EE 5340/7340, SMU Electrical Engineering Department, © 2005 1 Electrocardiogram (ECG) Generated in the heart amplitude range: 0.5 - 4 mV frequency range: 0.01-250 Hz measurement: surface electrodes
24

EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

Dec 28, 2015

Download

Documents

Jerome Harper
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 1

Electrocardiogram (ECG)

Generated in the heart amplitude range: 0.5 - 4 mV frequency range: 0.01-250 Hz measurement: surface electrodes

Page 2: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

2 EE 5340/7340, SMU Electrical Engineering Department, © 2005 2

Structure of Heart heart chambers

r. atrium, l. atrium r. ventricle, l. ventricle

heart valves tricuspid (RA:RV) Mitral (LA:LV) semilunar (RV:pulm. art.) aortic (LV:aorta)

Page 3: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 3

Structure of Heart (cont.)

RA

RV

sup. vena cava

pulmonary art.

LA

LV

lungs

pulmonary v.

aorta

coronary arteries

coronary sinus

Page 4: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 4

Conductive Tissues in Heart

sino-atrial (SA) node internodal tracts AV node Bundle of His Purkinje fibers

} atria

} ventricles

Page 5: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 5

Cardiac Cycle

venous blood enters LA, passes through TC valve to RV RV contracts, TC valve closes. pulm. valve opens, blood goes to lungs via pulm. art. blood enters LA through pulm. vein, passes through open

mitral valve to LV LA contracts, mitral valve closes, aortic valve opens,

blood goes to aorta. 2 atria contract nearly simultaneously (RA contracts a bit

earlier) 2 ventricles contract simultaneously.

Page 6: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 6

Cardiac Output and Chamber Pressures

typically 5 l/min 70-80% total blood volume in veins 20% in arteries remainder in capillaries systolic (max) pressure: 95-140 mm Hg (120 average) diastolic (min) pressure: 60-90 mm Hg (80 average) LV: 130/5 mm Hg (sys/dias) LA: 9/5 mm Hg RV 20/5 mm Hg RA: 3/0 mm Hg

Page 7: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 7

Electrocardiogram Features

P

Q

R

S

T

0.6s

P: atrial depolarization QRS: ventricular depolarization T: ventricular repolarization

typical heart rate: 72 BPM

Page 8: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 8

Lead Configurations for ECG Measurement

Bipolar Leads Augmented Leads Chest (V) Leads

Page 9: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 9

Bipolar Leads: lead I

+ _

vo

+

_

Page 10: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 10

Bipolar Leads: lead II

+ _

vo

+

_

Page 11: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 11

Bipolar Leads: lead III

+ _

vo

+

_

Page 12: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 12

Augmented Leads: aVR

+ _

vo

+

_

Page 13: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 13

Augmented Leads: aVL

+ _

vo

+

_

Page 14: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2005 14

Augmented Leads: aVF

+ _

vo

+

_

Page 15: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2004 15

Unipolar Chest Leads

v1 v2

v3

v4

v5 v6

v1: fourth intercostal space, at right sternal margin. v2: fourth intercostal space, at left sternal margin. v3: midway between v3 and v4. v4: fifth intercostal space, at mid clavicular line. v5: same level as v4, on anterior axillary line. v6: same level as v4, on mid axillary line.

Page 16: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2004 16

Unipolar Chest Leads (cont.)

+ _ +

_

Page 17: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2004 17

ECG Lead Color Codes

C (brown)

LA (black)

LL (red)RL (green)

RA (white)

Page 18: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2004 18

Surface Cardiac Potentials

taken at t = to suggests an equivalent dipole located within the heart

Page 19: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2004 19

Eindhoven’s Triangle

-very crude solution to inverse problem using bipolar limb leads:

RA LA

LL

_

_

+

_

++

lead II

lead I

lead III

Page 20: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2004 20

Abnormal ECG Rhythms

Complete Heart Block (AV Block): -atria and ventricles contract independently

P P P P

+

=

RT T TRR

P

R

T P

RT P

Page 21: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2004 21

Abnormal ECG Rhythms (cont.)

First Degree AV Block: increased AV node delay, get increased P-R intervals.

Second Degree Block: get one QRS complext for every two P waves.

heart block can be treated with drugs, artificial pacemakers.

P PP

R

T

Page 22: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2004 22

Ectopic Focus PVC’s

Ectopic Focus: region of ischemic cardiac tissue that becomes injured, depolarizes spontaneously, may cause an entire ventricular contraction:

PVC

also called extrasystole

Page 23: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2004 23

Tachycardia (Rapid Heart Rate)

ectopic focus can also discharge repeatedly producing ventricular (paroxysmal) tachycardia:

all QRS complexes

if etopic focus is located in atrium, can get atrial flutter:

P P P P P

R R

P P P P

Page 24: EE 5340/7340, SMU Electrical Engineering Department, © 20051 Electrocardiogram (ECG) n Generated in the heart n amplitude range: 0.5 - 4 mV n frequency.

EE 5340/7340, SMU Electrical Engineering Department, © 2004 24

Tachycardia (Rapid Heart Rate)

ectopic focus can also discharge repeatedly producing ventricular (paroxysmal) tachycardia:

all QRS complexes

if etopic focus is located in atrium, can get atrial flutter:

P P P P P

R R

P P P P