Two profiles available to fit: 50-100mm cavities & 100-150mm cavities Fully Rigid Plastic Cavity Closer Easy Fit Insulated Cavity Closer • Fully certificated • Meets building regulations • Available in two profiles to fit up to 150mm cavity • Minimum thermal resistance 0.967m 2 K/W • Easily cut to fit the exact cavity size • Fully rigid plastic cavity closer 50 65 75 85 100 150 115 F i v e W i d t h s i n o n e C a v i t y C l o s e r 5 T w o P r o fi l e s M a x i m u m w i d t h 1 5 0 m m 2 C u t G r o o v e s t o d e s i r e d w i d t h 100mm 85mm 75mm 65mm 50mm SILVER
2
Embed
Easy Fit Insulated Cavity Closer - YBS Insulation€¦ · Easy Fit Insulated Cavity Closer • Fully certificated • Meets building regulations • Available in two profiles to fit
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Two profiles available to fit: 50-100mm cavities & 100-150mm cavities
Fully Rigid Plastic Cavity Closer
Easy Fit Insulated Cavity Closer
• Fully certificated
• Meets building regulations
• Available in two profiles to fit up to 150mm cavity
If required, sections of Easi-Close can be jointed to minimise waste. All joints must be tightly butted -450 downwards towards the outer leaf. This will stop potential water penetration.
Corner Jointing
When jointing horizontal to vertical, trim both PVC flanges and allow the vertical to extend below the horizontal - this stops water ingress.
Measure cavity opening
Cutprofile to
required length
Measure the opening of window/door
1 2 3
Two profiles available to fit: 50-100mm cavities & 100-150mm cavities
Press the insulation side of the profile into the opening, fixing the plastic flange securely with clout nails or a grab adhesive.
5Cut insulation to required width. DO NOT CUT THE PLASTIC OUTER SHELL (2 profiles, max. cavity width 150mm)
450 65 75 85 100
150115
BDA Agrément Nr.BPD 11-304 • BPD 11-305
BPD 11-306
Minimum thermal resistance of path 2 (shortest path) - Standard
Exceeds building regulations minimum thermal resistance path of 0.45 m2K/W
The declared minimum thermal resistance for the defined cavity closer 0.930 (EPS)
Figure Path Distancemm
Material
EPS
A - B1 1,6 0,0090,170U-PVC
B1 - C1 29,0 0,9060,032XPS or
EPS
C1 - E 1,0 0,0060,170U-PVC
E - F 1,6 0,009
0,930Rmin =
0,170U-PVC
Thermalconductivity(W.m-1.K-1)
Thermal resistance(m2.K.W-1)
Easi-Close can be installedin a variety of ways:
• Tack to window frame if built in.
• Built-in as work progresses friction fitting.
• Easi-Close can be installed after the reveal has been constructed by fixing to the inner leaf using grab adhesive.