1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 13 A B C D E F H I J K L M P Speech Therapy 2 Speech Therapy 4 Book TR Room 5 Medical Store 6 Book TR Room 1 Unoccupied Unoccupied Unoccupied Unoccupied Unoccupied Unoccupied Unoccupied Unoccupied WC & Shower 8 Staff WC 9 Hall 10 Womens Toilets 11 Mens Toilets 13 Wound Clinic 15 Medical Store 16 Wound Clinic 17 Bookable Room 18 Family Rm/Care Doc 19 Waiting Area 21 Community Welfare 22 Bookable Room 23 Room 24 Child Health 25 Sound Proof Room 26 Unoccupied Unoccupied Womens WC 12 Mens WC 14 Circuit1 Panel 1 Coffer Light - Parabolic Rectangular Reception 20 Circuit9 Panel 1 Coffer Light - Parabolic Rectangular Circuit11 Panel 1 Coffer Light - Parabolic Rectangular Circuit10 Panel 1 Coffer Light - Parabolic Rectangular Circuit12 Panel 1 Coffer Light - Parabolic Rectangular Circuit<unnamed> Coffer Light - Parabolic Rectangular Circuit6 Panel 2 Coffer Light - Parabolic Rectangular Circuit5 Panel 2 Coffer Light - Parabolic Rectangular Circuit4 Panel 2 Coffer Light - Parabolic Rectangular Circuit3 Panel 2 Coffer Light - Parabolic Rectangular Circuit2 Panel 2 Coffer Light - Parabolic Rectangular Circuit1 Panel 2 Recessed Direct-Indirect Light - Asymmetrical Circuit8 Panel 1 Coffer Light - Parabolic Rectangular Circuit7 Panel 1 Recessed Direct-Indirect Light - Asymmetrical Circuit6 Panel 1 Coffer Light - Parabolic Rectangular Circuit5 Panel 1 Coffer Light - Parabolic Rectangular Circuit4 Panel 1 Coffer Light - Parabolic Rectangular Circuit3 Panel 1 Coffer Light - Parabolic Rectangular Circuit11 Panel 2 Recessed Direct-Indirect Light - Asymmetrical Circuit12 Panel 2 Recessed Direct-Indirect Light - Asymmetrical Circuit8 Panel 3 Recessed Direct-Indirect Light - Asymmetrical Circuit7 Panel 3 Recessed Direct-Indirect Light - Asymmetrical Circuit3 Panel 3 Ceiling Light - Flat Round Recessed Direct-Indirect Light - Asymmetrical Circuit10 Panel 3 Coffer Light - Parabolic Rectangular Circuit9 Panel 3 Coffer Light - Parabolic Rectangular Circuit6 Panel 3 Coffer Light - Parabolic Rectangular Circuit4 Panel 3 Coffer Light - Parabolic Rectangular Circuit5 Panel 3 Coffer Light - Parabolic Rectangular Circuit2 Panel 1 Recessed Direct-Indirect Light - Asymmetrical Coffer Light - Parabolic Rectangular Scale LECTURER Drawn by Date Project number Institute of Technology Carlow BSc. in Architectural Technology Year 3 2015-2016 1 : 200 21/04/2016 15:20:34 Electrical Plan Layout 3 Calow Primary Health Care Centre Issue Date Xhevdet Haliti Dan O Sullivan, Noel Dunne, Mark Duffy A101 1 : 200 Ground floor - Ceiling Electrical layout 1 Notes: Total Est. Demand Current: 6 A Total Conn. Current: 9 A Total Est. Demand: 4034 VA Other 0 VA 0.00% 0 VA Total Conn. Load: 6112 VA Lighting - Dwelling Unit 6112 VA 66.00% 4034 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps: 7 A 10 A 11 A 1504 VA 2208 VA 2400 VA 12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A 11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A 10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A 9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 4.2 A 7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.7 A 6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A 3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A 1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A Circuit Number Circuit Designation Type of Wiring Circuit Conductors (csa) Live, Neutral, CPC Max Disconnection Time allowed by BS7671 Protective Device BS(EN) PD Type number PD Rating Short Circuit Capacity (kA) RCD Operating current (mA) Maximum Zs Permitted by BS 7671 A B C Notes: Enclosure: Type 1 MCB Rating: Mounting Type: Surface Mains Rating: 100 A DB supplied from: No. of Phases: 3 Mains Type: Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating: DB Schedule: Panel 1 Institute of Technology Carlow Notes: Total Est. Demand Current: 6 A Total Conn. Current: 9 A Total Est. Demand: 4245 VA Other 0 VA 0.00% 0 VA Total Conn. Load: 6432 VA Lighting - Dwelling Unit 6432 VA 66.00% 4245 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps: 7 A 12 A 9 A 1600 VA 2784 VA 2048 VA 12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A 11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 5.3 A 10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A 9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A 8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A 7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.8 A 6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A 2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 3.5 A 1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A Circuit Number Circuit Designation Type of Wiring Circuit Conductors (csa) Live, Neutral, CPC Max Disconnection Time allowed by BS7671 Protective Device BS(EN) PD Type number PD Rating Short Circuit Capacity (kA) RCD Operating current (mA) Maximum Zs Permitted by BS 7671 A B C Notes: Enclosure: Type 1 MCB Rating: Mounting Type: Surface Mains Rating: 100 A DB supplied from: No. of Phases: 3 Mains Type: Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating: DB Schedule: Panel 2 Institure of Technology Carlow Symmetrical design, no required top or bottom mountings Single-piece deadfront – no filler plates needed Smaller, lighter panel than Spectra Series panelboards Easy-to-install galvanized enclosures with removable endwalls Ready-to-install hinged trim options Branch-bus direct connection Up to 600A breaker mounted as a branch device Deeper (8"), wider (30") A-Series box to accommodate larger wire sizes Double branched 150A (ED/SE) and 225A (QD) breakers Vertically mounted main circuit breakers in 800A Captive hardware on branch breakers Staggered, center-mounted, larger frame breakers (SG, SF) for easy installation Bus-connected TVSS for maximum surge protection Narrow design to minimize footprint Enclosure available in NEMA Type 1, Type 3R/12, Type 4/4X An exceptional general lighting product that performs well in large spaces with high ceilings. Especially suitable for open office areas, public indoor spaces, libraries and airport waiting areas. Moon Two - High frequency direct / indirect recessed luminaires are a range of high efficiency luminaires designed to accommodate PL-L & T5 fluorescent lamps. These are suitable for general lighting in retail & commercial applications. Typical electrical room layout with suspended ceiling and recessed coffer lighting shown. Distrobution panel boards locate at Basement