LIGHTING FIXTURES. REFER TO "LIGHTING FIXTURE SCHEDULE". EMERGENCY LIGHTING FIXTURES. REFER TO "LIGHTING FIXTURE SCHEDULE". ABBREVIATIONS (NOT ALL ABBREVIATIONS ARE NECESSARILY USED ON THIS PROJECT) + MOUNTING HEIGHT ABOVE FINISHED FLOOR COORDINATE WITH ARCHITECTURAL PLANS (E) EXISTING TO REMAIN (ER) EXISTING TO BE REMOVED (ERR) REMOVED & RELOCATED (ERRO) REMOVED & RETURNED TO OWNER (N) NEW (RE) RELOCATED EXISTING 1P SINGLE POLE 2P TWO POLE 3P THREE POLE A AMPERE AF AMPERE FRAME AFF ABOVE FINISHED FLOOR AIC AMPERE INTERRUPTING CAPACITY AT AMPERE TRIP ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BLDG BUILDING C CONDUIT & DEGREE CELSIUS CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CD CANDELA CL CEILING MOUNT CKT CIRCUIT CONT CONTINUATION CU COPPER DEG DEGREE DIA DIAMETER DISC DISCONNECT DIV DIVISION EA EACH EC ELECTRICAL CONTRACTOR ELEC ELECTRICAL EM EMERGENCY EMT ELECTRICAL METALLIC TUBING ) DEGREE FAHRENHEIT FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FAAP FIRE ALARM ANNUNCIATOR PANEL FATC FIRE ALARM TERMINATION CABINET FC FOOT CANDLE FDR FEEDER FL FLOOR FLA FULL LOAD AMPERES FLEX FLEXIBLE FMC FLEXIBLE METAL CONDUIT G GROUND GFI GROUND FAULT INTERRUPTER GRC GALVANIZED RIGID CONDUIT HP HORSE POWER HZ HERTZ IG ISOLATED GROUND IMC INTERMEDIATE METAL CONDUIT JB JUNCTION BOX KCMIL THOUSAND CIRCULAR MILS KV KILOVOLT KVA KILOVOLT AMPERE KW KILOWATT KWH KILOWATT HOUR LTG LIGHTING MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MCM THOUSAND CIRCULAR MILS MI MINERAL INSULATED CABLE MTD MOUNTED N NEUTRAL NC NORMALLY CLOSED NO NORMALLY OPEN P POLE PB PULL BOX PHASE PNL PANEL PVC POLYVINYL CHLORIDE CONDUIT PWR POWER REC RECEPTACLE RMC RIGID METAL CONDUIT SPD SURGE PROTECTION DEVICE SPEC SPECIFICATION SW SWITCH SWBD SWITCHBOARD SYS SYSTEMS TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION TYP TYPICAL UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTED POWER SUPPLY V VOLTS VIF VERIFY IN FIELD VFD VARIABLE FREQUENCY DRIVE WP WEATHERPROOF XFMR TRANSFORMER Y WYE ǻ DELTA VOICE / DATA SYMBOLS RISER / SINGLE LINE SYMBOLS POWER SYMBOLS 100/90/3 ATS 100A 480V,4P 208/120V 460V 500KVA 60/30/3 MOTOR RATED TOGGLE SWITCH, 20A SINGLE POLE, UON HORSEPOWER RATED WITH OVERLOAD PROTECTION. SINGLE POLE SWITCH FLUSH WALL MOUNTED @ 48" AFF, UON 3 = THREE-WAY 4 = FOUR-WAY D = INTEGRAL DIMMER OS = INTEGRATED OCCUPANCY SENSOR HOMERUN-NUMERAL WHERE USED INDICATES DESIGNATED PANEL AND CIRCUIT NUMBER FOR REFERENCE ONLY. WHERE CONDUIT IS NOT SPECIFIED USE AC OR MC CABLE FOR APPLICATION. 2#12, #12G, 3/4"C HOMERUN, UON 3#12, #12G, 3/4"C HOMERUN, UON 4#12, #12G, 3/4"C HOMERUN, UON AT 120V AND OVER 100' CIRCUIT LENGTH PROVIDE #10 MINIMUM. AT 277V AND OVER 200' CIRCUIT LENGTH PROVIDE #10 MINIMUM. 15 or 20A, 125V QUADRUPLEX RECEPTACLE, W/ ISOLATED GROUND FLUSH WALL MOUNTED @ 18" AFF, UON NUMBER INDICATES QUANTITIES OF IG TYPE RECEPTACLES. 1 = ONE DUPLEX IG TYPE & ONE DUPLEX STANDARD G. RECEPTACLE 2 = QUADRUPLEX IG TYPE RECEPTACLES JUNCTION BOX MOUNTED ABOVE SUSPENDED CEILING / FLUSH WALL INSTALLED WITHIN 2' OF EQUIPMENT AND CONNECTED VAV = DEDICATED TO VARIABLE AIR VOLUME BOX CONTROL SD = DEDICATED TO SMOKE DAMPER MD = DEDICATED TO MOTORIZED VOLUME DAMPER UH = UNIT HEATER EWC = ELECTRIC WATER COOLER DMO = DOOR MOTOR OPERATOR VOICE/DATA OUTLET FLUSH WALL MOUNTED @ 18" AFF UON, WITH 3/4" CONDUIT IN DEMISING WALL, 7(50,1$7(' ,1 $ %(1' ,172 $&&(66,%/( &(,/,1* SPECIAL PURPOSE RECEPTACLE. NEMA TYPE AS INDICATED FLUSH CEILING MOUNTED 20A, 125V QUADRUPLEX RECEPTACLE FLUSH CEILING MOUNTED 20A, 125V DUPLEX RECEPTACLE FLUSH CEILING MOUNTED 3 PHASE SPECIAL PURPOSE RECEPTACLE. NEMA TYPE AS INDICATED FLUSH WALL MOUNTED @ 18" AFF, UON SPECIAL PURPOSE RECEPTACLE. NEMA TYPE AS INDICATED FLUSH WALL MOUNTED @ 18" AFF, UON DROP CORD RECEPTACLE CEILING MOUNTED 15 or 20A, 125V SURGE SUPPRESSION DUPLEX RECEPTACLE FLUSH WALL MOUNTED @ 18" AFF, UON 15 or 20A, 125V DUPLEX RECEPTACLE CONTROLLED BY WALL SWITCH FLUSH WALL MOUNTED @ 48" AFF, UON 20A, 125V, 2P W/G. SINGLE RECEPTACLE FLUSH WALL MOUNTED @ 18" AFF, UON EWC = ELECTRIC WATER COOLER 15 or 20A, 125V EMERGENCY QUADRUPLEX RECEPTACLE FLUSH WALL MOUNTED @ 18" AFF, UON 15 or 20A, 125V EMERGENCY DUPLEX RECEPTACLE FLUSH WALL MOUNTED @ 18" AFF, UON 15 or 20A, 125V DUPLEX RECEPTACLE FLUSH WALL MOUNTED @ 18" AFF, UON C = GRAY COLORED RECEPTACLE FOR COMPUTERS T = TAMPER PROOF XP = EXPLOSION PROOF 15 or 20A, 125V QUADRUPLEX RECEPTACLE FLUSH WALL MOUNTED @ 18" AFF, UON 15 or 20A, 125V DUPLEX RECEPTACLE, GFI TYPE FLUSH WALL MOUNTED @ 18" AFF, UON WP = WEATHER PROOF 15 or 20A, 125V SINGLE RECEPTACLE, W/ ISOLATED GROUND FLUSH WALL MOUNTED @ 18" AFF, UON 15 or 20A, 125V DUPLEX RECEPTACLE, W/ ISOLATED GROUND FLUSH WALL MOUNTED @ 18" AFF, UON TAPBOX, SPLICE BOX CONDUIT OR RACEWAY TURNING UP CONDUIT OR RACEWAY TURNING DOWN CAPPED CONDUIT CONDUIT WITH BUSHING NEW UNDERGROUND/UNDER SLAB CONDUIT SPLICE (JUNCTION) OF PATHS OF CONDUCTORS OR CABLES. TRANSFORMER COMBINATION MOTOR CONTROLLER / DISCONNECT SWITCH <SWITCH AMPS>/<POLES>, VOLTAGE RATING AS REQUIRED VFD = VARIABLE FREQUENCY DRIVE UNFUSED DISCONNECT SWITCH <SWITCH AMPS>/<POLES>, VOLTAGE RATING AS REQUIRED FUSED DISCONNECT SWITCH <SWITCH AMPS>/<FUSE AMPS>/<POLES>, VOLTAGE RATING AS REQUIRED ENCLOSED CIRCUIT BREAKER <FRAME AMPS>/<TRIP AMPS>/<POLES>, VOLTAGE RATING AS REQUIRED ST = SHUNT TRIP 208/120V PANELBOARD SURFACE MOUNTED 208/120V PANELBOARD FLUSH MOUNTED 208/120V DISTRIBUTION PANELBOARD SURFACE MOUNTED 480/277V PANELBOARD SURFACE MOUNTED 480/277V PANELBOARD FLUSH MOUNTED 480/277V DISTRIBUTION PANELBOARD SURFACE MOUNTED MOTOR GENERATOR GROUND CONNECTION TRANSFER SWITCH ATS = AUTOMATIC TRANSFER MTS = MANUAL TRANSFER POLES AND RATING AS NOTED POWER TRANSFORMER VOLTAGES, WINDINGS AND SIZE AS INDICATED CIRCUIT BREAKER - MOLDED CASE TYPE <FRAME AMPS>/<TRIP AMPS>/<POLES> CURRENT TRANSFORMER FLOOR MOUNTED METAL SUPPORT FRAME FOR ELECTRICAL ENCLOSURES NEW LOW VOLTAGE/CONTROL WIRING VFD ANNOTATION SYMBOLS KEY NOTE EQUIPMENT PROVIDED BY OTHERS ST NEW GROUND CABLE 100/3 30/3 100/60/3 NEW CONDUIT/CIRCUIT/EQUIPMENT ELECTRICAL SYMBOLS LIST (NOT ALL SYMBOLS ARE NECESSARILY USED ON THIS PROJECT) 20/1 GENERAL NOTES 1. THE SUBMISSION OF A BID BY THE ELECTRICAL CONTRACTOR IS NOTIFICATION THAT THE ELECTRICAL CONTRACTOR HAS TOTALLY FAMILIARIZED HIMSELF WITH THE CONTRACT DOCUMENTS AND EXISTING SITE CONDITIONS AND HAS AGREED TO PROVIDE THE NECESSARY LABOR AND MATERIAL FOR THE COMPLETE INSTALLATION OF EACH SYSTEM IN A NEAT AND WORKMANLIKE MANNER IN ACCORDANCE WITH THE BEST PRACTICES OF THE INDUSTRY AND IN COMPLIANCE WITH ALL AUTHORITIES HAVING JURISDICTION. 2. THESE DRAWINGS ARE PRESENTED TO THE ELECTRICAL CONTRACTOR WITH THE UNDERSTANDING THAT THE ELECTRICAL CONTRACTOR IS AN EXPERT AND COMPETENT IN THE PREPARATION OF CONTRACT BID PRICES ON THE BASIS OF INFORMATION SUCH AS IS CONTAINED IN THESE DOCUMENTS. IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO CALL FOR FINISHED WORK, TESTED AND READY FOR OPERATION AND IN COMPLETE CONFORMANCE WITH ALL APPLICABLE CODES, RULES, AND REGULATIONS. MINOR ITEMS NOT USUALLY SHOWN OR SPECIFIED, BUT MANIFESTLY NECESSARY FOR THE PROPER INSTALLATION AND OPERATION OF THE VARIOUS SYSTEMS, SHALL BE INCLUDED IN THE WORK AND IN THE PROPOSAL THE SAME AS IF SPECIFIED OR SHOWN ON THE DRAWINGS. IF ANY DEPARTURES FROM THE DRAWINGS ARE DEEMED NECESSARY, DETAILS OF SUCH DEPARTURES AND THE REASONS THEREFORE SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL. NO DEPARTURES SHALL BE MADE WITHOUT PRIOR APPROVAL OF SEPTA. 3. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL DIMENSIONS IN THE FIELD, AND SHALL ADVISE THE PROJECT MANAGER AND THE OWNER OF ANY DISCREPANCIES BEFORE PERFORMING THE WORK. 4. THE DRAWINGS INDICATE ARRANGEMENTS AND APPROXIMATE SIZES AND RELATIVE LOCATIONS OF PRINCIPAL APPARATUS, EQUIPMENT, DEVICES, AND SERVICES TO BE PROVIDED. DRAWINGS ARE DIAGRAMMATIC AND ARE A GRAPHIC REPRESENTATION OF CONTRACT REQUIREMENTS TO THE BEST AVAILABLE STANDARDS AT THE SCALE INDICATED. 5. LAYOUT OF EQUIPMENT INDICATED ON THE DRAWINGS SHALL BE CHECKED AND COMPARED AGAINST ALL DRAWINGS AND SPECIFICATIONS OF ALL TRADES AND EXACT LOCATIONS DETERMINED USING APPROVED SHOP DRAWINGS OF SUCH EQUIPMENT. WHERE PHYSICAL INTERFERENCES OCCUR, CONSULT WITH THE PROJECT MANAGER AND PREPARE DATED, DIMENSIONED DRAWINGS COORDINATED WITH ALL OTHER TRADES WORKING IN THIS AREA AND CORRECTING SUCH INTERFERENCE. 6. ELECTRICAL CONTRACTOR SHALL SCHEDULE HIS WORK IN ACCORDANCE WITH THE CONSTRUCTION SCHEDULE SO THAT ALL OF HIS WORK CAN BE INSTALLED WITHOUT DELAYING THE PROJECT. ALL WORK RELATED TO SHUTDOWN OF EXISTING SERVICES SHALL BE PERFORMED AT THE HOURS DESIGNATED BY SEPTA WITH ALL ASSOCIATED COSTS BORNE BY THE ELECTRICAL CONTRACTOR AT NO COST TO SEPTA. PROVIDE ANY TEMPORARY FACILITIES REQUIRED TO PERMIT SEPTA'S USE OF EXISTING FACILITIES AND SYSTEMS TO REMAIN UNDISTURBED. COORDINATE ALL WORK, INCLUDING ALL SHUTDOWNS THAT AFFECT SYSTEMS AND/OR PORTIONS OF THE BUILDING THAT MUST REMAIN IN OPERATION, WITH SEPTA. 7. ELECTRICAL CONTRACTOR SHALL SECURE AND PAY ALL FEES, LICENSES, INSPECTIONS, AND PERMITS PERTAINING TO THE CONTRACT. SUBMIT TO SEPTA DUPLICATE CERTIFICATES OF INSPECTION FROM APPROVED INSPECTION AGENCY. 8. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS. 9. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR WORKMEN'S IDENTIFICATION AND BADGING, SAFETY AND FIRE PROTECTION, BARRICADES, WARNING SIGNS, TRASH REMOVAL, CUTTING AND PATCHING. 10. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RIGGING, HANDLING, AND PROTECTION OF MATERIALS. ALL EQUIPMENT AND MATERIALS SHALL BE NEW AND WITHOUT BLEMISH OR DEFECT. ALL EQUIPMENT INSTALLED SHALL BEAR THE LABEL OF AN APPROVED AGENCY. 11. ELECTRICAL CONTRACTOR SHALL PROVIDE LABOR TO RECEIVE, UNLOAD, STORE, PROTECT, AND TRANSFER TO POINT OF INSTALLATION FOR ALL FURNISHED ITEMS. 12. WHERE CONDUIT, CABLES, DUCTWORK, OR PIPING PASSES THROUGH FIRE RATED FLOORS OR WALLS, THE PENETRATION SHALL BE COMPLETELY SEALED WITH A FIRE STOP MATERIAL THAT IS UL LISTED, FM GLOBAL APPROVED (WWW.FMGLOBAL.COM/PAGE.ASPX?ID=50030000) AND ACCEPTED BY THE BUILDING DEPARTMENT AND FIRE DEPARTMENT AS BEING SUITABLE FOR THIS SERVICE. THIS MATERIAL SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER TO MAINTAIN THE UL LISTED FIRE RATING OF THE PENETRATED WALL OR FLOOR. 13. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SLAB OPENINGS, WALL OPENINGS, BEAM PENETRATIONS, AND CORING AS IT RELATES TO HIS WORK. ELECTRICAL CONTRACTOR SHALL SUBMIT SIZE AND LOCATION FOR REVIEW AND APPROVAL. 14. ALL EXTERIOR WALL OPENINGS SHALL BE SLEEVED, PROPERLY CAULKED, AND SEALED WITH A HIGH QUALITY SEALANT TO PREVENT INFILTRATION OF MOISTURE AND OUTSIDE AIR. 15. CONTRACTOR SHALL SUBMIT SCHEDULE OF SUBMITTALS PRIOR TO SUBMITTING ANY SHOP DRAWINGS, ETC. TO BE SUBMITTED FOR THIS PROJECT, INCLUDING THE ANTICIPATED DATE OF EACH SUBMISSION. CONTRACTORS SHALL SUBMIT (6) SETS OF COMPLETE SHOP DRAWINGS AND CATALOG CUTS, WIRING DIAGRAMS AND ASSOCIATED DATA TO THE PROJECT MANAGER FOR APPROVAL PRIOR TO PURCHASING EQUIPMENT OR STARTING ANY WORK. ANY WORK INSTALLED OR EQUIPMENT PURCHASED PRIOR TO RECEIPT OF PROJECT MANAGER APPROVED SHOP DRAWINGS THAT REQUIRES CHANGES SHALL BE REPLACED AT CONTRACTOR'S EXPENSE. 16. SUBMIT CATALOG INFORMATION, FACTORY ASSEMBLY DRAWINGS AND FIELD INSTALLATION DRAWINGS AS REQUIRED FOR A COMPLETE EXPLANATION AND DESCRIPTION OF ALL ITEMS TO BE PROVIDED. THE ELECTRICAL CONTRACTOR SHALL REVIEW AND APPROVE ALL SHOP DRAWINGS. NO SUBMISSION WILL BE ACCEPTED WITHOUT THE SIGNED APPROVAL OF THE ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL CHECK AND VERIFY ALL FIELD MEASUREMENTS. 17. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL SUPPLY THE PROJECT MANAGER WITH (1) COMPLETE SET OF CAD AS-BUILT DRAWINGS IN AUTOCAD 2000 AT CONTRACTOR'S EXPENSE AND (3) &203/(7( %281' &23,(6 2) 23(5$7,21 $1' 0$,17(1$1&( 0$18$/6 7+(6( 6+$// %( 3529,'(' 72 SEPTA AT CONTRACTOR'S EXPENSE. CONTRACTOR SHALL INSTRUCT SEPTA'S PERSONNEL WITH REGARD TO THE PROPER OPERATION OF ALL SYSTEMS TO THE SATISFACTION OF SEPTA. 18. ALL WORK FURNISHED UNDER THE CONTRACT SHALL BE GUARANTEED AGAINST ANY AND ALL DEFECTS IN WORKMANSHIP AND/OR MATERIALS FOR A PERIOD OF NOT LESS THAN (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE OF THE INSTALLATION. ANY DEFECTS OF WORKMANSHIP DEVELOPING DURING THIS PERIOD SHALL BE REMEDIED AND ANY DEFECTIVE MATERIAL REPLACED WITHOUT ADDITIONAL COST TO SEPTA. 19. INSTALLED SYSTEMS SHALL OPERATE UNDER ALL CONDITIONS OF LOAD WITHOUT SOUND OR VIBRATION THAT IS OBJECTABLE TO THE PROJECT MANAGER, OR SEPTA. OBJECTABLE SOUND OR VIBRATION CONDITIONS DUE TO WORKMANSHIP SHALL BE CORRECTED IN APPROVED MANNER BY THE ELECTRICAL CONTRACTOR AT HIS EXPENSE. 20. ELECTRICAL CONTRACTOR SHALL SIMILARLY NOTIFY ENGINEER OF COMPLETION OF ALL WORK, INDICATING THE ELECTRICAL CONTRACTOR IS READY FOR THE ENGINEER TO PERFORM THE FINAL PUNCHLIST INSPECTION. 21. UPON COMPLETION OF ALL UNFINISHED OR FAULTY WORK NOTED IN ENGINEER FINAL PUNCH LIST, THE ELECTRICAL CONTRACTOR SHALL SUBMIT TO THE ENGINEER IN WRITING A LETTER OF COMPLETION CERTIFYING THAT ALL PUNCH LIST ITEMS HAVE BEEN COMPLETED AND ALL AS-BUILTS, MANUALS, ETC. HAVE BEEN SUBMITTED. 22. SHOULD A CONTRACTOR REQUIRE REMOVAL, RELOCATION, OR REROUTING OF ANOTHER TRADE'S WORK THAT IS NOT INDICATED ON DRAWINGS, THE CONTRACTOR REQUIRING SUCH WORK SHALL BE RESPONSIBLE FOR THAT WORK, AND PAY ALL REQUIRED COSTS. 23. ALL WORK INVOLVING ALTERATIONS TO EXISTING SYSTEMS, EQUIPMENT, AND MATERIALS SHALL BE REVIEWED WITH THE PROJECT MANAGER AND SEPTA BEFORE BEGINNING WORK. 24. DEFINITION: UNLESS OTHERWISE NOTED, ALL WORK SPECIFIED HEREIN OR NOTED ON DRAWINGS, SHALL BE BY THE ELECTRICAL CONTRACTOR. ALL REFERENCES TO "CONTRACTOR" OR "THIS CONTRACTOR" ON DRAWINGS OR SPECIFICATIONS ARE ADDRESSED TO THE ELECTRICAL CONTRACTOR. THE TERM "PROVIDE" WHENEVER ENCOUNTERED ON DRAWINGS OR IN THESE SPECIFICATIONS, SHALL MEAN "FURNISH AND INSTALL." 25. CODES AND STANDARDS: ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE, ALL APPLICABLE CODES, SPECIFICATIONS, LOCAL ORDINANCES, INDUSTRY STANDARDS, UTILITY COMPANY REGULATIONS AND FIRE INSURANCE CARRIER'S REQUIREMENTS. 26. MATERIALS: ALL MATERIALS FURNISHED BY THIS CONTRACTOR, SHALL BE NEW AND BEAR THE LABEL OR LISTING OF A NATIONALLY RECOGNIZED INDEPENDENT TESTING LABORATORY. 27. OUTLET AND SWITCH BOXES: PROVIDE AND INSTALL OUTLET BOXES OF PROPER TYPE AND SIZE AS REQUIRED AT ALL OUTLETS WHERE SHOWN. SECURED FIRMLY IN PLACE AND SET TRUE AND SQUARE AND FLUSH WITH THE FINISHED SURFACE. 28. INSTALLATION OF RACEWAYS: ALL RACEWAYS SHALL BE INSTALLED CONCEALED. NO SURFACE RACEWAY WILL BE ACCEPTED IN FINISHED AREAS. 29. WIRING: WIRING OF BRANCH CIRCUITS SHALL BE TYPE THHN/THWN IN RIGID GALVANIZED STEEL CONDUIT :+(5( (;326(' 2876,'( :,5(6 6+$// %( &233(5 $1' 6+$// %( 0,1 $:* 9 & $// RACEWAYS ARE SHOWN DIAGRAMMATICALLY, EXACT LOCATION TO BE DETERMINED ON THE JOB. EXACT LOCATION OF OUTLETS TO BE DETERMINED BY SEPTA. CONTRACTOR SHALL ARRANGE ALL NEW CIRCUITS IN PANELS SO AS TO BALANCE THE LOAD ON ALL PHASES. EXPOSED CONDUIT IN UNFINISHED AREAS SHALL BE EMT. CONDUIT DIRECTLY BURIED UNDERGROUND SHALL BE SCHEDULE 40 PVC WITH RGS ELBOWS AND STUB UPS. 30. A TYPED DIRECTORY CARD SHALL BE PROVIDED IN EACH PANEL WITH ADDED CIRCUITS TO INDICATE THE LOADS ACTUALLY SERVED. 31. PROVIDE NEW FIXTURES AS SPECIFIED ON LIGHTING FIXTURE SCHEDULE. ALL NEW LED LAMPS SHALL BE 3500K. 32. GROUNDING: SHALL BE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE ARTICLE 250. PROVIDE GROUND WIRES AS REQUIRED AND RESIZE CONDUIT IF NECESSARY. 33. DEMONSTRATION OF COMPLETE ELECTRICAL SYSTEMS: UPON COMPLETION OF THE WORK THIS CONTRACTOR SHALL OBTAIN A CERTIFICATE OF APPROVAL FROM ALL RECOGNIZED AGENCIES CONCERNED WITH THE WORK. CONTRACTOR SHALL NOTIFY AND MAKE ALL THE NECESSARY ARRANGEMENTS WITH THE INSPECTING AGENCY AND LOCAL AUTHORITIES SO THAT INSPECTION MAY BE CARRIED OUT AT THE PROPER TIME. 34. PROJECT MUST MEET FM GLOBAL STANDARDS (WWW.FMGLOBAL.COM/) METER LIGHTING SYMBOLS JUNCTION BOX OR POKE-THRU WITH COMBINATION POWER/DATA FLUSH FLOOR MOUNTED REFER TO DETAIL ON DRAWING E002 NEW EMERGENCY CIRCUIT UNDERGROUND SECONDARY CABLE SHOWN HERE FOR REFERENCE ONLY. SEE CIVIL PLANS UNDERGROUND TELEPHONE CABLE SHOWN HERE FOR REFERENCE ONLY. SEE CIVIL PLANS 2&&83$1&< 6(1625 5$1*( CEILING MOUNTED PHOTOCELL CONTROL SWITCH CEILING MOUNTED PHOTOCELL CONTROL SWITCH WALL MOUNTED @ 10" BELOW FINISHED CEILING ELECTRICALLY HELD UL LISTED RELAY FOR EMERGENCY LIGHTING. LIGHTING SHALL BE CONTROLLED BY SWITCH UNDER NORMAL POWER CONDITION FROM NORMAL SOURCE. IN EMERGENCY MODE THE RELAY SHALL ENABLE THE DEDICATED LIGHTING TO BE SWITCHED TO THE EMERGENCY SOURCE FOR FULL OPERATION. PROVIDE BODINE BALLAST #GTD OR SIMILIAR. TIME CLOCK MANHOLE ELECTRICALLY HELD UL LISTED RELAY FOR EMERGENCY LIGHTING. LIGHTING SHALL BE CONTROLLED BY SWITCH UNDER NORMAL POWER CONDITION FROM NORMAL SOURCE. IN EMERGENCY MODE THE RELAY SHALL ENABLE THE DEDICATED LIGHTING TO BE SWITCHED TO THE EMERGENCY SOURCE FOR FULL OPERATION. PROVIDE BODINE BALLAST #GTD OR SIMILIAR. ELECTRIC DOOR STRIKE CARD READER, PROVIDE 2"x4" JUNCTION BOX WALL MOUNTED @ 42" AFF UON ON NON-SECURED SIDE OF DOOR ADA ACCESS BUTTON, MAKE ALL FINAL CONNECTIONS TO DOOR CONTROLLER DOOR CONTROLLER SHEET NUMBER DWG. NO.: OF OF SHT. NO.: REV. NO.: SCALE: DRAWN BY: DATE: WORK ORDER NO.: SCALE FACTOR: CHECKED BY: ARCHIVE NO.: COMPUTER FILE NO.: ADDENDUM 1 4/17/15 1 MAN CWT CWT