Top Banner
Series ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L: Large flow type Ejectors and solenoid valves can be mounted on the same manifold. Centralized wiring of ejector (ZYX3000: Individual pressure switch not included) 1055 ZK2 ZQ ZR ZA ZX ZM ZMA ZL ZH ZU ZYY ZYX
43

Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

May 06, 2018

Download

Documents

trinhdien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

Series ZYY3000(Solenoid valve: SY3000)

Series ZYX3000(Solenoid valve: SX3000)

Series ZYY/ZYXEjector Valve Unit

Nozzle diameter: ø0.7, ø1.0Type S: Standard type L: Large flow type

Ejectors and solenoid valves can be mounted on the same manifold.Centralized wiring of ejector

(ZYX3000: Individual pressure switch not included)

1055

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 2: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

How to Order Ejector Valves for ZYY3000

Without light/surge voltage suppressorWith surge voltage suppressorWith light/surge voltage suppressorWith surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)

NilSZRU

Light/Surge voltage suppressor

NPN open collector 1 output,without analog output, 3 turn setting

NPN open collector 1 output,without analog output, 200 degree setting

NPN open collector 2 outputs,without analog output, 3 turn setting

NPN open collector 2 outputs,without analog output, 200 degree setting

NPN open collector 1 output,with analog output, 3 turn setting

NPN open collector 1 output,with analog output, 200 degree setting

PNP open collector 1 output,without analog output, 200 degree setting

14

15

16

17

18

19

55

Output specifications(Vacuum pressure switch)

10Y3ZY

Rated voltage

Y3SeriesSY3000

56VSR

24 VDC12 VDC6 VDC5 VDC3 VDC

Wiring specifications(Vacuum pressure switch)

S 15

GHL

LNLOM

MNMO

Electrical entry

Lead wire length 300 mmLead wire length 600 mmWith lead wires (Length 300 mm)Without lead wires Without connectorWith lead wires (Length 300 mm)Without lead wires Without connector

Grommet

L plugconnector

M plugconnector

Nozzle diameter

Manual override

NoneWith vacuum pressure switch

NilE

Vacuum pressure switch

With manifold blockNone

NilMN

Manifold block

Connector box typeLOU

Lead wire/Voltage suppressor specifications

NoneWith silencer

Nil1

Silencer

–84 kPa–53 kPa

SL

0.71.0

0710

Non-locking push typePush-turn locking slotted typePush-turn locking lever type

NilDE

Max. vacuum pressure

L Z5 LOU

For electrical entry types G, H, L, M

1234

100 VAC200 VAC

110 VAC [115VAC]220 VAC [230VAC]

DC specifications

AC specifications (50/60 Hz)

24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC

NilLC

CLCN

Lead wire length 0.6 mLead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

Grommettype

Connectortype

Note) The connector box type and serial transmission type are only available with 5 (24 VDC).

Types LN and MN are equipped with sockets (2 pcs.).Not compatible with the FU electrical entry which is used on Series SY3000 plug-in type manifolds (45F, 45P, 45T, 45T1, 45S, 45S1, 45S2, 45S3).

Note 1)

Note 2)

Types R and U are DC only.Since surge voltage is prevented with a rectifier in the case of AC, there is no type “S”.

Note 1)Note 2)

Ejector Valve Unit

Series ZYY/ZYX

1056

Page 3: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

M

Without light/surge voltage suppressorWith surge voltage suppressorWith light/surge voltage suppressor

NilSZ

Light/Surge voltage suppressor

NPN open collector 1 output,without analog output, 3 turn setting

NPN open collector 1 output,without analog output, 200 degree setting

NPN open collector 2 outputs,without analog output, 3 turn setting

NPN open collector 2 outputs,without analog output, 200 degree setting

NPN open collector 1 output,with analog output, 3 turn setting

NPN open collector 1 output,with analog output, 200 degree setting

PNP open collector 1 output,with analog output, 200 degree setting

14

15

16

17

18

19

55

Output specifications(Vacuum pressure switch)

10X3ZY

Rated voltage

X3Series SX3000

NilN

Common specificationsPositive commonNegative common

56VSR

24 VDC12 VDC6 VDC5 VDC3 VDC

Wiring specifications(Vacuum pressure switch)

S 15

GHL

LNLOM

MNMO

Electrical entryLead wire length 300 mmLead wire length 600 mmWith lead wires (Length 300 mm)Without lead wiresWithout connectorWith lead wires (Length 300 mm)Without lead wires Without connector

Grommet

L plugconnector

M plugconnector

Nozzle diameter

Manual override

NoneWith silencer

NilE

Vacuum pressure switch

Plug-in typeNon plug-in type

NilF

Plug-in/Non plug-in type

With manifold blockNone

NilMN

Manifold block

NoneWith vacuum pressure switch

Nil1

Silencer

–84 kPa–53 kPa

SL

0.71.0

0710

Non-locking push typePush-turn locking slotted type

NilD

Max. vacuum pressure

5 M Z

For electrical entry types G, H, L, M

DC specifications

NilLC

CLCN

Lead wire length 0.6 mLead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

Grommettype

Connectortype

Plug-in typeSerial transmission type

LOZ

Lead wire/Voltage suppressor specifications

How to Order Ejector Valves for ZYX3000

LOZ

Note 1) The serial transmis-sion type is 5 (24 VDC) only.

Note 2) V, S and R specifica-tions are 45T, 45T1.

Note 1) The symbol is “Nil” for the single grommet type and when not equipped with light/surge voltage suppressor.

Note 2) Match with the common specification of the manifold.

Note) For types LN and MN, the single solenoid has 2 sockets and the double solenoid has 3 sockets.

Ejector Valve Unit Series ZYY/ZYX

1057

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 4: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

For solenoid valve and ejector valve combination

For ejector valves only(Without solenoid valves: individual wiring type is compliant only.)

Y 3X 3SS5 45

Y 3X 3ZZY

Change to ZZYEjector valvenumbers

45 J 1 U

With ejector

Number of ejectors1 to 10

Ejector mounting position

JZZY 1 U

With ejector

Number of ejectors1 to 10

Example) ZYY-J3U

∗ ZYY35MZ-10S1-E15C∗ ZYY35MZ-10S1

2SETS1SET

1SET

[Example: When individual wiring type model 45 for SY3000 is selected]

ZZY Y3-45-04D-C6-SY3000 manifold model Ejector valve

numbers

J1U 1SET

∗ SX3000-75-1A∗ SY3140-5LZ∗ SY3240-5LZ∗ ZYY35LZ-10S-E15C

1SET1SET1SET1SET

UD

U sideD side

Note 1)

However, (optional DIN rail) is a special order specification.

SY3000/SX3000Same as ordering manifold.

Enter the following together with the manifold number:

1. Part no. of solenoid for SY3000/SX30002. Part no. of ejector valve for ZYY3000/ZYX3000.

∗ is the symbol for a built-in assembly. Add the ∗ symbol at the beginning of part numbers for solenoid valves, etc. to be mounted, and enter these together in order from the D side.

∗ When ordering manifold valve components individually without adding the ∗ symbol, add -MN at the end of the ejector valve numbers.

Note 1) Varies according to the total number of solenoid valve and ejector valve stations. Refer to pages 1074 to 1095 for the Manifold Valve Specifica-tion Sheet.

Series ZYY/ZYX

How to Order Manifold Valves for ZYY3000/ZYX3000 (Split Base/DIN Rail Mounting)

Ejector valveZYY35LZ-10S-E15C-MN

Double solenoid (24 VDC)SY3240-5LZ

Single solenoid (24 VDC)SY3140-5LZ

Blanking plate assemblySX3000-75-1A

Cylinder port sizeC6 : With ø6 One-touch fittingManifold base (4 stations)ZZYY3-45-04D-C6-J1U

U side

Stations····3 2 1

D side

1058

Page 5: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

Series ZYY3000

Series ZYX3000

Ejector Valve Specifications

Supply/Release Valve Specifications

ZY3–07S

0.7 1.0

0.6 MPa

0.45 MPa

5 to 50°C

ZY3–07L ZY3–10S ZY3–10L

11

–84

18

–53

22

–84

32

–53

Valve type

Type of actuation

Fluid

Operating pressure range

Ambient and fluid temperature

Allowable voltage fluctuation

Electrical entry

Power consumption

Effective area (Cv factor)

Pilot type 3 position 3 port solenoid valve

Closed center

Air

0.2 to 0.6 MPa

5 to 50°C

–10 to +10%

Grommet : G, H L plug connector: L, LN, LO

M plug connector: M, MN, MO

0.5 W (With indicator light: 0.6 W): Series ZYY3000

0.6 W (With indicator light: 0.65 W): Series ZYX3000

4.68 mm2 (0.26)

Ejector valve model

Nozzle diameter (mm)

Max. suction flow rate N (L/min (ANR))

Max. vacuum pressure (kPa)

Maximum operating pressure

Standard supply pressure

Operating temperature range

Series SY3000/SX3000 in manifold/split base combinations DIN rail mount type can be mounted

Compact (integrated construction of ejector and valve)Copper-free and fluorine-free measures implemented

Ejector Valve Unit Series ZYY/ZYX

1059

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 6: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

Sensor type

Set pressure range

Hysteresis

Repeatability

Temperature characteristics

Operating voltage

ZSE1– 00 –14–X129 (–X130)

ZSE1– 00 –15–X129 (–X130)

ZSE1– 00 –16–X129 (–X130)

ZSE1– 00 –17–X129 (–X130)

ZSE1– 00 –18–X129 (–X130)

ZSE1– 00 –19–X129 (–X130)

ZSE1– 00 –55–X129 (–X130)

Diffusion type semiconductor pressure sensor

0 to –101 kPa

±1% full span or less

±3% full span or less

12 to 24 VDC (Ripple ±10% or less)

PNP opencollector

Max. 80 mANPN open collector 30 V Max. 80 mA

Lights up when ON (Red) Lights up when ON (Red)Lights up when ON

(OUT1: Red, OUT2: Green)

None

1 point

3 turns 200 degrees 3 turns 200 degrees 3 turns 200 degrees 200 degrees

1 point2 point

None1 to 5 V

1 to –10% of set pressure (Adjustable)

17 mA or less (When 24 VDC is ON) 25 mA or less (When 24 VDC is ON)

0.2 MPa

17 mA or less (When 24 VDC is ON)

1 to –10% of set pressure (Adjustable)3% full span or less (Fixed)

Model

ON-OFF output

Operationindicator light

Setting trimmerrotation angle

Analog output

Setting points

Current consumption

Max. operating pressure

Electronic Vacuum Pressure Switch Specifications

Note 1) When using an ejector, there is no problem if pressure of 0.5 MPa is applied for 1 second or less.Note 2) X129 is for Series ZYX3000 and X130 is for Series ZYY3000.Note 3) For details about wiring, refer to the Operation Manual that can be downloaded from SMC website (http://www.smcworld.com).

Series ZYY/ZYX

1060

Page 7: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

How to Set the Pressure How to Use the Connector1. Attaching and detaching connectors

Hysteresis

ZSE1--14/-15/-18/-19

ZSE1--16/-172. Crimping of lead wire and socket

Connector

Lead wire

Socket

Hook

+21–

• When using to confirm adsorption, set to the minimum vacuum pressure at which adsorption is possible. If set below this valve, the switch will turn ON even when adsorption has failed or is insufficient. Also take note that if the setting is too high, the switch may not turn ON even with good adsorption.

Strip 3.2 to 3.7 mm at the end of the wire, place the exposed core wire into the socket properly and crimp with a crimping tool. When this is done, be sure that the lead wire covering does not get into the core wire crimping area. (Crimping tool: Model DXT170-75-1)

• AttachingInsert the sockets into the square holes of the connector (with +, 1, 2, – indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires.

• DetachingTo detach a socket from a connector, pull out the lead wire while pressing the socket’s hook with a stick having a thin tip (about 1 mm). If the socket will be used again, first spread the hook outward.

• To install the connector, hold the lever and connector unit between your fingers and insert it straight onto the pins. Then lock it by pressing the pawl of the lever into the slot on the housing.

• To remove the connector, pull it straight out while pressing the lever down with your thumb to release the pawl from the slot.

Hysteresis is the difference between the pressure at which the output signal turns ON and the pressure at which it turns OFF. It turns ON at the set pressure.

• The ON pressure is set with the pressure setting trimmer. High vacuum settings are obtained by turning it clockwise.

• When setting, use a flat head screw driver which fits the slot in the trimmer, and turn it gently with your finger tips.

• Hysteresis can be set using the hysteresis setting trimmer. The setting is increased by turning it clockwise, and the range is 1 to 10% of the ON pressure.

• When the hysteresis setting trimmer is moved after setting the ON pressure, it must be set again.

• OUT1 (white lead wire, red LED) can be set with pressure setting trimmer 1 (SET1).

• OUT2 (green lead wire, green LED) can be set with pressure setting trimmer 2 (SET2).

Ejector Valve Unit Series ZYY/ZYX

Set pressure

High

vacu

um

Hyste

resis ON

OFF

High p

ressur

e

Set pressure

Set pressure

Supply pressure

Atmosphericpressure

0

Hig

h va

cuum

Unstableadsorption

No adsorption

Reliable adsorption

Atmosphericpressure 0

3. Attaching and detaching of socket to connector with lead wire

Lead wireSocket

Covering retainerCore wire crimping area

Hook Covering

Core wire

Lead wire

Socket

ConnectorDC polarity indication

Lever

Hook

Hook

Lead wireSocket

ConnectorDC polarity indicationLeverPinSlotHousing

0.2 to 0.33 mm2

Max. covering dia.ø1.7 mm

0.2 to 0.33 mm2

Max. covering dia.ø1.7 mm

Hysteresis setting trimmer

Pressure setting trimmer

SET

HYSIndicator light

Indicator light SET2

SET1

Pressure setting trimmer 1

Pressure setting trimmer 2

1061

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 8: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

BB

AA

V

!0!1 r t

e

!2

!3

i w u

q

y

o

Construction

ZYY3000

Section A-A' (Ejector)

Section B-B' (Solenoid valve)

Component PartsNo.

1

2

3

4

5

6

7

8

Description Material

Resin

Zinc die-casted

Resin

Aluminum alloy

Aluminum alloy

Stainless steel

Aluminum alloy

Resin

Note

Manifold block

Body

Silencer cover

Nozzle

Diffuser

Needle

Spool

Piston

Replacement PartsNo.

9

10

11

12

13

Description Part no.

3 port solenoid valve

Vacuum pressure switch

End plate assembly

Silencer

Non plug assembly

SY114-

For without a switch

AN15-C08

ZYY3000-NPA

Series ZYY/ZYX

1062

Page 9: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

B B

AA

BA

EXH.

V

P1

BA

B

A

o!0 r t

e

!1

w u

i

y

q

!2

Construction

ZYX3000

Section A-A' (Ejector)

Section B-B' (Solenoid valve)

Component PartsNo.

1

2

3

4

5

6

7

8

Description Material

Resin

Zinc die-casted

Resin

Aluminum alloy

Aluminum alloy

Stainless steel

Aluminum alloy

Resin

Note

Manifold block

Body

Silencer cover

Nozzle

Diffuser

Needle

Spool

Piston

Replacement PartsNo.

9

10

11

12

Description Part no.

Vacuum pressure switch

End plate assembly

Silencer

Plug assembly

For without a switch

AN15-C08

ZYY3000-PA

Ejector Valve Unit Series ZYY/ZYX

1063

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 10: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

-100

-80

-60

-40

-20

0

50

40

30

20

10

0

0 0.1 0.2 0.3 0.4 0.5 0.6

-100

-80

-60

-40

-20

0

0 10 20

-100

-80

-60

-40

-20

0

50

40

30

20

10

0

0 0.1 0.2 0.3 0.4 0.5 0.6

-100

-80

-60

-40

-20

0

0 5 10 15 20 25

-100

-80

-60

-40

-20

0

60

40

20

0

0 0.1 0.2 0.3 0.4 0.5 0.6

-100

-80

-60

-40

-20

0

0

-100

-80

-60

-40

-20

0

60

40

20

0

0 0.1 0.2 0.3 0.4 0.5 0.6

-100

-80

-60

-40

-20

0

0 10 20 30 40 505 10 15 20 25

Supply pressure (MPa) Suction flow rate (L/min(ANR))

Vac

uum

pre

ssur

e (k

Pa)

Vac

uum

pre

ssur

e (k

Pa)

Suc

tion

flow

rat

e (L

/min

(AN

R))

Air

cons

umpt

ion

flow

rat

e (L

/min

(AN

R))

Supply pressure (MPa) Suction flow rate (L/min(ANR))

Vac

uum

pre

ssur

e (k

Pa)

Vac

uum

pre

ssur

e (k

Pa)

Suc

tion

flow

rat

e (L

/min

(AN

R))

Air

cons

umpt

ion

flow

rat

e (L

/min

(AN

R))

Supply pressure (MPa) Suction flow rate (L/min(ANR))

Vac

uum

pre

ssur

e (k

Pa)

Vac

uum

pre

ssur

e (k

Pa)

Suc

tion

flow

rat

e (L

/min

(AN

R))

Air

cons

umpt

ion

flow

rat

e (L

/min

(AN

R))

Vacuum pressure

Vacuum pressure

Vacuum pressure

Vacuum pressure

Air consumption Air consumption

Air consumption

Air consumption

Suction flow rate

Suction flow rate

Suction flow rate

Suction flow rate

Supply pressure (MPa) Suction flow rate (L/min(ANR))

Vac

uum

pre

ssur

e (k

Pa)

Vac

uum

pre

ssur

e (k

Pa)

Suc

tion

flow

rat

e (L

/min

(AN

R))

Air

cons

umpt

ion

flow

rat

e (L

/min

(AN

R))

Q1

P1

Qmax

Pmax

Suction flow rate

Vac

uum

pre

ssur

e

Exhaust Characteristics/Flow Characteristics

ZY -07SExhaust Characteristics Flow Characteristics Exhaust Characteristics Flow Characteristics

Exhaust Characteristics Flow Characteristics Exhaust Characteristics Flow Characteristics

The flow rate characteristics correspond to a supply pressure of 0.45 MPa.

Y3X3 ZY -07L

Y3X3

ZY -10SY3X3 ZY -10L

Y3X3

How to Read Flow Characteristics Graph

The flow rate characteristics indicate the relationship between the vacuum pressure and the suction flow rate of the ejector, and show that when the suction flow rate changes the vacuum pressure also changes. In general, this indicates the relationship at the ejector,s standard operating pressure. In the graph, Pmax indicates the maximum vacuum pressure, and Qmax indicates the maximum suction flow rate. These are the values that are published as specifications in catalogs, etc. The methods for changing the vacuum pressure will be explained in order.1. If the ejector’s suction port is closed and sealed tight, the suction flow rate becomes “0”

and the vacuum pressure increases to the maximum (Pmax). 2. If the suction port is opened gradually and air is allowed to flow (the air leaks), the inlet

flow rate increases and the vacuum pressure decreases. (the condition of P1 and Q1)3. If the suction port is opened completely, the suction flow rate increases to the maximum

(Qmax), while the vacuum pressure then drops almost to “0” (atmospheric pressure). In this way, when the suction flow rate changes the vacuum pressure also changes. In other words, when there is no leakage at the vacuum port (vacuum piping), the vacuum pressure increases to the maximum, but the vacuum pressure drops as the amount of leakage increases, and when the amount of leakage and the maximum suction flow rate become equal, the vacuum pressure decreases nearly to “0”. When adsorbing workpieces which are permeable or subject to leakage, etc., caution is required as the vacuum pressure will not be very high.

Series ZYY/ZYX

1064

Page 11: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

P

P

P

Vacuum switch(With analog output)

P

Vacuum switch(Without analog output)

Silencer

Supply/Release valve

V

P1

Release flow rate adjusting needle

Ejector unit

(Lead wire length)

333.8

139Approx. 600

Indicator light (Red)

≅300117

55.516.5

13.5

5.25

1.4

41.649

.4

43.1

(8.25) (13.5)

58.6

67 35.3

28.5

33.6

62.1

10

2129.543

.1

(33.3)

23.5

27

(5.25)

18.8

16.8

117

55.516.5

Vacuum switch

Manual override

Manual override

Pressure setting trimmer

Hysteresis setting trimmer

Manual override

Pilot valve for supply valve

Button for block separation

Pilot valve for release valve

Release flow rateadjusting needle

Manual override

Pilot valve exhaust port

(M3: Port PE)Silencer

(AN15-C08)

End plate

(P44027A)

Manual override

Manual override

≅300

(Lead wire length)

Vacuum port

ø6 One-touch fitting Port V ( (

Air pressure supply port

( (ø6 One-touch fitting Port P1

ZYY3LZ-S1(Specifications without vacuum switch)

Circuit diagram

Ejector Valve Dimensions

ZYY3LZ-1-EC

Ejector Valve Unit Series ZYY/ZYX

1065

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 12: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

P

Vacuum switch(With analog output)

P

Vacuum switch(Without analog output)

Silencer

Supply/Release valve

V

P1

Release flow rate adjusting needle

Ejector unit

B

A

15.8

8

25

28.1

28.5

45

20

ø13

Vacuum switch

Hysteresis setting trimmer

Pressure setting trimmer

Accessory (packed together)1. Silencer (AN15-C08···1 pc.)

2. Mounting bolt nut (M2 x 0.4 x 20···4 pcs.)

Circuit diagram

Ejector Valve Dimensions

ZYY3LZ-1-EC-MN

Series ZYY/ZYX

1066

Page 13: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

P

P

BA

BA

P

Vacuum switch(With analog output)

P

Vacuum switch(Without analog output)

Silencer

Supply/Release valve

V

P1

Release flow rate adjusting needle

Ejector unit

333.7

135

35.510.8

1.4

(8.25) (13.5)

49.4

41.6

33.6

88 19

57

33.3

23.5

27

18.8

16.8

(5.25)

62

29.5

21

10

End plate(P44027A)

10.8

Release flow rateadjusting needle

ø6 One-touch fittingPort V

Vacuum port

ø6 One-touch fittingPort P1

Air pressure supply port

(With indicator light and surge voltage suppressor)

Button for block separation

Pressure setting trimmer

Hysteresis setting trimmer

(AN15-C08)Silencer

(M3: Port PE)Pilot valve exhaust port

Vacuum switch

Approx. 600

Indicator light (Red)

Manual overrideA side: Orange (for supply valve)B side: Green (for release valve)

Manual overrideA side: Orange (for supply valve)B side: Green (for release valve)

ZYX3LOZ-1-EC

ZYX3LOZ-S1(Specifications without vacuum switch)

Circuit diagram

Ejector Valve Dimensions

Ejector Valve Unit Series ZYY/ZYX

1067

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 14: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

P

(With analog output)Vacuum switch

(Without analog output)

P

Vacuum switch

Silencer

Supply/Release valve

V

P1

Release flow rate adjusting needle

Ejector unit

ZYX3L-S-EC-F

Circuit diagram

(4)

(300

)

8

35

108.8

(19)27

67

6.73.8

- -+

V

Button for block separation

Ejector Valve Dimensions

Series ZYY/ZYX

1068

Page 15: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

P

P

Vacuum switch(With analog output)

P

Vacuum switch(Without analog output)

Silencer

Supply/Release valve

V

P1

Release flow rate adjusting needle

Ejector unit

- -+

109

859.6

13

28.5

23.5

45

20

ø13

Accessory (packed together)

2. Mounting bolt nut (M2 x 0.4 x 25···4 pcs.)

1. Silencer (AN15-C08···1 pc)

Circuit diagram

Ejector Valve Dimensions

ZYX3L-S1-EC-FMN

Ejector Valve Unit Series ZYY/ZYX

1069

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 16: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

P

P

Vacuum switch(With analog output)

P

Vacuum switch(Without analog output)

Silencer

Supply/Release valve

V

P1

Release flow rate adjusting needle

Ejector unit

B

A

857.4

6.8

45

20

ø13

23.5

28.1

28.5

Accessory (packed together)

2. Mounting bolt nut (M2 x 0.4 x 25···4 pcs.)

1. Silencer (AN15-C08···1 pc)

Circuit diagram

Ejector Valve Dimensions

ZYX3L-S1-EC-MN

Series ZYY/ZYX

1070

Page 17: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

ZYY3000-NPA (Non plug-in assembly)

86

33.6

27

33.3

33.6

106

27

33.3

Ejector Valve Dimensions

ZYY3000-PA (Plug-in assembly)

Ejector Valve Unit Series ZYY/ZYX

1071

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 18: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

L4

5.25

16.516.5

10.5

27 16.5

8 5.5

The length of the standard accessory DIN rail is calculated with the formula below.

C1 Value SelectionSeparate wiring type

Connector box type

D-sub connector 25 pin type

Flat cable type

Terminal block 9 pole type

Terminal block 18 pole type

33

86

(mm)

54

75

81.8

94.3

132

126

Serial transmission type

Indication exampleIn the case of ZZYY3-45-04D-C6∗SY3140-5LZ∗SY3240-5LZ∗SY3340-5LZ∗ZYY35LZ-10S-E15Cthe dimensions areL1 = 135.5 mmL2 = 125 mmL3 = 108 mmL4 = 13.75 mm

Manifold overall length (L3) = (27 x Number of ejector valve stations) + (10.5 x Number of solenoid valve stations) + (16.5 x Number of supply/exhaust block stations) + C1 [mm]Note) In the case of ejector valves only (without solenoid valves), calculate the number of solenoid valve stations and supply/exhaust block stations as “0”.Number of mounting holes (N) = (L3/12.5 + 1): Decimal fractions are truncatedDIN rail overall length (L1) = N x 12.5 + 23 [mm]Mounting screw length (L2) = L1 – 10.5 [mm]Rail length on one side (L4) = (L1 – L3)/2 [mm]

Stations

U side D side

45

45-

45F

45P

45T

45T1

45S

45S1

45S2

45S3

ANA

r ewq

Series ZYY/ZYX

Dimensions of DIN Rail Mounting Unit for ZYY3000/ZYX3000 Manifold

Ejector valve

End plate assembly L End plate assembly R

L1 : Rail overall length

L2 : Mounting screw length

L3 : Manifold overall length

DIN rail

Solenoid valve

Supply/Exhaust block

1072

Page 19: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

1073

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 20: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

q Manifold Model

Please copy this form and use it. (Do not detach this page.)

Fill in the blanks in the order from q to r.

Fill in the blanks below with the symbols for required specifications.

Manifold Valve Specification SheetZYY3000 Individual Wiring Type

w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.

CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery

Date: / / (YY/MM/DD)

(Up to a total of 20 stations)Ejector/Valve stationslayout (Special specifications)

DIN rail manifold

ZZYY3

SpecificationsStandard/Internal pilot specificationExternal pilot specification

∗ : Made to Order

SymbolNilR

Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS

∗∗∗

SUP/EXH block assemblymounting position

45Mounting position

U sideD side

SymbolUD

Ejector mounting position

Number of ejector stations1 to 10 stations

J

U sideMounting position Applicable stations

2 to 10 stations

2 to 20 stationsBoth sides

UD sideD

Symbol

BSpecial specificationsM

A, B port size (valve only)Specifications

One-touch fitting for ø4One-touch fitting for ø6

SymbolC4C6

Mixed sizeM

…2 stations

20 stations

…02StationsSymbol

20

Total number of ejector andvalve stations

A B C D

ZYY3E F G H I J K

Nil Non-locking push typePush-locking slotted type

DManual override

DPush-locking lever typeE

Nil Without light/surge voltage suppressorWith surge voltagesuppressor

CLight/Surge voltage suppressor

S

With light/surge voltage suppressorWith surge voltage suppressor(Non-polar type)With light/surge voltage suppressor(Non-polar type)

Z

R

U

14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting

IOutput specifications (Vacuum switch)

15

NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting

16

17

18

19

55

07 ø0.7 mmø1.0 mm

ENozzle diameter

10

G Grommet (Lead wire length 300 mm)Grommet (Lead wire length 600 mm)

BElectrical entry

HWith lead wires

L plugconnector

M plugconnector

LWithout lead wiresLNWithout connectorLOWith lead wiresMWithout lead wiresMNWithout connectorMO

5 24 VDC12 VDC

DCARated voltage

66 VDCV5 VDCS3 VDCR

1 100 VAC200 VAC

AC (50/60 HZ)

2110 VAC (115 V)3220 VAC (230 V)4

S –84 kPa–53 kPa

FMax. vacuum pressure

L

Nil NoneWith silencer

GSilencer

1

Nil NoneWith vacuum switch

HVacuum switch

E

NilNoneWith manifold block

KManifold block

MN

Nil

JWiring specifications (Vacuum switch)

LLead wire length 0.6 mGrommet

type

Connectortype

Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

CCLCN

U side D side

n

m t

r

r

e

e w

w

q

q

Note) • U, R: 24 VDC only.• Since surge voltage is prevent-

ed with a rectifier in the case of AC, there is no type “S”.

The number of blanking plate assembly is included.

For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.

SUP/EXH block assemblyspecifications

For special specifications, specify using the Stations Table on the next page.

1074

Page 21: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

e Valve ModelFill in the blanks below with the symbols for required specifications.

For SMC Use Only

r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc.

Model No. Qty. Model No. Qty. Customer code

Code for person in charge

Departmental code

SY3 40

NilR External pilot

Internal pilot

Pilot method

2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center

Specify using the Stations Table below.

12345

Type of actuation

DA B C

Nil Non-locking push typePush-locking slotted type

DManual override

DPush-locking lever typeE

Nil Without light/surge voltage suppressorWith surge voltagesuppressor

CLight/Surge voltage suppressor

S

With light/surge voltage suppressorWith surge voltage suppressor(Non-polar type)With light/surge voltage suppressor(Non-polar type)

Z

R

U

GGrommet (Lead wire length 600 mm)Grommet (Lead wire length 300 mm)

BElectrical entry

H

L plugconnector

M plugconnector

LLNLOM

MN

With lead wiresWithout lead wiresWithout connectorWith lead wiresWithout lead wiresWithout connectorMO

5

DCARated voltage

6VS

24 VDC12 VDC6 VDC5 VDC3 VDCR

1

AC (50/60HZ)

23

100 VAC200 VAC110 VAC (115 V)220 VAC (230 V)4

Valve stations or Layout

Eje

ctor

spe

cific

atio

nsV

alve

spe

cific

atio

ns

Noz

zle

diam

eter

07

Noz

zle

diam

eter

10

Acces

sory

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Withsilencer

Withoutsilencer

Withsilencer

Withoutsilencer

Withsilencer

WithoutsilencerWithsilencer

Withoutsilencer

With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch

Single solenoidDouble solenoidCosed centerExhaust centerPressure center

SUP/EXH block assembly

Non-plug assembly

Blanking plate assembly

SUP blocking diskEXH blocking disk

A, B port size (Mixed specifications)

Individual SUP spacer assemblyIndividual EXH spacer assembly

2 position

3 position

Fill in to orderspecial specifications.

Quantity1234567891011121314151617181920

• Individual SUP spacer assembly: SY3000-38-2A• Individual EXH spacer assembly: SY3000-39-2A• SUP/EXH block assembly (Standard): SX3000-51-1A

• SUP/EXH block assembly (R): SX3000-51-3A• SUP/EXH block assembly (S): SX3000-51-4A • SUP/EXH block assembly (RS): SX3000-51-5A

Note) • Non-plug assembly: ZYY3000-NPA• Blanking plate assembly: SX3000-75-1A• SUP blocking disk: SX3000-77-1A• EXH blocking disk: SX3000-77-1A

Two pieces usedfor one station

Note) • U, R: 24 VDC only.• Since surge voltage is prevent-

ed with a rectifier in the case of AC, there is no type “S”.

Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.

∗ ∗

Put "" in the blanks of "External pilot specification" in the Stations Table below to use external pilot valves.

1075

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 22: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

q Manifold ModelFill in the blanks below with the symbols for required specifications.

w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.

(Up to a total of 20 stations)Ejector/Valve stationslayout (Special specifications)

ZZYX3 45 J

A B C D

ZYX3E F G H I J K L

Nil Non-locking push typePush-locking slotted type

DManual override

D

Nil Without light/surge voltage suppressorWith surge voltagesuppressor

CLight/Surge voltage suppressor

S

With light/surge voltage suppressorZ

BElectrical entry

ARated voltageDC

NilNon plug-in typePlug-in type

KManifold type

F

LManifold block

U side D side

n

m t

r

r

e

e w

w

q

q

Fill in the blanks in the order from q to r.

Please copy this form and use it. (Do not detach this page.)

Manifold Valve Specification SheetZYX3000 Individual Wiring Type Company

Person in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery

Date: / / (YY/MM/DD)

DIN rail manifold

SpecificationsStandard/Internal pilot specificationExternal pilot specification

∗ : Made to Order

SymbolNilR

Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS

∗ ∗ ∗

SUP/EXH block assemblyspecifications

SUP/EXH block assemblymounting position

Mounting positionU sideD side

SymbolUD

Ejector mounting position

Number of ejector stations1 to 10 stationsU side

Mounting position Applicable stations

2 to 10 stations

2 to 20 stationsBoth sides

UD sideD

Symbol

BSpecial specificationsM

A, B port size (valve only)Specifications

One-touch fitting for ø4One-touch fitting for ø6

SymbolC4C6

Mixed sizeM

…2 stations

20 stations

…02StationsSymbol

20

14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting

IOutput specifications (Vacuum switch)

15

NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting

16

17

18

19

55

07 ø0.7 mmø1.0 mm

ENozzle diameter

10

G Grommet (Lead wire length 300 mm)Grommet (Lead wire length 600 mm)H

With lead wiresL plugconnector

M plugconnector

LWithout lead wiresLNWithout connectorLOWith lead wiresMWithout lead wiresMNWithout connectorMO

5 24 VDC12 VDC66 VDCV5 VDCS3 VDCR

S –84 kPa–53 kPa

FMax. vacuum pressure

L

Nil NoneWith silencer

GSilencer

1

Nil NoneWith vacuum switch

HVacuum switch

E

NilNoneWith manifold block

MN

Nil

JWiring specifications (Vacuum switch)

LLead wire length 0.6 mGrommet

type

Connectortype

Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

CCLCN

The number of blanking plate assembly is included. For special specifications, specify

using the Stations Table on the next page.

For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.

Total number of ejector andvalve stations

1076

Page 23: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

e Valve ModelFill in the blanks below with the symbols for required specifications.

SX3 40R

DA B CNil Without light/

surge voltage suppressorWith surge voltagesuppressor

CLight/Surge voltage suppressor

S

With light/surge voltage suppressorZ

BElectrical entryARated voltage2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center

12345

Type of actuation

Nil Non-locking push typePush-locking slotted type

DManual override

D

GGrommet (Lead wire length 600 mm)Grommet (Lead wire length 300 mm)

H

L plugconnector

M plugconnector

LLNLOM

MN

With lead wiresWithout lead wiresWithout connectorWith lead wiresWithout lead wiresWithout connectorMO

56VS

24 VDC12 VDC6 VDC5 VDC3 VDCR

Valve stations or Layout

Eje

ctor

spe

cific

atio

nsV

alve

spe

cific

atio

ns

Noz

zle

diam

eter

07

Noz

zle

diam

eter

10

Acces

sory

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Withsilencer

Withoutsilencer

Withsilencer

Withoutsilencer

Withsilencer

WithoutsilencerWithsilencer

Withoutsilencer

With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch

Single solenoidDouble solenoidCosed centerExhaust centerPressure center

Non-plug assembly

Blanking plate assembly

SUP blocking diskEXH blocking disk

A, B port size (Mixed specifications)

Individual SUP spacer assemblyIndividual EXH spacer assembly

2 position

3 position

Quantity1234567891011121314151617181920

• Individual SUP spacer assembly: SY3000-38-2A

• Individual EXH spacer assembly: SY3000-39-2A

• SUP/EXH block assembly (Standard): SX3000-51-1A

• SUP/EXH block assembly (R): SX3000-51-3A

• SUP/EXH block assembly (S): SX3000-51-4A

• SUP/EXH block assembly (RS): SX3000-51-5A

Note) • Non-plug assembly: ZYY3000-NPA

• Blanking plate assembly: SX3000-75-1A

• SUP blocking disk: SX3000-77-1A

• EXH blocking disk: SX3000-77-1A

∗SX3∗40: Internal pilotSX3∗40R: External pilot

Specify using the Stations Table below.

r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)

SUP/EXH block assemblyFill in to orderspecial specifications.

Two pieces usedfor one station

For SMC Use Only

Model No. Qty. Model No. Qty. Customer code

Code for person in charge

Departmental code

Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.

a

1077

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 24: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

q Manifold Model

Please copy this form and use it. (Do not detach this page.)

Fill in the blanks below with the symbols for required specifications.

Manifold Valve Specification SheetFill in the blanks in the order from q to r.

ZYX3000 Terminal Block (9 Pins)

w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.

(Up to a total of 7 stations)Ejector/Valve stationslayout (Special specifications)

DIN rail manifold

ZZYX3 45T Ejector mounting position

Number of ejector stations1 to 3 stations

J

Mounting positionU sideD side

SymbolUD

Connector mountingposition

Total number of ejector and valve stations

2 stationsStations Note

The number of blanking plate assembly is included.

Double wiring specification4 stations

02Symbol

045 stations

7 stations

05

07

SUP/EXH block assemblymounting position

U sideMounting position

Both sides

UD sideD

Symbol

BSpecial specificationsM

A B C D

ZYX3 LOZE F G H I J

CManual override

HOutput specifications (Vacuum switch)DNozzle diameter

5 24 VDC12 VDC

ARated voltage

6

Nil Positive commonNegative common

BCommon specifications

N

EMax. vacuum pressure

FSilencer

GVacuum switch

JManifold block

IWiring specifications (Vacuum switch)

U side D side

n

m t

r

r

e

e w

w

q

q

CO

M1

23

46

78

5

CO

M8

76

54

32

1

Connector blockNote) Connector block is not included in the stations and layout.

SpecificationsStandard/Internal pilot specificationExternal pilot specification

∗ : Made to Order

SymbolNilR

Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS

∗ ∗ ∗

SUP/EXH block assembly specifications

Mounting positionU sideD side

SymbolUD

……

……

Nil Non-locking push typePush-locking slotted typeD

CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery

Date: / / (YY/MM/DD)

14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15

NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting

16

17

18

19

55

07 ø0.7 mmø1.0 mm10

S –84 kPa–53 kPaL

Nil NoneWith silencer1

Nil NoneWith vacuum switchE

NilNoneWith manifold block

MN

NilL

Lead wire length 0.6 mGrommettype

Connectortype

Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

CCLCN

Match with the common specification of the manifold.

Match with the voltage specification of the manifold.

A, B port size (valve only)Specifications

One-touch fitting for ø4One-touch fitting for ø6

SymbolC4C6

Mixed sizeMFor ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.

Up to 8 solenoids possible. Specify wiring specifications using the Stations Table. For special specifications, specify

using the Stations Table on the next page.

1078

Page 25: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

Quantity1234567

e Valve ModelFill in the blanks below with the symbols for required specifications.

SX3 LOZ40R

A B C

CManual override

5 24 VDC12 VDC

ARated voltage

6Nil Positive common

Negative common

BCommon specifications

N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center

12345

Type of actuation

• Individual SUP spacer assembly: SX3000-38-3A

• Individual EXH spacer assembly: SX3000-39-3A

• SUP/EXH block assembly (Standard): SX3000-51-2A

• SUP/EXH block assembly (R): SX3000-51-6A

• SUP/EXH block assembly (S): SX3000-51-7A

• SUP/EXH block assembly (RS): SX3000-51-8A

Note) • Plug-in assembly: ZYY3000-PA

• Blanking plate assembly: SX3000-75-2A

• SUP blocking disk: SX3000-77-1A

• EXH blocking disk: SX3000-77-1A

Wiringspecifications

Single wiringDouble wiring

Fill in only when the stations are more than five or specifying wiring specifications for four stations or less is required.

Valve stations or Layout

Eje

ctor

spe

cific

atio

nsV

alve

spe

cific

atio

ns

Noz

zle

diam

eter

07

Noz

zle

diam

eter

10

Acces

sory

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Withsilencer

Withoutsilencer

Withsilencer

Withoutsilencer

Withsilencer

WithoutsilencerWithsilencer

Withoutsilencer

With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch

Single solenoidDouble solenoidCosed centerExhaust centerPressure center

Plug-in assembly

Blanking plate assembly

SUP blocking diskEXH blocking disk

A, B port size (Mixed specifications)

Individual SUP spacer assemblyIndividual EXH spacer assembly

2 position

3 position

Nil Non-locking push typePush-locking slotted typeD

Match with the voltage specification of the manifold.

Match with the common specification of the manifold.

∗SX3∗40: Internal pilotSX3∗40R: External pilot

Specify using the Stations Table below.

r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)

SUP/EXH block assemblyFill in to orderspecial specifications.

Two pieces usedfor one station

For SMC Use Only

Model No. Qty. Model No. Qty. Customer code

Code for person in charge

Departmental code

Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.

a

1079

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 26: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.

(Up to a total of 16 stations)Ejector/Valve stationslayout (Special specifications)

ZZYX3 45T1 Ejector mountingposition

Number of ejector stations1 to 8 stations

J

Total number of ejector and valve stations

A B C D

ZYX3 LOZE F G H I J

U side D side

n

m t

r

r

e

e w

w

q

q

Connector blockNote) Connector block is not included in the stations and layout.

q Manifold Model

Please copy this form and use it. (Do not detach this page.)

Fill in the blanks below with the symbols for required specifications.

Manifold Valve Specification SheetFill in the blanks in the order from q to r.

ZYX3000 Terminal Block (18 Pins)DIN rail manifold

Mounting positionU sideD side

SymbolUD

Mounting positionU sideD side

SymbolUD

Connector mountingposition

2 stationsStations Note

The number of blanking plate assembly is included.

Double wiring specification8 stations

02Symbol

089 stations

16 stations

09

16

CManual override

HOutput specifications (Vacuum switch)DNozzle diameter

5 24 VDC12 VDC

ARated voltage

6

Nil Positive commonNegative common

BCommon specifications

N

EMax. vacuum pressure

FSilencer

GVacuum switch

JManifold block

IWiring specifications (Vacuum switch)

SpecificationsStandard/Internal pilot specificationExternal pilot specification

∗ : Made to Order

SymbolNilR

Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS

∗ ∗ ∗

SUP/EXH block assembly specifications

……

……

Nil Non-locking push typePush-locking slotted typeD

CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery

Date: / / (YY/MM/DD)

14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15

NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting

16

17

18

19

55

07 ø0.7 mmø1.0 mm10

S –84 kPa–53 kPaL

Nil NoneWith silencer1

Nil NoneWith vacuum switchE

NilNoneWith manifold block

MN

NilL

Lead wire length 0.6 mGrommettype

Connectortype

Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

CCLCN

Match with the common specification of the manifold.

Match with the voltage specification of the manifold.

A, B port size (valve only)Specifications

One-touch fitting for ø4One-touch fitting for ø6

SymbolC4C6

Mixed sizeMFor ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.

Up to 17 solenoids possible. Specify wiring specifications using the Stations Table.

SUP/EXH block assemblymounting position

U sideMounting position Valve applicable stations

2 to 10 stations

2 to 16 stationsBoth sides

UD sideD

Symbol

BSpecial specificationsM

For special specifications, specify using the Stations Table on the next page.

1080

Page 27: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

e Valve ModelFill in the blanks below with the symbols for required specifications.

r

SX3 LOZ40R

A B C

• Individual SUP spacer assembly: SX3000-38-3A

• Individual EXH spacer assembly: SX3000-39-3A

• SUP/EXH block assembly (Standard): SX3000-51-2A

• SUP/EXH block assembly (R): SX3000-51-6A

• SUP/EXH block assembly (S): SX3000-51-7A

• SUP/EXH block assembly (RS): SX3000-51-8A

Note) • Plug-in assembly: ZYY3000-PA

• Blanking plate assembly: SX3000-75-2A

• SUP blocking disk: SX3000-77-1A

• EXH blocking disk: SX3000-77-1A

Fill in only when the stations are more than nine or specifying wiring specifications for eight stations or less is required.

Valve stations or Layout

Eje

ctor

spe

cific

atio

nsV

alve

spe

cific

atio

ns

Noz

zle

diam

eter

07

Noz

zle

diam

eter

10

Acces

sory

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Withsilencer

Withoutsilencer

Withsilencer

Withoutsilencer

Withsilencer

WithoutsilencerWithsilencer

Withoutsilencer

With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch

Single solenoidDouble solenoidCosed centerExhaust centerPressure center

Plug-in assembly

Blanking plate assembly

SUP blocking diskEXH blocking disk

A, B port size (Mixed specifications)

Individual SUP spacer assemblyIndividual EXH spacer assembly

2 position

3 position

Quantity12345678910111213141516

CManual override

5 24 VDC12 VDC

ARated voltage

6Nil Positive common

Negative common

BCommon specifications

N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center

12345

Type of actuation

Nil Non-locking push typePush-locking slotted typeD

Match with the voltage specification of the manifold.

Match with the common specification of the manifold.

∗SX3∗40: Internal pilotSX3∗40R: External pilot

Specify using the Stations Table below.

r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)

SUP/EXH block assemblyFill in to orderspecial specifications.

Two pieces usedfor one station

For SMC Use Only

Model No. Qty. Model No. Qty. Customer code

Code for person in charge

Departmental code

Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.

a

Wiringspecifications

Single wiringDouble wiring

1081

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 28: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

Fill in the blanks below with the symbols for required specifications.

w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.

(Up to a total of 7 stations)Ejector/Valve stationslayout (Special specifications)

ZZYX3 45 PH

Number of ejector stations1 to 3 stations

J

Positive commonNegative common

NilN

Common specifications

24 VDC12 VDC

Nil12V

Voltage

A B C D

ZYX3 LOZE F G H I J

U side D side

n

m t

r

r

e

e w

w

q

q

Connector blockNote) Connector block is not included in the stations and layout.

24VDC+COM

q Manifold Model

Please copy this form and use it. (Do not detach this page.)

Manifold Valve Specification SheetFill in the blanks in the order from q to r.

ZYX3000 Flat Ribbon Cable 10 PinsDIN rail manifold

Mounting positionU sideD side

SymbolUD

Connector mountingposition

SUP/EXH block assemblymounting position

U sideMounting position

Both sides

UD sideD

Symbol

BSpecial specificationsM

CManual override

HOutput specifications (Vacuum switch)DNozzle diameter

5 24 VDC12 VDC

ARated voltage

6

Nil Positive commonNegative common

BCommon specifications

N

EMax. vacuum pressure

FSilencer

GVacuum switch

JManifold block

IWiring specifications (Vacuum switch)

SpecificationsStandard/Internal pilot specificationExternal pilot specification

∗ : Made to Order

SymbolNilR

Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS

∗ ∗ ∗

SUP/EXH block assembly specifications

Nil Non-locking push typePush-locking slotted typeD

CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery

Date: / / (YY/MM/DD)

14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15

NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting

16

17

18

19

55

07 ø0.7 mmø1.0 mm10

S –84 kPa–53 kPaL

Nil NoneWith silencer1

Nil NoneWith vacuum switchE

NilNoneWith manifold block

MN

NilL

Lead wire length 0.6 mGrommettype

Connectortype

Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

CCLCN

Match with the common specification of the manifold.

Match with the voltage specification of the manifold.

A, B port size (valve only)Specifications

One-touch fitting for ø4One-touch fitting for ø6

SymbolC4C6

Mixed sizeM

Total number of ejector and valve stations

2 stationsStations Note

The number of blanking plate assembly is included.

Double wiring specification4 stations

02Symbol

045 stations

7 stations

05

07

……

…… Up to 8 solenoids possible.

Specify wiring specifications using the Stations Table.

Ejector mountingposition

Mounting positionU sideD side

SymbolUD

For special specifications, specify using the Stations Table on the next page.

For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.

1082

Page 29: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

e Valve ModelFill in the blanks below with the symbols for required specifications.

SX3 LOZ40R

A B C

• Individual SUP spacer assembly: SX3000-38-3A

• Individual EXH spacer assembly: SX3000-39-3A

• SUP/EXH block assembly (Standard): SX3000-51-2A

• SUP/EXH block assembly (R): SX3000-51-6A

• SUP/EXH block assembly (S): SX3000-51-7A

• SUP/EXH block assembly (RS): SX3000-51-8A

Note) • Plug-in assembly: ZYY3000-PA

• Blanking plate assembly: SX3000-75-2A

• SUP blocking disk: SX3000-77-1A

• EXH blocking disk: SX3000-77-1A

Quantity1234567

Fill in only when the stations are more than five or specifying wiring specifications for four stations or less is required.

Valve stations or Layout

Eje

ctor

spe

cific

atio

nsV

alve

spe

cific

atio

ns

Noz

zle

diam

eter

07

Noz

zle

diam

eter

10

Acces

sory

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Withsilencer

Withoutsilencer

Withsilencer

Withoutsilencer

Withsilencer

WithoutsilencerWithsilencer

Withoutsilencer

With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch

Single solenoidDouble solenoidCosed centerExhaust centerPressure center

Plug-in assembly

SUP blocking diskEXH blocking disk

A, B port size (Mixed specifications)

Individual SUP spacer assemblyIndividual EXH spacer assembly

2 position

3 position

CManual override

5 24 VDC12 VDC

ARated voltage

6Nil Positive common

Negative common

BCommon specifications

N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center

12345

Type of actuation

Nil Non-locking push typePush-locking slotted typeD

Match with the voltage specification of the manifold.

Match with the common specification of the manifold.

∗SX3∗40: Internal pilotSX3∗40R: External pilot

Specify using the Stations Table below.

r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)

Blanking plate assemblySUP/EXH block assemblyFill in to order

special specifications.

Two pieces usedfor one station

For SMC Use Only

Model No. Qty. Model No. Qty. Customer code

Code for person in charge

Departmental code

Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.

a

Wiringspecifications

Single wiringDouble wiring

1083

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 30: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.

(Up to a total of 15 stations)Ejector/Valve stationslayout (Special specifications)

ZZYX3 45 PG

Number of ejector stations1 to 7 stations

J

Total number of ejector and valve stations

A B C D

ZYX3 LOZE F G H I J

U side D side

n

m t

r

r

e

e w

w

q

q

Connector blockNote) Connector block is not included in the stations and layout.

24VDC+COM

CManual override

HOutput specifications (Vacuum switch)DNozzle diameter

5 24 VDC12 VDC

ARated voltage

6

Nil Positive commonNegative common

BCommon specifications

N

EMax. vacuum pressure

FSilencer

GVacuum switch

JManifold block

IWiring specifications (Vacuum switch)

Nil Non-locking push typePush-locking slotted typeD

14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15

NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting

16

17

18

19

55

07 ø0.7 mmø1.0 mm10

S –84 kPa–53 kPaL

Nil NoneWith silencer1

Nil NoneWith vacuum switchE

NilNoneWith manifold block

MN

NilL

Lead wire length 0.6 mGrommettype

Connectortype

Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

CCLCN

Match with the common specification of the manifold.

Match with the voltage specification of the manifold.

Fill in the blanks below with the symbols for required specifications.

q Manifold Model

Please copy this form and use it. (Do not detach this page.)

Manifold Valve Specification SheetFill in the blanks in the order from q to r.

ZYX3000 Flat Ribbon Cable 20 PinsDIN rail manifold

CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery

Date: / / (YY/MM/DD)

Positive commonNegative common

NilN

Common specifications

24 VDC12 VDC

Nil12V

Voltage

Mounting positionU sideD side

SymbolUD

Connector mountingposition

SpecificationsStandard/Internal pilot specificationExternal pilot specification

∗ : Made to Order

SymbolNilR

Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS

∗ ∗ ∗

SUP/EXH block assembly specifications

A, B port size (valve only)Specifications

One-touch fitting for ø4One-touch fitting for ø6

SymbolC4C6

Mixed sizeM

2 stationsStations Note

The number of blanking plate assembly is included.

Double wiring specification8 stations

02Symbol

089 stations

15 stations

09

15

……

…… Up to 16 solenoids possible.

Specify wiring specifications using the Stations Table.

Ejector mountingposition

Mounting positionU sideD side

SymbolUD

SUP/EXH block assemblymounting position

U sideMounting position Valve applicable stations

2 to 10 stations

2 to 15 stationsBoth sides

UD sideD

Symbol

BSpecial specificationsM

For special specifications, specify using the Stations Table on the next page.

For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.

1084

Page 31: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

e Valve ModelFill in the blanks below with the symbols for required specifications.

SX3 LOZ40R∗A B C

SX3∗40: Internal pilotSX3∗40R: External pilot

• Individual SUP spacer assembly: SX3000-38-3A

• Individual EXH spacer assembly: SX3000-39-3A

• SUP/EXH block assembly (Standard): SX3000-51-2A

• SUP/EXH block assembly (R): SX3000-51-6A

• SUP/EXH block assembly (S): SX3000-51-7A

• SUP/EXH block assembly (RS): SX3000-51-8A

Note) • Plug-in assembly: ZYY3000-PA

• Blanking plate assembly: SX3000-75-2A

• SUP blocking disk: SX3000-77-1A

• EXH blocking disk: SX3000-77-1A

Fill in only when the stations are more than nine or specifying wiring specifications for eight stations or less is required.

Valve stations or Layout

Eje

ctor

spe

cific

atio

nsV

alve

spe

cific

atio

ns

Noz

zle

diam

eter

07

Noz

zle

diam

eter

10

Acces

sory

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Withsilencer

Withoutsilencer

Withsilencer

Withoutsilencer

Withsilencer

WithoutsilencerWithsilencer

Withoutsilencer

With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch

Single solenoidDouble solenoidCosed centerExhaust centerPressure center

SUP blocking diskEXH blocking disk

A, B port size (Mixed specifications)

Individual SUP spacer assemblyIndividual EXH spacer assembly

2 position

3 position

Quantity123456789101112131415

CManual override

5 24 VDC12 VDC

Rated voltage

6Nil Positive common

Negative common

Common specifications

N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center

12345

Type of actuation

Nil Non-locking push typePush-locking slotted typeD

Match with the voltage specification of the manifold.

Match with the common specification of the manifold.

Specify using the Specifications Table below.

r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)

Blanking plate assemblySUP/EXH block assemblyFill in to order

special specifications.

Two pieces usedfor one station

For SMC Use Only

Model No. Qty. Model No. Qty. Customer code

Code for person in charge

Departmental code

Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.

a

A B

Wiringspecifications

Single wiringDouble wiring

Plug-in assembly

1085

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 32: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

n

m t

r

r

e

e w

w

q

q

Connector blockNote) Connector block is not included in the stations and layout.

q Manifold ModelFill in the blanks below with the symbols for required specifications.

w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.

(Up to a total of 19 stations)Ejector/Valve stationslayout (Special specifications)

ZZYX3 45 P

Number of ejector stations1 to 10 stations

J

Total number of ejector and valve stations

A B C D

ZYX3 LOZE F G H I J

U side D side

Fill in the blanks in the order from q to r.

CManual override

HOutput specifications (Vacuum switch)DNozzle diameter

5 24 VDC12 VDC

ARated voltage

6

Nil Positive commonNegative common

BCommon specifications

N

EMax. vacuum pressure

FSilencer

GVacuum switch

JManifold block

IWiring specifications (Vacuum switch)

Nil Non-locking push typePush-locking slotted typeD

14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15

NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting

16

17

18

19

55

07 ø0.7 mmø1.0 mm10

S –84 kPa–53 kPaL

Nil NoneWith silencer1

Nil NoneWith vacuum switchE

NilNoneWith manifold block

MN

NilL

Lead wire length 0.6 mGrommettype

Connectortype

Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

CCLCN

Match with the common specification of the manifold.

Match with the voltage specification of the manifold.

Please copy this form and use it. (Do not detach this page.)

Manifold Valve Specification SheetZYX3000 Flat Ribbon Cable 26 PinsDIN rail manifold

CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery

Date: / / (YY/MM/DD)

Positive commonNegative common

NilN

Common specifications

24 VDC12 VDC

Nil12V

Voltage

Mounting positionU sideD side

SymbolUD

Connector mountingposition

SpecificationsStandard/Internal pilot specificationExternal pilot specification

∗ : Made to Order

SymbolNilR

Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS

∗ ∗ ∗

SUP/EXH block assembly specifications

A, B port size (valve only)Specifications

One-touch fitting for ø4One-touch fitting for ø6

SymbolC4C6

Mixed sizeM

2 stationsStations Note

The number of blanking plate assembly is included.

Double wiring specification10 stations

02Symbol

1011 stations

19 stations

11

19

……

…… Up to 20 solenoids possible.

Specify wiring specifications using the Stations Table.

Ejector mountingposition

Mounting positionU sideD side

SymbolUD

SUP/EXH block assemblymounting position

U sideMounting position Valve applicable stations

2 to 10 stations

2 to 19 stationsBoth sides

UD sideD

Symbol

BSpecial specificationsM

For special specifications, specify using the Stations Table on the next page.

For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.

1086

Page 33: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

• Individual SUP spacer assembly: SX3000-38-3A

• Individual EXH spacer assembly: SX3000-39-3A

• SUP/EXH block assembly (Standard): SX3000-51-2A

• SUP/EXH block assembly (R): SX3000-51-6A

• SUP/EXH block assembly (S): SX3000-51-7A

• SUP/EXH block assembly (RS): SX3000-51-8A

Note) • Plug-in assembly: ZYY3000-PA

• Blanking plate assembly: SX3000-75-2A

• SUP blocking disk: SX3000-77-1A

• EXH blocking disk: SX3000-77-1A

Fill in only when the stations are more than eleven or specifying wiring specifications for ten stations or less is required.

Valve stations or Layout

Eje

ctor

spe

cific

atio

nsV

alve

spe

cific

atio

ns

Noz

zle

diam

eter

07

Noz

zle

diam

eter

10

Acces

sory

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Withsilencer

Withoutsilencer

Withsilencer

Withoutsilencer

Withsilencer

WithoutsilencerWithsilencer

Withoutsilencer

With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch

Single solenoidDouble solenoidCosed centerExhaust centerPressure center

Plug-in assembly

SUP blocking diskEXH blocking disk

A, B port size (Mixed specifications)

Individual SUP spacer assemblyIndividual EXH spacer assembly

2 position

3 position

Quantity12345678910111213141516171819

SX3 LOZ40R

A B C

CManual override

5 24 VDC12 VDC

ARated voltage

6Nil Positive common

Negative common

BCommon specifications

N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center

12345

Type of actuation

Nil Non-locking push typePush-locking slotted typeD

Match with the voltage specification of the manifold.

Match with the common specification of the manifold.

∗e Valve Model

Fill in the blanks below with the symbols for required specifications. SX3∗40: Internal pilotSX3∗40R: External pilot

Specify using the Specifications Table below.

r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)

Blanking plate assemblySUP/EXH block assemblyFill in to order

special specifications.

Two pieces usedfor one station

For SMC Use Only

Model No. Qty. Model No. Qty. Customer code

Code for person in charge

Departmental code

Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.

a

Wiringspecifications

Single wiringDouble wiring

1087

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 34: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

q Manifold ModelFill in the blanks below with the symbols for required specifications.

w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.

(Up to a total of 19 stations)Ejector/Valve stationslayout (Special specifications)

ZZYX3 45 F J

A B C D

ZYX3 LOZE F G H I J

U side D side

n

m t

r

r

e

e w

w

q

q

Connector blockNote) Connector block is not included in the stations and layout.

24VDC+COM

Fill in the blanks in the order from q to r.

Number of ejector stations1 to 10 stations

Total number of ejector and valve stations

CManual override

HOutput specifications (Vacuum switch)DNozzle diameter

5 24 VDC12 VDC

ARated voltage

6

Nil Positive commonNegative common

BCommon specifications

N

EMax. vacuum pressure

FSilencer

GVacuum switch

JManifold block

IWiring specifications (Vacuum switch)

Nil Non-locking push typePush-locking slotted typeD

14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15

NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting

16

17

18

19

55

07 ø0.7 mmø1.0 mm10

S –84 kPa–53 kPaL

Nil NoneWith silencer1

Nil NoneWith vacuum switchE

NilNoneWith manifold block

MN

NilL

Lead wire length 0.6 mGrommettype

Connectortype

Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

CCLCN

Match with the common specification of the manifold.

Match with the voltage specification of the manifold.

Please copy this form and use it. (Do not detach this page.)

Manifold Valve Specification SheetZYX3000 D-sub ConnectorDIN rail manifold

CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery

Date: / / (YY/MM/DD)

Positive commonNegative common

NilN

Common specifications

24 VDC12 VDC

Nil12V

Voltage

Mounting positionU sideD side

SymbolUD

Connector mountingposition

SpecificationsStandard/Internal pilot specificationExternal pilot specification

∗ : Made to Order

SymbolNilR

Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS

∗ ∗ ∗

SUP/EXH block assembly specifications

A, B port size (valve only)Specifications

One-touch fitting for ø4One-touch fitting for ø6

SymbolC4C6

Mixed sizeM

2 stationsStations Note

The number of blanking plate assembly is included.

Double wiring specification10 stations

02Symbol

1011 stations

19 stations

11

19

……

…… Up to 20 solenoids possible.

Specify wiring specifications using the Stations Table.

Ejector mountingposition

Mounting positionU sideD side

SymbolUD

SUP/EXH block assemblymounting position

U sideMounting position Valve applicable stations

2 to 10 stations

2 to 19 stationsBoth sides

UD sideD

Symbol

BSpecial specificationsM

For special specifications, specify using the Stations Table on the next page.

For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.

1088

Page 35: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

• Individual SUP spacer assembly: SX3000-38-3A

• Individual EXH spacer assembly: SX3000-39-3A

• SUP/EXH block assembly (Standard): SX3000-51-2A

• SUP/EXH block assembly (R): SX3000-51-6A

• SUP/EXH block assembly (S): SX3000-51-7A

• SUP/EXH block assembly (RS): SX3000-51-8A

Note) • Plug-in assembly: ZYY3000-PA

• Blanking plate assembly: SX3000-75-2A

• SUP blocking disk: SX3000-77-1A

• EXH blocking disk: SX3000-77-1A

Fill in only when the stations are more than eleven or specifying wiring specifications for ten stations or less is required.

Valve stations or Layout

Eje

ctor

spe

cific

atio

nsV

alve

spe

cific

atio

ns

Noz

zle

diam

eter

07

Noz

zle

diam

eter

10

Acces

sory

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Withsilencer

Withoutsilencer

Withsilencer

Withoutsilencer

Withsilencer

WithoutsilencerWithsilencer

Withoutsilencer

With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch

Single solenoidDouble solenoidCosed centerExhaust centerPressure center

Plug-in assembly

SUP blocking diskEXH blocking disk

A, B port size (Mixed specifications)

Individual SUP spacer assemblyIndividual EXH spacer assembly

2 position

3 position

Quantity12345678910111213141516171819

SX3 LOZ40R

A B C

CManual override

5 24 VDC12 VDC

ARated voltage

6Nil Positive common

Negative common

BCommon specifications

N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center

12345

Type of actuation

Nil Non-locking push typePush-locking slotted typeD

Match with the voltage specification of the manifold.

Match with the common specification of the manifold.

∗e Valve Model

Fill in the blanks below with the symbols for required specifications. SX3∗40: Internal pilotSX3∗40R: External pilot

Specify using the Stations Table below.

r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)

Blanking plate assemblySUP/EXH block assemblyFill in to order

special specifications.

Two pieces usedfor one station

For SMC Use Only

Model No. Qty. Model No. Qty. Customer code

Code for person in charge

Departmental code

Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.

a

Wiringspecifications

Single wiringDouble wiring

1089

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 36: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

q Manifold ModelFill in the blanks below with the symbols for required specifications.

w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.

(Up to a total of 15 stations)Ejector/Valve stationslayout (Special specifications)

ZZYX3 45S

Number of ejector stations1 to 7 stations

J

Protocol typeWithout SI unitNKE Corp.: Fieldbus SystemNKE Corp.: Fieldbus H SystemPanasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs)Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs)DeviceNetTM

OMRON Corp.: CompoBus/S (16 outputs) compatibleOMRON Corp.: CompoBus/S (8 outputs) compatibleCC-LINKCompoNetTM

Symbol0

F1HJ1J2QR1R2V

ZB

SI unit specifications

A B C

ZYX3 5 LOZD E F G H J

BManual override

ACommon specifications

Ratedvoltage24 VDC

U side D side

n

m t

r

r

e

e w

w

q

q

Fill in the blanks in the order from q to r.

GOutput specifications (Vacuum switch)CNozzle diameter

Nil Positive commonNegative commonN

DMax. vacuum pressure

ESilencer

FVacuum switch

JManifold block

HWiring specifications (Vacuum switch)

Nil Non-locking push typePush-locking slotted typeD

14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15

NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting

16

17

18

19

55

07 ø0.7 mmø1.0 mm10

S –84 kPa–53 kPaL

Nil NoneWith silencer1

Nil NoneWith vacuum switchE

NilNoneWith manifold block

MN

NilL

Lead wire length 0.6 mGrommettype

Connectortype

Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

CCLCN

Match with the common specification of the manifold.

Please copy this form and use it. (Do not detach this page.)

Manifold Valve Specification SheetZYX3000 Serial Wiring Type (Bar Stock Type)DIN rail manifold

CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery

Date: / / (YY/MM/DD)

SpecificationsStandard/Internal pilot specificationExternal pilot specification

∗ : Made to Order

SymbolNilR

Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS

∗ ∗ ∗

SUP/EXH block assembly specifications

A, B port size (valve only)Specifications

One-touch fitting for ø4One-touch fitting for ø6

SymbolC4C6

Mixed sizeM

2 stationsStations Note

The number of blanking plate assembly is included.

Double wiring specification8 stations

02Symbol

089 stations

15 stations

09

15

……

…… Up to 16 solenoids possible.

Specify wiring specifications using the Stations Table.

Ejector mountingposition

Mounting positionU sideD side

SymbolUD

SUP/EXH block assemblymounting position

U sideMounting position Valve applicable stations

2 to 10 stations

2 to 15 stationsBoth sides

UD sideD

Symbol

BSpecial specificationsM

For special specifications, specify using the Stations Table on the next page.

For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.

Total number of ejector and valve stations

1090

Page 37: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

SX3 LOZ540R

A

AManual overrideRated voltage24 VDC

e Valve ModelFill in the blanks below with the symbols for required specifications. SX3∗40: Internal pilot

SX3∗40R: External pilot

• Individual SUP spacer assembly: SX3000-38-3A

• Individual EXH spacer assembly: SX3000-39-3A

• SUP/EXH block assembly (Standard): SX3000-51-2A

• SUP/EXH block assembly (R): SX3000-51-6A

• SUP/EXH block assembly (S): SX3000-51-7A

• SUP/EXH block assembly (RS): SX3000-51-8A

Note) • Plug-in assembly: ZYY3000-PA

• Blanking plate assembly: SX3000-75-2A

• SUP blocking disk: SX3000-77-1A

• EXH blocking disk: SX3000-77-1A

Fill in only when the stations are more than nine or specifying wiring specifications for eight stations or less is required.

Valve stations or Layout

Eje

ctor

spe

cific

atio

nsV

alve

spe

cific

atio

ns

Noz

zle

diam

eter

07

Noz

zle

diam

eter

10

Acces

sory

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Withsilencer

Withoutsilencer

Withsilencer

Withoutsilencer

Withsilencer

WithoutsilencerWithsilencer

Withoutsilencer

With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch

Single solenoidDouble solenoidCosed centerExhaust centerPressure center

Plug-in assembly

SUP blocking diskEXH blocking disk

A, B port size (Mixed specifications)

Individual SUP spacer assemblyIndividual EXH spacer assembly

2 position

3 position

Quantity123456789101112131415

2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center

12345

Type of actuation

Nil Non-locking push typePush-locking slotted typeD

Specify using the Stations Table below.

r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)

Blanking plate assemblySUP/EXH block assemblyFill in to order

special specifications.

Two pieces usedfor one station

For SMC Use Only

Model No. Qty. Model No. Qty. Customer code

Code for person in charge

Departmental code

Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.

a

Wiringspecifications

Single wiringDouble wiring

1091

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 38: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

q Manifold ModelFill in the blanks below with the symbols for required specifications.

w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.

(Up to a total of 15 stations)Ejector/Valve stationslayout (Special specifications)

ZZYX3 45S1

Number of ejector stations1 to 7 stations

J

Total number of ejector and valve stations

SI unit mounting position

A B C

ZYX3 5 LOZD E F G H J

U side D side

n

m t

r

r

e

e w

w

q

q

Connector blockNote) Connector block is not included in the stations and layout.

Fill in the blanks in the order from q to r.

Protocol typeWithout SI unitNKE Corp.: Fieldbus SystemNKE Corp.: Fieldbus H SystemPanasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs)Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs)DeviceNetTM

OMRON Corp.: CompoBus/S (16 outputs) compatibleOMRON Corp.: CompoBus/S (8 outputs) compatibleCC-LINKCompoNetTM

Symbol0

F1HJ1J2QR1R2V

ZB

SI unit specifications

Ratedvoltage24 VDC

GOutput specifications (Vacuum switch)CNozzle diameter

DMax. vacuum pressure

ESilencer

FVacuum switch

JManifold block

HWiring specifications (Vacuum switch)

14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15

NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting

16

17

18

19

55

07 ø0.7 mmø1.0 mm10

S –84 kPa–53 kPaL

Nil NoneWith silencer1

Nil NoneWith vacuum switchE

NilNoneWith manifold block

MN

NilL

Lead wire length 0.6 mGrommettype

Connectortype

Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

CCLCN

Please copy this form and use it. (Do not detach this page.)

Manifold Valve Specification SheetZYX3000 Serial Wiring Type (Separated)DIN rail manifold

CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery

Date: / / (YY/MM/DD)

SpecificationsStandard/Internal pilot specificationExternal pilot specification

∗ : Made to order

SymbolNilR

Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS

∗ ∗

SUP/EXH block assembly specifications

A, B port size (valve only)Specifications

One-touch fitting for ø4One-touch fitting for ø6

SymbolC4C6

Mixed sizeM

2 stationsStations Note

The number of blanking plate assembly is included.

Double wiring specification8 stations

02Symbol

089 stations

15 stations

09

15

……

…… Up to 16 solenoids possible.

Specify wiring specifications using the Stations Table.

Ejector mountingposition

Mounting positionU sideD side

SymbolUD

Mounting positionU sideD side

SymbolUD

SUP/EXH block assemblymounting position

U sideMounting position Valve applicable stations

2 to 10 stations

2 to 15 stationsBoth sides

UD sideD

Symbol

BSpecial specificationsM

BManual override

ACommon specifications

Nil Positive commonNegative commonN

Nil Non-locking push typePush-locking slotted typeD

Match with the common specification of the manifold.

For special specifications, specify using the Stations Table on the next page.

For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.

1092

Page 39: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

• Individual SUP spacer assembly: SX3000-38-3A

• Individual EXH spacer assembly: SXY3000-39-3A

• SUP/EXH block assembly (Standard): SX3000-51-2A

• SUP/EXH block assembly (R): SX3000-51-6A

• SUP/EXH block assembly (S): SX3000-51-7A

• SUP/EXH block assembly (RS): SX3000-51-8A

Note) • Plug-in assembly: ZYY3000-PA

• Blanking plate assembly: SX3000-75-2A

• SUP blocking disk: SX3000-77-1A

• EXH blocking disk: SX3000-77-1A

Fill in only when the stations are more than nine or specifying wiring specifications for eight stations or less is required.

Valve stations or Layout

Eje

ctor

spe

cific

atio

nsV

alve

spe

cific

atio

ns

Noz

zle

diam

eter

07

Noz

zle

diam

eter

10

Acces

sory

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Withsilencer

Withoutsilencer

Withsilencer

Withoutsilencer

Withsilencer

WithoutsilencerWithsilencer

Withoutsilencer

With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch

Single solenoidDouble solenoidCosed centerExhaust centerPressure center

Plug-in assembly

SUP blocking diskEXH blocking disk

A, B port size (Mixed specifications)

Individual SUP spacer assemblyIndividual EXH spacer assembly

2 position

3 position

Quantity123456789101112131415

SX3 LOZ540R

A

AManual overrideRated voltage24 VDC

e Valve ModelFill in the blanks below with the symbols for required specifications. SX3∗40: Internal pilot

SX3∗40R: External pilot

2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center

12345

Type of actuation

Nil Non-locking push typePush-locking slotted typeD

Specify using the Stations Table below.

r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)

Blanking plate assemblySUP/EXH block assemblyFill in to order

special specifications.

Two pieces usedfor one station

For SMC Use Only

Model No. Qty. Model No. Qty. Customer code

Code for person in charge

Departmental code

Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.

a

Wiringspecifications

Single wiringDouble wiring

1093

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 40: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

q Manifold ModelFill in the blanks below with the symbols for required specifications.

w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.

(Up to a total of 15 stations)Ejector/Valve stationslayout (Special specifications)

ZZYX3 45S2Number of ejector stations1 to 7 stations

J

Total number of ejector and valve stationsWith transmission unitWithout transmission unit

Nil0

Unit

A B C

ZYX3 5 LOZD E F G H J

U side D side

n

m t

r

r

e

e w

w

q

q

Connector blockNote) Connector block is not included in the stations and layout.

Fill in the blanks in the order from q to r.

Ratedvoltage24 VDC

GOutput specifications (Vacuum switch)CNozzle diameter

DMax. vacuum pressure

ESilencer

FVacuum switch

JManifold block

HWiring specifications (Vacuum switch)

14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15

NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting

16

17

18

19

55

07 ø0.7 mmø1.0 mm10

S –84 kPa–53 kPaL

Nil NoneWith silencer1

Nil NoneWith vacuum switchE

NilNoneWith manifold block

MN

NilL

Lead wire length 0.6 mGrommettype

Connectortype

Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type

CCLCN

BManual override

ACommon specifications

Nil Positive commonNegative commonN

Nil Non-locking push typePush-locking slotted typeD

Match with the common specification of the manifold.

Please copy this form and use it. (Do not detach this page.)

Manifold Valve Specification SheetZYX3000 Serial Transmission Unit (For OMRON Corp.)DIN rail manifold (G71-0D16)

CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery

Date: / / (YY/MM/DD)

Mounting positionU sideD side

SymbolUD

SI unit mountingposition

SpecificationsStandard/Internal pilot specificationExternal pilot specification

∗ : Made to Order

SymbolNilR

Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS

∗ ∗ ∗

SUP/EXH block assembly specificationsA, B port size (valve only)

SpecificationsOne-touch fitting for ø4One-touch fitting for ø6

SymbolC4C6

Mixed sizeM

2 stationsStations Note

The number of blanking plate assembly is included.

Double wiring specification8 stations

02Symbol

089 stations

15 stations

09

15

……

…… Up to 16 solenoids possible.

Specify wiring specifications using the Stations Table.

Ejector mountingposition

Mounting positionU sideD side

SymbolUD

SUP/EXH block assemblymounting position

U sideMounting position Valve applicable stations

2 to 10 stations

2 to 15 stationsBoth sides

UD sideD

Symbol

BSpecial specificationsM

For special specifications, specify using the Stations Table on the next page.

For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.

1094

Page 41: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

• Individual SUP spacer assembly: SX3000-38-3A

• Individual EXH spacer assembly: SX3000-39-3A

• SUP/EXH block assembly (Standard): SX3000-51-2A

• SUP/EXH block assembly (R): SX3000-51-6A

• SUP/EXH block assembly (S): SX3000-51-7A

• SUP/EXH block assembly (RS): SX3000-51-8A

Note) • Plug-in assembly: ZYY3000-PA

• Blanking plate assembly: SX3000-75-2A

• SUP blocking disk: SX3000-77-1A

• EXH blocking disk: SX3000-77-1A

Fill in only when the stations are more than nine or specifying wiring specifications for eight stations or less is required.

Valve stations or Layout

Eje

ctor

spe

cific

atio

nsV

alve

spe

cific

atio

ns

Noz

zle

diam

eter

07

Noz

zle

diam

eter

10

Acces

sory

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Vacu

um pr

essu

re S

Vacu

um pr

essu

re L

Withsilencer

Withoutsilencer

Withsilencer

Withoutsilencer

Withsilencer

WithoutsilencerWithsilencer

Withoutsilencer

With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch

Single solenoidDouble solenoidCosed centerExhaust centerPressure center

Plug-in assembly

SUP blocking diskEXH blocking disk

A, B port size (Mixed specifications)

Individual SUP spacer assemblyIndividual EXH spacer assembly

2 position

3 position

Quantity123456789101112131415

SX3 LOZ540R

A

AManual overrideRated voltage24 VDC

e Valve ModelFill in the blanks below with the symbols for required specifications. SX3∗40: Internal pilot

SX3∗40R: External pilot

2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center

12345

Type of actuation

Nil Non-locking push typePush-locking slotted typeD

Specify using the Stations Table below.

r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)

Blanking plate assemblySUP/EXH block assemblyFill in to order

special specifications.

Two pieces usedfor one station

For SMC Use Only

Model No. Qty. Model No. Qty. Customer code

Code for person in charge

Departmental code

Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.

a

Wiringspecifications

Single wiringDouble wiring

1095

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX

Page 42: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

WiringDesign/Selection

Warning Warning

Mounting

Warning

WarningPressure Source

1. Use with the specified voltage.Use with voltage outside of the specifications can cause malfunction or switch damage, as well as electrocution and fire hazard, etc.

2. Never use a load which exceeds the maximum load capacity.This may damage a switch or reduce its service life.

3. Do not use a load that generates surge voltage.Although a zener diode for surge protection is connected at the output side of a switch, damage may still occur if the surge is applied repeatedly. When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch having a built-in surge absorbing element.

4. Be sure to confirm the fluid specifications.Since switches do not have explosion-proof construction, do not use flammable gases or fluids. This may cause a fire or explosion.

5. Be certain to observe the regulating pressure range and maximum operating pressure.Operation at a pressure outside of this range can cause failure. In addition, the switch will be broken if operated above the maximum operating pressure.

1. Confirm wire colors and terminal numbers when wiring is performed.Since incorrect wiring can lead to breakage or failure of the switch as well as malfunction, perform wiring after confirming wiring colors and terminal numbers with the instruction manual.

2. Avoid repeatedly bending or stretching lead wires.Broken lead wires will result from applying bending stress or stretching force to the lead wires. In the event that lead wires are damaged creating a possibility of malfunction, replace the entire product. (For cases in which the lead wires cannot be replaced through grommets.)

3. Confirm proper insulation of wiring.Be certain that there is no faulty wiring insulation (contact with other circuits, ground fault, improper insulation between terminals, etc.). Damage may occur due to excess currect flow into a switch.

4. Do not wire power lines or high voltage lines.Wire separately from power lines or high voltage lines, avoiding pararell wiring or wiring in the same conduit with these lines. Control circuits, including switches, may malfunc-tion due to noise from these other lines.

5. Do not allow short circuiting of loads.Use caution, as switches will be damaged instantly if a load is short circuited. Be especially careful not to reverse the power supply line (Brown) and the output line (Black).

1. Do not use until you can verify that equipment can operate properly.Verify correct mounting by suitable function and leakage inspections after air and power are connected following mount-ing, maintenance or conversions.

2. Do not drop or bump.Do not drop, bump or apply excessive impact (1000 m/s2) when handling. Even if the switch body is not damaged, the switch may suffer internal damage that will lead to malfunction.

3. Hold the product from the body side when handling.The tensile strength of the power cord is 49 N, and pulling it with a force greater than this can cause failure. Hold by the body when handling.

4. Turn the setting trimmer gently using a watchmakers screw driver.Turn the setting trimmer gently using a watchmakers screw driver. Do not turn beyond the stoppers located at both sides. If the trimmer is broken, adjustment will be impossible.

5. Pressure portDo not insert wire, etc, from the pressure port. This will damage the pressure sensor, making it impossible to obtain normal operation.

1. Observe the fluid and ambient temperature ranges. The fluid and ambient temperatures are 5 to 50°C. Moisture in circuits can freeze at 5°C or below, causing damage to O-rings, and malfunction. Consider measures to prevent freezing. The installation of an air dryer is recommended to remove drainage and moisture from circuits. Furthermore, even though the ambient temperature range remains within specifications, do not operate in locations where there are abrupt temperature changes.

2. Vacuum pressure switches There will be no change in performance if a pressure of 0.5 MPa or less is applied for 1 second or less (when releasing a vacuum), but care should be taken that pressures of 0.2 MPa or more are not regularly applied.

Series ZYY/ZYXElectronic Pressure SwitchesSpecific Product Precautions 1Be sure to read before handling.

1096

Page 43: Ejector Valve Unit ZYY3000 (Solenoid valve: SY3000) Series ZYX3000 (Solenoid valve: SX3000) Series ZYY/ZYX Ejector Valve Unit Nozzle diameter: ø0.7, ø1.0 Type S: Standard type L:

Maintenance

WarningOperating Environment

Warning

Piping Operating Environment

Caution Caution

Operation of Ejector Valves

Caution

Solenoid Valves (Series SY3000/SX3000)

Caution

Serial Wiring

Caution

Precautions

1. Never use in an atmosphere of explosive gases.The strucuture of pressure switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion.

2. Do not use in locations with sources of surge generation. When equipment that generates a large amount of surge (solenoid type lifters, high frequency induction furnaces, motors, etc.) is located in the area around a pressure switch, thers is a danger of deterioration or damage to the switch’s internal circuit elements. Therefore, implement surge countermeasures at the sources, and avoid the mixing and touching of lines.

3. Operating environmentSince the electronic pressure switch is basically an open type, avoid use in locations where there is a scattering of water or oil, etc.

1. Perform maintenance regularly. It may otherwise not be possible to assure safety due to unexpected malfunction or misoperation, etc.

2. When used in an interlock circuit When used in an interlock circuit, provide multiple interlock circuits as a precaution against failure, and also perform regular inspections to confirm normal operation.

3. When the body requires cleaning Use a soft cloth to clean the case. In case of heavy soiling, wipe it off with a cloth soaked in a neutral detergent diluted with water after wringing it out thoroughly, and finish up by wiping with a dry cloth.

1. Connect the compressed air supply piping separately to the solenoid valves and ejector valves. Also, connect each ejector valve to separate piping system.

1. When the pilot valve for air supply is turned ON, the main valve switches, and vacuum is generated by the flow of compressed air from the nozzle to the diffuser. When the pilot valve for vacuum release is turned ON, the main valve switches, and the vacuum is quickly released as air passes through the release flow adjustment needle and flows to the vacuum port. When the pilot valve for air supply and the pilot valve for vacuum release are both OFF, the main valve is in a closed state in the center position.

1. Avoid use exposed to direct sunlight.

1. Refer to Best Pneumatics No. 1 and SMC website for Specific Product Precautions for solenoid valves (Series SY3000/SX3000).

1. Serial wiring is possible only for the solenoid valve section. Wire the vacuum switch separately.

Be sure to read before handling.Refer to front matter 35 for Safety Instructions and pages 899 to 901 for Vacuum Equipment Precautions.

Series ZYY/ZYXElectronic Pressure SwitchesSpecific Product Precautions 2Be sure to read before handling.

1097

ZK2

ZQ

ZR

ZA

ZX

ZM

ZMA

ZL

ZH

ZUZYYZYXZYYZYX