Top Banner
FAU-TDL WWW.ECOTECCO.COM FAU-TDL Laser Technology Now Available The FAU-TDL uses Tunable Diode Laser Technology to enable accurate and reliable measurements with no drift over time or cross gas sensitivity. This analyzer is the most reliable and cost effective solution for Carbon Credit verification and Green House Gas (GHG) reporting. Tunable Diode Laser Technology No drift over time/No cross gas contamination Annual Factory Calibration Not Required FIELD ANALYTICAL UNIT TUNABLE DIODE LASER
2

Ecotec FAU TDLv1 - Welcome to ECOTECecotecco.com/wp-content/uploads/2016/08/Ecotec_FAU_TDL.pdf · FAU-TDL O T E CCO.CO M FAU-TDL Laser Technology Now Available The FAU-TDL uses Tunable

Mar 31, 2018

Download

Documents

doannhan
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Ecotec FAU TDLv1 - Welcome to ECOTECecotecco.com/wp-content/uploads/2016/08/Ecotec_FAU_TDL.pdf · FAU-TDL O T E CCO.CO M FAU-TDL Laser Technology Now Available The FAU-TDL uses Tunable

FAU-TDL

W W W . E C O T E C C O . C O M

FAU-TDL Laser TechnologyNow Available

The FAU-TDL uses Tunable Diode Laser Technology to enable accurate andreliable measurements with no drift over time or cross gas sensitivity.

This analyzer is the most reliable and cost effective solution forCarbon Credit verification and Green House Gas (GHG) reporting.

Tunable Diode Laser Technology

No drift over time/No cross gas contamination

Annual Factory Calibration Not Required

FIELD ANALYTICAL UNITTUNABLE DIODE LASER

Page 2: Ecotec FAU TDLv1 - Welcome to ECOTECecotecco.com/wp-content/uploads/2016/08/Ecotec_FAU_TDL.pdf · FAU-TDL O T E CCO.CO M FAU-TDL Laser Technology Now Available The FAU-TDL uses Tunable

Features• Tunable Diode Laser Technology• Measures % CH4, CO2 & O2

wavelength (CH4 & CO2)• Accuracy of 1.0% full scale (CH4, CO2 & O2)• No drift overtime (CH4 & CO2)• Optically isolated analog outputs - 4-20mA

• Options: Rack mounted or NEMA 4x enclosure• Optional: Gas Conditioning unit-with e�ciency of 99.97% removal of (0.3-06 micron particles)• Optional: Temperature Probe

• Accurate & reliable measurements• No cross gas contamination• Fixed position continuous analyzer• Continuous readings with rapid response• Integrates to AEMS or existing SCADA Systems• Low cost of ownership

• Green House Gas/Carbon Credit Projects (CDM, CAR, CCX, REGGI, GSV2, VCS)• Gas to energy projects• Environmental compliance projects• Closed site monitoring

Applications

Technical Specification

ECOTEC SOLUTIONS, INC.850 South Via Lata, Suite 112

Colton, CA 92324 Phone +1 (909) 906-1001

© ECOTEC SOLUTIONS, INC. 2015 #CTS-FAUTDL Rev 8-2016

www.ecotecco.com

FAU-TDLFIELD ANALYTICAL UNITTUNABLE DIODE LASER

Power SupplyPower Requirements

90-240 VAC, 50-60 Hz 1.4A

Gas RangesGases Measured CH4

CO2

By Tunable Diode Laser

O2 By internal electrochemical cell

0-100% 0-25%

0-100% Ranges

Gas Accuracy

By Tunable Diode Laser

CH4CO2O2

± 1.0%± 1.0%

± 1.0%CH4CO2O2

Gas ConditioningCan sample on wet or dry basis:gas must be non-condensing

Particles > 20 micronsParticle removal

Response Time, T90

Liquid removal

PumpFlow Rate 200-1000 ml/minVacuum / Pressure -120” W.C. Max /

+4 PSI Max

Environmental ConditionsAmbient TemperatureRange Relative Humidity

-4°F to 158oF (-20°C to +70oC)

0-95% non condensing

Optional AccessoriesTemperature Probe ±1oC of reading -22oF to 266oF

(-30oC to +130oC)

Physical

19” Rack MountDimentions and Weight7”H x 19”W x 18”D (178mm x 483mm x 457mm) - 31 lbs (14kg)

NEMA 4x enclosure 25.4”H x 17.1”W x 9.8”D (645mm x 434mm x 249mm)

The development of ECOTEC’s FAU-TDL is the culmination of research by NASA’s Jet Propulsion Laboratory for use on Mars. The optical

This technique produces an analyzer with a fast response speed, where the laser light stimulates vibrations and rotation in the molecule, resulting in energy absorption and enabling the sensing of gas.