Economical utilization of coal bed methane emitted during exploitation of coal seams – energetic and environmental aspects President of The Board mgr inż. Roman Łój Katowicki Holding Węglowy S.A.
Economical utilization of coal bed methane emitted
during exploitation of coal seams
– energetic and environmental aspects
President of The Board
mgr inż. Roman Łój
Katowicki Holding Węglowy S.A.
The share of KHW S.A. in hard coal extraction in Poland in 2012 year
Katowicki Holding Węglowy S.A. – significant coal producer in Poland (UE)
Extraction of steam hard coal in Poland in 2012 year.
( % of share)
17,48%
11,72%
6,02%
6,28%2,75%
55,75%
Kompania Węglowa
Katowicki Holding Węglowy
LW Bogdanka
Południowy Koncern Węglowy
Jastrzębska Spółka Węglowa
Pozostałe
Extraction of hard coal in Poland in 2012 year.
( % of share)
50,27%
17,23%
14,85%
9,96%
5,12%
2,57%
Kompania Węglowa
Jastrzębska Spółka Węglowa
Katowicki Holding Węglowy
LW Bogdanka
Południowy Koncern Węglowy
Pozostałe
KWK „Murcki-Staszic”
KWK „Wieczorek”,
KWK „Mysłowice-Wesoła”
KWK „Wujek”
KWK „Kazimierz-Juliusz” Sp. z o.o.
Structure of Katowice Capital Group
Katowicki Holding Węglowy SA
KGK
Zakłady Energetyki Cieplnej
Katowicki Węgiel
Spółka Mieszkaniowa
Spółka Szkoleniowa
Common Services Center
MIN
ES
KHW S.A. – chosen economical and technical data
(2012 year)
Coal production: 11,6 mil. tons Coal export: 630 mil. tons Value of investments: 680 mil. PLN Sales income: 3 807,6 mil. PLN Employment: ~ 17,5 ths. persons Coal bed methane sales income: ~ 2,690 mil. PLN
5
KHW S.A. – chosen economical and technical data
(2012 year and 10 months of 2013 year)
2012 10 months 2013
Energetic use of methane
in installations of ZEC S.A. 10,24 mil. m3 15,4 mil. m3
Thermal energy production
from methane (ZEC S.A.): 183 ths. GJ 313 ths. GJ
Electrical energy production
from methane (ZEC S.A.): 21 GWh 39 GWh
Economical effect of using electrical energy
produced from methane in KHW S.A.: 690 ths. PLN 895 ths. PLN
Reduction of emmission of CO2 equivalent ~ 182 ths. tons ~ 260 ths. tons
Chosen coal bed methane data in mines of KHW S.A. (2012 year)
Quantity of methane emitted during exploitation of coal seams: 131,28 mil. m3
including:
- emitted to the atmosphere (by ventilation): 108,89 mil. m3
- captured in surface drainage stations: 22,39 mil. m3
- energetically used in installation of Thermal Energy Plants: 10,24 mil.m3
Reduction of emission to the atmosphere (equivalent of CO2) ~ 182 ths. tons
The example of effective methane drainage of coal seam
ŚCIANA 514 pokł. 501 partia
Az
Długość ściany
[m]
Wysokość ściany
[m]
Śr. wydobycie
[t/d]
225 do 3,8 m 3000
KWK „Mysłowice – Wesoła”:
Methane drainage station
Capture of methane - 41,30 m3/min
Utilization of methane by energy production
plants (ZEC) - 80%
Present absolute metanovelty of wall 514 in seam
501 part Az - 35,51 m3/min
Ventilation metanovelty - 10,80 m3/min
Methane drainage - 24,71 m3/min
Methane drainage efficiency for wall 514
region vary 50 – 70%.
It is the best result in KHW S.A. and one of the
best in polish deep hard coal mines.
Management of coal bed methane captured in drainage
stations
Captured in drainage stations mine methane gas is and will be used by dependent
company Zakłady Energetyki Cieplnej S.A. (Thermal Energy Plants) for production
of electrical energy and heat (also for production of cold in future) with the
environmental effect of reduction of greenhouse gases emmision to the atmosphere
Existing installations using coal bed methane
ZEC S.A. division No. V – „Wieczorek”
Number of engines
2 pcs
Rated power
2 x 1,485 MWe
1,615 MWt
Number of boilers
1 pc.
Boiler type and power
LOOS- 6MWt
ZEC S.A. division No. IX – „Wesoła"
Number of engines
2 pcs
Rated power
2 x 1,403 MWe
1,479 MWt
Number of boilers
4 pcs.
Boiler type and power
WR-10 - 11,6 MWt
WLM-5 - 5,8 MWt
PWPg-06 - 0,7 MWt
PWPg-06 - 0,7 MWt
Planned by ZEC S.A. in 2014 – 2018 years investments
developing network of installed gas engines with generators
and gas boilers for energetic use of methane
ZEC S.A.
division No. IX –
„Wesoła"
Number of engines
3 pcs.
Rated power
2 x 2,68 MWe
+
1,4 MWe
ZEC S.A.
division No. XII –
„Śląsk"
Number of engines
5 pcs
Rated power
5 x 1,48 MWe
+
Quantity of boilers
1 pc
Boiler power
6 MWth
ZEC S.A.
division No. VI -
„Wujek"
Number of engines
2 pcs
Rated power
2 x 1,48 MWe
ZEC S.A.
division No. V –
„Wieczorek”
Number of engines 1
pc
Rated power
1,48 MWe
Total methane utilization: ~ 60 mil. m3/year
It will cause reduction of greenhouse gases emission equivalent to ~ 1 mil tons of
CO2/year
ZEC S.A.
division No. IV –
„Murcki”
Number of engines
2 pcs
Rated power
2 x 1,48 MWe
Quantity of boilers
1 pc
Boiler power
6 MWth