.43.43.4

5.55.55.55.55.55.55.55.55.55.55.5

8.08.08.0

8.08.0

8.88.88.88.88.8

2.52.52.52.72.82.93.03.22.93.03.2

2.52.52.62.82.93.03.13.33.03.23.4

2.82.93.03.13.23.43.53.73.43.53.7

3.33.43.5

3.73.8

3.43.53.73.83.9

1616161616161616252525

1616161616161616252525

1616161616161616252525

161616

1625

1616161625

424448525558.562.568596368.5

4547.552.556.05962657262.565.573

55.557.5626668727682737783

707478

8286

7478828689

11551565212528253525436053356895445054256985

11551565212528253525436053356895445054256985

11551565212528253525436053356895445054256985

156521252825

35254450

15652125282535254450

2605307539004910578568608180102356940826510330

2905340542755305619572958655107307380874010815

3790434552456330727584759875120658565996512155

562566107790

881510185

607570808280934510720

2954055858101020125515602055125515602055

2954055858101020125515602055125515602055

2954055858101020125515602055125515602055

405585810

10201255

40558581010201255

176176176176176176176176265265265

176176176176176176176176265265265

176176176176176176176176265265265

176176176

176265

176176176176265

19302165259030853485402546355570410547205665

22302495296534803895510560605105519561507135

31153430393045004975563563307400572564207490

471052955960

65207345

51655765645570507885

SHEmeT SAHEmeT

E L KA B E L

Page 327: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 327/430

326

M I D D L E V O L T A

G E P O W E R C A

B L E S

E L KA B E L

Cable construction

Construction According to BDS 16291-85

Conductor —u and Al stranded compacted,according to BDS 904 (IEC60228)class 2

Insulation PVC compound

Cable assembly Three insulated phases are twisted

with fillings and tape support

Inner sheath Polymer material

Armour-screen Two steel tapes

Sheath PVC compound type P-1

Color gray

Technical data

Conductor resistance at20∞C

According toBDS904 (IEC60228) class 2

Operating temperature 70∞— continuous operation

Short circuit temperature 160∞— /5 s max/

Nominal voltage Uo/U: 3.6/6kV

Highest system voltage,no more than 7.2kV

Test voltage

AC (≈

) - 5 minDC (=) - 15 min 11kV29kV

Bending radius, min

Temperature of laying

15x D cable

no less than -5∞—

Temperature ofexploitation -30 to 50∞—

Force of strain in laying Nmax.

where:

Al cores - 30*n*ScoreCu cores - 50*n*S coren-number of cores and

S-cross section of cores inmm

Application

The three-core cables with insulation of polyvinylchloride (PVC) are designed for distribution of electrical power and forelectrical supply of consumers with nominal voltage Uo/U 3.6/6 kV and frequency 50 Hz.They are suitable for distribution installations, electric power stations and industrial systems.The cables are for fixed assembly in lines with unlimited difference levels, for indoor installations, in cable ducts, con-duits and shafts, over shelves and grills directly underground in ditch and outdoor shelter.

SVBT SAVBT Uo/U - 3.6/6 kVBDS 16291-85

Construction data SVBT, SAVBT 3.6/6 kV

Number ofconductors andnominal cross

section

Thickness ofinsulation

Armoursection

equivalent tocopper

Cable diameterapprox.

Mass ofCu

approx.

Mass ofcable approx.

Mass of Al

approx.

Mass ofcable approx.

N ı mm2 mm mm2 mm kg/km kg/km kg/km kg/km

Uo/U 3.6/6kV

3x25rm/63x35rm/63x50sm/63x70sm/63x95sm/63x120sm/63x150sm/6

3x185sm/63x240sm/6

3.43.43.43.43.43.43.4

3.43.4

6666666

66

37.740.043.242.645.648.651.6

55.160.0

70068013901950265033504185

51606720

2685315536004170508059806920

817510110

21029038558581010201255

15602035

2150253527002945338038184250

48305660

SVBT SAVBT

Page 328: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 328/430

Page 329: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 329/430

328

Application

These cables are designed for transfer and distribution of electrical power with nominal voltage U 0 / U 0 6/1 kV, fre-quency 50Hz and surroundings, which require non-proliferation of flames.

SVVn/A Uo/U - 0.6/1 kVFN KI 02.001

P O W E R C A

B L E S L O W

V O L T A

G E ,

F L A M E R E T A R

D A N T

Color coding

E L KA B E L

Number of cond. Color of conductors without yellow/green Color of conductors with yellow/green

1 random color -

2 brown, blue -

3 brown , black, blue, grey yellow/green, blue, brown

4 blue, brown, black, grey yellow/green, brown, black, grey

Neutral conductor - blue

Cable construction

Construction According to FN KI 02.001-96

Conductor Copper solid or twisted, class 1or class2, according toBDS 904-84 (IEC 60228)

Insulation PVC compound, according to

BDS 5792-84

Inner sheath Filling, flame retardant

Sheath PVC flame retardant, degree offlame retardancy category A

Color black

Technical data

Type codes

Cross section of conductor, mm2

class 1 from 1.5 to 16

class 2 from 25 to 500

Conductor resistance According to BDS 904-84

Test voltage

alternating 4kV

or direct 12kV

Temperature range

laying and installing -5oC

exploitation and storage -30oC to +50oC

Operating temperature +70oC

Short circuit temperature for nomore than 5 sec.

+160oC

Flame retardancy BDS IEC 332-3/82 Category ¿

Bending radius, min 10 ı D cable

S- power cable power cable

V- PVC insulation PVC insulation

Vn- sheath of PVCflame retardant sheath of PVC flame retardant

Page 330: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 330/430

329

P O W E R C A B L E S L O W

V O L T A G E ,F L A M E

R E T A R D A N T

Cu conductors PVC insulation PVC sheath

Construction data SVVn/¿ 0.6/1 kVNumber ofcond. andnominal

cross sec-tion

Form ofconductor

Cablediameterapprox.

Mass ofCu

Mass ofcable

approx

N ı mm2 mm kg/km kg/km

Construction data SVVn/¿ 0.6/1 kVNumber ofcond. andnominal

cross sec-tion

Form ofconductor

Cablediameterapprox.

Mass ofCu

Mass ofcable

approx

N ı mm2 mm kg/km kg/km

1 ı 1.5 re 8.0 14 741 ı 2.5 re 8.6 23 891 ı 4.0 re 9.5 37 1351 ı 6.0 re 10.0 55 1641 ı 10 re 11.7 93 2141 ı 16 re 12.6 148 2851 ı 25 rm 14.7 229 4251 ı 35 rm 15.8 325 5351 ı 50 rm 17.4 458 6921 ı 70 rm 19.1 648 9201 ı 95 rm 21.3 885 12251 ı 120 rm 22.8 1120 14851 ı 150 rm 24.7 1378 17931 ı 185 rm 26.9 1703 2200

1 ı 240 rm 30.0 2208 28301 ı 300 rm 30.7 2765 34851 ı 400 rm 34.1 3680 43901 ı 500 rm 38.1 4600 54782 ı 1.5 re 12.1 28 2102 ı 2.5 re 12.9 46 2482 ı 4.0 re 14.8 73 3402 ı 6.0 re 15.8 110 4102 ı 10 re 17.5 182 5252 ı 16 re 19.3 303 7142 ı 16 rm 20.2 303 7202 ı 25 rm 23.5 470 10852 ı 35 rm 25.7 652 13102 ı 50 rm 29.1 928 17202 ı 70 rm 33.1 1288 23302 ı 95 rm 37.9 1748 31303 ı 1.5 re 12.1 42 2303 ı 2.5 re 12.9 69 2903 ı 4.0 re 15.0 110 3843 ı 6.0 re 16.1 165 4733 ı 10 re 18.1 275 6423 ı 16 re 20.1 450 8733 ı 16 rm 20.9 450 9203 ı 25 rm 24.3 700 13523 ı 35 rm 26.7 980 17383 ı 50 rm 30.4 1390 23353 ı 50 sm 32.2 1400 23503 ı 70 sm 31.2 1950 26253 ı 95 sm 35.8 2650 35853 ı 120 sm 38.0 3350 43453 ı 150 sm 42.0 4185 53003 ı 185 sm 46.0 5160 65903 ı 240 sm 51.4 6720 8500

3 ı 2.5+1.5 re/re 14.5 82 3163 ı 4.0+2.5 re/re 15.6 132 4353 ı 6.0+4.0 re/re 17.0 202 5503 ı 10+6.0 re/re 18.8 330 7383 ı 16+10 re/re 21.0 540 10083 ı 25+16 rm/re 25.4 850 15693 ı 25+16 rm/rm 25.6 850 15703 ı 35+16 rm/re 27.7 1130 19753 ı 35+16 rm/rm 27.7 1131 19763 ı 35+16 sm/re 28.0 1141 19863 ı 50+25 rm/rm 32.2 1630 25953 ı 70+35 sm/rm 36.0 2280 31553 ı 95+50 sm/rm 40.1 3120 41953 ı 120+70 sm/rm 43.2 4010 51803 ı 150+70 sm/rm 48.0 4850 64203 ı 185+95 sm/rm 52.3 6070 77713 ı 240+120 sm/rm 58.7 7840 99903 ı 300+150 sm/rm 64.3 9928 12466

4 ı 1.5 re 12.9 55 2704 ı 2.5 re 13.8 92 3294 ı 4.0 re 16.2 146 455

4 ı 6.0 re 17.4 218 5694 ı 10 re 19.5 363 7824 ı 16 re 21.8 582 11624 ı 16 rm 23.0 588 11984 ı 25 rm 27.2 925 16904 ı 35 rm 30.1 1303 21904 ı 50 rm 34.8 1857 29784 ı 70 rm 39.1 2592 39374 ı 95 rm 45.3 3540 53174 ı 35 sm 28.0 1303 29804 ı 50 sm 31.2 1857 39404 ı 70 sm 36.0 2601 34904 ı 95 sm 40.2 3540 46604 ı 120 sm 43.3 4460 5680

4 ı 150 sm 48.2 5575 70354 ı 185 sm 53.8 6880 88954 ı 240 sm 58.8 8928 112554 ı 300 sm 64.4 11060 13722

E L KA B E L

Page 331: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 331/430

330

Application

These cables are designed for transfer and distribution of electrical power with nominal voltage U 0 / U 0 6/1 kV, fre-quency 50Hz and surroundings, which require non-proliferation of flames.

SVVn/A Uo/U - 0.6/1 kVFN KI 02.001-96

P O W E R C A

B L E S L O W

V O L T A

G E ,

F L A M E R E T A R

D A N T

Color coding

Number of cond. Color of conductors without yellow/green Color of conductors with yellow/green

5 blue, brown, black, grey, black yellow/green, blue, brown, black,grey

6 and over 6 black with number marking

yellow/green and the other black with number

marking

Cable construction

Construction According to FN KI 02.001-96

Conductor Copper solid or twisted, class 1 or 2,

according to BDS 904-84 (IEC 60228)

Insulation PVC insulation according to

BDS 5792-84

Inner sheath filling, flame retardant

Sheath PVC flame retardant, degree of flame

retardant category A

Color black

Technical data

Type codes

Cross section of conductor, mm2

class 1 from 1.5 to 16

class 2 from 25 to 500

Conductor resistance According to BDS 904-84

Test voltage

alternating 4kV

or direct 12kV

Temperature range

laying and installing -5oC

exploitation and storage -30oC to +50oC

Operating temperature +70oC

Short circuit temperature for nomore than 5 sec.

+160oC

Flame retardancy BDS IEC 332-3/82 Category ¿

Bending radius, min 10 ı D cable

S- power cable

V- PVC insulation

Vn- sheath of PVC flame retardant

E L KA B E L

Page 332: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 332/430

331

P O W E R C A B L E S L O W

V O L T A G E ,F L A M E

R E T A R D A N T

Cu conductors PVC insulation PVC sheath

Construction data SVVn/¿ 0.6/1 kV

Number of cond. and nomi-nal cross section

Form ofconductor

Cable diameterapprox. Mass of Cu Mass of cable

approx

N ı mm2 mm kg/km kg/km

5 ı 1.5 re 13.9 69 3055 ı 2.5 re 14.8 114 3805 ı 4.0 re 17.6 182 5405 ı 6.0 re 19.1 275 6805 ı 10 re 21.7 455 9395 ı 16 re 24.2 745 13185 ı 16 rm 25.2 745 13285 ı 25 rm 30.2 1165 20905 ı 35 rm 33.6 1640 27405 ı 50 rm 38.2 2330 36705 ı 70 rm 43.4 3260 48755 ı 95 rm 50.2 4430 65506 ı 1.5 re 15.5 84 3566 ı 2.5 re 16.6 138 446

6 ı 4.0 re 20.2 222 6426 ı 6.0 re 21.1 330 8056 ı 10 re 23.5 558 11227 ı 1.5 re 14.8 96 3457 ı 2.5 re 16.6 160 4357 ı 4.0 re 19.5 255 6718 ı 1.5 re 16.1 110 3998 ı 2.5 re 17.4 182 5028 ı 4.0 re 21.5 296 84510 ı 1.5 re 18.6 140 46210 ı 2.5 re 19.8 228 58810 ı 4.0 re 23.9 365 99112 ı 1.5 re 18.4 165 51012 ı 2.5 re 19.8 275 66012 ı 4.0 re 24.6 444 108614 ı 1.5 re 19.2 195 56714 ı 2.5 re 20.8 320 740

14 ı 4.0 re 25.8 518 120716 ı 1.5 re 19.9 220 63116 ı 2.5 re 21.8 365 82719 ı 1.5 re 21.2 260 70619 ı 2.5 re 22.9 435 93820 ı 1.5 re 22.1 280 77520 ı 2.5 re 24.1 460 102521 ı 1.5 re 21.2 294 79921 ı 2.5 re 24.2 483 106024 ı 1.5 re 24.5 330 86224 ı 2.5 re 26.4 546 115525 ı 1.5 re 24.6 350 90525 ı 2.5 re 26.5 575 118827 ı 1.5 re 24.6 378 111027 ı 2.5 re 26.8 621 134730 ı 1.5 re 25.5 410 111830 ı 2.5 re 27.8 685 137537 ı 1.5 re 27.2 506 120537 ı 2.5 re 30.2 845 1655

E L KA B E L

Page 333: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 333/430

332

Application

These cables are designed for transfer and distribution of electrical power with nominal voltage U 0 / U 0 6/1 kV, fre-quency 50Hz and surroundings, which require non-proliferation of flames.

SVVn/C Uo/U - 0.6/1 kVFN KI 02.001-2006

P O W E R C A

B L E S L O W

V O L T A

G E ,

F L A M E R E T A R

D A N T

Color coding

E L KA B E L

Number of cond. Color of conductors without yellow/green Color of conductors with yellow/green

1 random color -

2 light blue; brown -

3 brown, black, grey yellow/green, blue, brown

4 blue, brown, black, grey yellow/green, brown, black, grey

Neutral conductor - blue

Cable construction

Construction According to FN KI 02.001-96

Conductor Copper solid or twisted, class 1or class2, according toBDS 904-84 (IEC 60228)

Insulation PVC compound, according toBDS 5792-84

Sheath PVC flame retardant, degree offlame retardancy category C

Color black

Technical data

Cross section of conductor, mm2

class 1 from 1.5 to 16

class 2 from 25 to 500

Conductor resistance According to BDS 904-84

Test voltage

alternating 4kV

or direct 12kV

Temperature range

laying and installing -5oC

exploitation and storage -30oC to +50oC

Operating temperature +70oC

Short circuit temperature for nomore than 5 sec.

+160oC

Flame retardancy BDS IEC 332-3/82 Category C

Bending radius, min 10 ı D cable

S- power cable

V- PVC insulation

Vn- sheath of PVC flame retardant

Type codes

Page 334: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 334/430

333

P O W E R C A B L E S L O W

V O L T A G E ,F L A M E

R E T A R D A N T

Cu conductors PVC insulation PVC sheath

Construction data SVVn/C 0.6/1 kVNumber ofcond. andnominal

cross sec-tion

Form ofconductor

Cablediameterapprox.

Mass ofCu

Mass ofcable

approx

N ı mm2 mm kg/km kg/km

Construction data SVVn/C 0.6/1 kVNumber ofcond. andnominal

cross sec-tion

Form ofconductor

Cablediameterapprox.

Mass ofCu

Mass ofcable

approx

N ı mm2 mm kg/km kg/km

1 ı 1.5 re 7.2 14 691 ı 2.5 re 7.6 23 821 ı 4 re 8.0 37 1021 ı 6 re 8.5 55 1251 ı 10 re 9.3 93 1781 ı 16 re 10.8 148 2531 ı 16 Ím 10.8 148 2531 ı 25 rm 11.9 229 3501 ı 35 rm 13.0 325 4621 ı 50 rm 14.2 458 5981 ı 70 rm 16.7 648 8101 ı 95 rm 18.4 885 11001 ı 120 rm 19.9 1120 1385

1 ı 150 rm 21.9 1378 16101 ı 185 rm 24.3 1703 20201 ı 240 rm 27.2 2208 25651 ı 300 rm 30.3 2765 32001 ı 400 rm 33.8 3680 40351 ı 500 rm 37.9 4600 51802 ı 1.0 re 9.3 20 1002 ı 1.5 re 10.0 28 1202 ı 2.5 re 10.6 46 1502 ı 4 re 12.1 75 2102 ı 6 re 13.2 110 2602 ı 10 re 15.2 182 3702 ı 16 re 17.8 303 5582 ı 25 rm 21.5 470 8102 ı 35 rm 23.8 652 1057

2 ı 50 rm 27.0 928 14083 ı 1.0 re 9.6 28 1193 ı 1.5 re 10.2 42 1223 ı 2.5 re 11.0 69 1543 ı 4 re 12.8 110 2603 ı 6 re 14.0 165 3493 ı 10 re 16.0 275 4803 ı 16 re 18.9 450 6823 ı 25 rm 22.8 700 10783 ı 35 rm 25.3 980 1298

3 ı 50 rm 28.9 1390 18953 ı 70 sm 28.8 1950 24003 ı 95 sm 33.1 2650 32253 ı 120 sm 35.9 3350 40103 ı 150 sm 39.3 4185 48303 ı 185 sm 43.4 5160 60353 ı 240 sm 48.9 6720 7818

3 ı 2.5 + 1.5 re+re 11.2 82 2033 ı 4,0 + 2.5 re+re 13.4 132 2933 ı 6,0 + 4,0 re+re 14.4 202 3803 ı 10 + 6 re+re 16.7 330 5453 ı 16 + 10 re+re 19.5 540 8703 ı 25 + 16 rm+re 24.4 850 1245

3 ı 35 + 16 rm+re 27.1 1130 15903 ı 50 + 25 rm+rm 30.8 1630 21753 ı 70 + 35 sm+rm 31.8 2280 27853 ı 95 + 50 sm+rm 36.8 3120 36803 ı 120 + 70 sm+rm 40.1 4010 47303 ı 150 + 70 sm+rm 44.3 4850 56203 ı 185 + 95 sm+rm 49.3 6070 70903 ı 240 + 120 sm+rm 55.4 7840 9150

4 ı 1.0 re 10.4 37 1404 ı 1.5 re 11.0 55 1654 ı 2.5 re 11.9 92 2164 ı 4 re 13.6 146 3174 ı 6 re 14.4 218 4084 ı 10 re 16.8 363 5934 ı 16 re 19.2 582 951

4 ı 25 rm 25.2 925 12854 ı 35 rm 28.0 1303 17784 ı 50 rm 32.0 1857 23074 ı 70 sm 33.0 2601 31014 ı 95 sm 37.3 3540 42504 ı 120 sm 41.2 4460 52104 ı 150 sm 45.2 5575 63854 ı 185 sm 49.5 6880 79604 ı 240 sm 56.4 8928 10310

E L KA B E L

Page 335: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 335/430

Cable construction

Construction According to FN KI 02.001-96

Conductor Aluminum solid or twisted cores,class 1 or class 2, according toBDS 904-84

Insulation PVC insulation, according toBDS 5792-84

Inner sheath Flame retardant filling

Sheath PVC flame retardant, degree offlame retardant category A

Color black

Technical data

334

Application

These cables are designed for transfer and distribution of electrical power with nominal voltage U 0 / U 0 6/1 kV, fre-quency 50Hz and surroundings, which require non-proliferation of flames

SAVVn/¿ Uo/U - 0.6/1 kVFN KI 02.001-96

P O W E R C A

B L E S L O W

V O L T A

G E ,

F L A M E R E T A R

D A N T

Color coding

Cross section of conductor, mm2

class 1 from 1.5 to 16

class 2 from 25 to 500

Conductor resistance According to BDS 904-84

Test voltage

alternating 4kV

or direct 12kV

Temperature range

laying and installing -5oC

exploitation and storage -30oC to +50oC

Operating temperature +70oC

Short circuit temperature for nomore than 5 sec.

+160oC

Flame retardancy BDS IEC 332-3/82 Category A

Bending radius, min 10 ı D cable

S- power cable

A- aluminum conductors V- PVC insulation

Vn- sheath of PVC flame retardant

Number of cond. Color of conductors without yellow/green Color of conductors with yellow/green

1 random color -

2 brown, blue -

3 brown , black, blue, grey yellow/green, blue, brown

4 blue, brown, black, grey yellow/green, brown, black, blue

5 blue, brown, black, grey, black yellow/green, blue, brown, black, grey

Neutral conductor - blue

Type codes

E L KA B E L

Page 336: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 336/430

335

P O W E R C A B L E S L O W

V O L T A G E ,F L A M E

R E T A R D A N T

Al conductors PVC insulation PVC sheath

Construction data SAVVn/¿ 0.6/1 kV

Number ofcond. andnominal

cross sec-tion

Form ofconductor

Cablediameterapprox.

Mass of Al

Mass ofcable

approx

N ı mm2 mm kg/km kg/km

Construction data SAVVn/¿ 0.6/1 kV

Number ofcond. andnominal

cross sec-tion

Form ofconductor

Cablediameterapprox.

Mass of Al

Mass ofcable

approx

N ı mm2 mm kg/km kg/km

1 ı 2.5 re 7.5 8 721 ı 4 re 8.4 12 931 ı 6 re 9.1 17 1071 ı 10 re 9.1 28 1281 ı 16 re 10.6 45 1581 ı 25 re 12.2 68 2101 ı 35 re 13.2 95 2521 ı 50 re 14.6 127 3151 ı 50 rm 17.4 127 3301 ı 70 rm 19.2 190 5221 ı 95 rm 21.4 260 6481 ı 120 rm 22.8 325 7551 ı 150 rm 24.7 405 882

1 ı 185 rm 24.9 510 9251 ı 240 rm 30.1 665 13251 ı 300 rm 30.6 830 14021 ı 400 rm 34.0 1060 17481 ı 500 rm 38.1 1410 22352 ı 2.5 re 12.9 14 2182 ı 4 re 14.9 23 2922 ı 6 re 16.1 34 3462 ı 10 re 17.4 56 4072 ı 16 re 19.3 90 5102 ı 25 re 22.4 137 6952 ı 35 re 24.3 190 8322 ı 35 rm 25.4 190 8832 ı 50 rm 29.1 254 11602 ı 70 rm 33.1 380 1517

2 ı 95 rm 37.9 520 19953 ı 2.5 re 13.5 21 2403 ı 4 re 15.6 36 3263 ı 6 re 17.0 51 3853 ı 10 re 18.3 85 4653 ı 16 re 20.4 135 5823 ı 25 re 23.7 210 7903 ı 35 re 25.8 290 9663 ı 50 re 29.2 385 12403 ı 50 rm 31.0 385 13103 ı 70 rm 32.0 570 17613 ı 95 rm 40.4 780 22953 ı 50 sm 27.8 385 10353 ı 70 sm 31.2 585 13513 ı 95 sm 35.8 810 18053 ı 120 sm 38.0 1020 20593 ı 150 sm 41.8 1255 25303 ı 185 sm 45.8 1560 31073 ı 240 sm 51.2 2035 3905

3 ı 4+2.5 re/re 16.2 42 3483 ı 6+4 re/re 17.9 63 425

3 ı 10+6 re/re 19.4 101 5103 ı 16+10 re/re 21.5 165 6453 ı 25+16 re/re 24.9 255 8783 ı 35+16 re/re 26.7 340 10403 ı 50+25 re/re 30.5 480 13743 ı 50+25 rm/re 32.6 485 14753 ı 50+25 rm/Ím 28.8 485 14953 ı 70+35 rm/Ím 37.0 665 18993 ı 70+35 rm/rm 36.6 660 18893 ı 95+50 rm /rm 42.3 907 24953 ı 35+16 sm/re 28.0 340 9773 ı 50+25 sm/re 31.2 453 12253 ı 70+35 sm/rm 36.0 670 1637

3 ı 95+50 sm/rm 40.2 910 20863ı120+70 sm/rm 43.2 1180 24763ı150+70 sm/rm 48.0 1405 29993ı185+95 sm/rm 52.3 1780 36473ı240+120 sm/rm 58.7 2310 45983ı300+150 sm/rm 64.3 2895 5577

4 ı 2.5 re 14.4 28 2694 ı 4 re 16.8 46 3754 ı 6 re 18.3 68 4454 ı 10 re 19.8 112 5404 ı 16 re 22.1 180 6934 ı 25 re 25.8 270 9444 ı 35 re 28.2 390 11634 ı 50 re 32.5 520 15374 ı 50 rm 34.7 520 1660

4 ı 70 rm 39.1 760 21344 ı 95 rm 45.2 1040 28514 ı 35 sm 28.0 390 10504 ı 50 sm 31.2 520 13214 ı 70 sm 36.0 760 17634 ı 95 sm 40.2 1060 22764 ı 120 sm 43.2 1340 26784 ı 150 sm 48.0 1650 31054 ı 185 sm 53.7 2100 42684 ı 240 sm 58.7 2720 51204 ı 300 sm 64.3 3320 61575 ı 2.5 re 15.4 35 3095 ı 4 re 18.1 58 4295 ı 6 re 19.7 85 5135 ı 10 re 21.4 140 6305 ı 16 re 24.0 225 7955 ı 25 re 28.1 345 11205 ı 35 rm 33.0 480 15205 ı 50 rm 38.1 650 19835 ı 70 rm 43.3 965 26045 ı 95 rm 49.8 1345 3497

E L KA B E L

Page 337: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 337/430

336

Application

Armored cable for fixed installation and construction of electrical networks and installations, intended for transfer anddistribution of electrical power with nominal voltage U 0 / U 0. 6/1 kV, frequency of 50Hz and flame retardant surround-ings. Armored cable for fixed installation and construction of electrical networks and installations, intended for transferand distribution of electrical power with nominal voltage U 0 / U 0. 6/1 kV, frequency of 50Hz and flame retardant sur-roundings.

SVBVn/A Uo/U - 0.6/1 kVFN KI 02.001-96

P O W E R C A

B L E S L O W

V O L T A

G E ,

F L A M E R E T A R

D A N T

E L KA B E L

Cable construction

Construction According to FN KI 02.001-96

Conductor Copper solid or twisted cores,class 1 or class 2, according toBDS 904-84(IEC 60228)

Insulation PVC insulation, according to

BDS 5792-84

Inner sheath flame retardant filling

Armour steel tapes

Sheath PVC flame retardant, degree offlame retardancy category A

Color black

Technical data

Color coding

Cross section of conductor, mm2

class 1 from 1.5 to 16

class 2 from 25 to 500

Conductor resistance According to BDS 904-84

Test voltage

alternating 4kV

or direct 12kV

Temperature range

laying and installing -5oC

exploitation and storage -30oC to +50oC

Operating temperature +70oC

Short circuit temperature for nomore than 5 sec.

+160oC

Flame retardancy BDS IEC 332-3/82 Category A

Bending radius, min 10 ı D cable

Number of cond. Color of conductors without yellow/green Color of conductors with yellow/green

1 random color -

2 brown, blue -

3 brown , black, blue, grey yellow/green, blue, brown

4 blue, brown, black, grey yellow/green, brown, black, grey

Neutral conductor - blue

S- power cable

V- PVC insulationB- armor

Vn- sheath of PVC flame retardant

Type codes

Page 338: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 338/430

337

P O W E R C A B L E S L O W

V O L T A G E ,F L A M E

R E T A R D A N T

Cu conductors PVC insulation Armour-st. tapes PVC sheath

Construction data SVBVn/A 0.6/1 kV

Number of cond. and nomi-nal cross section

Form ofconductor

Cable diameterapprox. Mass of Cu Mass of cable

approx

N ı mm2 mm kg/km kg/km

2 ı 1.5 re 12.8 28 3152 ı 2.5 re 13.0 46 3602 ı 4.0 re 16.2 73 4782 ı 6.0 re 17.2 110 5612 ı 10 re 18.8 182 6802 ı 16 re 20.6 303 8622 ı 25 rm 25.1 470 12992 ı 35 rm 27.4 652 15702 ı 50 rm 31.0 928 20163 ı 1.5 re 13.7 42 3503 ı 2.5 re 14.5 69 4203 ı 4.0 re 16.7 110 5293 ı 6.0 re 18.0 165 631

3 ı 10 re 20.0 275 8203 ı 16 re 22.0 450 10223 ı 25 rm 26.5 700 15553 ı 35 rm 29.2 980 20233 ı 50 rm 32.8 1390 26483 ı 70 sm 33.0 1950 29403 ı 95 sm 38.0 2650 39843 ı 120 sm 40.0 3350 47863 ı 150 sm 44.2 4185 58413 ı 185 sm 47.9 5160 71253 ı 240 sm 53.3 6720 90983 ı 300 sm 58.7 8295 11198

3 ı 2.5+1.5 re/re 16.2 82 4613 ı 4.0+2.5 re/re 17.8 132 6183 ı 6.0+4.0 re/re 19.2 202 699

3 ı 10+6.0 re/re 21.1 330 9223 ı 16+10 re/re 23.2 540 12233 ı 25+16 rm/re 27.6 850 18053 ı 25+16 rm/rm 27.8 850 18123 ı 35+16 rm/rm 30.1 1131 22663 ı 50+25 rm/rm 34.2 1630 29783 ı 50+25 sm/rm 34.2 1630 29783 ı 70+35 sm/rm 38.2 2280 35423 ı 95+50 sm/rm 42.4 3120 45383 ı 120+70 sm/rm 45.6 4010 55963 ı 150+70 sm/rm 50.2 4850 69333 ı 185+95 sm/rm 54.4 6070 83563 ı 240+120 sm/rm 60.9 7840 106203 ı 300+150 sm/rm 66.7 9928 13422

4 ı 1.5 re 14.5 55 390

4 ı 2.5 re 15.7 92 4664 ı 4.0 re 18.3 146 6214 ı 6.0 re 19.5 218 7344 ı 10 re 21.5 363 9754 ı 16 re 23.7 582 12754 ı 25 rm 29.0 925 19384 ı 35 rm 31.8 1303 25224 ı 50 rm 36.7 1857 33354 ı 50 sm 33.0 1857 33384 ı 70 sm 38.2 2601 38454 ı 95 sm 42.4 3540 51324 ı 120 sm 45.6 4460 62504 ı 150 sm 50.2 5575 77404 ı 185 sm 54.5 6880 95104 ı 240 sm 61.0 8928 119284 ı 300 sm 66.7 11060 14655

E L KA B E L

Page 339: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 339/430

338

Application

Armored cable for fixed installation and construction of electrical networks and installations, intended for transfer anddistribution of electrical power with nominal voltage U 0 / U 0. 6/1 kV, frequency of 50Hz and flame retardant surround-ings. Armored cable for fixed installation and construction of electrical networks and installations, intended for transferand distribution of electrical power with nominal voltage U 0 / U 0. 6/1 kV, frequency of 50Hz and flame retardant sur-roundings.

SVBVn/A Uo/U - 0.6/1 kVFN KI 02.001-96

P O W E R C A

B L E S L O W

V O L T A

G E ,

F L A M E R E T A R

D A N T

Cable construction

Construction According to FN KI 02.001-96

Conductor Copper solid or twisted cores,class 1 or class 2, according toBDS 904-84(IEC 60228)

Insulation PVC insulation, according to

BDS 5792-84

Inner sheath flame retardant filling

Armour steel tapes

Sheath PVC flame retardant, degree offlame retardancy category A

Color black

Technical data

Color coding

Cross section of conductor, mm2

class 1 from 1.5 to 16

class 2 from 25 to 500

Conductor resistance According to BDS 904-84

Test voltage

alternating 4kV

or direct 12kV

Temperature range

laying and installing -5oC

exploitation and storage -30oC to +50oC

Operating temperature +70oC

Short circuit temperature for nomore than 5 sec.

+160oC

Flame retardancy BDS IEC 332-3/82 Category A

Bending radius, min 10 ı D cable

Number of cond. Color of conductors without yellow/green Color of conductors with yellow/green

5 blue, brown, black, grey, black yellow/green, blue, brown, black,grey

6 and over 6 black with number marking yellow/green and the other core black with

number marking

S- power cable

V- PVC insulationB- armor

Vn- sheath of PVC flame retardant

Type codes

E L KA B E L

Page 340: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 340/430

339

P O W E R C A B L E S L O W

V O L T A G E ,F L A M E

R E T A R D A N T

Cu conductors PVC insulation Armour-st. tapes PVC sheath

Construction data SVBVn/A 0.6/1 kV

Number of cond. and nomi-nal cross section

Form ofconductor

Cable diameterapprox. Mass of Cu Mass of cable

approx

N ı mm2 mm kg/km kg/km

5 ı 1.5 re 15.9 69 4305 ı 2.5 re 16.9 114 5205 ı 4.0 re 19.5 182 7105 ı 6.0 re 15.7 275 8565 ı 10 re 23.1 455 10255 ı 16 re 25.6 745 13205 ı 25 rm 31.7 1165 23405 ı 35 rm 34.8 1640 31255 ı 50 rm 40.1 2330 41805 ı 70 rm 45.3 3260 52006 ı 1.5 re 16.8 84 5076 ı 2.5 re 18.0 138 6086 ı 4.0 re 20.9 222 835

6 ı 6.0 re 22.4 330 10137 ı 1.5 re 16.8 96 5027 ı 2.5 re 18.0 160 6307 ı 4.0 re 20.9 255 8657 ı 6.0 re 22.4 384 10558 ı 1.5 re 19.1 110 5788 ı 2.5 re 19.6 182 7158 ı 4.0 re 22.9 296 10208 ı 6.0 re 23.5 440 125010 ı 1.5 re 20.1 140 66510 ı 2.5 re 21.5 228 81410 ı 4.0 re 25.4 365 122510 ı 6.0 re 27.4 550 152012 ı 1.5 re 20.4 165 74112 ı 2.5 re 22.1 275 890

14 ı 1.5 re 21.2 195 80514 ı 2.5 re 22.9 320 96016 ı 1.5 re 22.1 220 88016 ı 2.5 re 23.9 365 108019 ı 1.5 re 23.1 260 93019 ı 2.5 re 25.0 435 121520 ı 1.5 re 24.1 280 105520 ı 2.5 re 26.1 460 131021 ı 1.5 re 24.1 294 106521 ı 2.5 re 26.1 483 132024 ı 1.5 re 26.1 330 113524 ı 2.5 re 28.6 546 148527 ı 1.5 re 26.6 378 129527 ı 2.5 re 29.2 621 167230 ı 1.5 re 27.5 410 1460

30 ı 2.5 re 24.8 685 172037 ı 1.5 re 29.4 506 156637 ı 2.5 re 32.3 845 1986

E L KA B E L

Page 341: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 341/430

340

SAVBVn/A Uo/U - 0.6/1 kVFN KI 02.001-96

P O W E R C A

B L E S L O W

V O L T A

G E ,

F L A M E R E T A R

D A N T

Cable construction

Construction According to FN KI 02.001-96

Conductor Aluminum solid or twisted cores,class 1 or class 2, according toBDS 904-84

Insulation PVC insulation, according toBDS 5792-84

Inner sheath flame retardant filling

Sheath PVC flame retardant, degree of flameretardant category A

Color black

Technical data

Cross section of conductor, mm2

class 1 from 1.5 to 16

class 2 from 25 to 500

Conductor resistance According to BDS 904-84

Test voltage

alternating 4kV

or direct 12kV

Temperature range

laying and installing -5oC

exploitation and storage -30oC to +50oC

Operating temperature +70oC

Short circuit temperature for no

more than 5 sec.+160oC

Flame retardancy BDS IEC 332-3/82 Category A

Bending radius, min 10 ı D cable

S- power cable

A- aluminum conductors

V- PVC insulation

B- Steel tape armor Vn- sheath of PVC flame retardant

Type codes

Number of cond. Color of conductors without yellow/green Color of conductors with yellow/green

1 random color -

2 brown, blue -

3 brown , black, blue, grey yellow/green, blue, brown

4 blue, brown, black, grey yellow/green, brown, black, grey

5 blue, brown, black, grey, black yellow/green, blue, brown, black,grey

6 and above black with number marking yellow/green and the other core black with num-ber marking

Application

Armored cables for fixed assembly installation of electrical power networks and installations, designed for transfer anddistribution of electrical power with nominal voltage U 0 / U 0 6/1 kV, frequency 50Hz and surroundings, which requirenon-proliferation of flames.

Color coding

E L KA B E L

Page 342: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 342/430

341

P O W E R C A B L E S L O W

V O L T A G E ,F L A M E

R E T A R D A N T

Al conductors PVC insulation Armour-st. tapes PVC sheath

Construction data SAVBVn/A 0.6/1 kV

Number ofcond. andnominal

cross sec-tion

Form ofconductor

Cablediameterapprox.

Massof

Alapprox.

Mass ofcable

approx.

N ı mm2 mm kg/km kg/km

Construction data SAVBVn/A 0.6/1 kV

Number ofcond. andnominal

cross sec-tion

Form ofconductor

Cablediameterapprox.

Massof

Alapprox.

Mass ofcable

approx.

N ı mm2 mm kg/km kg/km

2 ı 2.5 re 16.4 14 4332 ı 4.0 re 16.5 23 4402 ı 6.0 re 17.5 34 4992 ı 10 re 19.1 56 5932 ı 16 re 21.0 90 7192 ı 25 rm 25.1 137 9952 ı 35 rm 27.4 190 11742 ı 50 rm 30.7 254 14683 ı 2.5 re 16.3 21 4303 ı 4.0 re 17.2 36 4813 ı 6.0 re 18.3 51 5403 ı 10 re 20.1 85 6513 ı 16 re 22.1 135 794

3 ı 25 rm 26.6 210 11043 ı 35 rm 29.1 290 13243 ı 50 rm 32.8 385 16523 ı 50 sm 29.6 385 13253 ı 70 sm 33.0 585 16653 ı 95 sm 38.0 810 25483 ı 120 sm 40.0 1020 26533 ı 150 sm 44.2 1255 31943 ı 185 sm 47.9 1560 37803 ı 240 sm 53.3 2035 46623 ı 300 sm 58.7 2490 5530

3ı4.0+2.5 re/re 12.6 42 4963ı6.0+4.0 re/re 19.2 63 5793 ı 10+6.0 re/re 21.0 101 6943 ı 16+10 re/re 23.2 165 887

3 ı 25+16 re/re 27.8 255 11853 ı 35+16 re/re 27.1 340 12053 ı 35+16 rm/rm 30.1 340 13963 ı 50+25 rm/rm 34.2 480 17913 ı 50+25 sm/rm 33.0 480 15723 ı 50+35 sm/rm 33.0 507 16043 ı 70+35 sm/rm 38.2 670 21943 ı 95+50 sm/rm 42.4 910 26843ı120+70 sm/rm 45.6 1180 31643ı150+70 sm/rm 50.2 1405 3721

3ı185+95 sm/rm 54.5 1780 44253ı240+120 sm/rm 60.9 2310 54603ı300+150 sm/rm 66.7 2895 6554

4 ı 2.5 re 16.4 28 4314 ı 4.0 re 18.4 46 5394 ı 6.0 re 19.6 68 6134 ı 10 re 21.5 112 7494 ı 16 re 23.8 180 9214 ı 25 re 29.1 270 13054 ı 35 re 31.9 390 28744 ı 50 re 36.7 520 50704 ı 70 sm 38.2 760 23104 ı 95 sm 42.4 1060 2884

4 ı 120 sm 45.6 1340 33584 ı 150 sm 50.2 1650 40314 ı 185 sm 54.5 2100 48224 ı 240 sm 60.9 2720 59804 ı 300 sm 66.7 3320 70985 ı 1.5 re 15.9 25 4155 ı 2.5 re 16.8 35 4615 ı 4.0 re 19.6 58 6075 ı 6.0 re 21.0 85 6965 ı 10 re 23.2 140 8525 ı 16 re 25.7 225 10565 ı 25 rm 31.7 345 15195 ı 35 rm 34.9 480 18375 ı 50 rm 40.1 650 25715 ı 70 rm 45.3 950 3265

7 ı 1.5 re 16.9 35 4568 ı 1.5 re 18.3 40 52810 ı 1.5 re 19.9 51 62512 ı 1.5 re 20.4 61 65114 ı 1.5 re 21.2 71 70616 ı 1.5 re 22.1 81 74819 ı 1.5 re 23.0 95 80720 ı 1.5 re 24.0 101 87021 ı 1.5 re 24.0 105 87324 ı 1.5 re 26.1 120 1021

E L KA B E L

Page 343: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 343/430

342

H I G H F R E Q U E N C Y

C O M M U N I C A T I O N

S C A B L E S F O R T R

U N K C A B L E N E T W

O R K S

E L KA B E L

MKG . . . x4x1.2Paper band insulation quads, stranded in layers lead sheath

BDS 5052-90.

Number of quadsNumber of quads in the layers

1 2

3 3

4 4

7 1 6

Cable construction

Conductor Bare copper conductor, diameter1.2mm

Insulation Paper string insulation, over whichthere is a paper tape

Quad 4 wires are twisted into a quadCable core Quads are stranded into layers

Wrapping Several layers of paper tapesSheath Lead containing antimony of 0.4 to

0.6%

Technical data

Color coding

Type codesM trunk cableK paper band insulationG no protective sheath

Conductor diameter 1.2mm

Resistance of side circuit at20oC-max 31.7 Ω/km

Ohmic asymmetry - max. 0.13/425m

Insulation resistance - min. 12 000 MΩ.km

Mutual capacitance at 800Hz-nom. 26.5nF/km

Attenuation of near end betweenall side-circuits at 552kHz no

less than90% of all combinations100% of all combinations

62dB/42557dB/425m

Protection of far end between allside-circuit at 552kHz no less

than90% of all combinations100% of all combinations

70dB/425m66dB/425m

Test voltage 50Hz, 2 min.wire-wire

wire-sheath1000V2000V

Operating voltage peak value 225V

Temperature rangelaying and installing

exploitation and storage-20oC äî +50oC-30oC äî +70oC

Bending radius, min. approx. 20 õ D cable

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad markingIn each layer there is a quad with red supportingspiral from which the counting starts and a quadshowing the direction of counting - with yellow

supporting spiral

Application

These cables are used for building trunk cables networks with the possibility for sealing the transmitted signals up to552 kHz. They are intended for fixed installation in collectors, canals or pipes.The use of these cables for high power installations and for direct laying in ground is not permitted.

Cable core construction

Construction data MKG...x4x1.2

Number of quads Outer diameter approx Copper weight Cable weight approx

mm kg/km kg/km

3 18.8 134 1049

4 19.8 179 11467 25.1 313 1678

Page 344: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 344/430

343

H I G H

F R E Q U E N C Y C O M

M U N I C A T I O N S C A

B L E S F O R T R U N K

C A B L E N E T W O R K

S

E L KA B E L

MKBs . . . x4x1.2BDS 5052-90

Cable construction

Conductor Bare copper conductor diameter1.2mm

Insulation Paper string insulation, over whichthere is a paper tape

Quad 4 cores are twisted into quadCable core Quads are twisted concentrically

into layers Wrapping Several layers of paper tapesSheath of lead, containing antimony of 0.4

to 0.6%Pad Bitumen and impregnated cable

paper Armour Two steel tapesProtective of bitumen, synthetic yarncovering and chalk

Color coding

Application

These cables are used for construction of trunk cable communication network and connection lines between automatictelephone exchanges, with the possibility for using multi-channel systems with a frequency range of up to 552 kHz.They are suitable for laying in ditches, where there is less force of strain and inclined terrain less than 45Ó.The use of these cables for power installations high voltage is not permitted.

Paper band insulation quads stranded in layers lead sheath armour of steel tapes

protective layer of yarn

Technical data

Conductor diameter 1.2mm

Resistance of side circuits at20oC-max 31.7 Ω/km

Ohmic asymmetry - max. 0.13/425m

Insulation resistance - min. 12 000 MΩ.km

Mutual capacitance at 800Hz-nom. 26.5nF/km

Attenuation of near end betweenall side-circuits at 552kHz no

less than:90% of all combinations100% of all combinations

62dB/42557dB/425m

Protection of far end between allside-circuit at 552kHz no less

than90% of all combinations100% of all combinations

70dB/425m66dB/425m

Test voltage 50Hz, 2 min.wire-wire

wire-sheath1000V2000V

Operating voltage peak value 300V

Temperature rangelaying and installing

exploitation and storage

0oC äî +45oC-30oC äî +50oC

Bending radius, min. approx. 20 õ D cable

Number of quadsNumber of quads in the layers

1 2

3 3

4 4

7 1 6

Cable core construction

Construction data MKBs...x4x1.2

Number of quads Outer diameterapprox. Copper weight Cable weight

approx. s

mm kg/km kg/km

3 27.7 134 1613

4 28.5 179 17417 33.8 313 2341

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad markingIn each layer there is a quad with red supportingspiral from which the counting starts and a quadshowing the direction of counting - with yellow

supporting spiral

Type codesM trunk cableK paper band insulationB steel tape armour

s protective sheath of bitumen and yarn

Page 345: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 345/430

344

H I G H F R E Q U E N C Y

C O M M U N I C A T I O N

S C A B L E S F O R T R

U N K C A B L E N E T W

O R K S

E L KA B E L

MKBP . . . x4x1.2 BDS 5052-90.

Technical data

Color coding

Application

These cables are used for construction of trunk cable communication network and connection lines between automatic telephone

exchanges, with the possibility for using multi-channel systems with a frequency range of up to 552 kHz.

They are suitable for laying in ditches in all types of grounds, where there is less force of strain and inclined terrain less than 45Ó.

The use of these cables for high voltage power installations is not permitted.

Paper band insulation quads stranded in layers lead sheath steel tape armour

protective PE sheath

Construction data MKBP...x4x1.2

Number of quads Outer diameterapprox Copper weight Cable weight

approx.

mm kg/km kg/km

3 27.7 134 16244 28.3 179 18587 34.0 313 2364

Cable construction

Conductor Bare copper conductor diameter 1.2mmInsulation Paper string insulation, over which there

is a paper tapeQuad 4 wires are twisted into a quadCable core Quads are twisted concentrically into

layers Wrapping Several layers of paper tapesSheath of lead, containing antimony of 0.4 to

0.6%Pad Bitumen and impregnated cable paper

Armour Two steel tapesProtective PE low density with 2.5% carbon blacksheath

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad markingIn each layer there is a quad with red supportingspiral from which the counting starts and a quadshowing the direction of counting - with yellow

supporting spiral

Type codesM trunk cableK paper band insulationB steel tape armourP polyethylene protective sheath

Cable core construction

Conductor diameter 1.2mm

Resistance of side circuits at20oC-max 31.7 Ω/km

Ohmic asymmetry - max. 0.13/425m

Insulation resistance - min. 12 000 MΩ.km

Mutual capacitance at 800Hz-nom. 26.5nF/km

Attenuation of near end between

all side-circuits at 552kHz noless than

90% of all combinations100% of all combinations

62dB/42557dB/425m

Protection of far end between all

side-circuit at 552kHz no less

than

90% of all combinations

100% of all combinations70dB/425m66dB/425m

Test voltage 50Hz, 2 min.wire-wire

wire-sheath1000V2000V

Operating voltage peak value 300V

Temperature rangelaying and installing

exploitation and storage-5oC äî +50oC-40oC äî +70oC

Bending radius, min. approx. 20 õ D cable

Number of quadsNumber of quads in the layers

1 2

3 3

4 4

7 1 6

Page 346: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 346/430

345

H I G H F R

E Q U E N C Y C O MM U N I C A T

I O N S C A B L E S F O R T R U N

K C A B L E N E T W O R K S WI T H L O W R E D U C T I O N F A C

T O R

E L KA B E L

Application

These cables are used for construction of trunk cable communication network and connection lines between automatic telephone

exchanges, with the possibility for using multi-channel systems with a frequency range of up to 252 kHz.

They are suitable for laying in ditches, where there is less force of strain and inclined terrain less than 45Ó, in areas with high electro

magnetic influence (fields). The use of these cables for high voltage power installations is not permitted.

MKEmPBP . . . x4x1.2

Technical data

Color coding

Cable core construction

Paper band insulation quads stranded in layers lead sheath screen steel tape

armour protective PE sheath

Construction data MKEmPBP...x4x1.2

Number of quads Outer diameterapprox. Copper weight Cable weight

approx.

mm kg/km kg/km

4 36 765 3006

Cable construction

Conductor Bare copper conductor diameter1.2mm

Insulation Paper string insulation, over whichthere is a paper tape

Quad 4 wires are twisted into a quadCable core Quads are twisted concentrically into

layers Wrapping Several layers of paper tapesSheath of lead, containing antimony of 0.4 to

0.6%Screen Two layers of copper tapesInner sheath PolyethylenePad Bitumen and impregnated cable

paper Armour Two steel tapesProtective PE low density with 2.5% carboncovering black

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad markingIn each layer there is a quad with red supportingspiral from which the counting starts and a quadshowing the direction of counting - with yellow

supporting spiral

Number of quads Number of quads in the layers

4 4

Conductor diameter 1.2mm

Resistance of side circuits at20oC-max 31.7 Ω/km

Ohmic asymmetry - max. 0.13/425m

Insulation resistance - min. 12 000 MΩ.km

Mutual capacitance at 800Hz-nom. 26.5nF/km

Attenuation of near end betweenall side-circuits at 252kHz no

less than:

90% of all combinations100% of all combinations

62dB/42557dB/425m

Protection of far end between allside-circuit at 252kHz no less

than90% of all combinations100% of all combinations

70dB/425m66dB/425m

Test voltage 50Hz, 2 min.wire-wire

wire-sheath1000V2000V

Reduction factor, Inductive volt-age 50 to 400 V and frequency

50Hz, no more than 0.3

Operating voltage peak value 300V

Temperature rangelaying and installing

exploitation and storage-5oC äî +50oC-40oC äî +70oC

Bending radius, min. approx. 20 õ D cable

Type codes

M trunk cableK paper band insulationEm copper tape screenP PE sheathB steel tape armourP Protective PE sheath

BDS 5052-90 andTU "ELKABEL"

Page 347: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 347/430

346

C O M B I N E D C O M M

U N I C A T I O N C A B L E S

W I T H H F A N D L F Q U A D S F O R T R U N K N E T

W O R K S

E L KA B E L

MKKG 4x4x1.2 + 15ı4ı1.2 BDS 5052-90

Cable construction

Conductor Bare copper conductor diameter1.2mm

Insulation Paper string insulation, over whichthere is a paper tape

Quad 4 wires are twisted into a quadCable core Twisted in the middle are 4HF quads

and around them are twisted concentrically 15 LF quads

Wrapping Several layers of paper tapesSheath of lead, containing antimony of 0.4 to

0.6%

Technical data

Color coding

Application

These cables are used for construction of trunk cable communication network and connection lines between automatictelephone exchanges, with the possibility for transferring of HF and LF, and HF quads may be compressed in frequen-cy range up to 252 kHz.These cables are suitable for fixed installations in collectors, cable ducts and pipes.The use of these cables for high voltage power installations is not permitted.

Cable core construction

Paper band insulation quads stranded in layers lead sheath

Construction data MKKG 4x4x1.2+15õ4õ1.2

Cross section Outer diameterapprox. Copper weight Cable weight

approx.

mm kg/km kg/km

4õ4õ1.2+15õ4õ1.2 30.8 789 2613

Type codesM trunk cableK combined

K paper band insulationG no protective sheath

Conductor diameter 1.2mm

Resistance of side circuits at20oC-max 31.7 Ω/km

Ohmic asymmetry of HF quads -max. 0.13/425m

Insulation resistance - min. 12 000 MΩ.km

Mutual capacitance at 800Hz-nom.HF quadsLF quads

26.5nF/km35 nF/km

Attenuation of near end betweenall side-circuits of HF quads at

552kHz no less than90% of all combinations100% of all combinations

62dB/42557dB/425m

Protection of far end between allside-circuits of HF at 552kHz no

less than90% of all combinations100% of all combinations

70dB/425m66dB/425m

Test voltage 50Hz, 2 min.wire-wire

wire-sheath1000V2000V

Operating voltage peak value 300V

Temperature rangelaying and installing

exploitation and storage-5oC äî +50oC

-40oC äî +70oC

Bending radius, min. approx. 20 õ D cable

Cross sectionNumber of quads in the layers

1 2

4x4x1.2+15x4x1.2 4 HF quads 15 LF quads

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad markingIn each layer there is a quad with red supportingspiral from which the counting starts and a quadshowing the direction of counting - with yellow

supporting spiral

Page 348: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 348/430

347

C O MB I N E D C O MM U N I C A T I O N C A B L E S WI T H H F

A N D L F Q U A D S F O R

T R U N K N E T W O R K S

E L KA B E L

Application

These cables are used for construction of trunk cable communication network and connection lines between automatictelephone exchanges, with the possibility for transferring of HF and LF, where HF quads may be compressed in a fre-quency range of up to 252 kHz.They are suitable for laying in ditches in all types of grounds, where there is less force of strain and inclined terrain noless than 45Ó. The use of these cables for high voltage power installations is not permitted.

MKKBs 4x4x1.2 + 15ı4ı1.2BDS 5052-90

Technical data

Color coding

Cable core construction

Paper band insulation quads stranded in layers lead sheath steel tape armour

protective sheath of yarn

Construction data MKKBs 4x4x1.2+15õ4õ1.2

Cross section Outer diameterapprox. Copper weight Cable weight

approx.

mm kg/km kg/km

4õ4õ1.2+15õ4õ1.2 39.3 807 3369

Conductor diameter 1.2mm

Resistance of side circuits at20oC-max 31.7 Ω/km

Ohmic asymmetry of HF quads -max. 0.13/425m

Insulation resistance - min. 12 000 MΩ.km

Mutual capacitance at 800Hz-nom.

HF quads

LF quads

26.5nF/km35 nF/km

Attenuation of near end betweenall side-circuits of HF quads at

552kHz no less than90% of all combinations100% of all combinations

62dB/42557dB/425m

Protection of far end between allside-circuits of HF at 552kHz no

less than90% of all combinations100% of all combinations

70dB/425m66dB/425m

Test voltage 50Hz, 2 min.wire-wire

wire-sheath1000V2000V

Operating voltage peak value 300V

Temperature rangelaying and installing

exploitation and storage0oC äî +45oC

-30oC äî +50oC

Bending radius, min. approx. 20 õ D cable

Type codesM trunk cableK combinedK paper band insulationB steel tape armours protective sheath of bitumen and synthetic yarn

Cross sectionNumber of quads in the layers

1 2

4x4x1.2+15x4x1.24 HF quads 15 LF quads

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad markingIn each layer there is a quad with red supportingspiral from which the counting starts and a quadshowing the direction of counting - with yellow

supporting spiral

Cable construction

Conductor Bare copper conductor diameter1.2mm

Insulation Paper string insulation, over whichthere is a paper tape

Quad 4 wires are twisted into a quadCable core Twisted in the middle are 4HF quads

and around them are twisted concentrically 15 LF quads

Wrapping Several layers of paper tapesSheath of lead, containing antimony of 0.4 to

0.6%Pad Bitumen and impregnated cable

paper Armour Two steel tapesProtective of bitumen, synthetic yarn and chalksheath

Page 349: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 349/430

348 E L KA B E L

MKKBP 4x4x1.2 + 15ı4ı1.2 BDS 5052-90

Cross sectionNumber of quads in the layers

1 2

4x4x1.2+15x4x1.2 4 HF quads 15 LF quads

Cable construction

Conductor Bare copper conductor diameter 1.2mmInsulation Paper string insulation, over which there is a

paper tapeQuad 4 wires are twisted into a quadCable core Twisted in the middle are 4HF quads and

around them are twisted concentrically 15 LFquads

Wrapping Several layers of paper tapesSheath of lead, containing antimony of 0.4 to 0.6%Pad Bitumen and impregnated cable paper

Armour Two steel tapesProtective sheath PE low density with 2.5% carbon black

Technical data

Color coding

Application

These cables are used for construction of trunk cable communication network and connection lines between automatictelephone exchanges, with the possibility for transferring of HF and LF, where HF quads may be compressed in a fre-quency range of up to 252 kHz.They are suitable for laying in ditches in all types of grounds, where there is less force of strain and inclined terrain less

than 45Ó.The use of these cables for high voltage power installations is not permitted.

Cable core construction

Paper band insulation quads stranded in layers lead sheath steel tape armour

protective PE sheath

Type codesM trunk cableK combinedK paper band insulationB steel tape armourP PE protective sheath

Construction dataMKKBP 4x4x1.2+15õ4õ1.2

Cross section Outer diameterapprox. Copper weight Cable weight

approx.

mm kg/km kg/km

4õ4õ1.2+15õ4õ1.2 39.9 807 3654

Conductor diameter 1.2mm

Resistance of side circuits at20oC-max 31.7 Ω/km

Ohmic asymmetry of HF quads -max. 0.13/425m

Insulation resistance - min. 12 000 MΩ.km

Mutual capacitance at 800Hz-nom.

HF quads

LF quads

26.5nF/km35 nF/km

Attenuation of near end betweenall side-circuits of HF quads at

552kHz no less than90% of all combinations100% of all combinations

62dB/42557dB/425m

Protection of far end between allside-circuits of HF at 552kHz no

less than90% of all combinations100% of all combinations

70dB/425m66dB/425m

Test voltage 50Hz, 2 min.wire-wire

wire-sheath1000V2000V

Operating voltage peak value 300V

Temperature range

laying and installing

exploitation and storage

-5oC äî +50oC-40oC äî +70oC

Bending radius, min. approx. 20 õ D cable

C O M B I N E D C O M M U N I C A T I O N C A B L E S

W I T H H F A N D L F Q U

A D S F O R T R U N K N E T W O R K S

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad marking

In each layer there is a quad with red supportingspiral from which the counting starts and a quadshowing the direction of counting - with yellow

supporting spiral

Page 350: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 350/430

349

C O MB I

N E D C O MM U N I C A T I O N

C A B L E S WI T H H F A N D

L F Q U A D S A N D L O W

R

E D U C T I O N F A C T O R

E L KA B E L

MKKEmPBP 4x4x1.2 + 15ı4ı1.2BDS 5052-90 andTU"ELKABEL".

Cross sectionNumber of quads in the layers

1 24x4x1.2+15x4x1.2 4 HF quads 15 LF quads

Cable construction

Conductor Bare copper conductor diameter1.2mm

Insulation Paper string insulation, overwhich there is a paper tape

Quad 4 wires are twisted into a quadCable core Twisted in the middle are 4HF

quads and around them are twisted concentrically 15 LF quads

Wrapping Several layers of paper tapesSheath of lead, containing antimony of

0.4 to 0.6%Screen Two layers of copper tapesInner sheath PEPad Bitumen and impregnated cable

paper Armour Two steel tapesProtective PE low density with 2.5% carbonsheath black

Technical data

Color coding

Application

These cables are used for construction of trunk cable communication network and connection lines between automatictelephone exchanges, with the possibility for transferring of HF and LF, where HF quads may be compressed in a fre-quency range of up to 552 kHz.They are suitable for laying in ditches in all types of grounds, where there is less force of strain and inclined terrain less

than 45Ó, in areas with high electro-magnetic influence.The use of these cables for high voltage power installations is not permitted.

Cable core construction

Paper band insulation quads stranded in layers lead sheath screen steel tape armor

protective PE sheath

Construction data MKKEmPBP 4x4x1.2+15õ4õ1.2

Cross section Outer diameterapprox. Copper weight Cable weight

approx.

mm kg/km kg/km4õ4õ1.2+15õ4õ1.2 47.5 1571 5059

Conductor diameter 1.2mm

Resistance of side circuits at20oC-max 31.7 Ω/km

Ohmic asymmetry of HF quads -max. 0.13/425m

Insulation resistance - min. 12 000 MΩ.km

Mutual capacitance at 800Hz-nom.

HF quadsLF quads

26.5nF/km35 nF/km

Attenuation of near end betweenall side-circuits íà HF quads at

552kHz no less than90% of all combinations100% of all combinations

62dB/42557dB/425m

Protection of far end between allside-circuits of HF at 552kHz no

less than90% of all combinations100% of all combinations

70dB/425m66dB/425m

Reduction factor, Inductive volt-age 50 to 400 V and frequency

50Hz, no more than0.3

Test voltage 50Hz, 2 min.wire-wire

wire-sheath1000V2000V

Operating voltage peak value 300V

Temperature rangelaying and installing

exploitation and storage

-5oC äî +50oC-40oC äî +70oC

Bending radius, min. approx. 20 õ D cable

Type codesM trunk cableK combinedK paper band insulationEm copper tape screenP PE sheathB steel tape armorP protective PE sheath

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad markingIn each layer there is a quad with red supportingspiral from which the counting starts and a quadshowing the direction of counting - with yellow

supporting spiral

Page 351: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 351/430

350

C O M B I N E D C O M M U N I C A T I O N C A B L E S W I T H H F A N D L F Q U A D S A N D L O W R

E D U C T I O N

F A C T O R F O R R A I L W A Y T R

A N S P O R T

E L KA B E L

MKKEmPBPj 4x4x1.2 + 15ı4ı1.2 BDS 5052-90 andTU "ELKABEL".

Cross sectionNumber of quads in the layers

1 2

4x4x1.2+15x4x1.2 4 HF quads 15 LF quads

Cable constructionConductor Bare copper conductor diameter

1.2mmInsulation Paper string insulation, over which

there is a paper tapeQuad 4 wires are twisted into a quadCable core Twisted in the middle are 4HF quads

and around them are twisted concentrically 15 LF quads

Wrapping Several layers of paper tapesSheath of lead, containing antimony of 0.4 to

0.6%Screen Two layers of copper tapes

Inner sheath PEPad Bitumen and impregnated cable paper Armour Two steel tapesProtective PE low density with 2.5% carbon blacksheath

Technical data

Color coding

Application

These cables are used for construction of trunk cable communication network, which are close to electrical railwaylines, with the possibility for transferring HF and LF signals, and HF quads may be compressed in frequency range upto 252 kHz.They are suitable for laying in ditches in all types of grounds, where there is less force of strain and inclined terrain less

than 45Ó, in areas with high electro-magnetic influence (fields).The use of these cables for high voltage power installations is not permitted.

Cable core construction

Paper band insulation quads stranded in layers lead sheath steel tape armour protective PE sheath

Construction data MKKEmPBPj 4x4x1.2+15õ4õ1.2

Cross section Outer diameterapprox. Copper weight Cable weight

approx.

mm kg/km kg/km

4õ4õ1.2+15õ4õ1.2 51.4 1644 5776

Type codesM trunk cable; K combined ;K paper band insulationEm copper tape screen; P PE sheath; B steel tape armourP PE protective sheath; j for railway transport

Conductor diameter 1.2mm

Resistance of side circuits at20oC-max 31.7 Ω/km

Ohmic asymmetry of HF quads -max. 0.13/425m

Insulation resistance - min. 12 000 MΩ.km

Mutual capacitance at 800Hz-nom.

HF quadsLF quads

26.5nF/km35 nF/km

Attenuation of near end betweenall side-circuits of HF quads at

252kHz no less than90% of all combinations

100% of all combinations62dB/425

57dB/425m

Protection of far end between allside-circuits of HF at 252kHz no

less than90% of all combinations

100% of all combinations70dB/425m66dB/425m

Reduction factor,Inductive voltage 50 to 400 V and

frequency 50Hz, no more than 0.1

Test voltage 50Hz, 2 min.wire-wire

wire-sheathsheath - screen

1000V2000V8600

Operating voltage peak value 300V

Temperature rangelaying and installing

exploitation and storage-5oC äî +50oC-40oC äî +70oC

Bending radius, min. approx. 20 õ D cable

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad markingIn each layer there is a quad with red supportingspiral from which the counting starts and a quadshowing the direction of counting - with yellow

supporting spiral

Page 352: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 352/430

Page 353: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 353/430

C O M M U N I C A T

I O N C A B L E S F O

R L O N G D I S T A

N C E S

Type codesT telephone cableZ twisted into star quadG no protective sheath

Cable construction

Conductor Bare copper conductor diameter0.9 mm and 1.2mm

Insulation Paper string insulation, over whichthere is a paper tape

Quad 4 wires are twisted into a quadCable core Quads are twisted concentrically intolayers

Wrapping Several layers of paper tapesSheath of lead, containing antimony of 0.4 to

0.6%

Technical data

Color coding

352

Application

These cables are used for construction of inter city cable communication networks and connection lines between auto-matic telephone exchanges, where there is transfer of low frequency signals.These cables are suitable for fixed installations in collectors, cable ducts and pipes.The use of these cables for high voltage installations and for direct laying underground is not permitted.

Conductor diameter 0.9 1.2mm

Conductor resistance at 20∞C-max 28.3 15.85Ω/km

Insulation resistance - min. 12 000 MΩ.km

Mutual capacitance at 800Hz-nom. 34 35nF/km

Capacity unbalances at 800Hz:K1 - max.K2-3- max.

K9-12- max.E1-2 - max.

280 pF/425m700 pF/425m210 pF/425m700 pF/425m

Test voltage 50Hz, 2 min. wire-wire

wire-sheath

700 1000V

2000VOperating voltage peak value 225V

Temperature rangelaying and installing

exploitation and storage-20∞ C ‰Ó +50∞ C-30∞ C ‰Ó +70∞ C

Bending radius, min. approx. 20 ı D cableSide circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad marking

In each layer there is a quad with red supportingspiral from which the counting starts and a quadshowing the direction of counting - with yellow

supporting spiral

E L KA B E L

TZG . . . x4x0.9TZG . . . x4x1.2

BDS 5052-90.

Page 354: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 354/430

Construction data TZG...x4x1.2

Number ofquads

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

34

7

12

14

19

24

27

30

37

44

52

61

75

80

102

114

13.214.2

18.0

23.1

24.3

27.4

31.3

32.5

33.8

37.3

42.0

43.6

46.9

52.3

55.7

62.5

66.1

133177

310

531

620

841

1063

1196

1329

1639

1983

2343

2749

3379

3605

4596

5137

695787

1165

1739

1896

2361

2961

3172

3473

4105

5058

5835

6469

7948

8288

10311

11160

353

C O M

M U N I C A T I O N C

A B L E S F O R L O

N G D I S T A N C E S

E L KA B E L

Construction data TZG...x4x0.9

Number ofquads

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Cable core construction

Number of quadsNumber of quads in the layers

1 2 3 4 5 6

3 3

4 4

7 1 6

12 3 9

14 4 10

19 1 6 12

24 2 8 14

27 3 9 15

30 4 10 16

37 1 6 12 18

44 2 8 14 20

52 4 10 16 22

61 1 6 12 18 2475 3 9 15 21 27

80 4 10 16 22 28

102 2 8 14 20 26 32

114 4 10 16 22 28 34

10.912.0

15.0

18.8

19.8

22.4

25.4

26.8

28.0

30.4

33.8

36.5

39.1

43.4

44.7

50.0

53.3

34

7

12

14

19

24

27

30

37

44

52

61

75

80

102

114

547596

829

1207

1311

1616

1961

2182

2330

2666

3387

3772

4389

5163

5373

6719

7299

75100

175

300

50

474

599

674

749

924

1118

1321

1550

1905

2032

2591

2896

Paper band insulation quads stranded in layers lead sheath

Page 355: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 355/430

Cable construction

Conductor Bare copper conductor diameter0.9 mm and 1.2mm

Insulation Paper string insulation, over whichthere is a paper tape

Quad 4 wires are twisted into a quadCable core Quads are twisted concentrically intolayers

Wrapping Several layers of paper tapesSheath of lead, containing antimony of 0.4 to

0.6%Pad Bitumen and impregnated cable

paper Armour Two steel tapesProtective of bitumen, synthetic yarn and chalksheath

Technical data

Color coding

Conductor diameter 0.9 1.2mm

Conductor resistance at20∞C-max

28.3 15.85Ω/km

Insulation resistance -min.

12 000 MΩ.km

Mutual capacitance at800Hz-nom.

34 35nF/km

Capacity unbalances at800Hz:

K1 - max.K2-3- max.

K9-12- max..E1-2 - max.

280 pF/425m700 pF/425m210 pF/425m700 pF/425m

Test voltage 50Hz, 2 min.wire-wire

wire-sheath

700 1000V

2000V

Operating voltage peak

value225V

Temperature rangelaying and installing

exploitation and storage0∞C ‰Ó +45∞C

-30∞C ‰Ó +50∞C

Bending radius, min.approx.

20 ı D cable

354

Application

These cables are used for construction of inter city cable communication networks and connection lines between auto-matic telephone exchanges, where there is transfer of low frequency signals.They are suitable for laying in ditches, where there is less force of strain and inclined terrain less than 45Ó.The use of these cables for high voltage power installations is not permitted.

C O M M U N I C A T

I O N C A B L E S F O

R L O N G D I S T A

N C E S

E L KA B E L

TZBs . . .x4x0.9

TZBs . . .x4x1.2

BDS 5052-90

Type codesT telephone cableZ twisted into star quadB steel tape armours protective sheath of bitumen and synthetic yarn

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad marking

In each layer there is a quad with red supportingspiral from which the counting starts and a quadshowing the direction of counting - with yellow

supporting spiral

Page 356: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 356/430

355

C O M

M U N I C A T I O N C

A B L E S F O R L O

N G D I S T A N C E S

E L KA B E L

Cable core construction

Number of quadsNumber of quads in the layers

1 2 3 4 5 6

Construction data TZBs...x4x0.9

Number ofquads

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Construction data TZBs...x4x1.2

Number ofquads

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

3 19.1 76 812

4 20.2 102 909

7 23.2 178 1188

12 27.7 306 1760

14 28.7 357 1888

19 31.1 484 2232

24 34.1 612 2617

27 35.5 688 2828

30 36.7 765 3002

37 38.9 943 3405

44 42.4 1121 4020

52 45.0 1325 4528

61 47.6 1555 5074

75 51.8 1911 5908

80 53.0 2039 6286

102 58.5 2600 7695

114 63.0 2905 9121

3 21.4 136 1019

4 22.4 181 1132

7 26.9 317 169812 31.8 544 2345

14 33.0 634 2528

19 36.1 861 3019

24 39.9 1087 3650

27 41.1 1223 3883

30 42.4 1359 4195

37 45.8 1676 4876

44 50.4 1993 5783

52 52.0 2356 6294

61 55.4 2763 7298

75 62.0 3398 9378

80 65.3 3624 10161

102 72.1 4621 12346

114 75.7 5165 13746

3 3

4 4

7 1 6

12 3 9

14 4 10

19 1 6 12

24 2 8 14

27 3 9 15

30 4 10 16

37 1 6 12 18

44 2 8 14 20

52 4 10 16 22

61 1 6 12 18 24

75 3 9 15 21 2780 4 10 16 22 28

102 2 8 14 20 26 32

114 4 10 16 22 28 34

Paper band insulation quads stranded in layers lead sheath steel tape armour protective sheath of yarn

Page 357: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 357/430

Technical data

Color coding

356

Application

These cables are used for construction of inter city cable communication networks and connection lines between auto-matic telephone exchanges, where there is transfer of low frequency signals.They are suitable for laying in ditches in all types of grounds, where there is less force of strain and inclined terrain lessthan 45Ó.The use of these cables for high voltage power installations is not permitted.

C O M M U N I C A T

I O N C A B L E S F O

R L O N G D I S T A

N C E S

E L KA B E L

TZBP . . . x4x0.9

TZBP . . . x4x1.2

BDS 5052-90

'Conductor diameter 0.9 1.2mm

Conductor resistance at20∞C-max 28.3 15.85Ω/km

Insulation resistance -min. 12 000 MΩ.km

Mutual capacitance at800Hz-nom. 34 35nF/km

Capacity unbalances at800Hz:

K1 -max.K2-3- max.

K9-12- max.E1-2 - max.

280 pF/425m700 pF/425m210 pF/425m700 pF/425m

Test voltage 50Hz, 2 min.wire-wire

wire-sheath

700 1000V

2000V

Operating voltage peak value 225V

Temperature rangelaying and installingÔËexploitation and storage

0∞C ‰Ó +45∞C-30∞C ‰Ó +50∞C

Bending radius, min.approx. 20 ı D cable

Cable construction

Conductor Bare copper conductor diameter0.9 mm and 1.2mm

Insulation Paper string insulation, over whichthere is a paper tape

Quad 4 wires are twisted into a quadCable core Quads are twisted into layers

Wrapping Paper tapesSheath of lead, containing antimony of 0.4 to

0.6%Pad Bitumen and impregnated cable

paper Armour Two steel tapesProtective PE low density with 2.5% carbonsheath black

Type codesT telephone cableZ twisted into star quadB steel tape armour

P protective PE sheath

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad marking

In each layer there is a quad with red supporting

spiral from which the counting starts and a quad

showing the direction of counting - with yellow

supporting spiral

Page 358: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 358/430

357

C O M

M U N I C A T I O N C

A B L E S F O R L O

N G D I S T A N C E S

E L KA B E L

Cable core construction

Number of quadsNumber of quads in the layers

1 2 3 4 5 6

Construction data TZBP...x4x0.9

Number ofquads

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Construction data TZBP...x4x1.2

Number ofquads

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Paper band insulation quads stranded in layers lead sheath steel tape armour protective PE sheath

3 3

4 4

7 1 6

12 3 9

14 4 10

19 1 6 12

24 2 8 14

27 3 9 15

30 4 10 16

37 1 6 12 18

44 2 8 14 20

52 4 10 16 22

61 1 6 12 18 24

75 3 9 15 21 27

80 4 10 16 22 28102 2 8 14 20 26 32

114 4 10 16 22 28 34

3 18.7 76 798

4 19.7 102 891

7 22.8 178 1179

12 27.6 306 1737

14 28.6 357 1869

19 31.0 484 2204

24 34.3 612 2598

27 35.5 688 2790

30 36.9 765 2966

37 39.5 943 3393

44 42.9 1121 3879

52 45.9 1325 4479

61 48.7 1555 5019

75 53.1 1911 5891

80 54.4 2039 6215

102 59.7 2600 7438

114 64.9 2905 9081

3 20.9 136 998

4 22.0 181 1107

7 26.7 317 1683

12 32.0 544 2327

14 33.2 634 2508

19 36.0 861 2970

24 40.5 1087 3631

27 41.8 1223 3883

30 43.1 1359 4182

37 46.5 1676 4851

44 51.7 1993 6219

52 53.3 2356 6253

61 56.9 2763 7083

75 63.8 3398 9173

80 67.4 3624 10137

102 74.4 4621 12321

114 78.2 5165 13755

Page 359: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 359/430

Cable construction

Conductor Bare copper conductor diameter0.9 mm and 1.2mm

Insulation Paper string insulation, over whichthere is a paper tape

Quad 4 wires are twisted into a quadCable core Quads are twisted into layers

Wrapping Paper tapesSheath of lead, containing antimony of 0.4

to 0.6%Screen Two layers of copper tapesInner sheath PEPad Bitumen and impregnated cable

paper Armour Two steel tapesProtective PE low density with 2.5% carbonsheath black

Technical data

358

Application

These cables are used for construction of inter city cable communication networks and connection lines between auto-matic telephone exchanges, where there is transfer of low frequency signals.They are suitable for laying in ditches, where there is less force of strain and inclined terrain less than 45Ó, in areas withhigher electro magnetic fields.The use of these cables for high voltage power installations is not permitted.

C O M M U N I C A T I O N C A B L E S F O R L O N G

D I S T A N C E S W I T H

L O W R

E D U C T I O N F

A C T O R

E L KA B E L

TZEmPBP ... x4x0.9

TZEmPBP ... x4x1.2

BDS 5052-90 and TU"ELKABEL"

Conductor diameter 0.9 1.2mm

Conductor resistance at20∞C-max 28.3 15.85Ω/km

Insulation resistance -min. 12 000 MΩ.km

Mutual capacitance at

800Hz-nom.34 35nF/km

Capacity unbalances at800Hz:

K1 - maxK2-3- max

K9-12- maxE1-2 - max

280 pF/425m700 pF/425m210 pF/425m700 pF/425m

Test voltage 50Hz, 2 min.wire-wire

wire-sheath700 1000V

2000V

Operating voltage peak value 225V

Reduction factor,Inductive voltage 50 to 350 V

and frequency 50Hz, nomore than

0.3

Temperature rangelaying and installing

exploitation and storage5∞C ‰Ó +50∞C

-40∞C ‰Ó +70∞C

Bending radius, min.approx. 20 ı D cableColor coding

Type codesT telephone cableZ twisted into star quad≈Ï copper tape screenP protective PE sheathB steel tape armour

P protective PE sheath

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad marking

In each layer there is a quad with red supporting

spiral from which the counting starts and a quad

showing the direction of counting - with yellow

supporting spiral

Page 360: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 360/430

359

C O MM

U N I C A T I O N C A B L E S F O R L O N G D I S T

A N C E S WI T H L O W R E D U C T I O N F A C T O

R

E L KA B E L

Construction data TZEmPBP...x4x0.9

Number of quadsNumber and

thickness of cop-per tapes

Number and thick-ness of steel tapes

Outer diameterapprox.

Copper weightCable weight

approx.

N ı mm N ı mm mm kg/km kg/km

7 2x0.2 2x0.5 28.1 392 1824

14 2x0.3 2x0.8 34.9 778 3027

24 2x0.3 2x0.8 40.2 1150 3928

30 2x0.3 2x0.8 43.4 1360 4503

37 2x0.3 2x0.8 47.0 1592 5040

Construction data TZEmPBP...x4x1.2

Number of quadsNumber and

thickness of cop-per tapes

Number and thick-ness of steel tapes

Outer diameterapprox.

Copper weightCable weight

approx.

N ı mm N ı mm mm kg/km kg/km

3 2x0.2 2x0.5 26.3 327 1550

4 2x0.2 2x0.5 27.5 386 1692

7 2x0.3 2x0.8 33.5 708 2722

12 2x0.3 2x0.8 39.1 1041 3604

14 2x0.3 2x0.8 40.4 1157 3844

19 2x0.3 2x0.8 43.3 1439 4446

24 2x0.3 2x0.8 48.0 1755 5297

27 2x0.3 2x0.8 49.5 1918 5598

30 2x0.3 2x0.8 50.9 2082 5976

37 2x0.3 2x0.8 54.5 2467 6815

Paper band insulation quads stranded in layers lead sheath screen steeltape armour protective PE sheath

Cable core construction

Number of quads

Number of quads in the layers

1 2 3 4

3

4

7

12

14

19

24

27

30

37

3

4

1

3

4

1

2

3

4

1

6

9

10

6

8

9

10

6

12

14

15

16

12 18

Page 361: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 361/430

Cable construction

Conductor Bare copper conductor diameter0.9 mm .

Insulation Paper string insulation, over whichthere is a paper tape

Quad 4 wires are twisted into a quadCable core Quads are twisted into layers

Wrapping Paper tapesSheath of lead, containing antimony of 0.4 to

0.6%Screen Two layers of copper tapesInner sheath PEPad Bitumen and impregnated cable

paper Armour Two steel tapesProtective PE low density with 2.5% carbonsheath black

Technical data

360

Application

These cables are used for construction of inter city cable communication networks and connection lines between auto-matic telephone exchanges, where there is transfer of low frequency signals.They are suitable for laying in ditches, where there is less force of strain and inclined terrain less than 45Ó, in areas withhigher electro magnetic fields.The cables are higher electric strength with low reduction factor for energetics.

C O M M U N I C A T I O N C A

B L E S F O R L O N G D I S T A

N C E S W I T H L O W R

E D U C

T I O N F A C T O R F O R E N E

R G E T I C S

E L KA B E L

TZEmPBPe ... x4x0.9 BDS 5052-90 and TU"ELKABEL"

Conductor diameter 0.9 mm

Conductor resistance at20∞C-max 28.3 Ω/km

Insulation resistance -min. 12 000 MΩ.km

Mutual capacitance at800Hz-nom. 34 nF/km

Capacity unbalances at800Hz:

K1 - max.K2-3- max.

K9-12- max.E1-2 - max.

280 pF/425m700 pF/425m210 pF/425m700 pF/425m

Test voltage 50Hz, 2 min.wire-wire

wire-sheath700

4000V

Operating voltage peak value 225V

Reduction factor, Inductivevoltage 30 to 500 V and fre-quency 50Hz, no more than: 0.3 up to 14ı4ı0.9

0.1 over 19ı4ı0.9

Temperature rangelaying and installing

exploitation and storage5∞C ‰Ó +50∞C

-40∞C ‰Ó +70∞C

Bending radius, min.approx. 20 ı D cable

Type codesT telephone cableZ twisted into star quad≈Ï copper tape screenP protective PE sheathB steel tape armour

P protective PE sheath for energetics

Color coding

Side circuit - 1 Side circuit - 2

à- wire b- wire à- wire b- wire

white red green blue

Quad marking

In each layer there is a quad with red supporting

spiral from which the counting starts and a quad

showing the direction of counting - with yellow

supporting spiral

Page 362: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 362/430

361

C O MM U

N I C A T I O N C A B L E S F O R

L O N G D I S T A N C E S WI T H L O W R E D U C T I O N F A C

T O R F O R E N E R G E T I C S

E L KA B E L

Cable core construction

Number of quads

Number of quads in the layers

1 2 3 4

3

4

7

12

14

19

24

27

30

37

3

4

1

3

4

1

2

3

4

1

6

9

10

6

8

9

10

6

12

14

15

16

12 18

Construction data TZEmPBPe...x4x0.9

Number ofquads

Outer diameterapprox.

Cable weightapprox.

mm kg/km

3

4

7

12

14

19

24

2730

25.2

26.3

30.8

35.8

37.0

39.4

43.5

44.545.7

1537

1663

2474

3205

3385

3825

4498

46984911

Paper band insulation quads stranded in layers lead sheath screen steeltape armour protective PE sheath

Page 363: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 363/430

Cable construction

Conductor Bare copper conductor diameter0.4 mm , 0.5mm, 0.6mm, 0.7mm

Insulation PE low densityQuad 4 wires are twisted into a quadUnits 5 quads are twisted to a basic unit

Unit marking In each layer there is a unit with redsupporting spiral form at which thecounting starts and a unit showingthe direction of counting - with yellowsupporting spiral.

Cable core The units are stranded into a cable Wrapping Several layers of plastic tapesScreen aluminum tape, thickness no less

than 0.04mm, one side coated withcopolymer and 1 tinned copper wirewith diameter of 0.5mm under thealuminum foil

Sheath PE low density with 2.5% carbonblack

Technical data

Color coding

Application

These cables are used as connecting cables in local networks and PABX's for telephone purposes and for transmis-sion of signals.They are suitable for underground installations, in cable ducts and conduit, as well as for interior installations.The use of these cables for power installations is not permitted.These cables may only be used in locations with fire and explosion hazards in accordance with the appropriate safetyprecautions.

C

O M M U N I C A T I O

N C A B L E S F O R

L O C A L N E T W O R K S

E L KA B E L

TPP . . . x2x0.4; TPP . . . x2x0.6

TPP . . . x2x0.5; TPP . . . x2x0.7

BDS 9096-83

362

Type codesT telephone cableP polyethylene insulationP polyethylene sheath

Conductor diameter 0.4 0.5mm

Conductor resistance at 20∞C-max 150 95Ω/km

Conductor diameter 0.6 0.7mm

Conductor resistance at 20∞C-max. 65 49Ω/km

Insulation resistance - min. 10GΩ

.kmMutual capacitance at 800Hz-nom. 48nF/km

Capacity unbalances at 800Hz:K1 100% of all values

95% of all valuesK9-K12 100% of all values

90% of all values

980pF/500m420pF/500m800pF/500m

200pF/mTest voltage 50Hz, 2 min.

wire-wirewire-screen

500V2000V

Operating voltage peak value

Cables with cores 0.4 and 0.5mmCables with cores 0.6 and 0.7mm

150V220V

Temperature rangelaying and installing

exploitation and storage-10∞C ‰Ó +60∞C-50∞C ‰Ó +60∞C

Bending radius, min. approx. 10 x cablediameter

Number ofquad

Side-circuit -1 Side-circuit -2

a-wire b-wire a-wire b-wire

1 white red green blue

2 yellow red green blue

3 gray red green blue

4 brown red green blue

5 black red green blue

Page 364: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 364/430

363

C O M

M U N I C A T I O N C

A B L E S F O R L O

C A L N E T W O R K

S

Polyethylene insulation unit stranding laminated sheath

E L KA B E L

Cable core construction

Number ofpairs

Number ofquads

Number of units

5ı4 25ı4 50x4

1-st layer 2-nd layer 1-st layer 2-nd layer 1-st layer 2-nd layer

Construction data TPP...

Number ofpairs

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

Construction data TPP...

Number ofpairs

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0.4

6 7.4 17 5110 8.5 27 7320 10.7 51 11730 12.4 74 157

50 15.3 127 24970 17.4 174 324

100 20.5 250 452150 24.7 374 642200 26.5 494 811250 30.4 613 1002300 31.7 738 1177400 37.1 983 1524500 40.4 1235 1902600 44.4 1476 2252700 47.6 1722 2621800 51.0 1968 2993

1000 56.6 2454 37031200 61.8 2941 4413

x2x0.5

6 8.7 26 7110 9.6 40 9720 11.7 78 15130 13.9 115 21550 16.9 196 33270 19.1 269 449

100 22.5 387 613150 27.0 580 880200 29.9 766 1141250 33.7 952 1389300 36.9 1146 1640400 40.4 1526 2161500 45.6 1918 2718600 49.3 2292 3197700 52.2 2674 3720800 64.0 3056 4247

1000 65.0 3813 52581200 69.1 4570 6271

x2x0.6

6 9.3 36 8610 10.5 57 12020 13.2 111 21230 15.4 164 291

50 20.1 281 46970 22.5 387 619

100 26.7 557 852150 32.9 834 1252200 35.9 1102 1601250 40.5 1371 1980300 43.9 1650 2342400 50.1 2197 3094500 54.7 2761 3913600 60.6 3300 4607700 64.7 3851 5357800 69.2 4401 6111

1000 76.8 5491 7565x2x0.7

6 10.1 48 10710 11.8 77 15220 16.1 150 27730 18.7 222 39050 22.7 381 61470 25.6 526 816

100 31.7 757 1150150 38.1 1134 1665200 42.0 1500 2165250 47.1 1865 2676300 51.3 2245 3222400 52.7 2990 4239500 66.0 3757 5286600 71.9 4491 6274700 76.3 5240 7297

6 3 3-quads10 5 120 10 230 15 350 25 570 35 1 6

100 50 3 7150 75 3200 100 4250 125 5300 150 1 5400 200 4500 250 5600 300 1 5700 350 1 6

800 400 1 71000 500 3 71200 600 4 8

Page 365: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 365/430

Cable construction

Conductor Bare copper conductor diameter0.4 mm , 0.5mm, 0.6mm, 0.7mm

Insulation PE low densityQuad 4 wires are twisted into a quadUnits 5 quads are twisted to a basic unit

Unit marking In each layer there is a unit with redsupporting spiral form at which theCounting starts and a unit showingthe direction of counting - with yellowsupporting spiral.

Cable core The units are stranded into a cable Wrapping Several layers of plastic tapesScreen aluminum tape, thickness no less

than 0.04mm, one side coated withcopolymer and 1 tinned copper wirewith diameter of 0.5mm under thealuminum foil

Sheath PE low density with 2.5% carbonblack

Protective PE low density with 2.5% carbon

sheath black

Technical data

Type codesT telephone cableP polyethylene insulationP polyethylene sheath

P polyethylene protective sheath

C

O M M U N I C A T I O

N C A B L E S F O R

L O C A L N E T W O R K S

E L KA B E L

TPPP . . . x2x0.4; TPPP . . .ı2ı0.6

TPPP . . . x2x0.5; TPPP . . .ı2ı0.7

BDS 9096-83

364

Color coding

Application

These cables are used as connecting cables in local networks and PABX's for telephone purposes and for transmis-sion of signals.They are suitable for installations in cable ducts.The use of these cables for power installations is not permitted.These cables may only be used in locations with fire and explosion hazards in accordance with the appropriate safetyprecautions.

Conductor diameter 0.4 0.5mm

Conductor resistance at 20∞C-max 150 95Ω/km

Conductor diameter 0.6 0.7mm

Conductor resistance at 20∞C-max. 65 49Ω/km

Insulation resistance - min. 10GΩ.kmMutual capacitance at 800Hz-nom. 48nF/km

Capacity unbalances at 800Hz:K1 100% of all values

95% of all valuesK9-K12 100% of all values

90% of all values

980pF/500m420pF/500m800pF/500m

200pF/mTest voltage 50Hz, 2 min.

wire-wirewire-screen

500V2000V

Operating voltage peak value

Cables with cores 0.4 and 0.5mmCables with cores 0.6 and 0.7mm

150V220V

Temperature rangelaying and installing

exploitation and storage-10∞C ‰Ó +60∞C-50∞C ‰Ó +60∞C

Bending radius, min. approx. 10 x cablediameter

Number ofquad

Side-circuit -1 Side-circuit -2

a-wire b-wire a-wire b-wire

1 white red green blue

2 yellow red green blue

3 gray red green blue

4 brown red green blue

5 black red green blue

Page 366: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 366/430

365

C O M

M U N I C A T I O N C

A B L E S F O R L O

C A L N E T W O R K

S

PE insulation unit stranding laminated sheath PE protective sheath

E L KA B E L

Cable core construction

Number ofpairs

Number ofquads

Number of units

5ı4 25ı4 50x4

1-st layer 2-nd layer 1-st layer 2-nd layer 1-st layer 2-nd layer

6 3 3-quads10 5 120 10 230 15 350 25 570 35 1 6

100 50 3 7150 75 3200 100 4250 125 5300 150 1 5400 200 4500 250 5600 300 1 5700 350 1 6

800 400 1 71000 500 3 71200 600 4 8

Construction data TPPP

Number ofpairs

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0.4

6 10.2 17 7910 11.3 27 10820 13.5 51 15530 15.1 74 200

50 18.3 127 28870 20.2 174 370

100 23.1 250 499150 26.5 374 718200 29.0 494 884250 33.4 613 1100300 34.7 738 1268400 40.3 983 1652500 45.2 1235 2035600 48.1 1476 2405700 51.6 1722 2767800 55.0 1968 3127

1000 61.1 2454 39321200 66.5 2941 4671

x2x0.5

6 11.2 26 10510 12.2 40 133

20 13.9 78 19030 15.6 115 25050 18.8 196 37370 21.8 269 498

100 24.1 387 669150 28.6 580 951200 32.0 766 1225250 36.3 952 1506300 37.8 1146 1774400 43.3 1526 2292500 48.8 1918 2866600 52.7 2292 3377700 55.1 2674 3884800 59.3 3056 4416

1000 68.6 3813 55531200 73.5 4570 6587

Construction data TPPP

Number ofpairs

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0.6

6 11.9 36 12010 13.0 57 15720 15.7 111 24730 17.8 164 335

50 22.1 281 51270 24.9 387 669

100 28.2 557 920150 35.7 834 1363200 38.9 1102 1730250 43.7 1371 2135300 47.0 1650 2511400 53.6 2197 3300500 58.3 2761 4081600 64.8 3300 4888700 68.9 3851 5647800 73.6 4401 6446

x2x0.7

6 12.6 48 14510 14.3 77 19420 18.5 150 32630 21.1 222 438

50 25.1 381 66370 28.0 526 867100 34.3 757 1250150 41.0 1134 1811200 45.0 1500 2325250 50.4 1865 2873300 55.7 2245 3429400 62.3 2990 4450500 70.3 3757 5599600 76.5 4491 6663700 81.1 5240 7699

Page 367: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 367/430

Technical data

Color coding

Type codesT telephone cableP polyethylene insulationP polyethylene sheath

V protective sheath of polyvinylchloride

C

O M M U N I C A T I O

N C A B L E S F O R

L O C A L N E T W O R K S

E L KA B E L

TPPV . . . x2x0.4; TPPV . . .ı2ı0.6

TPPV . . . x2x0.5; TPPV . . .ı2ı0.7

BDS 9096-83

366

Application

These cables are used as connecting cables in local networks and PABX's for telephone purposes and for transmis-sion of signals.They are suitable for laying in collectors, with higher mechanical load.The use of these cables for power installations is not permitted.

Cable construction

Conductor Bare copper conductor diameter0.4 mm , 0.5mm, 0.6mm, 0.7mm

nsulation PE low densityQuad 4 wires are twisted into a quadUnits 5 quads are twisted to a basic unit

Unit marking In each layer there is a unit with redsupporting spiral form at which thecounting starts and a unit showingthe direction of counting - with yellowsupporting spiral.

Cable core The units are stranded into a cable Wrapping Several layers of plastic tapesScreen aluminum tape, thickness no less

than 0.04mm, one side coated withcopolymer and 1 tinned copper wirewith diameter of 0.5mm under thealuminum foil

Sheath PE low density with 2.5% carbonblack

Protective PVC plastic - color gray

sheath

Conductor diameter 0.4 0.5mm

Conductor resistance at 20∞C-max 150 95Ω/km

Conductor diameter 0.6 0.7mm

Conductor resistance at 20∞C-max. 65 49Ω/km

Mutual capacitance at 800Hz-nom. 48nF/kmCapacity unbalances at 800Hz:

K1 100% of all values95% of all values

K9-K12 100% of all values90% of all values

980pF/500m420pF/500m800pF/500m

200pF/m

Test voltage 50Hz, 2 min.wire-wire

wire-screen500V2000V

Operating voltage peak value

cables with cores 0.4 and 0.5mmcables with cores 0.6 and 0.7mm

150V220V

Temperature rangelaying and installingexploitation and storage

+4∞C ‰Ó +60∞C-30∞C ‰Ó +60∞C

Bending radius, min. approx. 10 x cablediameter

Number ofquad

Side-circuit -1 Side-circuit -2

a-wire b-wire a-wire b-wire

1 white red green blue

2 yellow red green blue

3 gray red green blue

4 brown red green blue

5 black red green blue

Page 368: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 368/430

367

C O M

M U N I C A T I O N C

A B L E S F O R L O

C A L N E T W O R K

S

olyethylene insulation unit stranding laminated sheath polyvinylchloride protectivesheath

E L KA B E L

Cable core construction

Number ofpairs

Number ofquads

Number of units

5ı4 25ı4 50x4

1-st layer 2-nd layer 1-st layer 2-nd layer 1-st layer 2-nd layer

Construction data TPPV...

Number ofpairs

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0.4

6 10.1 17 9910 11.8 27 13220 13.5 51 18230 15.1 74 232

50 18.3 127 32570 20.2 174 413

100 23.1 250 547150 26.5 374 779200 29.0 494 948250 33.4 613 1176300 34.7 738 1349400 40.3 983 1757500 45.2 1235 2156600 48.1 1476 2546700 51.6 1722 2918800 55.0 1968 3295

1000 61.1 2454 41451200 66.5 2941 4919

x2x0.5

6 11.2 26 12810 12.2 40 15820 13.9 78 21930 15.6 115 28250 18.8 196 41470 21.8 269 546

100 24.1 387 723150 28.6 580 1015200 32.0 766 1298250 36.3 952 1597300 37.8 1146 1877400 43.3 1526 2412500 48.8 1918 3013600 52.7 2292 3545700 55.1 2674 4066800 59.3 3056 4622

1000 68.6 3813 58201200 73.5 4570 6890

Construction data TPPV...

Number ofpairs

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0.6

6 11.9 36 14410 13.0 57 18520 15.7 111 28030 17.8 164 373

50 22.1 281 56170 24.9 387 724

100 28.2 557 983150 35.7 834 1450200 38.9 1102 1830250 43.7 1371 2257300 47.0 1650 2650400 53.6 2197 3472500 58.3 2761 4281600 64.8 3300 5128700 68.9 3851 5916800 73.6 4401 6749

x2x0.76

12.6 48 17110 14.3 77 22320 18.5 150 36730 21.1 222 48450 25.1 381 71870 28.0 526 930

100 34.3 757 1331150 41.0 1134 1917200 45.0 1500 2453250 50.4 1865 3029300 55.7 2245 3614400 62.3 2990 4676500 70.3 3757 5878600 76.5 4491 6986700 81.1 5240 8058

6 3 3-quads10 5 120 10 230 15 350 25 570 35 1 6

100 50 3 7150 75 3200 100 4250 125 5300 150 1 5400 200 4500 250 5600 300 1 5700 350 1 6

800 400 1 71000 500 3 71200 600 4 8

Page 369: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 369/430

Technical data

Color coding

Type codesT telephone cableP polyethylene insulationP polyethylene sheathB steel tape armourP PE protective sheath

Application

These cables are used as connecting cables in local networks and PABX's for telephone purposes and for transmis-sion of signals.Cables are suitable for laying in all types grounds.The use of these cables for power installations is not permitted.

C

O M M U N I C A T I O

N C A B L E S F O R

L O C A L N E T W O R K S

E L KA B E L

TPPBP . . . x2x0.4; TPPBP . . .ı2ı0.6

TPPBP . . . x2x0.5; TPPBP . . .ı2ı0.7

BDS 9096-83

368

Conductor diameter 0.4 0.5mm

Conductor resistance at 20∞C-max 150 95Ω/km

Conductor diameter 0.6 0.7mm

Conductor resistance at 20∞C-max 65 49Ω/km

Insulation resistance - min. 10GΩ.km

Mutual capacitance at 800Hz-nom. 48nF/km

Capacity unbalances at 800Hz:K1 100% of all values

95% of all valuesK9-K12 100% of all values

90% of all values

980pF/500m420pF/500m800pF/500m

200pF/m

Test voltage 50Hz, 2 min.wire-wire

wire-screen500V2000V

Operating voltage peak valuecables with cores 0.4 and 0.5mmcables with cores 0.6 and 0.7mm

150V220V

Temperature rangelaying and installing

exploitation and storage-10∞C ‰Ó +60∞C-50∞C ‰Ó +60∞C

Bending radius, min. approx. 10 x cablediameter

Cable construction

Conductor Bare copper conductor diameter0.4 mm, 0.5mm, 0.6mm and 0.7mm

Insulation PE low densityQuad 4 wires are twisted into a quadUnits 5 quads are twisted to a basic unitUnit marking In each layer there is a unit with red

supporting spiral form at which thecounting starts and a unit showingthe direction of counting - with yellowsupporting spiral.

Cable core The units are stranded into a cable Wrapping Several layers of plastic tapesScreen aluminum tape, thickness no less

than 0.04mm, one side coated withcopolymer and 1 tinned copper wirewith diameter of 0.5mm under thealuminum foil

Sheath PE low density with 2.5% carbonblack

Armour Two steel tapes - thickness 0.3mmProtective PE low density with 2.5% carbonsheath black

Number ofquad

Side-circuit -1 Side-circuit -2

a-wire b-wire a-wire b-wire

1 white red green blue

2 yellow red green blue

3 gray red green blue

4 brown red green blue

5 black red green blue

Page 370: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 370/430

369

C O M

M U N I C A T I O N C

A B L E S F O R L O

C A L N E T W O R K

S

Polyethylene insulation unit stranding laminated sheath armour PE protectivesheath

E L KA B E L

Cable core construction

Number ofpairs

Number ofquads

Number of units

5ı4 25ı4 50x4

1-st layer 2-nd layer 1-st layer 2-nd layer 1-st layer 2-nd layer

3 3-quads5 1

10 215 325 535 1 650 3 775 3

100 4125 5150 1 5200 4250 5300 1 5350 1 6

400 1 7500 3 7600 4 8

Construction data TPPBP...

Number ofpairs

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0.4

6 11.2 17 17610 13.0 27 22920 14.7 51 28930 16.5 74 35950 19.9 127 493

70 21.8 174 604100 24.9 250 766150 28.5 374 1061200 31.1 494 1257250 35.6 613 1533300 37.7 738 1718400 42.7 983 2482500 46.2 1235 2620600 50.4 1476 3044700 52.6 1722 3441800 55.4 1968 3828

1000 63.2 2454 47351200 68.3 2941 5568

x2x0.5

6 12.6 26 22110 13.7 40 26320 15.6 78 345

30 17.1 115 42350 20.8 196 59470 23.9 269 764

100 26.4 387 967150 31.1 580 1324200 34.7 766 1652250 39.2 952 1991300 40.4 1146 2290400 46.2 1526 2877500 51.7 1918 3517600 54.4 2292 4079700 58.0 2674 4633800 62.0 3056 5202

1000 71.4 3813 64721200 76.5 4570 7588

Construction data TPPBP...

Number ofpairs

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0.6

6 13.1 36 24110 14.1 57 27720 17.4 111 42230 19.8 164 54550 24.2 281 784

70 27.2 387 985100 30.7 557 1288150 38.4 834 1840200 41.5 1102 2238250 46.4 1371 2722300 49.9 1650 3146400 56.4 2197 4009500 59.5 2761 4820600 67.5 3300 5745700 71.9 3851 6569800 76.6 4401 7366

x2x0.7

6 14.1 48 27710 15.9 77 35220 20.4 150 54530 23.3 222 69750 27.4 381 981

70 30.5 526 1223100 36.9 757 1700150 43.7 1134 2343200 47.8 1500 2926250 53.2 1865 3549300 57.6 2245 4159400 65.8 2990 5138500 73.2 3757 6554600 79.5 4491 7695

Page 371: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 371/430

Technical data

Color coding

Type codesT telephone cableP polyethylene insulationP polyethylene sheathB steel tape armorP PE protective sheath

 areas with higher electromagnetic influences

Application

These cables are used as connecting cables in local networks and in PABX's for telephone purposes and for the trans-mission of signals.These cables are suitable for laying in ditches, in all types of grounds, in areas with high electromagnetic influences.The use of these cables for power installations is not permitted..

C O M M U N I C A T I O

N C A B L E S F O R L O C

A L N E T W O R K S W I T H

L O W

R E D U C T I O N F

A C T O R

E L KA B E L

TPPBPe. . . x2x0.4; TPPBPe. . . x2x0.6

TPPBPe. . . x2x0.5; TPPBPe. . . x2x0.7

BDS 9096-83

370

Cable construction

Conductor Bare copper conductor diameter0.4 mm, 0.5mm, 0.6mm and 0.7mm

Insulation PE low densityQuad 4 wires are twisted into a quadUnits 5 quads are twisted to a basic unitCable core

The units are stranded into a cable Wrapping Several layers of plastic tapesScreen aluminum tape, thickness no less

than 0.04mm, one side coated withcopolymer and 1 tinned copper wirewith diameter of 0.5mm under thealuminum foil

Sheath PE low density with 2.5% carbonblack

Additional Several layers of aluminum tapesscreen thickness 0.2mm

Armour Two galvanized steel tapes thickness0.5mm

Protective PE low density with 2.5% carbonsheath black

Conductor diameter 0.4 0.5mm

Conductor resistance at 20oC-max 150 95Ω/km

Conductor diameter 0.6 0.7mm

Conductor resistance at 20oC-max 65 49Ω/km

Insulation resistance - min. 10GΩ

.kmMutual capacitance at 800Hz-nom. 48nF/km

Capacity unbalances at 800Hz:K1 100% of all values

95% of all valuesK9-K12 100% of all values

90% of all values

980pF/500m420pF/500m800pF/500m

200pF/m

Test voltage 50Hz, 2 min.wire-wire

wire-screen500V2000V

Operating voltage peak value

Cables with cores 0.4 and 0.5mmCables with cores 0.6 and 0.7mm

150V220V

Reduction factor, at:Inductive voltage from 40 to 350 V/km,

and frequency 50Hz no more than:- cable with D above sheath up to 16mm

- cables with D above sheath over16mm to 37mm- cables with D above sheath > 37mm

0.60.50.4

Temperature rangelaying and installing

exploitation and storage-10∞C ‰Ó +60∞C-50∞C ‰Ó +60∞C

Bending radius, min. approx. 15 x cablediameter

Number ofquad

Side-circuit -1 Side-circuit -2

a-wire b-wire a-wire b-wire

1 white red green blue

2 yellow red green blue3 gray red green blue4 brown red green blue5 black red green blue

Unit markingIn each layer there is a unit with red supporting spiralfrom which the counting starts and a unit showing the

direction of counting - with yellow supporting spiral

Page 372: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 372/430

371

C O MM

U N I C A T I O N C A B L E S

F O R L O C A L N E T W O

R K S WI T H L O W

R E D

U C T I O N F A C T O R

olyethylene insulation unit stranding laminated sheath screen armour PE pro-tective sheath

E L KA B E L

Cable core construction

Number ofpairs

Number ofquads

Number of units

5ı4 25ı4 50x4

1-st layer 2-nd layer 1-st layer 2-nd layer 1-st layer 2-nd layer

20 10 230 15 350 25 570 35 1 6

100 50 3 7150 75 3200 100 4300 150 1 5

Construction data TPPBPÂ...

Number of pairs Diameter over sheath Outer diameter approx. Copper weight

mm kg/km kg/km

x2x0.4

20 10.7 17.5 5130 12.3 19.3 7450 15.5 23.5 12770 17.4 25.4 174

100 20.3 28.5 250150 23.7 32.1 374200 27.3 35.9 494300 32.5 41.3 738

x2x0.5

20 11.5 18.3 7830 13.7 20.7 11550 16.9 24.9 19670 19.1 27.3 269

100 22.3 30.7 387150 26.1 34.7 580200 30.5 39.3 766300 35.7 44.7 1146

x2x0.6

20 13.6 20.6 11130 15.8 23.8 16450 20.1 28.3 28170 22.3 30.7 387

100 26.2 34.8 557150 31.3 40.1 834200 36.2 45.2 1102300 43.3 54.1 1650

x2x0.7

20 15.3 22.3 15030 17.9 25.9 22250 23.0 31.4 38170 25.6 34.0 526

100 30.7 39.5 757150 36.3 45.3 1134

200 42.4 53.0 1500300 50.9 62.1 2245

Page 373: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 373/430

Cable construction

Conductor Bare copper conductor diameter0.4 mm, 0.5mm, 0.6mm and 0.7mm

Insulation PE insulation type 2YI2, according toVDE 0207 part 2.

Quad 4 wires are twisted into a quad

Units 5 quads are twisted to a basic unitCable core The units are stranded into a cableFilling Petroleum jelly

Wrapping Minimum one layer of paper tapeScreen aluminum tape, thickness 0.15mm,

coated with copolymer on both sidesSheath PE low density with 2.5% carbon

black

Technical data

Color coding

Type codesT telephone cableP polyethylene insulationJ petroleum jelly fillingP polyethylene sheath

Application

These cables are used as connecting cables in local networks and in PABX's for telephone purposes and for the trans-mission of signals. The filling of petrol jelly does not permit moisture penetration into the cable core.They are suitable for laying in cable pipes and conduits.The use of these cables for power installations is not permitted.These cables may only be used in locations with fire and explosion hazards in accordance with the appropriate safetyprecautions.

C

O M M U N I C A T I O

N C A B L E S F O R

L O C A L N E T W O R K S

E L KA B E L

TPJP. . . x2x0.4; TPJP. . . ı2ı0.6

TPJP. . . x2x0.5; TPJP. . . ı2ı0.7

FN KI 05 001-96

372

Conductor diameter 0.4 0.5mm

Conductor resistance at 20∞C-max 150 95Ω/km

Conductor diameter 0.6 0.7mm

Conductor resistance at 20∞C-max 65 49Ω/km

Insulation resistance - min. 5GΩ.kmMutual capacitance at 800Hz-nom. 55nF/km

Capacity unbalances at 800Hz:K1 100% of all values

95%of all valuesK9-K12 100% of all values

90% of all values

980pF/500m420pF/500m800pF/500m

200pF/m

Test voltage 50Hz, 2 min.wire-wire

wire-screen500V2000V

Operating voltage peak value

cables with cores 0.4 and 0.5mmcables with cores 0.6 and 0.7mm

150V220V

Temperature rangelaying and installing

exploitation and storage-10∞C ‰Ó +60∞C-40∞C ‰Ó +60∞C

Bending radius, min. approx. 10 ı cablediameter

Number ofquad

Side-circuit -1 Side-circuit -2

a-wire b-wire a-wire b-wire

1 white red green blue

2 yellow red green blue

3 gray red green blue

4 brown red green blue

5 black red green blue

Page 374: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 374/430

373

C O M

M U N I C A T I O N C

A B L E S F O R L O

C A L N E T W O R K

S

PE insulation unit stranding jelly filling laminated sheath.

E L KA B E L

Cable core construction

Number ofpairs

Number ofquads

Number of units

5ı4 25ı4 50x4

1-st layer 2-nd layer 1-st layer 2-nd layer 1-st layer 2-nd layer

6 3 3-quads10 5 120 10 230 15 350 25 570 35 1 6

100 50 3 7150 75 3200 100 4300 150 1 5400 200 4500 250 5600 300 1 5700 350 1 6800 400 1 7

1000 500 3 71200 600 4 8

Construction data TPJP...

Number ofpairs

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0.4

6 8.6 15 7710 9.3 24 9920 11.7 49 15930 12.9 73 22250 16.2 126 336

70 18.0 174 449100 21.7 252 604150 25.7 380 867200 30.6 504 1124300 35.4 724 1570400 42.3 965 2054500 43.4 1212 2514600 50.9 1449 2997700 54.3 1692 3480800 57.9 1934 3931

1000 64.1 2413 49231200 69.8 2893 5856

x2x0.5

6 9.2 23 9810 10.5 37 12920 12.9 75 22330 15.4 113 30650 19.9 196 48070 22.0 271 632

100 25.2 392 864150 30.8 592 1264200 36.5 784 1630300 42.5 1131 2320400 45.5 1508 3047500 52.0 1894 3772600 56.5 2260 4554700 62.0 2644 5210800 67.0 3022 5937

1000 76.0 3773 7373

Construction data TPJP..

Number ofpairs

Outer diame-ter approx.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0.6

6 10.4 32 12210 12.2 54 16520 16.2 108 29230 18.0 163 40250 22.9 282 638

70 26.5 390 851100 30.4 564 1187150 36.5 818 1656200 41.8 1085 2170300 48.9 1628 3225400 56.8 2170 4267500 63.0 2727 5283600 67.3 3261 6287700 73.6 3806 7298800 78.5 4351 8311

x2x0.7

6 11.4 44 14910 13.5 72 21020 17.8 148 36230 21.7 222 52250 27.0 384 81670 30.6 532 1087

100 36.1 768 1527150 42.0 1114 2193200 48.9 1476 2874300 58.5 2215 4311400 65.3 2953 5654500 74.7 3710 7012600 79.1 4437 8388700 81.9 5240 10211

Page 375: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 375/430

Cable construction

Conductor Bare copper conductor diameter0.4 mm, 0.5mm, 0.6mm and 0.7mm

Insulation PE insulation type 2YI2, according toVDE 0207 part 2.

Quad 4 wires are twisted into a quad

Units 5 quads are twisted to a basic unitCable core The units are stranded into a cableFilling Petroleum jelly

Wrapping Minimum one layer of paper tapeScreen aluminum tape, thickness 0.15mm,

coated with copolymer on both sidesSheath PE low density with 2.5% carbon

black Armour 2 steel tapes, thickness of 0.3mmProtective PE low density with 2.5% carbonsheath black

Technical data

Color coding

Type codesT telephone cableP polyethylene insulationJ petroleum jelly fillingP polyethylene sheathB steel tape armourP PE protective sheath

Application

These cables are used as connecting cables in local networks and in PABX's for telephone purposes and for the trans-mission of signals. The filling of petrol jelly does not permit moisture penetration into the cable core.They are suitable for laying in conduits in all types of grounds.The use of these cables for power installations is not permitted.

C

O M M U N I C A T I O

N C A B L E S F O R

L O C A L N E T W O R K S

E L KA B E L

TPJPBP ... x2x0.4; TPJPBP ... x2x0.6

TPJPBP ... x2x0.5; TPJPBP ... x2x0.7

FN KI 05 001-96

374

Conductor diameter 0.4 0.5mm

Conductor resistance at 20∞C-max 150 95Ω/km

Conductor diameter 0.6 0.7mm

Conductor resistance at 20∞C-max 65 49Ω/km

Insulation resistance - min. 5GΩ

.kmMutual capacitance at 800Hz-nom. 55nF/km

Capacity unbalances at 800Hz:K1 100% of all values

95% of all valuesK9-K12 100% of all values

90% of all values

980pF/500m420pF/500m800pF/500m

200pF/m

Test voltage 50Hz, 2 min.wire-wire

wire-screen500V2000V

Operating voltage peak value

cables with cores 0.4 and 0.5mmcables with cores 0.6 and 0.7mm

150V220V

Temperature rangelaying and installing

exploitation and storage-10∞C ‰Ó +60∞C-40∞C ‰Ó +60∞C

Bending radius, min. approx. 10 ı cablediameter

Number ofquad

Side-circuit -1 Side-circuit -2

a-wire b-wire a-wire b-wire

1 white red green blue

2 yellow red green blue

3 gray red green blue

4 brown red green blue

5 black red green blue

Page 376: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 376/430

375

C O M

M U N I C A T I O N C

A B L E S F O R L O

C A L N E T W O R K

S

E insulation unit stranding petrol filling laminated sheath armour protective PEsheath

E L KA B E L

Construction data TPJPBP...

Number of pairs Outer diameter approx. Copper weight Cable weight approx.

mm kg/km kg/km

s

6 12.6 15 23110 13.3 24 26320 15.9 49 36630 17.1 73 44250 20.6 126 61570 22.4 174 748

100 26.3 252 980150 30.7 380 1332200 35.8 504 1713

x2x0.5

6 13.2 23 25010 14.5 37 31220 17.1 75 44330 19.8 113 56850 24.5 196 84270 26.6 271 1015

100 30.0 392 1311150 36.0 592 1856200 42.1 784 2375

x2x0.6

6 14.4 32 30310 16.4 54 35020 20.6 108 57430 22.4 163 71650 27.7 282 105670 31.5 390 1361

100 35.6 564 1762x2x0.7

6 15.6 44 35010 17.7 72 45120 22.2 148 68530 26.3 222 931

50 32.0 384 158370 35.8 532 1699100 41.5 768 2302

Cable core construction

Number ofpairs

Number ofquads

Number of units

5ı4 25ı4

1-st layer 2-nd layer

6 3 3-quads.10 5 120 10 230 15 350 25 5 170 35 1 6

100 50 3 7150 75 3200 100 4

Page 377: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 377/430

Technical data

Color coding

Type codesT telephone cableP polyethylene insulationJ petroleum jelly fillingP polyethylene sheathP polyethylene protective sheath

Application

These cables are used as connecting cables in local networks and in PABX's for telephone purposes and for the trans-mission of signals. The filling of petro jelly does not permit moisture penetration into the cable core.They are suitable for underground installation, in cable ducts and conduit.The use of these cables for power installations is not permitted.These cables may only be used in locations with fire and explosion hazards in conjunction with the appropriate safetyprecautions

C

O M M U N I C A T I O

N C A B L E S F O R

L O C A L N E T W O R K S

E L KA B E L

TPJPP . . . x2x0.4; TPJPP . . .ı2ı0.6

TPJPP . . . x2x0.5; TPJPP . . .ı2ı0.7

FN KI 05 001-96

376

Cable construction

Conductor Bare copper conductor diameter0.4 mm , 0.5mm, 0.6mm, 0.7mm

Insulation Polyethylene insulation type 2YI2according to VDE 0207 part 2.

Quad each 4 wires are twisted to a quad

Units 5 quads laid up to a basic unitCable core the units are stranded into acompact cable

Filing petroleum - based jelly Wrapping minimum of 1 layer of paper tape.Screen of aluminum tape , thickness

0.15mm, coated with copolymer onboth sides

Sheath PE low density with 2.5% carbonblack

Protective PE low density with 2.5% carbonsheath black

Conductor diameter 0.4 0.5mm

Conductor resistance at 20∞C-max 150 95Ω/km

Conductor diameter 0.6 0.7mm

Conductor resistance at 20∞C-max. 65 49Ω/km

Insulation resistance min. 5GΩ

.kmMutual capacitance at 800Hz-max. 55nF/km

Capacitance unbalances at 800Hz:K1 100% of all values

95% of all valuesK9-K12 100% of all values

90% of all values

980pF/500m420pF/500m800pF/500m

200pF/m

Test voltage 50Hz, 2 min.wire-wire

wire - screen500V2000V

Operating voltage peak value

cables with cores 0.4 and 0.5mmcables with cores 0.6 and 0.7mm

150V220V

Temperature rangemobile

fixed-10∞C ‰Ó +60∞C-40∞C ‰Ó +60∞C

Minimum bending radius approx.10 x cablediameter

Number ofquad

Side-circuit -1 Side-circuit -2

a-wire b-wire a-wire b-wire

1 white red green blue

2 yellow red green blue

3 gray red green blue

4 brown red green blue

5 black red green blue

Page 378: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 378/430

377

C O M

M U N I C A T I O N C

A B L E S F O R L O

C A L N E T W O R K

S

PE insulation unit stranding filling laminated sheath protective PE

E L KA B E L

Cable construction TPJPP...

Numberof pairs

Externaldiameterapprox.

Copper weight

Cable weightapprox.

mm kg/km kg/km

x2x0.4

6 11.4 15 12010 12.1 24 14320 14.5 49 22030 15.7 73 28050 19.0 126 40870 20.8 174 528

100 24.5 252 699150 28.5 380 1223200 33.6 504 1264

x2x0.5

6 12.0 23 14110 13.3 37 17820 15.7 75 28230 18.2 113 37550 22.7 196 56770 24.8 271 727

100 28.0 392 972150 33.8 592 1405200 39.7 784 1810

x2x0.6

6 13.2 32 17010 15.0 54 22020 19.0 108 36430 20.8 163 48250 25.7 282 73770 29.3 390 964

100 33.4 564 1326x2x0.7

6 14.2 44 20110 16.3 72 27120 20.6 148 44030 24.5 222 616

50 29.8 384 93170 33.6 532 1227100 39.3 768 1703

Cable core construction

Numberof

pairs

Numberof

quads

Number of units

5ı4 25ı4

1-st layer 2-nd layer

6 3 3-÷åòâ.10 5 120 10 230 15 350 25 5 170 35 1 6

100 50 3 7150 75 3200 100 4

Page 379: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 379/430

Application

Cable construction

Conductor Copper stranded cores, 0.75mm2class 4

Insulation Solid PE insulation, according toBDS 10086-82

Sheath Two parallel laid cores with differ

ent color are covered with sheathof PVC, colored black type P-1,according to BDS 5792-84

PE insulation PVC sheath

378

R A D I O T

R A N S M I S S I O N

W I R E

E L KA B E L

PPVR ON 75713-83

Technical data

Conductor construction 11ı0.30

Circuit resistance at 20∞C- max., Ω/km 52

Insulation resistancemin,MΩ.km 200

Mutual capacitance -max.,pF/m 55

Nominal voltage, V 250

Test voltage 50Hz, 1 min., V 1000

Temperature rangeDuring exploitation

and storage-30∞C ‰Ó +50∞C

Construction data

N ı mm Outerdiameter

Copper weight Cable weight

mm ı mm kg/km kg/km

Type codesP- wireP- PE insulation

V- PVC sheath

R- for radio communication

Color coding

Two cores with different color

2x0.75mm2 3.5 ı 6.9 15 34

These wires are intended for maintenance and construction of radio relay system networks.

Page 380: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 380/430

379

R A D

I O T R A N S MI S S I O N WI R E

E L KA B E L

Cable construction

Conductor Copper stranded cores, 0.35mm2class 4

Insulation Solid PE insulation, according toBDS 10086-82

Sheath Two parallel laid cores with different

color are covered with sheath of PVC,color black type P-1, according toBDS 5792-84

PE insulation PVC sheath

Application

PPVAR ON 75713-83

Technical data

Construction data

N ı mm Outerdiameter

Copper weight Cable weight

mm ı mm kg/km kg/km2x0.35mm2 4.3 7 26

Color coding

Two cores with different color

Type codesP- wireP- PE insulationV- PVC sheath

¿- subscriber loopR- for radio communication

Conductor construction 7ı0.25

Circuit resistance at 20∞C- max., Ω/km 170

nsulation resistancemin,MΩ.km 100

Mutual capacitance -max.,pF/m 80

Nominal voltage, V 100

Test voltage 50Hz, 2 min., V 500

Temperature rangeDuring exploitation

and storage-30∞C ‰Ó +50∞C

These wires are intended for maintenance and construction of radio relay system networks.

Page 381: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 381/430

Cable construction

Conductor tinned copper conductor, diameter0.4 mm , 0.5mm, 0.6 mm and 0.8mm

Insulation PVC insulation class 1, accordingto BDS 5792-84

PMVS 1 wirePMVSUR- pairs 2 wires are twisted into a pair- triples 3 wires are twisted into a triple- quads 4 wires twisted into a quad

Tinned copper conductor PVC insulation single or stranded

380

Application

I N S T A L L A T I O

N W I R E S F O R C O M M U N I C

A T I O N S Y S T E M S A N D I N F O R M A T I O N P R O C E S S I N G S Y S T E M S

E L KA B E L

PMVSUR x0.4 ;PMVSUR x0.6 ;

PMVSUR x0.5 ,PMVSUR x0.8

PMVS 0.4, 0.5, 0.6, 0.8

BDS 11292-87

Technical data

Conductordiameter, mm 0.4 0.5 0.6 0.8

Conductor resistanceat 20∞C - max.,Ω/km 144 92 64 36.6

Insulation resistancemin., MΩ .km 300 300 300 300

Nominal voltage, V 380 380 660 660

Test alternating volt-age, 1 min. V 1500 1500 2500 2500

Construction data

N x mm Outer diame-ter approx.

Copper weight

Wire weightapprox.

mm ı mm kg/km kg/km

PMVSUR

2x0.4 1.6 2.30 3.30

2x0.5 1.82 3.80 5.00

2x0.6 2.4 5.70 7.90

2x0.8 2.8 9.20 11.80

3x0.4 1.7 3.50 5.10

3x0.5 2.0 5.60 7.50

3x0.6 2.6 7.90 11

3x0.8 3.0 13.60 18

4x0.4 1.9 4.60 6.70

4x0.5 2.2 7.70 11

4x0.6 2.9 11 15

4x0.8 3.4 18.50 24.50

PMVS

1x0.4 0.8 1.20 1.65

1x0.5 0.9 1.80 2.80

1x0.6 1.2 2.60 3.70

1x0.8 1.4 4.60 6.00

Type codesP- wireM installation

V PVC insulationS for communication systemsU strandedR for coupling

Color coding

PMVSUR PMVS2 ı... 3 ı... 4 ı... 1 ı...

wire ‡-white wire ‡-white wire ‡-white white

wire b-brown wire b-brown wire b-brown brown

wire Ò-green wire Ò-green green

wire d-yellow yellow

gray

blue

red

Installation cables are with copper tinned conductors and PVC insulation.Cables are intended for indoor electrical installation of communication equipment and installation systems of electricalconstructive groups and equipment, as well as processing information systems.These cables are not to be used for high power installation systems.Maximum allowed heat temperature of the conductors is +70∞C.

Page 382: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 382/430

381

T E L E P H O N E WI R E

E L KA B E L

Cable construction

Conductor Bare copper conductor diameter0.5mm

Insulation Solid PE insulation according toBDS 10086-82

Sheath Over 2 parallel laid cores with different colors, there is unifiedsheath of polyvinylchloride, color-white, black, gray type P-1according to BDS 5792-84

PE insulation PVC sheath

Application

PTPV 2x0.5 BDS 5627-80

Technical data

Conductor diameter 0.5mm

Conductor resistance at20∞C - max., Ω/km 95

Insulation resistance after3 hour idle time in water with

temperature 20+/- 5 meas-ured between each core andwater, and between both

cores, min., MΩ.km

200

Rated operating voltage with frequency

50Hz, V100

Tested voltage, V: Cableinsulation after 30min. idletime in water with tempera-

ture of 20 5 should withstandalternating current with fre-quency of 50Hz for a periodof 3 min., applied betweeneach wire and water, and

between both wires

500

Temperature rangeDuring exploitationand storage

-30∞C ‰Ó +50∞C

Construction data

No. ı mm Outer diameter approx.max. Copper weight Cable weight approx.

mm ı mm kg/km kg/km

Two different colored cores

Type codesP- wireT telephone

P PE insulation V PVC sheath

2x0.5 4.4 3.6 22

Color coding

The telephone cable PTPV is used for connecting telephones and loudspeakers to terminal equipments of city and localtelephone and radio relay system lines, for indoor and outdoor laying.

Page 383: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 383/430

Cable construiction

382

Application

J U M P E R

W I R E

E L KA B E L

YV x 0.4 / 0.8

YV x 0.5 / 0 .9

According to VDE 0812

Technical data

Conductor diameter, mm 0.4 0.5Cond. resistance at 20∞C

max

- single-wire, Ω/km- multi-wire, Ω/km

144148

92.295.0

Insulation resistance min. 200MΩ .km

Test voltage 50Hz, 1 min. : 1200V

Operating voltage peak value 500V

Temperature rangemobilefixed

-30∞C ‰Ó +50∞C-5∞C ‰Ó +60∞C

Minimum bending radiusapprox. 10 x cable diameter

Construction data

Number

of wires

Externaldiameterapprox

Copper

weight

Cable

weightapprox.

mm ı mm kg/km kg/km

Type codes V - tinned copper conductor Y - insulating cover of PVC

PVC insulation wires stranded

Color coding

Numberof wires Wire color

1 brown ,red, yellow. green, blue ,gray ,white ,black

2 white/brown, white/green, white/blue3 white/black/greena4 white/yellow/black/green5 white/yellow/black/green/gray

YV x 0,4/0,81 0,8 1,1 1,62 1,6 2,2 3,23 1,7 3,3 4,84 1,9 4,4 6,45 2,2 5,5 8,0

YV x 0,5/0,91 0,9 1,7 2,32 1,8 3,5 4,83 1,9 5,2 7,04 2,2 7,0 9,2

5 2,4 8,7 11,6

The jumper wire is used for wiring telephone and signal distributors.Tinned copper conductor with a diameter of 0.4, and 0.5mm PVC insulating cover.The operating voltages of the cables are 500 V.

Conductor solid tinned copper conductordiameter : 0.4 and 0.5mm

Insulation PVC insulation typeYI3according to VDE 0207, part4

Cable core the wires are stranded

into pairs, triples, quadsand quintuples

Page 384: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 384/430

Page 385: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 385/430

384 E L KA B E L

TSV/¿/V ı2ı0.4, TSV/¿/V ı3ı0.4

TSV/¿/V ı2ı0.5, TSV/¿/V x3ı0.5

According to FN KI05 002-96

and BDS 11509-79

Cable construction Technical data

Color coding

Application

These cables are used for installation of equipment of telephone stations.They are suitable for fixed indoor installation and for external walls of buildings.The screen of metal foil protects the cable from external electrical interferences.The use of these cables for power installations and underground installation is not permitted.

I N S T A L L A T I O N

C A B L E S F O R T E L E C O M M U N I C A T I O N S S Y S

T E M S

Conductor diameter 0.4 0.5mm

Conductor resistance at

20∞C - max.150 95Ω

Insulation resistance - min. 500MΩ.km

Mutual capacitance at

800Hz-max.120nF/km

Capacitance unbalances at

800Hz

K1- max. 50pF/100m

Test voltage 50Hz, 1 min. 1000V

Temperature range

laying and installing

exploitation and storage

-5∞C ‰Ó+50∞C

-20∞C ‰Ó+70∞C

Bending radius, min. approx.7.5 ı cable

diameter

Number of units.The units are counted succes-sively commencing at the outside and countinginwards in the same manner throught all layers

Colorsb- wires

1 6 11 16 21 26 31 36 41 462 7 12 17 22 27 32 37 42 473 8 13 18 23 28 33 38 43 484 9 14 19 24 29 34 39 44 495 10 15 20 25 30 35 40 45 50

blueyellowgreenbrownblack

51 56 61 66 71 76 81 86 91 9652 57 62 67 72 77 82 87 92 9753 58 63 68 73 78 83 88 93 9854 59 64 69 74 79 84 89 94 9955 60 65 70 75 80 85 90 95 100

blueyellowgreenbrownblack

Identification of the a-wire for the first unit(counting unit) is red in each layer , and white

for all other units .When the units are triples,the colour for a c-wire

is turquoise

Type codesT- telephone cableS- installation cable

V- insulation or sheath of PVC

(A) static screen of aluminium tapes

Conductor Bare copper conductor diameter0.4 mm and 0.5mm

Insulation PVC insulation class 1, according toBDS 5792-84

Units- pairs 2 wires are twisted to a pair- triples 3 wires are twisted to a tripleCable core the units are stranded into layers

Wrapping of plastic tapeScreen of aluminum tape one side coated

with copolymer and 1 tinned copperwire with diameter 0.5 mm

Sheath PVC class 2 according toBDS 5792-84 Color gray

Page 386: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 386/430

385

I N S T

A L L A T I O N

C A B

L E S F O R T E L E C

O MM U N I C A T I O

N S S Y S T E M S

E L KA B E L

PVC insulation pairs (triples) stranded in layers sheath of PVC

Cable core construction

Number ofpairs

(triples)

Number of pairs (triples) in layers

1 2 3 4 5 6

Cable core construction

Number ofpairs

(triples)

Number of pairs (triples) in layers

1 2 3 4 5 6

Construction data TSV/A/V

Number ofpairs

Outerdiameter

Copper weight

Cable weight

mm kg/km kg/km

Construction data TSV/A/V

Number ofpairs

Outerdiameter

Copper weight

Cable weight

mm kg/km kg/km

x2x0.4

1 4.1 3.5 15.90

2 4.4 5.9 32

3 5.4 8.30 36.80

4 5.8 10.60 42.60

5 6.2 13 50

6 6.6 15.35 57

8 6.9 20 61.3010 7.6 25 74

11 7.7 28 78

12 7.9 30 83

15 8.5 37 97

16 8.7 39.10 103

18 9.1 47.30 114

20 9.5 48.30 118.80

22 9.8 53 128

24 10.1 58 137

25 10.3 60.10 141

30 11 72 162

40 12.8 96 217

50 13.9 119 258

52 14.1 124 266.20

60 15.0 143 29980 16.8 190 380

100 18.9 237 479

x2x0.5

1 4.3 4.8 24.50

2 4.5 8.50 37

3 5.8 12.30 43.50

4 6.2 11 45.50

5 6.7 19.50 60

6 7.1 23.20 70

8 7.4 30.50 77.30

10 8.2 38 92

11 8.3 41.60 98

12 8.6 45.50 104.30

15 9.3 56.30 128

16 9.5 60.20 131.50

18 9.9 67 143

20 10.3 75 156

22 10.7 82 165.20

24 11.1 89 180

25 11.3 92.20 185

30 12.1 112 212

40 14.0 146 286

50 15.3 185 341

52 15.6 192 35360 16.5 217.50 401

80 19.0 290 533

100 20.8 368 640

x3x0.4

5 6.6 18 56

6 7.3 21 64

10 8.5 35 87

11 8.5 38 92

15 9.5 52 118

16 9.7 55 124

18 10.1 62 133

20 10.5 69 146

21 10.7 73 152

22 10.9 76 158

24 11.3 83 16625 11.5 86 175

35 13.5 121 148

x3x0.5

5 7.2 27 69

6 7.9 34 89

10 9.2 55 115

11 9.2 62 128

15 10.3 82 155

16 10.6 88 165

18 11.1 97 178

20 11.5 110 195

21 11.8 117 216

22 12.0 122 224

24 12.4 130 225

25 12.6 135 235

35 14.9 190 335

1 12 23 34 45 56 68 1 7

10 2 811 2 912 3 915 5 1016 5 1118 1 6 11

20 1 6 1321 1 7 1322 1 8 1324 2 8 1425 2 8 1530 4 10 1635 1 6 11 1740 1 7 13 1950 4 10 15 2152 4 10 16 2260 1 6 12 18 2380 4 10 16 22 28

100 2 8 14 20 25 31

Page 387: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 387/430

386

PVU-¿1 Uo/U - 300/500 V; Uo/U - 450/750 VBDS 4305-90

Cu conductors PVC insulation

Construction data PVU-¿1 300/500V 450/750V

Number of wires and nominalcross section Approx. outer diameter Copper weight

Approx.cable weight

mm2

mm kg/Ím kg/km

Cable construction

Construction According to BDS 4305-90

Conductor copper wires according toBDS 904-84, class 1(IEC 60228)

Insulation PVC compound, type I-2according to BDS 5792-84

Insulated cores are twisted

Technical data

Applications

Installation in lighting installations, power and distribution systems, machines, apparatus and other.For fixed

Color coding

Conductor resistance at 20oC according to BDS 904-84 class1

Operating temperatureof the conductor, max. 70oC

Rated voltage0.35 mm2 to 1 mm2

1.5 mm2 to 4 mm2Uo/U 300/500 VUo/U 450/750 V

Test voltage AC, 50 Hz:0.35 mm2 to 1 mm2

1.5 mm2 to 4 mm22000 V2500 V

Temperature of exploitation - 25oC to + 50oC

Minimum bending radiusFixed installation 6 x cable diameter

Testing BDS 4305-90

Flame test BDS IEC 332-1

Number of core With yellow/green Without yellow/green2 core - Blue, brown3 core yellow/green , blue , brown brown ,black , gray

C O N D U C T O

R S

F O R

E L E C T

R I C

I N S T A L L A T

I O N S

E L KA B E L

PVU-¿1 300/500V2ı0.35 4.0 6.6 162ı0.50 4.2 9.2 192ı0.75 4.5 13.4 242ı1.0 4.8 18.4 312ı1.5 5.8 27.6 452ı2.5 7.0 44 702ı4.0 7.8 71 100

PVU-¿1 450/750V3ı0.35 4.3 11 223ı0.50 4.6 13.8 283ı0.75 5.0 20.1 393ı1.0 5.2 27.6 493ı1.5 6.2 41.4 75

3ı2.5 7.5 66 1153ı4.0 8.4 106.5 157

Page 388: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 388/430

387

C O N

D U C T O R S

F O R

E L E C T R I C

I N S T

A L L A T I O N S

Uo/U - 300/500 V; Uo/U - 450/750 VBDS 4305-90

Cu conductors PVC insulationPVU-¿2

Construction data PVU-¿2 300/500V 450/750V

Number of wires and nominalcross section Approx. outer diameter Copper weight

Approx.cable weight

mm2

mm kg/Ím kg/km

Cable construction

Construction According to BDS 4305-90

Conductor copper wires according toBDS 904-84, class 5(IEC 60228)

Insulation PVC compound, type I-2according to BDS 5792-84

Insulated cores are twisted

Technical data

Applications

For fixed installation in lighting installations, power and distribution systems, machines, apparatus and other.

PVU-¿2 300/500V2ı0.35 4.1 7 15.52ı0.50 4.5 9.2 182ı0.75 4.8 15 252ı1.0 5.1 19.2 292ı1.5 6.2 28 442ı2.5 7.3 48 682ı4.0 8.4 76 100

PVU-A2 450/750V3ı0.35 4.5 10 233ı0.50 4.9 14 283ı0.75 5.2 20.5 393ı1.0 5.6 27.6 493ı1.5 6.7 41.4 75

3ı2.5 7.9 66 1153ı4.0 9.1 107 157

Color coding

Conductor resistance at 20oC according to BDS 904-84 class 5

Operating temperatureof the conductor, max. 70oC

Rated voltage0.35 mm2 to 1 mm2

1.5 mm2 to 4 mm2Uo/U 300/500 VUo/U 450/750 V

Test voltage AC, 50 Hz:0.35 mm2 to 1 mm2

1.5 mm2 to 4 mm22000 V2500 V

Temperature of exploitation - 25oC to + 50oC

Minimum bending radiusfixed installation 4 x cable diameter

Testing BDS 4305-90

Flame test BDS IEC 332-1

Number of core With yellow/green Without yellow/green2 core - black , brown3 core yellow/green , blue , brown Brown, black, gray

E L KA B E L

Page 389: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 389/430

Applications

For fixed installation in lighting installations, power and distribution systems, machines, apparatus and other.

388

C O N D U C T O

R S

F O R

E L E C T

R I C

I N S T A L L A T

I O N S

PVV-¿3 Uo/U - 300/500 V; Uo/U - 450/750 VBDS 4305-90

E L KA B E L

Construction data PVV-¿3 300/500V 450/750V

Number of wires and nominalcross section Approx. outer diameter Copper weight Approx.cable weight

mm2 mm kg/Ím kg/km

Cable construction

Construction According to BDS 4305-90

Conductor copper wires according toBDS 904-84 (IEC 60228)class 1 - 0.5 mm2 to 10mm2

class 2 - 16 mm2 to 35 mm2

Insulation PVC compound, type I-2according to BDS 5792-84

Sheath PVC compound, type P-1according to BDS 5792-84

Color black, gray, white

Technical data

Conductor resistance at 20oC according to BDS 904-84class 1 or 2

Operating temperature ofthe conductor, max. 70oC

Rated voltage0.5 mm2 to 1 mm2

1.5 mm2 to 35 mm2Uo/U 300/500 VUo/U 450/750 V

Test voltage AC, 50 Hz:0.5 mm2 to 1 mm2

1.5 mm2 to 35 mm22000 V2500 V

Temperature range - 25oC to + 50oCBending radius up to fixed

installation 6 x cable diameter

Testing BDS 4305-90Flame test BDS IEC 332-1

PVV-¿3 300/500V2ı0.50 5.5 9 352ı0.75 5.8 13.5 482ı1.0 6.1 19 55

PVV-¿3 450/750V2ı1.5 7.4 28 782ı2.5 8.6 44 1122ı4.0 9.9 71 1902ı6.0 11.3 110 2222ı10 13.7 176 3202ı16 16.7 280 4362ı25 20.4 440 6612ı35 22.7 610 856

Number of core With yellow/green Without yellow/green2 core - blue, brown3 core yellow/green , blue , brown brown, black, gray4 core yellow/green , brown ,black , gray blue, brown, black, gray

4 core with reduction core yellow/green*, brown ,black , gray blue*, brown, black, gray5 core yellow/green , blue , brown , black, gray black , blue , brown , black , gray

Color coding

* reduction core

Page 390: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 390/430

389

C O N

D U C T O R S

F O R

E L E C T R I C

I N S T

A L L A T I O N S

E L KA B E L

Construction data PVV-¿3 300/500V 450/750V

Number of wires and nominalcross section Approx. outer diameter Copper weight

Approx.cable weight

mm

2

mm kg/Ím kg/kmPVV-¿3 300/500V

3ı0.50 6.2 14 503ı0.75 6.6 21 603ı1.0 6.9 28 72

PVV-¿3 450/750V3ı1.5 8.3 41 1083ı2.5 9.5 66 1523ı4.0 10.9 107 2103ı6.0 12.4 165 2983ı10 14.9 264 4423ı16 18.2 425 6423ı25 22.2 660 9573ı35 24.7 927 1275

PVV-¿3 300/500V

4ı0.50 6.8 18 624ı0.75 7.2 27 784ı1.0 7.5 37 90

PVV-¿3 450/750V4ı1.5 9 55 1324ı2.5 10.4 89 1904ı4.0 11.9 142 2504ı6.0 13.5 218 3514ı10 16.3 358 5804ı16 20 580 8904ı25 24 880 12354ı35 27.2 1236 16833ı25+16 23 809 11503ı35+25 26.5 1130 1550

PVV-¿3 300/500V

5ı0.50 7.6 22 745ı0.75 8.0 34 92

Cu conductors PVC insulation PVC sheath

Page 391: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 391/430

Construction data PVV-MB1 220/380V

Number of wires and nominalcross section

Outer dimensionsapprox. Copper weight

Approx.cable weight

mm2

mm kg/Ím kg/km

Cable construction

Construction According to BDS 4305-90

Conductor copper wires according to BDS 904-84,class 1 (IEC 60228)

Insulation PVC compound, type I-2according to BDS 5792-84

Insulated cores are parallel in between in a unified sheath

Sheath PVS compound, type P-1according to BDS 5792-84

Color white, gray, black

390

C O N D U C T O

R S

F O R

E L E C T

R I C

I N S T A L L A T

I O N S

PVV-MB1 Uo/U - 220/380 VBDS 4305-90

Cu conductors PVC insulation PVC sheath

Technical data

Applications

For fixed installation in power and distribution installations for home buildings and production buildings, underneathwall plastering.

2ı1.0 3.4 ı 9.8 18 452x1.5 3.9 ı 10.8 27 692x2.5 4.6 ı 12.2 44 992x4.0 5.2 ı 13.6 71 1402ı6.0 6.2 ı 15.4 110 1803ı1.0 3.4 ı 16.2 27 703x1.5 3.9 ı 17.7 41 1093x2.5 4.6 ı 19.8 66 1553x4.0 5.3 ı 21.9 110 2173ı6.0 6.2 ı 24.6 165 2804ı1.0 3.4 ı 22.6 36 954x1.5 3.9 ı 24.6 54 1484x2.5 4.6 ı 27.4 88 2105ı1.0 3.4 ı 29.0 45 120

5x1.5 3.9 x 31.5 68 1885x2.5 4.6 x 35.0 110 265

Color coding

Conductor resistance at 20oC according to BDS 904-84 class 1

Operating temperature ofthe conductor, max. max 70oC

Rated voltage Uo/U 220/380 V

Test voltage AC, 50 Hz 2000 V

Temperature of exploitation - 25oC to + 50oC

Minimum bending radiusFixed installation 6 x narrow side of conductor

Testing BDS 4305-90

Flame testBDS IEC 332-1

Number of core With yellow/green Without yellow/green2 core - blue, brown3 core yellow/green , blue , brown brown, black, gray4 core yellow/green , brown ,black , gray blue, brown, black , gray5 core yellow/green , blue , brown , black, gray black , blue , brown , black , gray

E L KA B E L

Page 392: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 392/430

391

C O N

D U C T O R S

F O R

E L E C T R I C

I N S T

A L L A T I O N S

U - 660VBDS 6767-81 PVOT-2

Cu conductors PVC insulation Pb sheath PVC sheath

E L KA B E L

Cable construction

Construction According to BDS 6767-81Conductor copper wires according to

BDS 904-84 (IEC 60228)class 1 - 0.5 mm2 to 6 mm2

class 1 and 2 - 10 mm2

Insulation PVC compound, type I-2according to BDS 5792-84

Filling rubber or PVC compoundLead sheath according to BDS 4712Underneath the lead sheath are laid one or several bare copperconductors with total nominal cross section no less than 1 mm2

Sheath PVC compound, type P-1according to BDS 5792-84

Color gray, black

Technical data

Applications

For fixed laying installation over, on and underneath plaster, in dry and wet rooms, as well outdoor where there is no danger ofmechanical impact during installation and exploitation. These cables can also be used if present are steam, gases, and acid, which

can be very destructive to the lead sheath, but which cannot damage the thermoplastic protective sheath. The cables can be usedin all types of fire hazardous and explosion hazardous premises, with the exception of cables class BI.

Color coding

Conductor resistance at 20oC according to BDS 904-84class 1 or 2

Operating temperature ofthe conductor, max. max 70oC

Rated voltage 660 V

Test voltage AC, 50 Hz 2500 V

Temperature of exploitation - 30oC to + 50oC

Minimum bending radiusfixed installation 6 x cable diameter

Testing BDS 6767-81

Number of core With yellow/green Without yellow/green

2 core - black , blue

3 core yellow/green , blue, brown blue, black , brown

4 core yellow/green, brown, black , gray blue, black , brown , black

4 core with reduction core yellow/green*, brown, black , gray blue, black , brown , black

5 core yellow/green, blue, brown , black , gray blue, black , brown , black , black

Construction data PVOT-2 660VNumber of wires

and nominalcross section

Approx.outer diame-

terCopper weight

Approx.cable weight

mm2 mm kg/Ím kg/km

2ı1.0 10.3 28 3432x1.5 10.8 37 4062x2.5 12.0 55 4502x4.0 13.8 82 5702ı6.0 14.8 120 6602ı10 17.3 185 10203ı1.0 10.6 37 3703x1.5 11.2 53 4103x2.5 12.9 78 5203x4.0 14.4 125 631

3ı6.0 15.7 171 8003ı10 19.6 273 1100

Construction data PVOT-2 660VNumber of wires

and nominalcross section

Approx.outer diame-

terCopper weight

Approx.cable weight

mm2 mm kg/Ím kg/km

3ı1.5+1.0 11.6 61 4453ı2.5+1.5 13.4 90 5603ı4+2.5 15.0 142 6903ı6+4.0 16.6 210 8903ı10+6.0 20.7 280 12604ı1.0 11.0 48 4494x1.5 11.9 67 5004x2.5 13.8 99 6204ı4.0 15.6 149 8104ı6.0 17.0 225 960

4ı10 22.0 360 1300

* reduction core

Page 393: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 393/430

Construction data Cu/PVC/PVC 300/500V

Number of wires andnominal cross section Approx. outer diameter Copper weight

Approx.cable weight

mm2

mm kg/Ím kg/km

Cable construction

Construction According to BS 6004

Conductor copper wires accordingto BS 6360 (IEC 60228)class 1 - 1 mm2 to 2.5mm2

class 2 - 1.5 mm2 to 35 mm2

Insulation PVC compound, type TI 1according to BS 7655 - 3.1

Insulation color red or black

Sheath PVC compound, type 6according to BS 7655 - 4,2

Color gray or black

Technical data

Applications

For fixed installation in lighting installations, power and distribution systems.

C O N D U C T O

R S

F O R

E L E C T

R I C

I N S T A L L A T

I O N S

Cu/PVC/PVC Uo/U - 300/500VBS 6004

Cu conductors PVC insulation PVC sheath

class 11.0 4.0 9.2 281.5 4.5 13.8 362.5 5.0 23 50

class 21.5 4.7 14.4 362.5 5.3 23 524.0 6.0 37 806.0 6.6 56 115

10 7.9 93 14516 8.8 152 23025 10.6 228 34035 11.7 320 400

Conductor resistance at 20oC according to BS 6360 class 1 or2

Operating temperature ofthe conductor, max. 70oC

Rated voltage Uo/U 300/500 V

Test voltage AC, 50 Hz: 2000 V

Temperature of exploitation - 25oC to + 50oC

Minimum bending radiusFixed installation 6 x cable diameter

Testing acc. to BS 6004

Flame test IEC 60 332-1

E L KA B E L

Page 394: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 394/430

393

C O N

D U C T O R S F O R

O V E R H E A D L I N

E S

Uo/U - 0.6/1 kVFN KI 06 003-06 PVO

Cu conductors PVC insulation

E L KA B E L

Construction data PVO 0.6/1 kV

Nominal cross section Outer diameterapprox. Copper weight Cable weight

approx.

mm2

mm kg/Ím kg/km

Cable construction

Construction According to FN KI 06 003-06

Conductor copper wires according toBDS 904-84 (IEC 60228)class 1 - 6 mm2 and 10mm2

class 2 - 16 to 70 mm2

Insulation PVC compound, type Iaccording to BDS 5792-84

Insulation color black

Technical data

Application

For connecting home and other electrical installations to open-air electrical distribution network.

6 4.8 55 7310 6.0 91 12016 7.5 152 19125 9.3 225 30035 10.4 315 40050 12.1 420 53070 13.9 620 745

Conductor resistanceat 20∞C according to BDS 904-84

Operating temperature of theconductor, max. 70∞C

Rated voltage Uo/U 0.6/1 kV

Test voltage AC, 50 Hz 4 kV

Temperature of exploitation - 30∞C to + 50∞C

Minimum bending radiusFixed installation 6 x cable diameter

Testing FN KI 06 003-06

Flame test BDS IEC 332-1

Page 395: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 395/430

394

C O N D U C T

O R S

F O R

E L E

C T R I C

T E L P H

E R S

ShKPSSUo up to 380 VBDS 11321-90

Cu conductors EPR insulation St core EPR sheath

E L KA B E L

Cable construction

Construction According to BDS 11321-90

Conductor Cu wires , flexible, class 5 accordingto BDS 904-84

Insulation Silane crosslinked EPR rubber compound

Core identification according to BDS 11321-90

Cable core supporting steel cord, insulated withrubber compound

Sheath Silane crosslinked EPR rubber compound

Color black

Technical data

Application

ShKPSS are used for command chains of electric telphers with nominal voltage up to 380V. Cables for 380V can beused also for 500V.

Operating temperature of theconductor, max. +60∞C

Rated voltage up to 380 V

Test voltage AC, 50 Hz 2000 V

Ambient temperature duringexploitationFor ShKPSS

For ShKSSN and ShKPSSM-T- 40∞— to +50∞—- 30∞— to +50∞—

Testing

Testing: Insulation resistance BDS 1986-82

Testing: Resistance to oil BDS 6200-83

Color coding

Number of cores Without yellow/green With yellow/green3 brown ,black, gray yellow/green, blue, brown4 blue, brown, black, gray yellow/green, brown, black, gray5 black, blue, brown, black, gray yellow/green, blue, brown, black, gray

Construction data ShKPSSNumber of

conductors andnominal cross

section

Outer diameterapprox.

Copperweight

Cable weightapprox.

220 V 380 V

mm2

220 V (mm) 380 V (mm) kg/Ím kg/km kg/km

Construction data ShKPSSNumber of

conductors andnominal cross

section

Outer diameterapprox.

Copperweight

Cable weightapprox.

220 V 380 V

mm2

220 V (mm) 380 V (mm) kg/Ím kg/km kg/km

5x1.5 - 14.0 65.0 - 1906x1.5 - 14.5 77.0 - 2107x1.5 - 15.0 90.0 - 2408x1.5 - 17.0 103.0 - 2709x1.5 - 17.5 115.0 - 300

10x1.5 - 18.5 129.0 - 33011x1.5 - 19.5 142.0 - 38012x1.5 - 20.5 155.0 - 420

3x0.75 11.0 - 20.0 100 -4x0.75 11.5 - 27.0 105 -5x0.75 12.0 - 35.0 115 -6x0.75 12.5 - 40.0 130 -7x0.75 13.0 - 48.0 150 -8x0.75 14.0 - 55.0 170 -9x0.75 15.0 - 60.0 190 -3x1.0 12.0 - 27.0 105 -4x1.0 12.5 - 35.0 120 -5x1.0 13.0 - 45.0 1306x1.0 13.5 - 55.0 150 -7x1.0 14.0 - 62.0 170 -8x1.0 14.5 - 70.0 190 -9x1.0 15.5 - 80.0 220 -3x1.5 - 13.0 39.0 - 1404x1.5 - 13.5 51.0 - 170

Page 396: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 396/430

395

Uo/U - 300/500 V.O. VE /

.O.NORM E 8241-55 XYMM K35

E L KA B E L

Construction data XYMM K35 Uo/U - 300/500 V

Number of wires andnominal cross section

Outer diameterapprox. Copper weight Cable weight

approx.

mm2

mm kg/Ím kg/km

Cable construction

Conductor copper wires according toIEC 60228 Class 5

Insulation: PVC, compound Type TI4 ,according to HD 21.1

Sheath PVC, compound type TM4according to HD 21.1

Color: black or white as standard color,

Different colors available upon request.

Technical data

Application

The cables are suitable for connection of medium duty appliances in houses, kitchens and offices, for house appli-ances in wet premises i.e. refrigerators, washing machines, centrifuges as far as this is allowed in the instructions ofthe electrical appliances. It is allowed they to be used for connection of electrical heating appliances providing the con-ductors are not in contact with the heated parts and they shall not be subject of other thermal effects. The cables can

be installed in furniture, finished building elements and in decorative edgings.

2ı1.5 8.4 25 953ı1.5 8.9 37 1144ı1.5 9.6 49 1385ı1.5 10.9 62 1733ı2.5 10.6 62 1704ı2.5 11.6 82 2075ı2.5 12.8 103 2504ı4 13.1 134 2865ı4 15.1 168 3654ı6 14.9 200 3775ı6 16.5 250 4594ı10 19.3 362 6505ı10 21.4 453 789

Color coding

Conductor resistance at 20∞C according to and IEC 60228 cl. 5

Core temperature max 70∞C in operation150∞C in the event of a short circuit

Rated voltage for Uo/U 300/500 V

Test voltage AC, 50 Hz 2000 V

Temperature range

mobile: -25∞C to +70∞C

fixed: -40∞C to +70∞C

Flame test

test class B ,VDE 0472part 804

and IEC 60 332-1

Number of core With yellow/green Without yellow/green2 core - blue, brown3 core yellow/green , blue , brown brown, black , gray4 core yellow/green , brown ,black , gray blue, brown, black , gray5 core yellow/green , blue , brown , black, gray black , blue , brown , black , gray

C O N

D U C T O R S WI T H C O L D -R E S I S T

A N T P V C

Cu conductors PVC insulation PVC sheath, cold - resistant

Page 397: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 397/430

Identification of cable wires

Construction data SPC Uo/U - 600/1000 V

Number of wires andnominal cross section

Outer diameterapprox. Copper weight Cable weight

approx.

mm2 mm kg/Ím kg/km

Cable construction

Conductor solid copper conductorto BS 6360

Conductor accorting to BS 6360size

Insulation PVC type TI1 complying tomaterial BS 7655

Phase conductor phase conductor, class 2

Neutral conductor split concentric cables, class 1

Eart conductor split concentric cables, class 1

Outer PVC compound type TM1sheath complying to BS 7655-4.1

Sheath colour Black or violet

Technical data

396

Application

Cables can be used for household and street lightning, suitable for fixed installations in direct burial.

S P L I T C

O N C E N T R I C C

A B L E

SPCUo/U - 600/1000 V

Cu conductors PVC insulation Split concentric neutral sheath of PVC

1ı4/4+4 10 113 2011ı6/6+6 11.5 178 2771ı10/10+10 13.0 277 3911ı16/16+16 15.0 441 5761ı25/25+16 18.0 608 7901ı35/35+25 22.0 855 1097

Conductor resistanceat 20∞— According to BS 6360

Insulation resistanmin. MΩ.km 100

Voltage rating 600/1000 V

Test voltage 50Hz, 1 min.

wire - wire 3500V

wire - eart 3500V

Temperature range, mobile -5∞C to +50∞C

Temperature range, fixed - 30∞C to +70∞C

Minimum bending radiusapprox. 15 x cable diameter

Single phase conductor brawn

Neutral conductor blue

Eart conductor plain annealed copper wires

E L KA B E L

Page 398: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 398/430

T E C H N I C A L D A T A

T E C H N I C

A L D A T A

E L KA B E L

Page 399: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 399/430

398

T E C H N I C A L

D A T A

E L KA B E L

Page 400: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 400/430

399

Wooden drums as per BDS -maximal length in meters

KD DMIN DMAX 107 109 111 112 115 117 118 120 124 125 126 130

** ** A3a A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14

D ** 650 800 1000 1200 1400 1700 1800 2000 2200 2450 2600 300

d ** 340 450 500 600 750 900 1100 1200 1300 1500 1500 1800

H ** 400 400 500 500 700 750 900 1000 1000 1300 1500 1800

D9 ** 676 838 1048 1248 1464 1764 1864 2064 2280 2550 2720 3150

H9 ** 530 530 630 630 880 940 1120 1230 1300 1600 1820 2200

kg 250 400 700 1000 1600 2200 2800 3500 4000 5000 7000 10000

126 1.9510 2.0600 14430 0 0 0 0 0 0 0 0 0 0 0

127 2.0610 2.2000 12609 0 0 0 0 0 0 0 0 0 0 0

128 2.2010 2.3000 11675 0 0 0 0 0 0 0 0 0 0 0129 2.3010 2.4000 10580 15178 0 0 0 0 0 0 0 0 0 0

130 2.4010 2.5000 9828 14176 0 0 0 0 0 0 0 0 0 0

131 2.5010 2.6000 9036 13111 0 0 0 0 0 0 0 0 0 0

132 2.6010 2.8000 7910 11319 0 0 0 0 0 0 0 0 0 0

133 2.8010 3.0000 6741 9778 0 0 0 0 0 0 0 0 0 0

134 3.0010 3.2000 6449 9170 0 0 0 0 0 0 0 0 0 0

135 3.2010 3.4000 5571 8010 0 0 0 0 0 0 0 0 0 0

136 3.4010 3.6000 5011 7262 15489 0 0 0 0 0 0 0 0 0

137 3.6010 3.8000 4473 6541 13641 0 0 0 0 0 0 0 0 0

138 3.8010 4.0000 3999 5908 12596 0 0 0 0 0 0 0 0 0

139 4.0010 4.2000 3698 5301 11281 0 0 0 0 0 0 0 0 0

140 4.2010 4.4000 3259 4720 10301 14634 0 0 0 0 0 0 0 0

141 4.4010 4.7000 2997 4192 9063 13050 0 0 0 0 0 0 0 0

142 4.7010 5.0000 2611 3686 7963 11644 0 0 0 0 0 0 0 0

143 5.0010 5.3000 2246 3356 7149 10294 0 0 0 0 0 0 0 0

144 5.3010 5.6000 2044 2936 6219 9112 0 0 0 0 0 0 0 0

145 5.6010 5.9000 1849 2673 5753 8234 14805 0 0 0 0 0 0 0

146 5.9010 6.2000 1688 2329 5163 7482 13460 0 0 0 0 0 0 0

147 6.2010 6.6000 1417 2098 4558 6475 11844 0 0 0 0 0 0 0

148 6.6010 7.0000 1277 1908 4038 5815 10654 0 0 0 0 0 0 0

149 7.0010 7.4000 1209 1826 3751 5485 10068 0 0 0 0 0 0 0

150 7.4010 7.8000 1072 1639 3472 4920 9010 14848 0 0 0 0 0 0

151 7.8010 8.3000 946 1364 3001 4321 8025 13345 15377 0 0 0 0 0

152 8.3010 8.8000 825 1203 2703 3752 7082 11652 13720 0 0 0 0 0

T E C H

N I C A L D A T A

E L KA B E L

Page 401: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 401/430

KD DMIN DMAX 107 109 111 112 115 117 118 120 124 125 126 130

** ** A3a A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14

153 8.8010 9.3000 800 1075 2323 3444 6271 10412 12139 0 0 0 0 0

154 9.3010 9.8000 687 1013 2137 3205 5758 9349 10760 0 0 0 0 0

155 9.8100 10.4000 599 896 1922 2767 5026 8352 9472 13823 0 0 0 0

156 10.4100 11.0000 516 785 1714 2496 4565 7397 8638 12156 0 0 0 0

157 11.0100 11.6000 494 680 1551 2154 3967 6775 7565 11292 14008 0 0 0

158 11.6100 12.3000 419 649 1363 1914 3555 5911 6911 9904 12412 0 0 0

159 12.3100 13.0000 399 553 1217 1729 3219 5188 6277 8593 10895 0 0 0

160 13.0100 13.8000 331 466 1079 1554 2901 4752 5364 7863 9613 15261 0 0

161 13.8100 14.6000 324 455 948 1386 2423 4099 4802 6791 8795 14036 0 0

162 14.6100 15.5000 262 375 825 1228 2192 3705 4345 6135 7634 12156 0 0

163 15.5100 16.4000 270 385 749 1136 2030 3510 4047 5808 7279 11258 0 0

164 16.4100 17.4000 212 309 711 987 1810 3203 3612 5267 6298 10164 14281 0

165 17.4100 18.4000 206 299 623 879 1745 2834 3196 4745 5708 9241 13033 0

166 18.4100 19.5000 164 215 519 828 1496 2374 2868 3963 5145 7899 11270 0

167 19.5100 20.6000 158 236 506 728 1303 2114 2495 3506 4604 7190 10286 0168 20.6100 22.0000 121 188 412 608 1126 1872 2151 3082 4100 6417 8858 14203

169 22.0100 23.5000 116 180 401 523 960 1592 1881 2683 3622 5682 7871 12210

170 23.5100 25.0000 111 137 334 507 942 1567 1805 2591 3247 5079 7163 11110

171 25.0100 26.5000 0 130 306 405 788 1352 1508 2217 2812 4502 5948 9318

172 26.5100 28.0000 0 123 247 389 673 1151 1318 1925 2474 3954 5314 8463

173 28.0100 29.5000 0 116 236 319 627 1005 1249 1652 2155 3517 4708 7639

174 29.5100 31.0000 0 0 197 324 524 978 1074 1619 1916 3027 4575 6848

175 31.0100 32.5000 0 0 187 259 506 841 1010 1365 1816 2984 4093 6093

176 32.5100 34.0000 0 0 176 245 488 814 852 1333 1594 2597 3633 5820

177 34.0100 35.5000 0 0 142 248 396 688 826 1143 1554 2234 3505 5221

178 35.5100 37.0000 0 0 133 191 379 662 800 1112 1346 2191 3074 4649

179 37.0100 38.5000 0 0 124 179 383 636 658 1038 1257 2084 2670 4496

180 38.5100 40.0000 0 0 125 181 301 524 634 907 1268 1815 2624 4051

181 40.0100 41.5000 0 0 127 182 286 529 610 878 1079 1772 2576 3903

182 41.5100 43.0000 0 0 0 134 289 505 486 848 1042 1521 2202 3401

183 43.0100 44.5000 0 0 0 135 273 405 490 695 870 1480 2155 3344

184 44.5100 46.0000 0 0 0 124 276 408 468 668 836 1440 1872 2952

185 46.0100 47.5000 0 0 0 125 206 386 446 672 842 1212 1827 2821

186 47.5100 49.0000 0 0 0 126 208 390 449 645 808 1175 1782 2764

187 49.0100 50.5000 0 0 0 0 194 302 343 511 656 1137 1522 2408

188 50.5100 52.0000 0 0 0 0 196 304 345 514 661 974 1480 2354

400

T E C H N I C A L

D A T A

Wooden drums as per BDS -maximal length in meters

E L KA B E L

Page 402: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 402/430

KD DMIN DMAX 107 109 111 112 115 117 118 120 124 125 126 130

** ** A3a A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14

189 52.0100 53.5000 0 0 0 0 150 306 327 490 630 940 1490 2300

190 53.5100 55.0000 0 0 0 0 139 286 328 493 634 906 1251 1973

191 50.0100 56.5000 0 0 0 0 140 288 309 469 499 911 1212 1922

192 56.5100 58.0000 0 0 0 0 141 213 311 378 502 876 1172 1933

193 58.0100 59.5000 0 0 0 0 130 214 240 358 475 698 1179 1882

194 59.5100 61.0000 0 0 0 0 131 216 225 359 477 702 966 1584

195 61.0100 62.5000 0 0 0 0 131 217 226 361 480 672 971 1538

196 62.5100 64.0000 0 0 0 0 0 200 227 340 363 675 936 1546

197 64.0100 65.5000 0 0 0 0 0 201 211 342 364 644 900 1498

198 65.5100 67.0000 0 0 0 0 0 153 212 245 342 647 905 1232

199 67.0100 68.5000 0 0 0 0 0 140 213 246 343 495 868 1238

200 68.5100 70.0000 0 0 0 0 0 141 198 247 345 497 722 1196

201 70.0100 71.5000 0 0 0 0 0 142 141 231 322 499 691 1202

202 71.5100 73.0000 0 0 0 0 0 142 142 232 323 473 694 1159

203 73.0100 74.5000 0 0 0 0 0 143 142 232 248 475 697 966204 74.5100 76.0000 0 0 0 0 0 129 131 233 249 477 665 929

205 76.0100 77.5000 0 0 0 0 0 130 131 216 231 451 669 933

206 77.5100 79.0000 0 0 0 0 0 131 132 217 232 452 509 896

207 79.0100 80.5000 0 0 0 0 0 0 132 155 232 348 511 899

208 80.5100 82.0000 0 0 0 0 0 0 121 155 233 327 513 862

209 82.0100 83.5000 0 0 0 0 0 0 121 143 215 328 486 865

210 83.5100 85.0000 0 0 0 0 0 0 121 143 215 329 488 869

211 85.0100 86.5000 0 0 0 0 0 0 122 144 216 331 490 666

212 86.5100 88.0000 0 0 0 0 0 0 0 144 217 310 492 669

213 88.0100 89.5000 0 0 0 0 0 0 0 145 218 311 465 671

214 89.5100 91.0000 0 0 0 0 0 0 0 132 141 312 356 639

215 91.0100 92.5000 0 0 0 0 0 0 0 132 141 313 357 641

216 92.5100 94.0000 0 0 0 0 0 0 0 133 142 207 336 644

217 94.0100 95.5000 0 0 0 0 0 0 0 133 142 208 337 612

218 95.5100 97.0000 0 0 0 0 0 0 0 133 142 208 338 614

219 97.0100 98.5000 0 0 0 0 0 0 0 134 143 209 339 616

220 98.5100 100.0000 0 0 0 0 0 0 0 134 143 210 340 618

221 100.0100 101.5000 0 0 0 0 0 0 0 121 129 273 319 585

222 101.5100 103.0000 0 0 0 0 0 0 0 122 130 274 320 587

223 103.0100 104.5000 0 0 0 0 0 0 0 122 130 275 321 589

224 104.5100 106.0000 0 0 0 0 0 0 0 122 130 276 322 556

401

T E C H

N I C A L D A T A

Wooden drums as per BDS -maximal length in meters

E L KA B E L

Page 403: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 403/430

402

T E C H N I C A L

D A T A

DESIGNATION CODE FOR POWER CABLESaccording to DIN VDE 0271/0276

E L KA B E L

Construction reference x

Identification of DesignationN DIN VDE standard(N) similar to DIN VDE standard

- IEC 502

Conductor Material A aluminium conductor- copper conductor

Insulating Materials Y PVC2X cross-linked PE (XLPE)

Concentric conductor (screen)C concentric conductor of copperCE concentric conductor of copper over each individual coreS screen of copper wiresSE screen of copper wires over each individual coreH conductive layers

(F) longitudinally water-proof screen(FL) longitudinally and radial water-proof screen

ArmouringB steel tape armouringR armour of galvanized round steel wires

Sheath Material Y PVC2Y PEH halogen-free thermoplastic polymer

Protective ConductorI with protective conductorO without protective conductor

Number of Cores

Conductor Cross Section in mm2

Conductor Typer... circular conductor .. m stranded conductors... sector conductor /V compact conductor..e... circular, solid conductor

Rating Voltage0.6/1 kV3.6/6 kV6.0/10 kV12/20 kV18/30 kV

Examples:

NYY-J 4x1.5 RE 0.6/1 kV - VDE 0276-603

Cable according to standard, PVC-insulated, sheath PVC, with green-yellow marked core, 4 cores with nominal cross-section 1.5 mm2,

circular conductor, solid, rating voltage 0.6/1 kV.

A2XS2Y 1x35 RM/16 6/10 kV - IEC 60502-2

Single core XLPE-insulated cable with PE-sheath according to standard, circular, stranded aluminium conductor with nominal cross-sec-

tion 35 mm2, covered with copper-screen 16 mm2 and rating vpltage (Uo/U) 6/10 kV.

Page 404: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 404/430

403

T E C H

N I C A L D A T A

Current Carrying Capacity and Indicationsfor Calculation of Power Cables and Wires

E L KA B E L

The guidelines for current carrying capacities of copper and aluminium are valid DIN VDE 0298 part 4 as well as DIN VDE0276 part 603 and for the conversion factors DIN VDE 0276 part 1000.

The current carrying capacity of a cable should be limited in such a degree that all locations in a cable system whichcauses the generated heats under given proportions to lead safely in the environment.

The heat flow depends on the inner heat-resistance between conductor and outer surface of the cable and as well asfrom the heat emission to the surroundings.

The following recommended values are the current carrying capacity of cables for laying in earth and in air at normaloperating conditions. Hints for the deviated operating conditions, see DIN VDE 0298 table 4 and DIN VDE 0276 part 603and part 1000.

Indications for Calculation

For Laying in Earth

− Deviating operating conditions with both conversion factors are to be considered, as these depend on both of specific heat resistance

and the grade of load.

− EVU-load (load grade) is the maximum load factor of 0.7. The conversion factors for the load grades 0.5, 0.6, 0.85 and 1.0 are to be

taken in tables DIN VDE 0276 part 603 and part 1000. Intermediate values can be interpolate (1.0 used for permanent load).

− Laying depth 0.7 m. The load capacity decreases with increasing of the laying depth. Usual depth of laying is 0.7 to 1.2 m.

− As normal value of the specific ground thermal resistivity in moist areas is selected with 1.0 K.m/W. For dry areas the chosen value is

2.5 K.m/W, under consideration of the applied usual bedding materials of sands.

− For favourable ground conditions or with thermal resisted bedding materials, lower value under well consolidation can be achieved.

For individual case, the values and upon that the resulted current carrying loads are to be determined.

For Laying in Air

− The values stated in the tables for outdoor laying in the air are defined for permanent operation.

− The arrangement of the cables is corresponded the presentation in table 3, DIN VDE 0276 part 1000.

− Conversion factors for other laying conditions and the heaping of cables are shown in tables 10 and 11, DIN VDE 0276 part 1000.

− The current carrying capacities of multi-core cables can be calculated by using the current load value for 3-core cables according to

table 13 with help of the conversion factors.

− By using the cable channels of cable board underlays, etc., the air temperature will be increased. In this case the conversion factors

according to table 12 for deviating air temperature should be used.

− For outdoor installation in air, the ambient temperature is based on 30o

C.

Radiation of heats and solar influence must be taken into consideration, where a good air circulation is needed.

A sufficient large distance is to be retained between the cables and the heating elements, because badly insulated heating elements

often raise additionally the temperature of the cable.

Distance between the cable and the wall, floor or ceiling = 2 cm

Distance between the cables being laid one above the other = 2 x D

Distance between the cable systems being laid one above the other = 20 cm

Distance between the cables being laid side by side = 2 x D

Specific Ground Thermal Resistivity- very moist area = 0.7 K.m/W

- moist area = 1.0 K.m/W

- dry area = 2.0 K.m/W

- very dry area = 3.0 K.m/W

Page 405: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 405/430

404

T E C H N I C A L

D A T A

INSTALLATION METHODS AND OPERATING CONDITIONS- Power Cables and Insulated Wires for Fixed Installation

E L KA B E L

Installation method type A1

Single core cables in insulation tube in a thermally insulated wall.

Installation method A2

Multicore cables or multicore plastic sheathed cables in the insulation tube in a thermally insulated wall, whereby the

walls for the methods of installation employed comprise an outer weatherproof board, thermal insulation and an inner

board of wood or materials similar to wood, having a temperature lag of 0.1 m2

.K/W. The plastic or metal insulation

tube is mounted so that it is very close to the inner wall without actually being in conduct with the wall.

Installation method B1

Single core cables in insulation tube on a wooden wall.

Installation method B2

Multicore cables or multicore plastic sheath cables in insulation tube on a wooden wall.

For both installation methods, the insulation tube must be secured so that the space between conduit and the wall sur-face is less than 0.3 times the diameter of the insulation tube. The plastic or metal insulation tube can be installed

directly on the masonry construction or plastered surface, whereby the current carrying capacity of the cables or wires

can then be higher. This problem is still being investigated by CENELEC.

Installation method C

Single core or multicore cables, or single core or multicore plastic-sheathed cables on a wooden wall.

The cables or insulated wires shall be mounted so that the space from the wall surface is less than 0.3 times the outer

diameter of the cable or insulated wire. The current carrying capacity can be increased when installed directly on or in

the masonry construction as well as underneath the plaster.

Installation methods E, F and G

Single core or multicore cables, or single core or multicore plastic-sheathed cables, installed in the open air.The cable or insulated wire shall be installed so that the dissipation of heat is not impeded, whereby allowance shall

be made for heating by other sources and for irradiation by sunshine. Natural convection shall not be obstructed. The

space from the cable or insulated wire by each bordering surface shall be 0.3 times the outside diameter. A space

equal to the one of the outside diameter is sufficient for single core cables and plastic-sheathed wires in order to meet

the current carrying requirements for an installation in the open air.

Page 406: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 406/430

405

T E C H

N I C A L D A T A

Laying Conditions for Power Cables

E L KA B E L

As laying depth, the mathematical distance to the cable axis - for triangular bunched laying, the distance of the bundle

axis to the earth surface of 70 cm is chosen. With increased laying depth the load ratings will be mathematically reduced.

Hereby the same temperature and the same thermal earth resistances are to be presumed.

Normal operation conditions and indications for deviating operation conditions.

Normal Operation Conditions

Laid in Earth Laid in Air Indications

1 Multicore cable 1 Multicore cable Conversion factors see thefollowing tables

1 Single core cable 1 Single core cable as of collective layingin direct current- in direct current- conditions see the followingsystem system tables

3 Single core cables 3 Single core cablesin 3-phase system, in 3-phase system,side by side, with a side by side, with aspace of 7 cm space of a cable ∅

3 Single core cables 3 Single core cablesin 3-phase system, in 3-phase system,in bundle form1) in bundle form 1)

Bedding in sand or - Laid in open air, i.e. unhin-earth shove and if dered heat radiation will be Conversion factors fornecessary covering ensured at: laying in earth:with bricks, cement Distance of cable from wall, - covering hood with airplates or with flat floor or ceiling ≥ 2 cm cavity = 0.9to light curved thin laid in conduit = 0.85covering of plastic - For cables laying side by side:

Space at least two times of Conversion factors for Ambient Conditions the cable ∅ laying in air:- Ground temperature at - alternating ambientinstallation depth: 20 oC - For cables laying one above temperatures- Soil-thermal resistivity the other: - as of collecting layingof moist area: 1.0 K.m/W Vertical space of the cable at conditions- Soil-thermal resistivity least two times of the cable ∅ - for laying in conduitsof dry area: 2.5 K.m/W cable length at least 30 cm - see tables and indications

according to DIN VDE 0298Connecting and earthing of metal - Consideration of thermal losssheaths or screens on both ends in cable, the incresed air temperature

of sufficient big and ventilated rooms

- Protection against direct heatradiation of sunlight, etc.

- Air temperature 30 oC

Adequate big or ventilated rooms,due to that the power loss of thecable not be noticeable increased

Connecting and earthing ofmetal sheaths or screens on both

sides

1)In "bunched" or triangle touching arrangement.

7 cm d d

Page 407: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 407/430

406

T E C H N I C A L

D A T A

Current ratings for installation A1, A2, B1 and B2Cables for fixed installation within buildings

E L KA B E L

Operating temperature at conductor 70 oC; Ambient temperature 30 oC

Type designation H07V-U, -R, -K NYM, NYBUY H07V-U, -R, -K NYM, NYBUYH07V3-U, -R, -K N05VV-U, N05VV-R H07V3-U, -R, -K N05VV-U, N05VV-R

NHXMH NHXMH

NYY, NYCY

1)

NYY, NYCY

1)

Installation: Single core cables Multicore sheathed Single core cables Multicore cables or* in thermally in insulating tubes, cables in insulating in insulating tubes multicore sheathedinsulated walls in a thermally insulated tubes, in a thermally on a wall cables in insulating* in insulating tubes walls insulated walls tubes on a wall

Installation in thermally insulated walls Installation in insulating tubes

Installation method 2) A1 A2 B1 B2Number of loaded cores 2 3 2 3 2 3 2 3

Cross-section, mm2 Current ratings in Ampere (A)

1.5 15.5 3) 13.5 15.5 13.0 17.5 15.5 16.5 15.02.5 19.5 18.0 18.5 17.5 24 21 23 204 26 24 25 23 32 28 30 276 34 31 32 29 41 36 38 3410 46 42 43 39 57 50 52 4610 - - - - - - - 47.17 4)

16 61 56 57 52 76 68 69 6225 80 73 75 68 101 89 90 8035 99 89 92 83 125 110 111 9950 119 108 110 99 151 134 133 11870 151 136 139 125 192 171 168 14995 182 164 167 150 232 207 201 179120 210 188 192 172 269 239 232 206150 240 216 219 196 - - - -185 273 245 248 223 - - - -240 320 286 291 261 - - - -300 367 328 334 298 - - - -

Conversion factors for deviating ambient temperature. grouping. installation under the ceiling. multicore cables and insulated wires - see DIN VDE 0298 part 4.1) The current ratings are valid for cables with concentric conductor. only for versions.2) For further installation methods - see DIN VDE 0298 part 4.3) See DIN VDE 0298 part 4.4) Not permitted for the installation on a wooden wall and not for application of the conversion factors. see DIN VDE 0298 part 4.

Page 408: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 408/430

Operating temperature at conductor 70oC; Ambient temperature 30o C

Type designation NYM, NYIF, NYIFY, NYBUY, N05W-U, NYYN05W-R, NHXMH, NYY, NYCY 1)

Installation: Singlecore or multicore Multicore cables or Single core cables or single core sheathed cables* directly cables or single multicore sheathed with a space of minimum 1x diameter d to wall;* in open air or multicore sheathed cables with a space of

cables on a wall minimum 0,3xdiameter d to wall with contact with gap d

direct installation installation in open air

Installation method 2) C E F GNumber of loaded 2 3 2 3 2 3Cross-section, mm2 Current ratings in Ampere (A)

1.5 19.5 17.5 22 18.5 - - - - -2.5 27 24 30 25 - - - - -4 36 32 40 34 - - - - -4 - 33.02 3) - - - - - - -6 46 41 51 43 - - - - -

10 63 57 70 60 - - - - -10 - 59.43 3) - - - - - - -16 85 76 94 80 - - - - -25 112 96 119 101 131 114 110 146 13035 138 119 148 126 162 143 137 181 16250 168 144 180 153 196 174 167 219 19770 213 184 232 196 251 225 216 281 25495 258 223 282 238 304 275 264 341 311

120 299 259 328 276 352 321 308 396 362150 344 299 379 319 406 372 356 456 419185 392 341 434 364 463 427 409 521 480240 461 403 514 430 546 507 485 615 569300 530 464 593 497 629 587 561 709 659400 - - - - 754 689 656 852 795500 - - - - 868 789 749 982 920630 - - - - 1005 905 855 1138 1070

Conversion factors for deviating ambient temperature. grouping. installation under the ceiling. multicore cables and insulated wires - see DIN VDE 0298 part 4.

1) The current ratings are valid for cables with concentric conductor. only for multicore versions.2) For further installation method - see DIN VDE 0298 part 4.3) See DIN VDE 0298 part 4.

or

or

≥0,3d ≥d ≥d ≥d ≥d

≥d≥d

407

T E C H

N I C A L D A T A

Current ratings for installation conditions C, E, F and G

Cables for fixed installation within buildings

E L KA B E L

Page 409: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 409/430

Operating temperature at Conductor 90 oC; Ambient temperature 30 oC

Type designation H07V2-U, -K N12XY, N2XY, , NHXHX H07V2-U, -K N12XY, N2XY, N2X2YH07Z-U, -R, -K N2X2Y, N2XH, N2XCH H07Z-U, -R, -K N2XH, N2XCH FE180

FE180 NHXCHX NHXHX FE180 NHXCHX

FE180 NHXH NHXH FE180 NHXCH FE180FE180 NHXCH FE180 NHXHX, NHXCHXNHXHX, NHXCHX

Installation: Single core cables, Multicore sheathed Single core cables Multicore cables* in thermally in insulating tubes cables in insulating tubes, in insulating tubes or multicore sheathedinsulated walls in a thermally insulated in a thermally insulated on a wall cables in insulating* in insulating tubes walls walls tubes on a wall

Installation in thermally insulated walls Installation in insulating tubes

Installation method 1) A1 A2 B1 B2Number of loaded cores 2 3 2 3 2 3 2 3

Cross-section, mm2

Current ratings in Ampere (A)

1.5 19.0 17.0 18.5 16.5 23 20 22 19.52.5 26 23 25 22 31 28 30 264 35 31 33 30 42 37 40 356 45 40 42 38 54 48 51 44

10 61 54 57 51 75 66 69 6016 81 73 76 68 100 88 91 8025 106 95 99 89 133 117 119 10535 131 117 121 109 164 144 146 12850 158 141 145 130 198 175 175 15470 200 179 183 164 253 222 221 19495 241 216 220 197 306 269 265 233

120 278 249 253 227 354 312 305 268150 318 285 290 259 - - - -185 362 324 329 295 - - - -240 424 380 386 346 - - - -

300 486 435 442 396 - - - -

Conversion factors for deviating ambient temperature, grouping, installation under the ceiling, multucore cables and insulated wires - see DIN VDE 0298 part 4.1) For further installation conditions - see DIN VDE 0298 part 4.

408

T E C H N I C A L

D A T A

Current ratings for installation conditionsCables for fixed installation within buildings A1, A2, B1 and B2

E L KA B E L

Page 410: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 410/430

Operating temperature at conductor 90 oC; Ambient temperature 30 oC

Type designation N12XY, N2XY, N2X2Y N12XY, N2XY, N2X2YN2XH, N2XCH 1), NHXHX FE180 N2XH NHXH FE180NHXH FE180, NHXCH FE180 1)

NHXHX FE180, NHXCHX FE1801)

NHXHX, NHXCHX 1) NHXHX

Installation: Single core or multicore Multicore cables or Single core cables or single core* directly cables or single or multicore sheathed cables sheathed cables with a space* in open air multicore sheathed with a space of minimum of minimum 1x diameter d to wall

cables on a wall 0,3x diameter d to wall with contact with gap d

direct installation installation in open air

Installation method 2) C E F GNumber of l 2 3 2 3 2 3Loaded cores

Cross-section, mm2 Current ratings in Ampere (A)

1.5 24 22 26 23 - - - - -

2.5 33 30 36 32 - - - - -4 45 40 49 42 - - - - -6 58 52 63 54 - - - - -

10 80 71 86 75 - - - - -16 107 96 115 110 - - - - -25 138 119 149 127 161 141 135 182 16135 171 147 185 158 200 176 169 226 20150 209 179 225 192 242 216 207 275 24670 269 229 289 246 310 279 268 353 31895 328 278 352 298 377 342 328 430 389

120 382 322 410 346 437 400 383 500 454150 441 371 473 399 504 464 444 577 527185 506 424 542 456 575 533 510 661 605240 599 500 641 538 679 634 607 781 719300 693 576 741 621 783 736 703 902 833400 - - - - 940 868 823 1085 1008500 - - - - 1083 998 946 1253 1169

630 - - - - 1254 1151 1088 1454 1362

Conversion factors for deviating ambient temperature, grouping, installation under the ceiling, multicore cables and insulated wires - see DIN VDE 0298 part 4.1) The current ratings are valid for cables with concentric conductor, only for multicore versions.2) For further installation methods - see DIN VDE 0298 part 4.

or

or

≥0,3d ≥d ≥d ≥d ≥d

≥d≥d

409

T E C H

N I C A L D A T A

Current ratings for installation conditions C, E, F and GCables for fixed installation within buildings

E L KA B E L

Page 411: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 411/430

Current carrying capacity in Ampere (A), laying in ground (20 oC)

Nominal Copper conductor Aluminium conductorcross-section NYY NYCY NAYY NAYCY

mm2

1.5 30 27 41 31 27 - - - - -2.5 39 36 55 40 36 - - - - -4 50 47 71 51 47 - - - - -6 62 59 90 63 59 - - - - -

10 83 79 124 84 79 - - - - -16 107 102 160 108 102 - - - - -25 138 133 208 139 133 106 102 160 108 10335 164 159 250 166 160 127 123 193 129 12350 195 188 296 196 190 151 144 230 153 14570 238 232 365 238 234 185 179 283 187 18095 286 280 438 281 280 222 215 340 223 216

120 325 318 501 315 319 253 245 389 252 246150 365 359 563 347 357 284 275 436 280 276185 413 406 639 385 402 322 313 496 314 313240 479 473 746 432 463 375 364 578 358 362300 541 535 848 473 518 425 419 656 397 415

400 614 613 975 521 579 487 484 756 441 474500 693 687 1125 574 624 558 553 873 489 528

1) Rated current for direct current systems with a far-distanced return conductor

Current carrying capacity in Ampere (A), laying in air (30 oC)

Nominal Copper conductor Aluminium conductorcross-section NYY NYCY NAYY NAYCY

mm2

1.5 21 19.5 27 22 19,5 - - - - -2.5 28 25 35 29 26 - - - - -4 37 34 47 39 34 - - - - -6 47 43 59 49 44 - - - - -

10 64 59 81 67 60 - - - - -16 84 79 107 89 80 - - - - -25 114 106 144 119 108 87 82 110 91 8335 139 129 176 146 132 107 100 135 112 10150 169 157 214 177 160 131 119 166 137 12170 213 199 270 221 202 166 152 210 173 15595 264 246 334 270 249 205 186 259 212 189

120 307 285 389 310 289 239 216 302 247 220150 352 326 446 350 329 273 246 345 280 249185 406 374 516 399 377 317 285 401 321 287240 483 445 618 462 443 378 338 479 374 339300 557 511 717 519 504 437 400 555 426 401400 646 597 843 583 577 513 472 653 488 468500 747 669 994 657 626 600 539 772 556 524

1) Rated current for direct systems with a far-distanced return conductor

Conversion factors for multicore cable (≥ 5 cores)The conversion factors are to be used for laying the cables in ground or in air, to the values given in above tables.

Number of loaded cores n Laying in ground f Laying in air f

5 0.70 0.757 0.60 0.65

10 0.50 0.5514 0.45 0.5019 0.40 0.4524 0.35 0.4040 0.30 0.3561 0.25 0.30

Note: Valid for cross-section 1,5 to 10 mm 2 .

1) 1)

1) 1)

410

T E C H N I C A L

D A T A

Current ratings for NYY, NAYY, NYCY, NAYCY 0,6/1 kV

E L KA B E L

Page 412: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 412/430

Nominal Copper conductor Aluminium conductor

cross- N2XY; N2X2Y N2XCY; N2XC2Y NA2XY; NA2X2Y NA2XCY; NA2XC2Y

section mm2

1,5 48 31 33 31 33 - - - - -2,5 63 40 42 40 43 - - - - -4 82 52 54 52 55 - - - -6 102 64 67 65 68 - - - - -10 136 86 89 87 91 - - - - -16 176 112 115 113 117 - - - - -25 229 145 148 146 150 177 112 114 113 11635 275 174 177 176 179 212 135 136 136 13850 326 206 209 208 211 252 158 162 159 16470 400 254 256 256 257 310 196 199 197 20195 480 305 307 307 304 372 234 238 236 240120 548 348 349 349 341 425 268 272 269 272150 616 392 393 391 377 476 300 305 302 303185 698 444 445 442 418 541 342 347 342 340240 815 517 517 509 469 631 398 404 397 387300 927 585 583 569 514 716 457 457 454 430

400 1064 671 663 637 565 825 529 525 520 479500 1227 758 749 691 623 952 609 601 584 531

1) 1)

1) Rated current for direct current systems witn a far-distanced retum conductor.

411

T E C H

N I C A L D A T A

Current ratings for N2XY, NA2XY; N2XCY; NA2XCY; N2X2Y;NA2X2Y; N2XC2Y, NA2XC2Y; N2XH, NA2XH; N2XCH; NA2XCH

Current carrying capacity in Ampere (A), laying in ground (20 oC)

E L KA B E L

Page 413: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 413/430

Cross-section Insulation - PVC Insulation - XLPEConductor temperature: 70 oC Conductor temperature: 90 oCShort-circuit temperature: 160 oC Short-circuit temperature: 250 oC

Short-circuit time: 1 s Short-circuit time: 1 s

mm2 with Cu-conductors with Al-conductors with Cu-conductors with Al-conductors

1.5 0.17 - 0.21 -2.5 0.29 - 0.36 -

4 0.46 - 0.57 -6 0.69 - 0.86 -

10 1.15 - 1.43 -

16 1.84 - 2.29 -25 2.88 1.90 3.57 2.3535 4.03 2.66 5.01 3.2950 5.75 3.80 7.15 4.7070 8.05 5.32 10.01 6.5895 10.93 7.22 13.59 8.93

120 13.80 9.12 17.16 11.28150 17.25 11.40 21.45 14.10185 21.27 14.06 26.46 17.39240 27.60 18.24 34.32 22.56300 30.90 20.40 42.90 28.20400 41.20 27.20 57.20 37.60500 51.50 34.00 71.50 47.00

Short-circuit current carrying capacity up to 0,6/1kV

Electrical characteristics of PVC and XLPE insulated Low

Voltage Power Cables, 0,6/1kV

412

T E C H N I C A L

D A T A

Current carrying capacity in Ampere (A)laying on air (30 oC)

E L KA B E L

Nominal Copper conductor Aluminium conductor

Cross- N2XY; N2X2Y; N2XH N2XCY; N2XC2Y; NA2XY; NA2X2Y; NA2XH NA2XCY

section mm2 N2XCH NA2XC2Y; NA2XCH

1,5 33 24 26 25 27 - - - - -

2,5 43 32 34 33 36 - - - - -

4 57 42 44 43 47 - - - - -

6 72 53 56 54 59 - - - - -

10 99 74 77 75 81 - - - - -

16 131 98 102 100 109 - - - - -

25 177 133 138 136 146 136 102 106 104 112

35 217 162 170 165 179 166 126 130 128 137

50 265 197 207 201 218 205 149 161 152 169

70 336 250 263 255 275 260 191 204 194 214

95 415 308 325 314 336 321 234 252 239 263

120 485 359 380 364 388 376 273 295 278 308

150 557 412 437 416 438 431 311 339 316 349

185 646 475 507 480 501 501 360 395 365 401

240 774 564 604 565 580 600 427 472 430 469300 901 649 697 643 654 696 507 547 506 535

400 1060 761 811 737 733 821 600 643 575 615

500 1252 866 940 807 825 971 695 754 682 700

1)

1) Rated current for direct systems with a far-distanced return conductor.

Page 414: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 414/430

413

T E C H

N I C A L D A T A

Current ratings - Conversion factorsfor grouping of single core cables or cables on troughs and trays

E L KA B E L

Number of three-phase systems Used as multiplier Number of 1 2 3 with single core cables for ratings value for troughs or trays Conversion factors

Installation method

Perforated cable troughs with contact Three-cores cable 1 0,98 0,91 0,87in horizontal-surfacearrangement 2 0,96 0,87 0,81

3 0,95 0,85 0,78

with contact Three-cores cablet 1 0,96 0,86 -vertical-surface 2 0,95 0,84 -arrangemen

Cable trays with contactThree-cores cablein horizontale surfacearrangement 1 11,00 0,97 0,96

` 2 0,98 0,93 0,89

3 0,97 0,90 0,86

Perforated cable troughs 1 1,00 0,98 0,96

2 0,97 0,93 0,89

3 0,96 0,92 0,86

Three-core cablesin vertical-surface 1 1,00 0,91 0,89triangle arrangement 2 1,00 0,90 0,86

Cable trays 1 1,00 1,00 1,00

2 0,97 0,95 0,93

3 0,96 0,94 0,90

Note: The conversion factors are used only for cables of one layer grouping arrangement. These are not valied when the cables are installed with contact one upon another or the given sprees between the cable toughs or cable trays, are not followed, in such cases the conversion fac- tors can be reduced. To parallel current circuits each group of three conductors of the parallel circuit is regarded as single circuit.

≥ 300 mm

≥ 20 mm

≥ 225 mm

≥ 300 mm

≥ 300 mm

≥ 300 mm

≥ 20 mm

≥ 20 mm

≥ 2d

≥ 225 mm

≥ 20 mm

≥ 2d

d

≥ 2d

d

d

Page 415: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 415/430

414

T E C H N I C A L

D A T A

Current ratings - conversion factorsfor grouping of multicore cables or cables on troughs and trays

E L KA B E L

Number of multicore cables 1 2 3 4 6 9

Installation method Number of troughs Conversion factors

or trays

Non-perforated cable with contact 1 0,97 0,84 0,78 0,75 0,71 0,68

troughs 2 0,97 0,83 0,76 0,72 0,68 0,63

3 0,97 0,82 0,75 0,71 0,66 0,61

6 0,97 0,81 0,73 0,69 0,63 0,58

Perforated cable troughs with contact 1 1,00 0,88 0,82 0,79 0,76 0,73

2 1,00 0,87 0,80 0,77 0,73 0,68

3 1,00 0,86 0,79 0,76 0,71 0,66

6 1,00 0,84 0,77 0,73 0,68 0,64

with space 1 1,00 1,00 0,98 0,95 0,91 -

2 1,00 0,99 0,96 0,92 0,87 -

3 1,00 0,98 0,95 0,91 0,85 -

with contact 1 1,00 0,88 0,82 0,78 0,73 0,72

2 1,00 0,88 0,81 0,76 0,71 0,70

with space 1 1,00 0,91 0,89 0,88 0,87 -

2 1,00 0,91 0,88 0,87 0,85 -

Cable trays with contact 1 1,00 0,87 0,82 0,80 0,79 0,78

2 1,00 0,86 0,81 0,78 0,76 0,73

3 1,00 0,85 0,79 0,76 0,73 0,70

6 1,00 0,83 0,76 0,73 0,69 0,66

with space 1 1,00 1,00 1,00 1,00 1,00

- 2 1,00 0,99 0,98 0,97 0,9

3 1,00 0,98 0,97 0,96 0,93 -

Note: The conversion factor are used for cables of one layer grouping arrangement. These are not valid when the cables are installed with con-

tact one upon another or the given spaces between the cable troughs or cable trays can not meet in such cases the conversion factor can be

reduced.

≥20 mm

≥ 3 0 0 m m

≥20 mm

≥ 3 0 0 m m

≥20 mm

≥ 3 0 0 m m

≥20 mm

≥ 3 0 0 m m

≥20 mm

≥ 3 0 0 m m

≥225 mm

≥225 mm

d

d

Page 416: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 416/430

Current carrying capacity in Amperes (A) in ground (20 oC)

Conductor Copper conductor Aluminium conductormaterial

Arrangement

U0/U 6/10 kV 12/20 kV 18/30 kV 6/10 kV 12/20 kV 18/30 kVcross- Current ratings in Ampere (A)section mm2

25 157 179 - - - - - - - - - -35 187 212 189 213 - - 145 165 - - - -50 220 249 222 250 225 251 171 194 172 195 174 19570 268 302 271 303 274 304 208 236 210 237 213 23895 320 359 323 360 327 362 248 281 251 282 254 283120 363 405 367 407 371 409 283 318 285 319 289 321150 405 442 409 445 414 449 315 350 319 352 322 354185 456 493 461 498 466 502 357 394 361 396 364 399240 526 563 532 568 539 574 413 452 417 455 422 458300 591 626 599 633 606 640 466 506 471 510 476 514400 662 675 671 685 680 695 529 558 535 564 541 570500 744 748 754 760 765 773 602 627 609 634 616 642

This factors are also valid for longitudinally water-tight cable

Current carrying capacity* in Amperes (A) in air (30 oC)

Conductor Copper conductor Aluminium conductormaterial Arrangement

U0/U 6/10 kV 12/20 kV 18/30 kV 6/10 kV 12/20 kV 18/30 kVcross-section

mm2 Current ratings in Ampere (A)

25 163 194 - - - - - - - - - -35 197 235 200 235 - - 153 182 - - - -50 236 282 239 282 241 282 183 219 185 219 187 21970 294 350 297 351 299 350 228 273 231 273 232 27395 358 426 361 426 363 425 278 333 280 332 282 331120 413 491 416 491 418 488 321 384 323 384 325 382150 468 549 470 549 472 548 364 432 366 432 367 429185 535 625 538 625 539 624 418 496 420 494 421 492240 631 731 634 731 635 728 494 583 496 581 496 578300 722 831 724 830 725 828 568 666 569 663 568 659400 827 920 829 923 831 922 660 755 660 753 650 750500 949 1043 953 1045 953 1045 767 868 766 866 764 861

* This factors are also valid for longitudinally water-tight cable

415

T E C H

N I C A L D A T A

E L KA B E L

Power ratings for XLPE-insulatedMedium Voltage Power Cables 6/10 kV, 12/20 kV, 18/30 kV

N2XSY NA2XSY N2XS2Y NA2XS2Y N2XS(F)2Y NA2XS(F)2Y

Page 417: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 417/430

Conductor resistance 20 oC

maximum valuecross-section Cu-conductor Alu-conductor

mm2 Ohm/km Ohm/km

25 0.727 1.2035 0.524 0.86850 0.387 0.64170 0.268 0.44395 0.193 0.320

120 0.153 0.253150 0.124 0.206185 0.0991 0.164240 0.0754 0.125300 0.0601 0.100400 0.0470 0.0778500 0.0366 0.0605

Conversion factors for the conductor temperatures

Temperature at oC 60 65 70 80 90Cu-conductor 1.157 1.177 1.196 1.236 1.275 Alu-conductor 1.161 1.181 1.202 1.242 1.282

Conversion formula:

Rδ= R20 . 234.5 + δfor Cu-conductor

254.5

Rδ = R20 . 228 + δ for Alu-conductor248

Conductor temperature at oC = δConductor resistance at δ C in Ohm/km = Rδ

Conductor resistance at 20 oC in Ohm/km = R20

416

T E C H N I C A L

D A T A

Electrical characteristics of XLPE-insulatedMedium Voltage Power Cables, 6 - 30 kV

E L KA B E L

Page 418: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 418/430

417

T E C H

N I C A L D A T A

Electrical characteristics of XLPE-insulatedMedium Voltage Power Cables, 6 - 30 kV

E L KA B E L

Effective resistance at 50 Hz (Alternating-current resistance)

Copper conductorNominal voltage 6/10 kV 12/20 kV 18/30 kV

Cross-section 0hm/kmmm2

35 0.671 0.673 0.671 0.672 - -50 0.497 0.498 0.496 0.498 0.496 0.49770 0.345 0.346 0.345 0.346 0.344 0.34695 0.249 0.251 0.249 0.250 0.249 0.250120 0.198 0.200 0.198 0.200 0.198 0.199150 0.163 0.165 0.163 0.165 0.162 0.164185 0.132 0.134 0.131 0.133 0.131 0.133240 0.102 0.104 0.101 0.103 0.101 0.103300 0.082 0.085 0.082 0.084 0.082 0.084400 0.068 0.071 0.067 0.070 0.067 0.069500 0.055 0.058 0.055 0.058 0.054 0.057

Aluminium conductor

Nominal voltage 6/10 kV 12/20 kV 18/30 kVCross-section 0hm/kmmm2

35 1.12 1.12 1.12 1.12 - -50 0.825 0.826 0.825 0.826 0.824 0.82670 0.571 0.572 0.571 0.572 0.571 0.57295 0.413 0.415 0.413 0.414 0.413 0.414120 0.327 0.329 0.327 0.329 0.327 0.328150 0.269 0.271 0.268 0.270 0.268 0.270185 0.215 0.217 0.215 0.217 0.214 0.216240 0.165 0.167 0.165 0.167 0.164 0.166300 0.133 0.135 0.133 0.135 0.133 0.135400 0.106 0.109 0.106 0.109 0.106 0.108500 0.085 0.088 0.084 0.087 0.084 0.087

Inductive resistance at 50 Hz

Nominal voltage 6/10 kV 12/20 kV 18/30 kVCross-section 0hm/kmmm2

35 0.144 0.158 0.153 0.168 - -50 0.136 0.150 0.145 0.159 0.154 0.16970 0.129 0.143 0.138 0.152 0.147 0.16195 0.123 0.137 0.131 0.145 0.139 0.154120 0.118 0.132 0.126 0.140 0.134 0.148150 0.114 0.128 0.121 0.135 0.129 0.143185 0.110 0.124 0.117 0.131 0.125 0.139240 0.105 0.120 0.112 0.126 0.120 0.134300 0.102 0.116 0.108 0.123 0.115 0.130

400 0.097 0.111 0.103 0.117 0.110 0.124500 0.094 0.108 0.100 0.114 0.106 0.120

Page 419: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 419/430

Mutual capacitance

Nominal voltage 6/10 kV 12/20 kV 18/30 kVCross-section

mm2 µF/km µF/km µF/km

35 0,22 0,16 -50 0,25 0,18 0,1470 0,28 0,20 0,1595 0,31 0,22 0,17

120 0,23 0,23 0,23150 0,37 0,25 0,19185 0,40 0,27 0,20240 0,44 0,30 0,22300 0,48 0,32 0,24400 0,55 0,36 0,27500 0,60 0,40 0,29

InductanceNominal voltage 6/10 kV 12/20 kV 18/30 kV

Cross-sectionmm2 mH/km mH/km mH/km mH/km mH/km mH/km

35 0,45 0,76 0,48 0,76 - -50 0,42 0,73 0,45 0,74 0,48 0,7570 0,39 0,70 0,43 0,70 0,45 0,7195 0,38 0,67 0,41 0,68 0,43 0,68

120 0,36 0,65 0,39 0,65 0,42 0,66150 0,35 0,63 0,38 0,63 0,41 0,64185 0,34 0,61 0,36 0,62 0,39 0,63240 0,32 0,59 0,35 0,59 0,37 0,60300 0,31 0,57 0,33 0,58 0,36 0,59400 0,30 0,55 0,33 0,55 0,34 0,56500 0,29 0,53 0,31 0,53 0,33 0,54

418

T E C H N I C A L

D A T A

Electrical characteristics of XLPE-insulatedMedium Voltage Power Cables, 6 - 30 kV

E L KA B E L

Page 420: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 420/430

Short-circuit current carrying capacity up to 30 kVConductor temperature: 90 oCShort-circuit temperature: 250 oC

Cable with Cu-conductors

cross- short-circuit time in s (seconds)sectionmm2

0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,5 2,0 3,0 4,0 5,0

permissible short-circuit in kA

25 11,3 8,0 6,5 5,7 5,1 4,6 4,3 4,0 3,8 3,6 2,9 2,5 2,1 1,8 1,635 15,8 11,2 9,1 7,9 7,1 6,5 6,0 5,6 5,3 5,0 4,1 3,5 2,9 2,5 2,250 22,6 16,0 13,1 11,3 10,1 9,2 8,5 8,0 7,5 7,2 5,8 5,1 4,1 3,6 3,270 31,7 22,4 18,3 15,8 14,2 12,9 12,0 11,2 10,6 10,0 8,2 7,1 5,8 5,0 4,595 43,0 30,4 24,8 21,5 19,2 17,5 16,2 15,2 14,3 13,6 11,1 9,6 7,8 6,8 6,1

120 54,3 38,4 31,3 27,1 24,3 22,2 20,5 19,2 18,1 17,2 14,0 12,1 9,9 8,6 7,7150 67,8 48,0 39,2 33,9 30,3 27,7 25,6 24,0 22,6 21,5 17,5 15,2 12,4 10,7 9,6

185 83,7 59,2 48,3 41,8 37,4 34,2 31,6 29,6 27,9 26,5 21,6 18,7 15,3 13,2 11,8240 108,5 76,7 62,7 54,3 48,5 44,3 41,0 38,4 36,2 34,3 28,0 24,3 19,8 17,2 15,3300 135,7 95,9 78,3 67,8 60,7 55,4 51,3 48,0 45,2 42,9 35,0 30,3 24,8 21,5 19,2400 180,9 127,9 104,4 90,4 80,9 73,8 68,4 64,0 60,3 57,2 46,7 40,4 33,0 28,6 25,6500 226,1 159,9 130,5 113,1 101,1 92,3 85,5 79,9 75,4 71,5 58,4 50,6 41,3 35,8 32,0

Cable with Alu-conductors

cross-section

mm2

short-circuit time in s (seconds)

0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,5 2,0 3,0 4,0 5,0

permissible short-circuit in kA

25 7,4 5,3 4,3 3,7 3,3 3,0 2,8 2,6 2,5 2,4 1,9 1,7 1,4 1,2 1,135 10,4 7,4 6,0 5,2 4,7 4,2 3,9 3,7 3,5 3,3 2,7 2,3 1,9 1,6 1,550 14,9 10,5 8,6 7,4 6,6 6,1 5,6 5,3 5,0 4,7 3,8 3,3 2,7 2,4 2,170 20,8 14,7 12,0 10,4 9,3 8,5 7,9 7,4 6,9 6,6 5,4 4,7 3,8 3,3 2,995 28,2 20,0 16,3 14,1 12,6 11,5 10,7 10,0 9,4 8,9 7,3 6,3 5,2 4,5 4,0

120 35,7 25,2 20,6 17,8 16,0 14,6 13,5 12,6 11,9 11,3 9,2 8,0 6,5 5,6 5,0150 44,6 31,5 25,7 22,3 19,9 18,2 16,9 15,8 14,9 14,1 11,5 10,0 8,1 7,1 6,3185 55,0 38,9 31,7 27,5 24,6 22,5 20,8 19,4 18,3 17,4 14,2 12,3 10,0 8,7 7,8240 71,3 50,4 41,2 35,7 31,9 29,1 27,0 25,2 23,8 22,6 18,4 16,0 13,0 11,3 10,1300 89,2 63,1 51,5 44,6 39,9 36,4 33,7 31,5 29,7 28,2 23,0 19,9 16,3 14,1 12,6400 118,9 84,1 68,6 59,5 53,2 48,5 44,9 42,0 39,6 37,6 30,7 26,6 21,7 18,8 16,8

500 148,6 105,1 85,8 74,3 66,5 60,7 56,2 52,5 49,5 47,0 38,4 33,2 27,1 23,5 21,0

419

T E C H

N I C A L D A T A

Electrical characteristics of XLPE-insulatedMedium Voltage Power Cables, 6 - 30 kV

E L KA B E L

Page 421: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 421/430

Nominal voltage 6/10 kV 12/20 kV 18/30 kVcross-section mm2 A/km A/km A/km

35 1,2 1,7 -50 1,4 1,9 2,370 1,5 2,1 2,595 1,7 2,4 2,7120 1,9 2,6 2,9150 2,0 2,7 3,1185 2,2 3,0 3,3240 2,4 3,3 3,7300 2,6 3,5 4,0400 3,0 4,0 4,4500 3,3 4,3 4,8

Short-circuit time in seconds Load of short-circuit current in kA

bei 16 mm2 25 mm2 35 mm2

s kA kA kA

0,1 9,7 15,1 21,20,2 6,9 10,7 15,10,3 5,7 8,9 12,50,4 5,0 7,7 10,90,5 4,5 7,0 9,80,6 4,2 6,4 9,00,7 3,9 6,0 8,40,8 3,5 5,6 7,90,9 3,4 5,3 7,5

1,0 3,3 5,1 7,21,5 2,7 4,2 5,92,0 2,3 3,6 5,13,0 1,9 2,9 4,24,0 1,7 2,6 3,65,0 1,5 2,3 3,2

Short-circuit to ground

Short-cirguit current carrying capacity of copper screens

Short-circuit temperature: 350

o

C

Coordination of screen-cross-section

conductor cross-section mm2 screen-cross-section mm2

35 bis 120 16150 bis 300 25

400 und 500 35

420

T E C H N I C A L

D A T A

Electrical characteristics of XLPE-insulatedMedium Voltage Power Cables, 6 - 30 kV

E L KA B E L

Page 422: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 422/430

Load rating for cables laid in ground

Load factor 0,7 and 1,0

Fundamental conditions*

Ground temperature 20o

CThermal resistivity 1,0 K . m/W

Distance between cables or systems 7 cm

Single core cables laid in trefoil touching arrangement

Load factor 0,7

Type of Cable Nominal Number of cables or systems

insulation design voltage 2 4 6 8 10

PVC Multicore cables 0,6/1 bis 3,6/6 kV 0,86 0,71 0,64 0,60 0,57

Three core cables bis 6/10 kV 0,87 0,71 0,63 0,59 0,54

Single core cables 0,6/1 bis 3.6/6 kV 0,85 0.70 0,63 0,59 0,56

Single core cables bis 6/10 kV 0,83 0,66 0,57 0,53 0,49

VPE Multicore cables 0,6/1 bis 18/30 kV 0,85 0,70 0,63 0,59 0,56

Single core cables 0,6/1 bis 18/30 kV 0,85 0,70 0,63 0,58 0,56

Load factor 1,0

Type of Cable Nominal Number of cables or systems

insulation design voltage 1 2 4 6 8 10

PVC Mehradrige Kabel 0,6/1bis 3,6/6 kV 0,81 0,66 0,52 0,46 0,43 0,40

Dreiadride Kabel bis 6/10 kV 0,82 0,67 0,51 0,45 0,41 0,37

Einadrige Kabel 0,6/1 bis 3.6/6 kV 0,79 0,65 0.51 0,46 0,42 0,40

Einadrige Kabel bis 6/10 kV 0,78 0,62 0,47 0,40 0,36 0,33

VPE Mehradrige Kabel 0,6/1 bis 18/30 kV 0,83 0,67 0,53 0,47 0,44 0,41

Einadrige Kabel 0,6/1 bis 18/30 kV 0,81 0,66 0,52 0,47 0,43 0,41

Build-up of systems:

for single core cables 7 cm for multicore cables 7 cm

* Conversion factors for multicore cables (≥ 5 cores), Conductor cross-section from 1,5 to 10 mm2

Numbers of loaded cores Conversion factors for the values of 1,5 to 10 mm2

to the belonging table

Earth Air

5 0,7 0,757 0,6 0,6510 0,5 0,5514 0,45 0,519 0,4 0,4524 0,35 0,440 0,3 0,3561 0,25 0,3

* For other conditions e. g. ground, temperature grouping, load factor, thermal resistance, the rating factors should be calculated according to

DIN VDE 0276 part 1000.

421

T E C H

N I C A L D A T A

Conversion factor for

Medium Voltage Power Cables, 6 - 30 kV

E L KA B E L

Page 423: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 423/430

Rating conversion factors for laying in air*)

Multicore cable and single core dirrect current cable

Arrangement Number Without inter-contact With inter-contact

of cables cables Space = cable ∅ d contact with wallin laying troughs Distance from wall ≥ 2 cm

condition or trays

Number of cables Number of cables

Installation method 1 2 3 4 6 Installation method 1 2 3 4 6 9

on the

ground 1 0,97 0,96 0,94 0,93 0,90 0,97 0,85 0,78 0,75 0,71 0,68

on non-

perforated 1 0,97 0,96 0,94 0,93 0,90 0,97 0,85 0,78 0,75 0,71 0,68cable 2 0,97 0,95 0,92 0,90 0,86 0,97 0,84 0,76 0,73 0,68 0,63

troughs 3 0,97 0,94 0,91 0,89 0,84 0,97 0,83 0,75 0,72 0,66 0,61

(restricted 6 0,97 0,93 0,90 0,88 0,83 0,97 0,81 0,73 0,69 0,63 0,58

air circulation)

on perforated 1 1,00 1,00 0,98 0,95 0,90 1,00 0,88 0,82 0,79 0,76 0,73

cable troughs 2 1,00 0,99 0,96 0,92 0,87 1,00 0,87 0,80 0,77 0,73 0,68

3 1,00 0,98 0,95 0,91 0,85 1,00 0,86 0,79 0,76 0,71 0,66

6 1,00 0,97 0,94 0,90 0,84 1,00 0,84 0,77 0,73 0,68 0,64

on cable 1 1,00 1,00 1,00 1,00 1,00 1,00 0,87 0,82 0,80 0,79 0,78

trays or on 2 1,00 0,99 0,98 0,97 0,96 1,00 0,86 0,80 0,78 0,76 0,73

cable ladders 3 1,00 0,98 0,97 0,96 0,93 1,00 0,85 0,79 0,76 0,73 0,70

(unrestricted 6 1,00 0,97 0,96 0,94 0,91 1,00 0,83 0,76 0,73 0,69 0,66

air circulation)

on platform 1 1,00 0,91 0,89 0,88 0,87 1,00 0,88 0,82 0,78 0,73 0,72

or on wall or 2 1,00 0,91 0,88 0,87 0,85 1,00 0,88 0,81 0,76 0,71 0,70

on perforated

cable tray

laid on

platform or

on the wall 0,95 0,78 0,73 0,72 0,68 0,66

Arrangements, for which Number of cable Number of cable

a reduction arranged one over arraanged side-by-syde

not necessary1 another is optoinal is optoinal

1)In narrow rooms or for bigger grouping, the air temperature is increased due to energy losses of cable, so the additional conversion factors for deviating air-tempera-

tures are to be taken in the given table.

d d

a a

≥ 3 0 0 m m

a

d d

≥ 3 0 0 m m

a

a

2d 2d

≥ 3 0 0 m m

d

2 d

≥2 cm

d d

≥ 3 0 0 m m

a

≥ 3 0 0 m m

a

d

d

≥225 mm

≥225 mm

≥ 2 0 c m

≥2 cm

a ≥ 20 mm a ≥ 20 mm

a ≥ 20 mm a ≥ 20 mm

a ≥ 20 mm a ≥ 20 mm

a ≥ 20 mm a ≥ 20 mm

≥2d d

d d

≥ 3 0 0 m m

a

422

T E C H N I C A L

D A T A

Rating conversion factors for installation of Medium

Voltage Cables, 6 - 30 kV

E L KA B E L

Page 424: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 424/430

Rating conversion factors for laying in air*)

Single core cables in 3-phase systems

Arrangement Number of For laying on plain surface For installation in groupingof cables cables Space = cable ∅ d Space = 2x cable ∅ din laying troughs Distance from wall ≥ 2 cm Distance from wall ≥ 2 cmcondition or trays

on top Number of systems Number of systemsof each 1 2 3 1 2 3other

Installation method Installation method

on theground - a ≥ 20 mm 0,92 0,89 0,88 a ≥ 20 mm 0,98 0,96 0,94

on non-

perforated 1 0,92 0,89 0,88 0,98 0,96 0,94cable 2 0,87 0,84 0,83 0,95 0,91 0,87troughs 3 0,84 0,82 0,81 0,94 0,90 0,85(restricted 6 0,82 0,80 0,79 0,93 0,88 0,82air circulation)

a ≥ 20 mm a ≥ 20 mm

on perforatedcable troughs 1 1,00 0,93 0,90 1,00 0,98 0,96

2 0,97 0,89 0,85 0,97 0,93 0,893 0,96 0,88 0,82 0,96 0,92 0,856 0,94 0,85 0,80 0,95 0,90 0,83

a ≥ 20 mm a ≥ 20 mm

on cable 1 1,00 0,97 0,96 1,00 1,00 1,00trays or on 2 0,97 0,94 0,93 0,97 0,95 0,93cable ladders 3 0,96 0,93 0,92 0,96 0,94 0,90(unrestricted 6 0,94 0,91 0,90 0,95 0,93 0,87air circulation)

a ≥ 20 mm a ≥ 20 mm

on platform 1 0,94 0,91 0,89 1,00 0,91 0,89or on the wall 0,94 0,90 0,86 1,00 0,90 0,86

2

≥ 225 mm ≥ 225 mm

Arrangements, For the installation on plain surface withfor which greather distance, the muntual heating,a reduction is lower for this occur the additional sheathnot necessary 1) or screen-losses. Because of that no

particulars can be made forreduction-free arrangements.

* Conversion factors for deviating ambient temperature

TemperatureoC 10 15 20 25 30 35 40 45 50XLPE-cable 1,15 1,12 1,08 1,04 1,0 0,96 0,91 0,87 0,82PVC-cable 1,22 1,17 1,12 1,06 1,0 0,94 0,87 0,79 0,71

*1) In narrow rooms or for bigger grouping, the air temperature is increased due to energy losses of cable, so the additional conversion

factors for deviating air-temperatures are to be taken in the given table.

d d

a

d d

≥ 3 0 0 m

m

a

2d 2d

a

a

2d 2d

≥ 3 0 0 m m

a

2d 2d

≥ 3 0 0 m m

a

2d 2d

≥ 3 0 0 m m

2 d

d d

≥ 3 0 0 m m

a

d

d

d d

≥ 3 0 0 m m

a

423

T E C H

N I C A L D A T A

Rating conversion factors for installationof Medium Voltage Cables, 6 -30 kV

E L KA B E L

Page 425: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 425/430

424

T E C H N I C A L

D A T A

Designation Code for Harmonized Cables According to DIN VDE 0281/DIN VDE 0292

E L KA B E L

Construction reference H 05 V V5 - F 25 G 0.75

Identifications of Designation A Authorized national standardsH Harmonized standards

Nominal Voltage U01 100 V03 300/300 V05 300/500 V07 450/750 V

Insulation Material

B (EPR) Ethylene-Propylene RubberG (EVA) Ethylene-Vinylacetat CopolymerN2 (CR) Chloroprene Rubber for welding cablesR (NR a./o. SR) Natural a./o. Synthetic RubberS (SiR) Silicone Rubber V (PVC) Polyvinyl Chloride V2 (PVC) Polyvinyl Chloride heat-resistant V3 (PVC) Polyvinyl Chloride low-temperature V4 (PVC) Polyvinyl Chloride cross-linkedZ (PE) Polyethylene cross-linked

Structural Elements

C ScreenQ4 (PA) Additional polymide core jacketT Additional textile braiding over laid-up coresT6 Additional textile braiding over individual cores

Sheath/Jacket Material

B (EPR) Ethylene-Propylene RubberJ Glass Fibre BraidN (CR) Chloroprene RubberN2 (CR) Chloroprene Rubber for welding cablesN4 (CR) Chloroprene Rubber heat-resistantQ (PUR) PolyurethaneR (NR a./o. SR) Natural a./o. Synthetic RubberT Textile braid

T2 Textile braid with flame retardant compound V (PVC) Polyvinyl Chloride V2 (PVC) Polyvinyl Chloride heat-resistant V3 (PVC) Polyvinyl Chloride low-temperature V4 (PVC) Polyvinyl Chloride cross-linked V5 (PVC) Polyvinyl Chloride oil-resistant

Special Structural Features

D3 Stress-relieving element (support wire)D5 Centre core (no supporting elements)FM Telecommunications cores integrated in power cablesH Flat, separable cable (twin cable)H2 Flat, non-separable cable (two-core sheathed cable)H6 Flat, non-separable cable (multi-core and multiple sheathed cable)H7 Two-layer insulating jacketH8 Spiral cables

Conductor Type

D Finely stranded, for welding cablesE (Very) finely stranded, for welding cablesF Finely stranded, for cables for fixed installationH (Very) finely stranded, for flexible cablesK Finely stranded, for cables for fixed installationR Multiple-wire, round, class 2U Single-wire, round, class 1 Y Tinsel wire, DIN 47104

Number of cores

Earth Core

G With earth coreX Without earth core

Conductor Nominal Cross Section in mm2

Examples:H07V-U 2.5 black (according to DIN VDE 0281)Harmonized PVC-insulated single-core sheathedcable, 2.5 mm2 single-core, nominal voltage 750 V

H07RN-F 3G, 1,5 (according to DIN VDE 0282)Harmonized rubber-sheathed cable for mediumtensile loads, three-core 1.5 mm2, finely stranded,green-yellow earth core, nominal voltage 750 V

Page 426: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 426/430

425

T E C H

N I C A L D A T A

Comparison of Harmonized Cables With IEC, DIN VDE and HD

E L KA B E L

PVC-Insulated Cables According to DIN VDE 0281 in Comparison with IEC and HD

Designation Accord. Short Short Nominal Nominal According Comparative

to VDE Designation Designation Cross-Sec- Voltage - to HD design

Part... New Old tion Uo/U (v) to IEC

VDE 0250 (mm2)PVC-Wiring CablesSingle Wire 0281 part 3 H 05V-U NYFA, NYA 0.5 to 1.0 300/500 HD 21.3 S3 227 IEC 05Fine Wires 0281 part 3 H 05V-K NYFAF, NYAF 227 IEC 06PVC-Insulated CablesSingle Wire 0281 part 3 H 07V-U NYA 1.5 to 10 227 IEC 01Multi-Stranded Wires 0281 part 3 H 07V-R NYA 1.5 to 40 450/750 HD21.3 S3 227 IEC 01Fine Wires 0281 part 3 H 07V-K NYAF 1.5 to 240 227 IEC 02Light PVC-Twin Cables 0281 part 5 H 03VH-Y NLYZ 0.1 300/300 HD 21.5 S3 227 IEC 41Twin Cables 0281 part 5 H 03VH-H NYZ 0.5+0.75 300/300 HD 21.5 S3 227 IEC 42PVC-Sheathed Cables 03VV-Fround 0281 part 5 H 03VV-F NYLHY rund 0.5+0.75 300/300 HD 21.5 S3 227 IEC 52flat 0281 part 5 H 03VVH2-F NYLHY flach 0.5+0.75 227 IEC 52

PVC-Sheathed Cables 05 VV-F

round 0281 part 5 H 05VV-F NYMHY rund 0.75+2.5 300/500 227 IEC 53NYMHY rund 1 to 2.5 HD 21.5 S3

flat 0281 part 5 H 05VVH2-F NYMHY flach 0.75 300/500 227 IEC 53PVC-Flat Cable 05VV-H6 0281 part 403 H 05VVH6-F NYFLY 0.75 to 1 300/500 - -PVC-Flat Cable 07VV-H6 0281 part 404 H 07VVH6-F NYFLY 1.5 to 25 450/750 -

Page 427: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 427/430

Type designation H05V-U, -K H03RT-F, A03RT-F H07RN-F, A07RN-FH07V-U, -R, -K H05RR-F, A05RR-F H05W5-F, H05WC4V5-KH07V3-U, -R, -K H05RN-F, A05RN-FH05V2-U, H05V2-K H07RN-F, A07RN-FH07V2-U, H07V2-K H03VH-Y 1),H03VH-HH05S-U, H05S-K H03W-F, A03W-F,

H05RN-F, H07RN-F H03WH2-FH05W-F, A05W-F,H05WH2-FN2GMH2G

Installation: in open air upon or on surface

*in open air*upon or on surface

Number of loaded cores 1 2 3 2 or 3

Cross-section, mm2 Current ratings in Ampere (A)

0,5 - 3 3 90,75 15 6 6 121 19 10 10 151,5 24 16 16 182,5 32 25 20 264 42 32 25 346 54 40 - 4410 73 63 - 6116 98 - - 8225 129 - - 10835 158 - - 13550 198 - - 16870 245 - - 20795 292 - - 250120 344 - - 292

150 391 - - 335185 448 - - 382240 528 - - 453300 608 - - 523400 726 - - -500 830 - - -

Conversion factors for deviating ambient temperature, grouping, installation under the ceiling, multicore cables and insulated wires - see DIN VDE 0298 part 4.

1) Nominal cross-sectional area 0,1 mm2, loadable with 0,2 A, independent of the ambient temperature.

≥d

≥d

426

T E C H N I C A L

D A T A

Current ratings for cables and insulated wiresup to 1000 V and heat resistant cablesPermissible operating temperature at conductor 40o C to 180 oC as per type

Ambient temperature 30 oC to 150 oC, as per type

E L KA B E L

Page 428: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 428/430

427

T E C H

N I C A L D A T A

Permissible Minimum Bending Radiusaccording to DIN VDE Specifications

E L KA B E L

The indicated values for bending radius stated in the following table are not permitted to fall below the value. For non-

complience of the values a short longevity is to be expected.

Permissible Minimum Bending Radius for Power Cables according to DIN 0298 - Part 3

- Nominal Votage 0.6/1 kV

Cables for Fixed InstallationsOuter ∅ of Cables or Thickness of Flat Cable in mm (D)

Method of Laying Up to 10 mm > 10 to 25 mm > 25 mm

- for permanent laying 4xD 4xD 4xD

- to form out 1xD 2xD 3xD

For Flexible Cables up to 8 mm > 8 mm to 12 mm >12 to 20 mm >20 mm

- for fixed installation 3xD 3xD 4xD 4xD

- for free movement 3xD 4xD 5xD 5xD

- to the inlet 3xD 4xD 5xD 5xD

- for forced guiding operation 5xD 5xD 5xD 6xD

(such as trailing)

- Operation for trolly cable 3xD 4xD 5xD 5xD

- operation in power drag chain 4xD 4xD 5xD 5xD

- operation for return sheave 7.5xD 7.5xD 7.5xD 7.5xD

D = outer ∅ of cables or thickness of flat table

Page 429: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 429/430

Construction reference

Basic cable Type with additional Information

A outdoor cable

I installation cable

YV/Li ... jumper wires/hook-up wires

Insulation

P dry paper

Y PVC (Polyvinylchloride)

2Y PE (Polyethylene)

02Y foamed PE (cellular)

02YS foam-skin insulation

Screening

C screen of braided tinned copper wires

F filling of cable core with petrol-jelly

(St) screen of plastic coated metallic foil(L) aluminium tape

Sheath Material

L smooth aluminium sheath

M lead sheath

(L)2Y copolymer coated aluminium

Mz lead alloy sheath

moisture barrier sheath

Protective Coating

Y PVC sheath

2Y PE sheath

Number of Stranding Elements

..x1x single core

..x2x pair (double core)

..x3x triple

..x4x quad

..x5x five-core

Conductor Diameter in mm

Type of Stranding Components

St I star quad without phantom circuit

P twisted pair

PiMF pair in metal foil

St III star quad in local (Subscriber) cable

Stranding Layout

Lg layer stranded concentric

Bd unit stranding

Armouring Wire

b armouring

B armouring of steel band for inductive protection

1B 0.3 1 layer steel tape, thickness 0.3 mm

2B 0.5 2 layers steel tape, thickness 0.5 mm

428

T E C H N I C A L

D A T A

DESIGNATION CODE FOR TELEPHONE CABLES,JUMPER WIRES AND STRANDED HOOK-UP WIRESaccording to DIN VDE 0271/0276

E L KA B E L

Page 430: Elkabel En

7/14/2019 Elkabel En

http://slidepdf.com/reader/full/elkabel-en 430/430

T E C H

N I C A L D A T A

STRUCTURE OF TELECOMMUNICATION CABLES A-2Y(L)2Y; A-2YF(L)2Y; A-02YSF(L)2Y

2. Sub-unit formation

Each sub-unit consists of 5 quads

(10 pair sub-unit)

No. 1 White quad No. 2 Yellow quad No. 3 Gray quad

1. Quad formation and colour scheme

No. 4 Brown quad No. 5 Black quad

3. Unit formation

1. 50 pairs units consist of 5 sub-units

2. 100 pairs units consist of 10 sub-units

Colour of sub-unit binding tapes

YellowGray

Yellow