Page 1: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Education You Can Build On

Classic 80 Series Thermostats

Homeowner Support Hotline: 800-284-2925

Education CentralEngage, Apply, Retain

Note: This module covers common elements. Refer to Specification Sheet or Installation Instructions for

detailed information.

Page 2: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Application Coverage by System Model

Stages Heat / Cool by System

Applications Programming Options Power Source

Single Stage (SS) Multi-Stage (MS) Heat Pump (HP1 or HP2)

Universal (All)

Model Number

Single Stage

Multi-Stage

Heat

Pump

Gas/Oil/Electric

3-Wire Zon

e Valu

e

Millivolt Compatible

Humidity Control

Program Days per Week

Program Periods per Day

Hardwire Battery Power Assist

Universal1F85-277 1/1 2/2 3/2 ✓   ✓   7, 5+1+1, Ø 4, 2, Ø B,H

1F85RF-275 1/1 2/2 3/2 ✓   ✓   5+1+1, Ø 4, 2, Ø PS,H

Single Stage / Heat Pump1F87-361 1/1   1/1 ✓   ✓   7-day 4 B,H

1F80-361 1/1   1/1 ✓   ✓   5+1+1 4 B,H

Multi-Stage 1F81-261   2/2   ✓       5 +1+1 4 B,H

Heat Pump 1F82-261     2/1 ✓       5+1+1 4 H

Single Stage / Heat Pump 1F86-344 1/1   1/1 ✓   ✓   Ø Ø B,H

Multi-Stage 1F83-261   2/2   ✓       Ø Ø B,H

Heat Pump 1F89-211     2/1 ✓       Ø Ø H

Classic 80 Series ThermostatSelecting the Right Thermostat for the Job

Page 3: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series Thermostats Agenda

• Applications

• Wiring

• Configuration

• Programming

Featured Products in Module– 1F85-277

• Multi Stage / Programmable– 1F86-344

• Single Stage / Non-Programmable

Page 4: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Staging By System TypeProgramming OptionsApplications

Terminal Identification Part Number

Look at the Box for Detailed Information

Page 5: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series Thermostat Overview

• Single Stage or Two Stage Heat Pump

• Classic Look

• Comfort Alert™ Compressor Protection

• Battery Power Monitor

• Choice of Programmable or Non-Programmable

• +/-1 Degree Accuracy- For Optimum Comfort and Equipment Life

Value, performance, reliability, installer confidence and east of use have made White-Rodgers 80 Series the most trusted and best-selling digital thermostats in the industry…and they still are.

Page 6: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 SeriesSpecification Sheets Contain Detailed Information

Page 7: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series Applications

Application StagesProgramming Type

Conventional or Heat Pump with No Aux

1/1

0 1F86

5+1+1 1F80

7 1F87

Conventional Only 2/20 1F83

5+1+1 1F81

Heat Pump Only With Aux 2/10 1F89

5+1+1 1F82

Universal 3/2 7, 5+1+1, 0 1F85

Page 8: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series Terminal Designations Classic 80

Conventional Heat Pump Universal

CONV or HP/No Aux * CONV Only HP Only With Aux/Emer ** All

Terminal Description 1F80-361

1F86-344

1F87-361

1F81-261

1F83-261

1F82-261

1F89-211 1F85-277

 Programming 5+1+1 0 7 5+1+1 0 5+1+1 0 7, 5+1+1, 0Stages 1/1 2/2 2/1 3/2

W 1st Stage Heat ● ●    

E/W1 1st. Stage Heat or Aux 1st Stage for HP

      ●

E Emergency Heat Relay     ●  

W2 2nd Stage Heat or Aux 2nd stage HP2

  ● ● ●

Y 1st Stage Compressor ● ● ●  Y1 1st Stage Compressor               ● Y2 2nd Stage Compressor   ●   ●

O/B Reversing Valve Combined

    ●  

O and B Reversing Valve Separate

●     ●

G Fan Relay ● ● ● ●

R 24 VAC Hot (TH) Combined

  ● ● ●

RH and RC 24 VAC Hot (TH) Separate

●      

C 24 VAC Common (TR) Wire

● ● ● ●

L Diagnostics     ● ●

Notes:* Requires Field Wiring from Y

to W for Heat Pump  

** Heat Pump Only Y is 1st Stage Heat  

Page 9: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

• FAN (GAS/ELEC) Fan Operation– GAS position lets the equipment operate the fan on a call for heat– ELEC position lets the thermostat operate the fan on a call for heat—you will use

this position for heat pumps or electric furnaces.• Switch 1F80, 1F81, 1F83, 1F85, 1F86, 1F87• Jumper 1F82,1F89

• O/B (Reversing ValveSwitch-(1F82 and 1F89)– When used on a heat pump determines if reversing is energized in cooling “O” or

energized in heating “B” (If you have a separate “O” or “B” terminal wire directly)

Classic 80 Series Application Selection

There are two different Heat Pump terminals on the Classic 80

- Requires using the switch on the back of the thermostat

- Requires traditional wiring

Page 10: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series Conventional

• 1F81, 1F83 Conventional Only no Heat Pump Conversion

• 1F80, 1F86, 1F87 Conventional That Can Be Converted to Heat Pump No Aux With Field Wiring

Field Installed Jumper option to convert to a single stage heat pump with no auxilliary heat

Page 11: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series Heat Pump 1F82 and 1F89 With Aux/Emergency

• Field installed jumper between “W2” and “E” required to use a single Aux Heat for both Second Stage Heat and Emergency

Page 12: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series Universal (1F85)Conventional Single or Multi-Stage

Heat Pump Single or Multi-Stage

Page 13: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series Navigation

Day of Week

Time of Day

Fan/AutoTemperature Hold

Temperature or ConfigAdjustment Buttons

Actual Room Temperature

Desired Temperature

Run Program

Enter Program

Set Time

Heat/Cool/Off Button

Page 14: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series Entering System Configuration

Most technical service calls are the result of improper system configuration

1. System must be in OFF Mode

2. Press the Up and Down button simultaneously

Record settings of key items for Homeowner Reference

Page 15: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Configuration 1F82 and 1F89 (Heat Pumps)

Step 1F82 1F89 Displayed Press Comments

1 PRGM

and RUNSet SYSTEMswitch to OFF

HOLD (0:00)0 to 8 hrs (in

15 minute increments) Select Temporary Hold time

2 HOLD* Δ or SLFA Select FA or SL (Fast or Slow) pump cycle rate

3 HOLD* Δ or

EMER FA SLSelect FA or SL (Fast or Slow) Auxiliary and Emergency

Aux heating cycle rate

4 HOLD* Δ or D-L OFF Select display backlight

5 HOLD* Δ or E (on) OFF Select Energy Management Recovery

6 HOLD* Δ or Filter (000) 0 TO 1950 Hours Select Filter Replacement Time in 50 Hr. Increments

7HOLD*

Δ or LOC (OFF) ON Select Compressor Lock Out

8HOLD*

Δ or 0 HI (0) 4 LO to 4 HI Select temperature display adjustment higher or lower

9HOLD*

Δ or °F °C Select temperature display °F or °C

10HOLD*

Δ or FA (ON) OFF Select fast second stage ON or OFF

11 RUN Return to normal operation

Page 16: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Configuration 1F85 (Universal, SS-MS-HP) 1F85 Menu Reference Number

Displayed (Factory Default)

Press Δ or to Select From Listed Options

Comments (Press System Button to Advance)

1 MS 2 HP1, HP2, SS1Selects Multi-Stage, Heat Pump 1 (1 Compressor), Heat Pump 2(2 Compressor or 2 Speed Compressor), or Single Stage

2 (7) 5d, 0d Selects Number of Programs per Week

3 PRG 4 PRG 2, PRG 0 Selects Programmable Periods

4 4:00 HOLD0:15 to 8:00 (increments of

15 minutes)Selects Temporary Program Override Time, Maximum setting is 4:00 hours

5 EMR (on) OFF Selects Energy Management Recovery OFF or ON

6 FA SL Selects Fast or Slow Cycle Selection

7 CL (OFF) CL on Selects Compressor Lockout CL OFF or ON

8 CdL (on) CdL OFF Selects Backlight Display

9 FA (on) FA OFF Selects Fast Second Stage ON or OFF

10 0 FLTR 50-1950 Selects filter replacement run time

110 (RoomTemp)

4 LO to 4 HI Selects Selects Temperature Display Adjustment 4 LO to 4 HI

12 F C For Centigrade selection

13 AU (on) AU OFF Selects Auto Mode ON or OFF

14 LR (90) LR 62 to LR 89 Selects Limited HEAT range

15 LR (45) LR 46 to LR 82 Selects Limited COOL range

16 (OFF) on Selects Keypad Lockout

17 000 If L/O 001 to 999 Selects Keypad Lockout combination. Press System to set code

18     Returns to the OFF position

Page 17: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Configuration 1F80, 1F81,1F83, 1F86, 1F87 (Conventional SS, MS or HP w/o Aux Heat)

1F80/87 1F81 1F83/86Displayed

(Factory Default)Press Δ or or Hold toSelect Comments

PRGMand RUN

PRGMand RUN

Set SYSTEMSwitch to OFF

1 1 n/a HOLD (0:00)0 to 8 hrs (in

15 minute increments)Select temporary Hold time

2 2 2 (FA) SLSelect FA or SL (Fast or Slow)

heating cycle rate

3 3 3 d-L (ON) OFF Select display backlight OFF or ON

4 4 n/a E (ON) OFFSelect Energy Management

Recovery OFF or ON

5 5 4Filter(000)

0 to 1950 hours(in 50 hour increments)

Select filter replacement run time

6 6 5 LOC (OFF) ONSelect Compressor lockout OFF or

ON

7 7 6 0 HI (0)4 LO to

4 HISelect temperature display adjustment higher or lower

8 8 7 °(F) °CSelect temperature display to °F or

°C

9 1 + 2 FA OffSelect ON to start 2nd stage

immediately when the setpoint is manually changed 3°

Page 18: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series Programming Worksheet

Technical Service has never spoken to anyone who could not program the thermostat once they filled out the schedule worksheet in the manual and KEPT it. Save a call back and fill it out the form from the homeowners manual with the homeowner. Ensure they have the Homeowner Support Hotline: 800-284-2925

Verify

Page 19: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

1. TIME button.2. PRGM (program) button.3. RUN (program) button4. HOLD temperature button5. FAN switch (ON, AUTO).6. SYSTEM switch COOL, OFF, HEAT, EMER7. Raises temperature setting.8. Lowers temperature setting.

Classic 80 SeriesThermostat Buttons and Switches

7

8

32

1

65

NOTE: TIME, PRGM and RUN/HOLD buttons not on non-programmable models.

4

Page 20: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series Set Time and Day

Set Current Time and Day1. Press TIME button once. The display will

show the hour only2. Press and hold either UP or DOWN until

you reach the correct hour and AM/PM designation (AM begins at midnight; PM begins at noon)

3. Press TIME once again. The display window will show the minutes only.

4. Press and hold either UP or DOWN until you reach the correct minutes.

5. Press TIME once again. The display will show the day of the week.

6. Press UP or DOWN until you reach the current day of the week.

7. Press RUN/HOLD once. The display will show the correct time, day, room temperature and set-point temperature.

Page 21: Education You Can Build On Classic 80 Series Thermostats Homeowner Support Hotline: 800-284-2925 Education Central Engage, Apply, Retain Note: This module.

Classic 80 Series How To Set A Program1. Move the SYSTEM switch to Heat or Cool2. Press PRGM once. “Mo Tu We Th Fr” (indicating weekday

program) will appear in the display. 3. Press UP or DOWN to change the displayed temperature to

your selected temperature for the 1st program period.4. Press TIME once (the programmed time will flash). Press UP

or DOWN until your selected time appears. The time will change in 15 minute increments. When your selected time is displayed, press TIME again to return to the change temperature mode.

5. Press PRGM once. The currently programmed start time and setpoint temperature for the 2nd program period will appear.

6. Repeat steps 3 and 4 to select the start time and temperature for the 2nd program period.

7. Repeat steps 3 through 5 for the 3rd and 4th program periods.8. Press PRGM once. “SA” (indicating Saturday program) will

appear in the display, along with the start time for the 1st period and the currently programmed temperature.

9. Repeat steps 3 through 7 to complete Saturday programming.10.Press PRGM once to change to SU (Sunday) programming

and repeat steps 3 through 7 to complete Sunday programming.

11.When you have completed entering your program ,press RUN/HOLD.