BOUND ARY 40.23 m BOUNDARY 15.24 m BOUND ARY 40.23 m BOUNDARY 15.24 m LAMONT STREET EX D RIVEW A Y NEIGHBOURING RESIDENCE NEIGHBOURING RESIDENCE NEIGHBOURING RESIDENCE SHED NEIGHBOURING RESIDENCE SHED PROPOSED NEW ANCILLERY DWELLING & DOUBLE GARAGE EXISTING RESIDENCE 100.00mm 100.177mm 100.193mm 100.228mm 100.151mm 100.283mm 100.246mm 100.271mm 100.3111mm 100.304mm 100.416mm 100.565mm 100.556mm 100.516mm NEW D R I V E W AY BY O WNER 272 2 2197 2380 EXISTING SHED TO BE REMOVED 1941 10 00 Drafted by: Approved By: Scale: Revision: Date: Project/Drawing No: Drawing: NOTE: DO NOT SCALE OFF DRAWINGS Project: Client name: 10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.au Accredited building practitioner: Frank Geskus No CC246A 1 : 200 F.G.G. E.R.G. SITE PLAN PD18119 01 21/05/2018 PLANNING P REL IM INA R Y P RIN T PROPOSED ANCILLARY DWELLING 15 LAMONT STREET INVERMAY DB INVESTMENTS 03 LOT No. LOT AREA 50% 25% 613 306 153 1 : 200 SITE PLAN GENERAL NOTES CHECK & VERIFY ALL DIMENSIONS & LEVELS ON SITE WRITTEN DIMENSIONS TO TAKE PREFERENCE OVER SCALED ALL WORK TO BE STRICTLY IN ACCORDANCE WITH NCC, ALL S.A.A.. CODES & LOCAL AUTHORITY BY-LAWS ALL DIMENSIONS INDICATED ARE FRAME TO FRAME AND DO NOT ALLOW FOR WALL LININGS CONFIRM ALL FLOOR AREAS ALL PLUMBING WORKS TO BE STRICTLY IN ACCORDANCE WITH A.S. 3500 & APPROVED BY COUNCIL INSPECTOR BUILDER/PLUMBER TO ENSURE ADEQUATE FALL TO SITE CONNECTION POINTS IN ACCORDANCE WITH A.S. 3500 FOR STORMWATER AND SEWER BEFORE CONSTRUCTION COMMENCES THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE ENGINEER'S STRUCTURAL DRAWINGS ALL WINDOWS AND GLAZING TO COMPLY WITH A.S. 1288 & A.S. 2047 ALL SET OUT OF BUILDINGS & STRUCTURES TO BE CARRIED OUT BY A REGISTERED LAND SURVEYOR AND CHECKED PRIOR TO CONSTRUCTION IF CONSTRUCTION OF THE DESIGN IN THIS SET OF DRAWINGS DIFFER FROM THE DESIGN AND DETAIL IN THESE AND ANY ASSOCIATED DOCUMENTS BUILDER AND OWNER ARE TO NOTIFY DESIGNER BUILDER'S RESPONSIBILITY TO COMPLY WITH ALL PLANNING CONDITIONS BUILDER TO HAVE STAMPED BUILDING APPROVAL DRAWINGS AND PERMITS PRIOR TO COMMENCEMENT OF CONSTRUCTION CONSTRUCTION TO COMPLY WITH AS 3959, READ IN CONJUNCTION WITH BUSHFIRE ATTACK LEVEL (BAL) ASSESSMENT REPORT. THIS PROJECT HAS BEEN DETERMINED TO HAVE A BUSHFIRE ATTACK LEVEL (BAL) OF - ?? REFER TO ASSESSMENT FOR FURTHER DETAILS. ALL CONSTRUCTION MUST COMPLY WITH 3959. Version: 1, Version Date: 22/05/2018 Document Set ID: 3805865 PLANNING EXHIBITED DOCUMENTS Planning Administration 0276/2018 Ref. No: DA Date advertised: 09/06/2018 This document is subject to copyright and is protected by law. In displaying this document on its website the Council grants website users a non-exclusive licence to reproduce the document in their web browser for the sole purpose of viewing the content. The Council reserves all other rights. Documents displayed on the Council's website are intended for public perusal only and should not be reproduced without the consent of the copyright owner. Version: 2, Version Date: 07/06/2018 Document Set ID: 3818249 Version: 1, Version Date: 18/07/2018 Document Set ID: 3846074
5

ECM 3846074 v1 DA0276/2018 - Other Files - Attachment 2 - … · 2018-07-24 · PROPOSED NEW ANCILLERY DWELLING & DOUBLE GARAGE EXISTING RESIDENCE 100.00mm 100.177mm 100.193mm 100.228mm

Jul 13, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ECM 3846074 v1 DA0276/2018 - Other Files - Attachment 2 - … · 2018-07-24 · PROPOSED NEW ANCILLERY DWELLING & DOUBLE GARAGE EXISTING RESIDENCE 100.00mm 100.177mm 100.193mm 100.228mm

BOUN

DARY 4

0.23 m

BOUN

DAR

Y 15.24

m

BOUN

DARY 4

0.23 m

BOUN

DAR

Y 15.24

m

LAMONT

STR

EET

EX D

RIV

EWAY

NEIGHBOURING

RESIDENCE

NEIGHBOURING

RESIDENCE

NEIGHBOURING

RESIDENCE SHED

NEIGHBOURING

RESIDENCE SHED

PROPOSED NEW ANCILLERY

DWELLING & DOUBLE GARAGE

EXISTING RESIDENCE

100.00mm

100.177mm

100.193mm

100.228mm

100.151mm

100.283mm

100.246mm

100.271mm

100.3111mm

100.304mm

100.416mm

100.565mm

100.556mm

100.516mm

NEW

DRIVEW

AY B

Y O

WNER

272

2

2197

2380

EXISTING SHED TO

BE REMOVED

1941

1000

Drafted by: Approved By:

Scale:

Revision:

Date:

Project/Drawing No:

Drawing:

NO

TE

: D

O N

OT

SC

AL

E O

FF

DR

AW

ING

S

Project:

Client name:

10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.auAccredited building practitioner: Frank Geskus No CC246A

1 : 200

F.G.G.E.R.G.

SITE PLAN

PD18119 01

21/05/2018

PLANNING

PRELI

MIN

ARY P

RIN

T

PROPOSED ANCILLARYDWELLING15 LAMONT STREETINVERMAY

DB INVESTMENTS

03LOT No. LOT AREA 50% 25%

613 306 153

1 : 200

SITE PLAN

GENERAL NOTES

• CHECK & VERIFY ALL DIMENSIONS & LEVELS ON SITE

• WRITTEN DIMENSIONS TO TAKE PREFERENCE OVER SCALED

• ALL WORK TO BE STRICTLY IN ACCORDANCE WITH NCC, ALL

S.A.A.. CODES & LOCAL AUTHORITY BY-LAWS

• ALL DIMENSIONS INDICATED ARE FRAME TO FRAME AND DO

NOT ALLOW FOR WALL LININGS

• CONFIRM ALL FLOOR AREAS

• ALL PLUMBING WORKS TO BE STRICTLY IN ACCORDANCE

WITH A.S. 3500 & APPROVED BY COUNCIL INSPECTOR

• BUILDER/PLUMBER TO ENSURE ADEQUATE FALL TO SITE

CONNECTION POINTS IN ACCORDANCE WITH A.S. 3500 FOR

STORMWATER AND SEWER BEFORE CONSTRUCTION

COMMENCES

• THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE

ENGINEER'S STRUCTURAL DRAWINGS

• ALL WINDOWS AND GLAZING TO COMPLY WITH A.S. 1288 &

A.S. 2047

• ALL SET OUT OF BUILDINGS & STRUCTURES TO BE CARRIED

OUT BY A REGISTERED LAND SURVEYOR AND CHECKED

PRIOR TO CONSTRUCTION

• IF CONSTRUCTION OF THE DESIGN IN THIS SET OF DRAWINGS

DIFFER FROM THE DESIGN AND DETAIL IN THESE AND ANY

ASSOCIATED DOCUMENTS BUILDER AND OWNER ARE TO

NOTIFY DESIGNER

• BUILDER'S RESPONSIBILITY TO COMPLY WITH ALL PLANNING

CONDITIONS

• BUILDER TO HAVE STAMPED BUILDING APPROVAL

DRAWINGS AND PERMITS PRIOR TO COMMENCEMENT OF

CONSTRUCTION

• CONSTRUCTION TO COMPLY WITH AS 3959, READ IN

CONJUNCTION WITH BUSHFIRE ATTACK LEVEL (BAL)

ASSESSMENT REPORT.

THIS PROJECT HAS BEEN DETERMINED TO HAVE A

BUSHFIRE ATTACK LEVEL (BAL) OF - ??

REFER TO ASSESSMENT FOR FURTHER DETAILS.

ALL CONSTRUCTION MUST COMPLY WITH 3959.

Version: 1, Version Date: 22/05/2018Document Set ID: 3805865

PLANNING EXHIBITEDDOCUMENTS

Planning Administration

0276/2018Ref. No: DA

Dateadvertised: 09/06/2018

This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.

Version: 2, Version Date: 07/06/2018Document Set ID: 3818249Version: 1, Version Date: 18/07/2018Document Set ID: 3846074

norrisl
Typewritten Text
Council Agenda - Agenda Item 8.2 - Attachment 3 - Advertised Plans - 15 Lamont Street Invermay
Page 2: ECM 3846074 v1 DA0276/2018 - Other Files - Attachment 2 - … · 2018-07-24 · PROPOSED NEW ANCILLERY DWELLING & DOUBLE GARAGE EXISTING RESIDENCE 100.00mm 100.177mm 100.193mm 100.228mm

6000 6000

650

0

180

0 30

00

35002410

3410

1200

BED

KITCHEN

LIVING

BATH

12270

PORCH

GARAGE

P2P1

20

00

W1 W2

W3W4

2

1

S/D

2.1H x 5.1W

ROLLER DOOR

COL

COL

SLIDING DOOR

LEGEND

S/D

COLUMN COL

PARKING SPACE 1 P1

PARKING SPACE 2P2

Drafted by: Approved by:

Scale:

Revision:

Date:

Project/Drawing no:

Drawing:

Project:

NO

TE

: D

O N

OT

SC

AL

E O

FF

DR

AW

ING

S

Client name:

Accredited building practitioner: Frank Geskus -No CC246A

10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.au

1 : 100

F.G.G.E.R.G.

PROPOSED ANCILLARYADDITION

PD18119 02

21/05/2018

PROPOSED ANCILLARYDWELLING15 LAMONT STREETINVERMAY

PLANNING

PRELI

MIN

ARY P

RIN

T

DB INVESTMENTS

03

NOTE:

FLOOR AREAS INCLUDE TO EXTERNAL FACE OF

BUILDING AND GARAGE, UNLESS OTHERWISE STATED.

DECKS AND OUTDOOR AREAS ARE CALCULATED

SEPARATELY.

1 : 100

FLOOR PLAN

NEW ANCILLARY ADDITION AREA 41.34 m2 ( 4.45 SQUARES )

NEW GARAGE AREA 41.34 m2 ( 4.45 SQUARES )

82.69 8.89TOTAL FLOOR AREA m2 ( SQUARES )

ANCILLARY ADDITION - DOOR SCHEDULE

MARK WIDTH TYPE REMARKS

1 820 INTERNAL TIMBER DOOR

2 820 INTERNAL TIMBER DOOR

ANCILLARY ADDITION - WINDOW SCHEDULE

MARK HEIGHT WIDTH TYPE REMARKS

W1 2100 2000 SLIDING DOOR

W2 1200 1810 AWNING WINDOW

W3 1800 1810 AWNING WINDOW

W4 600 910 AWNING WINDOW

ALUMINIUM AWNING WINDOWS ??? GLAZING COMPLETE

WITH FLY SCREENSTO SUIT ??? BAL RATING.

ALL WINDOW MEASUREMENTS TO BE VERIFIED ON SITE

PRIOR TO ORDERING

Version: 1, Version Date: 22/05/2018Document Set ID: 3805865

PLANNING EXHIBITEDDOCUMENTS

Planning Administration

0276/2018Ref. No: DA

Dateadvertised: 09/06/2018

This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.

Version: 2, Version Date: 07/06/2018Document Set ID: 3818249Version: 1, Version Date: 18/07/2018Document Set ID: 3846074

Page 3: ECM 3846074 v1 DA0276/2018 - Other Files - Attachment 2 - … · 2018-07-24 · PROPOSED NEW ANCILLERY DWELLING & DOUBLE GARAGE EXISTING RESIDENCE 100.00mm 100.177mm 100.193mm 100.228mm

FLOOR

CEILING

240

0

E.S.L

25.0°

5534

FLOOR

CEILING

240

0

E.S.L

40

80

5534

1 : 100

NORTHERN ELEVATION

1 : 100

EASTERN ELEVATION

Drafted by: Approved by:

Scale:

Revision:

Date:

Project/Drawing no:

Drawing:

Project:

NO

TE

: D

O N

OT

SC

AL

E O

FF

DR

AW

ING

S

Client name:

Accredited building practitioner: Frank Geskus -No CC246A

10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.au

1 : 100

F.G.G.E.R.G.

ELEVATIONS

PD18119 03

21/05/2018

PROPOSED ANCILLARYDWELLING15 LAMONT STREETINVERMAY

PLANNING

PRELI

MIN

ARY P

RIN

T

DB INVESTMENTS

03

VERANDAH ROOF CLADDING

COLORBOND CUSTOM ORB

TO CLIENTS COLOR CHOICE

ROOF CLADDING

COLORBOND CUSTOM ORB

TO CLIENTS SPECS.

WEATHERBOARD

CLADDING TO CLIENTS

SPECS

DOORS AND WINDOWS TO BE

SEALED IN ACCORDANCE WITH

NCC 2016/2 3.12.3

CONCRETE LANDING

Version: 1, Version Date: 22/05/2018Document Set ID: 3805865

PLANNING EXHIBITEDDOCUMENTS

Planning Administration

0276/2018Ref. No: DA

Dateadvertised: 09/06/2018

This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.

Version: 2, Version Date: 07/06/2018Document Set ID: 3818249Version: 1, Version Date: 18/07/2018Document Set ID: 3846074

Page 4: ECM 3846074 v1 DA0276/2018 - Other Files - Attachment 2 - … · 2018-07-24 · PROPOSED NEW ANCILLERY DWELLING & DOUBLE GARAGE EXISTING RESIDENCE 100.00mm 100.177mm 100.193mm 100.228mm

FLOOR

CEILING

240

0

E.S.L

5534

FLOOR

CEILING

240

0

E.S.L

5534

25.0°

1 : 100

WESTERN ELEVATION

1 : 100

SOUTHERN ELEVATION

Drafted by: Approved by:

Scale:

Revision:

Date:

Project/Drawing no:

Drawing:

Project:

NO

TE

: D

O N

OT

SC

AL

E O

FF

DR

AW

ING

S

Client name:

Accredited building practitioner: Frank Geskus -No CC246A

10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.au

1 : 100

F.G.G.E.R.G.

ELEVATIONS

PD18119 04

21/05/2018

PROPOSED ANCILLARYDWELLING15 LAMONT STREETINVERMAY

PLANNING

PRELI

MIN

ARY P

RIN

T

DB INVESTMENTS

03

VERANDAH ROOF CLADDING

COLORBOND CUSTOM ORB

TO CLIENTS COLOR CHOICE

ROOF CLADDING

COLORBOND CUSTOM ORB

TO CLIENTS SPECS.

WEATHERBOARD

CLADDING TO CLIENTS

SPECS

DOORS AND WINDOWS TO BE

SEALED IN ACCORDANCE WITH

NCC 2016/2 3.12.3

CONCRETE LANDING

ROOF FRAMING

PREFABRICATED ROOF TRUSSES

@ 900 CRS MAX

BRACING BY OTHERS

Version: 1, Version Date: 22/05/2018Document Set ID: 3805865

PLANNING EXHIBITEDDOCUMENTS

Planning Administration

0276/2018Ref. No: DA

Dateadvertised: 09/06/2018

This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.

Version: 2, Version Date: 07/06/2018Document Set ID: 3818249Version: 1, Version Date: 18/07/2018Document Set ID: 3846074

Page 5: ECM 3846074 v1 DA0276/2018 - Other Files - Attachment 2 - … · 2018-07-24 · PROPOSED NEW ANCILLERY DWELLING & DOUBLE GARAGE EXISTING RESIDENCE 100.00mm 100.177mm 100.193mm 100.228mm

25.0° FALL 25.0° FALL

25.0° FALL25.0° FALL

GUTTER

GUTTER

GUTTER

GUTTER

Drafted by: Approved by:

Scale:

Revision:

Date:

Project/Drawing no:

Drawing:

Project:

NO

TE

: D

O N

OT

SC

AL

E O

FF

DR

AW

ING

S

Client name:

Accredited building practitioner: Frank Geskus -No CC246A

10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.au

1 : 100

F.G.G.E.R.G.

ROOF PLAN

PD18119 05

21/05/2018

PROPOSED ANCILLARYDWELLING15 LAMONT STREETINVERMAY

PLANNING

PRELI

MIN

ARY P

RIN

T

DB INVESTMENTS

03

1 : 100

ROOF PLAN

ROOF PLUMBING NOTES:

GUTTER INSTALLATION

TO BE IN ACCORDANCE WITH

NCC 2016 PART 3.5.2.4.

WITH FALL NO LESS THAN

1:100 FOR BOX GUTTERS

1:500 FOR EAVES GUTTER

UNLESS FIXED TO METAL FASCIA

EAVES GUTTER TO BE FIXED

@ 1200 CRS MAX.

VALLEY GUTTERS ON A ROOF WITH A PITCH:

A) MORE THAN 12.5° DEGREES - MUST

HAVE A WIDTH OF NOT LESS THAN

400mm AND ROOF OVERHANG OF NOT

LESS THAN 150mm EACH SIDE OFVALLEY

GUTTER.

B) LESS THAN 12.5° DEGREES, MUST BE

DESIGNED AS A BOX GUTTER.

LAP GUTTERS 75mm IN THE DIRECTION

OF FLOW, RIVET & SEAL WITH AN

APPROVED SILICONE SEALANT.

DOWNPIPE POSITIONS SHOWN ON THIS

PLAN ARE NOMINAL ONLY.

EXACT LOCATION & NUMBER OF D.P'S

REQUIRED ARE TO BE IN ACCORDANCE

WITH NCC CLAUSE 3.5.2.5 REQUIREMENTS.

SPACING BETWEEN DOWNPIPES MUST NOT

BE MORE THAN 12m & WITHIN 1.2m FROM A

VALLEY GUTTER.

ADDITIONAL ROOF LOAD

NO SOLAR P.V. SYSTEM HAS BEEN ALLOWED FOR,

NO SOLAR HOT WATER HAS BEEN ALLOWED FOR.

METAL SHEETING ROOF TO BE INSTALLED IN

ACCORDANCE WITH NCC 2016 3.5.1.3.

REFER TO TABLE 3.5.3.1a FOR ACCEPTABLE

CORROSION PROTECTION FOR SHEET ROOFING,

REFER TO TABLE 3.5.1.2 FOR ACCEPTABILITY OF

CONTACT BETWEEN DIFFERENT ROOFING

MATERIALS.

REFER TO NCC 2016 3.5.1.3. FOR FIXING, SHEET

LAYING SEQUENCE, FASTENER FREQUENCY FOR

TRANVERSE FLASHINGS AND CAPPINGS, ANTI

CAPILLARY BREAKS, FLASHING DETAILS.

ROOF PENETRATION FLASHING DETAILS.

Version: 1, Version Date: 22/05/2018Document Set ID: 3805865

PLANNING EXHIBITEDDOCUMENTS

Planning Administration

0276/2018Ref. No: DA

Dateadvertised: 09/06/2018

This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.

Version: 2, Version Date: 07/06/2018Document Set ID: 3818249Version: 1, Version Date: 18/07/2018Document Set ID: 3846074