Top Banner
Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics 1
31

Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Dec 25, 2015

Download

Documents

Giles Norton
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Effectiveness of Linear Spray Cooling in Microgravity

Presented by

Ben Conrad, John Springmann, Lisa McGill

Undergraduates, Engineering Mechanics & Astronautics

1

Page 2: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Heat dissipation requirements

• Remove heat fluxes of 100-1000 W/cm2

• Applicable to laser diodes, computer processors, etc.

Laser Diode Array(Silk et al, 2008)

2

Page 3: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Heat dissipation requirements

• Current Solutions– Flow boiling– Microchannel boiling– Jet impingement– Spray cooling

Spray cooling is the most promising because it achieves high heat transfer coefficients at low flow rates.

3

Page 4: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Limited previous microgravity research

• Yoshida, et al. (2001): single spray perpendicular to heated surface (100 mm away)

Microgravity significantly effects critical heat flux

14% variation in the critical heat flux from 0 to 1.8 Gs

• Sone et al. (1996): single spray perpendicular to heated surface (100 mm away)

• Golliher, et al. (2005): single spray angled 55⁰ in 2.2 sec. drop tower Significant pooling on the heated surface due largely to surface tension

4

Noted a decrease in Nusselt number with acceleration

• Yerkes et al. (2004): single spray in micro- and enhanced-gravity.

Page 5: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Spray cooling – linear array

• Single-spray systems do not cover a large area (> 1 cm2)• Regner and Shedd investigated a linear array of sprays

directed 45o onto a heated surface

• Directs fluid flow towards a defined exit to avoid fluid management issues

5

(Shedd, 2007)

Page 6: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Experiment basis & hypothesis

(Regner, B. M., and Shedd, T. A., 2007)

6

Linear spray research showed performance independent of orientation

Page 7: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Experiment basis & hypothesis

Predict that with similar spray array, spray cooling will function independent of gravity

7

Page 8: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Experiment design

Goal: determine variation of heat transfer coefficient h with gravity

q’’: heat flux measured from heater powerTs: Temperature of heated surfaceTin: Temperature of spray

8

Page 9: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Closed-loop systemPump Flow Meter

Pressure SensorBladder

Filter 3 Axis Accelerometer

Spray Box

Heat Exchanger

Pressure Sensor

Differential Pressure Sensor

Therm.

Therm.

Therm.

Therm.

Liquid coolant: FC-72

9

Page 10: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Heater design

• Ohmite TGHG 1 Ω precision current sense resistor • Four T-type thermocouples embedded in heater

25.4 mm

8.0 mm

10

Page 11: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Spray array design

Shedd, 2007

Made from microbore tubing:

11

3.2 cm

Page 12: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Spray array & spray box

12

Top half: spray array

Bottom half: heater

G

Z-direction

Fluid inlet & outlet

Page 13: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Microgravity environment

• 30 microgravity (nominally 0 g) parabolas lasting 20-25s each

• 1.8 g is experienced between microgravity

13

Page 14: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Microgravity environment

14

Page 15: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Procedure: Flow rate Q & heat flux q”

Q (L/min):0.672.673.81

15

q” (W/cm2):24.9 25.8 26.6

Very conservative heat fluxes used due to experimental nature

Page 16: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Epoxy seal failure

Epoxy cracked due to fluid pressure in pre-flight testing

Spray Array

Drain

Epoxy Failure

3.2 cm

16

Page 17: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Epoxy seal failure

17

Page 18: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Visualization shows fluid behavior

Heater

Drain

18

Camera

Page 19: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Complex fluid behavior

19

Page 20: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Flight data: flow rate dominates performance

20

Page 21: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Δh is consistent with Δg for each flow rate

• h increases with microgravity• Decreases with enhanced gravity

21

Page 22: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

h vs. jerk

Increasing variability with flow rate:

Flow rate: 0.67 L/min 2.67 L/min 3.81 L/min22

Possible Relationships

Page 23: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Shedd model for +/- 1 g

Shedd (2007) found a correlation of the form:

where the heat transfer coefficient, h, is a function of • the average spray droplet flux, Q”, and constants: • the fluid’s density, ρ,• specific heat, cp,

• Prandtl number, Pr, • an arbitrary constant, C in [m.5s-.5], for a linear spray array,• and a constant power, a.

23

Page 24: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Microgravity results fit trend

• Q” is believed to be 10-20% high due to the broken epoxy on the spray array

24

Page 25: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Future steps

• Effect of spray characteristics– Spray hole diameter and length– Hole entrance and exit design

• Enhanced surfaces with linear spray cooling?

Fluid Inlet

Nozzle diameter Nozzle

length

Nozzle edge type

25

(Kim, J. 2007)

Page 26: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Conclusion

• Flow rate Q largely determines h– 2.61 % standard deviation of h

• Support for a simple relation between h and Q– Ability to predict microgravity performance with a

1g test

• Unforeseen correspondence with jerk and Q

• Further microgravity studies are needed

26

Page 27: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Thanks

The authors are thankful to:

• the University of Wisconsin ZeroG Team

• the Multiphase Flow Visualization and Analysis Laboratory

• the UW Space, Science, and Engineering Center

• the UW Department of Engineering Physics

• the Wisconsin Space Grant Consortium

• NASA Reduced Gravity Student Flight Opportunities Program

27

Page 28: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Questions

28

Page 29: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

29

Page 30: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

FEA confirms broken array & uneven cooling

FEA confirms the rupture caused uneven temperatures:

Cross-section:

Side with rupture, Side with spray cooling less cooling

Top down:

30

Page 31: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

31