Top Banner
electric heating systems
25

electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

Apr 11, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

electricheating systems

Page 2: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

www.elektra.eu

Page 3: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

Index

1. Introduction

2. Products

MDHeating Mats

Installation Accessories

SnowTec

UltraTec

DM

VCD

UWG4

UDG4

ETOG2

®

Heating Cables

Thermostats & Controllers

5

11

13

15

17

19

21

22

23

24

Page 4: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

www.elektra.eu

Page 5: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

Headquarters

ELEKTRAStock AvailabilityThroughout the EU and around the world, ELEKTRA

products are readily available through a network of

approved and authorized distributors, installers and even

dedicated websites.

ELEKTRALeading Brand

ELEKTRA specializes in electric heating systems for both

residential and commercial buildings. Established in

1985, the company is currently the largest and most

reputable producer of floor heating systems in Central

Europe. From the beginning product quality has been

the first priority for the company. This is the only way to

satisfy all customers and achieve and maintain

leadership in the market.

Distribution in dozens of countries acrossEurope, Asia, North America and Australia

Y E A R S

Page 6: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

The heightened mechanical

durability and flexibility

of ELEKTRA heating cables

is achieved through

the use of multi-stranded

wire construction of the cores.

Many years of continuous operation combined with the

latest technology ensures the expert ELEKTRA engineers

constantly develop new and innovative solutions.

ELEKTRA products remain at the forefront, providing the

highest level of quality and customer satisfaction.

Know-how & Experience

The rigorous selection, approval and use of an established

and qualitative raw material supply chain including:

Isabellenhütte, Sandvik, 3M & Borealis, ensures the

quality and integrity of ELEKTRA products.

Raw Material Control

Multi-wireConstruction

3

1

2

Both cores are heating, allowing equal power

distribution of 50% to each core.

This significantly lowers the actual operating

temperatures of the heating cores which prolongs

the life span of the products.

Dual Heating Cores4

www.elektra.eu

Page 7: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

Precise parameter settings are achieved with computer

controlled extrusion processes, ensuring correct structure

and necessary quality of the extruded insulation and

outer sheath.

Precise Extrusion

The use of double-layer

insulation in products

especially designed

for extremely demanding

operating conditions

ensures superior thermal

and electric features, thus

significantly enhancing

durability of the products.

Double-layerInsulation

5

Laser measurement equipment in extrusion lines

guarantees insulation and outer sheath thickness to

within a tolerance of 0,002" (0.05mm), and main-

tains uniform cable centricity.

Laser Measurement

6

7

Page 8: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

The necessary maintenance of uniform cable tension

and therefore stability of resistance is achieved

through the use of modern production machines at

each stage of the production process. This uniformity

and stabi l i ty i s conf i rmed with 6 indiv idual

measurements of heating wire resistance during

production.

Uniformityof Resistance

8

Only modern precision calibrated pneumatic devices

guaranteeing adequate uniform force of joint

clamping are used. The material and construction of

joints to the level of IPX7 minimum, guarantees the

protection of connections in products.

Faultless Joint

9

Production defects are wholly eliminated by rigorous

high voltage control monitoring in the production

line, and an additional final high voltage test of every

single product, not random testing.

High VoltageControl

10

www.elektra.eu

Page 9: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

The marking of each product with a unique

production code, means the history of the entire

production process and materials used in

manufacture can be traced.

Unique Code11

ELEKTRA quality confirmed by the research results

and ETL approvals.

Quality Confirmed

12

Page 10: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

www.elektra.eu

Page 11: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

MD

This package contains:• ELEKTRA heating mat,• 'cold tails' flexible conduit,• flexible conduit for the temperature

sensor, capped on one end,• instruction manual,• installation video, DVD for PC and Mac,• warning labels.

11

ELEK

TRA

Hea

tin

g M

ats

ELEKTRA MD Heating Mats are ready-to-install heating

elements which are produced in accordance with

UL 499, UL 1683, CSA C22.2#130. Consisting of a thin

heating cable attached to a self-adhesive glass fibre mesh,

the system is designed for indoor use and direct heating. It

should be installed directly under the surface to be heated,

in either flexible tile adhesive or self-levelling compound.

ELEKTRA Heating Mats

Power output: 9 and 14 W/ft (100 and 160 W/m )

Power supply: 120 and 240 V ~ 60 Hz

~ 1 6" (

Min. installation temperature: 23 F (–5 C)

Max. working temperature: 230 F (+110 C)

Conduit cables: 1 x 13 ft (1 x 4 m); 2 x 16 AWG or 2 x 18 AWG

~ "

Screen of heating cables: 100% coverage, tinned copper braiding

Power output of heating cable: ~ 2.5 W/ft (9 W/m) MD 100,

~ 4.0 W/ft (13 W/m) MD 160

FEP + XLPE

Outer sheath: PVDF

Protection: IPX7

2 2

Mat thickness: / 4 mm)

Type of heating cable: double-core of diameter 1/6 (4 mm),

single-side power supply

Insulation: double layer,

Rated power output tolerance: +5%, -10%

Min. radius of bending cable: 5 D

Product certificates: ETL

° °

° °

Technical data:>

Page 12: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

MD 100/1.0 120V 1.6 x 6.5 0.5 x 2.0 11.0 1.0 0.8 100MD 100/1.5 120V 1.6 x 10.0 0.5 x 3.0 16.0 1.5 1.2 150MD 100/2.0 120V 1.6 x 13.0 0.5 x 4.0 21.5 2.0 1.7 200MD 100/2.5 120V 1.6 x 16.5 0.5 x 5.0 27.0 2.5 2.1 250MD 100/3.0 120V 1.6 x 20.0 0.5 x 6.0 32.0 3.0 2.5 300MD 100/3.5 120V 1.6 x 23.0 0.5 x 7.0 37.5 3.5 2.9 350MD 100/4.0 120V 1.6 x 26.0 0.5 x 8.0 43.0 4.0 3.3 400MD 100/4.5 120V 1.6 x 29.5 0.5 x 9.0 48.5 4.5 3.7 450MD 100/5.0 120V 1.6 x 33.0 0.5 x 10.0 54.0 5.0 4.2 500MD 100/6.0 120V 1.6 x 39.5 0.5 x 12.0 64.5 6.0 5.0 600MD 100/8.0 120V 1.6 x 52.5 0.5 x 16.0 86.0 8.0 6.7 800MD 100/9.0 120V 1.6 x 59.0 0.5 x 18.0 97.0 9.0 7.5 900MD 100/10.0 120V 1.6 x 65.5 0.5 x 20.0 107.5 10.0 8.3 1000

120V 9 W/ft (100 W/m )2 2

ELEKTRA MD Heating Mats

Dimensions Coverage Amps Powerft x ft m x m ft m Amps Watts2 2

Model

MD 160/1.0 120V 1.6 x 6.5 0.5 x 2.0 11.0 1.0 1.3 160MD 160/1.5 120V 1.6 x 10.0 0.5 x 3.0 16.0 1.5 2.0 240MD 160/2.0 120V 1.6 x 13.0 0.5 x 4.0 21.5 2.0 2.7 320MD 160/2.5 120V 1.6 x 16.5 0.5 x 5.0 27.0 2.5 3.3 400MD 160/3.0 120V 1.6 x 20.0 0.5 x 6.0 32.5 3.0 4.0 480MD 160/3.5 120V 1.6 x 23.0 0.5 x 7.0 37.5 3.5 4.7 560MD 160/4.0 120V 1.6 x 26.0 0.5 x 8.0 43.0 4.0 5.3 640MD 160/4.5 120V 1.6 x 29.5 0.5 x 9.0 48.5 4.5 6.0 720MD 160/5.0 120V 1.6 x 33.0 0.5 x 10.0 54.0 5.0 6.7 800MD 160/6.0 120V 1.6 x 40.0 0.5 x 12.0 64.5 6.0 8.0 960MD 160/7.0 120V 1.6 x 46.0 0.5 x 14.0 75.5 7.0 9.3 1120MD 160/8.0 120V 1.6 x 52.5 0.5 x 16.0 86.0 8.0 10.7 1280

120V 14 W/ft (160W/m )2 2

Dimensions Coverage Amps Powerft x ft m x m ft m Amps Watts2 2

Model

MD 160/1.0 240V 1.6 x 6.5 0.5 x 2.0 11.0 1.0 0.7 160MD 160/1.5 240V 1.6 x 10.0 0.5 x 3.0 16.0 1.5 1.0 240MD 160/2.0 240V 1.6 x 13.0 0.5 x 4.0 21.5 2.0 1.3 320MD 160/2.5 240V 1.6 x 16.5 0.5 x 5.0 27.0 2.5 1.7 400MD 160/3.0 240V 1.6 x 20.0 0.5 x 6.0 32.0 3.0 2.0 480MD 160/3.5 240V 1.6 x 23.0 0.5 x 7.0 37.5 3.5 2.3 560MD 160/4.0 240V 1.6 x 26.0 0.5 x 8.0 43.0 4.0 2.7 640MD 160/4.5 240V 1.6 x 29.5 0.5 x 9.0 48.5 4.5 3.0 720MD 160/5.0 240V 1.6 x 33.0 0.5 x 10.0 54.0 5.0 3.3 800MD 160/6.0 240V 1.6 x 39.5 0.5 x 12.0 65.0 6.0 4.0 960MD 160/7.0 240V 1.6 x 46.0 0.5 x 14.0 75.0 7.0 4.7 1120MD 160/8.0 240V 1.6 x 52.0 0.5 x 16.0 86.0 8.0 5.3 1280MD 160/10.0 240V 1.6 x 66.0 0.5 x 20.0 107.5 10.0 6.7 1600

240V 14 W/ft (160 W/m )2 2

Dimensions Coverage Amps Powerft x ft m x m ft m Amps Watts2 2

Model

240V 9 W/ft (100 W/m )2 2

Dimensions Coverage Amps Power

MD 100/1.5 240V 1.6 x 10.0 0.5 x 3.0 16.0 1.5 0.6 150MD 100/2.0 240V 1.6 x 13.0 0.5 x 4.0 21.5 2.0 0.8 200MD 100/2.5 240V 1.6 x 16.5 0.5 x 5.0 27.0 2.5 1.0 250MD 100/3.0 240V 1.6 x 20.0 0.5 x 6.0 32.0 3.0 1.2 300MD 100/3.5 240V 1.6 x 23.0 0.5 x 7.0 37.5 3.5 1.5 350MD 100/4.0 240V 1.6 x 26.0 0.5 x 8.0 43.0 4.0 1.7 400MD 100/5.0 240V 1.6 x 33.0 0.5 x 10.0 54.0 5.0 2.1 500MD 100/6.0 240V 1.6 x 40.0 0.5 x 12.0 64.5 6.0 2.5 600MD 100/8.0 240V 1.6 x 52.0 0.5 x 16.0 86.0 8.0 3.3 800MD 100/10.0 240V 1.6 x 66.0 0.5 x 20.0 107.5 10.0 4.2 1000MD 100/12.0 240V 1.6 x 80.0 0.5 x 24.0 129.0 12.0 5.0 1200

ft x ft m x m ft m Amps Watts2 2Model

Accessories:>Thermostats: UWG4, UDG4

12

ELEK

TRA

Hea

tin

g M

ats

www.elektra.eu

Page 13: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

SnowTec®

This package contains:• ELEKTRA SnowTec heating mat,• instruction manual.

®

Technical data:>Power output: 32.5 W/ft (350 W/m )

~ 60 Hz

~ 9

Min. installation temperature: 23°F (–5°C)

Max. working temperature: 176°F (+80°C)

Conduit cables: 1 x 13 ft (1 x 4 m); 16 AWG or 18 AWG

~ x ( )

Outer sheath: LS0H

Protection: IPX7

2 2

Power supply: 240 V

Mat thickness: 1/3" ( mm)

Type of heating cable: double-core of diameter 1/5 1/3" 5.5 x 9 mm ,

single-side power supply

Screen of heating cables: 100% coverage, PET covered aluminum foil,

tinned copper braiding

Power output of heating cable: 10 W/ft (33 W/m)

Insulation: XLPE

Rated power output tolerance: +5%, -10%

Min. radius of bending cable: 5 D

Product certificates: ETL

ELEKTRA Heating Mats are ready-to-install heating

elements, composed of an ELEKTRA VCD heating cable

produced in accordance with UL 1588, CSA C22.2#130.

The cable is secured with unique tape in the mat shape.

This system is designed for outdoor use to protect against

snow and ice on driveways, walkways, ramps, etc.

SnowTec®

ELEKTRA Heating Mats

13

ELEK

TRA

Hea

tin

g M

ats

Page 14: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

Accessories:>Controllers: ETOG2

14

ELEK

TRA

Hea

tin

g M

ats

www.elektra.eu

240V 32.5 W/ft (350 W/m )2 2

ELEKTRA SnowTec Heating Mats®

Model Dimensions Coverage Amps Powerft x ft m x m ft m A W2 2

SnowTec 350/2 240V 2 x 6.5 0.6 x 2.0 13 1.2 1.8 440SnowTec 350/4 240V 2 x 13.0 0.6 x 4.0 26 2.4 3.7 880SnowTec 350/5 240V 2 x 16.5 0.6 x 5.0 33 3.0 4.5 1090SnowTec 350/7 240V 2 x 23.0 0.6 x 7.0 46 4.2 6.3 1520SnowTec 350/10 240V 2 x 33.0 0.6 x 10.0 66 6.0 8.8 2100SnowTec 350/13 240V 2 x 42.5 0.6 x 13.0 85 7.8 11.5 2770SnowTec 350/16 240V 2 x 52.5 0.6 x 16.0 105 9.6 14.0 3350SnowTec 350/20 240V 2 x 65.5 0.6 x 20.0 131 12.0 17.9 4300SnowTec 350/25 240V 2 x 82.0 0.6 x 25.0 164 15.0 21.9 5250

®

®

®

®

®

®

®

®

®

Page 15: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

UltraTec

Technical data:>Power output: 3 W/ft (10 W/m)

Power supply: 120 and 240 V ~ 60 Hz

External dimension of cable: 1/10 1/7 mm

Min. installation temperature: ° °

Max. working temperature: ° +105°C)

Conduit cables: 1 x 8 ft (1 x 2.5 m); 2 x 16 AWG or 2 x 18 AWG

Type of heating cable: double-core, single-side power supply

Screen of heating cables: 100% coverage, tinned copper braiding

Insulation: FEP

Outer sheath: PVDF

Rated power output tolerance: +5%, -10%

Min. radius of bending cable: 5 D

Protection: IPX8

Product certificates: ETL

~ x " (2.5 x 3.5 )

23 F (–5 C)

230 F (

ELEKTRA UltraTec Heating Cables are ready-to-install heating

units which are produced in accordance with UL 499, UL 1683,

CSA C22.2#130. They consist of an ultra-thin, high tempera-

ture resistant cable, terminated with a cold tail. This system

is designed for indoor use and direct heating. It should be

installed directly under the surface to be heated, in either

flexible tile adhesive or self-levelling compound.

ELEKTRA Heating Cables

15

ELEK

TRA

Hea

tin

g C

able

s

This package contains:• ELEKTRA heating cable (on a spool),• self-adhesive installation tape,

• instruction manual,• wraning labels.

• 'cold tails' flexible conduit,• flexible conduit for the temperature

sensor, capped on one end,

Page 16: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

Accessories:>Thermostats: UWG4, UDG4

16

ELEK

TRA

Hea

tin

g C

able

swww.elektra.eu

UltraTec 10/70 120V 23.0 7.0 5-8 0.6 70UltraTec 10/120 120V 37.5 12.0 6-9 1.0 120UltraTec 10/150 120V 47.5 14.5 8-13 1.3 150UltraTec 10/210 120V 69.0 21.0 15-23 1.8 210UltraTec 10/235 120V 77.0 23.5 17-26 2.0 235UltraTec 10/290 120V 95.0 29.0 21-32 2.4 290UltraTec 10/360 120V 120.0 36.5 26-40 3.0 360UltraTec 10/410 120V 133.0 40.5 29-46 3.4 410UltraTec 10/450 120V 149.0 45.5 32-50 3.8 450UltraTec 10/510 120V 169.0 51.5 36-57 4.3 510UltraTec 10/570 120V 188.5 57.5 41-63 4.8 570UltraTec 10/690 120V 226.5 69.0 49-77 5.8 690UltraTec 10/860 120V 280.5 85.5 61-96 7.2 860UltraTec 10/1070 120V 354.5 108.0 76-119 8.9 1070

240V 3 W/ft (10 W/m)120V 3 W/ft (10 W/m)

ELEKTRA UltraTec Heating Cables

Modelft m ft Amps Watts2

Length Coverage Amps PowerModel

ft m ft Amps Watts2

Length Coverage Amps Power

UltraTec 10/150 240V 51.0 15.5 11-17 0.7 150UltraTec 10/230 240V 77.0 23.5 16-26 1.0 230UltraTec 10/295 240V 98.5 30.0 21-33 1.2 295UltraTec 10/330 240V 110.0 33.5 24-37 1.4 330UltraTec 10/420 240V 136.0 41.5 30-47 1.8 420UltraTec 10/470 240V 154.0 47.0 34-52 2.0 470UltraTec 10/575 240V 190.0 58.0 41-64 2.4 575UltraTec 10/725 240V 238.0 72.5 52-81 3.0 725UltraTec 10/815 240V 267.5 81.5 58-91 3.4 815UltraTec 10/910 240V 295.0 90.0 65-101 3.8 910UltraTec 10/1020 240V 336.0 102.5 73-113 4.3 1020UltraTec 10/1140 240V 376.0 114.5 81-127 4.8 1140UltraTec 10/1380 240V 451.0 137.5 99-153 5.8 1380UltraTec 10/1720 240V 561.0 171.0 123-191 7.2 1720UltraTec 10/2140 240V 705.5 215.0 153-238 9.0 2140

Page 17: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

DM

ELEKTRA Heating Cables

Technical data:>

ELEKTRA DM Heating Cables are ready-to-install heating units

which are produced in accordance with UL 499, UL 1683, CSA

C22.2#130. A thin heating cable of the length depending on

the model, has factory connected cold tail cable. This system is

designed for indoor use and direct heating. It should be

installed directly under the surface to be heated, in either

flexible tile adhesive or self-levelling compound.

This package contains:• ELEKTRA heating cable (on a spool),• self-adhesive installation tape,

• instruction manual,• warning labels.

• 'cold tails' flexible conduit,• flexible conduit for the temperature

sensor, capped on one end,

17

ELEK

TRA

Hea

tin

g C

able

s

Power output: 3 W/ft (10 W/m)

Power supply: 120 and 240 V ~ 60 Hz

External dimension of cable: /

Min. installation temperature: ° °

Max. working temperature: ° °

Conduit cables: 1 x 8 ft (1 x 2.5 m); 2 x 16 AWG or 2 x 18 AWG

Type of heating cable: double-core, single-side power supply

Screen of heating cables: 100% coverage, tinned copper braiding

Insulation: FEP

Outer sheath: PVDF

Rated power output tolerance: +5%, -10%

Min. radius of bending cable: 5 D

Protection: IPX8

Product certificates: ETL

~ 1 6" (4 mm)

23 F (–5 C)

221 F (+105 C)

Page 18: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

Accessories:>Thermostats: UWG4, UDG4

18

ELEK

TRA

Hea

tin

g C

able

swww.elektra.eu

DM 10/150 240V 51.0 15.5 11-17 0.7 150DM 10/230 240V 77.0 23.5 16-26 1.0 230DM 10/295 240V 98.5 30.0 21-33 1.2 295DM 10/330 240V 110.0 33.5 24-37 1.4 330DM 10/420 240V 136.0 41.5 30-47 1.8 420DM 10/470 240V 154.0 47.0 34-52 2.0 470DM 10/575 240V 190.0 58.0 41-64 2.4 575DM 10/725 240V 238.0 72.5 52-81 3.0 725DM 10/815 240V 267.5 81.5 58-91 3.4 815DM 10/910 240V 295.0 90.0 65-101 3.8 910DM 10/1020 240V 336.0 102.5 73-113 4.3 1020DM 10/1140 240V 376.0 114.5 81-127 4.8 1140DM 10/1380 240V 451.0 137.5 99-153 5.8 1380DM 10/1720 240V 561.0 171.0 123-191 7.2 1720DM 10/2140 240V 705.5 215.0 153-238 9.0 2140

DM 10/70 120V 23.0 7.0 5-8 0.6 70DM 10/120 120V 37.5 12.0 6-9 1.0 120DM 10/150 120V 47.5 14.5 8-13 1.3 150DM 10/210 120V 69.0 21.0 15-23 1.8 210DM 10/235 120V 77.0 23.5 17-26 2.0 235DM 10/290 120V 95.0 29.0 21-32 2.4 290DM 10/360 120V 120.0 36.5 26-40 3.0 360DM 10/410 120V 133.0 40.5 29-46 3.4 410DM 10/450 120V 149.0 45.5 32-50 3.8 450DM 10/510 120V 169.0 51.5 36-57 4.3 510DM 10/570 120V 188.5 57.5 41-63 4.8 570DM 10/690 120V 226.5 69.0 49-77 5.8 690DM 10/860 120V 280.5 85.5 61-96 7.2 860DM 10/1070 120V 354.5 108.0 76-119 8.9 1070

240V 3 W/ft (10 W/m)120V 3 W/ft (10 W/m)

ELEKTRA DM Heating Cables

Length Coverage Amps Powerft m ft Amps Watts2ft m ft Amps Watts2

Length Coverage Amps PowerModelModel

Page 19: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

VCD25

ELEKTRA Heating Cables

Technical data:>Power output: 7.5 W/ft (25 W/m)

4 ~ 60 Hz

~

Min. installation temperature: ° °

Max. working temperature: 176° +80°C)

Conduit cables: 1 x 8 ft (1 x 2.5 m), 16 AWG or 18 AWG

Screen of heating cables: 100% coverage, PET covered aluminum foil,

tinned copper braiding

Outer sheath: LS0H

Protection: IPX7

Power supply: 2 0 V

External dimension of cable: 1/5 x 1/3 in (5.5 x 9.0 mm)

Type of heating cable: double-core, single-side power supply

Insulation: XLPE

Rated power output tolerance: +5%, -10%

Min. radius of bending cable: 3.5 D

Product certificates: ETL

23 F (–5 C)

F (

ELEKTRA VCD25 Heating Cables are ready-to-install heating

units which are produced in accordance with UL 1588, CSA

C22.2#130. Heating cable of the length depending on the

model, has factory connected cold tail cable. Protection

against snow and ice of external surfaces e.g. driveways,

walkways, ramps, etc.

This package contains:• ELEKTRA heating cable (on a spool),• instruction manual,• warning labels.

19

ELEK

TRA

Hea

tin

g C

able

s

Page 20: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

Controllers: ETOG2

Installation accessories: page 21

Accessories:>

20

ELEK

TRA

Hea

tin

g C

able

swww.elektra.eu

ELEKTRA Heating CablesVCD25240V 7.5 W/ft (25 W/m)

ft m ft A W2

Length Coverage Amps PowerModel

VCD 25/150 240V 20 6.0 3 - 8 0.6 150VCD 25/215 240V 30 9.0 5 - 12 0.9 215VCD 25/335 240V 43 13.0 7 - 18 1.4 335VCD 25/385 240V 51 15.5 8 - 21 1.6 385VCD 25/430 240V 59 18.0 9 - 23 1.8 430VCD 25/520 240V 69 21.0 11 - 28 2.2 520VCD 25/605 240V 79 24.0 13 - 33 2.5 605VCD 25/690 240V 90 27.5 15 - 37 2.9 690VCD 25/770 240V 98 30.0 17 - 41 3.2 770VCD 25/935 240V 123 37.5 20 - 50 3.9 935VCD 25/1160 240V 151 46.0 25 - 62 4.8 1 160VCD 25/1320 240V 174 53.0 28 - 71 5.5 1 320VCD 25/1520 240V 197 60.0 33 - 82 6.3 1 520VCD 25/1820 240V 239 73.0 39 - 98 7.6 1 820VCD 25/2010 240V 262 80.0 43 - 108 8.4 2 010VCD 25/2380 240V 313 95.5 51 - 128 9.9 2 380VCD 25/2570 240V 338 103.0 55 - 138 10.7 2 570VCD 25/2860 240V 377 115.0 62 - 154 11.9 2 860VCD 25/3160 240V 413 126.0 68 - 170 13.2 3 160VCD 25/3480 240V 456 139.0 75 - 187 14.5 3 480VCD 25/3710 240V 489 149.0 80 - 200 15.5 3 710VCD 25/4050 240V 531 162.0 87 - 218 16.9 4 050VCD 25/4550 240V 597 182.0 98 - 245 19.0 4 550VCD 25/5570 240V 731 223.0 200 - 300 23.2 5 570

Page 21: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

Installation TapesTME 10 33 ft (10 m)TME 15 49 ft (15 m)TME 25 82 ft (25 m)

Installation TapeTMS 10 32 ft (10 m)

ELEKTRA InstallationAccessories

Thickness: 0.03" (0.8 mm)Substance: aluminium

~

Thickness: 0.04" ( 0 mm)Substance: zinc-coated steel

~ 1.

21

ELEK

TRA

Inst

alla

tio

n A

cces

sori

es

Installation monitorUH-IMMonitoring device for detection of damages occurringduring heating mats and cables’ installation

Page 22: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

The ELEKTRA UWG4 thermostat is designed for heating

systems, especially electric floor heating. Touch thermostat for

radiant floor heating with sleek design and intuitive control

designed for easy installation plus WiFi connectivity for remote

control gives users convenient, easy-to-use access to adjusting

and monitoring their home heating system from any location.

WiFi connectivity also gives easy access to information on

energy consumption and system performance. Equipped with

a 3.5-inch colour touch-screen. Compatible with most

commercially available floor sensors.

ELEKTRA Thermostats

Power supply: 120-240 V ~ 50/60 Hz

Max. load: 15A

Temperature range: +41°F to +104°F (+5°C to +40°C)

Floor limit range: +41°F to +104°F (+5°C to +40°C)

Protection: IP20

Dimensions (H x W x D): 5.1 x 3.2 x 0.8" (130 x 82 x 20 mm)

Wall box (H x W x D): 3 x 2 x 2"

Display: Touch, 3½", 65k color

Wireless control: WiFi (cloud)

Applications: Android, iOS

Programmable event: 1-6 per day

Ground Fault Protection (GFCI): Class A (5 mA)

Certificates: cUL

Technical data:>

22

ELEK

TRA

Th

erm

ost

ats

www.elektra.eu

Programmable touchUWG4 WiFi

This package contains:• UWG4 thermostat,• a thin floor temperature sensor

with 9 ft (3 m) tail (ETF-144/99T),• instruction manual.

ETF-144/99T

Page 23: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

This package contains:• UDG4 thermostat,• a thin floor temperature sensor

with 9 ft (3 m) tail (ETF-144/99T),• instruction manual.

The ELEKTRA UDG4 thermostat is designed for heating

systems, especially electric floor heating. It can be configured

for control of floor temperature, room temperature, or room

temperature with limit switch, and regulator without sensor.

Equipped with a 3.5-inch colour touch-screen.

Compatible with most commercially available floor sensors.

Application of the QR code enables fast preview of the

controller's settings in your smartphone.

23

ELEK

TRA

Th

erm

ost

ats

Power supply: 120-240 V ~ 50/60 Hz

Max. load: 15A

Temperature range: +41°F to +104°F (+5°C to +40°C)

Floor limit range: +41°F to +104°F (+5°C to +40°C)

Protection: IP20

Dimensions (H x W x D): 5.1 x 3.2 x 0.8" (130 x 82 x 20 mm)

Wall box (H x W x D): 3 x 2 x 2"

Display: Touch, 3½", 65k color

Programmable event: 1-6 per day

Ground Fault Protection (GFCI): Class A (5 mA)

Certificates: cUL

Technical data:>

Programmable touchUDG4ELEKTRA Thermostats

ETF-144/99T

Page 24: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

The ELEKTRA ETOG2 controller is designed especially for

snow and ice protection electric heating systems. It consists

of a controller and a ground humidity detector with an

integrated air temperature sensor. ETOG2 controls up to 2

zones or a single zone by means of 2 sensors. It is a solution

even for large applications, e.g. car parks or driveways.

The controller features the possibility to cooperate

analogously with a BMS system via a relay informing about

the alarm status and two pairs of connectors enabling

manual switch on or stand-by of the heating system from

the BMS.

ELEKTRA Controllers

ETO2-4550

ETOG-56T

Power supply: 115/240 V

Built-in transformer: 24VAC, 6VA

Max. load: 3 x 16A (potential free relays)

Installation: DIN-rail or surface mounting

Temperature range: -68°F ÷ +122°F (

Difference/Hysteresis: 0.3K

Controller cover protection

Work signalization: LED

Temperature sensor calibration: potentiometer

Working temperature: 32°F ÷ +122°F (

Dimensions (H x W x D): 3.5 x 6.1 x 1.8" (90 x 156 x 45 mm)

Modules: 9

Installation: in the ground

Cover protection: IP 68

Dimensions (H x D): 1.2 x 2.4" (30 x 60 mm)

Measurement: humidity and ground temperature

~ 60 Hz

-20°C ÷ +50°C)

(surface mounting): IP 21

0°C ÷ +50°C)

Certificates: CSA

Working temperature: -122°F ÷ +158°F (-50°C ÷ +70°C)

Technical data:>

DIN-rail ETOG2

This package contains:Type ETOG2• ETO2-4550 controller,• humidity detector with an integral

temperature sensor (ETOG-56T),• ETOK-T installation tube

for ETOG-56T sensor,• cover for surface mounting,• instruction manual.

ETOG-56T ETOK-T

Surfacemounting box

24

ELEK

TRA

Co

ntr

olle

rswww.elektra.eu

Page 25: electric heating systems - Elektra · • ELEKTRA heating mat, • 'cold tails' flexible conduit, • flexible conduit for the temperature sensor, capped on one end, • instruction

ELEKTRAul. K. Kamińskiego 4, 05-850 Ożarów Mazowiecki, Polandphone +48 22 843 32 82e-mail: [email protected] www.elektra.eu Edition 12/2019

ES

G (U

S) 3

00G

rup

a V

512

/19

0 A

4 (1

) b